Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size...

64
Buckley Associates, Inc. Commercial HVAC Products Local Stock Catalog Serving New England with 6 Locations buckleyonline.com | (800) BUCKLEY

Transcript of Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size...

Page 1: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

Buckley Associates, Inc.

Commercial HVAC ProductsLocal Stock Catalog

Serving New England with 6 Locations

buckleyonline.com | (800) BUCKLEY

Page 2: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

2

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Manchester, New Hampshire55 Buckley CircleManchester, NH 03109(603) 669-3566(603) 669-2347 Fax

Quote Desk:[email protected]

Gorham, Maine510 Main StreetGorham, ME 04038(207) 773-0078(207) 773-0074 Fax

Quote Desk:[email protected]

Albany, New York120 Railroad AvenueAlbany, NY 12205(518) 438-7423(518) 438-5527 Fax

Quote Desk:[email protected]

Eastern New York

and Western Vermont

New Hampshire and Eastern

Vermont

Hanover, Massachusetts385 King StreetHanover, MA 02339(781) 878-5000(781) 871-9435 Fax

Quote Desk:[email protected]

Newington, Connecticut15 Progress CircleNewington, CT 06111(860) 666-0555(860) 666-3035 Fax

Quote Desk:[email protected]

Stratford, Connecticut350 Long Beach Boulevard, Unit EStratford, CT 06615(203) 380-2405(203) 380-2151 Fax

Quote Desk:[email protected]

Fairfield County CT and Westchester

County NY

Connecticut and Western

Massachusetts

Eastern Massachusetts

and Rhode Island

SALES OFFICE & WAREHOUSE SALES OFFICE & WAREHOUSE MAIN OFFICE & MANUFACTURING PLANT

SALES OFFICE & WAREHOUSE SALES OFFICE & WAREHOUSE SALES OFFICE

Buckley's Factory-Authorized Startup, Service, Calibration and Commissioning Services

Let Buckley's team of Factory-Authorized field service technicians take away the stress of equipment startup and commissioning. Our territory encompasses all of New England and Eastern New York State. We are certi-fied in a whole host of equipment including:

For Pricing and Availability:[email protected]

(781) 681-3245

Page 3: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

3

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

4 RGD Product Cross Reference5 Ceiling Diffusers8 Slot Diffusers9 Supply Registers10 Return Grilles11 Grilles & Registers14 Single Duct VAV Boxes

15 45° Air-Tite Connector16 Air-Tite Bellmouth17 Air-Tites and Spin-Ins18 Transitions19 Distribution Plenums20 Flexible Duct21 Buck Duct22 Flex Accessories & Cable Controls23 Stamped Grilles24 Louvers25 Static Fire Dampers26 Fire Dampers27 Duct Access Doors

28 Duct Access Doors and Panels29 Control Dampers 30 Backdraft Dampers32 Gasketed Spiral Pipe & Fittings34 Snaplock Pipe & Accessories35 Penthouse Elevator Louver36 Roof Curbs38 Equipment Supports

40 Direct Drive Roof Exhaust Fan42 Belt Driven Roof Exhaust Fan45 Varigreen Upblast Exhaust48 Ceiling Ventilation Fans 52 Fan Accessories54 Inline Fans58 Sidewall Propeller Fans60 Gravity Hoods61 Fume Exhaust Systems

62 Terms & Conditions of Sale

SHEET METAL PRODUCTS

AIR DISTRIBUTION PRODUCTS

THE FINE PRINT

All prices within this stock catalog are LIST PRICE. Please apply your company's discount to determine your net purchase price.Unless otherwise noted all dimensions are listed in INCHES. Prices are effective 12/1/2018.

SMW Local 17

BUCKLEYAbout Buckley Associates

MECHANICAL PRODUCTS

At Buckley our primary goal is to provide our clients with quick, efficient, and courteous customer service. This is accomplished by ensuring that our team adheres to our core business principals:

ª Maintaining a Customer Focus ª Teamwork ª Embarking on Continuous Improvement

Programs ª Adhering to Operational Excellence

To this affect we stock thousands of items across our five warehouse locations. We offer convenient pick up locations as well as daily delivery services within our service region.

Made in New England by New EnglandersBuckley maintains a 50,000 sq ft manufacturing facility in Hanover, MA. We manufacture a wide range of sheet metal products including:

ª Roof Curbs, Equipment Supports ª UL-Listed Flexible Duct and Buck Duct ª Access Doors ª Transitions and Distribution Plenums ª Stamped Grilles ª UL-Listed Static Fire Dampers ª Aluminum Louvers

Our products are manufactured by the skilled craftsmen of the Sheet Metal Workers Union Local 17. We maintain stock on many of our products but can also manufacture custom sizes or quantities to fit your needs.

Since 1970.

SHEET METAL PRODUCTS (continued)

Page 4: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

4

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Price Industries Metal*Aire Nailor Industries Titus Krueger Tuttle & Bailey

AMD 5000 6400 TDCAA 5SH AM

AMDEX 5000IV 6400IV -- -- RC/ARC

LCMD 5200D -- -- -- --

SMD 5500S 6500 TDC SH M

SMX 5500SIV 6500IV TDV SHV --

SCD 5700/5800 RNS TMS 1400 S1200

SPD 5750/5850 UNI OMNI PLQ S1100

SPDHI PHENOMENATOR -- -- -- --

RCDE 3100 RNR TMR RM1 P3

PDF 7500/7550 4320/4325 PAS 6604 PP

PDC 7600 4320CB/4325CB PCS 6504 PV

PDDR 7500R 4360/4365 PAR/PMR/PDR 6490/6690 PP

PFRF SPRTB 4302 PXP/PXP-DF 6790 PTL

APF PFTB DFA TRM 5HCF SMF

520D V4004SD 61DV/61DH 300R 880 T64

530 SRH 6145 350R S80 T70

630 RH 5145 350F S580 A70

80 CC5 51EC 50 EGC5 CRE500

LBPH 2000F -- CT-PP-O LFD 4000

530FF SRHF 61FB45 350RLF1 S80H T70DFB

STG DG 51DG CT-700L 600A A990

TBDI PHPSI 57101 TBDI PSTBSI SVPS

SDS100 6600 5010 ML-39 1910 6000

SDG 4004SP-1 -- US300/FS DMGU --

VPD-HC -- -- T3SQ -- --

SDV5 TH 3001 ESV LMHS SDV

RAC -- -- ACPT -- --

The information contained within this cross reference should be used as a "guide" when making product selections. Buckley will not be held responsible for any errors caused by its use.

RGD Product Cross Reference

Page 5: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

5

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Inlet Size CFM Panel SizeSPD31

Steel,T-BarSPD17

Steel, FinelineSPD-HI31

Steel, High InductionSCD31

Steel, T-BarVCR9 Damper

6 15712 × 12 85. -- -- 85. 22.

24 × 24 112. 112. 309. 115. 22.

8 27912 × 12 85. -- -- 85. 24.

24 × 24 112. 112. 309. 115. 24.

10 436 24 × 24 112. 112. 309. 115. 27.

12 628 24 × 24 112. 112. 309. 115. 29.

14 855 24 × 24 112. 112. -- 115. 42.

15 982 24 × 24 112. -- -- 115. --

Inlet Size CFM Panel SizeVPD-HC

T-Bar

6 157 24 × 24 1,282.

8 279 24 × 24 1,282.

10 436 24 × 24 1,282.

SPD/ASPDSquare Plaque Diffuser w/ Round Neck

SPD31

SCDSquare 3-Cone Diffuser

VPD-HCVaritherm Cooling & Heating Diffuser

CFM @ 500FPM Neck Velocity.

SCD31

Ceiling Diffusers

SMXSteel, High Induction Directional Diffuser

Size 4A CFM Panel Size

SMX3PT-Bar

VCS3Damper

TR3Transition

6 × 6 • 125 24 × 24 140. 22 23.

9 × 9 • 282 24 × 24 159. 32. 26

12 × 12 • 500 24 × 24 186. 35. 32.

15 × 15 • 781 24 × 24 234. 51. 44.

CFM @ 500FPM Neck Velocity.

CFM @ 800FPM Neck Velocity.

SPD-HI31 VCR9

Page 6: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

6

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Ceiling Diffusers

SMDSteel, Louvered Face Directional Diffuser

CFM @ 500FPM Neck Velocity.

Size 4A 3A 2G 2S 1S CFM Panel Size

T-Bar Surface Mount

VCS3Damper

TR3Transition

SMD3P

Panel

SMD17P

Fineline

pSMD1

Flat Frame

SMD6Beveled Frame

6 × 6 p 125 24 × 24 113. 156. 67. 83. 22. 23.

9 × 9 p 282 24 × 24 126. 169. 83. 96. 32. 26.

12 × 12 p 500 24 × 24 159. 199. 112. 125. 35. 32.

15 × 15 p 781 24 × 24 191. 234. 144. -- 51. 44.

18 × 18 p 1125 24 × 24 185. -- 185. -- 57. 62.

21 × 21 1531 24 × 24 288. -- -- -- 81. 68.

Size 4A CFM Panel Size

T-Bar Surface Mount

VCS3Damper

TR3Transition

pAMD3PA

Panel

AMDEX3PAHigh Induction

pAMD1

Flat Frame

6 × 6 p 125 24 × 24 177. 200. 96. 22. 23.

9 × 9 p 282 24 × 24 198. 216. 118. 32. 26.

12 × 12 p 500 24 × 24 238. 293. 158. 35. 32.

15 × 15 781 24 × 24 284. 374. 203. 51. 44.

AMD/AMDEXAluminum, Louvered Face Directional Diffuser

AMD/SMD

CFM @ 500FPM Neck Velocity.

AMDEX VCS3Damper w/ Lever

SMD6

Page 7: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

7

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size 4A 3A CFM LCMDTR3

Transition

6 × 6 • • 125 71. 23.

8 × 8 • • 222 82. 26.

10 × 10 • • 347 104. 32.

12 × 12 • • 500 115. 32.

14 × 14 • 680 135. 44.

Price includes damper. Face-screw mounting.

LCMDLight Commercial Directional Diffuser w/Beveled Frame and Damper

Size CFM PDF3

Cheese Blade T-BarPDC3

Curved Grate, T-BarVCR9Damper

6 98 89. 110. 22.

8 175 89. 110. 24.

10 273 89. 121. 27.

12 393 89. 121. 29.

14 535 89. -- 42.

PDF3/PDC3 Steel, Perforated Supply Diffuser w/ Round Neck for T-Bar Ceilings

CFM @ 500FPM Neck VelocityModel PDC3 stocked in 4-Way air pattern only.

RCDESteel, Round Diffuser

Size CFM RCDE

6 160 166.

8 280 174.

10 435 189.

12 630 210.

14 850 241.

CFM @ 800FPM Neck Velocity.

PDF3 PDC3

Ceiling Diffusers

Page 8: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

8

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Slot Diffusers

ModelSlot

Width # of Slots

CFM Range

Dimensional Data

TBDI4APF

Plaster FrameLength Height Width Inlet (Oval)

TBDI4100 1" 259-274 24 10 4 6, 8 158. 41.

78-274 48 12 4 8, 10 207. 53.

TBDI4150 1Z\x" 2 78-274 48 12 5 12 207. --

Plaster Frame Model APF is to be used for installation of slot diffuser Model TBDI in sheet rock or plaster ceilings.

TBDI4Insulated Slot Diffuser with T-Bar Mount

SDS100Linear Slot Diffuser with 1" Slot Spacing

Finish is B12 White on Frame, Black Pattern Controllers

Length# of Slots CFM Range

Surface Mount T-Bar

Plenum BDP Insulated

SDS100-2Flange Frame Concealed

MountingSDS100-14

Flush Mount SDS100-17

Fineline

24 2 32 - 256 148. 164. 164. 143.

48 1 32 - 256 -- 161. -- 169.

48 2 64 - 512 274. 245. 245. 193.

48 3 96 - 768 371. -- 324. 214.

Page 9: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

9

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size CFM 520D

6 × 4 59 72.

8 × 4 81 72.

10 × 4 104 83.

12 × 4 126 89.

14 × 4 149 89.

16 × 4 171 100.

18 × 4 194 103.

20 × 4 216 108.

24 × 4 261 125.

6 × 6 95 83.

8 × 6 132 83.

10 × 6 168 83.

12 × 6 205 92.

14 × 6 241 103.

16 × 6 277 108.

18 × 6 314 119.

20 × 6 350 125.

24 × 6 423 136.

8 × 8 182 89.

10 × 8 232 94.

12 × 8 283 108.

14 × 8 333 114.

16 × 8 383 125.

18 × 8 433 128.

20 × 8 484 141.

Size CFM 520D

24 × 8 584 164.

30 × 8 735 216.

36 × 8 886 238.

10 × 10 296 103.

12 × 10 361 116.

14 × 10 425 128.

16 × 10 489 136.

18 × 10 553 144.

20 × 10 617 152.

24 × 10 746 180.

30 × 10 938 236.

36 × 10 1131 274.

12 × 12 439 125.

14 × 12 517 130.

16 × 12 595 150.

18 × 12 673 164.

20 × 12 751 169.

24 × 12 907 200.

30 × 12 1141 269.

36 × 12 1375 305.

14 × 14 609 150.

16 × 14 701 166.

18 × 14 793 175.

20 × 14 885 191.

24 × 14 1068 222.

Size CFM 520D

30 × 14 1344 297.

16 × 16 806 188.

24 × 16 1230 238.

30 × 16 1547 333.

18 × 18 1032 222.

24 × 18 1391 269.

30 × 18 1750 358.

36 × 18 2110 419.

20 × 20 1285 258.

24 × 24 1875 358.

520DSteel, Double Deflection Supply Register with Damper

Supply Registers

SDG Steel, Spiral Duct Register

Size CFM Duct

Diameter SDG

12 × 4 788-13

176.

18 × 4 117 207.

12 × 6 117

14-21

188.

16 × 6 156 215.

20 × 6 207 235.

24 × 6 254 277.

16 × 8 24322-31

225.

24 × 8 354 289.

CFM @ 300FPM Neck Velocity.Finish is B15 Aluminum, includes air scoop.

CFM @ 500FPM Neck Velocity.

Page 10: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

10

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size CFM 530

Surface Mount

6 × 4 59 44.

8 × 4 82 44.

10 × 4 104 44.

12 × 4 127 44.

6 × 6 96 44. 69.*

8 × 6 132 44.

10 × 6 169 44.

12 × 6 205 53.

14 × 6 242 53.

24 × 6 424 72.

30 × 6 533 89.

8 × 8 183 44. 69.*

10 × 8 233 53.

12 × 8 283 53.

14 × 8 334 58.

16 × 8 383 64.

18 × 8 434 69.

24 × 8 585 78.

30 × 8 736 94.

10 × 10 297 58. 83.*

12 × 10 361 58.

14 × 10 426 64.

16 × 10 490 69.

18 × 10 554 72.

20 × 10 618 72.

24 × 10 747 80.

30 × 10 939 100.

36 × 10 1132 114.

12 × 12 439 64. 92.*

14 × 12 518 69.

16 × 12 596 72.

18 × 12 674 78.

20 × 12 752 80.

24 × 12 908 83.

30 × 12 1143 108.

36 × 12 1377 119.

*530LD (530 with Damper). CFM @ 500FPM Neck Velocity.

530Steel, 45 Degree Single Deflection Return Grille

Return Grilles

Size CFM 530

Surface Mount

48 × 12 1846 169.

14 × 14 610 72. 114.*

18 × 14 794 80.

20 × 14 886 83.

16 × 16 808 80. 128.*

18 × 16 913 89.

20 × 16 1019 92.

24 × 16 1231 100.

30 × 16 1549 125.

12 × 18 674 88

18 × 18 1033 92.

20 × 18 1225 100.

24 × 18 1393 103.

30 × 18 1752 130.

36 × 18 2111 161.

14 × 20 886 93.

20 × 20 1287 100.

24 × 20 1554 114.

30 × 20 1955 150.

Size CFM 530

Surface Mount

12 × 24 908 93.

14 × 24 1070 105.

20 × 24 1554 140.

24 × 24 1877 125.

30 × 24 2361 164.

36 × 24 2846 177.

48 × 24 3814 299.

14 × 30 1346 130.

20 × 30 1955 168.

24 × 30 2361 184.

30 × 30 2971 186.

36 × 30 3580 205.

36 × 36 4314 236.

Size CFM Panel Size530T-Bar

530L17Fineline

VCS3SDamper

APFPlaster Frame

6 × 6 96 24 × 24 119. -- 22. 64.

8 × 8 183 24 × 24 119. -- 30. 64.

10 × 10 297 12 × 12 66. -- 32. 33.

10 × 10 297 24 × 24 136. -- 33. 64.

12 × 12 439 24 × 24 139. -- 35. 64.

14 × 14 610 24 × 24 150. -- 43. 64.

16 × 16 808 24 × 24 155. -- 51. 64.

18 × 18 1033 24 × 24 166. -- 57. 64.

22 × 4 240 24 × 6 64. -- -- --

22 × 6 387. 24 × 8 69. -- -- --

22 × 8 535. 24 × 10 72. -- -- --

22 × 10 683. 24 × 12 78. 137. 46. 66.

22 × 22 1568 24 × 24 114. 171. 81. 64.

46 × 22 3339 48 × 24 247. -- -- 95.

T-Bar

Surface Mount

Page 11: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

11

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

530FF Steel, 45° Deflection Louvered Filter Grille

Size CFM 530FF

12 × 12 439 125.

16 × 16 808 166.

18 × 18 1033 180.

20 × 20 1287 191.

24 × 24 1857 227.

Filters are not included (Filter Rack is 1") CFM @ 500FPM Neck Velocity.

Size CFM STGBF

12 × 12 435 238.

18 × 12 668 263.

18 × 18 1026 355.

24 × 24 1867 560.

Finish is B15 Aluminum. This model fits in a door between 1C\," - 2Z\x" wide. (Double Frame). CFM @ 500FPM Neck Velocity.

STGBFSteel, Flat Border Door Transfer Grille withCountersunk Screw Holes

Grilles & Registers

Touch Up Paint

White Finish Aluminum Finish List Price

B12 B15 33.

For use with Price products with a B12 white finish or B15 aluminum finish.

Size CFM Panel Size 530FF

20 × 20 1287 24 × 24 197.

Surface Mount

T-Bar

CFM @ 500FPM Neck Velocity.

630 Aluminum, 45° Degree Single Deflection Return Grille

Size CFMPanel Size 630L

VCS3SDamper

APFPlaster Frame

22 × 10 683 24 × 12 91. 46. 66.

22 × 22 1568 24 × 24 145. 81. 64.

T-Bar

Size CFM 630LVCS3SDamper

6 × 6 96 55. 22.

8 × 8 183 58. 30.

10 × 10 297 65. 32.

12 × 12 439 73. 35.

14 × 14 610 84. 43.

Surface Mount

CFM @ 500FPM Neck Velocity.

CFM @ 500FPM Neck Velocity.

Page 12: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

12

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size CFM 80

No DamperVCS3SDamper

6 × 6 91 35. 22.

8 × 8 176 43. 30.

10 × 10 289 54. 32.

12 × 12 430 62. 35.

14 × 14 598 74. 43.

16 × 16 794 89. 51.

18 × 18 1018 105. 57.

24 × 24 1857 159. 102.

SizePECPlastic

AECAluminum

24 × 24 23. 74.

48 × 24 39. 147.

80 Aluminum Egg Crate Grille with 0° Deflection

AEC/PECEgg Crate

Return Grilles

Size CFM Panel Size 85

No DamperAPF

Plaster Frame

22 × 22 1150 24 × 24 168. 64.

85 Sight Resistant Egg Crate Grille with 45° Deflection

CFM @ 500FPM Neck Velocity.

CFM @ 500FPM Neck Velocity.

Size CFM Panel Size80

No DamperVCS3SDamper

APFPlaster Frame

6 × 6 91 24 × 24 110. 22. 64.

8 × 8 176 24 × 24 116. 30. 64.

10 × 10 289 24 × 24 127. 32. 64.

12 × 12 430 24 × 24 135. 35. 64.

14 × 14 598 24 × 24 151. 43. 64.

18 × 18 1018 24 × 24 180. 57. 64.

20 × 20 1270 24 × 24 196. 70. 64.

22 × 10 669 24 × 12 81. 46. 66.

22 × 22 1550 24 × 24 124. 81. 64.

46 × 22 3310 24 × 24 264. -- 95.

Surface Mount

T-Bar

RACReturn Air Canopy

Size Height Depth RAC

24 × 24 24 7 191.

LSLight Shield

Notes:

Fits Standard Grilles And Diffusers With Square And RectangularInletsShips With Legs Folded For Field Assembly To GrilleMinimum Size 6"x4" (152x102)Maximum Size 24"x24" (610x610)Factory Tolerance ± 1/32" (1)

Material: Steel Construction

Finish: B17 - Black

Submittal SheetLSLight ShieldItem Tag:RG-A-LS

All metric dimensions () are soft converted. Imperial dimensions are converted to metric and rounded to the nearest millimeter.Information within this document is subject to change without notice.

Page 1 of 1

PROJECT: 100 First Stamford Place Former Baird SUBMITTAL NO: 269152 SUBMITTAL DATE: 6/20/2018ENGINEER:  CUSTOMER: DESCRIPTION: Light ShieldLS-1-1//I/IN//24.000//24.000//5//STL///B17

© Copyright Price Industries 2018Marketing Release version: 2.18.6.1, All In One version: 3.18.6

Size Height LS

24 × 12 5 76.

24 × 24 5 95.

CFM @ 500FPM Neck Velocity.

Prevents the transfer of occupant noise into the plenum above

Minimizes direct line of sight through grille into ceiling plenum

Page 13: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

13

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

CFM @ 500FPM Neck Velocity

Ceiling Diffusers

CFM @ 500FPM Neck Velocity.

APFAluminum Plaster Frame For T-Bar Diffusers In-stalled in Sheet Rock Ceilings

PFRF3Steel, Perforated Face Return Diffuser

Size APF

12 × 12 33.

24 × 12 66.

15 × 15 61.

18 × 18 66.

24 × 24 64.

48 × 24 95.

PDDR3Steel, Perforated Return Diffuser withRound or Square Duct Connection for T-Bar Ceilings

Size CFMPFRF3

T-Bar

24 × 12 878 34.

24 × 24 1837 50.

Inlet Size CFM Panel SizePDDR

Round T-Bar

6 98 24 × 24 83.

8 175 24 × 24 83.

10 273 24 × 24 83.

12 393 24 × 24 83.

14 535 24 × 24 83.

16 698 24 × 24 109.

Inlet Size CFM Panel SizePDDR

Square T-Bar

8 × 8 222 24 × 24 104.

10 × 10 347 24 × 24 104.

12 × 12 500 24 × 24 104.

14 × 14 681 24 × 24 104.

18 × 18 1125 24 × 24 122.

22 × 10 764 24 × 12 99.

22 × 22 1681 24 × 24 87.

PDDR3 Square Duct Connection

PDDR3 Round Duct Connection

CFM @ 500FPM Neck Velocity.

Page 14: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

14

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Single Duct VAV Boxes

Inlet Size CFM Range

Dimensional Data ( H × W × L ) Model Description

VAV Box Hot Water Coil SDV5VAV Box

SEV5VAV Box, Electric

Actuator & Thermostat

SPV5* VAV Box, Pneumatic Actuator & Controller

1 Row HW CoilHGCOIL1

2 Row HW CoilHGCOIL2

6 65 - 550 8 × 12× 22Z\, 8 × 12 × 9 414. 937. 937. 324. 380.

8 125-1100 10 × 12 × 20Z\, 10 × 12 × 9 488. 1,011. 949. 329. 399.

10 210-1800 12Z\x × 14 × 20Z\, 12½ × 14 × 9 528. 1,051. 991. -- 476.

12 300-2600 15 × 16 × 20Z\, 15 × 16 × 9 568. 1,091. 1,031. -- 574.

14 430-3700 17Z\x × 20 × 23B\, 17Z\x × 20 × 9 697. 1,220. 1,161. -- 760.

16 575-5000 18 × 24 × 23B\, 18 × 24 × 9 725. 1,248. 1,188. -- 835.

* denotes that this control enables the box to be field adjusted for normally open or normally closed damper position and can operate on either a direct acting or reversing acting thermostat (supplied by others).

Single Duct Terminal Units

VAV Accessories & Replacement Parts

SDV5 Standard Construction + 22 gauge galvanized steel + ¾" fiber free insulation + Gasketed damper, mechanically sealed + Multipoint crossflow sensor + Controls enclosure + Slip and drive connection

HGCOIL1 or 2 Row Hot Water Coil

TransformerTransformer 120/277V

to 24V

List Price 74.

LMB24-3-TBelimo 24-Volt Actuator

List Price 220.

TSTATS24V Electric

T-Stat Pressure

Dependent

List Price 322.

PNEUMATIC CONTROLS Pneumatic Actuator and

Controller

List Price 463.

PICSD Controller DDC Zone Controller

Pressure IndependentMust use Transformer

List Price 902.

SDV5VAV Single Duct Box

HW Coil Standard Construction + 22 gauge galvanized steel + Copper tubes and aluminum fins with O.D.

sweat connection + Access door on top and bottom with snap

latches + Slip and drive connection

Page 15: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

15

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

45° Air-Tite Connector

Diameter

Dimensional Data3300

No Damper3300DDamper

3300D-ISGDamper w/ Insulation

Standoff Guard

3300D-HDDamper w/ Heavy Duty

Locking HandleA B C

4 9 6 10½ 32.78 34.60 43.34 --

5 11 7 10½ 33.66 38.78 47.52 63.10

6 11 7 10½ 34.70 38.78 47.52 63.10

7 13 7 10½ 39.98 42.52 53.85 66.22

8 14 8 11½ 39.98 42.52 53.85 66.22

9 15 9 11½ 52.64 60.06 70.56 84.32

10 16 10 11½ 56.22 60.06 70.56 84.32

12 18 12 11½ 65.28 81.02 91.03 104.34

14 20 14 12 84.42 96.20 106.04 119.52

16 22 16 13 105.00 111.05 126.66 141.74

3300 Buckley 45° Air Tite Connector

+ 26 Gauge galvanized steel + Neoprene gasket on flange + Flange to Flange equals + 2"

Standard Construction

+ Remote cable operator + Aluminum, stainless steel

Options

216 Top Gasketed Take Off Fitting with Damper

+ 26 Gauge galvanized steel + ¾" Wide flange with double stick neoprene gasket

Standard Construction

Diameter

Dimensional Data

216A B C D

6 6 6 ¾ 13½ 33.00

7 7 7 ¾ 14¼ 39.90

8 8 8¼ ¾ 16 39.90

9 9 9 ¾ 18¼ 90.30

10 11¼ 9½ ¾ 19 90.30

12 12 12 ¾ 22 109.80

Buckley

Page 16: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

16

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Air-Tite Bellmouth

Diameter

DimensionsBM

No DamperBMD

Damper

BMD-ISGDamper w/ Insulation

Standoff Guard

BMD-HDDamper w/ Heavy

Duty HardwareB D

4 6 7 34.10 37.58 44.18 --

5 6 8 36.90 40.70 47.30 71.30

6 6 9 36.90 40.70 47.30 71.30

7 6 10 42.06 45.92 52.52 75.92

8 6 11 42.06 45.92 52.52 75.92

9 6 12 50.40 55.56 62.16 85.56

10 6 13 50.40 55.56 62.16 85.56

12 6 15 64.90 71.80 78.40 101.80

14 6 17 69.44 76.44 83.04 --

16 6 19 81.76 90.00 96.60 --

+ 24 Gauge galvanized steel + Neoprene gasket on flange

Standard Construction

BM Buckley Bellmouth Take-Off Fitting

Diameter

DimensionsMBM

No DamperMBMDDamper

MBMD-ISGDamper w/ Insulation

Standoff GuardB C D

6 6 7 8¼ 40.60 44.36 50.96

8 6 9 10¼ 46.26 50.42 57.02

10 6 11 12¼ 55.44 60.42 67.02

MBM Buckley Mini-Bellmouth Take-Off Fitting

+ 24 Gauge galvanized steel + Neoprene gasket on flange

Standard Construction

B

ACD

Buckley

Page 17: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

17

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Air-Tites and Spin-Ins

DiameterM

No DamperATM

No DamperATMDDamper

ATMD-ISGDamper w/ Insulation Standoff

Guard RATMD

Stick on Takeoff w/ Damper

4 13.00 18.54 31.76 38.36 --

5 7.30 11.16 35.58 42.18 --

6 7.30 11.16 18.64 25.24 35.24

7 7.94 12.58 38.60 45.20 --

8 7.94 12.58 20.70 27.30 41.14

9 8.74 13.85 44.66 51.26 --

10 8.74 13.85 24.78 31.38 49.08

12 10.98 17.46 27.44 34.04 67.98

14 13.22 20.10 29.28 35.88 --

16 24.18 30.95 63.25 69.85 --

18 24.78 32.98 65.66 73.26 --

20 25.42 36.58 70.02 76.68 --

M Buckley Spin In-Collar

ATM Buckley Air Tite Connector

MNo Damper

ATMNo Damper

ATMDDamper

RATMDStick On Takeoff for Round Pipe

Standard Construction + 26 Gauge galvanized steel

Buckley

Page 18: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

18

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Transitions

Size Inlet Size TR3

6 × 6 Up to 6" 23.

8 × 8 Up to 8" 26.

9 × 9 Up to 9" 26.

10 × 10 Up to 10" 32.

12 × 12 Up to 12" 32.

15 × 15 Up to 15" 44.

18 × 18 Up to 18" 62.

20 × 20 Up to 20" 68.

21 × 21 Up to 21" 68.

22 × 22 Up to 22" 68.

24 × 24 Up to 24" 71.

6 × 9 Up to 6" 37.

6 × 12 Up to 6" 41.

9 × 12 Up to 9" 53.

9 × 15 Up to 9" 61.

10 × 22 Up to 10" 76.

12 × 15 Up to 12" 68.

12 × 18 Up to 12" 76.

12 × 24 Up to 12" 76.

15 × 18 Up to 15" 82.

+ Different depths + Aluminum construction + Black finish

Options

Model Inlet Size A BDCBTR

No InsulationDCBTR-CFw/ Duct Liner

DCBTR-FFw/ Closed Cell

DCBTR6 Up to 6" 6 6 74. 85. 96.

DCBTR9 Up to 9" 9 9 85. 108. 118.

DCBTR12 Up to 12" 12 12 101. 140. 157.

DCBTR15 Up to 15" 15 15 159. 212. 235.

DCBTR18 Up to 18" 18 18 176. 234. 262.

DCBTR21 Up to 21" 21 21 200. 266. 297.

DCBTR24 Up to 24" 24 24 210. 279. 312.

+ 26 gauge galvanized steelStandard Construction

+ Aluminum construction + Z\x" Duct liner (coated fiberglass) + C\," Closed foam cell insulation (fiber free) + Odd sizes

Options

TR3 Buckley 3" Deep Transitions

DCBTR Buckley Diffuser Boot Transition

+ 26 Gauge galvanized steel + 3" Deep base

Standard Construction

Buckley

SMW Local 17

BUCKLEY

Page 19: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

19

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Inlets are round unless specified otherwise.

Distribution Plenums

+ Remote damper operator + Price 8EC butterfly type volume control kit + C\," Fiber free insulation

Options + 24 Gauge galvanized steel + Z\x" Duct liner on insulated plenums + End caps are not insulated + Hemmed edge (concealed mounting) or flat

edge (T-Bar mounting) + Circular or oval inlets (depending on height

requirements)

Standard Construction

INTERNAL INSULATION

WHEMMED RAIL

2" INTERNAL INSULATION2"

½"

W

½"

H H

Flat Edge DetailHemmed Edge Detail

BDPBuckley Distribution Plenum with Flat or Hemmed Edge

Inlet Size Ø

List Price Add

8EC

5 --

6 146.

7 --

8 150.

9 --

10 150.

12 160.

14 --

Inlet Size/Plenum Height

BDPHPlenum with Hemmed Edge

BDPFPlenum with Flat Edge

Buckley Plenum and Price Linear Slot Diffuser with Remote Cable Operator

Call for Pricing

Length

Width Up to 1C\v" 1M," - 3Z\x" 3B," - 5Z\v" 5C," - 7"# of Slots 1 2 3 4

24Bare 83. 105. 108. 123.

Insulated 116. 143. 145. 169.

36Bare 106. 129. 135. 164.

Insulated 145. 173. 185. 216.

48Bare 120. 145. 161. 185.

Insulated 169. 193. 214. 246.

60Bare 149. 185. 199. 214.

Insulated 201. 246. 264. 285.

72Bare 201. 245. 251. 273.

Insulated 266. 311. 333. 374.

Buckley

SMW Local 17

BUCKLEY

Page 20: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

20

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Flexible Duct

Buckley Flexible Duct

Atco and Industrial Flexible Duct

Atco 036 Atco 070U-LOK 100

3/3P 3M 4/4P 4M

Model DescriptionR

Value

Diameter/ List Price

3 4 5 6 7 8 9 10 12 14 16 18 20 24

Type 3 - High Pressure, Reinforced Trilaminate Core

3 Bare -- 2.59 2.81 3.00 3.52 3.98 4.46 4.80 5.68 6.68 8.16 11.84 14.02 16.64 19.30

3PInsulated w/ Polyethylene

Jacket 6.0 -- 6.25 6.54 6.92 8.02 8.15 9.08 9.84 11.46 13.88 20.16 22.32 -- --

3MInsulated w/ Aluminum

Jacket 6.0 -- -- 8.10 8.10 9.86 9.86 11.80 11.80 12.68 15.58 -- -- -- --

Type 4 - High Pressure, Vinyl Coated Fiberglass Cloth

4 Bare -- 4.55 5.02 5.64 6.62 7.52 8.65 9.50 11.80 13.22 15.92 20.96 25.52 27.46 32.70

4PInsulated w/ Polyethylene

Jacket6.0 -- 8.44 10.04 10.04 12.22 12.22 15.15 15.15 18.00 21.65 29.44 32.24 -- --

4MInsulated w/ Aluminum

Jacket6.0 -- -- 11.75 11.75 13.94 13.94 17.12 17.12 19.26 23.34 -- -- -- --

Model Description Box

Quantity R Value

Diameter/ List Price

4 5 6 7 8 9 10 12 14 16 18 20

Low to Medium Presure Flexible Duct

Atco 036Insulated w/

Metalized Jacket 25'

6.0 -- 90. 102. 113. 121. 138. 153. 189. 229. 265. 308. 372.

Atco 070Insulated w/ Gray Polyester Jacket

4.2 -- -- 84. -- 98. -- 123. 153. 185. 213. -- --

Industrial Flexible Duct

U-LOK 100 Dust and Fume 10' N/A 163. 206. 211. -- 271. -- 337. 440. -- -- -- --

Prices are per foot and sold in lengths of 25'. Custom lenghts available.

Prices are per box.

UL181 Class 1 Air Duct

Buckley

UL181 Class 1 Air Duct

Page 21: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

21

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Triple Lock Buck Duct Hospital Grade Acoustical Low-Pressure Buck Duct

+ Single Wall + Flexible

+ Single Wall + Flexible

+ Triple Lock, Mechanical Joint + Flexible

Buckley Buck Duct

Model Description R

Value Length

Diameter/ List Price

3 4 5 6 7 8 9 10 12 14 16 18 20

Buck Duct - High Pressure, Reinforced Aluminum Core

BD Bare -- 10' 25. 32. 39. 50. 60. 68. 80. 95. 125. 142. 229. 285. 295.

BDIPInsulated w/ Polyethylene

Jacket 6.0 10' -- 83. 93. 110. 130. 132. 155. 184. 217. 244. 348. 402. --

BDIMInsulated w/ Aluminum

Jacket 6.0 10' -- -- 108. 125. 146. 148. 176. 205. 239. 268. -- -- --

Buck Duct Acoustic -Low Pressure, Perforated Aluminim Core

BDAPInsulated w/ Polyethylene

Jacket 6.0 10' -- -- 100. 120. 140. 146. 170. 202. 241. 271. 393. -- --

BDAMInsulated w/ Aluminum

Jacket 6.0 10' -- -- 123. 140. 162. 164. 197. 226. 261. 290. -- -- --

Buck Duct Acoustic - Hospital Grade Low Pressure

BDAHGPInsulated w/ Polyethylene

Jacket6.0 10' -- -- 108. 130. 151. 158. 184. 218. 260. 293. 424.

----

BDAHGMInsulated w/ Aluminum

Jacket6.0 10' -- -- 131. 150. 173. 176. 211. 242. 280. 312. --

----

Acoustical Low-Pressure Buck Duct

BDSHGHospital Grade Silencer

+ Double Wall + Outer Shell Triple Lock

Buck Duct

+ Double Wall + Outer Shell Triple Lock

Buck Duct + Polyethylene Jacket

Buck Duct Silencers

BDSSilencer

Model DescriptionR

Value Length

Diameter/ List Price

5 6 7 8 9 10 12 14 16

High Pressure, Perforated Aluminim Core

BDS Silencer 6.0 5' 190. 224. 269. 269. 375. 375. 443. 498 710.

10' 279. 330. 396. 396. 552. 552. 651. 732. 1,044.

BDSHGHospital Grade

Silencer6.0

5' 197. 231. 277. 277. 386. 386. 457. 513. 752.

10' 289. 340. 408. 408. 568. 568. 672. 754. 1,106.

Buckley Buck Duct

SMW Local 17

BUCKLEY

SMW Local 17

BUCKLEY

Page 22: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

22

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Heavy Duty Cable Ties

+ Series 56, >\zn" band, plated B\zn hex head swivel action screw and bridge, worm drive swivel action.

Stainless Steel Clamps

Mechanical Cable Tie Tool

Stainless Steel Clamps & Cable Ties

Model Description Qty List Price

SS8 Stainless Steel Clamp, 5-8" Diameter EA 5.52

SS12 Stainless Steel Clamp, 9-12" Diameter EA 8.15

DDN36 Plastic Cable Ties, Up to 11" Diameter 50 34.20

DDN48 Plastic Cable Ties, 15" Diameter 50 70.20

DIT-3 Mechanical Cable Tie Tool EA 103. + Rated up to 175lbs, Length 36" (DDN36), 48" (DDN48). Available in White.

+ Heavy duty installer controlled tool for use in the field.

Model Price

Casing/WireSocket Wrench 6' 10'

270-275B 116.35.

WIRE 6' 57.

WIRE 10'32.

030-12270-301B 139.

Diameter 5020 RAD

6 137. 165.

8 144. 165.

10 163. 168.

12 166. 172.

270-275 270-301

Cable Control ProductsBowden Remote Cable Controls and Accessories

Socket Wrench

Cable Controller Ceiling Bracket and Cover Plate

5020Round Cable Control

DamperRadial Damper w/

5' Flexible Steel Shaft

RAD

Flex Accessories & Cable Controls

RBDR-50Round Remote Powered Balancing Damper w/ Quick Control Remote

+ Available in sizes 4-24" + Available from Greenheck + On a 5-day quick build from

Greenheck

Page 23: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

23

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Stamped Grilles

Stamped Grilles Rectangular

Stamped Grilles Square

Stamped Grilles Round

Buckley Custom Stamped Grilles

Z\v, C\,, Z\x, B\,, C\v, ZC\zn, M\,, 1

SQUARE HOLES

ROUND HOLES

Z\v, B\zn, C\,, Z\x, B\,, C\v, 1

RECTANGULAR HOLES

Z\v × 1, Z\v × 2, Z\v × 3

Galvanized Steel: 10 GA...................................... List × 1.3512 GA...................................... List × 1.1014 GA...................................... List Price16 GA...................................... List × 0.9518 GA...................................... List × 0.90

Aluminum: .040......................................... List × 1.15.063......................................... List × 1.30.090......................................... List × 1.45.125......................................... List × 2.00

Stainless Steel: Available From Factory

SIZES

Up to 48 × 36 single piece construction. No limit on multiple sections.

SCREW HOLES

As required, countersunk available.

FINISHES

White or Bronze Aluminum

ADDITIONAL OPTIONS

+ Sleeves welded to faceplate + Burglar Bars welded in sleeve + Dampers mounted in sleeve + Rear angle bars for field welding

Contact Us for Pricing

Size 18 24 30 36 48

12 168. 224. 281. 337. 449.

18 252. 337. 421. 505. 673.

24 450. 562. 674. 898.

30 702. 842. 1,124.

36 1,010. 1,347.

+ $90. Minimum NET Charge

+ For prices not shown, use next highest size

+ Powder Coat Finishes AvailableContact Us for Pricing

CONSTRUCTION

Pricing Notes

Buckley

SMW Local 17

BUCKLEY

Page 24: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

24

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Louvers

+ Insect screen + Powder coat finishes

available + Custom sizes available

Contact Us for Pricing

Options

When ordering the first dimension is WIDTH (blade length) and the second dimension is HEIGHT.For pricing sizes that are not shown use the next largest size. For sizes larger than what is shown, use multiple sections.

Width

Heig

ht

12 16 20 24 28 32 36 40 48 52 56 60 64 68 72

12 226. 239. 246. 261. 248. 280. 350. 355. 459. 479. 489. 544. 558. 569. 584.

16 257. 279. 282. 292. 324. 372. 444. 479. 515. 532. 550. 567. 584. 601.

20 326. 374. 357. 478. 516. 594. 635. 656. 675. 722. 744. 766. 789.

24 392. 410. 524. 567. 632. 673. 678. 698. 763. 787. 809. 842.

28 526. 558. 628. 654. 695. 700. 726. 814. 852. 879. 904.

32 610. 720. 734. 789. 805. 860. 890. 1,006. 1,041 1,072.

36 801. 832. 886. 922. 1,018. 1,040. 1,097. 1,134. 1,192.

40 865. 939. 968. 1,069 1,092 1,152. 1,189. 1,255.

48 1,141. 1,179. 1,216 1,324. 1,372. 1,420. 1,440.

52 1,227. 1,276. 1,390. 1,440. 1,488. 1,539.

56 1,464. 1,516. 1,566. 1,620. 1,670.

60 1,569. 1,648. 1,689. 1,745.

64 1,718. 1,760. 1,820.

68 1,840. 1,906.

72 2,130.

+ Mill or bronze finish + Birdscreen + Sizes undercut by ¼"

Standard Construction

EAL Buckley Extruded Aluminum Louvers

2" 4" 4"

EAL22" Blade

EAL44" Blade

EAL4DB4" Drainable Blade

Model

Mill Finish Bronze Finish

Minimum SizeNo Flange 1" Flange No Flange 1" Flange

EAL2 -- List × 1.15 -- List × 1.35 8 × 6

EAL4 List Price List × 1.20 List × 1.20 List × 1.40 8 × 8

EAL4DB List × 1.10 List × 1.30 -- -- 8 × 8

Buckley

SMW Local 17

BUCKLEY

Page 25: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

25

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

These fire dampers are for use in static systems only. Width and Height are in inches (blades parallel to width, custom sizes available.Fire Dampers must be ordered WIDTH x HEIGHT.

Model1½-Hour Underwriters Laboratory Classified

Fire Damper

Pricing Sizes Available

Vertical Horizontal Minimum Maximum

150A Low profile type “A” damper List Price List × 1.20 6 × 4 48 × 48

150B High-hat type “B” damper List × 1.20 List × 1.40 6 × 4 48 × 43

150C 100% free area List × 2.50 List × 2.70 3 26

Static Fire Dampers

Width (Inches)

Heig

ht (I

nche

s)

6 8 12 16 20 24 28 32 36 40 44 48

6 48. 54. 54. 60. 74. 81. 92. 99. 101. 108. 118. 123.

8 54. 54. 65. 74. 83. 98. 101. 108. 120. 123. 129.

12 65. 81. 89. 93. 105. 110. 120. 129. 135. 146.

16 92. 96. 105. 120. 128. 132. 141. 149. 165.

20 108. 123. 129. 138. 147. 156. 173. 180.

24 129. 146. 153. 167. 174. 185. 198.

28 153. 177. 192. 204. 221. 234.

32 198. 222. 239. 255. 270.

36 251. 270. 290. 309.

40 290. 309. 327.

44 327. 348.

48 366.

150Buckley Static Fire Dampers - 1½ Hr Rated

150ABlades Completely In Air

Stream

150B Blades Out Of Air Stream

150C Round

$50. Minimum NET Charge

No. R9491

Buckley

SMW Local 17

BUCKLEY

Page 26: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

26

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size

Mounting Positions

S3/FDTRH V

4 ● ● 98.

5 ● ● 99.

6 ● ● 99.

7 ● ● 104.

8 ● ● 104.

9 ● ● 108.

10 ● ● 108.

12 ● ● 116.

14 ● ● 157.

16 ● 190.

18 ● 231.

Model Degree FL

165A 165° 9.

212A 212° 10.

286A 286° 27.

386A 386° 31.

FL165D* 165° 15.

FL212D* 212° 19.

*For Use with Greenheck Fire Dampers.

S3/FD-TR True Round Static Fire Damper - 1½ Hr Rated

SL2000N Ionization Smoke Detector

Universal Voltage: 230 VAC, 115 VAC, 24 VAC, 24VDC.

Model DescriptionList

Price

SL2000N Ionization Smoke Detector 446.

STS-2.5 Sampling Tube for Duct Width 6" - 30" 32.

STS-5.0 Sampling Tube for Duct Width 30" - 60" 37.

FLReplacement Fusible Links

Fire Dampers

When moisture collection is a problem in duct work or a drain pan, a moisture drain is an economical and fast way of installing a leakproof drain.

Model Description List Price

DRAINFITTING C\v" Moisture Drain 117.

DRAINCAP C\v" Cap 18.

Moisture Fitting & Drain Cap Geocel Tripolymer

SealantModel Description List Price

DM2300Gray 22.34

Clear 23.84

Model FD-TRSizes 16-18

Model S3Sizes 4-14

No. R6591/S3No. R8218/FD-TR

Page 27: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

27

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Size

Dimensional Data

C10Cam

H10Hinge

C10HPHigh PressureWidth Height

Duct Opening

6 × 6 6Z\v 6Z\v 5Z\v × 5Z\v 37.28 39.00 48.44

8 × 8 8Z\v 8Z\v 7Z\v × 7Z\v 40.08 42.10 51.30

10 × 10 10Z\v 10Z\v 9Z\v × 9Z\v 43.08 45.22 53.84

12 × 12 12Z\v 12Z\v 11Z\v × 11Z\v 46.40 49.20 58.00

16 × 12 16Z\v 12Z\v 15Z\v × 11Z\v 65.10 72.00 85.28

18 × 12 18Z\v 12Z\v 17Z\v × 11Z\v 80.92 88.50 105.98

14 × 14 14Z\v 14Z\v 13Z\v × 13Z\v 62.66 68.90 81.44

16 × 16 16Z\v 16Z\v 15Z\v × 15Z\v 65.78 72.10 85.52

18 × 18 18Z\v 18Z\v 17Z\v × 17Z\v 74.34 81.34 95.66

20 × 20 20Z\v 20Z\v 19Z\v × 19Z\v 84.88 91.66 110.34

24 × 24 24 24 23 × 23 100.18 102.95 137.96

24 × 12 24Z\v 12Z\v 23Z\v × 11Z\v 85.00 90.10 103.68

For sizes larger than 36x24 use Model WIAD.

+ Aluminum construction + #304 stainless steel + Retainer chain + Plexiglas port (single/double pane) + Custom sizes

Options

+ 24 Gauge galvanized steel frame and door + 1" Thick, double wall door with ¾" insulation + Polyethylene foam gasket on frame/door

Standard Construction

Duct Access Doors

Buckley Access Doors Cam and Hinged Latches

AD14Cam Press On Access Door

+ 24 Gauge galvanized steel frame and door

+ 1" Thick high density fiberglass insulation

Standard ConstructionSize Width Height

Duct Opening AD14

6 × 6 6Z\v 6Z\v 5Z\v × 5Z\v 49.30

8 × 8 8Z\v 8Z\v 7Z\v × 7Z\v 53.40

10 × 10 10Z\v 10Z\v 9Z\v × 9Z\v 64.48

12 × 12 12Z\v 12Z\v 11Z\v × 11Z\v 71.98

14 × 14 14Z\v 14Z\v 13Z\v × 13Z\v 84.04

Buckley

C10BPPlexiglas Port Option

C10HPHigh Pressure Option

H10Hinged Access Door

C10Access Door with Cam Latches

SMW Local 17

BUCKLEY

Page 28: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

28

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Duct Access Doors and Panels

Size LAD

10 × 6 102.

12 × 8 141.

18 × 14 277.

24 × 18 321.

Door SizeDuct

Diameter LRAD

8 × 4 5 - 6 109.

8 × 4 7 - 9 109.

8 × 4 10 - 12 109.

8 × 4 13 - 14 109.

LADRectangular Sandwich Access Door

LRADRounded Sandwich Access Door

Door Size Rough Opening # of Latches BNTC

8 × 8 8Z\v × 8Z\v 1 63.

12 × 12 12Z\v × 12Z\v 1 82.

14 × 14 14Z\v × 14Z\v 1 96.

16 × 16 16Z\v × 16Z\v 1 111.

18 × 18 18Z\v × 18Z\v 2 129.

24 × 24 24Z\v × 24Z\v 4 175.

+ 16 Gauge door, 16 gauge mounting frame + 1" Exposed flange + Concealed spring pin hinge + Screwdriver operated cam latch(es)

+ .25" Mounting holes within fame + Gray baked on powder coat

BNTC Drywall Access Panel

Standard Construction

+ 24 Gauge galvanized steel door + .060 Extruded aluminum frame + 1"Thick, fiberglass insulation + Polyethylene foam gasket

Standard Construction

Size WIAD

18 × 36 542.

18 × 48 631.

18 × 60 708.

18 × 72 819.

24 × 36 596.

24 × 48 695.

24 × 60 794.

30 × 72 933.

36 × 60 830.

36 × 72 938.

+ Aluminum construction + Additional handles + Plexiglas port (single/double pane) + Custom sizes

Options

Sizes shown are "duct opening" and are exact. (Width × Height).

WIADBuckley Walk-in Access Doors

Buckley

Page 29: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

29

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Control Dampers

Size Actuator Damper

Single Blade

10 × 6 248.

12 × 6 248.

8 × 8 248.

10 × 8 248.

12 × 8 248.

14 × 8 258.

16 × 8 258.

18 × 8 263.

20 × 8 263.

24 × 8 277.

Opposed Blade

10 × 10 248.

12 × 10 248.

14 × 10 258.

16 × 10 258.

18 × 10 263.

20 × 10 263.

24 × 10 277.

TFB LF NFBUP/S

Model Usage Actuator

Actuator with End Switch

24V or 120V

TFB

18 inch-lb for damper areas up to 5.5 sq ft.

455.TFB24 / TFB120

537.TFB24S / TFB120S

LF

35 inch-lb for damper areas up to 8.5 sq ft.

520.LF24 / LF120

606.LF24S / LF120S

pNFBUP

60 inch-lb for damper areas up to 22 sq ft.

639.NFBUP

814.NFBUPS

Size Actuator Damper

6 283.

8 294.

10 312.

12 324.

14 347.

16 362.

18 398.

Size Actuator Damper

30 × 20 416.

36 × 20 433.

40 × 20 448.

22 × 22 428.

24 × 24 428.

30 × 24 459.

36 × 24 482.

42 × 24 488.

48 × 24 536.

26 × 26 496.

28 × 28 496.

30 × 30 573.

36 × 30 588.

48 × 30 p 669.

32 × 32 p 573.

36 × 36 p 661.

48 × 36 p 738.

48 × 48 p 931.

Belimo Actuators

VCD23 Single/Opposed Blade Control Damper

VCDR53 Round Volume Control Damper

Size Actuator Damper

30 × 10 295.

36 × 10 315.

12 × 12 248.

14 × 12 258.

16 × 12 258.

18 × 12 263.

20 × 12 263.

22 × 12 277.

24 × 12 277.

30 × 12 295.

36 × 12 315.

48 × 12 344.

14 × 14 295.

16 × 14 295.

18 × 14 311.

20 × 14 311.

22 × 14 323.

24 × 14 323.

30 × 14 336.

Size Actuator Damper

36 × 14 363.

48 × 14 395.

16 × 16 295.

18 × 16 311.

20 × 16 311.

22 × 16 323.

24 × 16 323.

30 × 16 336.

32 × 16 336.

36 × 16 363.

48 × 16 395.

18 × 18 372.

20 × 18 372.

24 × 18 395.

30 × 18 416.

36 × 18 433.

48 × 18 498.

20 × 20 372.

24 × 20 395.

Hand Quadrant

2" Insulation Standoff

Model List Price

Jump Over Bracket 163.

Hand Quadrant 21.

Replacement Shaft Key 60.

2" Insulation Stand Off 7.

Replacement Shaft Key

809735

+ Need A Custom Size? We can cut down the width on any VCD23 damper to make a custom size. NET Price Add $80.00 up to 24 × 24. $100 for larger sizes.

+ 1" Flange add List Price x 1.25

Jump Over Bracket

879586Join more than

one damper 10" or larger

Page 30: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

30

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Backdraft Dampers

Model BDD WD100 WD320

For Use With Stock Models

SQ, BSQ G, GB, GRS, CUBE SE-1

Mounting Position

Vertical Horizontal Vertical

Airflow Direction

Horizontal Vertical Up Horizontal

Flange Optional - Add 25% No Yes

Damper Motor Kit 120V / 24V

Not Stocked 214.120V

394.24V

--

8 × 8 87. 139. --

12 × 8 102. -- --

10 × 10 102. 162. 215.

12 × 12 106. 165. 215.

18 × 12 135. -- --

24 × 12 146. -- --

14 × 14 123. -- 255.

16 × 16 138. 190. --

18 × 18 162. 220. 255.

24 × 18 182. -- --

20 × 20 182. -- --

24 × 24 230. 241. --

30 × 30 -- 263. --

BDD WD100 WD320

BDD, WD100, WD320 Backdraft Dampers

Model RSK

For Use With Stock Models

FG

Mounting Position

Vertical Or Horizontal

Airflow Direction

Vertical Or Horizontal

Flange No

4" 48.

5" 58.

6" 61.

8" 88.

10" 160.

12" 151.

RSK

Page 31: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

damper diversity.More choices for more air applications.

Greenheck’s damper line includes much more than our

industry-leading life safety and commercial control dampers.

We are also a major supplier of air measuring dampers and

heavy-duty industrial dampers with capacities to 45+ in. wg

and heat tolerance of 1000˚+ F. Plus, our design and application

engineers will work with you to create energy-efficient damper

solutions for virtually any application.

You can count on Greenheck dampers for top performance —

whether you’re specifying airflow control for HVAC applications

or industrial processes — thanks to third-party certifications

such as AMCA, ANSI, ASHRAE, UL and ISO9001 (for industrial

dampers). Our multiple U.S. manufacturing locations and Quick

Delivery program ensure quick, on-time delivery to the job site.

All good reasons to make Greenheck your single source

for all the dampers you specify.

Learn more at greenheck.com/4dampers

Fans | Energy Recovery | Packaged Ventilation | Make-up Air

Kitchen Ventilation | Lab Exhaust | Dampers | Louvers | Coils

715.359.6171greenheck.com

©20

17 G

reen

heck

• Fire dampers• Smoke dampers• Fire/smoke dampers• Control• Isolation/Bubble-Tight• Gravity• Blast• Tornado• Nuclear• Tunnel transit

• Low-rise, high-rise buildings

• Factories• Nuclear power plants• Oil and gas refi neries• Cooling towers• Government buildings• Mining• Transit smoke exhaust

DAMPER TYPES

DAMPERS

APPLICATIONS

NEW!

Rectangular Bubble-Tight Damper

Page 32: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

32

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Gasketed Spiral Pipe & Fittings

SPSpiral Pipe

PCPTMale Coupling

CPL-MNGNon Gasketed Male

Coupling

PECT (4"-12")ECT (14"-24")

End Cap

PE90T (4"-12") 1½ RadiusE90T (14'-24") 1½ RadiusPE90T1 (6"-12") 1 RadiusE90T1 (14"-18") 1 Radius

90° Elbow

PE45T (4"-12")E45T (14"-20")

1½ Radius45° Elbow

DTVolume Damper

PBT (6"-12")CTOT (14"-18")

Bellmouth

CPLFNon Gasketed Female

Coupling

Model

Diameter/ List Price

3 4 5 6 7 8 9 10 12 14 16 18 20 22 24

SPSpiral Pipe

45. 57. 70. 82. 94. 107. 120. 133. 158. 183. 208. 232. 257. 282. 311.

PCPTMale Coupling

-- 24. 25. 26. 28. 30. 32. 36. 40. 44. 51. 55. 59. 63. 67.

CPLFNon Gasketed

Coupling-- 14. 15. 17. 20. 21. 22. 24. 28. 31. 39. 42. 45. 49. 53.

CPL-MNGNon Gasketed

Coupling-- 22. 21. 21. 23. 25. 26. 28. 33. 36. 45. 49. 52. 57. 62.

PECTEnd Cap

-- 35. 36. 39. 43. 43. 48. 48. 53. -- -- -- -- -- --

ECTEnd Cap

-- -- -- -- -- -- -- -- -- 73. 83. 94. 102. 110. 120.

PE90T90° Elbow 1Z\x Radius

-- 55. 64. 64. 76. 85. 94. 111. 149. 229. 265. 329. 418. 477. 559.

PE90T190° Elbow 1 Radius

-- -- -- 63. -- 90. -- 125. 150. 219. 253. 314. -- -- --

PE45T45° Elbow

-- 43. 48. 45. 54. 58. 73. 73. 88. -- -- -- -- -- --

E45T45° Elbow

-- -- -- -- -- -- -- -- -- 138. 157. 185. 234. -- --

DTVolume Damper

-- 80. -- 102. -- 104. -- 124. 147. 173. 184. 194. -- -- --

PBTBellmouth

-- 36. 39. 41. 45. 45. 47. 49. 51. -- -- -- -- -- --

CTOTBellmouth

-- -- -- -- -- -- -- -- -- 148. 173. 198. -- -- --

Page 33: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

33

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

SizeT

Tee

4 to 4 96.

6 to 6 108.

8 to 8 124.

10 to 10 130.

14 to 14 169.

SizePTFC

Saddle Tap

4 to 6 35.

6 to 8 40.

6 to 10 40.

8 to 10 46.

6 to 12 40.

8 to 12 46.

10 to 12 49.

8 to 14 47.

10 to 14 49.

12 to 14 61.

10 to 16 49.

12 to 16 61.

SizePRD/RDT

Reducer

6 to 4 67.

8 to 6 72.

9 to 7 78.

10 to 6 77.

10 to 8 77.

12 to 8 82.

12 to 10 82.

14 to 8 131.

14 to 10 124.

14 to 12 135.

16 to 10 142.

16 to 12 143.

16 to 14 148.

18 to 12 159.

18 to 14 159.

18 to 16 165.

20 to 18 192.

Gasketed Spiral Pipe & Fittings

PRDT (4"-12")RDT (14"-20")

Reducer

PFTCT (4"-12")FTCT (14"-20")

Saddle Tap

PTT (4"-8")TT (10"-24")

Tee

Spiral Accessories

Model Description List Price

818263 Wire Rope Cutter 135.

302041/8" Wire RopeSpool of 500’

323.

CL18Cable LockBag of 10

81.

818263Wire Rope

Cutter

302041/8" Wire RopeSpool of 500’

CL18Cable LockBag of 10

Page 34: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

34

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

The Quick-Sleeve is a band-clamp connection that provides a simple, leak-free connection for round ducts.

Model Diameter QS

QS4GA 4 63.

QS5GA 5 64.

QS6GA 6 70.

QS8GA 8 76.

QS10GA 10 83.

QS12GA 12 94.

QSQuick Sleeve Clamp

Diameter

Dimensional Data

BGFA B C

3 4.25 5.63 2.25 38.

4 5.13 6.75 2.44 39.

5 6.13 8.13 2.69 52.

6 7.13 10.00 2.75 67.

8 9.25 12.00 3.38 109.

10 11.38 14.38 3.63 210.

12 13.38 16.25 3.63 229.

BGF Blast Gate, Full Gate Style

Snaplock Pipe & Accessories

Snaplock Pipe is sold in 5 foot sections.

DiameterSL

Snaplock PipeEL90

90° ElbowPSTOPEnd Cap

PTTee

4 21.00 8.30 -- --

6 26.76 8.16 20.25 36.56

8 34.98 11.24 22.88 41.66

10 43.05 18.26 27.38 70.10

12 50.64 22.58 33.56 94.70

14 63.05 30.74 37.88 118.76

16 93.00 48.20 45.70 --

SizePREDReducer

5 to 4 24.48

6 to 4 27.82

6 to 5 27.82

7 to 6 30.54

8 to 6 32.38

8 to 7 32.38

9 to 7 42.74

9 to 8 42.74

10 to 6 39.24

10 to 8 39.24

10 to 9 39.24

12 to 8 41.36

12 to 10 41.36

14 to 10 59.14

14 to 12 59.14

16 to 12 63.28

16 to 14 63.28

SLSnaplock Pipe

EL9090° Elbow

PSTOPEnd Cap

PTTEE

PREDReducer

Page 35: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

35

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Penthouse Elevator Vent

The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door and a low leakage opposed blade control damper with either a 24VAC or 120 volt actuator. The unit is provided with weather hood(s) to help minimize wind driven rain and snow infiltration. The unit is shop assembled and shipped loose from the curb.

Model

Dimensional Data Curb Hood

PELV-100A B C Size (O.D.) Qty Free Area (Ft2)

PELV-100-32-1 32 24C\v 36 31Z\x × 31Z\x 1 3.0 5,964.

PELV-100-32-2 32 24C\v 36 31Z\x × 31Z\x 2 6.0 6,840.

PELV-100-38-1 38 24C\v 36 37Z\x × 37Z\x 1 3.6 6,264.

PELV-100-38-2 38 24C\v 36 37Z\x × 37Z\x 2 7.2 7,433.

PELV-100-44-1 44 24C\v 36 43Z\x × 43Z\x 1 4.2 7,266.

PELV-100-44-2 44 24C\v 36 43Z\x × 43Z\x 2 8.4 8,647.

PELV-100Buckley Penthouse Elevator Vent

+ 36" High Model GPI Galvanized Roof Curb + Control Damper w/ mounted Actuator (Fail Open) + Aluminum Hood(s) w/ Stamped Grille in Opening

Standard Construction

Options + Tempered Glass Panel

List Price 142. + Pitched Roof Curb, Model GPIP + Powder Coat Finishes Available

Contact Us for Pricing

Buckley

SMW Local 17

BUCKLEY

Page 36: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

36

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

+ BRC200: Step height required + GPIP: Pitch per 12" required + Pricing a rectangular size:

Length + Width ÷ 2 = Size Equivalent + 10%

GPIStraight, 2" Flange

BRC20045° Cant Step

BRC30045° Cant

GPIPPitched, 2" Flange

KE100Kitchen Exhaust Curb

2" Flange

BCA100Curb Adapter

Pricing Notes

Roof Curbs

SizeGPI

Straight, 2" FlangeBCA100

Curb AdapterBRC200

45° Cant StepBRC30045° Cant

GPIP Pitched, 2" Flange

KE100 Kitchen Exhaust Curb

2" FlangeDamper Tray

Model DT

½" Burglar Bars*

17 277. 227. 629. 568. 435. -- 78. 238.

19 293. 240. 665. 600. 460. 606. 78. 238.

22 319. 293. 724. 654. 500. 727. 78. 238.

30 395. 367. 897. 810. 620. 968. 118. 396.

34 447. 425. 1,014. 916. 702. 1,108. 118. 514.

40 517. 480. 1,175. 1,060. 812. 1,272. 118. 680.

46 554. 515. 1,258. 1,136. 870. 1,365. 156. 890.

52 780. 710. 1,770. 1,599. -- 1,864. 156. 1,285.

58 841. 782. 1,909. 1,724. -- 2,060. 156. 1,388.

64 921. 865. 2,090. 1,888. -- -- -- 1,522.

Pricing

*Price for mounting in curb model selected

Buckley

SMW Local 17

BUCKLEY

ARC-200Acoustic Roof Curb

BRC100-DPDouble Pitched Roof

Curb

Additional Options Available

Page 37: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

37

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Roof Curbs

Size

GPI BRC200/BRC300 KE100

A B A B A B

17 16 20 16 24 -- --

19 18 22 18 26 18½ 22½

22 21 25 21 29 21½ 25½

30 29 33 29 37 29½ 33½

34 33 37 33 41 33½ 37½

40 39 43 39 47 39½ 43½

46 45 49 45 53 45½ 49½

52 51 55 51 59 51½ 55½

58 57 61 57 65 57½ 61½

64 63 67 63 71 63½ 67½

Models GPI, GPIP, BRC200,300 + 18 Gauge galvanized steel + 12" Height + Wood nailer + 1" Thick, 3 lb. fiberglass insulation

Standard Construction

+ Aluminum construction + Pressure-treated wood nailer + 24 Gauge galvanized steel liner + Heights larger than 12" + Burglar bars + Custom sizes + Different size flanges + Acoustic baffles

Options

BRC300/BRC200GPI

GPIP

Kitchen Exhaust Curb, Model KE100 + 18 Gauge galvanized steel + 18" Height + Vented on four sides

Curb Adapter, Model BCA100 + 18 Gauge Galvanized Steel

BCA100/ KE100

Dimensional Data

Buckley

Page 38: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

38

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Equipment Supports

Width List Price

4 List Price

6 List × 1.20

8 List × 1.30

FORM NO. 8232E(White Color) © 2002 Vent Products Co., Inc. (CD) Printed in U.S.A. SUPERSEDES FORM NO. 8232D

T

H

CONCRETE DECKSTEEL DECK

FLASHING CAP

¾" CLEARANCE FORROOFING FELTS

2"

Length

ES100 ES200 ES300

Height Height Height

< 12" < 24" < 12" < 24" < 12" < 24"

24 358. 501. 465. 651. 465. 651.

36 405. 567. 527. 738. 527. 738.

48 425. 595. 553. 774. 553. 774.

60 531. 743. 690. 966. 690. 966.

72 637. 892. 828. 1,159. 828. 1,159.

84 744. 1,041. 967. 1,354. 967. 1,354.

96 850. 1,190. 1,105. 1,547. 1,105. 1,547.

120 1,062. 1,484. 1,380. 1,932. 1,380. 1,932.

144 1,275. 1,785. 1,657. 2,320. 1,657. 2,320.

T

H

4"

CONCRETE DECKSTEEL DECK

3"

R

DECK INSULATIONBY OTHERS

FLASHING CAP

¾" CLEARANCE FORROOFING FELTS

T

H4"

CONCRETE DECK

3"

¾" CLEARANCE FORROOFING FELTS

WOOD DECK

Models ES100, 200, 300 + 18 Gauge galvanized steel + 12" Height, 4" Width + Wood nailer + Flashing cap

Standard Construction

+ Widths: 4", 6", 8" + Aluminum construction + Pressure-treated wood nailer + 14, 16 Gauge galvanized steel

Options

ES100Self Flashing, Surface Mount Straight

ES200Surface Mount, 45° Cant Step

ES300Surface Mount, 45° Cant

+ Equipment supports must be ordered Length × Width × Height

+ ES200: Step height required

Pricing Notes

ES Equipment Supports

Buckley

SMW Local 17

BUCKLEY

Page 39: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

39

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

growing familyLab air exhaust systems for every application.

Vektor®-MH Vektor®-HS

Vektor®-MS High Plume DilutionHigh Plume

High Plume Variable Geometry Nozzle

Vektor®-CD

Vektor®-MD with ERS UnitVektor®-H

Greenheck Vektor® self-enclosed, high-plume and high-plume dilution rooftop laboratory exhaust systems remove fumes and expel them away from roof, neighborhood and building make-up air systems. There are Vektor systems for virtually any need — small high school labs, universities, hospitals and high-volume R&D facilities. Models are available to handle volumes from 24,000 to 120,000 cfm, constant volume and variable volume, or demand-based exhaust high plume dilution, and energy recovery. The new Vektor-MS fills a cost-performance niche, with variable-volume operation (up to 38,500 cfm, 8 in. wg), allowing larger building turndowns for greater energy savings (up to 50% savings). All Vektor system components are manufactured and tested by Greenheck, ensuring the highest quality and reliability.

Learn more from your Greenheck representative or at greenheck.com

Fans & Ventilators | Centrifugal & Vane Axial Fans | Energy Recovery Ventilators | Packaged Ventilation Systems

Make-up Air Units | Kitchen Ventilation Systems | Dampers | Louvers | Lab Exhaust Systems | Coils

715.359.6171greenheck.com

• High-plume dispersal• AMCA certifi cations

for Air, Sound and Air or Induced Flow FanAir and Sound

• Self-contained design

• Safety and comfort inside and outside the facility

• Quiet operation and energy effi ciency

• Easy installation and maintenance

• High schools anduniversities

• Hospitals• Pharmaceutical/Biotech• Research facilities

APPLICATIONS

FEATURES

VEKTOR® SYSTEMS

BENEFITS

©20

18 G

reen

heck

Vektor-HVektor-MS Vektor-MH

Vektor-MDVektor-CD

Vektor-HS

Learn more at AntecControls.com

LABORATORY AND HEALTHCARE AIRFLOW CONTROL SOLUTIONSAntec Controls Healthcare and Laboratory solutions provide precision airflow and environment control for critical spaces. The Antec Controls offering includes industry leading airflow control devices with high turn down capabilities and control systems that can provide energy savings while creating a safe working environment.

Page 40: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

40

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Dimensional Data

Model A B C Roof Opening

G070 17 19C\, 12Z\, 10Z\x × 10Z\x

G080 17 21C\v 14B\, 12Z\x × 12Z\x

G090 17 21C\v 14B\, 12Z\x × 12Z\x

G09517 21C\v 14B\, 12Z\x × 12Z\x

G095-VG

G099-VG 19 24C\, 23C\v 14Z\x × 14Z\x

G103-VG 19 24C\, 23C\v 14Z\x × 14Z\x

G12319 24C\, 23C\v 14Z\x × 14Z\x

G123-VG

G133-VG 19 24C\, 23C\v 14Z\x × 14Z\x

G143-VG 22 28C\, 23C\v 18Z\x × 18Z\x

The Greenheck Model G is a direct drive centrifugal roof exhaust fan. The Greenheck Model G-VG is a roof exhaust fan featuring the VariGreen Brushless DC motor. The VariGreen motor blends technology, controllability and energy-efficiency into a low maintenance package that is changing the way the industry designs, specifies, and operates air movement equipment.

These fans are specifically designed for roof mounted applications exhausting relatively clean air.

+ Aluminum housing + Non-overloading backward inclined wheel + Aluminum curb cap with pre punched mounting holes + Integral reinforced bead for strength + Galvanized birdscreen + Ball bearing motors (sizes 123-163), sleeve bearing

motors (sizes 065-095) + Motor isolated on shock mounts + Corrosion resistant fasteners + NEMA-1 disconnect, mounted and wired + UL/cUL 705 Electrical

Standard Construction

+ Damper Motor Kit, Model MP100 120/24V List Price 214. (120V) 394. (24V)

+ Speed Control Switch, Model 5WSPEED (Model G)List Price 72.

+ Greenheck Single Phase Starter, Model MS-1P (Constant Speed Aplications Only)

List Price 387.

Accessories

A

B

C

13/4 in.

*

Greenheck certifies that the G models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705E40001 - G

Direct Drive Roof Exhaust Fan

G/G-VG Direct Drive Roof Exhaust Fan

Page 41: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

41

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

G/G-VGPerformance Data & Pricing

Performance shown is for installation type A: Free inlet, free outlet. Power rating (BHP) does not include drive losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudless values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.Greenheck Starter Model MS-1P can only be used with constant speed applications only.

Stock Model G centrifugal roof exhaust fans include: birdscreen, disconnect switch, UL/cUL 705 Electrical.

Model HPMaxRPM

Sones@ .25

Max BHP

Static Pressure in Inches of W.G.

FanDamper WD100 Roof Curb0.125 0.25 0.375 0.5 0.625 0.75 1.0 1.25 1.50

G070 Z\c/

1050 2.7 0.01 179

878. 139.8 × 8

277.GPI171300 2.6 0.01 257 171

1550 4.7 0.02 327 274 190

G080 Z\x/

1050 4.2 0.01 249 134

975. 162.10 × 10

277.GPI17

1300 5.5 0.02 348 272 174

1550 7.2 0.04 439 379 314 237

G090 Z\zb

1050 4.2 0.01 420 293

975. 162.10 × 10

277.GPI17

1300 5.5 0.03 565 478 373

1550 7.4 0.05 701 633 557 473

G095 Z\,

1050 4.5 0.03 570 389

975. 162.10 × 10

277.GPI17

1300 6.4 0.06 780 640 493 184

1550 8.8 0.10 969 863 745 623

G095-VG Z\n 1725 11.4 0.13 1098 1013 903 800 688 1,615. 162.10 × 10

277.GPI17

G099-VG Z\v 1725 13.4 0.25 1250 1192 1135 1076 1013 949 806 2,236. 165.12 × 12

293.GPI19

G103-VG Z\v 1725 11.5 0.29 1405 1351 1298 1250 1193 1126 955 2,336. 165.12 × 12

293.GPI19

G123 Z\n 1140 8.4 0.14 1300 1213 1112 993 1,574. 165.12 × 12

293.GPI19

G123-VG Z\x 1725 17.0 0.50 2038 1984 1928 1871 1810 1743 1600 1426 1180 2,543. 165.12 × 12

293.GPI19

G133-VG C\v 1725 16.7 0.60 2393 2338 2281 2220 2159 2089 1935 1746 1474 2,939. 165.12 × 12

293.GPI19

G143-VG C\v 1300 17.4 0.79 2797 2719 2644 2566 2396 2191 1910 1297 3,005. 190.16 × 16

319.GPI22

Direct Drive Roof Exhaust Fan

Page 42: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

42

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Dimensional Data

Model A B C* Roof Opening

GB071

19 24C\, 23C\v 14Z\x × 14Z\x

GB081

GB091

GB101

GB121

GB14122 28C\, 23C\v 18Z\x × 18Z\x

GB161

GB18030 35Z\x 28 20Z\x × 20Z\x

GB200

GB240 34 42C\v 31Z\x 26Z\x × 26Z\x

GB300 40 50 36 32Z\x × 32Z\x

The Greenheck Model GB is a belt driven centrifugal roof exhaust fan. These fans are specifically designed for roof mounted applications exhausting relatively clean air with centrifugal wheels.

+ Aluminum housing + Non-overloading backward inclined wheel + Galvanized birdscreen + Integral reinforcing bead for strength + Double studded isolators for true vibration isolation + Motor out of airstream + Motor pulley is adjustable for system balancing + UL/cUL 705 Electrical + NEMA-1 disconnect, shipped loose

Standard Construction

A

B

C*

13/4 in.

Greenheck certifies that the GB models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705E40001 - GB

GB Belt Driven Roof Exhaust Fan

Belt Driven Roof Exhaust Fan

+ Damper Motor Kit, Model MP100 120/24V List Price 214. (120V) 394. (24V)

+ Greenheck Single Phase Starter, Model MS-1P List Price 387.

Accessories

Page 43: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

43

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

* Price add for mounting in curb model selected.

GBPerformance Data & Pricing

Stock Model GB centrifugal roof exhaust fans include: birdscreen, disconnect switch (not mounted), UL/cUL 705 Electrical.

Model HP RPM-R# TSSones@ 0 in.

Max BHP

Static Pressure in Inches of W.G.

1 Phase 3 PhaseDamper

WD100 Roof Curb0.125 0.25 0.375 0.5 0.625 0.75

GB071 Z\v

930-R2 2724 3.3 0.02 166 124

1,714 -- 165.12 × 12

293.GPI19

1070-R3 3134 4.6 0.03 202 167 130

1285-R4 3764 6.8 0.05 255 228 197 166 127

GB081 Z\v

720-R1 2109 3.0 0.01 272

1,714. -- 165.12 × 12

293.GPI19

930-R2 2724 4.6 0.03 399 323

1140-R4 3339 6.6 0.05 517 460 396 283

1490-R5 4364 10.1 0.12 706 663 621 574 525 452

GB091 Z\v

790-R1 2314 4.2 0.02 471 291

1,714. -- 165.12 × 12

293.GPI19

930-R2 2724 5.6 0.04 598 481

1070-R3 3134 7.3 0.06 718 621 512

1285-R4 3764 9.5 0.11 897 819 736 647 526

1725-R5 5053 13.6 0.26 1250 1192 1135 1076 1013 949

GB101

Z\v

860-R1 2505 4.6 0.04 623 473

1,769. --165.

12 × 12293.GPI19

1000-R1 2913 5.5 0.06 753 654 481

1245-R2 3627 7.5 0.11 978 908 824 715

1555-R3 4530 10.2 0.22 1255 1196 1140 1079 1005 917

Z\c1725-R4 5025 12.2 0.30 1405 1351 1298 1250 1193 1126

1,866. 2,0761800-R5 5243 13.3 0.33 1471 1419 1368 1321 1270 1209

GB121Z\v

860-R1 2941 5.4 0.06 932 796 580

1,909. -- 165.12 × 12

293.GPI19

1000-R3 3420 6.7 0.10 1119 1013 883 694

1265-R3 4326 10.2 0.20 1460 1384 1299 1204 1093 950

Z\c 1475-R4 5045 13.5 0.31 1726 1661 1594 1521 1441 1356 2,006. 2,216.

GB141

Z\v

720-R2 2757 5.8 0.08 1169 938

2,019. --

190.16 × 16

319.GPI22

950-R3 3634 8.1 0.16 1636 1506 1344 1085

1075-R3 4116 10.0 0.24 1882 1771 1647 1490

Z\c 1140-R4 4365 11.0 0.31 2008 1905 1792 1660 1233 2,116. 2,326.

Z\x 1360-R5 5207 14.6 0.48 2433 2347 2259 2166 1943 2,153. 2,366.

C\v 1450-R6 5552 16.2 0.65 2606 2524 2443 2358 2165 2,351. 2,420.

1 1725-R7 6505 20 1.1 3129 3059 2991 2923 2782 2,753. 2,714.

GB161

Z\v

580-R2 2524 5.8 0.08 1417 970

2,286. --

190.16 × 16

319.GPI22

720-R2 3133 7.8 0.15 1893 1632 1243

860-R2 3743 10.5 0.26 2344 2145 1913 1596

Z\c 945-R3 4113 12.6 0.34 2612 2434 2236 2010 2,383. 2,593.

Z\x 1100-R4 4787 15.4 0.48 3095 2943 2787 2615 2468 2,420. 2,633.

C\v 1200-R5 5222 17.0 0.70 3403 3263 3123 2977 2641 2,618. 2,687.

1 1375-R6 5984 21 1.0 3938 3815 3694 3571 3304 3,020. 2,981.

GB180

Z\v 730-R1 3535 7.4 0.21 2668 2469 1882 2,692. --

220.18 × 18

395.GPI30

Z\c 810-R1 3923 8.8 0.29 2997 2832 2375 2,790. 3,001.

Z\x 940-R2 4552 12.7 0.46 3527 3388 3052 2601 2,827. 3,041.

C\v 1055-R4 5109 16.2 0.65 3990 3867 3596 3252 3,026. 3,094.

1 1140-R5 5521 17.9 0.98 4329 4216 3980 3684 3,428. 3,388.

1Z\x 1185-R6 5739 19 1.11 4508 4401 4179 3900 -- 3,444.

Belt Driven Roof Exhaust Fan

Page 44: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

44

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

GBPerformance Data & Pricing

Model HP RPM-R# TSSones@ 0 in.

Max BHP

Static Pressure in Inches of W.G.

1 Phase 3 PhaseDamper

WD100

Roof Curb0.125 0.25 0.375 0.5 0.625 0.75

GB200

Z\c 665-R2 3721 9.6 0.34 3378 3085 2706 2087 2,897. 3,107.

220.18 × 18

395.GPI30

Z\x718-R3 4018 10.8 0.43 3700 3422 3109 2684

2,934. 3,147.770-R3 4309 12.1 0.52 4013 3744 3477 3141

C\v 860-R4 4813 14.1 0.73 4548 4289 4068 3811 3085 3,132. 3,094.

1 965-R6 5400 16.7 1.03 5158 4927 4720 4520 4015 3,534. 3,494.

1Z\x 1090-R6 6099 20 1.49 5870 5682 5473 5301 4925 -- 3,551.

GB240

Z\c 505-R2 3239 7.8 0.32 4242 3761 3060 3,699. 3,910.

241.24 × 24

430.GPI34

Z\x 585-R3 3652 10.3 0.49 5031 4666 4195 3562 2112 3,736. 3,950.

C\v623-R4 3995 11.7 0.60 5400 5069 4660 4131 3428

3,935. 4,003.660-R5 4233 13.1 0.71 5757 5449 5094 4636 4073 3217

1 730-R5 4682 15.8 0.96 6428 6158 5861 5507 5077 4568 4,337. 4,297.

1Z\x 778-R6 4990 17.7 1.16 6886 6632 6363 6058 5700 5266 -- 4,354.

2 910-R7 5837 24 1.86 8135 7916 7700 7467 7215 6933 -- 4,429.

GB300

Z\c 365-R2 2915 9.2 0.33 5222 4340 4,841. 5,049.

-- 517.GPI40

Z\x 420-R2 3354 9.6 0.50 6222 5537 4,878. 5,092.

C\v 475-R3 3793 11.4 0.72 7197 6616 5095 5,077. 5,145.

1 530-R4 4232 13.4 1.00 8150 7640 6456 4195 5,478. 5,438.

1Z\x 600-R5 4791 15.9 1.45 9334 8907 7952 6721 -- 5,495.

2 665-R6 5310 18.8 1.97 10425 10060 9228 8269 -- 5,571.

3 760-R7 6069 23 2.94 12007 11704 10997 10242 -- 6,175.

5 890-R8 7107 28 4.73 14157 13898 13335 12716 -- 6,622.

Motors 3HP and above are NEMA Premium Efficiency MotorsPerformance shown is for installation type A: Free inlet, free outlet. Power rating (BHP) does not include drive losses. Performance ratings include the effects of a birdscreen in the airstream. The sound ratings shown are loudless values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

Stock Model GB centrifugal roof exhaust fans include: birdscreen, disconnect switch (not mounted), UL/cUL 705 Electrical.

Belt Driven Roof Exhaust Fan

Page 45: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

45

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Varigreen Upblast Exhaust

CUE-VG Varigreen Upblast Roof Exhaust Fan with Brushless DC Motor

Model HPMaxRPM

Sones@ .25

Max BHP

Static Pressure in Inches of W.G.

Fan120/60/1

Damper WD100 Roof Curb

Vented CurbKE1000.25 0.375 0.5 0.625 0.75 1.0 1.25

CUE099-VG Z\v 1725 13.4 0.17 1156 1100 1041 981 918 759 2,722. 165.12 × 12

293.GPI19

606.KE10019

CUE101-VG Z\v 1725 12.5 0.17 1373 1315 1255 1195 1129 970 2,803. 165.12 × 12

293.GPI19

606.KE10019

CUE121-VG Z\x 1725 16.7 0.48 1923 1869 1816 1763 1710 1571 1406 2,989. 165.12 × 12

293.GPI19

606.KE10019

CUE141-VG C\v 1550 17.5 0.72 2671 2594 2509 2422 2329 2110 1823 3,568. 190.16 × 16

319.GPI22

727.KE10022

Dimensional Data

Model A B C* Roof Opening

CUE099-VG 19 23M\, 28Z\v 14Z\x × 14Z\x

CUE101-VG19 24M\, 28Z\v 14Z\x × 14Z\x

CUE121-VG

CUE141-VG 22 28M, 29C\v 18Z\x × 18Z\x

EDITS MADE: Turned off the visibility of top of the curb cap to the top of the shroud bead. This Dimension isn’t shown in the dimensional table data I received. In addition, it varies with size; not a consistent number.

A 1¾ inch

C*

B

The Greenheck Model CUE-VG is a roof exhaust fan featuring the VariGreen Brushless DC motor. The VariGreen motor blends technology, controllability and energy-efficiency into a low maintenance package. These fans are specifically designed for roof mounted applications or sidewall applications. Exhaust air is discharged directly upward, away from the roof surface.

Greenheck certifies that the CUE models shown here-in are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705UL/cUL 762MH 11745-CUBE

+ Housing fully welded to curb cap with drain trough

+ Aluminum backward inclined wheel + Corrosion-resistant fasteners + Galvanized birdscreen + Ball bearing motors + Double-studded vibration Isolators + NEMA-1 disconnect, shipped loose + Control potentiometer dial + UL/cUL 762 Grease

Standard Construction Accessories

Performance Data & Pricing

+ Varigreen Remote Speed Control Dial for Indoor Wall Mounting, Model 867008 List Price 678.

+ Greenheck Single Phase Starter, Model MS-1P List Price 387.

Page 46: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

46

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Dimensional Data

Model A B C* D Roof Opening Birdscreen Vented Curb Hinged Curb

Cap Kit2

CUBE101 19 24M\, 28Z\v 17C\, 14Z\x × 14Z\x 93.CUBE101BS

606.KE10019

179.CURBCAPKIT100-200

CUBE141 22 28M, 29C\v 19C\, 18Z\x × 18Z\x 107.CUBE141BS

727.KE10022

CUBE180 30 35C\, 28B\, 21 20Z\x × 20Z\x 142.CUBE180BS

968.KE10030

CUBE200 30 35C\, 28B\, 21 20Z\x × 20Z\x 142.CUBE180BS

968.KE10030

CUBE240 34 42C\v 33M\, 25Z\x 26Z\x × 26Z\x -- 1,108.KE10034

--

The Greenheck Model CUBE is a belt driven centrifugal roof exhaust fan. These fans are specifically designed for roof mounted or sidewall applications. Exhaust air is discharged directly upward, away from the roof surface.

+ Aluminum housing + Non-overloading backward inclined wheel + Aluminum curb cap with pre punched mounting

holes + Motor and drives isolated on shock mounts + Galvanized birdscreen + Ball bearing motors + Adjustable motor pulley + Adjustable motor plate + Fan shaft mounted in ball bearings + Static resistant belts + Corrosion resistant fasteners + NEMA-1 disconnect, shipped loose + UL/cUL 762 Grease

Standard Construction

* May be greater depending on motor.2 Hinged kit required to meet NFPA 96 kitchen exhaust

B

C*D

A

13/4 in.

CUBE Belt Driven Upblast Roof Exhaust Fan

Belt Driven Upblast Exhaust

Vented Curb Hinged Curb Cap Kit

+ Damper Motor Kit, Model MP100 120/24V List Price 214. (120V) 394. (24V)

+ Grease Trap, Model 475538List Price 379.

+ Single Phase Starter, Model MS-1P List Price 387.

+ 3-Phase Starter, Model MSSCList Price 891.

Accessories

Greenheck certifies that the CUBE models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the re-quirements of the AMCA Certified Ratings Program.

UL/cUL 705UL/cUL 762MH 11745-CUBE

Page 47: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

47

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

CUBEPerformance Data & Pricing

Model HP RPM TSSones@ 0 in.

Max BHP

Static Pressure in Inches of W.G.

1 Phase 3 PhaseDamper

WD100

Roof Curb0.125 0.25 0.375 0.5 0.75 1.0

CUBE101Z\v

953-R1 2712 5.5 0.29 717 603

2,448. -- 165.12 × 12

293.GPI19

1252-R2 3563 8.0 0.55 1000 920 834 732

1660-R3 4724 12.7 0.15 1365 1313 1251 1189 1056 861

Z\c 1820-R3 5179 14.3 0.20 1505 1459 1406 1350 1234 1106 2,545. 2,745.

CUBE141

Z\v590-R1 2259 5.0 0.04 851

2,680. --

190.16 × 16

319.GPI22

1105-R2 4231 10.9 0.26 1906 1793 1667 1515 998

Z\c 1210-R3 4633 12.2 0.34 2106 2006 1896 1773 1443 2,777. 2,929.

Z\x 1390-R4 5322 14.9 0.52 2445 2362 2271 2174 1949 1643 2,813. 3,027.

C\v 1595-R5 6107 20 0.79 2826 2757 2683 2602 2430 2225 3,012. 3,080.

CUBE180

Z\v 745-R1 3608 9.2 0.26 2617 2448 1763 3,224. --

220.18 × 18

395.GPI30

Z\c 820-R3 3971 11.2 0.35 2916 2759 2257 3,321. 3,531.

Z\x 940-R4 4552 13.8 0.52 3389 3243 2879 2363 3,357. 3,571.

C\v 1075-R4 5206 16.5 0.78 3919 3786 3554 3141 2652 3,556. 3,624.

1 1185-R5 5739 18.5 1.05 4348 4224 4005 3703 3336 3,958. 3,918.

1Z\x 1360-R6 6586 23 1.58 5026 4913 4710 4532 4232 -- 3,975.

2 1495-R7 7240 28 2.10 5546 5443 5254 5082 4921 -- 4,050.

CUBE200

Z\c 665-R2 3721 9.6 0.35 3422 3096 2699 2073 3,659. 3,870.

220.18 × 18

395.GPI30

Z\x 760-R3 4252 12.3 0.52 3994 3718 3413 3048 3,696. 3,910.

C\v 875-R4 4896 16.4 0.80 4676 4439 4192 3922 3240 3,895. 3,963.

1 960-R5 5371 18.9 1.04 5176 4958 4742 4508 3985 3169 4,297. 4,257.

1Z\x 1100-R6 6155 24 1.57 5992 5798 5610 5421 5006 4529 -- 4,313.

2 1210-R7 6770 24 2.09 6628 6451 6279 6108 5748 5350 -- 4,389.

CUBE240

Z\c 510-R2 3271 8.9 0.35 4243 3717 3134 4,732. 4,943.

241.24 × 24

447.GPI34

½ 585-R3 3752 11.5 0.53 4961 4540 4093 3565 4,769. 4,983.

C\v 670-R4 4297 14.3 0.79 5763 5461 5052 4659 3524 4,968. 5,036.

1 735-R5 4714 16.6 1.04 6370 6133 5764 5409 4618 5,370. 5,330.

1Z\x 845-R6 5419 19.6 1.58 7400 7184 6947 6615 6002 5282 -- 5,386.

2 930-R7 5964 24 2.11 8194 7985 7798 7536 6953 6375 -- 5,462.

Performance shown is for installation type A: Free inlet, free outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream. The sound ratings shown are loudless values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

Stock Model CUBE centrifugal roof exhaust fans include: disconnect switch (not mounted), UL/cUL 762 label and heat baffle.

Replacement PSC Motors for Belt-Driven Fans

Phase

Horsepower

Z\v Z\c Z\x C\v 1 1Z\x 2 3

1 Phase 120V

475..25HP1PH

485..33HP1PH

592..50HP1PH

659..75HP1PH

937.1HP1PH

-- -- --

3 Phase 208/230/460

-- 508..33HP3PH

508..5HP3PH

569..75HP3PH

609.1HP3PH

678.1.5HP3PH

839.2HP3PH

1,279.3HP3PH

Belt Driven Upblast Exhaust

Page 48: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

48

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

+ Brushless DC motor + Dual speed - full speed and continuous low speed + Delay timer + LED Light (SIG-80-110DLED) + Optional ceiling radiation damper (SIG-CRD)

Standard ConstructionSIG80-110DSIG80-110DLED

Ceiling Ventilation Fans

Delta BreezSignature Series Ventilation Fans

+ Brushless DC motor + Single speed - continuous 80 CFM + Ceiling or wall mount + Low profile design - 4" Height

Standard ConstructionSLM-80

SIG80-110D SIG80-110D-LED SLM-80 SIG-CRD

Model SIG80-110D SIG80-110DLED SLM80

List Price 492. 657. 236.

Ceiling Radiation Damper

193. 193. --

Char

acte

risiti

cs (H

VI C

ertif

ied

Data

)

Motor Type DC DC DC

Full Speed (CFM) 80, 110 80, 110 80

Low Speed (CFM) 0, 30, 50, 60, 80 0, 30, 50, 60, 80 --

Delay Timer Yes Yes No

Light Yes Yes No

Energy Star $ $ $

Max Static Pressure in Inches W.G.

0.1 0.25 0.1 0.25 0.1 0.25

CFM 110 110 110 110 80 62

Sones <0.3 0.8 <0.3 0.8 0.6 1.1

Watts 8.2 14.1 9.7 15.5 8.5 10.9

Energy Efficiency (CFMs/Watt)

15.3 8.7 12.7 8.0 9.4 5.6

Duct Diameter 4 or 6 4 or 6 4 or 3

DimensionsL × W × H

10 × 10 × 8 10 × 10 × 8 11 × 11 × 4

Page 49: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

49

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Model FV-05-11VQ1 FV-11-15VQ1 FV-05-11VKS2 FV-05-11VKSL2 FV-20VQ3 FV-30VQ3

Price 444. 579. 606. 885. 665. 697.

Char

acte

risiti

cs (H

VI C

ertif

ied

Data

)

Motor Type DC DC DC DC AC AC

Full Speed (CFM)

50, 80, 110 110, 130, 150 50, 80, 110 50, 80, 110 190 290

Low Speed (CFM)

-- -- 0, 30-100 0, 30-100 -- --

Delay Timer No No Yes Yes No No

Light No No No Yes No No

Energy Star $

Max Static Pressure in Inches W.G.

0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25

CFM 110 111 150 152 110 113 110 114 190 144 290 257

Sones <0.3 0.9 <0.3 0.7 <0.3 0.8 0.4 0.9 0.8 1.4 2.0 -

Watts 10.6 16.4 11.8 20.2 9.8 16.1 11.1 17.6 42 42 64 62

Energy Efficiency

(CFMs/Watt)10.6 6.9 12.9 7.6 11.5 7.2 9.9 6.3 4.5 3.4 4.6 4.1

Duct Diameter

4 or 6 6 4 or 6 4 or 6 6 6

Dimensions L × W × H

10 × 10 × 7 10 × 10 × 7 12 × 14 × 17 12 × 14 × 17 19 × 16 × 12 19 × 16 × 12

FV-05-11VKS2 FV-11-15VQ1 FV-05-11VKSL2 FV-20VQ3

Panasonic Whisper Ceiling/Green Ventilation Fans

Ceiling Ventilation Fans

+ Brushless DC motor + Single speed - adjustable

Standard ConstructionFV-05-11-VQ1FV-11-15VQ1

+ Brushless DC motor + Dual speed - full speed and

continuous low speed + Delay timer + LED Light (FV-05-11VKSL2)

Standard ConstructionFV-05-11VKS2FV-05-11VKSL2

+ AC motor + Single speed

Standard ConstructionFV-20VQ3FV-30VQ3

Page 50: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

50

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Ceiling Exhaust Fans

The Greenheck Model SP ceiling exhaust fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.

SPCeiling Exhaust Fans

Performace Data

ModelEnergy

Star RPM Amps Watts

Sones @ 0 in. Dimensions

Static Pressure in Inches of W.G.

Fan 120/60/10 0.10 0.125 0.250 0.375 0.50

SPA250 $ 1000 0.56 67 2.5

14 × 11M\, × 11Z\v

294 274 271 250 230 201 619.

SPA290 1050 0.72 81 2.5 315 293 287 257 231 207 687.

SPA390 1350 1.34 135 4.5 410 395 391 368 345 325 728.

SPA510 1070 3.30 224 5.018 × 14C\, × 14Z\x

557 512 501 439 392 325 940.

SPA710 1080 4.40 285 6.0 752 714 701 653 588 486 1,177.

SPB70 675 0.16 17 0.813M\, × 11Z\x × 7

89 75 71 54 35 276.

SPB80 $ 900 0.16 17 0.8 94 81 77 62 46 276.

SPB90 $ 700 0.18 21 1.0

13M\, × 14Z\x × 7

104 92 89 72 57 276.

SPB110 950 1.14 80 1.5 133 114 110 97 95 94 308.

SPB150 1050 1.70 128 2.5 160 156 155 154 152 149 368.

SPB200 1100 2.20 172 3.5 197 195 194 191 187 184 413.

SPC50 1680 0.80 46 3.0 7Z\x × 7Z\x × 3B\, 52 49 49 47 44 38 207.

¹ HVI sones at 0 wg Performance shown is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.

SP-A In the top of its class when it

comes to meeting sound

SP-B Compact enough for almost

any application

SP-CDesigned for light commercial

applications

+ Vibration Isolation Kit, Model SPCSVIBKIT List Price 35.

+ Speed Control Switch, Model 5WSPEEDList Price 72.

Accessories

Page 51: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

51

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Ceiling Exhaust Fans

The Greenheck Model CSP inline cabinet exhaust fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward curved wheels.

CSPInline Cabinet Exhaust Fans

Greenheck certifies that the CSP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publica-tion 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 507E33599

Cabinet Fans are also UL listed for sizes 50 through 390 for above bathtub/shower with GFCI branch protected circuit. File No. E33599.

Model RPM AmpsMax

Watts Dimensions

Sones/Static Pressure in Inches of W.G.

Fan120/60/1

Speed Control0 0.10 0.125 0.250 0.375 0.50

CSPA125 1100 0.63 23

12M, × 10B, × 9

CFM 138 126 124 114 91523.

72.5WSPEED

Sones 1.1 1.1 1.1 1.0 1.2

CSPA190 1400 1.10 55CFM 215 202 198 180 159 121

619.Sones 2.0 1.5 2.0 2.0 2.5 2.5

CSPA250 1000 0.79 67

14 × 11M, × 11Z\v

CFM 266 246 241 221 205 187622.

Sones 0.9 1.0 1.0 2.0 2.5 3.0

CSPA290 1050 0.71 102CFM 318 299 292 265 248 229

687.Sones 1.1 1.2 1.3 2.0 2.5 3.5

CSPA390 1350 1.33 161CFM 412 400 397 382 363 339

728.Sones 2.0 2.0 2.0 2.5 3.0 4.0

CSPA410 1000 1.87 132

18 × 14C, × 14Z\x

CFM 447 411 403 364 316 217775.

Sones 1.5 1.5 1.5 2.0 2.0 2.0

CSPA510 1070 3.11 218CFM 545 514 506 464 405 324

940.Sones 2.5 2.0 2.0 2.0 2.0 2.5

CSPA710 1080 4.40 333

14 × 14C, × 14Z\x

CFM 737 698 688 635 567 4751,177.

Sones 2.5 2.5 2.5 2.5 2.0 2.0

CSPA780 1600 3.77 496CFM 813 784 777 742 707 672

1,177.Sones 3.0 3.0 3.0 3.0 3.0 2.0

CSPA1050 1095 6.65 469

23C\v × 11Z\x × 14Z\x

CFM 1182 1110 1093 1013 922 8321,719.

138.10WSPEED

Sones 2.5 2.5 2.5 2.5 2.5 2.5

CSPA1550 1610 8.32 913CFM 1672 1618 1604 1543 1484 1427

1,901.Sones 5.0 4.5 4.5 4.5 4.5 4.0

CSPB110 950 1.14 80

13M, × 11Z\x × 7

CFM 103 100 100 98 97 96331.

72.5WSPEED

Sones 1.5 2.0 2.0 2.0 2.5 2.5

CSPB150 1050 1.70 129CFM 151 150 149 148 144 146

368.Sones 2.0 2.0 2.0 2.0 2.5 2.5

CSPB200 1050 2.20 173CFM 186 184 184 182 181 179

413.Sones 3.0 3.0 3.0 3.0 3.5 3.5

Inlet and outlet connection widths are 1 inch - Mounting bracket width is 1½ inchPerformance shown is for Model CSP inline for installation type D: Insulated Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) from the test inlet duct in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction.

CSP-APremium Inline Fan

CSP-B Deluxe Inline Fan

+ Vibration Isolation Kit, Model SPCSVIBKIT List Price 35.

Accessories

Performace Data

Page 52: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

52

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

+ Available in two models + Use with shaded pole and open

permanent split capacitor motors + 115 volt single phase only.

Fan Accessories

+ Aluminum construction, aluminum finish + For outside wall applications + Built in birdscreen and damper

ModelFor Use With Models/Sizes A B C D E

List Price

WC4* C50 6Z\x 6 4 4 5 75.

WC6B50-B200, A50-

A1908 8 6 4Z\, 5 92.

WC8 A200-A510 11 11 8 5Z\, 3Z\x 142.

* Model WC-4 is not available with birdscreen.

B

ECA

DE

+ Steel construction with black enamel finish + For outside wall applications + Built in birdscreen and damper

Model

For Use With

Models/Sizes A B C D E F G

ListPrice

WC 10 x 3 50-290 5Z\x 12C\v 3Z\x 10Z\v 11Z\, 4Z\v 5 85.

WC 8 x 8 200-510 10Z\v 10Z\v 8Z\v 8Z\v 8Z\v 6C\v 5 134.

WC 18 x 8 700-1550 10Z\v 20Z\v 8Z\v 18Z\v 18Z\v 6C\v 5 164.

D

A

G

C

B

E

F

WCHooded Wall Cap, Round Connection

WCHooded Wall Cap, Rectangular and Square Connection

GTDTime Delay Switch

Fan Speed Control Switch

Model Max Amps List Price

5WSPEED 5 72.

10WSPEED 10 138.

867008Remote Dial for Varigreen Motors

+ A potentiometer can be plugged into the 9-pin connector of the motor.

+ To be used to control fan speed from a varigreen motor.

+ Applicable with Model G and Cue-VG. List Price 91.

+ Automaticaly turns off equiptment + Saves energy + Assembly consists of a single pole,

single throw switch, a timer, and cover plate

List Price 284.

+ Manually adjusts fans speed + Mounts to wall + Includes transformer, remote dial,

and mounting bracket

List Price 678.

385806Potentiometer for Varigreen Motors

380044Reverse Acting Thermostat

+ Contacts close on temperature rise. + Adjustable range 30° to 110° F

List Price 239.

Page 53: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

53

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Fan Accessories

+ Designed for installation under roof eaves + Painted steel louvered grille + Built in damper + For SP/CSP sizes 50-290

List Price 133.

+ Available for suspended installations. + Hardware included to mount unit + 1/4-20 threaded rod to be provided by others. + Pre-punched mounting holes for ease of installation.

List Price 35. AB

10-32 hanging support rod

by others

ModelFor Use With Models/Sizes A B C D Dia.

ListPrice

Roof Curb

RFC7 50-390 18 12 10 6C\, 7 305. --

RCC7 50-390 15 12 10 6C\, 7 320. 267.GPI15/12

+ Steel construction with black enamel finish + Integral flashing flange + Built in birdscreen and damper

ModelFor Use With Models/Sizes A B Throat

ListPrice

RJ4 C50, B50-B80 11 9Z\v 4" Dia 97.

RJ6 x 9 B90-B200, A50-A390 18C\v 14Z\v 6 × 9 115.

RJ10 x 10 A410-A1550 18Z\x 27Z\x 10 ×10 259.

A

B

CD

E

RJPitched Roof Cap

EL10X3Elbow Discharge with Grille

RFC7/RCC7Flashing Flange/ Flat Roof Cap (Curb Cap)

SPCSPVIBKITHanging Vibration Isolators

Motor StartersBuilding Automation Starters for 1Ø and 3Ø Applcations

MS-1PSingle Phase

Starter

MSSC-1-9/J-40Economical

Starter

MSAC-1-9/J-40Advanced

Starter

List Price 387. 891. 1,015.

Disconnect Yes No No

Adjustable Overload 1-16A 1-40A 1-40A

Enclosure NEMA1 NEMA1 NEMA1

Inputs 1 2 6

Outputs 1 1 3

Max

HP

1Ø120V 1 -- --

230V 1 1 1

280V -- 2 2

230V -- 2 2

460V -- 5 5

111⁄8

31⁄210

91⁄4

11 1⁄251 ⁄8

RCC7RFC7

Page 54: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

54

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

BSQInline Centrifugal Fan Belt Drive

+ Galvanized steel housing + Non-overloading backward inclined aluminum wheel + Side access panels + Inlet and outlet duct connection flanges + Ball bearing motors + Adjustable motor pulley and motor plate + Fan shaft mounted in ball bearing pillow blocks + Static resistant belts + Corrosion resistant fasteners + UL/cUL 705 Electrical + Motor cover + Disconnect switch (shipped loose)

Standard Construction Accessories

The Greenheck Model BSQ is a belt driven centrifugal inline fan. These fans are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where space is a prime consideration.

A

B D

C

G F

H

E

Model

Dimensions

A B/C D E F G H*

BSQ70

11M\, 15 21 1 14 15Z\x 12Z\xBSQ80

BSQ90

BSQ100

BSQ120 15M\, 19 21 1 16 17M\, 12Z\x

BSQ140 19M\, 23 22 1 16 17M\, 12Z\x

BSQ180 23M\, 28 28 1Z\x 18 24C, 13C\v

BSQ240 34M\, 39 34 1Z\x 22 32M\, 19

Dimensional Data

+ Hanging Isolators, Models HVI 70-140/160-240 List Price 184. (70-140) 264. (160-240)

+ Single Phase Starter, Model MS-1P List Price 387.

+ 3-Phase Starter, Model MSSCList Price 891.

Inline Fans

Greenheck certifies that the SQ, BSQ models shown herein are li-censed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publica-tion 211 and AMCA Publication 311 and comply with the require-ments of the AMCA Certified Ratings Program.

UL/cUL 705E40001 - SQ/BSQ

Page 55: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

55

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

*Not Stocked. Available from factory

Model HP RPM-R# TSSONES@ .125 in.

MAX BHP

Static Pressure in Inches of W.G.

1 Phase 3 PhaseBDD

Damper0.125 0.25 0.5 0.75 1.0 1.25

BSQ70 Z\v1050-R2 3074 8.0 0.04 184 129

2,758. --

106.12 × 12

1445-R2 4231 12.8 0.103 284 249 169

BSQ80 Z\v1520-R2 4451 13.9 0.15 585 542 442 301

2,810. --1833-R2 5367 17.2 0.25 720 687 613 524 424

BSQ90 Z\v1211-R2 3546 9.8 0.10 655 574 333

2,915. --1694-R2 4960 16.0 0.25 965 914 798 654 437

BSQ100 Z\v1330-R2 3894 11.3 0.14 1024 953 770

2,827 -- 123.14 × 141609-R2 4711 15.4 0.25 1265 1207 1088 917

BSQ120

Z\v1000-R2 3436 7.7 0.10 1026

2,995. --

138.16 ×16

1367-R2 4697 10.9 0.24 1471 1226 1020

Z\c1437-R3 4938 11.7 0.28 1555 1323 1145

3,092. --1506-R3 5175 12.5 0.32 1636 1418 1252 1027

Z\x1615-R4 5549 13.8 0.39 1764 1562 1418 1245

3,129. 3,343.1724-R4 5924 15.2 0.48 1892 1703 1571 1423 1241

C\v 1974-R5 6783 19.0 0.71 2183 2020 1908 1791 1663 3,327. 3,396.

12073-R6 7123 21.0 0.82 2298 2142 2037 1928 1813

3,729. 3,690.2172-R6 7463 23.0 0.94 2413 2264 2164 2062 1953

BSQ140

Z\v800-R1 3050 6.3 0.10 1362 1185

3,077. --

182.20 × 20

1076-R1 4102 10.7 0.24 1927 1810 1538

Z\c 1185-R2 3517 12.1 0.32 2142 2039 1807 1463 3,174. 3,384.

Z\x1271-R3 4845 13.3 0.40 2311 2217 2006 1741 1199

3,211. 3,424.1356-R3 5169 14.2 0.48 2476 2392 2197 1979 1636

C\v 1553-R4 5920 16.2 0.71 2858 2787 2626 2449 2253 3,409. 3,478.

11631-R5 6217 17.1 0.82 3008 2941 2790 2625 2446 3,811. 3,771.

1709-R5 6515 18.2 0.95 3159 3094 2953 2798 2635-- 3,828.

1Z\x 1956-R6 7456 24 1.41 3633 3576 3461 3330 3193

BSQ180

Z\c700-R1 3390 10.0 0.23 2649 2387

3,768. 5,101.

230.24 × 24

791-R1 3831 10.6 0.32 3051 2845 2217

Z\x 905-R2 4383 12.2 0.48 3546 3366 2928 2175 3,805. 4,018.

C\v 1037-R3 5022 14.5 0.71 4109 3955 3616 3179 2432 4,004. 4,072.

1 1141-R4 5526 16.5 0.94 4549 4412 4127 3760 3290 2523 4,406. 4,365

1Z\x 1306-R5 6325 20.0 1.40 5242 5128 4878 4610 4281 3884 4,422.

2 1437-R6 6959 23.0 1.86 5790 5686 5463 5236 4964 4662 4,497.

3 1645-R7 7967 29.0 2.78 6656 6566 6377 6179 5981 5744 5,101.

BSQ240

1 717-R3 4599 16.2 0.93 6816 6498 5782 4884 -- 6,003.

684.*35 × 35

2 903-R5 5792 22.0 1.83 8720 8488 7960 7384 6756 5889 -- 6,135.

3 1034-R4 6632 28.0 2.73 10048 9845 9409 8936 8421 7881 -- 6,744.

5 1225-R5 7857 41.0 4.51 11973 11802 11460 11070 10671 10245 -- 7,064.

BSQPerformance Data & Pricing

Inline Fans

Stock Model BSQ centrifugal inline fans include: disconnect switch, CSA and UL 705.

Page 56: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

56

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Inline Fans

Model

Dimensions

A B C

SQ80-VG

16 15 11M\,SQ90

SQ90-VG

SQ95

SQ100-VG 21 17 13M\,

SQ120-VG 21 19 15M\,

SQ140-VG 22 23 19M\,

+ Galvanized steel housing + Non-overloading backward inclined aluminum wheel + Side access panels + Inlet and outlet duct connection flanges + Ball bearing motors + Corrosion resistant fasteners + UL/cUL 705 Electrical + Disconnect switch

Standard Construction Accessories

The Greenheck Model SQ is a direct drive centrifugal inline fan. The Greenheck Model SQ-VG is an centrifugal inline featuring the VariGreen Brushless DC motor. These fans are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where space is a prime consideration.

A 1 in.1 in.

C sq.

B sq.

C sq.

B sq.

SQ/SQ-VGInline Centrifugal Fan Direct Drive

Performance Data & Pricing

Model HPMax RPM

SONES@ 0 in.

MAX BHP

Static Pressure in Inches of W.G.Fan

115/60/1Damper

BDD0 0.125 0.25 0.375 0.5 0.625 0.75 1.0

SQ80-VG Z\n 1725 8.4 0.05 503 451 404 354 294 2,506. 106.12 × 12

SQ90-VG Z\n 1725 8.8 0.07 821 748 669 579 481 366 2,506. 106.12 × 12

SQ90

Z\b/ 1050 4.0 0.016 500 370 188

1,478. 106.12 × 12

Z\xb 1300 5.4 0.03 619 519 398 245

Z\z/ 1550 7.6 0.051 738 655 565 457 334

SQ95

Z\c/ 1050 4.9 0.028 623 475 275

1,478. 106.12 × 12

Z\zb 1300 7.6 0.053 771 660 523 352

Z\, 1550 9.6 0.09 920 830 720 604 462 276

SQ100-VG Z\v 1725 13.2 0.22 1455 1403 1350 1292 1227 1156 1078 831 3,014. 123.14 ×14

SQ120-VG Z\x 1725 14.7 0.41 1948 1884 1819 1754 1692 1629 1563 1417 3,681. 138.16 ×16

SQ140-VG C\v 1550 16.7 0.67 2950 2790 2730 2614 2524 2429 2188 4,113. 182.20 × 20

Performance certified is for installation type B, Free inlet, Duct outlet. Performance ratings do not include the effects of appurtenances in the airstream. The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for: Installation Type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

Stock Model SQ centrifugal inline fans include: disconnect switch, CSA and UL 705. Sizes 100+ include a motor cover.VG Models also include speed control dial on motor.

+ Hanging Isolators, Models HVI 70-140 List Price 184.

+ Single Phase Starter, Model MS-1P List Price 387.

+ Speed Control Switch, Model 5WSPEED (SQ only)List Price 72.

+ Varigreen Remote Speed Control Dial for Indoor Wall Mounting, Model 867008 List Price 678.

Page 57: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

57

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Inline Fans

Dimensional Data

Model A C D

FG4XL 4 9C\v 6Bzn

FG5XL 5 9C\v 6

FG6XL 6 13Z, 7

FG8XL 8 13Z\v 6

FG10XL 10 13Z\v 4ZC\zn

FG12XL 12 16 6ZZ\zn

Duct connections are Z\," smaller than duct size.

The Fantech Model FG series is a centrifugal inline fan. These fans are ideal for various commercial code and residential applications. Home uses include range hood exhaust, duct boosting and bathroom exhaust. Office applications include intake, exhaust, filtration, return or makeup air systems that require mounting versatility, high efficiency, low sound levels, and ease of service.

+ Airtight galvanized steel housing + Powered by external rotor motorized impeller + Permanently lubricated sealed ball bearings + 100% speed controllable + Automatic reset thermal overload protection + Prewired electrical box

Standard Construction

Fantech, Inc. Certifies that the FX Series shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and proce-dures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certi-fied Ratings Program.

Performance Data & Pricing

Model RPMMax

WattsMax

Amps

Static Pressure in Inches of W.G.

Fan Damper

RSKClamp

QS*0 .2 .4 .6 .8 1.0 1.5

FG4XL 2000 71 0.66 170 150 134 119 103 86 40 578. 48. 126.

FG5XL 2700 73 0.68 220 190 160 135 112 91 41 592. 58. 128.

FG6XL 2900 153 1.48 483 450 409 369 329 289 201 812. 61. 140.

FG8XL 2950 142 1.45 502 470 428 388 351 313 218 976. 88. 152.

FG10XL 3100 196 1.96 589 560 531 503 472 441 355 1,114. 106. 166.

FG12XL 2900 301 3.01 940 880 819 746 670 596 425 1,499. 151. 188.

* Clamp Model QS is sold in pairs for use with this fan (quantity 2).Performance shown is for installation type D - Ducted inlet, Ducted outlet. Speed (RPM) is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the airstream.

Accessories

FGInline Centrifugal Fan

+ Speed Control Switch, Model 5WSPEED List Price 72.

+ Dryer Booster Pressure Switch, Model DB10 List Price 275.

Page 58: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

58

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Sidewall Propeller Fans

Dimensional Data

Model A B* C* D E

SE1-8 13 7 5 1 8C\,

SE1-10 15 8C\v 5 1 10C\,

SE1-12 18 10C\v 8Z\v 1 12C\,

* Varies with motor selection.

+ Heavy gauge, galvanized steel fan panel with pre-punched mounting holes

+ Resilient motor mounts isolate motor vibrations + Corrosion resistant fasteners + Thermal overload protection with all motors + Riveted aluminum blades + Heavy gauge welded zinc plated wire drive

frame + UL/cUL 705 Electrical

Standard Construction Features

+ Single Phase Starter, Model MS-1P List Price 387.

+ Speed Control Switch, Model 5WSPEED List Price 72.

The Greenheck Model SE-1 is a direct drive sidewall propeller fan. This model fan is used to handle exhaust requirements for smaller size applications and lower static pressures.

B*C* D

E

AirflowExhaust

A Sq.

Accessories

Greenheck certifies that the S models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Pub-lication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705E40001-S

SE-1Sidewall Propeller Exhaust Fan, Direct Drive

Performance Data & Pricing

Performance shown is for Model S1 exhaust for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances in the airstream. Speed (RPM) is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 feet (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type A: free inlet sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only.* Greenheck Starter Model MS-1P can only be used with constant speed applications only.

Stock Model SE-1 sidewall propeller exhaust fans include aluminum propeller, heavy gauge wire motor support, UL 705 and CSA labels.

Model RPMSones @ 0

CFM # of Blades Prop Pitch

Static Pressure in Inches of W.G.Fan

115/60/1Damper

WD3200 0.1 0.125 0.25 0.375

SE1-8

1050 1.5 4 40 311 127 101

749. 215.10 × 10

1350 3.5 4 40 400 257 189

1550 4.9 4 40 459 351 308 167

SE1-10

1050 3.2 4 40 626 361

773. 215.12 × 12

1350 4.9 4 40 805 656 616

1550 5.9 4 40 924 801 763

SE1-12

1050 4.3 4 32 982 745 678

854. 255.14 × 14

1350 6.0 4 32 1262 1098 1038 798

1550 7.5 4 32 1449 1309 1271 1042 861

Page 59: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

VISIT WWW.BIGASSFANS.COM OR WWW.BUCKLEYONLINE.COM FOR MORE INFORMATION.

FOR ENERGY-EFFICIENT COMFORT, THERE’S ONLY ONE NAME YOU NEED TO KNOW

At Big Ass Fans, we don’t just make the best-selling big fans in the world, we’re also the world authority on large-scale air movement. Most people have seen our products, but not everyone realizes everything they do. You can count on Big Ass Fans to:

Create cool comfort in summer, where air-conditioning isn’t an option

Circulate heated air in winter, saving up to 30% on heating bills

Work with A/C to lower summer cooling costs

Improve indoor environmental quality year-round

And Big Ass Fans are backed by the best warranties in the industry and the best customer service you’ll find anywhere.

Big Ass Fans: Because every other fan is just a substitute.

Page 60: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

60

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Gravity Hoods

Dimensional Data

Model A B C D Diameter Throat Area (Ft²)

GRS8 19 20Z\x 7Z\v 1Z\x 8Z\v 0.37

GRS10 19 20Z\x 7C\v 2 10Z\v 0.57

GRS12 22 29 10 3Z\x 12Z\v 0.82

GRS15 22 29 10 3Z\x 14Z\v 1.12

GRS16 26 29 11 4Z\v 16Z\v 1.45

GRS18 30 35Z\x 9C\v 1C\v 20Z\v 1.83

GRS20 30 35Z\x 11Z\v 3C\v 20Z\v 2.25

GRS24 34 35Z\v 11 4 24Z\x 3.24

The Greenheck Model GRS is designed for intake or relief applications with either natural gravity or positive pressure systems. The GRS appearance blends with other Greenheck products with its low silhouette, avoids the problem of detracting from architectural aesthetics. Exceptional design and construction features make this unit a rugged, efficient and economical air inlet or outlet.

+ Aluminum housing + Aluminum curb cap with pre-punched mounting holes

Standard Construction + Damper Motor Kit, Model MP100 120/24V

List Price 214. (120V) 394. (24V)

Accessories

Stock Model GRS spun aluminum gravity ventilators include birdscreen.

Model

Total Pressure Drop (in. wg) Volume (CFM)

GRS Roof CurbDamper

WD1000.04 0.06 0.08 0.1 0.15 0.2 0.25

GRS8RELIEF 231 282 326 365 446 516 576

385. 293.GPI19

139.8 × 8INTAKE 178 218 252 282 345 398 445

GRS10RELIEF 331 406 468 524 641 741 828

424. 293.GPI19

162.10 × 10INTAKE 279 342 395 442 541 624 698

GRS12RELIEF 468 573 662 740 907 1047 1171

446. 319.GPI22

165.12 × 12INTAKE 400 490 566 633 775 895 1001

GRS15RELIEF 663 811 937 1048 1283 1481 1656

609. 319.GPI22

190.16 × 16INTAKE 553 677 782 874 1071 1237 1383

GRS16RELIEF 870 1065 1230 1375 1685 1945 2175

632. 333.GPI26

190.16 × 16INTAKE 742 908 1049 1173 1436 1658 1854

GRS18RELIEF 1060 1298 1499 1676 2052 2370 2649

761. 395.GPI30

220.18 × 18INTAKE 901 1104 1274 1425 1745 2015 2253

GRS20RELIEF 1284 1572 1815 2029 2486 2870 3209

783. 395.GPI30

220.18 × 18INTAKE 1096 1343 1550 1733 2123 2452 2741

GRS24RELIEF 1879 2301 2657 2971 3638 4201 4697

1,160. 447.GPI34

241.24 × 24INTAKE 1542 1888 2180 2438 2985 3447 3854

B

CD

Dia.A

1 in.

B

C

D

Dia.A

3/4 1 in.3/4

GRS Spun Aluminum Gravity Ventilators

Performance Data & Pricing

Page 61: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

61

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

FJC Commerical Fume Exhaust Fan

FJC Belt-driven, arrangement 10 unit available in either bolted or welded construction. The unit has a compact footprint with motor and drives located under a common weather hood.

Model FJC-200Galvanized steel and bolted frame construction allows for use in commercial exhausts.

Model FJC-300A corrosion resistant coating allows for use with corrosive exhausts.

FJIIndustrial Fume Exhaust Fan

The FJI is available in belt or direct drive for AMCA class 0, l or ll. Options are available for spark resistance, higher temperature or corrosive exhausts.

FJC and FJIFumeJet Pre-Engineered Fume Exhaust System

Construction FJC - Commercial Fume Exhaust Fan FJI - Industrial Fume Exhaust Fan

Drive Type Belt Drive - Sizes 6-15 Belt or Direct Drive - Sizes 7-24

Material Galvanized (FJC-200), Coated Steel (FJC-300) Coated Steel

Class None Class Offering 0, I, II

Spark Resistance AMCA Spark B or C Spark Resistance (Optional on FJC-300) AMCA Spark B or C Spark Resistance (Optional)

No Guy WiresFactory Tested to Withstand 92 mph without the need of guy wires

Factory Tested to Withstand 92 mph without the need of guy wires

Performance Range Up to 5,000 CFM and 5" wg Up to 15,000 CFM and 8" wg

Max Temperature 400° F Continuous 500° F Continuous

Vibration Testing No Factory Vibration Tested

AMCA AMCA Air (Sizes 6-8) AMCA Sound and Air Perforance

UL UL/cUL Listed 705 UL/cUL Listed 705

FJC-200 FJC-300

Fume Exhaust Systems

Available on a 5-Day Quick Build from Greenheck

Eliminate Inefficient, Complicated and Unsafe Field Built-Up Installations

FJI-15-BD_FJC-215_FJI-DD-C...

Fume-Exhaust_FJC-215-FJI-C...

Fume-Exhaust_FJI-215-FJI-315...

Fume-Exhaust_FJI-FJC_Cover.tif

Fume-Exhaust_FJC-215-315.tif

Fume-Exhaust_FJC215-FJI-Dir...

Fume-Exhaust_FJI-BD-FJI-DD-...

Fume-Exhaust_USF-FE-210-31...

Fume-Exhaust_FJC-215-FJC-3...

Fume-Exhaust_FJI-15_Belt-Driv...

Fume-Exhaust_FJI-DB-FJI-DD-...

Fume-Exhaust_USF-FE-210-31...

FJI

Page 62: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

62

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

ORDER ACCEPTANCE AND DELIVERY All orders for stock prod-ucts or factory shipments are subject to acceptance by Manage-ment. Cancellation of orders after customer release is subject to cancellation charges if special from factory or from Buckley manu-facturing. All manufacturers Quick Ship orders cannot be cancelled once the order is put through the factory. Title and risk of loss pass to the Buyer upon delivery of the Product to the carrier.

Delivery dates given are our best estimate and are not guaranteed. Further, Buckley Associates, Inc. (“Buckley”) cannot be held responsible for any customer liability arising from delays or failures in manufacturing or shipping, for any reason whatever, within or beyond our control.

CUSTOMER ORDER PROCEDURE + Phone orders will be accepted only on the basis of the buyer

assuming full responsibility arising from delays or failures in manufacturing or shipping, for any reason whatever, within or beyond our control.

+ In order to give you accuracy of written orders and also the speed of a phone call, we have a fax machine for the purpose of aiding our customers.

+ On orders totaling $5000.00 or over, we require a Buckley job information sheet filled out before the order will be processed.

+ Some orders may be billed by our manufacturers at the discretion of Buckley Associates, Inc. A written purchase order must be issued c/o Buckley Associates, Inc. to our manufacturer.

+ A $25.00 charge will be assessed to any order shipped out by a common carrier that will require notification prior to delivery.

TERMS OF SALE

PRICES AND SPECIAL QUOTATIONS All prices, unless otherwise specified, are F.O.B. our warehouse or factory. Prices do not include Federal, state or local taxes, which may be imposed on the sale of our product.

NEW QUOTATIONS Will remain in effect for sixty (60) days only, unless otherwise agreed to in writing. All prices are subject to change without notice.

TERMS OF PAYMENT

STANDARD TERMS OF PAYMENT are Net thirty (30) days from date of invoice to qualified customers with open accounts. All invoices, even if disputed, are due and payable on the above terms. Disputed invoice amounts, if legitimate, will be credited accordingly. Accounts with balances over forty-five (45) days are subject to credit hold.

Payment terms are net thirty (30) days from date of invoice on approved credit. In the event an account is placed for collection, purchaser shall be responsible for all reasonable attorneys’ fees and costs incurred by Buckley in securing payment. Invoices unpaid after thirty days shall accrue interest at the rate of 1.5% per month from the date of the invoice.

All sales, use, excise, transportation, privilege, occupational, consumption, storage or other taxes which may be levied by any taxing authority as a result of this transaction shall be paid by the purchaser.

Buckley reserves the right to discontinue absolutely any further sales directly to buyers when any of the terms contained herein are not adhered to.

Buckley requires a one-hundred (100%) percent deposit on special order items (Buckley manufactured or factory orders) when you do not have an open account. Buckley hereby reserves and Buyer hereby grants a purchase-money security interest in each and any and all materials and equipment and a security interest in any and all accessories, proceeds, insurance proceeds therefrom to secure payment of any unpaid purchase price and all other obligations of Buyer to Buckley hereunder and/or hereafter incurred. Buyer agrees to sign upon request any and all further documents, agreements, instruments and statements, if necessary, to protect and/or perfect Buckley’s security interest and Buyer further authorizes Buckley to file Uniform Commercial Code financing statements in the jurisdiction

where such materials and equipment are located. We also accept Visa, Master Card, Discover and American Express. Credit card payments must be used at time of sale and cannot be used to pay down an existing balance. On checks that are insufficient, the issuer will be responsible for bank charges that do incur.

ADDITIONAL ITEMS If Buckley subsequently becomes aware of damaging or unfavorable credit information, it reserves the right at its absolute and sole discretion to suspend credit until it becomes satisfied that the basis for an outgoing credit relationship is sound. It is also understood and agreed that the legal obligation of the above individual(s) or company is for the full amount of actual credit extended by Buckley, and shall not be limited by or “expected” or “requested” credit requirements, “initial line of credit,” or subsequent “credit limits.”

Buyer represents to Buckley Associates that purchases made pursuant to this Agreement shall be for commercial purposes only and not for personal, family or household purposes.

Buyer agrees that payments against any account balance which are not clearly designated to a particular invoice will automatically be applied to the oldest outstanding invoices and/or to outstanding service charges.

Buyer understands and agrees that Buckley Associates will not accept customer “back charges” under any circumstances. In the event of a serious product or service problem or failure, Buckley Associates must be advised immediately so that it can utilize its best efforts to correct the situation and minimize damages.

EXPORT CONTROL Buyer certifies that it will be the recipient of the Products to be delivered by Seller. Buyer understands that the associated hardware, software, and/or technical data (“products”) listed on their Purchase Order includes items that are governed by the U.S. Export Administration Regulations(“EAR”), by the U.S. Foreign Assets Control Regulations (“OFAC”) and the International Traffic in Arms Regulations (“ITAR”). The Buyer understands that its sale or distribution of said products may constitute exports or re-exports, and as such, must be in accordance with the requirements administered by Bureau of Industry and Security, Department of Treasury, and Department of State. It is understood that the country of ultimate destination, commodity classification, end-user, or end-use for any said products, could affect the applicable license requirements and exportability. The Buyer agrees to consult various resources, such as the EAR, ITAR, and OFAC, by the U.S. Department of Commerce’s Bureau of Industry and Security’s (“BIS”) Export Counseling Division, and other appropriate Government Sources to ensure that the sales and distribution of said products, is processed in accordance with all applicable laws. The Seller will not transfer any export-controlled products to a “non-U.S. Person” without the proper authority of the United States Government, and the buyer’s written approval.

FORCE MAJEURE Buckley is not liable for failure to fulfill its obligations for any accepted Order or for delays in delivery due to causes beyond Seller’s reasonable control including, but not limited to, acts of God, natural or artificial disaster, riot, war, strike, delay by carrier, shortage of Product, act or omissions of other parties, acts or omissions of civil or military authority, Government priorities, changes in law, material shortages, fire, strikes, floods, epidemics, quarantine restrictions, acts of terrorism, delays in transportation or inability to obtain labor, materials or Products through its regular sources, which shall be considered as an event of force majeure excusing Seller from performance and barring remedies for no performance. In an event of force majeure condition, the Seller’s time for performance shall be extended for a period equal to the time lost as a consequence of the force majeure condition without subjecting Seller to any liability or penalty. Seller may, at its option, cancel the remaining performance, without any liability or penalty, by giving notice of such cancellation to the Buyer.

CONNECTICUT CUSTOMERS Buyer further acknowledges that this agreement constitutes commercial transaction pursuant to Connecticut General Statutes section 52-278a et seq. and does hereby waive any and all rights to notice of hearing and/or a hearing required for Prejudgment Remedy by Connecticut General Statutes section 52-278a et seq., in the event that litigation is instituted for

Terms & Conditions of Sale

Page 63: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

63

Buckley Associates, Inc. buckleyonline.com | (800) BUCKLEY

Terms & Conditions of Salethe collection of any account debt that may be incurred by the Buyer. Accordingly, Buckley Associates may avail itself of any and all prejudgment remedies without notice of hearing and/or hearing including, but not limited to, garnishment and attachment. The Buyer hereby waives all rights to a trial by jury.

Buyer hereby waives all rights to notice and hearing provided for under Chapter 903-A of the Connecticut General Statutes.

LIMITATION OF LIABILITY EXCEPT AS EXPRESSLY PROVIDED HEREIN, BUCKLEY EXPRESSLY DISCLAIMS ANY REPRESENTATION OR WARRANTY,EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE. SPECIFICALLY, EXCEPT AS EXPRESSLY PROVIDED HEREIN,BUCKLEY MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, WITH RESPECT TO ANY MATERIALS OREQUIPMENT INCLUDING WARRANTIES OR MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE, ORWARRANTIES ARISING FROM COURSE OF PERFORMANCE, COURSE OF DEALING, OR USAGE OF TRADE. IN THE EVENT OFANY DEFECT IN MATERIALS, EQUIPMENT OR WORKMANSHIP, BUCKLEY SHALL ONLY BE OBLIGATED EITHER TO REPAIR OR REPLACE, AT BUCKLEY’S OPTION, SAID GOODS, MATERIALS OR EQUIPMENT AND THE AFORESAID OBLIGATION TO REPAIR OR REPLACE SAID GOODS, MATERIALS OR EQUIPMENT SHALL BE BUYER’S EXCLUSIVE REMEDY. BUCKLEYSHALL NOT, IN ANY MANNER WHATSOEVER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES,INCLUDING LOSS OF PROFITS OR EXPENSES, OR FOR BREACH OR WARRANTY OR NEGLIGENCE ACTIONS.NOTWITHSTANDING ANY PROVISION CONTAINED HEREIN TO THE CONTRARY, BUCKLEY’S TOTAL FINANCIAL LIABILITYTO CUSTOMERS SHALL NOT EXCEED THE PURCHASE PRICE APPEARING UPON THE INVOICE.

General: (a) The laws of the Commonwealth of Massachusetts will exclusively govern any dispute between Seller and Buyer, (b) Buyer may not assign this Agreement without the prior written consent of Buckley. Buckley or its affiliates may perform the obligations under this Agreement. This Agreement is binding on successor and assigns, (c) Products, including software or other intellectual property, are subject to any applicable rights of third parties, such as patents, copyrights and/or user licenses.

IMDEMNIFICATION

Buyer shall be responsible at all times for the proper use, operation and maintenance of any materials and equipment ordered hereunder, and for remaining up to date and compliant with any and all governmental or industry standards, as may be amended or in effect from time to time. Buyer agrees to indemnify and hold Buckley harmless against any and all claims, demands, actions, causes of action, damages, personal injuries, setoffs, liens, attachments, debts, expenses, judgments, or other liabilities of whatever kind or nature, including attorneys’ fees and costs arising in whole or in part out of or resulting in whole or in part from the modification, misuse, or improper operation of any materials and equipment ordered hereunder by Buyer or its officers, directors, employees, independent contractors, agents, affiliates, subsidiaries, parent company, successors and assigns, and/or Buyer’s failure properly to maintain said materials and equipment or to keep said material and equipment in compliance with governmental and industry safety standards.

Buyer shall remain responsible for complying with any law, statute or ordinance governing the use and operation of said materials and equipment and Buyer is responsible for maintaining the same in the manner specified in maintenance materials, instructions and specifications provided by the manufacturer. Buyer agrees to indemnify and hold Buckley harmless against any and all Claims, including reasonable attorneys’ fees and costs to the extent such claims result from Buyer’s modification of said materials and equipment, Buyer’s failure to comply with any law, statute, or ordinance related to the use and operation of said materials and equipment or Buyer’s failure to maintain said materials and equipment in a manner consistent maintenance materials, instructions and specifications provided by the manufacturer. Buyer agrees to indemnify and hold harmless Buckley, its employees,

agents, successors, officers, and assigns, from and against any suits, losses, claims, demands, liabilities, costs and expenses (including attorney and accounting fees) that Buckley may sustain or incur as a result of any claim against Buckley and/or Buyer based upon negligence, breach of warranty, violation of worker’s compensation laws, strict liability in tort, contract, or any other theory of law brought by Buyer, its officers, agents, employees, successors or assigns, by Buyer’s customers, by end users, by auxiliary personnel (such as freight handlers, etc.) or by other third parties, arising out of, directly or indirectly, the use of Buckley’s products or any supplies and equipment purchased by Buyer hereunder or by Buyer’s use of any accessories to Buckley’s products or supplies and equipment purchased hereunder, or by reason of Buyer’s failure to perform its obligations contained herein.

Buyer shall notify Buckley in writing within fifteen (15) days of Buyer’s receipt of knowledge of any claim, accident, or incident involving Buckley’s products or any supplies and equipment purchased hereunder which results in personal injury or damage to property, and Buyer shall fully defend Buckley against any such claim, and shall cooperate with Buckley in its own investigation, if any, and in reaching a determination as to the cause of any such accident or incident, and shall make available to Buckley all statements, reports and tests made or conducted by Buyer or made available to Buyer by others. The furnishing of such information to Buckley and any investigation by Buckley of such claim, incident, accident or information shall not in any way constitute any assumption of liability by Buckley.

RETURN MATERIAL-RESTOCKINGSpecial orders which are not in stock cannot be returned for credit. Buckley-manufactured products such as Curbs, Equipment Supports, Fire Dampers, Buck Duct-Bare and Insulated Buck Duct, Silencers, Security Grilles, Louvers, special manufactured products and others as they arise fall into this category.

Stockable items can only be returned under the following conditions:

1. Prior approval from Buckley along with a copy of the work order or invoice on which the material was sold. (Buckley will in turn issue an RGA number.) Materials will then be either picked up by Buckley or returned prepaid, collect shipments will not be accepted. Also, material must be returned to the sales office that sold you the product. Buckley salespersons are not authorized to pick up goods from customers.

2. Material must be in sellable condition as determined by Buckley inspection.

3. Ten (10%) percent restocking charge for invoices dated less than thirty (30) days earlier. Twenty (20%) percent restock charge for invoices dated over thirty (30) - sixty (60) days. No returns after sixty (60) days.

4. Credit amount to be determined by original selling price. Material returned because of Buckley error will not be subject to restocking charge.

FREIGHT CLAIM PROCEDURES

COMMERCIAL CARRIERS: Under Buckley Associates, Inc. Standard Terms of Sales, shipment made via commercial carriers are shipped F.O.B. Point of Origin. Once the shipment leaves either Buckley’s and/or any of our manufacturers, it is the customer’s responsibility to file the freight claims, according to these terms, titles to the goods and the responsibility to file the claim for the loss and/or damage incurred during transit, pass to the purchaser at the time of the shipment, despite the responsibility for the freight charges (prepaid or collect). Buckley will provide copies of any document in its possession required for proper filing of the claim. Copies of such documents should be requested from the original shipping location. Buckley will also lend any other support to an equitable resolution. However, in providing such support and assistance, Buckley does not assume liability or responsibility for final settlement or collection of any claims.

UPS/FED EX GROUND: UPS/FED EX GROUND freight claims procedure: Notify driver or call local shipping office for inspection of damaged merchandise. Any questions regarding the above “Freight Claim Procedures” should be directed to Buckley Associates Customer Service.

Page 64: Buckley Associates, Inc.buckleyonline.com/catalog/18allcataloglowres.pdfInlet Size CFM Panel Size VPD-HC T-Bar 6 157 24 × 24 1,282. 8 279 24 × 24 1,282. 10 436 24 × 24 1,282. SPD/ASPD

* Not Represented in all Territories

buckleyonline.com | (800) BUCKLEY

Radiant Ceiling Systems Jet Diffusers, Punkah and Nozzle Diffusers

Grease and Odor Mitigation Products for Kitchen Exhaust

Airflow and Zone Controls, Vertical Fan Coils with HR Core

Underground and Preinsulated Duct Systems

Flow Meter Products for Hydronic ChilledWater and Hot Water Applications High-Volume, Low-Speed (HVLS) Fans Heat Recovery Units and Custom Air Handlers Source Capture Products for Vehicle Exhaust

Iris Dampers, FRP Fans, Speciality Fans Variable Frequency Drives Bathroom Ventilation Fans Textile Air Dispersion Products

Electronic Thermal Dispersion Airflow Measurement

Pre-Packaged Custom Penthouses and Air Handlers*

Exhaust and Ventilation Stacks Gas Detection Systems Air Curtains and Air Doors

Venturi Valves, Lab and Healthcare Control Systems

Semi-Custom DX Equipment, Horticultural Growth Facilities, & Custom AHU’s Dust Collection Products

Modulating Draft, Exhaust, and Combustion Air Systems

Gas Detection Systems* Pollution Control Units for Kitchen Exhaust Critical Control Systems for Hospitals and Laboratories

Exhaust and Ventilation Stacks, Zero Clearance Grease Duct

Manual, Remote or Motorized Dampers and Controllers

Car Park Ventilation Systems

Spiral Duct and Fittings

Gas Detection Systems*

Air Filtration Products

Air Distribution - Registers, Grilles and Diffusers, Security Products, Industrial ProductsTerminal and Fan Coil Equipment - Single Duct, Fan-Powered, Flow Control Stations, Horizontal/Vertical FCUsSound Control - Absorptive, Round, Rectangular, Elbow, Custom Silencers, Acoustical Panels and EnclosuresSustainable Design - Active and Passive Beams, Displacement Ventilation, Natural Ventilation, UnderfloorCritical Environments - Venturi Valves and Controls,OR Suites with Access Ceilings, HEPA Diffusers

Fans & Ventilators - Varigreen Motors and Controls, Seismic and Wind-Rated, UL-Listed Smoke Exhaust FansTempered Air Products - Energy Recovery, Dedicated OA Equipment, Indoor Air Handlers, MUA UnitsLaboratory Exhaust Systems - High Plume and Dilution Blowers, Energy Recovery and VAV SolutionsKitchen Ventilation Equipment - Kitchen Hoods, Variable Air Volume Solutions & Controls, Pollution Control UnitsDampers and Louvers - Fire/Smoke Dampers, Control Dampers, Custom Louvers and Finishes

Product Lines We Represent

Air Pear Destratification Fans

Hanover, MA 385 King Street(781) 878-5000

Manchester, NH55 Buckley Circle(603) 669-3566

Gorham, ME 510 Main Street(207) 773-0078

Newington, CT15 Progress Circle(860) 666-0555

Stratford, CT350E Long Beach Blvd

(203) 380-2405

Albany, NY120 Railroad Avenue

(518) 438-7423

Low Dewpoint Dehumidifiation Energy Conservation AHU

Buckley Associates, Inc.