BSS Troubleshooting Guide

download BSS Troubleshooting Guide

of 28

Transcript of BSS Troubleshooting Guide

  • 8/12/2019 BSS Troubleshooting Guide

    1/28

    1 BSC

    2 RNC

  • 8/12/2019 BSS Troubleshooting Guide

    2/28

    3 TRANSMISSION

    4 BTS

  • 8/12/2019 BSS Troubleshooting Guide

    3/28

    OSS connectivity down - both x.25 down

    One X.25 down

    NSEI Down

    BVCI Down

    Zero Voice calls on particular Cell

    Unit re-start

    SIGNALLING LINK OVERLOAD

    SIGNALLING LINK DOWN

    SIGNALLING LINK ACTIVATION OR RESTORATION FAILURE

    SIGNALLING LINK SET DOWN

    GPRS/EDGE LOAD IS VERY HIGH IN PCU OF PSE

    BTS AND TC UNSYNCHRONIZATION CLEAR CALLS ON ABIS INTERFACEWDU FAULTY

    STMU FAULTY

    MCMU RESTART

    BCSU RESTART

    BCSU SWITCHOVER

    Iu-CS link down

    Both Iu-PS links down

    One Iu-PS link down

    BASE STATION FAULTY

    BASE STATION OPERATION DEGRADED

    BASE STATION NOTIFICATION

    CELL FAULTY

    CELL OPERATION DEGRADED

    CELL NOTIFICATION

    BASE STATION LICENCE NOTIFICATION

    BASE STATION TRANSMISSION ALARM

    BEATING WCDMA BTS ALARM

    FAILURE IN WCDMA WBTS O&M CONNECTIONRNW O&M SCENARIO FAILURE

    WCDMA CELL OUT OF USE

    HSDPA CONFIGURATION FAILED

    WCDMA BTS DEDICATED MEASUREMENT FAILURE

    HSUPA FAILURE IN WCEL

    WCDMA BASE STATION OUT OF USE

    BSS TROUBLESHOOTING GUIDE

  • 8/12/2019 BSS Troubleshooting Guide

    4/28

    BFD Down in AXC (Tellabs)

    3G Sites down

    2G or 3G sites down (Mw ring collapsed)

    2G/3G multiple sites down

    SYNCHRONISATION IS MISSING

    Some Subscribers not able to latch on TATA network from specific handsets

    Rx levels differ too much between main and diversity antennas, RSSI detected Rx signal difference exceeding

    EXxx TRX module cooling fan s report no rotation,ESMA System module cooling fan s report no rotation

    ERxx DDU module has detected VSWR above minor limit at anten

  • 8/12/2019 BSS Troubleshooting Guide

    5/28

    S. No. ProblemAlarm No. at

    BSCAlarm Description / Comments Catergory

    2175OSI CLNS LINKAGE NOT

    AVAILABLE

    2175OSI CLNS LINKAGE NOT

    AVAILABLE

    3315

    ALL NETWORK SERVICE

    ENTITIES UNAVAILABLE

    Servicea

    ffecting

    non-Servicea

    ffecting

    Non-

    Service

    affecting

    ng

    Servicea

    ffecting

    OSS connectivity

    down - both x.25

    down

    One X.25 down

    1

    2

    NSEI Down3

  • 8/12/2019 BSS Troubleshooting Guide

    6/28

    13 DISK FAILURE 2860 DISK FAILURE

    Zero Voice calls

    on particular Cell7738

    BTS WITH NO

    TRANSACTIONS

    GPRS/EDGE

    LOAD IS VERY

    HIGH IN PCU OF

    PSE

    Servicea

    ffec

    10SIGNALLING

    LINK SET DOWN

    SIGNALLING

    LINK DOWN8

    11

    9

    SIGNALLING

    LINK

    ACTIVATION OR

    RESTORATION

    FAILURE

    7SIGNALLING

    LINK OVERLOAD

    1072SIGNALLING LINK OUT

    OF SERVICE

    2072

    FAILURE IN SIGNALLING

    LINK ACTIVATION OR

    RESTORATION

    26SIGNALLING LINK LOAD

    OVER THRESHOLD

    5

    4 BVCI Down

    Se

    rvicea

    ffecting

    12

    BTS AND TC

    UNSYNCHRONIZ

    ATION CLEAR

    CALLS ON ABIS

    INTERFACE

    2993

    BTS AND TC

    UNSYNCHRONIZATION

    CLEAR CALLS ON ABIS

    INTERFACE

    2070 LINK SET UNAVAILABLE

    3415GPRS/EDGE LOAD IS

    VERY HIGH IN PCU OF

    PSE

    Service

    affecting

    Non-Service

    affecting

  • 8/12/2019 BSS Troubleshooting Guide

    7/28

    15 STMU FAULTY 2794HW BLOCK FAILURE IN

    PLUG-IN UNIT

    Se

    rviceT

    hreatening

    16 MCMU RESTART2692

    0690,1001

    INCORRECT WORKING

    STATE

    working State Changed ,

    Unit restarted

    ServiceT

    hreatening

    WDU FAULTY 2861, 2692

    NO ACCESS TO DISK

    ,INCORRECT WORKING

    STATE

    non-Servicea

    ffecting

    14

  • 8/12/2019 BSS Troubleshooting Guide

    8/28

    17 BCSU RESTART

    2692

    0690

    1001

    INCORRECT WORKINGSTATE

    working State Changed ,

    Unit restartedServicea

    ffec

    ting

    18BCSU

    SWITCHOVER

    2692

    0690

    1001

    INCORRECT WORKING

    STATE

    working State Changed

    Unit Restarted

    ServiceT

    hreatening

    19

    Loss of

    Synchronization

    in BSC

    2,641Failure in

    Synchronization Signal

    ServiceT

    hreatening

  • 8/12/2019 BSS Troubleshooting Guide

    9/28

    Affect / Steps to be follow for troubleshoot

    1. Check the signalling links states at MSS end. s gna ng n s n se own means

    -3. Send local engineer at BSC site

    4. Check BSC end Mux status & alarm. 1st: Mux

    unmanaged - check alarm at connected Mux, Powerissue at BSC site. 2. Mux managed - check alarm at

    Mux & verify the power status for BSC.

    5. Login BSC via VDU / LANU. Check the alarms &

    current computer unit status, if login is possible.In

    case login is not possible ,get login through OMU CPU

    and check the status of OMU and other computer

    units.If we will not get the login through OMU also

    ,raise the emergency and follow steps as per with

    care team recommandation.

    1. Check the signalling links states at MSS end. ,

    3. Check the Transmission path - Is there any alarm in

    X.25 E1 path / path broken, then re-route path &

    check X.25 links status.

    5. If media ok, Send local engineer at BSC site.

    7. If BSC not login via VDU / LANU than login through

    CPU of OMU unit and check the status: after login ask

    for password then login ok, or if continuously

    restarting phase means OMU unit faulty. Do as per

    care team recommendations.

    1. Check the Transmission path - Is there any alarm in

    X.25 E1 path / path broken.. ec e a arms. o en rese e .

    Data traffic affect, down

    Check no. of NESI's down, if down all - Trace PCU IP

    from SGSN & find last hop address & check media

    B/W that hop to BSC

    If only some NSEI down (one or two) follow below

    steps

    1. Check the PCU - BCSU combination

    2. Ping SGSN (PAPU) IP from that BCSU-PCU

    3. Trace PCU IP from SGSN

    4. Shift the traffic (DAP) to other PCU-BCSU. ur ng rs agnose a . . agnose o

    Data traffic affect, down

    1. GENA toggle & check status.

  • 8/12/2019 BSS Troubleshooting Guide

    10/28

    2. Check PCU-BCSU combination: a n case a par cu ar - com na on: s

    - -

    - -(c) BCSU switchover.

    (d) PAPU re-set / switchover .

    Check hardware, cabling & commissioning

    A signalling link has failed and changed state from IN

    SERVICE to OUT OF SERVICE, or its initial alignment

    attempt has failed.

    Check the Transmission path ere are o er pa ava a e, s gna ng n s pa

    -

    The activation or restoration of a signalling link fails.

    Signalling transmission capacity decreased.

    Check the Transmission path ,

    -All signalling links in the signalling link set are

    - .

    ec or e en o en connec v y or e ers

    Check GPRS/EDGE load & balance the load by

    reallocate the DAPs

    Impact: Call drop, Quality degradation, Call muting

    ,

    e sys em as e ec e a ser ous error a may

    have been caused by the hard disk or the SCSI

    controller plug-in unit breaking down.Saving data into

    the hard disk or reading data from the hard disk

    Check UP/DL quality, path imbalance/VSWR/RSSI

    This notice appears repeatedly - consider adding more

    signalling links

    ,

    timeslot mapping between bts and bsc should be

    checked. if mapping is fine, timeslot bypassing should

    be checked for the problem BTS/TRX, and if it iscoming on more than one timeslot, and everything

    else is fine, trx should be replaced and call test should

    be done on all time slots after replacement. If it is

    Thershold value need to be change or PCU addition

    require if load balancing ok.

  • 8/12/2019 BSS Troubleshooting Guide

    11/28

    Impact: No hard disk Redundancy, Measurements

    might be affected.

    1. Check the status of STMU with ZUSI:STMU:;

    commands. Check the current & History alarms &

    Site/aters outage if any related to faulty STMU.

    2. Check the supplementary information of alarms &

    work as per information .

    3. Clear the faulty tag with ZUST command and

    observe.

    4. Check the alarms of ET/ transmission and set loss

    with ZYWI command.

    5. Temperature condition need to check at BSC

    location.

    6. Check the STMU cabling and if required replace the

    Hardware.

    1. Check the status of computer units with

    ZUSI:COMP:; commands. Check the current & History

    alarms.

    2. Check the supplementary information of alarms &

    work as per information (switchover / diagnose).

    3. check ZIGO & ZUDH.

    4. Change the state of MCMU to SE-NH and perform

    the JOJI of all cards og MCMU and GSW .after

    Diagonise the unit and check.

    4. if problem repeates on same MCMU ,replace the

    hardware with help of alarm info.

    5. Perform the diagonistics of that MCMU /EMB and

    make it in working State.

    6. If no alarm found or problem occur on different -

    different units with same alarm Number it may be a

    SW bug.

    Note : Kindly note before switchoff the MCMUrespective MCMU and EMB should be in SE-NH state

    also during any hardware replacement check the

    Jumper setting of the card.during any hardware

    replacement check the Jumper setting of the card.

    . ec e s a e w :; comman s . arm

    history and current alarm should be checked. If it is

    one WDU or both WDU are in BL-SY state .

    2. Perform the JOJI of harddisk ( with JOJI the HDSAM

    ) and DCAR card .perform the OMU restart and check

  • 8/12/2019 BSS Troubleshooting Guide

    12/28

    1. Check the status of computer units with

    ZUSI:COMP:; commands. Check the current & History

    alarms.

    2. Check the supplementary information of alarms &

    work as per information (switchover / diagnose).

    3. check ZIGO & ZUDH.

    4. if problem repeates on same BCSU ,replace thehardware with help of alarm info.

    5. Perform the diagonistics of the BCSU with both

    MCMU and make it in working State.

    6. Check the BVCI state and lapd States

    7. If no alarm found or problem occur on different -

    different units with same alarm Number it may be a

    SW bug.

    Note : During any hardware replacement check the

    Jumper setting of the card accordingly.

    1. Check the status of computer units with

    ZUSI:COMP:; commands. Check the current & History

    alarms.

    2. Check the supplementary information of alarm &

    work as per information (switchover / diagnose).

    3. check ZIGO & ZUDH.

    4. if problem repeates on same BCSU ,replace the

    hardware with help of alarm info.

    5. Perform the diagonistics of the BCSU with both

    MCMU and make it in working State.

    6. Check the BVCI and Lapd state.

    7. If no alarm found or problem occur on different -

    different units with same alarm Number it may be aSW bug.

    Note : During any hardware replacement check the

    Jumper setting of the card accordingly.

    1. Check the ZDRI :; command output with Current

    alarms.

    2. Check the ET alarms on Sync ET .

    3. Disconnect the all sync with ZDRC command

    ,setthe ossilator control word value to 32000 on both

    CLS and reconnect the all sync inputs with correct

    priority.

    Note : If any BSC is out of Sync ,there will be slip on allETs of that BSC .

  • 8/12/2019 BSS Troubleshooting Guide

    13/28

    S. No. ProblemAlarm No.

    at RNC

    arm

    Description / Cateagory Impact

    4

    BASE STATION

    FAULTY7650

    No connection

    to Flexi

    transport

    submodule

    SA Transmission to NodeB will be affected

    BTS reference

    clock missingSD

    Service will be affected based on the

    degradtion threshold level

    BTS RNC/I-

    HSPA interface

    signalling linkfailure

    SA NBAP/AAL2 signalling link failure

    System module

    failureSA

    NodeB Capacity may be reduced/NodeB

    totally may not be opreational

    3

    LINK SET

    UNAVAILABLE

    SA

    NSA No Data traffic outage

    LINK SETUNAVAILABLE SA RNC Total Outage

    LINK SET

    UNAVAILABLE RNC data traffic outage

    5

    One Iu-PS link

    down2070

    BASE STATION

    OPERATION

    DEGRADED

    7651

    1 Iu-CS link down 2070

    2Both Iu-PS links

    down2070

  • 8/12/2019 BSS Troubleshooting Guide

    14/28

    BTS requires

    restart because

    license status

    has changed

    SA Mentioned licence feature will not work

    BTS time not

    corrected

    NSA BTS time will not be correct

    Difference

    between BTS

    master clock

    and reference

    frequency

    NSABTS frequecy deviates from IuB

    referecne

    Fan failure NSA Temparature will be increased

    Heatingelement not

    working

    SA

    Heating from the heating element is

    not available. The module temperature

    may not reach the working level or

    may reach it very slowly

    Temperature

    alarmSA

    Depending on severity BTS Capacity

    may be reduced/BTS totally may not be

    opreational

    Failure inoptical RP3

    interface

    Depending on severity BTS Capacitymay be reduced/BTS totally may not be

    opreational

    Incompatible

    SW version

    detected

    Depending on severity BTS Capacity

    may be reduced/BTS totally may not be

    opreational

    RF module

    failure

    Sectors will be affected depends on

    severity

    VSWR alarm

    Depending on severity BTS Capacity

    may be reduced/BTS totally may not be

    opreational

    RF module

    failureSA Sectors Operation will be degraded

    Rx signal level

    failureNSA Sectors Operation will be degraded

    SA

    8CELL OPERATION

    DEGRADED7654

    CELL FAULTY 7653

    6

    7

    BASE STATION

    NOTIFICATION7652

  • 8/12/2019 BSS Troubleshooting Guide

    15/28

    9

    CELL

    NOTIFICATION7655

    Radio resources

    switched offSA Cell will be down

    HW capacity

    too low for

    feature 308,

    Licence BasedBTS channel c

    NSA

    The licenses are granted but cannot be

    used. Some of the licensed features are

    not available.

    Licence missing

    00000001125,

    Flexi WCDMA

    BTS 60W Power

    License

    SA Sector down

    Licence missing

    0000000306,

    HSDPA 16QAM

    SW Licence

    Support

    SA SDPA Traffic will affect

    Licence missing

    0000000307,

    HSDPA

    Proportional

    Fair Resource

    Pac

    NSA Degradation

    Licence missing

    0000000649,

    Shared HSDPA

    Scheduler for

    Baseband

    NSA Degradation

    Verification of

    target ID failed3 times.

    SA Degradation of system module

    License missing

    for feature

    Additional 2 E1,

    T1, JT1

    interface o

    Service Degraded

    SA

    7661

    BASE STATION

    TRANSMISSION

    ALARM

    7665

    10

    11

    BASE STATION

    LICENCE

    NOTIFICATION

  • 8/12/2019 BSS Troubleshooting Guide

    16/28

    License missing

    for feature

    UBR+.

    Cell Down

    12

    BEATING WCDMA

    BTS ALARM7740 (blank) NSA Repeatation of any alarm causes

    13

    FAILURE INWCDMA WBTS

    O&M

    CONNECTION

    7750 (blank) NSABTS Cannot be logined remotly &

    Measurements will not be updated

    AAL2 path

    unblock not

    accomplished

    Cell Down

    BCCH

    information

    updating has

    failed

    Cell Down

    Common

    channel

    deletion has

    failed

    Cell Down

    NBAP interface

    type unknown

    failure

    Cell Down

    Block resourcerequest, normal

    priority

    Sector down

    Common

    measurement

    failure scenario

    Sector down

    NBAP link

    failureSector down

    Resource statusindication, cell

    disabled

    Sector down

    WCEL state not

    WOSector down

    WCEL state not

    WO after setupWhen Site Down Or Sector Down

    SA

    SA

    RNW O&M

    SCENARIO FAILURE7761

    WCDMA CELL OUT

    OF USE7771

    14

    15

  • 8/12/2019 BSS Troubleshooting Guide

    17/28

    RNC internal

    errorService Degraded

    WBTS rejects

    the

    configuration

    Service Degraded

    17

    WCDMA BTS

    DEDICATED

    MEASUREMENT

    FAILURE

    7778 SA DCN state - Disable Or Cell Faulty

    A unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    A unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    A unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    19

    WCDMA BASESTATION OUT OF

    USE

    7786 (blank) SA WBTS will be down

    16

    18 SA

    SD

    HSDPA

    CONFIGURATION

    FAILED

    7772

    HSUPA FAILURE IN

    WCEL7780

  • 8/12/2019 BSS Troubleshooting Guide

    18/28

    Possible Causes Solution

    ects: ommunication wit

    1. Check the unit status for any

    failure and check the current

    and histor alarms. ing trace contro p ane an

    . ec ssoc a on se an

    4. Check connectivity B/W end trace

    IP to MSS.ec s: ommun ca on w o

    1. Check the unit status for any

    failure and check the current

    and history alarms. ng race con ro p ane

    . ec ssoc a on se an

    . ec connectivity en trace

    Affects: Communication with one

    1. Check the unit status for any

    failure and check the current. ng race con ro p ane

    . ec ssociation set an

    . e c connec v y en race

    Malfunction of Transport Module in

    System Module

    Reset System Module/Replace

    Transport Module in System Module

    Site Clock E1 having errors / AISClock E1 Interface needs to be check

    & Check the SYNC of TXN side

    Transmission break or fluctuationsCheck transmission configurations

    and paths

    Abnormal functioning of FSM Reset FSM/Replace FSM

    Affect / Steps to be follow for troubleshoot

  • 8/12/2019 BSS Troubleshooting Guide

    19/28

    After licence installation BTS not

    given restartRestart BTS.

    NTP Server IP mismatchCheck NTP server IP it should be

    same as RNC OMS IP

    DAC Valure variations Set DAC value to standard value

    H/W FaultyCheck working status of Fans or

    replcae FAN units in FSM

    The heater control connection of theFSM is faulty, there is no heater or

    the heater is faulty.

    Check whether the heating element

    exists at all./ Check the heatercontrol connection and that the

    heater is working./ Replace the

    alarming component.

    The internal temperature of the RF

    Module or System Module exceeds

    the threshold value, or the ambient

    temperature of the module(s) is

    outside the specified limits.

    Check the FAN units in FSM/FRGP

    Abnormal/ failure in optical cable

    between FSM & FRGP

    Check the Optical cable connectonbetween FSM & FRGP/Reset

    FSM/Replace cable.

    SW Mismatch of BTSRecomission BTS with Correct SW

    version

    Abnormal functioning of FRGPReset FRGP/FSM/Check interface

    cables/Replace FRGP

    High VSWRCheck the VSWR, should be less than

    1.3

    Abnormal functioning of FRGPReset FRGP/FSM/Check interface

    cables/Replace FRGP

    The RX signal level is less than -

    112dBm or the difference between

    the maximum and minimum power

    levels of all RX antennas in the same

    cell and sector is more than the limit

    (4 dB).

    Check the VSWR & Antenna cables

  • 8/12/2019 BSS Troubleshooting Guide

    20/28

    As per configuration H/W

    mismatch/unavailability

    Check the cell configration & H/W

    availbilty at site

    The HW capacity is too low to

    support all licenses of an optional

    feature.

    Call to GNSC CM Delete the licenses

    or insert new hardware.

    During NodeB commissioning seleted

    60W power for sector.

    Login to nodeB and change

    parameters of sector power to 20W

    HSDPA License Missing Or Cell Down Call to GNSC CM get it clear

    License missing License missing

    License missing License missing

    Hanged/config issue/comm issue Hanged/config issue/comm issue

    This basic license missingGNSC has to load this basic license

    from Netact

  • 8/12/2019 BSS Troubleshooting Guide

    21/28

    HSDPA License MissingGNSC has to load this basic license

    from Netact

    Repeatation of any alarm causesCancels once causing Alarm is

    cleared

    DCN Configuration mismimatch in

    NodeB/RNC/tellabs

    To be checked DCN Configrations at

    RNC/NodeB/Tellabs

    CoCo/ATM Configuration Mismatches

    between NodeB/RNC/Tellabs

    To be checked CoCo/ATM

    Configuration Mismatches between

    NodeB/RNC/Tellabs

    CoCo/ATM Configuration Mismatches

    between NodeB/RNC/Tellabs

    To be checked CoCo/ATM

    Configuration Mismatches between

    NodeB/RNC/Tellabs

    CoCo/ATM Configuration Mismatches

    between NodeB/RNC/Tellabs

    To be checked CoCo/ATM

    Configuration Mismatches between

    NodeB/RNC/Tellabs

    CoCo/ATM Configuration Mismatches

    between NodeB/RNC/Tellabs

    To be checked CoCo/ATM

    Configuration Mismatches between

    NodeB/RNC/Tellabs

    Cell Down Need to check WCELL/WBTS alarm

    Cell Down Need to check WCELL/WBTS alarm

    Cell Down Need to check WCELL/WBTS alarm

    Cell Down Need to check WCELL/WBTS alarm

    Cell Down Need to check WCELL/WBTS alarm

    Cell Down Once Node-b is up, alarm will clear

  • 8/12/2019 BSS Troubleshooting Guide

    22/28

    Cell Down / Interface Down Or H/W

    configuration In Node-B

    Node-B Lock & Unlock Or Restart

    Node-B / Cross check & Rectify

    Node-B H/W Configuration --All This

    action based on Sublimentory

    information of Alarm

    Cell Down / Interface Down Or H/W

    configuration In Node-B

    Node-B Lock & Unlock Or Restart

    Node-B / Cross check Node-B H/W

    Configuration --All This action based

    on supplementary Alarm Info.

    DCN connected E1 Interface needs to

    be cross check

    DCN Interface / Lock all the cells

    under the BCF and delete & Re-

    create COCO configuration and

    unlock all the cells / If required Site

    reset has to be given ( Anlaysis based

    on supplementary info)

    Cell DownA unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    Cell DownA unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    Cell DownA unit (or units),taking care of HSUPA

    traffic in the WCEL can be faulty

    CNBAP/BRM BreakCheck the transmission path &Configuration between NodeB to

    RNC

  • 8/12/2019 BSS Troubleshooting Guide

    23/28

    S. No. Problem Alarm No. at BSC Alarm Description / Comments Catergory

    5 M/W Link Problem

    No Alarm observed in the

    link, except RSL dip at one

    end.

    At one end, RSL of the link is OK, on

    other end it dips to -90dBm.

    No typical alarm observed in the link.

    ServiceT

    hreatning

    32G or 3G sites down

    (Mw ring collapsed)

    Service

    affecting

    42G/3G multiple sites

    down

    Service

    affecting

    Fault rate monitoring & PCM failures

    Fault rate monitoring & PCM failures

    1BFD Down in AXC

    (Tellabs)

    Service

    Degradation

    2 3G Sites downService

    affecting

    7665 BFD down

    Base Station out use

  • 8/12/2019 BSS Troubleshooting Guide

    24/28

    Affect / Steps to be follow for troubleshoot

    BFD down or fluctutating in AXC & data traffic shifted to ATM,

    Cause HSPA fallback enabled. Checked txn media as well as ISA

    card or reset Mux ISA card to restore BFD.

    Need to check utilization of GE ports, If broadcast packets incresing

    then need to check the txn- media & ISA card.

    Deimplement trails for culprits ISA & raplace ISA ASAP.

    Downs sites need to be check belongs particular AXC card or Mux

    particular STM-1 port. Need to check alarms on port, If any alarm

    appears then switch to redundant port to restore sites

    If the CPU utilization for both Main & Spare IFMcard are hign then

    remove one by one & inserted Main card to reduce CPU utilization.

    Atlast switched CDC card from main to redundant card.

    Need to check alrams on ALU mux port during ring collapsed at

    both end.

    Need to ping connecting IDU from GNOC to check alarms & w.r.t

    appeared alarms we identify either power issue or hardware fault

    Enginners need to send at site with hardware for further trouble

    shooting.

    Sites need to be indentified on particular MUX

    Core mux malfunctioning at BSC/RNC location

    2G & 3G site database shared with all CTLs

    Impact: Microwave Link gets down

    Reason of the problem: Normally in this type of scenario, ODU of

    the link (at the end where RSL is OK) is misbehaving.

    Its transmitor gets off, stops

    radiating. But, it receives the signal properly.

    Troubleshooting: ODU to be replaced

  • 8/12/2019 BSS Troubleshooting Guide

    25/28

    S. No. Problem BTS Type Alarm

    No. at

    BSC

    Alarm Description / Comments

    2 a)Some Subscribers were not able

    to latch on TATA network from

    specific handsets.While Same

    Handsets were running fine with

    IDEA or any other operator from a

    perticular site

    (N_UW_NRA_001,Muzzafarnagar)

    Flexi Edge

    BTS

    Observation:At Problematic

    location/Premises(N_UW_NRA_001,Muzzafa

    rnagar) there are two NSN equipments

    serving for IDEA/TATA.No alarm was found

    on problematic site.

    3 Rx levels differ too much between

    main and diversity antennas, RSSI

    detected Rx signal difference

    exceeding threshold

    Flexi 7607 Rx levels differ too much between main and

    diversity antennas,

    RSSI Value is high than 10.

    1 SYNCHRONISATION IS MISSING

    All External Q1 device fail to

    respond

    Flexi/MR 7787 DFCA not working in that particular Site,One

    more Observation:Site will continously

    restart when DFCA is enabled in the site

    5 a)ERxx DDU module has detected

    VSWR above minor limit at anten

    Flexi/MR 7607 VSWR limit is high than 1.5 for Minor alarm

    and >2.7 for major alarm

    4 EXxx TRX module cooling fan s

    report no rotation,ESMA System

    module cooling fan s report no

    rotation

    Flexi 7607 TRX cooling fan not rotate

    ESMA cooling Fan not rotate

  • 8/12/2019 BSS Troubleshooting Guide

    26/28

  • 8/12/2019 BSS Troubleshooting Guide

    27/28

    Catergory Affect / Steps to be follow for troubleshoot

    Service affecting Activities steps as follow:-

    1.Firstly we Check Infra condition of the site

    2.Check the BTS configuration of the site ,properly check weather there is

    any alarm in site,But no service affecting/Service degrading alarm found

    3.After that we check DAC value,RSSI comparision value and VSWR value

    with Site master but problem not resolved.

    4.Change the PLMN allowed from 1 upto 7.

    5.Replaced the ESMA card.

    6.Shift BCCH to another TRX and check

    7.Shift BCCH to another TRX and check.

    8.Swapping of TRX's from other perfet site to problamatic site and

    check.

    9.Site deletion and further recreation done still no improvement found

    10.Rehome the site BCF-22 Muzaffarna ar BSC to Meerut -1 BSC with

    1.First step to check the site is down or not (ZEOL)

    2.if site is working with DFCA unsync and LMU is in stand by mode (ZEFL)

    than visit the site

    3.Check the parameters such as LMU area parameter,DFCA disabled orenabled

    4.Check ESLA cable connectivity between ESMA to LMU ,if found any

    Service

    Degrading

    1.Check the RSSI measurements with BTS Manager.

    2.Check the BTS RF cables and connections.Check the antenna and RX

    cabling.

    3.If the antenna and RX cabling are faulty, correct the problem and run

    TRX test to cancel the alarm.

    4.Check and measure VSWR of the antenna lines.

    Service affecting

    1.90% there is a chance of Over heating or Room tempurature high inside

    shelter

    2.if there in an issue of tempurature resolve the issue along with IP

    3.Check that the fan unit cable is correctly connect to DTRX/ESMA

    4.Check that there are no obstacles preventing the fan(s) from rotating

    5.Clean the fan unit of dust and/or dirt

    6.if problem is still presist then Replace the fan unit

    service affecting 1.Measure VSWR value with Site Master ,If value is found high then

    second step is to see the fault via Distance to fault location .

    2.According to distance found, replace connector,Jumper ,Anteena ordamaged feeder cable

    3.With external test equipment check VSWR of the antenna line. Repeat

    step 1 if the measurement is again high

    Service

    Degrading

    D:\userdata\alekar\Desktop\BSS Fault

  • 8/12/2019 BSS Troubleshooting Guide

    28/28

    BCF Alarm Guide

    l l