BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

270
DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSC Copyright 2013 Nokia Solutions and Networks. All rights reserved. CONFIDENTIAL APPROVED 1.14 1 (270) BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSC Release Delivery: HW Upgrade Product Family: Radio Controllers Product: BSC3i 1000/2000, Upgraded Flexi BSC Release: S16 onwards Approval date: 12-Dec-2012 Nokia Solutions and Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Solutions and Networks for additional information.

description

BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

Transcript of BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

Page 1: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

1 (270)

BSC Implementat ion forETP/ETP-A in BSC3i1000/2000, UpgradedFlexi BSCRelease Delivery: HW UpgradeProduct Family: Radio ControllersProduct: BSC3i 1000/2000, UpgradedFlexi BSCRelease: S16 onwards

Approval date: 12-Dec-2012

Nokia Solutions and Networks is continually striving to reduce the adverse environmental effects of itsproducts and services. We would like to encourage you as our customers and users to join us inworking towards a cleaner, safer environment. Please recycle product packaging and follow therecommendations for power use and proper disposal of our products and their components.

If you should have questions regarding our Environmental Policy or any of the environmental serviceswe offer, please contact us at Nokia Solutions and Networks for additional information.

Page 2: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

2 (270)

Table of Contents1 Purpose .................................................................................................................................................. 52 Scope of applications .............................................................................................................................. 63 Using the document ................................................................................................................................ 7

3.1 General info ....................................................................................................................................................... 73.2 Upgrade macro .................................................................................................................................................. 8

3.2.1 Structure ...................................................................................................................................... 83.2.2 Communication ............................................................................................................................ 8

4 Introduction ........................................................................................................................................... 105 Pre-requirements .................................................................................................................................. 12

5.1 Pre-requirements & Actions needed prior upgrade ............................................................................................ 125.2 Restrictions ..................................................................................................................................................... 125.3 Needed documentation .................................................................................................................................... 125.4 Needed equipment .......................................................................................................................................... 135.5 HIT and upgrade macros.................................................................................................................................. 13

5.5.1 System requirements for HIT ...................................................................................................... 135.5.2 Installing HIT .............................................................................................................................. 135.5.3 Installing HIT upgrading macros .................................................................................................. 135.5.4 HIT settings................................................................................................................................ 135.5.5 Connection settings .................................................................................................................... 145.5.6 Starting the HIT application / macro execution ............................................................................. 26

6 Fallback copying of the current package ................................................................................................ 327 BSC configuration printout (pre-check) .................................................................................................. 338 Licence installation and feature activation .............................................................................................. 349 ETPLAN CONFIGURATION .................................................................................................................. 35

9.1 Make SWU units to passive state ..................................................................................................................... 359.2 Make SWU units to SE-NH state ...................................................................................................................... 369.3 Cabling changes .............................................................................................................................................. 36

9.3.1 For initial BSC 3i 1000/2000 ....................................................................................................... 369.3.2 Upgraded flexi BSC-Upgrades from BSC3i 1000/2000(initial) ...................................................... 389.3.3 Upgraded flexi BSC-Upgrades from BSC3i 1000/2000( 660 initial) ............................................... 429.3.4 Upgraded flexi BSC-Upgrades from BSC3i 660(initial) ................................................................. 48

9.4 Change topology ............................................................................................................................................. 549.5 Configure SWU 6 and 7 to the HW database .................................................................................................... 54

9.5.1 For BSC 3i 1000/2000 ................................................................................................................ 549.5.2 For Upgraded Flexi Single cabinet / Double cabinet ..................................................................... 54

9.6 Check internal LAN index with command .......................................................................................................... 549.7 Add SWUs to the internal LAN: ........................................................................................................................ 549.8 Change all SWUs state to the WO-EX .............................................................................................................. 559.9 Activate all SWU s back to use ......................................................................................................................... 55

10 Create ETPSIG-I IP address to MCMU and BCSU ................................................................................ 5511 Packet Abis over Ethernet(ETPE), PIU type ETP ................................................................................... 56

11.1 Creation of ETPE unit with transmission/line protection ..................................................................................... 5611.1.1 Install Plug-in units, terminators and cables ................................................................................. 5711.1.2 Create HW configuration ............................................................................................................ 7311.1.3 Check Plug-in unit software ........................................................................................................ 7711.1.4 Diagnostic .................................................................................................................................. 8011.1.5 Check PCU configuration ........................................................................................................... 80

11.2 Creation of ETPE unit with hardware protection ................................................................................................ 8011.2.1 Install Plug-in units, terminators and cables ................................................................................. 8111.2.2 Create HW Configuration .......................................................................................................... 11211.2.3 Check Plug-in unit software ...................................................................................................... 11711.2.4 Diagnostic ................................................................................................................................ 12011.2.5 Check PCU configuration ......................................................................................................... 120

12 Packet Abis over TDM (ETPT), PIU type ETP...................................................................................... 12112.1 Creation of ETPT unit with transmission/line protection. .................................................................................. 121

Page 3: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

3 (270)

12.1.1 Install Plug-in units, terminators and cables ............................................................................... 12112.1.2 Create HW configuration .......................................................................................................... 14312.1.3 Check Plug-in unit software ...................................................................................................... 15112.1.4 Diagnostic ................................................................................................................................ 15412.1.5 STMU s to WO-EX state ........................................................................................................... 15412.1.6 Check PCU configuration ......................................................................................................... 155

12.2 Creation of ETPT unit with hardware protection .............................................................................................. 15512.2.1 Install Plug-in units, terminators and cables ............................................................................... 15512.2.2 Create HW configuration .......................................................................................................... 19212.2.3 Check Plug-in unit software ...................................................................................................... 20312.2.4 Diagnostic ................................................................................................................................ 20612.2.5 STMU s to WO-EX state ........................................................................................................... 206

13 A over IP (ETPA), PIU type ETP-A ...................................................................................................... 20713.1 Creation of ETPA unit .................................................................................................................................... 207

13.1.1 Install Plug-in units and cables .................................................................................................. 20713.1.2 Create HW configuration .......................................................................................................... 21413.1.3 Check Plug-in unit software ...................................................................................................... 21513.1.4 Diagnostic ................................................................................................................................ 218

14 A over IP (ETPA), PIU type ETP .......................................................................................................... 21914.1 Creation of ETP(A) unit .................................................................................................................................. 219

14.1.1 Check the source configuration for overlapping Plug-in units...................................................... 21914.1.2 Deleting the interface and unit In case the upgrade is done to swap existing ETP-A withETP 21914.1.3 Install Plug-in units and cables .................................................................................................. 21914.1.4 Create HW configuration .......................................................................................................... 23214.1.5 Check Plug-in unit software ...................................................................................................... 23514.1.6 Diagnostic ................................................................................................................................ 238

15 Copy the HW equipment database information to the disk (DBC) ......................................................... 23916 Actions after upgrade & Post conditions .............................................................................................. 240

16.1 BSS Integration ............................................................................................................................................. 24016.2 BSC configuration printout (post-check) .......................................................................................................... 24016.3 Return to the old HW configuration ................................................................................................................. 240

17 Appendix : ........................................................................................................................................... 24117.1 Appendix 1: SW 256B Dip switch settings ....................................................................................................... 241

17.1.1 SW256B jumper settings .......................................................................................................... 24117.1.2 PCM mode settings (SW1) ....................................................................................................... 24117.1.3 Interchangeability code settings (SW2) ..................................................................................... 24217.1.4 Serial Broadband SB1 settings (SW3) ....................................................................................... 24317.1.5 Serial Broadband SB2 settings (SW4) ....................................................................................... 24417.1.6 Serial Broadband SB3 settings (SW5) ....................................................................................... 24717.1.7 Serial Broadband SB4 settings (SW6) ....................................................................................... 249

17.2 Appendix 2: GTIC & ETC PCM usage in case of BSC3i 1000/2000 ................................................................. 25017.3 Appendix 3: GTIC & ETC PCM usage in case of Upgraded Flexi ..................................................................... 25617.4 Appendix 4: Update ESBs with latest software ................................................................................................ 263

17.4.1 Update ESB Software............................................................................................................... 26317.4.2 Enabling or disabling the automatic loading of configuration files ............................................... 263

17.5 Appendix 5: ETP/STMU strapping settings. .................................................................................................... 26417.5.1 ETP-A C111828 ....................................................................................................................... 26417.5.2 ETP C111826 .......................................................................................................................... 26517.5.3 ETS2 ....................................................................................................................................... 267

17.6 Appendix 6: ETP username & password settings ............................................................................................ 268

Contact:

Contact your local Nokia Solutions and Networks support

Summary of changes:

Page 4: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

4 (270)

01-Dec-2012 0.1 Creation date12-Dec-2012 1.0-0 Approval date21-Dec-2012 1.1-0 Added PIU update for mate STMUs in chapters 12.1.5

and 12.2.5.Added new notes regarding A over IPLicense in chapters 8, 13.1.4 and 14.1.6.Removedchapters 9.4 and 9.11 as part of CR1004implementation

16-Jan-2013 1.2-0 Added CR75 details01-Feb-2013 1.3-0 Added connection settings for Linux in chapters 5.5.5.218-Feb-2013 1.4-0 Added note regarding COM issue in HIT3.3 in chapter

5.5.5.1.2 and 5.5.5.2.227-Feb-2013 1.5-0 Added note on IUA messaging configuration for all ETP

variants04-Apr-2013 1.6-0 Removed note regarding COM issue from chapters

5.5.5.1.2 and 5.5.5.2.2.Also updated the hit version as3.4-0.Updated appendix 6

19-Jun-2013 1.7-0 Updated Appendix 17 PCM mode settings (SW1) forupgraded flexi BSC

02-Jul-2013 1.8-0 Updated chapter 1026-Sep-2013 1.9-0 Template update16-Jan-2014 1.10-0 PR 105650ESPE01 "SW256B settings for BSC3i

1000/2000 missing text in BSC Implementation forETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSC"corrected

21-Feb-2014 1.11-0 Updated appendix 17.1: SW 256B Dip switch settings.Added note “Create the PEP link to ETPGID 0 first ifyou want to get the ETP object ID for the ETPGID tomatch in NetAct” in chapter 11.1.2, 11.2.2, 12.1.2 and12.2.2.

20-Mar-2014 1.12-0 Updated note in chapter 5.409-Sep-2014 1.13-0 ETPE 2-1 and 3-0 and 3-1 added to the table on page

84: For BSC 3i 2000/Upgraded Flexi double cabinet.CABID and CARID terminators details added in chapter12.2.1.1: Terminators and setting modules.

23-Oct-2014 1.14-0 Chapter 9.4 updated.

Page 5: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

5 (270)

1 PURPOSE

This document describes the implementation of ETP/ETP-A plug-in unit to the BSC environment. This documentdoes not support Combined TCSM3i part. That upgrade can be handled with “TCSM implementation forETP/ETP-A” procedure.This document can be used with following environments:

BSC3i1000/2000 (initial delivery or upgraded) FlexiBSC3000 (upgraded) FlexiBSC4200 (upgraded)

Page 6: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

6 (270)

2 SCOPE OF APPLICATIONS

The BSC implementation for ETP ETPA in BSC3i 1000/2000, Upgraded Flexi BSC is available for BSC3i1000/2000 or Upgraded Flexi BSC 3000/4200 in S16 release onwards.The procedure cannot be executed without traffic interruption. Traffic must be moved from concerningETS2/ET16/ETIP plug-in unit before the actual upgrade.Procedure must be performed locally at BSC site.

Page 7: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

7 (270)

3 USING THE DOCUMENT

3.1 General info

The BSC implementation for ETP/ETP-A can be done using the HIT (Holistic Integration Tester) software tool.Optional way is to make the upgrade manually by following this documentation.

The SWU6 and SWU7 upgrade is done manually with the HIT macro. However procedure must be performedlocally at BSC site as there are cabling changes and IP address reallocation.

The HIT software automates most of the tasks necessary for the software or hardware upgrade. The HIT softwareand the instructions are included in this manual. It is recommended that the HIT User's Manual is gone throughbefore starting the program.

When using the HIT for upgrading BSC, these instructions should be followed for a more detailed description ofthe different phases, which take place during the upgrade. The upgrade macro menu dialog is designed to followclosely this document.

NOTE: The commands executed by the HIT macro do not always match exactly with the commandspresented in the manual. This is because sometimes the automated tasks of the HIT macro require morecommands and different command syntaxes, than are presented in the manual.

When using the HIT, the MML commands are executed automatically. It is not necessary to type any commandsuntil it is specifically requested by HIT.

Page 8: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

8 (270)

3.2 Upgrade macro

3.2.1 Structure

All the SW & HW macros are gathered under one main macro (UPGMAIN.HIT), from which the wanted SW / HWupgrade can be selected. Regardless of which macro (SW or HW upgrade) is wanted to run, the user alwaysstarts with the same main macro.Example of macro structure:

UPGMAIN.HIT Select wanted upgrade:

o SOFTWARE UPGRADES SW upgrade S15 -> S16

…o HARDWARE UPGRADES

HW upgrade 1 HW upgrade 2

Under each upgrade / tool there is a upgrade specific menu which describes the steps which can be executedindividually:

SW upgrade S15 -> S16 (selected from main menu) Select wanted step

o Make fallbacko Check Firmwareo Make pre-checko Copy SWo …o

When a step is completed successfully, the user is brought back to upgrade menu and a “Done.” -sign will appearat beginning of the name of the step. If step execution fails for some reason, macro stops and user can correctthe error manually and then continue macro execution normally.

If macro or computer freezes totally during step execution and macro needs to be restarted, user cannot re-runthe incomplete step from the menu. In this case, the user must complete that certain step manually, using thisdocumentation as guide. When the step has been completed manually, user can continue the macro executionfrom next available step. Note, that in the upgrade menu, there will be “Man.” –sign instead of “Done.” –sign atbeginning of name of the manually executed step.

Note!Once, user enters from main menu to upgrade menu, only way to get back to the main menu is to restartwhole macro.

3.2.2 Communication

The macro communicates with user by using the HIT Pop-up windows.

Asking the user to give information (e.g. paths, file names, etc.) & other user selections. Error situations Manual execution steps (i.e. when macro expects user to do some actions manually (e.g. copy some

files, install new HW /cabling etc.) Macro completion

Page 9: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

9 (270)

3.2.2.1 Log filesThe upgrade macro provides different log files, from where the user can verify the executed steps in macro andthe success of the different steps & commands executed in the macro. There are three different kind ofinformation / log files:

Log file from HIT Response window (<BSC_C-NUMBER>.log)o This log contains all the information of the macro execution (each MML command and the

whole output of the macro execution)o User can accept the default log-file name or specify a new one. Macro gives following pop-up

window for selection:

Macro writes separate log files for following steps:o Configuration printout (PRE)o Firmwareo Plug-in unit software upgradeo Safecopyo Transfer software to BSCo Configuration printout (PRE)

The same information can be found from both from a “main” log file and from these specified smaller logfiles.

o Log file from HIT Message window (Messages.log) The contents of the message window are saved after macro execution. Information about errors in macro execution

o “Log print” of HIT (TimeTable.log) This is a shorter description of the execution of the macro,and the log contains information about:

Starting an execution step in macro Execution status (Done). Completion of execution step in macro

If macro execution is stopped for some reason, the log files still remain in the folder the user has specified. Whenmacro execution is started again, the log writing is continued from the end of existing log files. All previouslywritten log information remains intact and nothing is overwritten.

Page 10: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

10 (270)

4 INTRODUCTION

The BSC implementation for ETP/ETP-A in BSC3i 1000/2000,Upgraded Flexi BSC procedure consists of thefollowing tasks:

Fallback copying of the current software BSC configuration printout (pre-check) Licence installation and feature activation BSC implementation for ETPE in case of transmission/line redundancy or HW redundancy BSC implementation for ETPT in case of transmission/line redundancy or HW redundancy BSC implementation for ETPA in case of Pool redundancy MCMU diagnostic Actions after upgrade and post conditions

o BSS Integrationo BSC configuration printout (post-check)

Fallback copying, BSC configuration printout tasks can be executed during daytime.

Actual upgrade is recommended to be executed during night-time. This procedure can be done for BSC3i1000/2000 Upgraded flexi BSC

In case when old configuration needs to be removed, the traffic must be moved, interface(s) removed becausethe plug-in unit needs to be deleted from equipment database. After successful upgrade and interfaces has beencreated back, the traffic can be moved back.

Note: The ETPLAN configuration will affect BSCs IP related connectivity and existing traffic in Gb over IP, Sigtran,DFCA.

The estimated time for HW upgrade depends on the configuration of the BSC.

The upgrade cannot be executed with traffic and traffic needs to be re-hosted. During upgrade effected unit(s) willbe blocked and state changed to TE-EX or SE-NH.

There is a choice of several options how the GTIC and ETC cartridges has been equipped before upgrade. Thechoices depend on the PIU types and configurations, like following:

use ETP (either for ETPE or ETPT) plug-in unit with line or hardware redundancy. use ETPA Plug-in unit with Pool redundancy.

Background Picture below describes the functioning of ETP plugin units:

Page 11: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

11 (270)

Packet Abis and AoIP implementations are needed in BSC3i. These features require new ETP PIUs. In practisethe HW will be a couple of ETP variants (e.g. ETP and ETP-A), because of the variety of requirements concerninginterfaces and functions. Packet Abis makes possible to use a packet switched based transmission of signalingand traffic (payload) between BTS and BSC.

This allows cellular network operators to migrate from traditional static TDM to PSN, and the low-cost transport ofIP and Ethernet, in a more efficient and cost effective way than with the already available solution adopting PWE3CESoPSN.

The concept is anyway valid regardless of the underlying Layer 1 solution being TDM based or Ethernet based.As a matter of fact, most of the gains provided by Packet Abis will also be capitalized in case legacy TDMnetworks have still to be supported (e.g. smooth migration path); especially the bandwidth saving achieved byonly transferring packets that contain data, compared with the previous technology that required empty packets tomaintain a constant bit rate.

ETP terminates Packet Abis in the BSC

AoIP provides A-interface u-plane and c-plane connections between BSS and CN over IP. SIGTRAN signalling isused for the c-plane. RTP payload formats for different speech codec’s and CS data/fax are used in the u-plane.A over IP is standardized in 3GPP.

There are two architecture options: The Transcoder function is located in the BSS (that is, the standard GSM architecture). The Transcoder

is the A over IP termination point. The Transcoder function is located in the Core Network (that is, the 3G network architecture). The BSC

is the A over IP termination point. At the same time, the BSC hides the mobility from the Core Network

In both cases the ETP terminates the A over IP u-plane.

PCU2-D

BSC

IP-BTSPacket Abisover TDM

(STM-1/OC-3)

GSWB

A over IPTC in MGW

TCSM3i

MGW

A over IPTC in BSS

IP-BTS

Packet Abisover Ethernet

ETTCSM2i,TCSM3ior MGW

TDMAter

ET

TDMAter

MGWESB24s

ETBTSDynamic Abis

PCU2-E* )

*) PCU2-E uses internalLAN for ETP

connectivity.

SET

SET

TCSM3i

MGWA over IPTC in BSS

BCSUsm/c planeto ETPs

Packet-switchednetwork

Packet-switchednetwork

Sn+pair

Sn+group

SBMUX

TR3sETPT

ETPE

ETP

ETPA

ETP-A

ETS2

STMUETP

ETPTETPE1/

T1

GigE

GigE

GigE

GigE

ETP

Sn+pair

Sn+pair

Sn+pair

ETPC

ETP-A

Sn+pair

ETPC

ETP-A

Sn+pair

Page 12: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

12 (270)

5 PRE-REQUIREMENTS

5.1 Pre-requirements & Actions needed prior upgrade

The procedure can be implemented for S16 software release onwards. It is recommended to install all availablechange deliveries prior to the upgrade.

Note!1. In case of BSC 3i 1000/2000 BCSU memory should be increased from 512 MB to 1GB if PABIS

feature is in use. For this refer Firmware and memory upgrade procedure document.2. L3 configuration in BSC is mandatory when ETPA,ETPE and/or ETPT are used.3.

SW licence and licence for L3 functionality for SWU unit is needed to be installed before actual upgrade can bestarted.

The following existing topologies should be active before starting upgrade.1. Upgraded Flexi BSC – T42. BSC 3i 1000/2000 - T6

Following configurations should be ready before starting upgrade to minimise downtime.1. IP Address Plan.2. SWU configurations from SWU-0 to SWU-7(for BSC 3i 1000/2000 will have SWU-8 and SWU-9). Which

includes Vlan, MSTP, OSPF/Static route; VRRP and interface configurations to equip ETPs as well asother IP based applications.

3. Site Switch configuration.4. All required upgrade cable kits.

IMPORTANT!Re-direct traffic from STMU/ETIP/ET16 cards in GTIC and ETC cat ridges before actual upgrade. Each ETPunit must be handled case by case and PCM areas which are affected during upgrade may vary. In caseupgrade causes disturbances to some other unit, the traffic needs to be re-directed, interfaces removedand unit needs to be deleted (PCM areas released to new ETP unit usage) from hardware database beforenew configuration is created.

BSS Split tool offers automated process to support BSC renewal. This is extremely useful, when older BSC(s) aremodernised to BSC3i(s). This process includes the automation of labor-intensive re-hosting of BTS to new BSC(s)including data and parameter updates to name a few. The downtime of operational BTS(s) is this way minimisedduring re-homing. If re-homing speed is the key driver, more than 100 sites can be moved to the new BSC duringone night by using .XML files for data transfer between the BSC(s) assisted by CM tools (CM Plan Manager, CMEditor and CM Analyser). Further information about BSS Split tools is available from Nokia OSS / Net Actrepresentatives.

5.2 Restrictions

During upgrade, the unit will be blocked, meaning that the interfaces which controlling unit is upgraded will beaffected. Macro informs user about affected PCM areas (and units handling that area) which are needed to bedeleted. After the upgrade has been finished successfully for one ETP unit the traffic can be re-directed back.

5.3 Needed documentation

To perform the upgrade successfully, the following documentation is required: BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSC (this document). L3 BSC IP Site Connectivity upgrade Plug-in unit software upgrade procedure Creating and managing BSC hardware (NED) Cabling Instructions for BSC3i (NED)

Page 13: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

13 (270)

Equipment list for BSC3i (NED) Pre-Processor Program Information Fallback copying instructions of DX200 BSC for BSC (NED) Technical Support Note: Minimum HW Requirements for BSC S1xx Release’ HIT User’s manual BSC Site IP Connectivity Guidelines and BSC Site IP Configuration Examples (NED documents). Firmware change and memory upgrade document

5.4 Needed equipment

To perform the upgrade successfully, the following HW are required: PC with installed HIT and upgrading macros Upgrade Set for upgrading transmission redundancy to HW redundancy for ETP plug in units in BSC

installation . Set required to implement either transmission redundancy or HW redundancy for ETP plug in units in

BSC installation for the first time.Note: ETP card is used as ETPE ( Packet Abis over ETH) and ETPT (Packet Abis over ETH)

Needed amount of ETP/ETP-A plug in units.Note: Interchangeability E of ETS2 unit brings support for Packet Abis over TDM- functionality.

5.5 HIT and upgrade macros

5.5.1 System requirements for HIT

HIT 3.4-0 swup is designed to operate on Windows and Linux.The HIT installation requires approximately 20MB disk space, of which the documentation occupies approximately5MB.

5.5.2 Installing HIT

It is necessary to go through this section only if the HIT release 3.4-0 swup has not been installed. If the softwarehas already been installed, proceed to the next section: Installing HIT upgrading macros.

HIT release 3.4-0 swup is delivered in Release Binder found from NOLS (Nokia Online Services). The installationof the software is done by executing the SETUP.EXE -program and following the instructions of the installationprogram.

5.5.3 Installing HIT upgrading macros

After the HIT program has been installed, it is necessary to install the upgrading macros. The upgrading macrosare included in the SW Release Binder which can be found from NOLS (Nokia Online Services). Release bindercontains all the macros used in different upgrades related to the SW Release.

To install the macros into PC, specify the folder to which the macros will be installed, press Unzip and the macroswill be installed.This zipped executable file includes the whole upgrade macro and the needed directory structure. The only userexecutable file, “UPGMAIN.HIT”, is extracted to root directory of macro folder HIT settings

5.5.4 HIT settings

Page 14: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

14 (270)

Before running HIT, it is recommended that the 'use of FIFO buffers' be turned off from the used communicationsport. This needs to be done, because some PCs communications port handling is unreliable with this settingactive.It is recommended that you contact your local PC support for instructions on how to turn off the use of FIFObuffers.If you are familiar with the settings of the PC, here's an example of how to turn the use of FIFO buffers off. InWindows 2000, the use of FIFO buffers is turned off in the following way:

1. Start Control Panel

2. From Control Panel select System

3. In the System Properties –dialog select Hardware/Device Manager

4. In Device Manager select desired communications port (usually COM1) and double-click it

5. In Communications Port (COMx) Properties –dialog select Port Settings

6. In Port Settings select Advanced

7. In Advanced Port Settings –dialog deactivate the 'Use FIFO buffers' and press OK

8. Close all the opened dialogs by pressing OK

When opening the HIT program the first time, remember to check/create the used device (ref. Hitguide.doc). It isrecommended to use the network element name for the devices.

5.5.5 Connection settings

When opening the HIT program the first time, remember to check/create the used devices (ref. Hitguide.doc).When the macro is started, the available devices are listed to select device to be connected.

Following connection types are supported: Local connection (COM)

Telnet

SSH

Via Netact (SSH)

Note: in S16 level onwards , via Netact (SSH) is only allowed.

5.5.5.1 Connection settings for Windows5.5.5.1.1 Configuration example for creating Telnet / SSH / NetAct connection

Select Device > Set Configuration… from menu.Following window appears

Page 15: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

15 (270)

Select New …

Give name for connection and IP address of OMU or NetAct server.Note!“DX_TELNET” is selected for telnet connection and “SSH” is selected for SSH connection in“Type/Protocol:” field. Default port for telnet is 23 and for SSH is 22.

Page 16: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

16 (270)

In case of Telnet or SSH connection option, select Login,Q/A sheet and define the username and password ofBSC MML session.

Note!In case of NetAct via SSH connection option, select Login sheet and define the username and password ofNetAct communication server and BSC MML session.

Page 17: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

17 (270)

Select Terminal sheet and define the MML log file.

If connection type is Telnet, press OK. In SSH connection, define also settings of SSH sheet. Define security level to medium or low level.

Page 18: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

18 (270)

After defining SSH related parameters, Press OK.

5.5.5.1.2 Configuration example for creating COM connection

Select Device > Set Configuration… from menu.Following window appears

Page 19: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

19 (270)

Note! “COM connection” is selected

Select “Login,Q/A” sheet and define the username and password of BSC MML session.

Page 20: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

20 (270)

Select Terminal sheet and define the MML log file.

Press OK.

Page 21: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

21 (270)

5.5.5.2 Connection settings for Linux5.5.5.2.1 Configuration example for creating Telnet / SSH / NetAct connection

Select Edit> Devices > … from menuFollowing window appears

Select New …

Give name for connection and IP address of OMU or Net Act server.

Note! “DX_TELNET” is selected for telnet connection and “SSH” is selected for SSH connection in“Type/Protocol:” field. Default port for telnet is 23 and for SSH is 22.

Page 22: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

22 (270)

In case of Telnet or SSH connection option, select Login,Q/A sheet and define the username and password ofBSC MML session.

Page 23: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

23 (270)

In case of NetAct via SSH connection option, select Login sheet and define the username and password ofNetAct communication server and BSC MML session.

Select Terminal sheet and define the MML log file.

If connection type is Telnet, press OK.

In SSH connection, define also settings of SSH sheet. Define security level to medium or low level.

Page 24: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

24 (270)

After defining SSH related parameters, Press OK.

5.5.5.2.2 Configuration example for creating COM connection

Select Edit> Devices > … from menuFollowing window appears

Page 25: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

25 (270)

Note! “COM connection” is selectedSelect “Login,Q/A” sheet and define the username and password of BSC MML session.

Select Terminal sheet and define the MML log file.

Press OK.

Page 26: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

26 (270)

5.5.6 Starting the HIT application / macro executionFirst of all, close List and Macro windows, as those are not needed. In Response window all MML commands areprinted out. It is recommended to keep Messages window as big as possible to able to follow up the macroexecution. The important information is printed out to the messages window.

Open file UPGMAIN.HIT from the location it was extracted and press Green Arrow to start the execution.

At the beginning, the main menu is shown and macro prompts user to choose which upgrade to execute. Clicking“CANCEL” in main menu aborts the macro execution.

Page 27: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

27 (270)

The macro informs user about the chosen procedure with following pop-up window:

Select ini file from the list.

Select target network element from the list.

Note!If NetAct connection has been chosen, choose the correct device which contains IP address definition toNetAct server.

Page 28: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

28 (270)

User may choose the location where the macro log files should be saved.

Also, user can define whether to use default log file name or define own.

Page 29: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

29 (270)

The status of the current BSC software package is checked. Note that the current software package must be withstatus BU before the actual upgrade can be started. The software status is to be checked with command:

ZWQO:RUN;

Check from the output that all the computer units which are currently in use are running on correct softwarepackage with the status BU. If the software package status is FB or NW, find out the cause for the setting.

If the status of the package is something else than BU, macro gives following pop-up window:

The status can be changed to BU with command:

ZWSC:STAT=NW:STAT=BU;

The active and blocked alarms (DX200 and BTS alarms) can be printed out with following commands:

ZAHO;ZABO;ZEOL;ZEOE;

Alarm printings can be skipped and macro asks user about the wanted action with following pop-up:

Page 30: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

30 (270)

Some environment information (status) is checked with following commands:ZQRI;ZIWQ:,OMU:WS=0,;ZDCD;ZUSI:ALL;ZWTI:P:OMU;ZUSI:BCSU;ZWTI:P:GSW,0;ZYE?

This information is gathered for BSC type analysis.

IMPORTANT!If MML session is needed during upgrade, open another MML connection than specified for the upgradeexecution. The same MML connection usage for interrogate or modification purposes may confuse the macroexecution.

The procedure dialog is divided in main chapters, which may also contain sub-chapters. Chapters and their sub-chapters correspond directly to the document. Select the chapter to run and press OK.Note!In order to complete upgrade successfully, the chapters and steps must be executed in ascending order.

Page 31: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

31 (270)

Select a step to run and press OK.

Page 32: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

32 (270)

6 FALLBACK COPYING OF THE CURRENT PACKAGE

A fallback copying of the running software package must be made before the upgrade.

A fallback copying from the old SW can be made by running macro step ‘Fallback copying of the currentpackage’.

Manually, the fallback copying can be made following the document: Fallback copying in BSC. The documentcan be found from NED.

Take running configurations from each SWU units seperately. Refer BSC Site IP Connectivity Guidelines for this.

Page 33: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

33 (270)

7 BSC CONFIGURATION PRINTOUT (PRE-CHECK)

The information about the BSC configurations and conditions are collected.

Precondition checking is recommended to do during the daytime before the actual upgrade will be started. Thechecking can be made by using the macro (UPGMAIN.HIT) or manually following the instructions from “BSCconfiguration printout”-document delivered in Release Binder.

For macro execution, choose the BSC configuration printout (pre) step in BSC implementation for ETP/ETP-Aprocedure. Follow then the macro execution according the BSC configuration printout –document.

Page 34: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

34 (270)

8 LICENCE INSTALLATION AND FEATURE ACTIVATION

SW licence is needed to be installed before actual upgrade can be started.

Macro checks the licence status and if licence is not installed properly the licence needs to be installed manuallyaccording to following instructions.

ZW7M: FEA=1533:ON; (PA over Ethernet)ZW7M: FEA=1535:ON; (PA over TDM)ZW7M: FEA=899:ON;( L-NWP – IUA)ZW7M: FEA=1234:ON;(L3 functionality for ESB switch)ZW7M: FEA=1753:CONF; (Ao IP, TC in MGW)

Note:- The feature 1753 should be put in CONF state.The feature can be turned ON once the installation ofETPA/ETP(A) and MSS/MGW configurations are completed.

Licence state can be printed with following command:ZW7I:FEA,FULL:FEA=1533;

Example:ZW7I:FEA,FULL:FEA=1533;FlexiBSC LION 12345 2010-09-13 14:50:48FEATURE INFORMATION:---------------------------------------------- FEATURE CODE:..............1533 FEATURE NAME:..............Packet Abis over IP/Ethernet FEATURE STATE:.............ON COMMAND EXECUTED

If licence state is OFF, change the state to ON with following command:ZW7M:FEA=1533:ON;

If licence is not installed, install the new licence file with the command:ZW7L:<licence_file_name>:ON;

Page 35: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

35 (270)

9 ETPLAN CONFIGURATION

This step introduces how to install SWU-6 and SWU-7 if not installed.

Install ESB24-D cards to the LANU-0 and LANU-1 cartridges to trackfor the following BSCs

BSC3i1000/2000 upgraded Flexi BSC

Install ESB24-D cards to LANU-0 and LANU-1:

BSC 3i 1000/2000

SWU indexCartridgeposition

Unit Cartridge/ Slots

6 1A5-0 LANU-0 57 1A5-2 LANU-1 5

Note: The traffic will be impacted during ESB configuration and cabling changes. IP plan for each SWUunits should be ready before proceeding next step. All SWU units needs to be configured when makingETPLAN cabling changes.

Following applications will not be available during upgrade. Please plan the traffic accordingly. LDI Sigtran GBoverIP BBI(DFCA) Lb VNP OSI(Q3) Telnet & FTP

Traffic will be resumed after completion of chapter 9.This activity will take approximately 6 hours tocomplete.

The following topologies are required for each BSC type.1. Initial BSC 3i 1000/2000 - T6 to T10 or T11 topology2. Upgraded flexi BSC – T4 to T8 topology

Note:Make sure that the SWUs are updated with latest software. Refer Appendix 4 for more details.

Also restore automatic configuration download settings if software upgrade is done for ESB cards manually. Donot do “restore factory defaults” when doing new configuration to ESB cards manually. This again will disable thealready enabled L3 license on the ESBs. If you wish to start doing new configurations by doing “restore factorydefaults” first, then you need to enable the L3 license.

9.1 Make SWU units to passive state

ZW6E:SWU,0:P;ZW6E:SWU,1:P;ZW6E:SWU,2:P;ZW6E:SWU,3:P;ZW6E:SWU,4:P;ZW6E:SWU,5:P;

Page 36: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

36 (270)

9.2 Make SWU units to SE-NH state

ZUSC:SWU,<unit index>:TE;ZUSC:SWU,<unit index>:SE;ZUSC:SWU,<unit index>:SE;

9.3 Cabling changes

Mark outgoing uplink cables in top of CPRJ45-A and take those out from connectors. Install needed cables (management, redundant etc) to new ESB24-D cards.

9.3.1 For initial BSC 3i 1000/2000

Note: For T10 topology we need SFPCS (SFPCS P02033 (FCFL-8521-3) module to add BSCC_4425-4428cables to ESB24-D, else for T11 topology we need SFPF2L modules to add BSCC_4435—4438.

9.3.1.1 For BSC 3i 1000 ( 1 cabinet)

Remove following cables.

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteAlternative 1 (Topology T10 optical uplinks are in use at panel on cabinets roof)

BSCC_821 LANU 0 5.0F02.ETH25

CPRJ45-A

T 0.4B00

CNI038 LAN Uplink

BSCC_822 LANU 1 5.2F02.ETH25

CPRJ45-A

T 0.4B08

CNI039 LAN Uplink

BSCC_823 LANU 0 5.0F03.ETH25

CPRJ45-A

T 0.4B01

CNI038 LAN Uplink

BSCC_824 LANU 1 5.2F03.ETH25

CPRJ45-A

T 0.4B09

CNI039 LAN Uplink

Alternative 2 (Topology T11 electrical uplinks are in use at panel on cabinets roof)

BSCC_815 LANU 0 5.0F02.ETH23

CPRJ45-A

T 0.4B04

CLCS038 LAN Uplink

BSCC_816 LANU 1 5.2F02.ETH23

CPRJ45-A

T 0.4B12

CLCS039 LAN Uplink

BSCC_817 LANU 0 5.0F03.ETH23

CPRJ45-A

T 0.4B05

CLCS038 LAN Uplink

BSCC_818 LANU 1 5.2F03.ETH23

CPRJ45-A

T 0.4B13

CLCS039 LAN Uplink

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteBSCC_420 LANU 0 5.0B

02.1ALANU 0 5.0B

03.1ACHES008 LAN

BSCC_422 LANU 1 5.2B02.1A

LANU 1 5.2B03.1A

CHES008 LAN

9.3.1.1.1 Add new configurations to ESB cards manually.Refer BSC Site IP Connectivity Guidelines andBSC Site IP Configuration Examples document for this.

Page 37: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

37 (270)

Add following redundancy and ETPLAN uplink cables.

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteBSCC_4420 LANU 0 5.0B

05.2RLANU 1 5.2B

05.2RCHES006 Redund.

BSCC_4421 LANU 0 5.0B05.2T

LANU 1 5.2B05.2T

CHES006 Redund.

BSCC_4422 LANU 0 5.0B05.2V

LANU 1 5.2B05.2V

CHES006 Redund.

BSCC_4423 LANU 0 5.0B05.2X

LANU 1 5.2B05.2X

CHES006 Redund.

Alternative 1 (Topology T10 optical uplinks are in use at panel on cabinets roof)BSCC_4425 LANU 0 5.0F

05.ETH1LANU 0 5.0F 02

ETH25CNIX006 ETPLAN

upl.BSCC_4426 LANU 0 5.0F

05.ETH2LANU 0 5.0F 03

ETH25CNIX006 ETPLAN

upl.BSCC_4427 LANU 1 5.2F

05.ETH1LANU 1 5.2F 02

ETH25CNIX006 ETPLAN

upl.

BSCC_4428 LANU 1 5.2F05.ETH2

LANU 1 5.2F 03ETH25

CNIX006 ETPLANupl.

Alternative 2 (Topology T11 electrical uplinks are in use at panel on cabinets roof)BSCC_4435 LANU 0 5.0F

05.ETH1LANU 0 5.0F 02

ETH23CLC006 ETPLAN

upl.BSCC_4436 LANU 0 5.0F

05.ETH2LANU 0 5.0F 03

ETH23 CLC006 ETPLAN

upl.BSCC_4437 LANU 1 5.2F

05.ETH1LANU 1 5.2F 02

ETH23 CLC006 ETPLAN

upl.BSCC_4438 LANU 1 5.2F

05.ETH2LANU 1 5.2F 03

ETH23 CLC006 ETPLAN

upl.

9.3.1.2 For BSC 3i 2000 (2 cabinet)

Remove following cables.

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteAlternative 1 (Topology T10 optical uplinks are in use at panel on cabinets roof)BSCC_821 LANU 0 5.0F

02.ETH25CPRJ45-A

T 0.4B00

CNI038 LAN Uplink

BSCC_822 LANU 1 5.2F02.ETH25

CPRJ45-A

T 0.4B08

CNI039 LAN Uplink

BSCC_823 LANU 0 5.0F03.ETH25

CPRJ45-A

T 0.4B01

CNI038 LAN Uplink

BSCC_824 LANU 1 5.2F03.ETH25

CPRJ45-A

T 0.4B09

CNI039 LAN Uplink

Alternative 2 (Topology T11 electrical uplinks are in use at panel on cabinets roof)BSCC_815 LANU 0 5.0F

02.ETH23CPRJ45-A

T 0.4B04

CLCS038 LAN Uplink

Page 38: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

38 (270)

BSCC_816 LANU 1 5.2F02.ETH23

CPRJ45-A

T 0.4B12

CLCS039 LAN Uplink

BSCC_817 LANU 0 5.0F03.ETH23

CPRJ45-A

T 0.4B05

CLCS038 LAN Uplink

BSCC_818 LANU 1 5.2F03.ETH23

CPRJ45-A

T 0.4B13

CLCS039 LAN Uplink

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteBSCC_420 LANU 0 5.0B

02.1ALANU 0 5.0B

03.1ACHES008 LAN

BSCC_422 LANU 1 5.2B02.1A

LANU 1 5.2B03.1A

CHES008 LAN

9.3.1.2.1 Add new configurations to ESB cards manually. Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Add following ETPLAN uplink and redundancy cables.

Equipping CABLE FROM CABLE TONo FU Position FU Position Type Use NoteBSCC_4420 LANU 0 5.0B

05.2RLANU 1 5.2B

05.2RCHES006 Redund.

BSCC_4421 LANU 0 5.0B05.2T

LANU 1 5.2B05.2T

CHES006 Redund.

BSCC_4422 LANU 0 5.0B05.2V

LANU 1 5.2B05.2V

CHES006 Redund.

BSCC_4423 LANU 0 5.0B05.2X

LANU 1 5.2B05.2X

CHES006 Redund.

Alternative 1 (Topology T10 optical uplinks are in use at panel on cabinets roof)BSCC_4425 LANU 0 5.0F

05.ETH1LANU 0 5.0F 02

ETH25CNIX006 ETPLAN

upl.BSCC_4426 LANU 0 5.0F

05.ETH2LANU 0 5.0F 03

ETH25CNIX006 ETPLAN

upl.BSCC_4427 LANU 1 5.2F

05.ETH1LANU 1 5.2F 02

ETH25CNIX006 ETPLAN

upl.BSCC_4428 LANU 1 5.2F

05.ETH2LANU 1 5.2F 03

ETH25CNIX006 ETPLAN

upl.Alternative 2 (Topology T11 electrical uplinks are in use at panel on cabinets roof)BSCC_4435 LANU 0 5.0F

05.ETH1LANU 0 5.0F 02

ETH23CLC006 ETPLAN

upl.BSCC_4436 LANU 0 5.0F

05.ETH2LANU 0 5.0F 03

ETH23 CLC006 ETPLAN

upl.BSCC_4437 LANU 1 5.2F

05.ETH1LANU 1 5.2F 02

ETH23 CLC006 ETPLAN

upl.BSCC_4438 LANU 1 5.2F

05.ETH2LANU 1 5.2F 03

ETH23 CLC006 ETPLAN

upl.

9.3.2 Upgraded flexi BSC-Upgrades from BSC3i 1000/2000(initial)

9.3.2.1 For Upgraded Flexi BSC (1 cabinet)

Remove following cables.

Page 39: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

39 (270)

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_1014 LANU0

1.8B04.2E

BCSU5

4.8B02.2D

CHG020 LAN Downlink

BSCC_1034 LANU1

1.10B04.2E

BCSU5

4.8B02.2S

CHG019 LAN Downlink

9.3.2.1.1 Add new configurations to ESB cards manually.Refer BSC Site IP Connectivity Guidelines andBSC Site IP Configuration Examples document for this.

Move and Reconnect following cables.Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_420 LANU 0 1.8B02.1A

1.8B03.1C

LANU 0 1.8B03.1A

1.8B05.2V

CHES008 LAN LDI

BSCC_422 LANU 1 1.10B02.1A

1.10B03.1A

LANU 1 1.10B03.1A

1.10B05.2T

CHES008 LAN LDI

BSCC_1160 LANU 0 1.8F03.ETH2

- LANU 0 1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink

BSCC_1161 LANU 1 1.10F03.ETH2

- LANU 1 1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink

BSCC_1164 LANU 0 1.8B03.1C

1.8B03.1E

LANU 1 1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_1165 LANU 0 1.8B04.1C

1.8B03.1G

LANU 1 1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

BSCC_1010 LANU 0 1.8B03.1E

1.8B04.2T

BCSU 3 4.0B02.2D

- CHG025 LAN Downlink

BSCC_1011 LANU 0 1.8B04.2V

1.8B04.2P

BCSU 3 4.0B02.2K

- CHF023 LAN Downlink

BSCC_1012 LANU 0 1.8B04.2P

1.8B04.2J

BCSU 4 4.4B02.2D

- CHG021 LAN Downlink

BSCC_1013 LANU 0 1.8B04.2L

1.8B04.2E

BCSU 4 4.4B02.2K

- CHF021 LAN Downlink

BSCC_1015 LANU 0 1.8B04.2A

1.8B04.1L

BCSU 5 4.8B02.2K

- CHF020 LAN Downlink

BSCC_1030 LANU 1 1.10B03.1E

1.10B04.2T

BCSU 3 4.0B02.2S

- CHG024 LAN Downlink

BSCC_1031 LANU 1 1.10B04.2V

1.10B04.2P

BCSU 3 4.0B02.2Y

- CHF022 LAN Downlink

BSCC_1032 LANU 1 1.10B04.2P

1.10B04.2J

BCSU 4 4.4B02.2S

- CHG020 LAN Downlink

BSCC_1033 LANU 1 1.10B04.2L

1.10B04.2E

BCSU 4 4.4B02.2Y

- CHF020 LAN Downlink

BSCC_1035 LANU 1 1.10B04.2A

1.10B04.1L

BCSU 5 4.8B02.2Y

- CHF019 LAN Downlink

BSCC_1042 LANU 0 1.8B04.1L

1.8B04.1E

BCSU 6 5.0B02.2D

- CHG028 LAN Downlink

BSCC_1043 LANU 0 1.8B04.1G

1.8B04.1A

BCSU 6 5.0B02.2K

- CHF028 LAN Downlink

Page 40: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

40 (270)

BSCC_1044 LANU 1 1.10B04.1L

1.10B04.1E

BCSU 6 5.0B02.2S

- CHG027 LAN Downlink

BSCC_1045 LANU 1 1.10B04.1G

1.10B04.1A

BCSU 6 5.0B02.2Y

- CHF027 LAN Downlink

Add following cables.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4420 LANU 0 1.8B05.2T

LANU 0 1.8B03.1A

CHES006 ETPLAN LDI

BSCC_4423 LANU 1 1.10B05.2V

LANU 1 1.10B03.1C

CHES006 ETPLAN LDI

BSCC_4470 LANU 0 1.8B02.1A

LANU 0 1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU 1 1.10B02.1A

LANU 1 1.10B05.1A

CHES008 LAN LDI

BSCC_4481 LANU 0 1.8F03.ETH24

LANU 0 1.8F04.ETH2

CNIX006 LAN LDI

BSCC_4483 LANU 1 1.10F03.ETH24

LANU 1 1.10F04.ETH2

CNIX006 LAN LDI

BSCC_4484 LANU 0 1.8F04.ETH23

LANU 1 1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU 0 1.8F04.ETH24

LANU 1 1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU 0 1.8F05.ETH1

LANU 1 1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU 0 1.8F05.ETH2

LANU 1 1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU 0 1.8F05.ETH23

LANU 1 1.10F05.ETH23

CNIX006 LAN Redund.

BSCC_4489 LANU 0 1.8F05.ETH24

LANU 1 1.10F05.ETH24

CNIX006 LAN Redund.

BSCC_4460 LANU 0 1.8B04.2A

BCSU5

4.8B02.2F

CHF020 LAN Downlink

BSCC_4461 LANU 0 1.8B04.1P

BCSU5

4.8B02.2D

CHE021 LAN Downlink

BSCC_4463 LANU 1 1.10B04.2A

BCSU5

4.8B02.2U

CHF019 LAN Downlink

BSCC_4464 LANU 1 1.10B04.1P

BCSU5

4.8B02.2S

CHE020 LAN Downlink

9.3.2.2 For Upgraded Flexi BSC (2 cabinet)

Remove following cables.

Equipping CABLE FROM CABLE TO

Page 41: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

41 (270)

No FU Position FU Position Type Use Note

BSCC_1014 LANU 0 1.8B04.2E

BCSU 5 4.8B02.2D

CHG020 LAN Downlink

BSCC_1034 LANU 1 1.10B04.2E

BCSU 5 4.8B02.2S

CHG019 LAN Downlink

9.3.2.2.1 Add new configurations to ESB cards manually.Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Move and reconnect following cables.

Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_420 LANU0

1.8B02.1A

1.8B03.1C

LANU0

1.8B03.1A

1.8B05.2V

CHES008 LAN LDI

BSCC_422 LANU1

1.10B02.1A

1.10B03.1A

LANU1

1.10B03.1A

1.10B05.2T

CHES008 LAN LDI

BSCC_1160 LANU0

1.8F03.ETH2

- LANU0

1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink

BSCC_1161 LANU1

1.10F03.ETH2

- LANU1

1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink

BSCC_1164 LANU0

1.8B03.1C

1.8B03.1E

LANU1

1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_1165 LANU0

1.8B04.1C

1.8B03.1G

LANU1

1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

BSCC_1010 LANU0

1.8B03.1E

1.8B04.2T

BCSU3

4.0B02.2D

- CHG025 LAN Downlink

BSCC_1011 LANU0

1.8B04.2V

1.8B04.2P

BCSU3

4.0B02.2K

- CHF023 LAN Downlink

BSCC_1012 LANU0

1.8B04.2P

1.8B04.2J

BCSU4

4.4B02.2D

- CHG021 LAN Downlink

BSCC_1013 LANU0

1.8B04.2L

1.8B04.2E

BCSU4

4.4B02.2K

- CHF021 LAN Downlink

BSCC_1015 LANU0

1.8B04.2A

1.8B04.1L

BCSU5

4.8B02.2K

- CHF020 LAN Downlink

BSCC_1030 LANU1

1.10B03.1E

1.10B04.2T

BCSU3

4.0B02.2S

- CHG024 LAN Downlink

BSCC_1031 LANU1

1.10B04.2V

1.10B04.2P

BCSU3

4.0B02.2Y

- CHF022 LAN Downlink

BSCC_1032 LANU1

1.10B04.2P

1.10B04.2J

BCSU4

4.4B02.2S

- CHG020 LAN Downlink

BSCC_1033 LANU1

1.10B04.2L

1.10B04.2E

BCSU4

4.4B02.2Y

- CHF020 LAN Downlink

BSCC_1035 LANU1

1.10B04.2A

1.10B04.1L

BCSU5

4.8B02.2Y

- CHF019 LAN Downlink

BSCC_1042 LANU0

1.8B04.1L

1.8B04.1E

BCSU6

5.0B02.2D

- CHG028 LAN Downlink

BSCC_1043 LANU0

1.8B04.1G

1.8B04.1A

BCSU6

5.0B02.2K

- CHF028 LAN Downlink

BSCC_1044 LANU1

1.10B04.1L

1.10B04.1E

BCSU6

5.0B02.2S

- CHG027 LAN Downlink

Page 42: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

42 (270)

BSCC_1045 LANU1

1.10B04.1G

1.10B04.1A

BCSU6

5.0B02.2Y

- CHF027 LAN Downlink

Add following cables

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4420 LANU0

1.8B05.2T

LANU0

1.8B03.1A

CHES006 ETPLAN LDI

BSCC_4423 LANU1

1.10B05.2V

LANU1

1.10B03.1C

CHES006 ETPLAN LDI

BSCC_4470 LANU0

1.8B02.1A

LANU0

1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU1

1.10B02.1A

LANU1

1.10B05.1A

CHES008 LAN LDI

BSCC_4481 LANU0

1.8F03.ETH24

LANU0

1.8F04.ETH2

CNIX006 LAN LDI

BSCC_4483 LANU1

1.10F03.ETH24

LANU1

1.10F04.ETH2

CNIX006 LAN LDI

BSCC_4484 LANU0

1.8F04.ETH23

LANU1

1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU0

1.8F04.ETH24

LANU1

1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU0

1.8F05.ETH1

LANU1

1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU0

1.8F05.ETH2

LANU1

1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU0

1.8F05.ETH23

LANU1

1.10F05.ETH23

CNIX006 LAN Redund.

BSCC_4489 LANU0

1.8F05.ETH24

LANU1

1.10F05.ETH24

CNIX006 LAN Redund.

BSCC_4460 LANU0

1.8B04.2A

BCSU5

4.8B02.2F

CHF020 LAN Downlink

BSCC_4461 LANU0

1.8B04.1P

BCSU5

4.8B02.2D

CHE021 LAN Downlink

BSCC_4463 LANU1

1.10B04.2A

BCSU5

4.8B02.2U

CHF019 LAN Downlink

BSCC_4464 LANU1

1.10B04.1P

BCSU5

4.8B02.2S

CHE020 LAN Downlink

9.3.3 Upgraded flexi BSC-Upgrades from BSC3i 1000/2000( 660 initial)

9.3.3.1 For Upgraded Flexi BSC (1 cabinet)

Page 43: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

43 (270)

9.3.3.1.1 Add new configurations to ESB cards manually. Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Move and reconnect the following cables.

Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_420 LANU 0 1.8B02.1A

1.8B03.1C

LANU 0 1.8B03.1A

1.8B05.2V

CHES008 LAN Uplink&LDI

BSCC_422 LANU 1 1.10B02.1A

1.10B03.1A

LANU 1 1.10B03.1A

1.10B05.2T

CHES008 LAN Uplink&LDI

BSCC_2041 LANU 0 1.8B04.1G

1.8B04.1A

BCSU6

5.0B06.1G

- CHES028 LAN Downlink

BSCC_2040 LANU 0 1.8B04.1J

1.8B04.1C

BCSU6

5.0B07.1G

- CHES028 LAN Downlink

BSCC_2039 LANU 0 1.8B04.1L

1.8B04.1E

BCSU6

5.0B03.1G

- CHES028 LAN Downlink

BSCC_2038 LANU 0 1.8B04.1N

1.8B04.1G

BCSU6

5.0B04.1G

- CHES028 LAN Downlink

BSCC_2037 LANU 0 1.8B04.1P

1.8B04.1J

BCSU6

5.0B05.1G

- CHES028 LAN Downlink

BSCC_2036 LANU 0 1.8B04.2A

1.8B04.1L

BCSU5

4.8B06.1G

- CHES020 LAN Downlink

BSCC_2035 LANU 0 1.8B04.2C

1.8B04.1N

BCSU5

4.8B07.1G

- CHES020 LAN Downlink

BSCC_2034 LANU 0 1.8B04.2E

1.8B04.1P

BCSU5

4.8B03.1G

- CHES020 LAN Downlink

BSCC_2033 LANU 0 1.8B04.2G

1.8B04.2A

BCSU5

4.8B04.1G

- CHES020 LAN Downlink

BSCC_2032 LANU 0 1.8B04.2J

1.8B04.2C

BCSU5

4.8B05.1G

- CHES020 LAN Downlink

BSCC_2031 LANU 0 1.8B04.2L

1.8B04.2E

BCSU4

4.4B06.1G

- CHES021 LAN Downlink

BSCC_2030 LANU 0 1.8B04.2N

1.8B04.2G

BCSU4

4.4B07.1G

- CHES021 LAN Downlink

BSCC_2029 LANU 0 1.8B04.2P

1.8B04.2J

BCSU4

4.4B03.1G

- CHES022 LAN Downlink

BSCC_2028 LANU 0 1.8B04.2R

1.8B04.2L

BCSU4

4.4B04.1G

- CHES022 LAN Downlink

BSCC_2027 LANU 0 1.8B04.2T

1.8B04.2N

BCSU4

4.4B05.1G

- CHES022 LAN Downlink

BSCC_2026 LANU 0 1.8B04.2V

1.8B04.2P

BCSU3

4.0B06.1G

- CHES024 LAN Downlink

BSCC_2025 LANU 0 1.8B04.2X

1.8B04.2R

BCSU3

4.0B07.1G

- CHES024 LAN Downlink

BSCC_2024 LANU 0 1.8B03.1E

1.8B04.2T

BCSU3

4.0B03.1G

- CHES024 LAN Downlink

BSCC_2023 LANU 0 1.8B03.1G

1.8B04.2V

BCSU3

4.0B04.1G

- CHES024 LAN Downlink

BSCC_2022 LANU 0 1.8B03.1J

1.8B04.2X

BCSU3

4.0B05.1G

- CHES024 LAN Downlink

Page 44: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

44 (270)

BSCC_2081 LANU 1 1.10B04.1G

1.10B04.1A

BCSU6

5.0B06.1J

- CHES027 LAN Downlink

BSCC_2080 LANU 1 1.10B04.1J

1.10B04.1C

BCSU6

5.0B07.1J

- CHES027 LAN Downlink

BSCC_2079 LANU 1 1.10B04.1L

1.10B04.1E

BCSU6

5.0B03.1J

- CHES027 LAN Downlink

BSCC_2078 LANU 1 1.10B04.1N

1.10B04.1G

BCSU6

5.0B04.1J

- CHES027 LAN Downlink

BSCC_2077 LANU 1 1.10B04.1P

1.10B04.1J

BCSU6

5.0B05.1J

- CHES027 LAN Downlink

BSCC_2076 LANU 1 1.10B04.2A

1.10B04.1L

BCSU5

4.8B06.1J

- CHES019 LAN Downlink

BSCC_2075 LANU 1 1.10B04.2C

1.10B04.1N

BCSU5

4.8B07.1J

- CHES019 LAN Downlink

BSCC_2074 LANU 1 1.10B04.2E

1.10B04.1P

BCSU5

4.8B03.1J

- CHES019 LAN Downlink

BSCC_2073 LANU 1 1.10B04.2G

1.10B04.2A

BCSU5

4.8B04.1J

- CHES019 LAN Downlink

BSCC_2072 LANU 1 1.10B04.2J

1.10B04.2C

BCSU5

4.8B05.1J

- CHES019 LAN Downlink

BSCC_2071 LANU 1 1.10B04.2L

1.10B04.2E

BCSU4

4.4B06.1J

- CHES020 LAN Downlink

BSCC_2070 LANU 1 1.10B04.2N

1.10B04.2G

BCSU4

4.4B07.1J

- CHES020 LAN Downlink

BSCC_2069 LANU 1 1.10B04.2P

1.10B04.2J

BCSU4

4.4B03.1J

- CHES021 LAN Downlink

BSCC_2068 LANU 1 1.10B04.2R

1.10B04.2L

BCSU4

4.4B04.1J

- CHES021 LAN Downlink

BSCC_2067 LANU 1 1.10B04.2T

1.10B04.2N

BCSU4

4.4B05.1J

- CHES021 LAN Downlink

BSCC_2066 LANU 1 1.10B04.2V

1.10B04.2P

BCSU3

4.0B06.1J

- CHES023 LAN Downlink

BSCC_2065 LANU 1 1.10B04.2X

1.10B04.2R

BCSU3

4.0B07.1J

- CHES023 LAN Downlink

BSCC_2064 LANU 1 1.10B03.1E

1.10B04.2T

BCSU3

4.0B03.1J

- CHES023 LAN Downlink

BSCC_2063 LANU 1 1.10B03.1G

1.10B04.2V

BCSU3

4.0B04.1J

- CHES023 LAN Downlink

BSCC_2062 LANU 1 1.10B03.1J

1.10B04.2X

BCSU3

4.0B05.1J

- CHES023 LAN Downlink

BSCC_2095 LANU 0 1.8F03.ETH2

- LANU 0 1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_2096 LANU 1 1.10F03.ETH2

- LANU 1 1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_2193 LANU 0 1.8B03.1C

1.8B03.1E

LANU 1 1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_2194 LANU 0 1.8B04.1C

1.8B03.1G

LANU 1 1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

Add following cables.

Equipping CABLE FROM CABLE TO

Page 45: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

45 (270)

No FU Position FU Position Type Use Note

BSCC_4420 LANU0

1.8B05.2T

LANU0

1.8B03.1A

CHES006 ETPLAN Uplink&LDI

BSCC_4423 LANU1

1.10B05.2V

LANU1

1.10B03.1C

CHES006 ETPLAN Uplink&LDI

BSCC_4470 LANU0

1.8B02.1A

LANU0

1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU1

1.10B02.1A

LANU1

1.10B05.1A

CHES008 LAN LDI

BSCC_3182 LANU0

1.8B02.1E

LANU1

1.10B02.1E

CHES008 LAN Redund.1)

BSCC_4481 LANU0

1.8F03.ETH24

LANU0

1.8F04.ETH2

CNIX006 LAN LDI

BSCC_4483 LANU1

1.10F03.ETH24

LANU1

1.10F04.ETH2

CNIX006 LAN LDI

BSCC_4484 LANU0

1.8F04.ETH23

LANU1

1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU0

1.8F04.ETH24

LANU1

1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU0

1.8F05.ETH1

LANU1

1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU0

1.8F05.ETH2

LANU1

1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU0

1.8F05.ETH23

LANU1

1.10F05.ETH23

CNIX006 LAN Redund.

BSCC_4489 LANU0

1.8F05.ETH24

LANU1

1.10F05.ETH24

CNIX006 LAN Redund.

Notes:To be added only in case upgrade to FlexiBSC was performed with C110707 older than revision 08

9.3.3.2 For Upgraded Flexi BSC (2 cabinet)

9.3.3.2.1 Add new configurations to ESB cards manually. Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Move and reconnect the following cables.

Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_420 LANU 0 1.8B02.1A

1.8B03.1C

LANU 0 1.8B03.1A

1.8B05.2V

CHES008 LAN LDI

BSCC_422 LANU 1 1.10B02.1A

1.10B03.1A

LANU 1 1.10B03.1A

1.10B05.2T

CHES008 LAN LDI

BSCC_2041 LANU 0 1.8B04.1G

1.8B04.1A

BCSU6

5.0B06.1G

- CHES028 LAN Downlink

Page 46: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

46 (270)

BSCC_2040 LANU 0 1.8B04.1J

1.8B04.1C

BCSU6

5.0B07.1G

- CHES028 LAN Downlink

BSCC_2039 LANU 0 1.8B04.1L

1.8B04.1E

BCSU6

5.0B03.1G

- CHES028 LAN Downlink

BSCC_2038 LANU 0 1.8B04.1N

1.8B04.1G

BCSU6

5.0B04.1G

- CHES028 LAN Downlink

BSCC_2037 LANU 0 1.8B04.1P

1.8B04.1J

BCSU6

5.0B05.1G

- CHES028 LAN Downlink

BSCC_2036 LANU 0 1.8B04.2A

1.8B04.1L

BCSU5

4.8B06.1G

- CHES020 LAN Downlink

BSCC_2035 LANU 0 1.8B04.2C

1.8B04.1N

BCSU5

4.8B07.1G

- CHES020 LAN Downlink

BSCC_2034 LANU 0 1.8B04.2E

1.8B04.1P

BCSU5

4.8B03.1G

- CHES020 LAN Downlink

BSCC_2033 LANU 0 1.8B04.2G

1.8B04.2A

BCSU5

4.8B04.1G

- CHES020 LAN Downlink

BSCC_2032 LANU 0 1.8B04.2J

1.8B04.2C

BCSU5

4.8B05.1G

- CHES020 LAN Downlink

BSCC_2031 LANU 0 1.8B04.2L

1.8B04.2E

BCSU4

4.4B06.1G

- CHES021 LAN Downlink

BSCC_2030 LANU 0 1.8B04.2N

1.8B04.2G

BCSU4

4.4B07.1G

- CHES021 LAN Downlink

BSCC_2029 LANU 0 1.8B04.2P

1.8B04.2J

BCSU4

4.4B03.1G

- CHES022 LAN Downlink

BSCC_2028 LANU 0 1.8B04.2R

1.8B04.2L

BCSU4

4.4B04.1G

- CHES022 LAN Downlink

BSCC_2027 LANU 0 1.8B04.2T

1.8B04.2N

BCSU4

4.4B05.1G

- CHES022 LAN Downlink

BSCC_2026 LANU 0 1.8B04.2V

1.8B04.2P

BCSU3

4.0B06.1G

- CHES024 LAN Downlink

BSCC_2025 LANU 0 1.8B04.2X

1.8B04.2R

BCSU3

4.0B07.1G

- CHES024 LAN Downlink

BSCC_2024 LANU 0 1.8B03.1E

1.8B04.2T

BCSU3

4.0B03.1G

- CHES024 LAN Downlink

BSCC_2023 LANU 0 1.8B03.1G

1.8B04.2V

BCSU3

4.0B04.1G

- CHES024 LAN Downlink

BSCC_2022 LANU 0 1.8B03.1J

1.8B04.2X

BCSU3

4.0B05.1G

- CHES024 LAN Downlink

BSCC_2081 LANU 1 1.10B04.1G

1.10B04.1A

BCSU6

5.0B06.1J

CHES027 LAN Downlink

BSCC_2080 LANU 1 1.10B04.1J

1.10B04.1C

BCSU6

5.0B07.1J

CHES027 LAN Downlink

BSCC_2079 LANU 1 1.10B04.1L

1.10B04.1E

BCSU6

5.0B03.1J

CHES027 LAN Downlink

BSCC_2078 LANU 1 1.10B04.1N

1.10B04.1G

BCSU6

5.0B04.1J

CHES027 LAN Downlink

BSCC_2077 LANU 1 1.10B04.1P

1.10B04.1J

BCSU6

5.0B05.1J

CHES027 LAN Downlink

BSCC_2076 LANU 1 1.10B04.2A

1.10B04.1L

BCSU5

4.8B06.1J

CHES019 LAN Downlink

BSCC_2075 LANU 1 1.10B04.2C

1.10B04.1N

BCSU5

4.8B07.1J

CHES019 LAN Downlink

BSCC_2074 LANU 1 1.10B04.2E

1.10B04.1P

BCSU5

4.8B03.1J

CHES019 LAN Downlink

Page 47: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

47 (270)

BSCC_2073 LANU 1 1.10B04.2G

1.10B04.2A

BCSU5

4.8B04.1J

CHES019 LAN Downlink

BSCC_2072 LANU 1 1.10B04.2J

1.10B04.2C

BCSU5

4.8B05.1J

CHES019 LAN Downlink

BSCC_2071 LANU 1 1.10B04.2L

1.10B04.2E

BCSU4

4.4B06.1J

- CHES020 LAN Downlink

BSCC_2070 LANU 1 1.10B04.2N

1.10B04.2G

BCSU4

4.4B07.1J

- CHES020 LAN Downlink

BSCC_2069 LANU 1 1.10B04.2P

1.10B04.2J

BCSU4

4.4B03.1J

- CHES021 LAN Downlink

BSCC_2068 LANU 1 1.10B04.2R

1.10B04.2L

BCSU4

4.4B04.1J

- CHES021 LAN Downlink

BSCC_2067 LANU 1 1.10B04.2T

1.10B04.2N

BCSU4

4.4B05.1J

- CHES021 LAN Downlink

BSCC_2066 LANU 1 1.10B04.2V

1.10B04.2P

BCSU3

4.0B06.1J

- CHES023 LAN Downlink

BSCC_2065 LANU 1 1.10B04.2X

1.10B04.2R

BCSU3

4.0B07.1J

- CHES023 LAN Downlink

BSCC_2064 LANU 1 1.10B03.1E

1.10B04.2T

BCSU3

4.0B03.1J

- CHES023 LAN Downlink

BSCC_2063 LANU 1 1.10B03.1G

1.10B04.2V

BCSU3

4.0B04.1J

- CHES023 LAN Downlink

BSCC_2062 LANU 1 1.10B03.1J

1.10B04.2X

BCSU3

4.0B05.1J

- CHES023 LAN Downlink

BSCC_2095 LANU 0 1.8F03.ETH2

- LANU 0 1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_2096 LANU 1 1.10F03.ETH2

- LANU 1 1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_2193 LANU 0 1.8B03.1C

1.8B03.1E

LANU 1 1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_2194 LANU 0 1.8B04.1C

1.8B03.1G

LANU 1 1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

Add following cables.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4420 LANU0

1.8B05.2T

LANU0

1.8B03.1A

CHES006 ETPLAN Uplink&LDI.

BSCC_4423 LANU1

1.10B05.2V

LANU1

1.10B03.1C

CHES006 ETPLAN Uplink&LDI.

BSCC_4470 LANU0

1.8B02.1A

LANU0

1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU1

1.10B02.1A

LANU1

1.10B05.1A

CHES008 LAN LDI

BSCC_3182 LANU0

1.8B02.1E

LANU1

1.10B02.1E

CHES008 LAN Redund.1)

BSCC_4481 LANU0

1.8F03.ETH24

LANU0

1.8F04.ETH2

CNIX006 LAN Uplink&LDI

BSCC_4483 LANU1

1.10F03.ETH24

LANU1

1.10F04.ETH2

CNIX006 LAN Uplink&LDI

Page 48: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

48 (270)

BSCC_4484 LANU0

1.8F04.ETH23

LANU1

1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU0

1.8F04.ETH24

LANU1

1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU0

1.8F05.ETH1

LANU1

1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU0

1.8F05.ETH2

LANU1

1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU0

1.8F05.ETH23

LANU1

1.10F05.ETH23

CNIX006 LAN Redund.

BSCC_4489 LANU0

1.8F05.ETH24

LANU1

1.10F05.ETH24

CNIX006 LAN Redund.

Notes:To be added only in case upgrade to FlexiBSC was performed with C110707 older than revision 08.

9.3.4 Upgraded flexi BSC-Upgrades from BSC3i 660(initial)

9.3.4.1 For Upgraded Flexi BSC (1 cabinet)

9.3.4.1.1 Add new configurations to ESB cards manually. Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Move and reconnect the following cables.

Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_3090 LANU0

1.8B04.2X

1.8B04.2R

BCSU3

4.0B07.1G

- CHES024 LAN Downlink

BSCC_3091 LANU0

1.8B04.2V

1.8B04.2P

BCSU3

4.0B06.1G

- CHES024 LAN Downlink

BSCC_3087 LANU0

1.8B03.1E

1.8B04.2T

BCSU3

4.0B03.1G

- CHES024 LAN Downlink

BSCC_3086 LANU0

1.8B03.1G

1.8B04.2V

BCSU3

4.0B04.1G

- CHES024 LAN Downlink

BSCC_3085 LANU0

1.8B03.1J

1.8B04.2X

BCSU3

4.0B05.1G

- CHES024 LAN Downlink

BSCC_3096 LANU0

1.8B04.2L

1.8B04.2E

BCSU4

4.4B06.1G

- CHES021 LAN Downlink

BSCC_3095 LANU0

1.8B04.2N

1.8B04.2G

BCSU4

4.4B07.1G

- CHES021 LAN Downlink

BSCC_3094 LANU0

1.8B04.2P

1.8B04.2J

BCSU4

4.4B03.1G

- CHES022 LAN Downlink

BSCC_3093 LANU0

1.8B04.2R

1.8B04.2L

BCSU4

4.4B04.1G

- CHES022 LAN Downlink

BSCC_3092 LANU0

1.8B04.2T

1.8B04.2N

BCSU4

4.4B05.1G

- CHES022 LAN Downlink

Page 49: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

49 (270)

BSCC_3106 LANU0

1.8B04.1G

1.8B04.1A

BCSU6

5.0B06.1G

- CHES028 LAN Downlink

BSCC_3105 LANU0

1.8B04.1J

1.8B04.1C

BCSU6

5.0B07.1G

- CHES028 LAN Downlink

BSCC_3104 LANU0

1.8B04.1L

1.8B04.1E

BCSU6

5.0B03.1G

- CHES028 LAN Downlink

BSCC_3103 LANU0

1.8B04.1N

1.8B04.1G

BCSU6

5.0B04.1G

- CHES028 LAN Downlink

BSCC_3102 LANU0

1.8B04.1P

1.8B04.1J

BCSU6

5.0B05.1G

- CHES028 LAN Downlink

BSCC_3101 LANU0

1.8B04.2A

1.8B04.1L

BCSU5

4.8B06.1G

- CHES020 LAN Downlink

BSCC_3100 LANU0

1.8B04.2C

1.8B04.1N

BCSU5

4.8B07.1G

- CHES020 LAN Downlink

BSCC_3099 LANU0

1.8B04.2E

1.8B04.1P

BCSU5

4.8B03.1G

- CHES020 LAN Downlink

BSCC_3098 LANU0

1.8B04.2G

1.8B04.2A

BCSU5

4.8B04.1G

- CHES020 LAN Downlink

BSCC_3097 LANU0

1.8B04.2J

1.8B04.2C

BCSU5

4.8B05.1G

- CHES020 LAN Downlink

BSCC_3151 LANU1

1.10B04.2V

1.10B04.2P

BCSU3

4.0B06.1J

- CHES023 LAN Downlink

BSCC_3150 LANU1

1.10B04.2X

1.10B04.2R

BCSU3

4.0B07.1J

- CHES023 LAN Downlink

BSCC_3147 LANU1

1.10B03.1E

1.10B04.2T

BCSU3

4.0B03.1J

- CHES023 LAN Downlink

BSCC_3146 LANU1

1.10B03.1G

1.10B04.2V

BCSU3

4.0B04.1J

- CHES023 LAN Downlink

BSCC_3145 LANU1

1.10B03.1J

1.10B04.2X

BCSU3

4.0B05.1J

- CHES023 LAN Downlink

BSCC_3166 LANU1

1.10B04.1G

1.10B04.1A

BCSU6

5.0B06.1J

- CHES027 LAN Downlink

BSCC_3165 LANU1

1.10B04.1J

1.10B04.1C

BCSU6

5.0B07.1J

- CHES027 LAN Downlink

BSCC_3164 LANU1

1.10B04.1L

1.10B04.1E

BCSU6

5.0B03.1J

- CHES027 LAN Downlink

BSCC_3163 LANU1

1.10B04.1N

1.10B04.1G

BCSU6

5.0B04.1J

- CHES027 LAN Downlink

BSCC_3162 LANU1

1.10B04.1P

1.10B04.1J

BCSU6

5.0B05.1J

- CHES027 LAN Downlink

BSCC_3161 LANU1

1.10B04.2A

1.10B04.1L

BCSU5

4.8B06.1J

- CHES019 LAN Downlink

BSCC_3160 LANU1

1.10B04.2C

1.10B04.1N

BCSU5

4.8B07.1J

- CHES019 LAN Downlink

BSCC_3159 LANU1

1.10B04.2E

1.10B04.1P

BCSU5

4.8B03.1J

- CHES019 LAN Downlink

BSCC_3158 LANU1

1.10B04.2G

1.10B04.2A

BCSU5

4.8B04.1J

- CHES019 LAN Downlink

BSCC_3157 LANU1

1.10B04.2J

1.10B04.2C

BCSU5

4.8B05.1J

- CHES019 LAN Downlink

BSCC_3156 LANU1

1.10B04.2L

1.10B04.2E

BCSU4

4.4B06.1J

- CHES020 LAN Downlink

BSCC_3155 LANU1

1.10B04.2N

1.10B04.2G

BCSU4

4.4B07.1J

- CHES020 LAN Downlink

Page 50: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

50 (270)

BSCC_3154 LANU1

1.10B04.2P

1.10B04.2J

BCSU4

4.4B03.1J

- CHES021 LAN Downlink

BSCC_3153 LANU1

1.10B04.2R

1.10B04.2L

BCSU4

4.4B04.1J

- CHES021 LAN Downlink

BSCC_3152 LANU1

1.10B04.2T

1.10B04.2N

BCSU4

4.4B05.1J

- CHES021 LAN Downlink

BSCC_3183 LANU0

1.8B03.1C

1.8B03.1E

LANU1

1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_3184 LANU0

1.8B04.1C

1.8B03.1G

LANU1

1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

BSCC_3190 LANU0

1.8F03.ETH2

- LANU0

1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_3191 LANU1

1.10F03.ETH2

- LANU1

1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_3192 LANU0

1.8B02.1A

1.8B03.1C

LANU0

1.8B03.1A

1.8B05.2V

CHES008 LAN LDI

BSCC_3193 LANU1

1.10B02.1A

1.10B03.1A

LANU1

1.10B03.1A

1.10B05.2T

CHES008 LAN LDI

Add following cables.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4420 LANU0

1.8B05.2T

LANU0

1.8B03.1A

CHES006 ETPLAN Uplink&LDI

BSCC_4423 LANU1

1.10B05.2V

LANU1

1.10B03.1C

CHES006 ETPLAN Uplink&LDI

BSCC_4470 LANU0

1.8B02.1A

LANU0

1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU1

1.10B02.1A

LANU1

1.10B05.1A

CHES008 LAN LDI

BSCC_3182 LANU0

1.8B02.1E

LANU1

1.10B02.1E

CHES008 LAN Redund.1)

BSCC_4481 LANU0

1.8F03.ETH24

LANU0

1.8F04.ETH2

CNIX006 LAN LDI

BSCC_4483 LANU1

1.10F03.ETH24

LANU1

1.10F04.ETH2

CNIX006 LAN LDI

BSCC_4484 LANU0

1.8F04.ETH23

LANU1

1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU0

1.8F04.ETH24

LANU1

1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU0

1.8F05.ETH1

LANU1

1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU0

1.8F05.ETH2

LANU1

1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU0

1.8F05.ETH23

LANU1

1.10F05.ETH23

CNIX006 LAN Redund.

Page 51: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

51 (270)

BSCC_4489 LANU0

1.8F05.ETH24

LANU1

1.10F05.ETH24

CNIX006 LAN Redund.

Notes:To be added only in case upgrade to Flexi BSC was performed with C110707 older than revision 08.

9.3.4.2 For Upgraded Flexi BSC (2 cabinet)

9.3.4.2.1 Add new configurations to ESB cards manually. Refer BSC Site IP Connectivity Guidelinesand BSC Site IP Configuration Examples document for this.

Move and reconnect the following cables.

Equipping CABLE FROM CABLE TO

No FU OldPosition

NewPosition

FU OldPosition

NewPosition

Type Use Note

BSCC_420 LANU 0 1.8B02.1A

1.8B03.1C

LANU 0 1.8B03.1A

1.8B05.2V

CHES008 LAN LDI

BSCC_422 LANU 1 1.10B02.1A

1.10B03.1A

LANU 1 1.10B03.1A

1.10B05.2T

CHES008 LAN LDI

BSCC_2041 LANU 0 1.8B04.1G

1.8B04.1A

BCSU6

5.0B06.1G

- CHES028 LAN Downlink

BSCC_2040 LANU 0 1.8B04.1J

1.8B04.1C

BCSU6

5.0B07.1G

- CHES028 LAN Downlink

BSCC_2039 LANU 0 1.8B04.1L

1.8B04.1E

BCSU6

5.0B03.1G

- CHES028 LAN Downlink

BSCC_2038 LANU 0 1.8B04.1N

1.8B04.1G

BCSU6

5.0B04.1G

- CHES028 LAN Downlink

BSCC_2037 LANU 0 1.8B04.1P

1.8B04.1J

BCSU6

5.0B05.1G

- CHES028 LAN Downlink

BSCC_2036 LANU 0 1.8B04.2A

1.8B04.1L

BCSU5

4.8B06.1G

- CHES020 LAN Downlink

BSCC_2035 LANU 0 1.8B04.2C

1.8B04.1N

BCSU5

4.8B07.1G

- CHES020 LAN Downlink

BSCC_2034 LANU 0 1.8B04.2E

1.8B04.1P

BCSU5

4.8B03.1G

- CHES020 LAN Downlink

BSCC_2033 LANU 0 1.8B04.2G

1.8B04.2A

BCSU5

4.8B04.1G

- CHES020 LAN Downlink

BSCC_2032 LANU 0 1.8B04.2J

1.8B04.2C

BCSU5

4.8B05.1G

- CHES020 LAN Downlink

BSCC_2031 LANU 0 1.8B04.2L

1.8B04.2E

BCSU4

4.4B06.1G

- CHES021 LAN Downlink

BSCC_2030 LANU 0 1.8B04.2N

1.8B04.2G

BCSU4

4.4B07.1G

- CHES021 LAN Downlink

BSCC_2029 LANU 0 1.8B04.2P

1.8B04.2J

BCSU4

4.4B03.1G

- CHES022 LAN Downlink

BSCC_2028 LANU 0 1.8B04.2R

1.8B04.2L

BCSU4

4.4B04.1G

- CHES022 LAN Downlink

BSCC_2027 LANU 0 1.8B04.2T

1.8B04.2N

BCSU4

4.4B05.1G

- CHES022 LAN Downlink

Page 52: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

52 (270)

BSCC_2026 LANU 0 1.8B04.2V

1.8B04.2P

BCSU3

4.0B06.1G

- CHES024 LAN Downlink

BSCC_2025 LANU 0 1.8B04.2X

1.8B04.2R

BCSU3

4.0B07.1G

- CHES024 LAN Downlink

BSCC_2024 LANU 0 1.8B03.1E

1.8B04.2T

BCSU3

4.0B03.1G

- CHES024 LAN Downlink

BSCC_2023 LANU 0 1.8B03.1G

1.8B04.2V

BCSU3

4.0B04.1G

- CHES024 LAN Downlink

BSCC_2022 LANU 0 1.8B03.1J

1.8B04.2X

BCSU3

4.0B05.1G

- CHES024 LAN Downlink

BSCC_2081 LANU 1 1.10B04.1G

1.10B04.1A

BCSU6

5.0B06.1J

CHES027 LAN Downlink

BSCC_2080 LANU 1 1.10B04.1J

1.10B04.1C

BCSU6

5.0B07.1J

CHES027 LAN Downlink

BSCC_2079 LANU 1 1.10B04.1L

1.10B04.1E

BCSU6

5.0B03.1J

CHES027 LAN Downlink

BSCC_2078 LANU 1 1.10B04.1N

1.10B04.1G

BCSU6

5.0B04.1J

CHES027 LAN Downlink

BSCC_2077 LANU 1 1.10B04.1P

1.10B04.1J

BCSU6

5.0B05.1J

CHES027 LAN Downlink

BSCC_2076 LANU 1 1.10B04.2A

1.10B04.1L

BCSU5

4.8B06.1J

CHES019 LAN Downlink

BSCC_2075 LANU 1 1.10B04.2C

1.10B04.1N

BCSU5

4.8B07.1J

CHES019 LAN Downlink

BSCC_2074 LANU 1 1.10B04.2E

1.10B04.1P

BCSU5

4.8B03.1J

CHES019 LAN Downlink

BSCC_2073 LANU 1 1.10B04.2G

1.10B04.2A

BCSU5

4.8B04.1J

CHES019 LAN Downlink

BSCC_2072 LANU 1 1.10B04.2J

1.10B04.2C

BCSU5

4.8B05.1J

CHES019 LAN Downlink

BSCC_2071 LANU 1 1.10B04.2L

1.10B04.2E

BCSU4

4.4B06.1J

- CHES020 LAN Downlink

BSCC_2070 LANU 1 1.10B04.2N

1.10B04.2G

BCSU4

4.4B07.1J

- CHES020 LAN Downlink

BSCC_2069 LANU 1 1.10B04.2P

1.10B04.2J

BCSU4

4.4B03.1J

- CHES021 LAN Downlink

BSCC_2068 LANU 1 1.10B04.2R

1.10B04.2L

BCSU4

4.4B04.1J

- CHES021 LAN Downlink

BSCC_2067 LANU 1 1.10B04.2T

1.10B04.2N

BCSU4

4.4B05.1J

- CHES021 LAN Downlink

BSCC_2066 LANU 1 1.10B04.2V

1.10B04.2P

BCSU3

4.0B06.1J

- CHES023 LAN Downlink

BSCC_2065 LANU 1 1.10B04.2X

1.10B04.2R

BCSU3

4.0B07.1J

- CHES023 LAN Downlink

BSCC_2064 LANU 1 1.10B03.1E

1.10B04.2T

BCSU3

4.0B03.1J

- CHES023 LAN Downlink

BSCC_2063 LANU 1 1.10B03.1G

1.10B04.2V

BCSU3

4.0B04.1J

- CHES023 LAN Downlink

BSCC_2062 LANU 1 1.10B03.1J

1.10B04.2X

BCSU3

4.0B05.1J

- CHES023 LAN Downlink

BSCC_2095 LANU 0 1.8F03.ETH2

- LANU 0 1.8F04.ETH2

1.8F04.ETH1

CNIX006 LAN Uplink&LDI

BSCC_2096 LANU 1 1.10F03.ETH2

- LANU 1 1.10F04.ETH2

1.10F04.ETH1

CNIX006 LAN Uplink&LDI

Page 53: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

53 (270)

BSCC_2193 LANU 0 1.8B03.1C

1.8B03.1E

LANU 1 1.10B03.1C

1.10B03.1E

CHES008 LAN Redund.

BSCC_2194 LANU 0 1.8B04.1C

1.8B03.1G

LANU 1 1.10B04.1C

1.10B03.1G

CHES008 LAN Redund.

Add following cables.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4420 LANU0

1.8B05.2T

LANU0

1.8B03.1A

CHES006 ETPLAN Uplink&LDI.

BSCC_4423 LANU1

1.10B05.2V

LANU1

1.10B03.1C

CHES006 ETPLAN Uplink&LDI.

BSCC_4470 LANU0

1.8B02.1A

LANU0

1.8B05.1A

CHES008 LAN LDI

BSCC_4472 LANU1

1.10B02.1A

LANU1

1.10B05.1A

CHES008 LAN LDI

BSCC_3182 LANU0

1.8B02.1E

LANU1

1.10B02.1E

CHES008 LAN Redund.1)

BSCC_4481 LANU0

1.8F03.ETH24

LANU0

1.8F04.ETH2

CNIX006 LAN Uplink&LDI

BSCC_4483 LANU1

1.10F03.ETH24

LANU1

1.10F04.ETH2

CNIX006 LAN Uplink&LDI

BSCC_4484 LANU0

1.8F04.ETH23

LANU1

1.10F04.ETH23

CNIX006 LAN Redund.

BSCC_4485 LANU0

1.8F04.ETH24

LANU1

1.10F04.ETH24

CNIX006 LAN Redund.

BSCC_4486 LANU0

1.8F05.ETH1

LANU1

1.10F05.ETH1

CNIX006 LAN Redund.

BSCC_4487 LANU0

1.8F05.ETH2

LANU1

1.10F05.ETH2

CNIX006 LAN Redund.

BSCC_4488 LANU0

1.8F05.ETH23

LANU1

1.10F05.ETH23

CNIX006 LAN Redund.

BSCC_4489 LANU0

1.8F05.ETH24

LANU1

1.10F05.ETH24

CNIX006 LAN Redund.

Notes:To be added only in case upgrade to Flexi BSC was performed with C110707 older than revision 08.

Reconnect outgoing uplink cables back to top of CPRJ45-A.

Page 54: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

54 (270)

9.4 Change topology

For BSC 3i 1000/2000

If not T10 or T11 change it with following command.ZW6G:T10;ZW6G:T11;

Note: T10 topology- optical uplinks are in use at panel on cabinets roof T11 topology- electrical uplinks are in use at panel on cabinets roof

For upgraded Flexi Single cabinet/Double cabinet

If not T8 change it with following command.ZW6G:T8;

There has been a recommendation that when ETPLAN is configured the O&M IP address of OMU is reconfiguredon VLAN-10 interface. Note that if host port VLAN tagging is used in OMU Ethernet interface then also the switchside port has to be configured as tagged. O&M IP address reconfiguration on VLAN interface when configuringETPLAN is not recommended anymore in the BSC site IP connectivity guidelines. O&M IP address on OMU cankeep on using the physical EL0 and EL1 interfaces.

In case of O&M traffic separation:Enable OMU separation from O&M LAN using following commandZW6K:ENA;

9.5 Configure SWU 6 and 7 to the HW database

9.5.1 For BSC 3i 1000/2000

ZWTU:SWU,6:IA5-0;ZWTP:SWU,6:ESB24_D,3,5;ZWTU:SWU,7:IA5-2;ZWTP:SWU,7:ESB24_D,3,5;

9.5.2 For Upgraded Flexi Single cabinet / Double cabinet

ZWTU:SWU,6:1A001-08;ZWTP:SWU,6:ESB24_D,3,5;ZWTU:SWU,7: 1A001-10;ZWTP:SWU,7:ESB24_D,4,5;

9.6 Check internal LAN index with command

ZWYI:L;

9.7 Add SWUs to the internal LAN:

ZWYC:<internal_LAN_index>:SWU,6:MCMU,<active_unit_index>;ZWYC:<internal_LAN_index>:SWU,7:MCMU,<active_unit_index>;

Page 55: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

55 (270)

9.8 Change all SWUs state to the WO-EX

ZUSC:SWU,<unit index>:SE;ZUSC:SWU,<unit index>:TE;ZUSC:SWU,<unit index>:WO;

9.9 Activate all SWU s back to use

ZW6E:SWU,<Unit index>:A:;

10 CREATE ETPSIG-I IP ADDRESS TO MCMU AND BCSU

ETPE, ETPT and ETPA cards provide an untagged interface for ETP management (ETPSIG-m) and control(ETPSIG-c) traffic.

Note:MCMU will be DCHP server and mainitains FTP server connection.

Create ETPSIG-I in MCMUs.ZQRA:MCMU,<index>::EL0;ZQRA:MCMU,<index>::EL1;ZQRA:MCMU,<index>::<Vlan name>,<Vlan id>,EL0,,::;ZQRA:MCMU,<index>::<Vlan name>,<Vlan id>,EL1,,::;ZQRN:MCMU,<index>::<Vlan name>,<Vlan name(back up)>:"<ip address>",<subnet mask>,L,IM;

Example,ZQRA:MCMU,0::EL0;ZQRA:MCMU,0::EL1;ZQRA:MCMU,0::VLAN20,20,EL0,,::;ZQRA:MCMU,0::VLAN21,20,EL1,,::;ZQRN:MCMU,0::VLAN20,VLAN21:"10.0.1.11",26,L,IM;

Configure ETPSIG-M&C IP address to BCSU(s) / EL0 & EL1 interfaces ZQRN:BCSU,<unit_index>::EL0,EL1:"<ip_address>",<net_mask_length>,L,IMC::

Configure ETPSIG-M&C IP address to BCSU(s)/VLAN interfaces

ZQRA:BCSU,<unit_index>::<VLAN Name>,<VLAN ID>,EL0,::;ZQRA:BCSU,<unit_index>:: <VLAN Name>,<VLAN ID>,EL1,::;ZQRN:BCSU,<unit_index>::<VLAN Name>,:"<ip_address>",<net_mask_length>,L,IMC::

Example,ZQRA:BCSU,0::VLAN20,20,EL0,:::;ZQRA:BCSU,0::VLAN21,20,EL1,:::;ZQRN:BCSU,0::VLAN20,VLAN21:"10.0.1.1",26,L,IMC:;

Page 56: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

56 (270)

11 PACKET ABIS OVER ETHERNET(ETPE), PIU TYPE ETP

The following pop up will be displayed by macro for each BSC variants.

Select the required application and tracks to proceed further.

11.1 Creation of ETPE unit with transmission/line protection

Check the source configuration for overlapping PCM areas and Plug-in units.

Note!Macro ask in this point redundancy type and Plug-in Unit location. After that macro check possibleunit/PCM overlapping.

If there is overlapping PCM areas move or remove resources from them. Macro will remove unit and Plug-in Unitsautomatically after needed recourses are moved or removed.

Note:- Refer Appendix 2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

Page 57: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

57 (270)

11.1.1 Install Plug-in units, terminators and cables

11.1.1.1 Terminators and setting modules

For initial BSC 3i 1000/2000/Upgraded Flexi BSC

For BSC 3i 1000/Upgraded Flexi Single cabinetTerminators and setting modules

Position ID Name FU Cabinet Use NoteETPEINDEX

5.6B 014E C108719 ADMOD00 GTIC 0 BSCC For ETPE 1)

ETPE 0-0

5.6B 064E C108719 ADMOD00 GTIC 0 BSCC For ETPE 1)

ETPE 1-0

5.6B09.2J C101501 CABID1A GTIC 0 BSCC

Cabinetidentification

ETPE 0-0

5.6B09.2L C101557 CARID53 GTIC 0 BSCC

Cartridgeidentification

ETPE 1-0

Notes:When ETP PIU is used as ETPE in this slot.

For BSC 3i 2000/Upgraded Flexi Double cabinet.Terminators and setting modules

Position ID Name FU Cabinet Use NoteETPEINDEX

2.0B 064E C108719 ADMOD00 ETC 2 BSCD For ETPE 1) ETPE 3-02.3B 064E C108719 ADMOD00 ETC 3 BSCD For ETPE 1) ETPE 11-02.6B 014E C108719 ADMOD00 ETC 4 BSCD For ETPE 1) ETPE 4-02.6B 064E C108719 ADMOD00 ETC 4 BSCD For ETPE 1) ETPE 5-02.9B 014E C108719 ADMOD00 ETC 5 BSCD For ETPE 1) ETPE 12-02.9B 064E C108719 ADMOD00 ETC 5 BSCD For ETPE 1) ETPE 13-0

2.0B09.2J C101502 CABID1B ETC 2 BSCD

Cabinetidentification ETPE 3-0

2.0B09.2L C101535 CARID20 ETC 2 BSCD

Cartridgeidentification ETPE 3-0

2.3B09.2J C101502 CABID1B ETC 3 BSCD

Cabinetidentification ETPE 11-0

2.3B09.2L C101536 CARID21 ETC 3 BSCD

Cartridgeidentification ETPE 11-0

2.6B09.2J C101502 CABID1B ETC 4 BSCD

Cabinetidentification

ETPE 4-0/ETPE 5-0

2.6B09.2L C101538 CARID23 ETC 4 BSCD

Cartridgeidentification

ETPE 4-0/ETPE 5-0

Page 58: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

58 (270)

2.9B09.2J C101502 CABID1B ETC 5 BSCD

Cabinetidentification

ETPE 12-0/ETPE13-0

2.9B09.2L C101539 CARID24 ETC 5 BSCD

Cartridgeidentification

ETPE 12-0/ETPE13-0

Notes:1) When ETP PIU is used as ETPE in this slot.

11.1.1.2 Plug-in unit installation

11.1.1.2.1 For BSC 3i 1000/2000/Upgraded Flexi BSC.

For BSC 3i 1000/ Upgraded Flexi Single Cabinet.

Catridge SGC1Cposition

Unit Cartridge /Slots

ETPEgroupindex

5.6 GTIC-0

1 0-0

5.6 GTIC-0

6 1-0

Note:Check Appendix 5 for ETP strappings.

For BSC 3i 2000/Upgraded Flexi Double cabinet.

Catridge SGC1Cposition

Unit Cartridge /Slots

ETPEgroupindex

2.0 ETC-2 6 3-02.3 ETC-3 6 11-02.6 ETC-4 1 4-02.6 ETC-4 6 5-0

Page 59: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

59 (270)

2.9 ETC-5 1 12-02.9 ETC-5 6 13-0

Note:Check Appendix 5 for ETP strappings.

11.1.1.3 Cabling

11.1.1.3.1 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 SE-NH state

ZUSC:MCMU,0:SP; If neededZUSC:MCMU,0:TE;ZUSC:MCMU,0:SE;ZUSC:MCMU,0:SE;

ZUSC:EMB,0:SP; If neededZUSC:EMB,0:TE; ZUSC:EMB,0:SE;ZUSC:EMB,0:SE;

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

Page 60: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

60 (270)

11.1.1.3.1.1 For initial BSC 3i 1000/200011.1.1.3.1.1.1 For BSC 3i 1000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC0

5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC0

5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

Notes:1)These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_714 BSCC GTIC0

5.6F02.SB1-0

BSCC GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

ETPE 0-0

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC0

5.6F02.SB2-0

BSCC GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

ETPE 0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC GTIC1

5.9F01.SB1-0

BSCC GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 1)

ETPE 1-0

GTIC0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC GTIC1

5.9F01.SB2-0

BSCC GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 1)

ETPE 1-0

GTIC0

5.6F07.SB3-0

1.0F08.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Page 61: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

61 (270)

Added ETPLAN from LANU-0 for the required tracks.

Equipping CABLE FROM CABLE TOETPEINDEXNo FU Position FU Position Type Use Note

BSCC_4400 LANU 0 5.0B05.2E

GTIC 0 5.6B06.4G

CHES009 ETPLANETPE 1-0

BSCC_4402 LANU 0 5.0B05.2J

GTIC 0 5.6B01.4G

CHES008 ETPLANETPE 0-0

11.1.1.3.1.1.2 For BSC 3i 2000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 0 5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 0 5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_718 GTIC 0 5.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 2)

BSCC_719 GTIC 0 5.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 2)

BSCC_730 GTIC 1 5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 3)

BSCC_731 GTIC 1 5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 3)

BSCC_734 GTIC 1 5.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 4)

BSCC_735 GTIC 1 5.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 4)

Notes:1)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3)These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4)These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Added ETPLAN from LANU-0 for the required tracks

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPEINDEX

BSCC_4302 LANU0

5.0B05.1E

BSCCETC

2.0B06.4G

BSCD CHES044 ETPLAN ETPE3-0

Page 62: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

62 (270)

2

BSCC_4305 LANU0

5.0B05.1L

BSCCETC3

2.3B06.4G

BSCD CHES042 ETPLANETPE11-0

BSCC_4306 LANU0

5.0B05.1N

BSCCETC4

2.6B01.4G

BSCD CHES042 ETPLANETPE4-0

BSCC_4307 LANU0

5.0B05.1P

BSCCETC4

2.6B06.4G

BSCD CHES041 ETPLANETPE5-0

BSCC_4308 LANU0

5.0B05.1R

BSCCETC5

2.9B01.4G

BSCD CHES041 ETPLANETPE12-0

BSCC_4309 LANU0

5.0B05.2C

BSCCETC5

2.9B06.4G

BSCD CHES040 ETPLANETPE13-0

Added Hotlink cables if required

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use Note ETPEINDEX

BSCD_4350ETC4

2.6F07.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB027 Hotlink 1) ETPE 5-0

BSCD_4352 ETC4

2.6F02.SB2-0

BSCD GSW2KB0

1.0F01.SB2-0

BSCC CSB027 Hotlink 1) ETPE 4-0

BSCD_4354 ETC2

2.0F07.SB2-0

BSCD GSW2KB0

1.0F07.SB3-0

BSCC CSB022 Hotlink 1) ETPE 3-0

BSCD_4356 ETC5

2.9F07.SB2-0

BSCD GSW2KB0

1.0F07.SB2-0

BSCC CSB029 Hotlink 1) ETPE13-0

BSCD_4358 ETC5

2.9F02.SB2-0

BSCD GSW2KB0

1.0F08.SB2-0

BSCC CSB027 Hotlink 1) ETPE12-0

BSCD_4360 ETC3

2.3F07.SB2-0

BSCD GSW2KB0

1.0F02.SB2-0

BSCC CSB027 Hotlink 1) ETPE11-0

BSCD_4362 ETC4

2.6F07.SB3-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB027 Hotlink 1), ETPE 5-0

BSCD_4364 ETC4

2.6F02.SB3-0

BSCD GSW2KB0

1.0F01.SB4-0

BSCC CSB027 Hotlink 1), ETPE 4-0

BSCD_4366 ETC2

2.0F07.SB3-0

BSCD GSW2KB0

1.0F07.SB4-0

BSCC CSB021 Hotlink 1), ETPE 3-0

BSCD_4368 ETC5

2.9F07.SB3-0

BSCD GSW2KB0

1.0F06.SB2-0

BSCC CSB029 Hotlink 1), ETPE13-0

BSCD_4370 ETC5

2.9F02.SB3-0

BSCD GSW2KB0

1.0F08.SB1-0

BSCC CSB029 Hotlink 1), ETPE12-0

BSCD_4372 ETC3

2.3F07.SB3-0

BSCD GSW2KB0

1.0F02.SB4-0

BSCC CSB024 Hotlink 1), ETPE11-0

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s).

11.1.1.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet

11.1.1.3.1.2.1 For upgraded flexi BSC Single cabinet.

Remove cables if required.

Page 63: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

63 (270)

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC0

5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC0

5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

Notes:These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_715 BSCC GTIC0

5.6F02.SB2-0

BSCC GSW2KB0

1.0F02.SB4-0

CSB030 2)

ETPE0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC GTIC1

5.9F01.SB1-0

BSCC GSW2KB0

1.0F06.SB2-0

CSB027 1)

ETPE1-0

GTIC0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC GTIC1

5.9F01.SB2-0

BSCC GSW2KB0

1.0F07.SB2-0

CSB027 1)

ETPE1-0

GTIC0

5.6F07.SB3-0

1.0F08.SB1-1

BSCC_714 BSCC GTIC0

5.6F02.SB1-0

BSCC GSW2KB0

1.0F02.SB2-0

CSB031 2)

ETPE0-0

5.6F02.SB2-0

1.0F02.SB2-1

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Add following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4400 LANU0

1.8B05.2G

GTIC 0 5.6B06.4G

CHES023 ETPLAN ETPE1-0

BSCC_4402 LANU0

1.8B05.2L

GTIC 0 5.6B01.4G

CHES024 ETPLAN ETPE0-0

Page 64: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

64 (270)

11.1.1.3.1.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC0

5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC0

5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_714 GTIC0

5.6F02.SB1-0

GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

BSCC_715 GTIC0

5.6F02.SB2-0

GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

BSCC_718 GTIC0

5.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 3)

BSCC_719 GTIC0

5.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 3)

BSCC_726 GTIC1

5.9F01.SB1-0

GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 4)

BSCC_727 GTIC1

5.9F01.SB2-0

GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 4)

BSCC_730 GTIC1

5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 5)

BSCC_731 GTIC1

5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 5)

BSCC_734 GTIC1

5.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 6)

BSCC_735 GTIC1

5.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Added ETPLAN from LANU-0 for the required tracks.

Equipping CABLE FROM CABLE TO

No FU Cabinet FU Cabinet Type Use Note ETPE

Page 65: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

65 (270)

Position Position INDEX

BSCC_4302 LANU0

1.8B05.1G

BSCCETC2

2.0B06.4G

BSCD CHES021 ETPLANETPE 3-0

BSCC_4305 LANU0

1.8B05.1N

BSCCETC3

2.3B06.4G

BSCD CHES024 ETPLANETPE11-0

BSCC_4306 LANU0

1.8B05.1P

BSCCETC4

2.6B01.4G

BSCD CHES026 ETPLANETPE 4-0

BSCC_4307 LANU0

1.8B05.1R

BSCCETC4

2.6B06.4G

BSCD CHES027 ETPLANETPE 5-0

BSCC_4308 LANU0

1.8B05.2C

BSCCETC5

2.9B01.4G

BSCD CHES028 ETPLANETPE12-0

BSCC_4309 LANU0

1.8B05.2E

BSCCETC5

2.9B06.4G

BSCD CHES029 ETPLANETPE13-0

Added Hotlink cables if required

CABLE TO

EquippingNo:

FU Position Cabinet FU Position Cabinet Type Use Note

ETPEINDEX

BSCD_4350

ETC4

2.6F07.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB027 Hotlink 1)

ETPE 5-0BSCD_4352 ETC

42.6F02.SB2-0

BSCD GSW2KB0

1.0F01.SB2-0

BSCC CSB027 Hotlink 1)

ETPE 4-0BSCD_4354 ETC

22.0F07.SB2-0

BSCD GSW2KB0

1.0F07.SB3-0

BSCC CSB022 Hotlink 1)

ETPE 3-0BSCD_4356 ETC

52.9F07.SB2-0

BSCD GSW2KB0

1.0F07.SB2-0

BSCC CSB029 Hotlink 1)ETPE 13-0

BSCD_4358 ETC5

2.9F02.SB2-0

BSCD GSW2KB0

1.0F08.SB2-0

BSCC CSB027 Hotlink 1)ETPE 12-0

BSCD_4360 ETC3

2.3F07.SB2-0

BSCD GSW2KB0

1.0F02.SB2-0

BSCC CSB027 Hotlink 1)ETPE 11-0

BSCD_4362 ETC4

2.6F07.SB3-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB027 Hotlink 1),

ETPE 5-0BSCD_4364 ETC

42.6F02.SB3-0

BSCD GSW2KB0

1.0F01.SB4-0

BSCC CSB027 Hotlink 1),

ETPE 4-0BSCD_4366 ETC

22.0F07.SB3-0

BSCD GSW2KB0

1.0F07.SB4-0

BSCC CSB021 Hotlink 1),

ETPE 3-0BSCD_4368 ETC

52.9F07.SB3-0

BSCD GSW2KB0

1.0F06.SB2-0

BSCC CSB029 Hotlink 1),ETPE 13-0

Page 66: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

66 (270)

BSCD_4370 ETC5

2.9F02.SB3-0

BSCD GSW2KB0

1.0F08.SB1-0

BSCC CSB029 Hotlink 1),ETPE 12-0

BSCD_4372 ETC3

2.3F07.SB3-0

BSCD GSW2KB0

1.0F02.SB4-0

BSCC CSB024 Hotlink 1),ETPE 11-0

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

Check SW256B dip switching. See appendix 1

11.1.1.3.2 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:MCMU,0:SE;ZUSC:MCMU,0:TE;ZUSC:MCMU,0:SP;ZUSC:MCMU,0:WO;

ZUSC:EMB,0:SE; ZUSC:EMB,0:TE; ZUSC:EMB,0:SP; ZUSC:EMB,0:WO;

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;

11.1.1.3.3 Change MCMU-1, SWU-1, SWU-3, SWU-5 and SWU-7 SE-NH state

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SE;ZUSC:MCMU,1:SE;

ZUSC:EMB,1:TE;ZUSC:EMB,1:SE;ZUSC:EMB,1:SE;

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;ZUSC:SWU,3:SE;

ZUSC:SWU,5:TE;

Page 67: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

67 (270)

ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

11.1.1.3.3.1 For initial BSC 3i 1000/2000.

11.1.1.3.3.1.1 For BSC 3i 1000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add following cables if required

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716 BSCC GTIC0

5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2)

5.6F02.SB2-1

1.3F02.SB2-1 ETPE 0-0

BSCC_717 BSCC GTIC0

5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

5.6F02.SB3-1

1.3F02.SB4-1 ETPE 0-0

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1)

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1 ETPE 1-0

BSCC_729 BSCC GTIC1

5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1)

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1 ETPE 1-0

Page 68: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

68 (270)

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Added ETPLAN from LANU-1 for the required tracks

Equipping CABLE FROM CABLE TOETPEINDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU 1 5.2B05.2E

GTIC 0 5.6B06.4J

CHES008 ETPLANETPE 1-0

BSCC_4408 LANU 1 5.2B05.2J

GTIC 0 5.6B01.4J

CHES007 ETPLANETPE 0-0

11.1.1.3.3.1.2 For BSC 3i 2000

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_720 GTIC 0 5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 2)

BSCC_721 GTIC 0 5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 2)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 3)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 3)

BSCC_736 GTIC 1 5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 4)

BSCC_737 GTIC 1 5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 4)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Added ETPLAN from LANU-1 for the required tracks

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use Note

Page 69: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

69 (270)

BSCC_4312 LANU1

5.2B05.1E

BSCC ETC2

2.0B06.4J

BSCD CHES042 ETPLAN ETPE3-0

BSCC_4315 LANU1

5.2B05.1L

BSCC ETC3

2.3B06.4J

BSCD CHES040 ETPLAN ETPE11-0

BSCC_4316 LANU1

5.2B05.1N

BSCC ETC4

2.6B01.4J

BSCD CHES040 ETPLAN ETPE4-0

BSCC_4317 LANU1

5.2B05.1P

BSCC ETC4

2.6B06.4J

BSCD CHES039 ETPLAN ETPE5-0

BSCC_4318 LANU1

5.2B05.1R

BSCC ETC5

2.9B01.4J

BSCD CHES039 ETPLAN ETPE12-0

BSCC_4319 LANU1

5.2B05.2C

BSCC ETC5

2.9B06.4J

BSCD CHES038 ETPLAN ETPE13-0

Added Hotlinks if required

Equipping CABLE TO

No Position Cabinet FUPosition

Cabinet Type Use NoteETPEINDEX

BSCD_4351 ETC4

2.6F07.SB2-1

BSCD GSW2KB1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPE5-0

BSCD_4353 ETC4

2.6F02.SB2-1

BSCD GSW2KB1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPE4-0

BSCD_4355 ETC2

2.0F07.SB2-1

BSCD GSW2KB1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPE3-0

BSCD_4357 ETC5

2.9F07.SB2-1

BSCD GSW2KB1

1.3F07.SB2-0

BSCC CSB027 Hotlink 1)ETPE13-0

BSCD_4359 ETC5

2.9F02.SB2-1

BSCD GSW2KB1

1.3F08.SB2-0

BSCC CSB026 Hotlink 1)ETPE12-0

BSCD_4361 ETC3

2.3F07.SB2-1

BSCD GSW2KB1

1.3F02.SB2-0

BSCC CSB025 Hotlink 1)ETPE11-0

BSCD_4363 ETC4

2.6F07.SB3-1

BSCD GSW2KB1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1),ETPE5-0

BSCD_4365 ETC4

2.6F02.SB3-1

BSCD GSW2KB1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1),ETPE4-0

BSCD_4367 ETC2

2.0F07.SB3-1

BSCD GSW2KB1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1),ETPE3-0

BSCD_4369 ETC5

2.9F07.SB3-1

BSCD GSW2KB1

1.3F06.SB2-0

BSCC CSB027 Hotlink 1),ETPE13-0

BSCD_4371 ETC5

2.9F02.SB3-1

BSCD GSW2KB1

1.3F08.SB1-0

BSCC CSB027 Hotlink 1),ETPE12-0

BSCD_4373 ETC3

2.3F07.SB3-1

BSCD GSW2KB1

1.3F02.SB4-0

BSCC CSB022 Hotlink 1),ETPE11-0

Page 70: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

70 (270)

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

11.1.1.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet11.1.1.3.3.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add following cables if required

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_717 BSCC GTIC0

5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 2)

5.6F02.SB3-1

1.3F02.SB4-1

ETPE0-0

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 1)

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

ETPE1-0

BSCC_729 BSCC GTIC1

5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 1)

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

ETPE1-0

BSCC_716 BSCC GTIC0

5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 2)

5.6F02.SB2-1

1.3F02.SB2-1

ETPE0-0

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.

Page 71: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

71 (270)

1) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Add following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4406 LANU 1 1.10B05.2G

GTIC0

5.6B06.4J

CHES022 ETPLAN ETPE1-0

BSCC_4408 LANU 1 1.10B05.2L

GTIC0

5.6B01.4J

CHES023 ETPLAN ETPE0-0

11.1.1.3.3.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_716 GTIC 0 5.6F02.SB1-1

GSW2KB1

1.3F02.SB2-0

CSB029 Hotlink 2)

BSCC_717 GTIC 0 5.6F02.SB2-1

GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

BSCC_720 GTIC 0 5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 3)

BSCC_721 GTIC 0 5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 3)

BSCC_728 GTIC 1 5.9F01.SB1-1

GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 4)

BSCC_729 GTIC 1 5.9F01.SB2-1

GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 4)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 5)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 5)

BSCC_736 GTIC 1 5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 6)

BSCC_737 GTIC 1 5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 6)

Page 72: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

72 (270)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Added ETPLAN from LANU-0 for the required tracks.

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet

FUPosition

Cabinet

Type Use Note ETPE

INDEXBSCC_4312

LANU 1

1.10B05.1G

BSCCETC 2

2.0B06.4J

BSCD CHES023

ETPLAN ETPE 3-

0BSCC_4315

LANU 1

1.10B05.1N

BSCCETC 3

2.3B06.4J

BSCD CHES026

ETPLAN ETPE

11-0BSCC_4316

LANU 1

1.10B05.1P

BSCCETC 4

2.6B01.4J

BSCD CHES028

ETPLAN ETPE 4-

0BSCC_4317

LANU 1

1.10B05.1R

BSCCETC 4

2.6B06.4J

BSCD CHES029

ETPLAN ETPE 5-

0BSCC_4318

LANU 1

1.10B05.2C

BSCCETC 5

2.9B01.4J

BSCD CHES030

ETPLAN ETPE

12-0BSCC_4319

LANU 1

1.10B05.2E

BSCCETC 5

2.9B06.4J

BSCD CHES031

ETPLAN ETPE

13-0

Added Hotlink cables if required

Equipping CABLE TO

No Position Cabinet FUPosition

Cabinet Type Use NoteETPEINDEX

BSCD_4351 ETC4

2.6F07.SB2-1

BSCD GSW2KB1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPE5-0

BSCD_4353 ETC4

2.6F02.SB2-1

BSCD GSW2KB1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPE4-0

BSCD_4355 ETC2

2.0F07.SB2-1

BSCD GSW2KB1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPE3-0

BSCD_4357 ETC5

2.9F07.SB2-1

BSCD GSW2KB1

1.3F07.SB2-0

BSCC CSB027 Hotlink 1)ETPE13-0

BSCD_4359 ETC5

2.9F02.SB2-1

BSCD GSW2KB1

1.3F08.SB2-0

BSCC CSB026 Hotlink 1)ETPE12-0

BSCD_4361 ETC3

2.3F07.SB2-

BSCD GSW2KB1

1.3F02.SB2-

BSCC CSB025 Hotlink 1) ETPE11-0

Page 73: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

73 (270)

1 0

BSCD_4363 ETC4

2.6F07.SB3-1

BSCD GSW2KB1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1),ETPE5-0

BSCD_4365 ETC4

2.6F02.SB3-1

BSCD GSW2KB1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1),ETPE4-0

BSCD_4367 ETC2

2.0F07.SB3-1

BSCD GSW2KB1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1),ETPE3-0

BSCD_4369 ETC5

2.9F07.SB3-1

BSCD GSW2KB1

1.3F06.SB2-0

BSCC CSB027 Hotlink 1),ETPE13-0

BSCD_4371 ETC5

2.9F02.SB3-1

BSCD GSW2KB1

1.3F08.SB1-0

BSCC CSB027 Hotlink 1),ETPE12-0

BSCD_4373 ETC3

2.3F07.SB3-1

BSCD GSW2KB1

1.3F02.SB4-0

BSCC CSB022 Hotlink 1),ETPE11-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

Check SW256B dips switching. See appendix 1

11.1.1.3.4 Change MCMU-1 to SP-EX, SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:MCMU,1:SE;ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SP;

ZUSC:EMB,1:SE;ZUSC;EMB,1:TE;ZUSC:EMB,1:SP;

ZUSC:SWU,1:SE;ZUSC:SWU,1:TE;ZUSC:SWU,1:WO;

ZUSC:SWU,3:SE;ZUSC:SWU,3:TE;ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE;ZUSC:SWU,5:TE;ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE;ZUSC:SWU,7:TE;ZUSC:SWU,7:WO;

11.1.2 Create HW configuration

Create cartridges if not exist (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double Cabinet)

GTIC-0 cartridge:ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

Page 74: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

74 (270)

GTIC-1 catridge:ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 catridge:ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 catridge: ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 catridge:ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 catridge:ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

Create ETPE functional unit (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double Cabinet)

For BSC 3i 1000/Upgraded flexi BSC single cabinet.ZWTU:ETPE,0,0:1A5-6;ZWTU:ETPE,1,0:1A5-6;

For BSC 3i 2000/Upgraded flexi BSC double cabinet.ZWTU:ETPE,3,0:1B2-0;ZWTU:ETPE,11,0:1B2-3;ZWTU:ETPE,4,0:1B2-6;ZWTU:ETPE,5,0:1B2-6;ZWTU:ETPE,12,0:1B2-9;ZWTU:ETPE,13,0:1B2-9;

Create ETPE plug-in unit (ini BSC 3i 1000/2000,Upgraded Flexi single/Double Cabinet)For BSC 3i 1000/Upgraded flexi BSC single cabinet.ZWTP:ETPE,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPE,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;

For BSC 3i 2000/Upgraded flexi BSC double cabinet.ZWTP:ETPE,3,0:ETP,0,6::ETPCS,8,1664&&1727,TSL,0&&31:ETPPS,8,1728&&1791,TSL,0&&31::;ZWTP:ETPE,11,0:ETP,0,6::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPE,4,0:ETP,0,1::ETPCS,8,64&&127,TSL,0&&31:ETPPS,8,192&&255,TSL,0&&31::;ZWTP:ETPE,5,0:ETP,0,6::ETPCS,8,1088&&1151,TSL,0&&31:ETPPS,8,1216&&1279,TSL,0&&31::;ZWTP:ETPE,12,0:ETP,0,1::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;ZWTP:ETPE,13,0:ETP,0,6::ETPCS,8,1600&&1663,TSL,0&&31:ETPPS,8,1344&&1407,TSL,0&&31::;

Note:For legacy A-interface: Hotlinks are connected from port 0&1 to GSWs. ETPCS functionality is created in plugin unit to support legacy A interface.For A over IP: Traffic will be routed though EEP interface created (via ETPA card).For PS via PCU2_E cards: No separate PCMs are required. This will use PEPeth link created in ETP cards tocommunicate with PCU2_E cards in BCSU.For PS via PCU2_D cards: Hotlinks are connected from port 2&3 to GSWs. ETPPS functionality is created inplug in unit to support PS calls via PCU2_D cards(PEP HDLC link)

Connect functional unitsZWUC:ETPE,<pair_number>,<unit_index>:ETP,0:IF=ABIS:;

Note: This command is required only if PCMs are created in ETP plug in units

Page 75: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

75 (270)

Connect hotlink ports

ZWTA:GSW,0:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPE,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:GSW,1:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPE,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

For initial BSC 3i 1000/2000, Upgraded Flexi single/Double Cabinet

For BSC 3i 1000/Upgraded flexi BSC single cabinet.

ETPE 0-0

ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPE,0,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPE,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPE,0,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPE,0,0:ETP,0:HOTLINK,3:;

ETPE 1-0

ZWTA:GSW,0:SW256B,7:HOTLINK,3:ETPE,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,3:ETPE,1,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPE,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPE,1,0:ETP,0:HOTLINK,3:;

For BSC 3i 2000/Upgraded flexi BSC double cabinet.

ETPE 3-0

ZWTA:GSW,0:SW256B,6:HOTLINK,4:ETPE,3,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,4:ETPE,3,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,6:ETPE,3,0:ETP,0:HOTLINK,2:; ZWTA:GSW,1:SW256B,6:HOTLINK,6:ETPE,3,0:ETP,0:HOTLINK,3:;

ETPE 11-0

ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPE,11,0:ETP,0:HOTLINK,0:; ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPE,11,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPE,11,0:ETP,0:HOTLINK,2:; ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPE,11,0:ETP,0:HOTLINK,3:;

ETPE 5-0

ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPE,5,0:ETP,0:HOTLINK,0:; ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPE,5,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPE,5,0:ETP,0:HOTLINK,2:; ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPE,5,0:ETP,0:HOTLINK,3:;

Page 76: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

76 (270)

ETPE 4-0

ZWTA:GSW,0:SW256B,0:HOTLINK,2:ETPE,4,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,2:ETPE,4,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,6:ETPE,4,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,6:ETPE,4,0:ETP,0:HOTLINK,3:;

ETPE 13-0

ZWTA:GSW,0:SW256B,6:HOTLINK,2:ETPE,13,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,2:ETPE,13,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,5:HOTLINK,2:ETPE,13,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,2:ETPE,13,0:ETP,0:HOTLINK,3:;

ETPE 12-0

ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPE,12,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPE,12,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPE,12,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPE,12,0:ETP,0:HOTLINK,3:;

Configure ETPSIG-M TCP/IP stack configuration for ETPE (SE-NH).ZQRA:ETPE, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPE, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPE, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M IP address with parameters PDM to BOND0 interface. ZQRN:ETPE,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Create ETPSIG-C IP address ZQRN:ETPE,<pair_number>,>unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSIG-CZD2C:M:BCSU,<unit_index>::ETPE,<pair_number>,<unit_index>:::;ZD2C:C,NOR:BCSU,<unit_index>::ETPE,<pair_umber>,<unit_index>:::;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units

Create EL0 IP address to ETPE ZQRA:ETPE,<pair_number>,<unit_index>::EL0::UP; ZQRN:ETPE,<pair_number>,<unit_index>::EL0,:"<ip_address>",<network_mask_length>,P,:;

Create EEP interface for traffic between ETPE and ETPAZQRA:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Note: EEP interface creation is required only if A over IP is used.

Note: In case of BSC 3i 1000/2000 or Upgraded flexi Single cabinet/Double cabinet the following pop upwill occur in macro.

Page 77: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

77 (270)

Select the required application to proceed further.

Note: Create the PEP link to ETPGID 0 first if you want to get the ETP object ID for the ETPGID to match inNetAct.

Create PEP interface if PCU2-E’s are in useZQRA:ETPE, <pair_number>,<unit_index>::<PEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPE, <pair_number>,<unit_index>::<PEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPE, <pair_number>,<unit_index>::<PEP_VLAN>:"<ip_address>":TAG,"PEP":;

Create IN0 interface( Internal Octeon-DSP interface)ZQRA:ETPE,<pair number>,<unit index>:IN0::UP;ZQRN:ETPE,<pair number>,<unit index>::IN0”<ip address>”,<NETWORK_MASK_LENGTH>,P,I::;

Create static route ZQKC:ETPE, <pair_number>,<unit_index>:::"<Gateway ip address>":PHY:;

Change state of ETPE to TE-EXZUSC:ETPE,<pair_number>,<unit_index>:SE;ZUSC:ETPE,<pair_number>,<unit_index>:TE;

11.1.3 Check Plug-in unit software

Note: The flashing does not succeed if the username and password in the ETP card does not match the BSC’susername & password. Refer Appendix 6 to see an example how to update the username & password via ETPservice terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Check the CBUHAN version in BSC package.ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Page 78: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

78 (270)

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG for ETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG for ETPE.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Page 79: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

79 (270)

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Page 80: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

80 (270)

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

11.1.4 Diagnostic

Run diagnostic to the ETPEZUDU:ETPE,<pair number>,<unit index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPE to WO-EXZUSC:ETPE,<pair number>,<unit index>:WO;

11.1.5 Check PCU configuration

If Packet Abis interface is also used in PS traffic check PCU configuration. PCU2-D or PCU2-E must be created tothe PCUPAB function that it can carry Packet Abis PS data.

For PCU2_E cards PEP interface creation is required to support PEP Eth link. These creations are mentioned inthe below document.

PCU configuration can be checked with following command:ZWTI:BCSU,<unit_index>;

Use “ BSC PCU HW implementation for PS traffic” procedure if PCU configurations need to change.

ETP- PCU connection.

ZESK:ETPE,<pair number>:BCSU,<index>:PCU,<index>:;

Note :This is required for both PCU2_E and PCU2_D cards.

11.2 Creation of ETPE unit with hardware protection

Note!Macro asks in this point Plug-in redundancy type and Unit location. After that macro check possibleunit/PCM overlapping.

If there is overlapping PCM areas move or remove resources from them. Macro will remove unit and Plug-in Units automatically after needed resources are install Plug-in units, terminators and cables

Page 81: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

81 (270)

Note: - Refer Appendix 2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

11.2.1 Install Plug-in units, terminators and cables

11.2.1.1 Terminators and setting modules

For BSC 3i 1000/2000/Upgraded Flexi BSC

For BSC 3i 1000/Upgraded Flexi Single cabinetPosition ID Name FU Cabinet Use Note ETPE

INDEX5.6B 014E

C108719ADMOD00

GTIC 0 BSCC For ETPE 1) ETPE 0-0

5.6B 064E

C108719ADMOD00

GTIC 0 BSCC For ETPE 1) ETPE 1-0

5.9B 014E

C108719ADMOD00

GTIC 1 BSCC For ETPE 1) ETPE 0-1

5.9B 064E

C108719ADMOD00

GTIC 1 BSCC For ETPE 1) ETPE 1-1

5.6B09.2J

C101501 CABID1A GTIC 0 BSCC Cabinetidentification

ETPE 0-0/ETPE 1-0

5.6B09.2L

C101557 CARID53 GTIC 0 BSCC Cartridgeidentification

ETPE 0-0/ ETPE1-0

5.9B09.2J

C101501 CABID1A GTIC 1 BSCC Cabinetidentification

ETPE 0-1/ ETPE1-1

5.9B09.2L

C101558 CARID54 GTIC 1 BSCC Cartridgeidentification

ETPE 0-1/ ETPE1-1

Notes:1) When ETP PIU is used as ETPE in this slot.

For BSC 3i 2000/Upgraded Flexi Double cabinet

Position ID Name FU Cabinet Use NoteETPEINDEX

5.6B 014E C108719 ADMOD00 GTIC 0 BSCC For ETPE 1) ETPE 0-15.6B 064E C108719 ADMOD00 GTIC 0 BSCC For ETPE 1) ETPE 1-15.9B 014E C108719 ADMOD00 GTIC 1 BSCC For ETPE 1) ETPE 0-05.9B 064E C108719 ADMOD00 GTIC 1 BSCC For ETPE 1) ETPE 1-02.0B 014E C108719 ADMOD00 ETC 2 BSCD For ETPE 1) ETPE 2-12.0B 064E C108719 ADMOD00 ETC 2 BSCD For ETPE 1) ETPE 3-02.3B 014E C108719 ADMOD00 ETC 3 BSCD For ETPE 1) ETPE 2-0

2.3B 06 C108719 ETC 3 BSCD For ETPE 1) ETPE 3-1

Page 82: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

82 (270)

4E ADMOD00

2.6B 014E C108719 ADMOD00 ETC 4 BSCD For ETPE 1) ETPE 4-02.6B 064E C108719 ADMOD00 ETC 4 BSCD For ETPE 1) ETPE 5-02.9B 014E C108719 ADMOD00 ETC 5 BSCD For ETPE 1) ETPE 4-12.9B 064E C108719 ADMOD00 ETC 5 BSCD For ETPE 1) ETPE 5-1

5.6B09.2J C101501 CABID1A GTIC 0 BSCC

Cabinetidentification

ETPE 0-1/ ETPE1-1

5.6B09.2L C101557 CARID53 GTIC 0 BSCC

Cartridgeidentification

ETPE 0-1/ ETPE1-1

5.9B09.2J C101501 CABID1A GTIC 1 BSCC

Cabinetidentification

ETPE 0-0/ ETPE1-0

5.9B09.2L C101558 CARID54 GTIC 1 BSCC

Cartridgeidentification

ETPE 0-0/ ETPE1-0

2.0B09.2J C101502 CABID1B ETC 2 BSCD

Cabinetidentification

ETPE 2-1/ ETPE3-0

2.0B09.2L C101535 CARID20 ETC 2 BSCD

Cartridgeidentification

ETPE 2-1/ ETPE3-0

2.3B09.2J C101502 CABID1B ETC 3 BSCD

Cabinetidentification

ETPE 2-0/ ETPE3-1

2.3B09.2L C101536 CARID21 ETC 3 BSCD

Cartridgeidentification

ETPE 2-0/ ETPE3-1

2.6B09.2J C101502 CABID1B ETC 4 BSCD

Cabinetidentification

ETPE 4-0/ ETPE5-0

2.6B09.2L C101538 CARID23 ETC 4 BSCD

Cartridgeidentification

ETPE 4-0/ ETPE5-0

2.9B09.2J C101502 CABID1B ETC 5 BSCD

Cabinetidentification

ETPE 4-1/ ETPE5-1

2.9B09.2L C101539 CARID24 ETC 5 BSCD

Cartridgeidentification

ETPE 4-1/ ETPE5-1

Notes:1) When ETP PIU is used as ETPE in this slot

11.2.1.2 Plug-in unit installation

For BSC 3i 1000/2000/Upgraded Flexi BSC

For BSC 3i 1000/Upgraded Flexi Single cabinetCatridgeSGC1Cposition

Unit Cartridge/ Slots

ETPEgroupindex

Page 83: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

83 (270)

5.6 GTIC-0 1 0-0

5.6 GTIC-0 6 1-0

5.9 GTIC-1 1 0-1

5.9 GTIC-1 6 1-1

Note:Check Appendix 5 for ETP strappings.

For BSC 3i 2000/Upgraded Flexi Double cabinet.CatridgeSGC1Cposition

Unit Cartridge/ Slots

ETPEgroupindex

5.6 GTIC-0 1 0-1

5.6 GTIC-0 6 1-1

Page 84: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

84 (270)

5.9 GTIC-1 1 0-0

5.9 GTIC-1 6 1-02.0 ETC-2 1 2-1

2.0 ETC-2 6 3-0

2.3 ETC-3 1 2-0

2.3 ETC-3 6 3-1

2.6 ETC-4 1 4-0

2.6 ETC-4 6 5-0

2.9 ETC-5 1 4-1

2.9 ETC-5 6 5-1

Note:Check Appendix 5 for ETP strappings.

Page 85: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

85 (270)

.

11.2.1.3 Cabling

11.2.1.3.1 Change MCMU,0,SWU-0,SWU-2,SWU-4,SWU-6 SE-NH state.

ZUSC:MCMU,0:SP; If neededZUSC:MCMU,0:TE;ZUSC:MCMU,0:SE;ZUSC:MCMU,0:SE;

ZUSC:EMB,0:SP; If neededZUSC:EMB,0:TE;ZUSC:EMB,0:SE;ZUSC:EMB,0:SE;

Page 86: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

86 (270)

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

11.2.1.3.1.1 For initial BSC 3i 1000/2000

11.2.1.3.1.1.1 11.2.1.3.1.1.1 For BSC 3i 1000

Remove following cables if neededEquipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 2)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 2)

Notes: 1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2). 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No

OldCab/ Old FU/ Old

Position/OldCab/ Old FU/ Old

Position/Type Use Not

e ETPEindex

NewCab New FU New

PositionNewCab New FU New

Position

BSCC_714 BSCC GTIC 0

5.6F02.SB1-0 BSCC GSW2K

B 0

1.0F02.SB2-0 CSB03

1 2)

ETPE 0-0

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC 0

5.6F02.SB2-0

BSCC GSW2KB 0

1.0F02.SB4-0

CSB030 2)

ETPE 0-0

Page 87: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

87 (270)

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC 15.9F01.SB1-0 BSCC GSW2K

B 0

1.0F06.SB2-0 CSB02

7 1)

ETPE 1-0GTIC 0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC 15.9F01.SB2-0 BSCC GSW2K

B 0

1.0F07.SB2-0 CSB02

7 1)

ETPE 1-0GTIC 0

5.6F07.SB3-0

1.0F08.SB1-1

BSCC_730 BSCC GTIC 1

5.9F02.SB1-0 BSCC GSW2K

B 0

1.0F07.SB3-0 CSB02

7 1)

ETPE 1-1

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCC GTIC 1

5.9F02.SB2-0 BSCC GSW2K

B 0

1.0F07.SB4-0 CSB02

7 1)

ETPE 1-1

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2K

B 0

1.0F01.SB2-0 CSB03

1 2)

ETPE 0-1GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC 05.6F01.SB2-0 BSCC GSW2K

B 0

1.0F01.SB4-0 CSB03

0 2)

ETPE 0-1GTIC 1

5.9F02.SB3-0

1.0F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Add needed ETPLAN cables from LANU-0 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use ETPindex

BSCC_4400 LANU 0 5.0B05.2E GTIC 0 5.6B

06.4G CHES009 ETPLAN ETPE1-0

BSCC_4402 LANU 0 5.0B05.2J GTIC 0 5.6B

01.4G CHES008 ETPLAN ETPE0-0

BSCC_4403 LANU 0 5.0B05.2L GTIC 1 5.9B

06.4G CHES011 ETPLAN ETPE1-1

Page 88: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

88 (270)

BSCC_4405 LANU 0 5.0B05.2P GTIC 1 5.9B

01.4G CHES010 ETPLAN ETPE0-1

Page 89: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

89 (270)

11.2.1.3.1.1.2 For BSC 3i 2000

Remove following cables if needed

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_718 GTIC 05.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 2)

BSCC_719 GTIC 05.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 2)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 3)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 3)

BSCC_734 GTIC 15.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 4)

BSCC_735 GTIC 15.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 4)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add following cables if requiredEquipping Cable from Cable to

No

OldCab/

OldFU/

OldPosition/

OldCab/ Old FU/

OldPosition/ Type Us

eNote ETPE

IndexNewCab

NewFU

NewPosition

NewCab New FU New

Position

BSCC_730

BSCC

GTIC 1

5.9F02.SB1-0 BSC

CGSW2KB 0

1.0F07.SB3-0 CSB02

7 1) ETPE 1-05.9F07.SB2-0

1.0F08.SB2-0

BSCC_731

BSCC

GTIC 1

5.9F02.SB2-0 BSC

CGSW2KB 0

1.0F07.SB4-0 CSB02

7 1) ETPE 1-05.9F07.SB3-0

1.0F08.SB1-0

Page 90: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

90 (270)

BSCC_710

BSCC

GTIC 0

5.6F01.SB1-0 BSC

CGSW2KB 0

1.0F01.SB2-0 CSB03

1 2) ETPE 0-0GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711

BSCC

GTIC 0

5.6F01.SB2-0 BSC

CGSW2KB 0

1.0F01.SB4-0 CSB03

0 2) ETPE 0-0GTIC 1

5.9F02.SB3-0

1.0F02.SB4-0

BSCC_714

BSCC

GTIC 0

5.6F02.SB1-0 BSC

CGSW2KB 0

1.0F02.SB2-0 CSB03

1 2) ETPE 0-15.6F02.SB2-0

1.0F02.SB2-1

BSCC_715

BSCC

GTIC 0

5.6F02.SB2-0 BSC

CGSW2KB 0

1.0F02.SB4-0 CSB03

0 2) ETPE 0-15.6F02.SB3-0

1.0F02.SB4-1

BSCC_726

BSCC

GTIC 1

5.9F01.SB1-0 BSC

CGSW2KB 0

1.0F06.SB2-0 CSB02

7 1) ETPE 1-1GTIC 0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727

BSCC

GTIC 1

5.9F01.SB2-0 BSC

CGSW2KB 0

1.0F07.SB2-0 CSB02

7 1) ETPE 1-1GTIC 0

5.6F07.SB3-0

1.0F08.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Equipping Cable from Cable to

No Old Old FU OldPosition

New FU NewPosition

Old OldFU

OldPosition

Type Use Note

ETPEIndex

Cab Cab

BSCC_4372

BSCC

GSW2KB 0

1.0F02.SB4-0

GSW2KB 0

1.0F07.SB4-1

BSCD

ETC 3

2.3F07.SB3-0

CSB024

Hotlink

ETPE3-1

BSCC_4360

BSCC

GSW2KB 0

1.0F02.SB2-0

GSW2KB 0

1.0F07.SB3-1

BSCD

ETC 3

2.3F07.SB2-0

CSB027

Hotlink

3) ETPE3-1

BSCC_4356

BSCC

GSW2KB 0

1.0F07.SB2-0

GSW2KB 0

1.0F05.SB2-1

BSCD

ETC 5

2.9F07.SB2-0

CSB029

Hotlink

1) ETPE5-1

BSCC_4368

BSCC

GSW2KB 0

1.0F06.SB2

GSW2KB 0

1.0F05.SB4

BSCD

ETC 5

2.9F 07SB3-0

CSB029

Hotlink

1) ETPE5-1

Page 91: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

91 (270)

-0 -1

BSCC_4358

BSCC

GSW2KB 0

1.0F08.SB2-0

GSW2KB 0

1.0F01.SB2-1

BSCD

ETC 5

2.9F02.SB2-0

CSB027

Hotlink

2) ETPE4-1

BSCC_4370

BSCC

GSW2KB 0

1.0F08.SB1-0

GSW2KB 0

1.0F01.SB4-1

BSCD

ETC 5

2.9F02.SB3-0

CSB029

Hotlink

2) ETPE4-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-0 to required tracks, Hotlinks from GSW,0 to required tracksEquipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use Note ETPEIndex

BSCC_4300 LANU0

5.0B05.1A BSCC ETC 2 2.0B

01.4G BSCD CHES045 ETPLAN ETPE 2-1

BSCC_4302 LANU0

5.0B05.1E BSCC ETC 2 2.0B

06.4G BSCD CHES044 ETPLAN ETPE 3-0

BSCC_4303 LANU0

5.0B05.1G BSCC ETC 3 2.3B

01.4G BSCD CHES043 ETPLAN ETPE 2-0

BSCC_4305 LANU0

5.0B05.1L BSCC ETC 3 2.3B

06.4G BSCD CHES042 ETPLAN ETPE 3-1

BSCC_4306 LANU0

5.0B05.1N BSCC ETC 4 2.6B

01.4G BSCD CHES042 ETPLAN ETPE 4-0

BSCC_4307 LANU0

5.0B05.1P BSCC ETC 4 2.6B

06.4G BSCD CHES041 ETPLAN ETPE 5-0

BSCC_4308 LANU0

5.0B05.1R BSCC ETC 5 2.9B

01.4G BSCD CHES041 ETPLAN ETPE 4-1

BSCC_4309 LANU0

5.0B05.2C BSCC ETC 5 2.9B

06.4G BSCD CHES040 ETPLAN ETPE 5-1

BSCD_4350ETC4

2.6F07.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB027 Hotlink 1) ETPE 5-0

BSCD_4352 ETC4

2.6F02.SB2-0

BSCD GSW2KB0

1.0F01.SB2-0

BSCC CSB027 Hotlink 1) ETPE 4-0

BSCD_4362 ETC4

2.6F07.SB3-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB027 Hotlink 1), 2) ETPE 5-0

BSCD_4364 ETC4

2.6F02.SB3-0

BSCD GSW2KB0

1.0F01.SB4-0

BSCC CSB027 Hotlink 1), 2) ETPE 4-0

BSCD_4354 ETC2

2.0F07.SB2-0

BSCD GSW2KB0

1.0F07.SB3-0

BSCC CSB022 Hotlink 1) ETPE 3-0

BSCD_4366 ETC2

2.0F07.SB3-0

BSCD GSW2KB0

1.0F07.SB4-0

BSCC CSB021 Hotlink 1), 2) ETPE 3-0

Page 92: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

92 (270)

BSCD_4620 ETC3

2.3F02.SB2-0 BSCD GSW2KB

0

1.0F07.SB2-0

BSCC CSB026 Hotlink 3)Default

ETPE 2-0

BSCD_4624 ETC3

2.3F02.SB3-0 BSCD GSW2KB

0

1.0F06.SB2-0

BSCC CSB026 Hotlink 3) ETPE 2-0

BSCD_4622 ETC2

2.0F02.SB2-0 BSCD GSW2KB

0

1.0F07.SB2-1

BSCC CSB026 Hotlink 3) ETPE 2-1

BSCD_4626 ETC2

2.0F02.SB3-0 BSCD GSW2KB

0

1.0F06.SB2-1

BSCC CSB026 Hotlink 3) ETPE 2-1

BSCC_4400 LANU0

5.0B05.2E BSCC GTIC 0 5.6B

06.4G BSCC CHES009 ETPLAN ETPE 1-1

BSCC_4402 LANU0

5.0B05.2J BSCC GTIC 0 5.6B

01.4G BSCC CHES008 ETPLAN ETPE 0-1

BSCC_4403 LANU0

5.0B05.2L BSCC GTIC 1 5.9B

06.4G BSCC CHES011 ETPLAN ETPE 1-0

BSCC_4405 LANU0

5.0B05.2P BSCC GTIC 1 5.9B

01.4G BSCC CHES010 ETPLAN ETPE 0-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))2) These cables are not used, if no PCU2-D is equipped3) These Hotlink cables are added in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot01/02 is taken in use.

11.2.1.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet11.2.1.3.1.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if needed.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 0 5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 0 5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_730 GTIC 1 5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 2)

BSCC_731 GTIC 1 5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 2)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1 (and 2). 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Note: The hotlink connections from GSW to ETPE cards are not required if PS via PCU2_E( ie PEP link) and Ainterface over IP is used.

Page 93: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

93 (270)

Move and reconnect or add following cables if required.Equipping Cable from Cable to

No

OldCab/ Old FU/ Old

Position/OldCab/ Old FU/ Old

Position/ Type Use NoteETPEindex

NewCab New FU New

PositionNewCab New FU New

Position

BSCC_714 BSCC GTIC 0

5.6F02.SB1-0 BSCC GSW2KB

0

1.0F02.SB2-0 CSB03

1 2)

ETPE 0-0

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC 0

5.6F02.SB2-0 BSCC GSW2KB

0

1.0F02.SB4-0 CSB03

0 2)

ETPE 0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC 15.9F01.SB1-0 BSCC GSW2KB

0

1.0F06.SB2-0 CSB02

7 1)

ETPE 1-0

GTIC 05.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC 15.9F01.SB2-0 BSCC GSW2KB

0

1.0F07.SB2-0 CSB02

7 1)

ETPE 1-0

GTIC 05.6F07.SB3-0

1.0F08.SB1-1

BSCC_730 BSCC GTIC 1

5.9F02.SB1-0 BSCC GSW2KB

0

1.0F07.SB3-0 CSB02

7 1)

ETPE 1-1

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCC GTIC 1

5.9F02.SB2-0 BSCC GSW2KB

0

1.0F07.SB4-0 CSB02

7 1)

ETPE 1-1

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2KB

0

1.0F01.SB2-0 CSB03

1 2)

ETPE 0-1

GTIC 15.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC 05.6F01.SB2-0 BSCC GSW2KB

0

1.0F01.SB4-0 CSB03

0 2)

ETPE 0-1

GTIC 15.9F02.SB3-0

1.0F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.

Page 94: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

94 (270)

2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Add needed ETPLAN cables from LANU-0 to required tracks.

Equipping CABLE FROM CABLE TOETPEINDEXNo FU Position FU Position Type Use Note

BSCC_4400 LANU 0 1.8B05.2G GTIC 0 5.6B

06.4G CHES023 ETPLAN ETPE 1-0

BSCC_4402 LANU 0 1.8B05.2L GTIC 0 5.6B

01.4G CHES024 ETPLAN ETPE 0-0

BSCC_4403 LANU 0 1.8B05.2N GTIC 1 5.9B

06.4G CHES021 ETPLAN ETPE 1-1

BSCC_4405 LANU 0 1.8B05.2R GTIC 1 5.9B

01.4G CHES022 ETPLAN ETPE 0-1

11.2.1.3.1.2.2 For upgraded flexi BSC Double cabinet.

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_714 GTIC 05.6F02.SB1-0

GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

BSCC_715 GTIC 05.6F02.SB2-0

GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

BSCC_718 GTIC 05.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 3)

BSCC_719 GTIC 05.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 3)

BSCC_726 GTIC 15.9F01.SB1-0

GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 4)

BSCC_727 GTIC 15.9F01.SB2-0

GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 4)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 5)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 5)

BSCC_734 GTIC 15.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 6)

Page 95: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

95 (270)

BSCC_735 GTIC 15.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No

OldCab/

OldFU/

OldPosition/

OldCab/ Old FU/

OldPosition/

Type Use NoteETPEIndex

NewCab

NewFU

NewPosition

NewCab New FU

NewPosition

BSCC_730 BSCCGTIC1

5.9F02.SB1-0

BSCCGSW2KB0

1.0F07.SB3-0

CSB027 1)ETPE 1-0

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCCGTIC1

5.9F02.SB2-0

BSCCGSW2KB0

1.0F07.SB4-0

CSB027 1)ETPE 1-0

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC0

5.6F01.SB1-0

BSCCGSW2KB0

1.0F01.SB2-0

CSB031 2)ETPE 0-0

GTIC1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC0

5.6F01.SB2-0

BSCCGSW2KB0

1.0F01.SB4-0

CSB030 2)ETPE 0-0

GTIC1

5.9F02.SB3-0

1.0F02.SB4-0

BSCC_714 BSCCGTIC0

5.6F02.SB1-0

BSCCGSW2KB0

1.0F02.SB2-0

CSB031 2)ETPE 0-1

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCCGTIC0

5.6F02.SB2-0

BSCCGSW2KB0

1.0F02.SB4-0

CSB030 2)ETPE 0-1

5.6F02.SB3-

1.0F02.SB4-

Page 96: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

96 (270)

0 1

BSCC_726 BSCC

GTIC1

5.9F01.SB1-0

BSCCGSW2KB0

1.0F06.SB2-0

CSB027 1)ETPE 1-1

GTIC0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC1

5.9F01.SB2-0

BSCCGSW2KB0

1.0F07.SB2-0

CSB027 1)ETPE 1-1

GTIC0

5.6F07.SB3-0

1.0F08.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Equipping Cable from Cable to

No Old Old FU OldPosition

NewFU

NewPosition

OLd OldFU

OldPosition

Type Use Note

ETPEIndexCab Cab

BSCC_4372

BSCC

GSW2KB 0

1.0F02.SB4-0

GSW2KB 0

1.0F07.SB4-1

BSCD ETC3

2.3F07.SB3-0

CSB024

Hotlink

ETPE3-1

BSCC_4360

BSCC

GSW2KB 0

1.0F02.SB2-0

GSW2KB 0

1.0F07.SB3-1

BSCD ETC3

2.3F07.SB2-0

CSB027

Hotlink

3) ETPE3-1

BSCC_4356

BSCC

GSW2KB 0

1.0F07.SB2-0

GSW2KB 0

1.0F05.SB2-1

BSCD ETC5

2.9F07.SB2-0

CSB029

Hotlink

1) ETPE5-1

BSCC_4368

BSCC

GSW2KB 0

1.0F06.SB2-0

GSW2KB 0

1.0F05.SB4-1

BSCD ETC5

2.9F 07SB3-0

CSB029

Hotlink

1)4)

ETPE5-1

BSCC_4358

BSCC

GSW2KB 0

1.0F08.SB2-0

GSW2KB 0

1.0F01.SB2-1

BSCD ETC5

2.9F02.SB2-0

CSB027

Hotlink

2) ETPE4-1

BSCC_4370

BSCC

GSW2KB 0

1.0F08.SB1-0

GSW2KB 0

1.0F01.SB4-1

BSCD ETC5

2.9F02.SB3-0

CSB029

Hotlink

2)4)

ETPE4-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.4) These cables are used only if ETP(T) or ETP(E) HW is used together with PCU2-D.

Page 97: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

97 (270)

Added ETPLAN from LANU-0 to required tracks, Hotlinks from GSW,0 to required tracks

Equipping CABLE FROM CABLE TO

No FU PositionCabinet FU

Position

Cabinet Type Use Note

ETPEIndex

BSCC_4300

LANU 0

1.8B05.1C

BSCC ETC 2 2.0B01.4G

BSCD CHES020

ETPLAN

ETPE2-1

BSCC_4302

LANU 0

1.8B05.1G

BSCC ETC 2 2.0B06.4G

BSCD CHES021

ETPLAN

ETPE3-0

BSCC_4303

LANU 0

1.8B05.1J

BSCC ETC 3 2.3B01.4G

BSCD CHES023

ETPLAN

ETPE2-0

BSCC_4305

LANU 0

1.8B05.1N

BSCC ETC 3 2.3B06.4G

BSCD CHES024

ETPLAN

ETPE3-1

BSCC_4306

LANU 0

1.8B05.1P

BSCC ETC 4 2.6B01.4G

BSCD CHES026

ETPLAN

ETPE4-0

BSCC_4307

LANU 0

1.8B05.1R

BSCC ETC 4 2.6B06.4G

BSCD CHES027

ETPLAN

ETPE5-0

BSCC_4308

LANU 0

1.8B05.2C

BSCC ETC 5 2.9B01.4G

BSCD CHES028

ETPLAN

ETPE4-1

BSCC_4309

LANU 0

1.8B05.2E

BSCC ETC 5 2.9B06.4G

BSCD CHES029

ETPLAN

ETPE5-1

BSCD_4350

ETC4

2.6F07.SB2-0

BSCD GSW2KB 0

1.0F05.SB2-0

BSCC CSB027 HotlinkETPE5-0

BSCD_4352

ETC4

2.6F02.SB2-0 BSCD

GSW2KB 0

1.0F01.SB2-0 BSCC CSB027 Hotlink 1)

ETPE4-0

BSCD_4362

ETC4

2.6F07.SB3-0 BSCD

GSW2KB 0

1.0F05.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPE5-0

BSCD_4364

ETC4

2.6F02.SB3-0 BSCD

GSW2KB 0

1.0F01.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPE4-0

BSCD_4354

ETC2

2.0F07.SB2-0 BSCD

GSW2KB 0

1.0F07.SB3-0 BSCC CSB022 Hotlink 1)

ETPE3-0

BSCD_4366

ETC2

2.0F07.SB3-0 BSCD

GSW2KB 0

1.0F07.SB4-0 BSCC CSB021 Hotlink 1), 2)

ETPE3-0

BSCD_4620

ETC3

2.3F02.SB2-0 BSCD

GSW2KB 0

1.0F07.SB2-0 BSCC CSB026 Hotlink

3)Default

ETPE2-0

BSCD_4624

ETC3

2.3F02.SB3-0 BSCD

GSW2KB 0

1.0F06.SB2-0 BSCC CSB026 Hotlink 3)

ETPE2-0

BSCD_4622

ETC2

2.0F02.SB2-0 BSCD

GSW2KB 0

1.0F07.SB2-1 BSCC CSB026 Hotlink 3)

ETPE2-1

BSCD_4626

ETC2

2.0F02.SB3-0 BSCD

GSW2KB 0

1.0F06.SB2-1 BSCC CSB026 Hotlink 3)

ETPE2-1

BSCC_4400

LANU 0

1.8B05.2G BSCC

GTIC 0 5.6B06.4G BSCC

CHES023

ETPLAN

ETPE1-1

BSCC_4402

LANU 0

1.8B05.2L BSCC

GTIC 0 5.6B01.4G BSCC

CHES024

ETPLAN

ETPE0-1

Page 98: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

98 (270)

BSCC_4403

LANU 0

1.8B05.2N

GTIC 1 5.9B06.4G

CHES021

ETPLAN

ETPE1-0

BSCC_4405

LANU 0

1.8B05.2R

GTIC 1 5.9B01.4G

CHES022

ETPLAN

ETPE0-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))2) These cables are not used, if no PCU2-D is equipped3) These Hotlink cables are added in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot01/02 is taken in use.

Check SW256B dip switching. See appendix 1

11.2.1.3.2 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:MCMU,0:SE;ZUSC:MCMU,0:TE;ZUSC:MCMU,0:SP;ZUSC:MCMU,0:WO;

ZUSC:EMB,0:SE;ZUSC:EMB,0:TE;ZUSC:EMB,0:SP;ZUSC:EMB,0:WO;

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;

11.2.1.3.3 Change MCMU-1, SWU-1, SWU-3, SWU-5 and SWU-7 SE-NH state

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SE;ZUSC:MCMU,1:SE;

ZUSC:EMB,1:TE;ZUSC:EMB,1:SE;ZUSC:EMB,1:SE;

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;ZUSC:SWU,3:SE;

Page 99: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

99 (270)

ZUSC:SWU,5:TE;ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

11.2.1.3.3.1 For initial BSC 3i 1000/2000

11.2.1.3.3.1.1 For BSC 3i 1000

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 2)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 2)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Move and reconnect or add cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716 BSCC GTIC 0 5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2)

ETPE 0-0

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717 BSCC GTIC 0 5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

ETPE 0-0

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1)

ETPE 1-0

GTIC 0 5.6F07.SB2-1

1.3F08.SB2-1

Page 100: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

100 (270)

BSCC_729 BSCC GTIC 1 5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1)

ETPE 1-0

GTIC 0 5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732 BSCC GTIC 1 5.9F02.SB1-1

BSCC GSW2KB1

1.3F07.SB3-0

CSB025 1)

ETPE 1-1

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733 BSCC GTIC 1 5.9F02.SB2-1

BSCC GSW2KB1

1.3F07.SB4-0

CSB025 1)

ETPE 1-1

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712 BSCC GTIC 0 5.6F01.SB1-1

BSCC GSW2KB1

1.3F01.SB2-0

CSB029 2)

ETPE 0-1

GTIC 1 5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713 BSCC GTIC 0 5.6F01.SB2-1

BSCC GSW2KB1

1.3F01.SB4-0

CSB028 2)

ETPE 0-1

GTIC 1 5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Add needed 2N and ETPLAN cables from LANU-1 to required tracks

Equipping CABLE FROM CABLE TO

ETPE INDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU 1 5.2B05.2E

GTIC 0 5.6B06.4J

CHES008 ETPLANETPE 1-0

BSCC_4408 LANU 1 5.2B05.2J

GTIC 0 5.6B01.4J

CHES007 ETPLANETPE 0-0

BSCC_4409 LANU 1 5.2B05.2L

GTIC 1 5.9B06.4J

CHES010 ETPLANETPE 1-1

BSCC_4411 LANU 1 5.2B05.2P

GTIC 1 5.9B01.4J

CHES009 ETPLANETPE 0-1

BSCC_1242 GTIC 15.9B02.4A GTIC 0

5.6B02.4A CHFX006 2N

1) ETPE 0-1/ETPE 0-0

BSCC_1252 GTIC 15.9B07.4A GTIC 0

5.6B07.4A CHFX006 2N

1) ETPE 1-1/ETPE 1-0

Notes:1) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready

for connecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s)

Page 101: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

101 (270)

11.2.1.3.3.1.2 For BSC 3i 2000 .

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_720 GTIC 0 5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 2)

BSCC_721 GTIC 0 5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 2)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 3)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 3)

BSCC_736 GTIC 1 5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 4)

BSCC_737 GTIC 1 5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 4)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add cables if required

Equipping Cable from Cable to

No OldCab/

Old FU/ OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716 BSCC GTIC 0 5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2)

ETPE 0-1

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717 BSCC GTIC 0 5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

ETPE 0-1

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1) ETPE 1-1

Page 102: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

102 (270)

GTIC 0 5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729 BSCC GTIC 1 5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1)

ETPE 1-1

GTIC 0 5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732 BSCC GTIC 1 5.9F02.SB1-1

BSCC GSW2KB1

1.3F07.SB3-0

CSB025 1)

ETPE 1-0

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733 BSCC GTIC 1 5.9F02.SB2-1

BSCC GSW2KB1

1.3F07.SB4-0

CSB025 1)

ETPE 1-0

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712 BSCC GTIC 0 5.6F01.SB1-1

BSCC GSW2KB1

1.3F01.SB2-0

CSB029 2)

ETPE 0-0

GTIC 1 5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713 BSCC GTIC 0 5.6F01.SB2-1

BSCC GSW2KB1

1.3F01.SB4-0

CSB028 2)

ETPE 0-0

GTIC 1 5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot01/02 is taken in use.

Equipping Cable from Cable to

No Old OldFU

OldPosition

NewFU

NewPosition

OLD OldFU

OldPosition

Type Use Note

ETPEINDEX

Cab Cab

BSCC_4373

BSCC GSW2KB 1

1.3F02.SB4-0

GSW2KB 1

1.3F07.SB4-1

BSCD

ETC3

2.3F07.SB3-1

CSB022

Hotlink ETPE

3-1BSCC_4361

BSCC GSW2KB 1

1.3F02.SB2-0

GSW2KB 1

1.3F07.SB3-1

BSCD

ETC3

2.3F07.SB2-1

CSB025

Hotlink

3)ETPE3-1

BSCC_4357

BSCC GSW2KB 1

1.3F07.SB2-0

GSW2KB 1

1.3F05.SB2-1

BSCD

ETC5

2.9F07.SB2-1

CSB027

Hotlink

1)ETPE5-1

BSCC_4369

BSCC GSW2KB 1

1.3F06.SB2-0

GSW2KB 1

1.3F05.SB4-1

BSCD

ETC5

2.9F07.SB3-1

CSB027

Hotlink

1)ETPE5-1

BSCC_4359

BSCC GSW2KB 1

1.3F08.SB2-0

GSW2KB 1

1.3F01.SB2-1

BSCD

ETC5

2.9F02.SB2-1

CSB026

Hotlink

2)ETPE4-1

BSCC_4371

BSCC GSW2KB 1

1.3F08.SB1-0

GSW2KB 1

1.3F01.SB4-1

BSCD

ETC5

2.9F02.SB3-1

CSB027

Hotlink

2)ETPE4-1

Page 103: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

103 (270)

3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Add ETPLAN from LANU-1 to required tracks, Hotlinks from GSW,1 to required tracks

Equipping CABLE FROM CABLE TOETPEINDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU 1 5.2B05.2E

GTIC 0 5.6B06.4J

CHES008 ETPLANETPE 1-1

BSCC_4408 LANU 1 5.2B05.2J

GTIC 0 5.6B01.4J

CHES007 ETPLANETPE 0-1

BSCC_4409 LANU 1 5.2B05.2L

GTIC 1 5.9B06.4J

CHES010 ETPLANETPE 1-0

BSCC_4411 LANU 1 5.2B05.2P

GTIC 1 5.9B01.4J

CHES009 ETPLANETPE 0-0

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FUPosition

Cabinet Type Use Note ETPEINDEX

BSCC_4310 LANU1

5.2B05.1A

BSCC ETC 2 2.0B01.4J

BSCD CHES043 ETPLANETPE2-1

BSCC_4312 LANU1

5.2B05.1E

BSCC ETC 2 2.0B06.4J

BSCD CHES042 ETPLANETPE3-0

BSCC_4313 LANU1

5.2B05.1G

BSCC ETC 3 2.3B01.4J

BSCD CHES041 ETPLANETPE2-0

BSCC_4315 LANU1

5.2B05.1L

BSCC ETC 3 2.3B06.4J

BSCD CHES040 ETPLANETPE3-1

BSCC_4316 LANU1

5.2B05.1N

BSCC ETC 4 2.6B01.4J

BSCD CHES040 ETPLANETPE4-0

BSCC_4317 LANU1

5.2B05.1P

BSCC ETC 4 2.6B06.4J

BSCD CHES039 ETPLANETPE5-0

BSCC_4318 LANU1

5.2B05.1R

BSCC ETC 5 2.9B01.4J

BSCD CHES039 ETPLANETPE4-1

BSCC_4319 LANU1

5.2B05.2C

BSCC ETC 5 2.9B06.4J

BSCD CHES038 ETPLANETPE5-1

BSCD_4351 ETC4

2.6F07.SB2-1

BSCD GSW2KB1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPE5-0

BSCD_4363 ETC4

2.6F07.SB3-1

BSCD GSW2KB1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1), 2)ETPE5-0

BSCD_4365 ETC4

2.6F02.SB3-1

BSCD GSW2KB1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1), 2)ETPE4-0

BSCD_4353 ETC4

2.6F02.SB2-1

BSCD GSW2KB1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPE4-0

Page 104: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

104 (270)

BSCD_4355 ETC2

2.0F07.SB2-1

BSCD GSW2KB1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPE3-0

BSCD_4367 ETC2

2.0F07.SB3-1

BSCD GSW2KB1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1), 2)ETPE3-0

BSCD_4625 ETC3

2.3F02.SB3-1

BSCD GSW2KB1

1.3F06.SB2-0

BSCC CSB023

Hotlink 3) 4)ETPE2-0

BSCD_4621 ETC3

2.3F02.SB2-1

BSCD GSW2KB1

1.3F07.SB2-0

BSCC CSB023

Hotlink3)Default

ETPE2-0

BSCD_4623 ETC2

2.0F02.SB2-1

BSCD GSW2KB1

1.3F07.SB2-1

BSCC CSB023

Hotlink 3)ETPE2-1

BSCD_4627 ETC2

2.0F02.SB3-1

BSCD GSW2KB1

1.3F06.SB2-1

BSCC CSB023

Hotlink 3) 4)ETPE2-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s)) 2) These cables are not used, if no PCU2-D is equipped 3) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by redundancy pair,the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to be connected iftransmission redundancy is upgraded to HW redundancy. 4) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02 istaken in use.

Add needed 2N Redundancy cables.

Equipping Cable from Cable to

ETPEINDEX

No Cabinet FU Position Cabinet FU Position Type Use Note

BSCC_1242 BSCC GTIC1

5.9B02.4A

BSCC GTIC0

5.6B02.4A

CHFX006 2N ETPE0-0 /ETPE0-1

BSCC_1252 BSCC GTIC1

5.9B07.4A

BSCC GTIC0

5.6B07.4A

CHFX006 2N ETPE1-0 /ETPE1-1

BSCD_4454 BSCD ETC5

2.9B07.4A

BSCD ETC4

2.6B07.4A

CHFX006 2N 1) 2) ETPE5-1 /ETPE5-0

BSCD_4455 BSCD ETC5

2.9B02.4A

BSCD ETC4

2.6B02.4A

CHFX006 2N 1) 2) ETPE4-1 /ETPE4-0

BSCD_4456 BSCD ETC2

2.0B07.4A

BSCD ETC3

2.3B07.4A

CHFX006 2N 1) 2) ETPE3-1 /ETPE3-0

Page 105: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

105 (270)

BSCD_4457 BSCD ETC2

2.0B02.4A

BSCD ETC3

2.3B02.4A

CHFX006 2N 1) 2) ETPE2-1 /ETPE2-0

Notes:1) These cables are not included in parts list2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by redundancy pair,the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to be connected iftransmission redundancy is upgraded to HW redundancy.

11.2.1.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet

11.2.1.3.3.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if needed.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC0

5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC0

5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_732 GTIC1

5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 2)

BSCC_733 GTIC1

5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 2)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2). 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Note: The hotlink connections from GSW to ETPE cards are not required if PS via PCU2_E ( ie PEP link)and A interface over IP is used.

Move and reconnect or add cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716 BSCC GTIC 0 5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2)

ETPE 0-0

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717 BSCC GTIC 0 5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

ETPE 0-0

5.6F02.SB3-1

1.3F02.SB4-1

Page 106: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

106 (270)

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1)

ETPE 1-0

GTIC 0 5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729 BSCC GTIC 1 5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1)

ETPE 1-0

GTIC 0 5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732 BSCC GTIC 1 5.9F02.SB1-1

BSCC GSW2KB1

1.3F07.SB3-0

CSB025 1)

ETPE 1-1

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733 BSCC GTIC 1 5.9F02.SB2-1

BSCC GSW2KB1

1.3F07.SB4-0

CSB025 1)

ETPE 1-1

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712 BSCC GTIC 0 5.6F01.SB1-1

BSCC GSW2KB1

1.3F01.SB2-0

CSB029 2)

ETPE 0-1

GTIC 1 5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713 BSCC GTIC 0 5.6F01.SB2-1

BSCC GSW2KB1

1.3F01.SB4-0

CSB028 2)

ETPE 0-1

GTIC 1 5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Add following ETPLAN cables, 2N cables if required.

Equipping CABLE FROM CABLE TOETPEINDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU 1 1.10B05.2G

GTIC 0 5.6B06.4J

CHES022 ETPLAN ETPE 1-0

BSCC_4408 LANU 1 1.10B05.2L

GTIC 0 5.6B01.4J

CHES023 ETPLAN ETPE 0-0

BSCC_4409 LANU 1 1.10B05.2N

GTIC 1 5.9B06.4J

CHES020 ETPLAN ETPE 1-1

BSCC_4411 LANU 1 1.10B05.2R

GTIC 1 5.9B01.4J

CHES021 ETPLAN ETPE 0-1

Page 107: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

107 (270)

BSCC_1242 GTIC 1 5.9B02.4A

GTIC 0 5.6B02.4A

CHFX006 2N 1) ETPE 0-1/ ETPE0-0

BSCC_1252 GTIC 1 5.9B07.4A

GTIC 0 5.6B07.4A

CHFX006 2N 1) ETPE 1-1/ ETPE1-0

Notes:1) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready

for connecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s)

11.2.1.3.3.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC0

5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC0

5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_716 GTIC0

5.6F02.SB1-1

GSW2KB1

1.3F02.SB2-0

CSB029 Hotlink 2)

BSCC_717 GTIC0

5.6F02.SB2-1

GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

BSCC_720 GTIC0

5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 3)

BSCC_721 GTIC0

5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 3)

BSCC_728 GTIC1

5.9F01.SB1-1

GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 4)

BSCC_729 GTIC1

5.9F01.SB2-1

GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 4)

BSCC_732 GTIC1

5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 5)

BSCC_733 GTIC1

5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 5)

BSCC_736 GTIC1

5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 6)

BSCC_737 GTIC1

5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)

Page 108: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

108 (270)

3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add cables if required

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note ETPEINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716

BSCC

GTIC0

5.6F02.SB1-1

BSCC

GSW2KB 1

1.3F03.SB2-0

CSB029

Hotlink

2)

ETPE 0-1

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717

BSCC

GTIC0

5.6F02.SB2-1

BSCC

GSW2KB 1

1.3F02.SB4-0

CSB028

Hotlink

2)

ETPE 0-1

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728

BSCC

GTIC1

5.9F01.SB1-1

BSCC

GSW2KB 1

1.3F06.SB2-0

CSB025

Hotlink

1)

ETPE 1-1

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729

BSCC

GTIC1

5.9F01.SB2-1

BSCC

GSW2KB 1

1.3F07.SB2-0

CSB025

Hotlink

1)

ETPE 1-1

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732

BSCC

GTIC1

5.9F02.SB1-1

BSCC

GSW2KB 1

1.3F07.SB3-0

CSB025

1)

ETPE 1-0

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733

BSCC

GTIC1

5.9F02.SB2-1

BSCC

GSW2KB 1

1.3F07.SB4-0

CSB025

1)

ETPE 1-0

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712

BSCC

GTIC0

5.6F01.SB1-1

BSCC

GSW2KB 1

1.3F01.SB2-0

CSB029

2)

ETPE 0-0

GTIC1

5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713

BSCC

GTIC0

5.6F01.SB2-

BSCC

GSW2KB 1

1.3F01.SB4-

CSB028

2) ETPE 0-0

Page 109: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

109 (270)

1 0

GTIC1

5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot01/02 is taken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-1 to required tracks, Hotlinks from GSW,1 to required tracks

Equipping CABLE FROM CABLE TO

ETPEINDEX

No FU Position FU Position Type Use Note

BSCC_4406 LANU1

5.2B05.2E

GTIC0

5.6B06.4J

CHES008 ETPLANETPE 1-1

BSCC_4408 LANU1

5.2B05.2J

GTIC0

5.6B01.4J

CHES007 ETPLANETPE 0-1

BSCC_4409 LANU1

5.2B05.2L

GTIC1

5.9B06.4J

CHES010 ETPLANETPE 1-0

Equipping Cable from Cable to

No OldCab

Old FU OldPosition

New FU NewPosition

OldCab

OldFU

OldPosition

Type Use Note ETPEINDEX

BSCC_4373

BSCC

GSW2KB 1

1.3F02.SB4-0

GSW2KB 1

1.3F07.SB4-1

BSCD

ETC 3

2.3F07.SB3-1

CSB022 Hotlink ETPE

3-1BSCC_4361

BSCC

GSW2KB 1

1.3F02.SB2-0

GSW2KB 1

1.3F07.SB3-1

BSCD

ETC 3

2.3F07.SB2-1

CSB025 Hotlink

3)ETPE3-1

BSCC_4357

BSCC

GSW2KB 1

1.3F07.SB2-0

GSW2KB 1

1.3F05.SB2-1

BSCD

ETC 5

2.9F07.SB2-1

CSB027 Hotlink

1)ETPE5-1

BSCC_4369

BSCC

GSW2KB 1

1.3F06.SB2-0

GSW2KB 1

1.3F05.SB4-1

BSCD

ETC 5

2.9F07.SB3-1

CSB027 Hotlink

1)ETPE5-1

BSCC_4359

BSCC

GSW2KB 1

1.3F08.SB2-0

GSW2KB 1

1.3F01.SB2-1

BSCD

ETC 5

2.9F02.SB2-1

CSB026 Hotlink

2)ETPE4-1

BSCC_4371

BSCC

GSW2KB 1

1.3F08.SB1-0

GSW2KB 1

1.3F01.SB4-1

BSCD

ETC 5

2.9F02.SB3-1

CSB027 Hotlink

2)ETPE4-1

Page 110: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

110 (270)

BSCC_4411 LANU1

5.2B05.2P

GTIC1

5.9B01.4J

CHES009 ETPLANETPE 0-0

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet

FUPosition

Cabinet

Type Use NoteETPEINDEX

BSCC_4310

LANU 1

1.10B05.1C

BSCC ETC 2 2.0B01.4J

BSCD CHES022

ETPLAN

ETPE2-1

BSCC_4312

LANU 1

1.10B05.1G

BSCC ETC 2 2.0B06.4J

BSCD CHES023

ETPLAN

ETPE3-0

BSCC_4313

LANU 1

1.10B05.1J

BSCC ETC 3 2.3B01.4J

BSCD CHES025

ETPLAN

ETPE2-0

BSCC_4315

LANU 1

1.10B05.1N

BSCC ETC 3 2.3B06.4J

BSCD CHES026

ETPLAN

ETPE3-1

BSCC_4316

LANU 1

1.10B05.1P

BSCC ETC 4 2.6B01.4J

BSCD CHES028

ETPLAN

ETPE4-0

BSCC_4317

LANU 1

1.10B05.1R

BSCC ETC 4 2.6B06.4J

BSCD CHES029

ETPLAN

ETPE5-0

BSCC_4318

LANU 1

1.10B05.2C

BSCC ETC 5 2.9B01.4J

BSCD CHES030

ETPLAN

ETPE4-1

BSCC_4319

LANU 1

1.10B05.2E

BSCC ETC 5 2.9B06.4J

BSCD CHES031

ETPLAN

ETPE5-1

BSCD_4351

ETC4

2.6F07.SB2-1

BSCD GSW2KB 1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPE5-0

BSCD_4363

ETC4

2.6F07.SB3-1

BSCD GSW2KB 1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1),ETPE5-0

BSCD_4365

ETC4

2.6F02.SB3-1

BSCD GSW2KB 1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1),ETPE4-0

BSCD_4353

ETC4

2.6F02.SB2-1

BSCD GSW2KB 1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPE4-0

BSCD_4355

ETC2

2.0F07.SB2-1

BSCD GSW2KB 1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPE3-0

BSCD_4367

ETC2

2.0F07.SB3-1

BSCD GSW2KB 1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1),ETPE3-0

BSCD_4625

ETC3

2.3F02.SB3-1

BSCD GSW2KB 1

1.3F06.SB2-0

BSCC

CSB023 Hotlink 2) 3)ETPE2-0

BSCD_4621

ETC3

2.3F02.SB2-1

BSCD GSW2KB 1

1.3F07.SB2-0

BSCC

CSB023 Hotlink

2)Default

ETPE2-0

BSCD_4623

ETC2

2.0F02.SB2-1

BSCD GSW2KB 1

1.3F07.SB2-1

BSCC

CSB023 Hotlink 2)ETPE2-1

BSCD_4627

ETC2

2.0F02.SB3-1

BSCD GSW2KB 1

1.3F06.SB2-1

BSCC

CSB023 Hotlink 2) 3)ETPE2-1

Page 111: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

111 (270)

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this

slot(s))

2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in FlexiBSC upgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair byredundancy pair, the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to beconnected if transmission redundancy is upgraded to HW redundancy.

3)These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02 istaken in use.

Add needed 2N Redundancy cables.Equipping Cable from Cable to

ETPEINDEX

No Cabinet FU Position Cabinet FU Position Type Use Note

BSCC_1242 BSCC GTIC1

5.9B02.4A

BSCC GTIC0

5.6B02.4A

CHFX006 2N ETPE0-0 /ETPE0-1

BSCC_1252 BSCC GTIC1

5.9B07.4A

BSCC GTIC0

5.6B07.4A

CHFX006 2N ETPE1-0 /ETPE1-1

BSCD_4454 BSCD ETC5

2.9B07.4A

BSCD ETC4

2.6B07.4A

CHFX006 2N 1) 2) ETPE5-1 /ETPE5-0

BSCD_4455 BSCD ETC5

2.9B02.4A

BSCD ETC4

2.6B02.4A

CHFX006 2N 1) 2) ETPE4-1 /ETPE4-0

BSCD_4456 BSCD ETC2

2.0B07.4A

BSCD ETC3

2.3B07.4A

CHFX006 2N 1) 2) ETPE3-1 /ETPE3-0

BSCD_4457 BSCD ETC2

2.0B02.4A

BSCD ETC3

2.3B02.4A

CHFX006 2N 1) 2) ETPE2-1 /ETPE2-0

Notes:1) These cables are not included in parts list2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by redundancy pair,the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to be connected iftransmission redundancy is upgraded to HW redundancy.

Check SW256B dip switching. See appendix 1

11.2.1.3.4 Change MCMU-1 to SP-EX, SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:MCMU,1:SE;ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SP;

ZUSC:EMB,1:SE;

Page 112: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

112 (270)

ZUSC;EMB,1:TE;ZUSC:EMB,1:SP;

ZUSC:SWU,1:SE; ZUSC:SWU,1:TE; ZUSC:SWU,1:WO;

ZUSC:SWU,3:SE;ZUSC:SWU,3:TE;ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE;ZUSC:SWU,5:TE;ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE;ZUSC:SWU,7:TE;ZUSC:SWU,7:WO;

11.2.2 Create HW Configuration

Create cartridges if not exist (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double Cabinet.)

GTIC-0 cartridge:ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

GTIC-1 catridge:ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 catridge:ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 catridge:ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 catridge:ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 catridge:ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

Create ETPE functional unit (BSC 3i 1000/2000, Upgraded Flexi Single/Double Cabinet)For BSC 3i 1000/Upgraded Flexi Single CabinetZWTU:ETPE,0,0:1A5-6;ZWTU:ETPE,0,1:1A5-9;

ZWTU:ETPE,1,0:1A5-6;ZWTU:ETPE,1,1:1A5-9;

For BSC 3i 2000/Upgraded Flexi Double Cabinet.

ZWTU:ETPE,0,0:1A5-9;ZWTU:ETPE,0,1:1A5-6;ZWTU:ETPE,1,0:1A5-9;ZWTU:ETPE,1,1:1A5-6;

Page 113: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

113 (270)

ZWTU:ETPE,2,0:1B2-3;ZWTU:ETPE,2,1:1B2-0;

ZWTU:ETPE,3,0:1B2-0;ZWTU:ETPE,3,1:1B2-3;

ZWTU:ETPE,4,0:1B2-6;ZWTU:ETPE,4,1:1B2-9;

ZWTU:ETPE,5,0:1B2-6;ZWTU:ETPE,5,1:1B2-9;

Create ETPE plug-in unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single Cabinet

ZWTP:ETPE,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPE,0,1:ETP,0,1;

ZWTP:ETPE,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;ZWTP:ETPE,1,1:ETP,0,6;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ZWTP:ETPE,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPE,0,1:ETP,0,1;ZWTP:ETPE,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;ZWTP:ETPE,1,1:ETP,0,6;

ZWTP:ETPE,2,0:ETP,0,1::ETPCS,8,1600&&1663,TSL,0&&31:ETPPS,8,1344&&1407,TSL,0&&31::;ZWTP:ETPE,2,1:ETP,0,1;ZWTP:ETPE,3,0:ETP,0,6::ETPCS,8,1664&&1727,TSL,0&&31:ETPPS,8,1728&&1791,TSL,0&&31::;ZWTP:ETPE,3,1:ETP,0,6;ZWTP:ETPE,4,0:ETP,0,1::ETPCS,8,64&&127,TSL,0&&31:ETPPS,8,192&&255,TSL,0&&31::;ZWTP:ETPE,4,1:ETP,0,1;ZWTP:ETPE,5,0:ETP,0,6::ETPCS,8,1088&&1151,TSL,0&&31:ETPPS,8,1216&&1279,TSL,0&&31::;ZWTP:ETPE,5,1:ETP,0,6;

Note:For legacy A-interface: Hotlinks are connected from port 0&1 to GSWs. ETPCS functionality is created in plugin unit to support legacy A interface.For A over IP: Traffic will be routed though EEP interface created (via ETPA card).For PS via PCU2_E cards: No separate PCMs are required. This will use PEP eth link created in ETP cards tocommunicate with PCU2_E cards in BCSU.For PS via PCU2_D cards: Hotlinks are connected from port 2&3 to GSWs. ETPPS functionality is created inplug in unit to support PS calls via PCU2_D cards (PEP HDLC link)This will support CS calls in (A over IP,A over TDM) and PS calls if PCU2_E or PCU2_D cards are used in BSCs

Connect functional unitsZWUC: ETPE,<pair_number>,<unit_index>:ETP,0:IF=ABIS:;

Note: This command is not needed for redundant unit as there is no PCM configured to it.

Connect hotlink portsZWTA:GSW,0:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPE,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:GSW,1:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPE,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

Page 114: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

114 (270)

For BSC 3i 1000/2000, Upgraded Flexi Single /Double cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinet

ETPE 0-0

ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPE,0,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPE,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPE,0,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPE,0,0:ETP,0:HOTLINK,3:;

ETPE 0-1

ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPE,0,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPE,0,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPE,0,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPE,0,1:ETP,0:HOTLINK,3:;

ETPE 1-0

ZWTA:GSW,0:SW256B,7:HOTLINK,3:ETPE,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,3:ETPE,1,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPE,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPE,1,0:ETP,0:HOTLINK,3:;

ETPE 1-1

ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPE,1,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPE,1,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPE,1,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPE,1,1:ETP,0:HOTLINK,3:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ETPE 0-0

ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPE,0,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPE,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPE,0,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPE,0,0:ETP,0:HOTLINK,3:;

ETPE 0-1

ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPE,0,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPE,0,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPE,0,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPE,0,1:ETP,0:HOTLINK,3:;

ETPE 1-0

ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPE,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPE,1,0:ETP,0:HOTLINK,1:;

Page 115: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

115 (270)

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPE,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPE,1,0:ETP,0:HOTLINK,3:;

ETPE 1-1

ZWTA:GSW,0:SW256B,7:HOTLINK,3:ETPE,1,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,3:ETPE,1,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPE,1,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPE,1,1:ETP,0:HOTLINK,3:;

ETPE 2-0

ZWTA:GSW,0:SW256B,6:HOTLINK,2:ETPE,2,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,2:ETPE,2,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,5:HOTLINK,2:ETPE,2,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,2:ETPE,2,0:ETP,0:HOTLINK,3:;

ETPE 2-1

ZWTA:GSW,0:SW256B,6:HOTLINK,3:ETPE,2,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,3:ETPE,2,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,5:HOTLINK,3:ETPE,2,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,3:ETPE,2,1:ETP,0:HOTLINK,3:;

ETPE 3-0

ZWTA:GSW,0:SW256B,6:HOTLINK,4:ETPE,3,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,4:ETPE,3,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,6:ETPE,3,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,6:HOTLINK,6:ETPE,3,0:ETP,0:HOTLINK,3:;

ETPE 3-1

ZWTA:GSW,0:SW256B,6:HOTLINK,5:ETPE,3,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,5:ETPE,3,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,7:ETPE,3,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,6:HOTLINK,7:ETPE,3,1:ETP,0:HOTLINK,3:;

ETPE 4-0

ZWTA:GSW,0:SW256B,0:HOTLINK,2:ETPE,4,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,2:ETPE,4,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,6:ETPE,4,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,6:ETPE,4,0:ETP,0:HOTLINK,3:;

ETPE 4-1

ZWTA:GSW,0:SW256B,0:HOTLINK,3:ETPE,4,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,3:ETPE,4,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,7:ETPE,4,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,7:ETPE,4,1:ETP,0:HOTLINK,3:;

Page 116: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

116 (270)

ETPE 5-0

ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPE,5,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPE,5,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPE,5,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPE,5,0:ETP,0:HOTLINK,3:;

ETPE 5-1

ZWTA:GSW,0:SW256B,4:HOTLINK,3:ETPE,5,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,3:ETPE,5,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,7:ETPE,5,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,4:HOTLINK,7:ETPE,5,1:ETP,0:HOTLINK,3:;

Configure ETPSIG-M TCP/IP stack configuration for active ETPE(SE-NH).(For example ETPE 0-0)ZQRA:ETPE, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPE, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPE, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M TCP/IP stack configuration for redundant ETPE(SE-NH).(For example ETPE 0-1)ZQRA:ETPE, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPE, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPE, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M IP address with parameters PDM to active ETPE BOND0 interface.(For example ETPE 0-0)ZQRN:ETPE,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Configure ETPSIG-M IP address with parameters PDM to redundant ETPE BOND0 interface.(For example ETPE0-1)ZQRN:ETPE,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Create ETPSIG-C IP address for active ETPE (SE-NH).(For example ETPE 0-0)ZQRN:ETPE,<pair_number>,>unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSIG-CZD2C:M:BCSU,<unit_index>::ETPE,<pair_number>,<unit_index>:::;ZD2C:C,NOR:BCSU,<unit_index>::ETPE,<pair_umber>,<unit_index>:::;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units.For redundant card (For example ETPE 0-1) IUA messaging for ETPSIG-M will be created with same BCSUalready selected for Active card (ETPE 0-0).

Create EL0 IP address to ETPEZQRA:ETPE,<pair_number>,<unit_index>::EL0::UP;ZQRN:ETPE,<pair_number>,<unit_index>::EL0,:"<ip_address>",<network_mask_length>,L,:;

Create EEP interface for traffic between ETPE and ETPAZQRA:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPE,<pair_number>,<unit_index>::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Note: In case of BSC 3i 1000/2000 or Upgraded flexi Single cabinet/Double cabinet the following pop upwill occur in macro.

Page 117: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

117 (270)

Select the required application to proceed further.

Note: Create the PEP link to ETPGID 0 first if you want to get the ETP object ID for the ETPGID to match inNetAct.

Create PEP interface if PCU2-E’s are in useZQRA:ETPE, <pair_number>,<unit_index>::<PEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPE,<pair_number>,<unit_index>::<PEP_VLAN>,:”<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPE, <pair_number>,<unit_index>::<PEP_VLAN>:"<ip_address>":TAG,"PEP":;

Create IM0 IP address to ETPEZQRA:ETPE,<pair_number>,<unit_index>::IM0::UP;ZQRN:ETPE,<pair_number>,<unit_index>::IM0:"<ip_address>",<network_mask_length>,P,I::;

Create IN0 IP address to ETPEZQRA:ETPE,<pair_number>,<unit_index>::IN0::UP;ZQRN:ETPE,<pair_number>,<unit_index>::IN0:"<ip_address>",<network_mask_length>,P,I::;

Create static routeZQKC:ETPE, <pair_number>,<unit_index>:::"<Gateway ip address>":LOG:;

Change state of ETPE to TE-EXZUSC:ETPE,<pair_number>,<unit_index>:SE;ZUSC:ETPE,<pair_number>,<unit_index>:TE;

11.2.3 Check Plug-in unit software

Note: The flashing does not succeed if the username and password in the ETP card does not match the BSC’susername & password. Refer Appendix 6 to see an example how to update the username & password via ETPservice terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Check the CBUHAN version in BSC package.

Page 118: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

118 (270)

ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Page 119: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

119 (270)

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPE.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Page 120: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

120 (270)

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

The redundant card eSW update will be done in similar way.

11.2.4 Diagnostic

Run diagnostic to the ETPE ZUDU:ETPE,<pair number>,<unit index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPE to WO-EXZUSC:ETPE,<pair number>,<unit index>:WO;

11.2.5 Check PCU configuration

If Packet Abis interface is also used in PS traffic check PCU configuration. PCU2-D or PCU2-E must be created tothe PCUPAB function that it can carry Packet Abis PS data.

For PCU2_E cards PEP interface creation is required to support PEP Eth link. These creations are mentioned inthe below document.

PCU configuration can be checked with following command:ZWTI:P:BCSU,<unit_index>;

Use “ BSCPCU HW implementation for PS traffic” procedure if PCU configurations need to change.ETP- PCU connection.

ZESK:ETPE,<pair number>:BCSU,<index>:PCU,<index>:;

Note: This is required for both PCU2_E and PCU2_D cards.

Page 121: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

121 (270)

12 PACKET ABIS OVER TDM (ETPT), PIU TYPE ETP

The following pop up will be displayed by macro for each BSC variants.

Select the required application and tracks to proceed further.

12.1 Creation of ETPT unit with transmission/line protection.

Note!Macro asks in this point redundancy type and Plug-in Unit location. After that macro check possibleunit/PCM overlapping.

If there is overlapping PCM areas move or remove resources from them. Macro will remove unit and Plug-in Unitsautomatically after needed recourses are moved or removed.

Note:- Refer Appendix 2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

12.1.1 Install Plug-in units, terminators and cables

12.1.1.1 Terminators and setting modules

For initial BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet

Page 122: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

122 (270)

For BSC 3i 1000/Upgraded Flexi Single cabinet

Terminators and setting modules

Position ID Name FU Cabinet Use NoteETPTINDEX

5.6B 014E C108585 ADMOD01 GTIC 0 BSCC

For ETPTETSI 1)

ETPT 0-0

5.6B 014E C108704 ADMOD17 GTIC 0 BSCC

For ETPTANSI 2)

ETPT 0-0

5.6B 064E C108585 ADMOD01 GTIC 0 BSCC

For ETPTETSI 1)

ETPT 1-0

5.6B 064E C108704 ADMOD17 GTIC 0 BSCC

For ETPTANSI 2)

ETPT 1-0

5.6B09.2J C101501 CABID1A GTIC 0 BSCC

Cabinetidentification

ETPT 0-0/ ETPT1-0

5.6B09.2L C101557 CARID53 GTIC 0 BSCC

Cartridgeidentification

ETPT 0-0/ ETPT1-0

Notes:1)When ETP PIU is used ETPT ETSI in this slot2) When ETP PIU is used ETPT ANSI in this slot

For BSC 3i 2000/Upgraded Flexi Double cabinet.

Terminators and setting modules

Position ID Name FU Cabinet Use NoteETPTINDEX

2.0B 064E C108585 ADMOD01 ETC 2 BSCD

For ETPTETSI 1) ETPT 3-0

2.0B 064E C108704 ADMOD17 ETC 2 BSCD

For ETPTANSI 2) ETPT 3-0

2.3B 064E C108585 ADMOD01 ETC 3 BSCD

For ETPTETSI 1)

ETPT 11-0

2.3B 064E C108704 ADMOD17 ETC 3 BSCD

For ETPTANSI 2)

ETPT 11-0

2.6B 014E C108585 ADMOD01 ETC 4 BSCD

For ETPTETSI 1) ETPT 4-0

2.6B 014E C108704 ADMOD17 ETC 4 BSCD

For ETPTANSI 2) ETPT 4-0

2.6B 064E C108585 ADMOD01 ETC 4 BSCD

For ETPTETSI 1) ETPT 5-0

2.6B 064E C108704 ADMOD17 ETC 4 BSCD

For ETPTANSI 2) ETPT 5-0

2.9B 014E C108585 ADMOD01 ETC 5 BSCD

For ETPTETSI 1)

ETPT 12-0

2.9B 014E C108704 ADMOD17 ETC 5 BSCD

For ETPTANSI 2)

ETPT 12-0

2.9B 064E C108585 ADMOD01 ETC 5 BSCD

For ETPTETSI 1)

ETPT 13-0

Page 123: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

123 (270)

2.9B 064E C108704 ADMOD17 ETC 5 BSCD

For ETPTANSI 2)

ETPT 13-0

2.0B09.2J C101502 CABID1B ETC 2 BSCD

Cabinetidentification

ETPT 3-0

2.0B09.2L C101535 CARID20 ETC 2 BSCD

Cartridgeidentification

ETPT 3-0

2.3B09.2J C101502 CABID1B ETC 3 BSCD

Cabinetidentification

ETPT11-0

2.3B09.2L C101536 CARID21 ETC 3 BSCD

Cartridgeidentification

ETPT11-0

2.6B09.2J C101502 CABID1B ETC 4 BSCD

Cabinetidentification

ETPT 4-0/ ETPT5-0

2.6B09.2L C101538 CARID23 ETC 4 BSCD

Cartridgeidentification

ETPT 4-0/ ETPT5-0

2.9B09.2J C101502 CABID1B ETC 5 BSCD

Cabinetidentification

ETPT 12-0/ ETPT13-0

2.9B09.2L C101539 CARID24 ETC 5 BSCD

Cartridgeidentification

ETPT 12-0/ ETPT13-0

Notes:When ETP PIU is used ETPT ETSI in this slot2)When ETP PIU is used ETPT ANSI in this slot

12.1.1.2 Plug-in unit installation

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet.

For BSC 3i 1000/Upgraded Flexi Single cabinet.CartridgeSGC1C position

Unit Cartridge /Slots

ETPTgroupindex

Cartridge / slot / Interfaceof mate ETS2

STMUindex

5.6 GTIC-0 1

0-0GTIC 0 / 8/ SB1 14

5.6 GTIC-0 6

1-0GTIC 0 / 8/ SB2 14

Note:Check Appendix 5 for ETP strappings and STMU strappings..

Page 124: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

124 (270)

For BSC 3i 2000/Upgraded Flexi Double cabinet

Cartridge SGC1Cposition

Unit Cartridge /Slots

ETPT groupindex

Cartridge / slot / Interface ofmate ETS2

STMU index

2.0 ETC-2 6 3-0 GTIC 1/ 3/ SB2 202.3 ETC-3 6 11-0 GTIC 1/ 3/ SB1 202.6 ETC-4 1 4-0 GTIC 0 / 4/ SB2 62.6 ETC-4 6 5-0 GTIC 1/ 4/ SB2 222.9 ETC-5 1 12-0 GTIC 0 / 4/ SB1 62.9 ETC-5 6 13-0 GTIC 1 / 4/ SB1 22

Note:Check Appendix 5 for ETP strappings and STMU strappings..

Page 125: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

125 (270)

12.1.1.3 Cabling

12.1.1.3.1 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 SE-NH state

ZUSC:MCMU,0:SP; If neededZUSC:MCMU,0:TE;ZUSC:MCMU,0:SE;ZUSC:MCMU,0:SE;

ZUSC:EMB,0:SP;if neededZUSC:EMB,0:TE;ZUSC:EMB,0:SE;ZUSC:EMB,0:SE;

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

12.1.1.3.1.1 For initial BSC 3i 1000/2000

Page 126: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

126 (270)

12.1.1.3.1.1.1 For BSC 3i 1000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 0 5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 0 5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add cables if required.

Equipping Cable from Cable to

No OldCab/

Old FU/ OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_714 BSCC GTIC 0 5.6F02.SB1-0

BSCC GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

ETPT0-0

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC 0 5.6F02.SB2-0

BSCC GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

ETPT0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC GTIC 1 5.9F01.SB1-0

BSCC GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 1)

ETPT1-0

GTIC 0 5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC GTIC 1 5.9F01.SB2-0

BSCC GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 1)

ETPT1-0

GTIC 0 5.6F07.SB3-0

1.0F08.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Page 127: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

127 (270)

Add ETPLAN from LANU-0 to the required tracks.

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4400 LANU 0 5.0B05.2E

GTIC 0 5.6B06.4G

CHES009 ETPLAN ETPT 1-0

BSCC_4402 LANU 0 5.0B05.2J

GTIC 0 5.6B01.4G

CHES008 ETPLAN ETPT 0-0

12.1.1.3.1.1.2 For BSC 3i 2000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 0 5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 0 5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_718 GTIC 0 5.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 2)

BSCC_719 GTIC 0 5.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 2)

BSCC_730 GTIC 1 5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 3)

BSCC_731 GTIC 1 5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 3)

BSCC_734 GTIC 1 5.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 4)

BSCC_735 GTIC 1 5.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 4)

Notes:1)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3)These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4)These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Add ETPLAN from LANU-0 to the required tracksEquipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use NoteETPTINDEX

BSCC_4302 LANU0

5.0B05.1E

BSCC ETC2

2.0B06.4G

BSCD CHES044 ETPLAN ETPT 3-0

Page 128: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

128 (270)

BSCC_4305 LANU0

5.0B05.1L

BSCC ETC3

2.3B06.4G

BSCD CHES042 ETPLAN ETPT11-0

BSCC_4306 LANU0

5.0B05.1N

BSCC ETC4

2.6B01.4G

BSCD CHES042 ETPLAN ETPT 4-0

BSCC_4307 LANU0

5.0B05.1P

BSCC ETC4

2.6B06.4G

BSCD CHES041 ETPLAN ETPT 5-0

BSCC_4308 LANU0

5.0B05.1R

BSCC ETC5

2.9B01.4G

BSCD CHES041 ETPLAN ETPT12-0

BSCC_4309 LANU0

5.0B05.2C

BSCC ETC5

2.9B06.4G

BSCD CHES040 ETPLAN ETPT13-0

Add Hotlink cables if required

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FU Position Cabinet Type Use NoteETPTINDEX

BSCD_4350

ETC4

2.6F07.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB027 Hotlink 1)ETPT5-0

BSCD_4352 ETC4

2.6F02.SB2-0

BSCD GSW2KB0

1.0F01.SB2-0

BSCC CSB027 Hotlink 1)ETPT4-0

BSCD_4354 ETC2

2.0F07.SB2-0

BSCD GSW2KB0

1.0F07.SB3-0

BSCC CSB022 Hotlink 1)ETPT3-0

BSCD_4356 ETC5

2.9F07.SB2-0

BSCD GSW2KB0

1.0F07.SB2-0

BSCC CSB029 Hotlink 1)ETPT13-0

BSCD_4358 ETC5

2.9F02.SB2-0

BSCD GSW2KB0

1.0F08.SB2-0

BSCC CSB027 Hotlink 1)ETPT12-0

BSCD_4360 ETC3

2.3F07.SB2-0

BSCD GSW2KB0

1.0F02.SB2-0

BSCC CSB027 Hotlink 1)ETPT11-0

BSCD_4362 ETC4

2.6F07.SB3-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB027 Hotlink 1),ETPT5-0

BSCD_4364 ETC4

2.6F02.SB3-0

BSCD GSW2KB0

1.0F01.SB4-0

BSCC CSB027 Hotlink 1),ETPT4-0

BSCD_4366 ETC2

2.0F07.SB3-0

BSCD GSW2KB0

1.0F07.SB4-0

BSCC CSB021 Hotlink 1),ETPT3-0

BSCD_4368 ETC5

2.9F07.SB3-0

BSCD GSW2KB0

1.0F06.SB2-0

BSCC CSB029 Hotlink 1),ETPT13-0

BSCD_4370 ETC5

2.9F02.SB3-0

BSCD GSW2KB0

1.0F08.SB1-0

BSCC CSB029 Hotlink 1),ETPT12-0

BSCD_4372 ETC3

2.3F07.SB3-0

BSCD GSW2KB0

1.0F02.SB4-0

BSCC CSB024 Hotlink 1),ETPT11-0

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

Page 129: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

129 (270)

12.1.1.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.1.1.3.1.2.1 For upgraded flexi BSC Single cabinet.

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC0

5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC0

5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_715 BSCC GTIC0

5.6F02.SB2-0

BSCC GSW2KB0

1.0F02.SB4-0

CSB030 2)

ETPT 0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC GTIC1

5.9F01.SB1-0

BSCC GSW2KB0

1.0F06.SB2-0

CSB027 1)

ETPT 1-0

GTIC0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC GTIC1

5.9F01.SB2-0

BSCC GSW2KB0

1.0F07.SB2-0

CSB027 1)

ETPT 1-0

GTIC0

5.6F07.SB3-0

1.0F08.SB1-1

BSCC_714 BSCC GTIC0

5.6F02.SB1-0

BSCC GSW2KB0

1.0F02.SB2-0

CSB031 2)

ETPT 0-0

5.6F02.SB2-0

1.0F02.SB2-1

Page 130: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

130 (270)

Notes: These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use. These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is taken inuse.

Add following cables if required

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4400 LANU0

1.8B05.2G

GTIC 0 5.6B06.4G

CHES023 ETPLAN ETPT1-0

BSCC_4402 LANU0

1.8B05.2L

GTIC 0 5.6B01.4G

CHES024 ETPLAN ETPT0-0

12.1.1.3.1.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC0

5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC0

5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_714 GTIC0

5.6F02.SB1-0

GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

BSCC_715 GTIC0

5.6F02.SB2-0

GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

BSCC_718 GTIC0

5.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 3)

BSCC_719 GTIC0

5.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 3)

BSCC_726 GTIC1

5.9F01.SB1-0

GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 4)

BSCC_727 GTIC1

5.9F01.SB2-0

GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 4)

BSCC_730 GTIC1

5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 5)

BSCC_731 GTIC1

5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 5)

BSCC_734 GTIC1

5.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 6)

BSCC_735 GTIC1

5.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 6)

Page 131: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

131 (270)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Add ETPLAN from LANU-0 for the required tracks.

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPTINDEX

BSCC_4302 LANU0

1.8B05.1G

BSCCETC2

2.0B06.4G

BSCD CHES021 ETPLANETPT 3-0

BSCC_4305 LANU0

1.8B05.1N

BSCCETC3

2.3B06.4G

BSCD CHES024 ETPLANETPT11-0

BSCC_4306 LANU0

1.8B05.1P

BSCCETC4

2.6B01.4G

BSCD CHES026 ETPLANETPT 4-0

BSCC_4307 LANU0

1.8B05.1R

BSCCETC4

2.6B06.4G

BSCD CHES027 ETPLANETPT 5-0

BSCC_4308 LANU0

1.8B05.2C

BSCCETC5

2.9B01.4G

BSCD CHES028 ETPLANETPT12-0

BSCC_4309 LANU0

1.8B05.2E

BSCCETC5

2.9B06.4G

BSCD CHES029 ETPLANETPT13-0

Add Hotlink cables if required

CABLE TO

EquippingNo:

FU Position Cabinet FU Position Cabinet Type Use Note

ETPTINDEX

BSCD_4350

ETC4

2.6F07.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB027 Hotlink 1)

ETPT 5-0BSCD_4352 ETC

42.6F02.SB2-0

BSCD GSW2KB0

1.0F01.SB2-0

BSCC CSB027 Hotlink 1)

ETPT 4-0BSCD_4354 ETC

22.0F07.SB2-0

BSCD GSW2KB0

1.0F07.SB3-0

BSCC CSB022 Hotlink 1)

ETPT 3-0BSCD_4356 ETC

52.9F07.SB2-0

BSCD GSW2KB0

1.0F07.SB2-0

BSCC CSB029 Hotlink 1)ETPT 13-0

BSCD_4358 ETC5

2.9F02.SB2-0

BSCD GSW2KB0

1.0F08.SB2-0

BSCC CSB027 Hotlink 1)ETPT 12-0

Page 132: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

132 (270)

BSCD_4360 ETC3

2.3F07.SB2-0

BSCD GSW2KB0

1.0F02.SB2-0

BSCC CSB027 Hotlink 1)ETPT 11-0

BSCD_4362 ETC4

2.6F07.SB3-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB027 Hotlink 1),

ETPT 5-0BSCD_4364 ETC

42.6F02.SB3-0

BSCD GSW2KB0

1.0F01.SB4-0

BSCC CSB027 Hotlink 1),

ETPT 4-0BSCD_4366 ETC

22.0F07.SB3-0

BSCD GSW2KB0

1.0F07.SB4-0

BSCC CSB021 Hotlink 1),

ETPT 3-0BSCD_4368 ETC

52.9F07.SB3-0

BSCD GSW2KB0

1.0F06.SB2-0

BSCC CSB029 Hotlink 1),ETPT 13-0

BSCD_4370 ETC5

2.9F02.SB3-0

BSCD GSW2KB0

1.0F08.SB1-0

BSCC CSB029 Hotlink 1),ETPT 12-0

BSCD_4372 ETC3

2.3F07.SB3-0

BSCD GSW2KB0

1.0F02.SB4-0

BSCC CSB024 Hotlink 1),ETPT 11-0

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

Check SW256B dips switching. See appendix1

12.1.1.3.2 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:MCMU,0:SE;ZUSC:MCMU,0:TE;ZUSC:MCMU,0:SP;ZUSC:MCMU,0:WO;

ZUSC:EMB,0:SE;ZUSC:EMB,0:TE;ZUSC:EMB,0:SP;ZUSC:EMB,0:WO;

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;

12.1.1.3.3 Change MCMU-1, SWU-1, SWU-3, and SWU-5 and SWU-7 SE-NH state

Page 133: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

133 (270)

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SE;ZUSC:MCMU,1:SE;

ZUSC:EMB,1:TE;ZUSC:EMB,1:SE;ZUSC:EMB,1:SE;

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;ZUSC:SWU,3:SE;

ZUSC:SWU,5:TE;ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

12.1.1.3.3.1 For initial BSC 3i 1000/2000

12.1.1.3.3.1.1 For BSC 3i 1000

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add cables if required

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716

BSCC

GTIC0

5.6F02.SB1-1

BSCC

GSW2KB 1

1.3F03.SB2-0

CSB029

Hotlink

2)

Page 134: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

134 (270)

5.6F02.SB2-1

1.3F02.SB2-1

ETPT 0-0

BSCC_717

BSCC

GTIC0

5.6F02.SB2-1

BSCC

GSW2KB 1

1.3F02.SB4-0

CSB028

Hotlink

2)

5.6F02.SB3-1

1.3F02.SB4-1

ETPT 0-0

BSCC_728

BSCC

GTIC1

5.9F01.SB1-1

BSCC

GSW2KB 1

1.3F06.SB2-0

CSB025

Hotlink

1)

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

ETPT 1-0

BSCC_729

BSCC

GTIC1

5.9F01.SB2-1

BSCC

GSW2KB 1

1.3F07.SB2-0

CSB025

Hotlink

1)

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

ETPT 1-0

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is taken inuse.

Add ETPLAN from LANU-1 for the required tracks.

Equipping CABLE FROM CABLE TO

ETPTINDEX

No FU Position FU Position Type Use Note

BSCC_4406 LANU1

5.2B05.2E

GTIC0

5.6B06.4J

CHES008 ETPLAN ETPT1-0

BSCC_4408 LANU1

5.2B05.2J

GTIC0

5.6B01.4J

CHES007 ETPLAN ETPT0-0

12.1.1.3.3.1.2 For BSC 3i 2000

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_720 GTIC 0 5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 2)

Page 135: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

135 (270)

BSCC_721 GTIC 0 5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 2)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 3)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 3)

BSCC_736 GTIC 1 5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 4)

BSCC_737 GTIC 1 5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 4)

Notes:1)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2)These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3)These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4)These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Add ETPLAN from LANU-1 for the required tracks

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use Note

BSCC_4312 LANU 1 5.2B05.1E

BSCC ETC 2 2.0B06.4J

BSCD CHES042 ETPLAN ETPT 3-0

BSCC_4315 LANU 1 5.2B05.1L

BSCC ETC 3 2.3B06.4J

BSCD CHES040 ETPLAN ETPT11-0

BSCC_4316 LANU 1 5.2B05.1N

BSCC ETC 4 2.6B01.4J

BSCD CHES040 ETPLAN ETPT 4-0

BSCC_4317 LANU 1 5.2B05.1P

BSCC ETC 4 2.6B06.4J

BSCD CHES039 ETPLAN ETPT 5-0

BSCC_4318 LANU 1 5.2B05.1R

BSCC ETC 5 2.9B01.4J

BSCD CHES039 ETPLAN ETPT12-0

BSCC_4319 LANU 1 5.2B05.2C

BSCC ETC 5 2.9B06.4J

BSCD CHES038 ETPLAN ETPT13-0

Add Hotlinks if required

Equipping CABLE TO

No Position Cabinet

FUPosition

Cabinet

Type Use Note

ETPTINDEX

BSCD_4351

ETC 4

2.6F07.SB2-1

BSCD GSW2KB 1

1.3F05.SB2-0

BSCC CSB025

Hotlink

1)ETPT5-0

BSCD_4353

ETC 4

2.6F02.SB2-1

BSCD GSW2KB 1

1.3F01.SB2-0

BSCC CSB025

Hotlink

1)ETPT4-0

BSCD_4355

ETC 2

2.0F07.SB2

BSCD GSW2KB 1

1.3F07.SB3

BSCC CSB020

Hotlink

1) ETPT3-0

Page 136: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

136 (270)

-1 -0

BSCD_4357

ETC 5

2.9F07.SB2-1

BSCD GSW2KB 1

1.3F07.SB2-0

BSCC CSB027

Hotlink

1)ETPT13-0

BSCD_4359

ETC 5

2.9F02.SB2-1

BSCD GSW2KB 1

1.3F08.SB2-0

BSCC CSB026

Hotlink

1)ETPT12-0

BSCD_4361

ETC 3

2.3F07.SB2-1

BSCD GSW2KB 1

1.3F02.SB2-0

BSCC CSB025

Hotlink

1)ETPT11-0

BSCD_4363

ETC 4

2.6F07.SB3-1

BSCD GSW2KB 1

1.3F05.SB4-0

BSCC CSB025

Hotlink

1),ETPT5-0

BSCD_4365

ETC 4

2.6F02.SB3-1

BSCD GSW2KB 1

1.3F01.SB4-0

BSCC CSB025

Hotlink

1),ETPT4-0

BSCD_4367

ETC 2

2.0F07.SB3-1

BSCD GSW2KB 1

1.3F07.SB4-0

BSCC CSB019

Hotlink

1),ETPT3-0

BSCD_4369

ETC 5

2.9F07.SB3-1

BSCD GSW2KB 1

1.3F06.SB2-0

BSCC CSB027

Hotlink

1),ETPT13-0

BSCD_4371

ETC 5

2.9F02.SB3-1

BSCD GSW2KB 1

1.3F08.SB1-0

BSCC CSB027

Hotlink

1),ETPT12-0

BSCD_4373

ETC 3

2.3F07.SB3-1

BSCD GSW2KB 1

1.3F02.SB4-0

BSCC CSB022

Hotlink

1),ETPT11-0

Notes: 1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

12.1.1.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.1.1.3.3.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2).

Move and reconnect or add cables if required.Equipping Cable from Cable to

Page 137: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

137 (270)

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use

Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Hotlink connections ETPT/E to GSW2KB

BSCC_717

BSCC

GTIC0

5.6F02.SB2-1

BSCC

GSW2KB 1

1.3F02.SB4-0

CSB028

2)

5.6F02.SB3-1

1.3F02.SB4-1

ETPT 0-0

BSCC_728

BSCC

GTIC1

5.9F01.SB1-1

BSCC

GSW2KB 1

1.3F06.SB2-0

CSB025

1)

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

ETPT 1-0

BSCC_729

BSCC

GTIC1

5.9F01.SB2-1

BSCC

GSW2KB 1

1.3F07.SB2-0

CSB025

1)

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

ETPT 1-0

BSCC_716

BSCC

GTIC0

5.6F02.SB1-1

BSCC

GSW2KB 1

1.3F03.SB2-0

CSB029

2)

5.6F02.SB2-1

1.3F02.SB2-1

ETPT 0-0

Notes:1) These Hotlinks are moved in a situation where ETPT/E in GTIC 0 & 1 slot 06/07 is taken in use.2) These Hotlinks are moved in a situation where ETPT/E HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Add following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_4406 LANU 1 1.10B05.2G

GTIC0

5.6B06.4J

CHES022 ETPLAN ETPT1-0

BSCC_4408 LANU 1 1.10B05.2L

GTIC0

5.6B01.4J

CHES023 ETPLAN ETPT0-0

12.1.1.3.3.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

Page 138: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

138 (270)

No FU Position FU Position Type Use Note

BSCC_712 GTIC 0 5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC 0 5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_716 GTIC 0 5.6F02.SB1-1

GSW2KB1

1.3F02.SB2-0

CSB029 Hotlink 2)

BSCC_717 GTIC 0 5.6F02.SB2-1

GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

BSCC_720 GTIC 0 5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 3)

BSCC_721 GTIC 0 5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 3)

BSCC_728 GTIC 1 5.9F01.SB1-1

GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 4)

BSCC_729 GTIC 1 5.9F01.SB2-1

GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 4)

BSCC_732 GTIC 1 5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 5)

BSCC_733 GTIC 1 5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 5)

BSCC_736 GTIC 1 5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 6)

BSCC_737 GTIC 1 5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Add ETPLAN from LANU-0 for the required tracks.

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet

FUPosition

Cabinet

Type Use Note ETPT

INDEXBSCC_4312

LANU 1

1.10B05.1G

BSCCETC 2

2.0B06.4J

BSCD CHES023

ETPLAN

ETPT 3-0

BSCC_4315

LANU 1

1.10B05.1N

BSCCETC 3

2.3B06.4J

BSCD CHES026

ETPLAN

ETPT11-0

Page 139: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

139 (270)

BSCC_4316

LANU 1

1.10B05.1P

BSCCETC 4

2.6B01.4J

BSCD CHES028

ETPLAN

ETPT 4-0

BSCC_4317

LANU 1

1.10B05.1R

BSCCETC 4

2.6B06.4J

BSCD CHES029

ETPLAN

ETPT 5-0

BSCC_4318

LANU 1

1.10B05.2C

BSCCETC 5

2.9B01.4J

BSCD CHES030

ETPLAN

ETPT12-0

BSCC_4319

LANU 1

1.10B05.2E

BSCCETC 5

2.9B06.4J

BSCD CHES031

ETPLAN

ETPT13-0

Add Hotlink cables if required

Equipping CABLE TO

No Position Cabinet FU Position Cabinet Type Use NoteETPTINDEX

BSCD_4351 ETC4

2.6F07.SB2-1

BSCD GSW2KB1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1) ETPT 5-0

BSCD_4353 ETC4

2.6F02.SB2-1

BSCD GSW2KB1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1) ETPT 4-0

BSCD_4355 ETC2

2.0F07.SB2-1

BSCD GSW2KB1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1) ETPT 3-0

BSCD_4357 ETC5

2.9F07.SB2-1

BSCD GSW2KB1

1.3F07.SB2-0

BSCC CSB027 Hotlink 1) ETPT 13-0

BSCD_4359 ETC5

2.9F02.SB2-1

BSCD GSW2KB1

1.3F08.SB2-0

BSCC CSB026 Hotlink 1) ETPT 12-0

BSCD_4361 ETC3

2.3F07.SB2-1

BSCD GSW2KB1

1.3F02.SB2-0

BSCC CSB025 Hotlink 1) ETPT 11-0

BSCD_4363 ETC4

2.6F07.SB3-1

BSCD GSW2KB1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1), ETPT 5-0

BSCD_4365 ETC4

2.6F02.SB3-1

BSCD GSW2KB1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1), ETPT 4-0

BSCD_4367 ETC2

2.0F07.SB3-1

BSCD GSW2KB1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1), ETPT 3-0

BSCD_4369 ETC5

2.9F07.SB3-1

BSCD GSW2KB1

1.3F06.SB2-0

BSCC CSB027 Hotlink 1), ETPT 13-0

BSCD_4371 ETC5

2.9F02.SB3-1

BSCD GSW2KB1

1.3F08.SB1-0

BSCC CSB027 Hotlink 1), ETPT 12-0

BSCD_4373 ETC3

2.3F07.SB3-1

BSCD GSW2KB1

1.3F02.SB4-0

BSCC CSB022 Hotlink 1), ETPT 11-0

Page 140: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

140 (270)

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))

Check SW256B dip switching. See appendix 1

12.1.1.3.4 Change MCMU-1 to SP-EX, SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:MCMU,1:SE;ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SP;

ZUSC:SWU,1:SE;ZUSC:SWU,1:TE;ZUSC:SWU,1:WO;

ZUSC:SWU,3:SE;ZUSC:SWU,3:TE;ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE;ZUSC:SWU,5:TE;ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE;ZUSC:SWU,7:TE;ZUSC:SWU,7:WO;

12.1.1.3.5 Cablings from ETPT card to STMU card

12.1.1.3.5.1 For ini BSC 3i 1000/2000

12.1.1.3.5.1.1 BSC 3i 1000

Add needed Hotlink cables between STMU cards and ETPT cards in GTIC-0/1.

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4700 GTIC 0 5.6F08.SB1-0

GTIC 0 5.6F06.SB1-0

CSB006 Hotlink 1)ETPT 1-0

BSCC_4701 GTIC 0 5.6F08.SB1-1

GTIC 0 5.6F06.SB1-1

CSB006 Hotlink 1)ETPT 1-0

BSCC_4702 GTIC 0 5.6F08.SB2-0

GTIC 0 5.6F01.SB1-0

CSB008 Hotlink 1)ETPT 0-0

BSCC_4703 GTIC 0 5.6F08.SB2-1

GTIC 0 5.6F01.SB1-1

CSB008 Hotlink 1)ETPT 0-0

Notes:1) Cables BSCC_4700 – BSCC_4703 are installed and tied to the front side of the cabinet to be ready forconnectingo plug in units. These cables are used if “ETS2 and its mate ETP(T) ” are used in GTIC 0 and GTIC 1.

Page 141: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

141 (270)

12.1.1.3.5.1.2 BSC3i 2000

Add needed Hotlink cables between STMU cards and ETPT cards in GTIC-0/1 and ETC cartridges

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use NoteETPTINDEX

BSCD_4500 ETC 5 2.9F01.SB1-0

BSCD GTIC 0 5.6F04.SB1-0

BSCC CSB050 Hotlink 1)ETPT12-0

BSCD_4501 ETC 5 2.9F01.SB1-1

BSCD GTIC 0 5.6F04.SB1-1

BSCC CSB050 Hotlink 1)ETPT12-0

BSCD_4502 ETC 4 2.6F01.SB1-0

BSCD GTIC 0 5.6F04.SB2-0

BSCC CSB052 Hotlink 1)ETPT 4-0

BSCD_4503 ETC 4 2.6F01.SB1-1

BSCD GTIC 0 5.6F04.SB2-1

BSCC CSB052 Hotlink 1)ETPT 4-0

BSCD_4504 ETC 5 2.9F06.SB1-0

BSCD GTIC 1 5.9F04.SB1-0

BSCC CSB046 Hotlink 1)ETPT13-0

BSCD_4505 ETC 5 2.9F06.SB1-1

BSCD GTIC 1 5.9F04.SB1-1

BSCC CSB046 Hotlink 1)ETPT13-0

BSCD_4506 ETC 4 2.6F06.SB1-0

BSCD GTIC 1 5.9F04.SB2-0

BSCC CSB048 Hotlink 1)ETPT 5-0

BSCD_4507 ETC 4 2.6F06.SB1-1

BSCD GTIC 1 5.9F04.SB2-1

BSCC CSB048 Hotlink 1)ETPT 5-0

BSCD_4508 ETC 3 2.3F06.SB1-0

BSCD GTIC 1 5.9F03.SB1-0

BSCC CSB050 Hotlink 1)ETPT11-0

BSCD_4509 ETC 3 2.3F06.SB1-1

BSCD GTIC 1 5.9F03.SB1-1

BSCC CSB050 Hotlink 1)ETPT11-0

BSCD_4510 ETC 2 2.0F06.SB1-0

BSCD GTIC 1 5.9F03.SB2-0

BSCC CSB052 Hotlink 1)ETPT 3-0

BSCD_4511 ETC 2 2.0F06.SB1-1

BSCD GTIC 1 5.9F03.SB2-1

BSCC CSB052 Hotlink 1)ETPT 3-0

Notes:

1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETPTin this slot(s)

Page 142: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

142 (270)

12.1.1.3.5.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.1.1.3.5.2.1 For upgraded flexi BSC Single cabinet.

Add needed Hotlink cables between STMU cards and ETPT cards in GTIC-0/1

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4700 GTIC 0 5.6F08.SB1-0

GTIC 0 5.6F06.SB1-0

CSB006 Hotlink 1) ETPT 1-0

BSCC_4701 GTIC 0 5.6F08.SB1-1

GTIC 0 5.6F06.SB1-1

CSB006 Hotlink 1) ETPT 1-0

BSCC_4702 GTIC 0 5.6F08.SB2-0

GTIC 0 5.6F01.SB1-0

CSB008 Hotlink 1) ETPT 0-0

BSCC_4703 GTIC 0 5.6F08.SB2-1

GTIC 0 5.6F01.SB1-1

CSB008 Hotlink 1) ETPT 0-0

Notes:

1) Cables BSCC_4700 – BSCC_4703 are installed and tied to the front side of the cabinet to be ready forconnecting plug in units. These cables are used if “ETS2 and its mate ETP(T) ” are used in GTIC 0 and GTIC 1.

12.1.1.3.5.2.2 For upgraded flexi BSC Double cabinet.

Add needed Hotlink cables between STMU cards and ETPT cards in GTIC-0/1 and ETC cartridges

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use NoteETPTINDEX

BSCD_4500 ETC 5 2.9F01.SB1-0

BSCD GTIC 0 5.6F04.SB1-0

BSCC CSB050 Hotlink 1)ETPT12-0

BSCD_4501 ETC 5 2.9F01.SB1-1

BSCD GTIC 0 5.6F04.SB1-1

BSCC CSB050 Hotlink 1)ETPT12-0

BSCD_4502 ETC 4 2.6F01.SB1-0

BSCD GTIC 0 5.6F04.SB2-0

BSCC CSB052 Hotlink 1)ETPT 4-0

BSCD_4503 ETC 4 2.6F01.SB1-1

BSCD GTIC 0 5.6F04.SB2-1

BSCC CSB052 Hotlink 1)ETPT 4-0

BSCD_4504 ETC 5 2.9F06.SB1-0

BSCD GTIC 1 5.9F04.SB1-0

BSCC CSB046 Hotlink 1)ETPT13-0

BSCD_4505 ETC 5 2.9F06.SB1-1

BSCD GTIC 1 5.9F04.SB1-1

BSCC CSB046 Hotlink 1)ETPT13-0

BSCD_4506 ETC 4 2.6F06.SB1-0

BSCD GTIC 1 5.9F04.SB2-0

BSCC CSB048 Hotlink 1)ETPT 5-0

Page 143: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

143 (270)

BSCD_4507 ETC 4 2.6F06.SB1-1

BSCD GTIC 1 5.9F04.SB2-1

BSCC CSB048 Hotlink 1)ETPT 5-0

BSCD_4508 ETC 3 2.3F06.SB1-0

BSCD GTIC 1 5.9F03.SB1-0

BSCC CSB050 Hotlink 1)ETPT11-0

BSCD_4509 ETC 3 2.3F06.SB1-1

BSCD GTIC 1 5.9F03.SB1-1

BSCC CSB050 Hotlink 1)ETPT11-0

BSCD_4510 ETC 2 2.0F06.SB1-0

BSCD GTIC 1 5.9F03.SB2-0

BSCC CSB052 Hotlink 1)ETPT 3-0

BSCD_4511 ETC 2 2.0F06.SB1-1

BSCD GTIC 1 5.9F03.SB2-1

BSCC CSB052 Hotlink 1)ETPT 3-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETPT

in this slot(s).

12.1.2 Create HW configuration

Create cartridges if not exist (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet)

GTIC-0 cartridge:ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

GTIC-1 cartridge: ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 cartridge: ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 cartridge: ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 cartridge: ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 cartridge: ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

Create ETPT functional unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet.ZWTU:ETPT,0,0:1A5-6;ZWTU:ETPT,1,0:1A5-6;

For BSC 3i 2000/Upgraded Flexi Double cabinetZWTU:ETPT,3,0:1B2-0;ZWTU:ETPT,11,0:1B2-3;ZWTU:ETPT,4,0:1B2-6;ZWTU:ETPT,5,0:1B2-6;ZWTU:ETPT,12,0:1B2-9;ZWTU:ETPT,13,0:1B2-9;

Page 144: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

144 (270)

Create ETPT plug-in unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000 / Upgraded Flexi Single cabinet.ZWTP:ETPT,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31,ETPPS,8,448&&511,TSL,0&&31;ZWTP:ETPT,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31,ETPPS,8,1792&&1855,TSL,0&&31;

For BSC 3i 2000 / Upgraded Flexi Double cabinet.ZWTP:ETPT,3,0:ETP,0,6::ETPCS,8,1664&&1727,TSL,0&&31,ETPPS,8,1728&&1791,TSL,0&&31;ZWTP:ETPT,11,0:ETP,0,6::ETPCS,8,320&&383,TSL,0&&31,ETPPS,8,448&&511,TSL,0&&31;ZWTP:ETPT,4,0:ETP,0,1::ETPCS,8,64&&127,TSL,0&&31,ETPPS,8,192&&255,TSL,0&&31;ZWTP:ETPT,5,0:ETP,0,6::ETPCS,8,1088&&1151,TSL,0&&31,ETPPS,8,1216&&1279,TSL,0&&31;ZWTP:ETPT,12,0:ETP,0,1::ETPCS,8,1856&&1919,TSL,0&&31,ETPPS,8,1792&&1855,TSL,0&&31;ZWTP:ETPT,13,0:ETP,0,6::ETPCS,8,1600&&1663,TSL,0&&31,ETPPS,8,1344&&1407,TSL,0&&31;

Note:For legacy A-interface: Hotlinks are connected from port 0&1 to GSWs. ETPCS functionality is created in plugin unit to support legacy A interface.For A over IP: Traffic will be routed though EEP interface created (via ETPA card).For PS via PCU2_E cards: No separate PCMs are required. This will use PEPeth link created in ETP cards tocommunicate with PCU2_E cards in BCSU.For PS via PCU2_D cards: Hotlinks are connected from port 2&2 to GSWs. ETPPS functionality is created inplug in unit to support PS calls via PCU2_D cards(PEP HDLC link).This will support CS calls in (A over IP,A over TDM) and PS calls if PCU2_E or PCU2_D cards are used inBSCs.

Connect functional unitsZWUC:ETPT,<pair_number>,<unit_index>:ETP,0:IF=ABIS:;

Create ETS2 functional unit (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinetSTMU-14 for ETPT 0-0 and ETPT 1-0ZWTU:STMU,14:1A5-6;

For BSC 3i 2000/Upgraded Flexi Double cabinet.STMU-20 for ETPT 11-0 and ETPT 3-0ZWTU:STMU,20:1A5-9;

STMU-22 for ETPT 13-0 and ETPT 5-0ZWTU:STMU,22:1A5-9;

STMU-6 for ETPT 12-0 and ETPT 4-0ZWTU:STMU,6:1A5-6;

Create ETS2 plug-in unit (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinetSTMU-14 for ETPT 0-0 and ETPT 1-0ZWTP:STMU,14:ETS2,0,8::LAPD,8,643,TSL,16&&31:;

For BSC 3i 2000/Upgraded Flexi Double cabinet.STMU-20 for ETPT 11-0 and ETPT 3-0 ZWTP:STMU,20:ETS2,0,3::LAPD,8,897,TSL,0&&15:;

STMU-22 for ETPT 13-0 and ETPT 5-0 ZWTP:STMU,22:ETS2,0,4::LAPD,8,897,TSL,16&&31:;

STMU-6 for ETPT 12-0 and ETPT 4-0 ZWTP:STMU,6:ETS2,0,4::LAPD,8,641,TSL,16&&31:;

Page 145: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

145 (270)

Create ETs functional units in ETS2, If ETSI

For ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet.

For ini BSC3i 1000/Upgraded Flexi Single cabinet

For ETPT 1-0 (ET creation for STMU-14,IF=0)ZWTU:ET,1856&&1918:1A5-6:UNIT=STMU,IND=14,IF=0:;

For ETPT 0-0 (ET creation for STMU-14,IF=1)ZWTU:ET,320&&382:1A5-6:UNIT=STMU,IND=14,IF=1:;

For ini BSC3i 2000/Upgraded Flexi double cabinet.

For ETPT 11-0 (ET creation for STMU-20,IF=0)ZWTU:ET,320&&382:1A5-9:UNIT=STMU,IND=20,IF=0:;

For ETPT 3-0 (ET creation for STMU-20,IF=1)ZWTU:ET,1664&&1726:1A5-9:UNIT=STMU,IND=20,IF=1:;

For ETPT 13-0 (ET creation for STMU-22,IF=0)ZWTU:ET,1600&&1662:1A5-9:UNIT=STMU,IND=22,IF=0:;

For ETPT 5-0 (ET creation for STMU-22,IF=1)ZWTU:ET, 1088&&1150:1A5-9:UNIT=STMU,IND=22,IF=1:;

For ETPT 12-0 (ET creation for STMU-6,IF=0)ZWTU:ET,1856&&1918:1A5-6:UNIT=STMU,IND=6,IF=0:;

For ETPT 4-0 (ET creation for STMU-6,IF=1)ZWTU:ET,64&&126:1A5-6:UNIT=STMU,IND=6,IF=1:;

Create ETs functional units in ETS2, If ANSI

For ini BSC3i 1000/Upgraded Flexi Single cabinet

For ETPT 1-0 (ET creation for STMU-14,IF=0)ZWTU:ET, 3140&&3223:1A5-6:UNIT=STMU,IND=14,IF=0:;

For ETPT 0-0 (ET creation for STMU-14,IF=1)ZWTU:ET, 2216&&2299:1A5-6:UNIT=STMU,IND=14,IF=1:;

For ini BSC3i 2000/Upgraded Flexi double cabinet

For ETPT 11-0 (ET creation for STMU-20,IF=0)ZWTU:ET,2216&&2299:1A5-9:UNIT=STMU,IND=20,IF=0:;

For ETPT 3-0 (ET creation for STMU-20,IF=1)ZWTU:ET,2888&&2971:1A5-9:UNIT=STMU,IND=20,IF=1:;

For ETPT 13-0 (ET creation for STMU-22,IF=0)ZWTU:ET, 2804&&2887:1A5-9:UNIT=STMU,IND=22,IF=0:;

Page 146: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

146 (270)

For ETPT 5-0 (ET creation for STMU-22,IF=1)ZWTU:ET, 2384&&2467:1A5-9:UNIT=STMU,IND=22,IF=1:;

For ETPT 12-0 (ET creation for STMU-6,IF=0)ZWTU:ET, 3140&&3223:1A5-6:UNIT=STMU,IND=6,IF=0:;

For ETPT 4-0 (ET creation for STMU-6,IF=1)ZWTU:ET,2048&&2131:1A5-6:UNIT=STMU,IND=6,IF=1:;

For ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

Create ETs Plug in units in ETS2, If ETSI

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 1-0 (ET creation for STMU-14,IF=0) ZWTP:ET,1856&&1918:ETS2,0,8::GENERAL,8,1856&&1918,NO:;

For ETPT 0-0 (ET creation for STMU-14,IF=1) ZWTP:ET,320&&382:ETS2,0,8::GENERAL,8,320&&382,NO:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 11-0 (ET creation for STMU-20,IF=0)ZWTP:ET, 320&&382,:ETS2,0,3::GENERAL,8, 320&&382,NO:;

For ETPT 3-0 (ET creation for STMU-20,IF=1)ZWTP:ET, 1664&&1726:ETS2,0,3::GENERAL,8,1664&&1726,NO:;

For ETPT 13-0 (ET creation for STMU-22,IF=0)ZWTP:ET, 1600&&1662:ETS2,0,4::GENERAL,8,1600&&1662,NO:;

For ETPT 5-0 (ET creation for STMU-22,IF=1)ZWTP:ET, 1088&&1150:ETS2,0,4::GENERAL,8,1088&&1150,NO:;

For ETPT 12-0 (ET creation for STMU-6,IF=0)ZWTP:ET, 1856&&1918:ETS2,0,4::GENERAL,8,1856&&1918,NO:;

For ETPT 4-0 (ET creation for STMU-6,IF=1)ZWTP:ET, 64&&126:ETS2,0,4::GENERAL,8, 64&&126,NO:;

Create ETs Plug in units in ETS2, If ANSI

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 1-0 (ET creation for STMU-14,IF=0)ZWTP:ET, 3140&&3223:ETS2,0,8::GENERAL,8, 3140&&3223,NO:;

For ETPT 0-0 (ET creation for STMU-14,IF=1)ZWTP:ET, 2216&&2299:ETS2,0,8::GENERAL,8, 2216&&2299,NO:;

For BSC 3i 2000/Upgarded Flexi Double cabinet

Page 147: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

147 (270)

For ETPT 11-0 (ET creation for STMU-20,IF=0)ZWTP:ET, 2216&&2299,:ETS2,0,3::GENERAL,8, 2216&&2299,NO:;

For ETPT 3-0 (ET creation for STMU-20,IF=1)ZWTP:ET, 2888&&2971:ETS2,0,3::GENERAL,8, 2888&&2971,NO:;

For ETPT 13-0 (ET creation for STMU-22,IF=0)ZWTP:ET, 2804&&2887:ETS2,0,4::GENERAL,8, 2804&&2887,NO:;

For ETPT 5-0 (ET creation for STMU-22,IF=1)ZWTP:ET, 2384&&2467 :ETS2,0,4::GENERAL,8, 2384&&2467,NO:;

For ETPT 12-0 (ET creation for STMU-6,IF=0)ZWTP:ET, 3140&&3223:ETS2,0,4::GENERAL,8, 3140&&3223,NO:;

For ETPT 4-0 (ET creation for STMU-6,IF=1)ZWTP:ET, 2048&&2131:ETS2,0,4::GENERAL,8, 2048&&2131,NO:;

Connect STMUs

For ini BSC 3i 1000/Upgraded Flexi Single cabinet

ZWUC:STMU,14:ETS2,0::BCSU,<index>:;

For ini BSC 3i 2000/Upgraded Flexi Double cabinet

ZWUC:STMU,20:ETS2,0::BCSU,<index>:;ZWUC:STMU,22:ETS2,0::BCSU,<index>:;ZWUC:STMU,6:ETS2,0::BCSU,<index>:;

Connect ETs, IF ETSI

For BSC 3i 1000/Upgraded Flexi Single cabinet

ZWUC:ET,1856&&1918:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET,320&&382:ETS2,0:IF=ABIS:BCSU,<index>;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ZWUC:ET,320&&382:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET,1664&&1726:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET,1600&&1662:ETS2,0:IF=ABIS:BCSU,,index>;ZWUC:ET,1088&&1150:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET,1856&&1918:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET,64&&126:ETS2,0:IF=ABIS:BCSU,<index>;

Connect ETs, IF ANSIFor BSC 3i 1000/Upgraded Flexi Single cabinet.

ZWUC:ET, 3140&&3223:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET, 2216&&2299:ETS2,0:IF=ABIS:BCSU,<index>;

For BSC 3i 2000/Upgraded Flexi Double cabinet.

ZWUC:ET, 2216&&2299:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET, 2888&&2971:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET, 2804&&2887:ETS2,0:IF=ABIS:BCSU,<index>;

Page 148: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

148 (270)

ZWUC:ET, 2384&&2467:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET, 3140&&3223:ETS2,0:IF=ABIS:BCSU,<index>;ZWUC:ET, 2048&&2131:ETS2,0:IF=ABIS:BCSU,<index>;

Create protection groups.(For BSC3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single Cabinet

For ETPT 0-0ZYWC:,,<BI/UNI>,<APS or MSP>:58,59;

For ETPT 1-0ZYWC:,,<BI/UNI>,<APS or MSP>:56,57;

For BSC 3i 2000 ( 2cabinet)

For ETPT 3-0ZYWC:,,<BI/UNI>,<APS or MSP>:82,83;

For ETPT 4-0ZYWC:,,<BI/UNI>,<APS or MSP>:26,27;

For ETPT 5-0ZYWC:,,<BI/UNI>,<APS or MSP>:90,91;

For ETPT 11-0ZYWC:,,<BI/UNI>,<APS or MSP>:80,81;

For ETPT 12-0ZYWC:,,<BI/UNI>,<APS or MSP>:24,25;

For ETPT 13-0ZYWC:,,<BI/UNI>,<APS or MSP>:88,89;

For ANSI-APS and ETSI-MSP.

Note: This command is required only if PCMs are created in ETP plug in units.

Connect hotlink ports

ZWTA:GSW,0:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:GSW,1:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:STMU,<Unit_index>:ETS2,<PIU_Index>:HOTLINK,<Port_Index>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

For BSC 3i 1000/Upgraded Flexi Single cabinet

ETPT 0-0ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPT,0,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPT,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPT,0,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPT,0,0:ETP,0:HOTLINK,3:;

Page 149: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

149 (270)

ZWTA:STMU,14:ETS2,0:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,4:;ZWTA:STMU,14:ETS2,0:HOTLINK,3:ETPT,0,0:ETP,0:HOTLINK,5:;

ETPT 1-0ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPT,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPT,1,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,6:ETPT,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,6:ETPT,1,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,4:;ZWTA:STMU,14:ETS2,0:HOTLINK,1:ETPT,1,0:ETP,0:HOTLINK,5:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ETPT 3-0ZWTA:GSW,0:SW256B,6:HOTLINK,4:ETPT,3,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,4:ETPT,3,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,6:ETPT,3,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,6:HOTLINK,6:ETPT,3,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,20:ETS2,0:HOTLINK,2:ETPT,3,0:ETP,0:HOTLINK,4:;ZWTA:STMU,20:ETS2,0:HOTLINK,3:ETPT,3,0:ETP,0:HOTLINK,5:;

ETPT 11-0

ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPT,11,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPT,11,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPT,11,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPT,11,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,20:ETS2,0:HOTLINK,0:ETPT,11,0:ETP,0:HOTLINK,4:;ZWTA:STMU,20:ETS2,0:HOTLINK,1:ETPT,11,0:ETP,0:HOTLINK,5:;

ETPT 5-0ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPT,5,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPT,5,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPT,5,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPT,5,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,22:ETS2,0:HOTLINK,2:ETPT,5,0:ETP,0:HOTLINK,4:;ZWTA:STMU,22:ETS2,0:HOTLINK,3:ETPT,5,0:ETP,0:HOTLINK,5:;

ETPT 4-0ZWTA:GSW,0:SW256B,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,6:ETPT,4,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,6:ETPT,4,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,4:;ZWTA:STMU,6:ETS2,0:HOTLINK,3:ETPT,4,0:ETP,0:HOTLINK,5:;

Page 150: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

150 (270)

ETPT 13-0ZWTA:GSW,0:SW256B,6:HOTLINK,2:ETPT,13,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,2:ETPT,13,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,5:HOTLINK,2:ETPT,13,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,2:ETPT,13,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,22:ETS2,0:HOTLINK,0:ETPT,13,0:ETP,0:HOTLINK,4:;ZWTA:STMU,22:ETS2,0:HOTLINK,1:ETPT,13,0:ETP,0:HOTLINK,5:;

ETPT 12-0ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPT,12,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPT,12,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPT,12,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPT,12,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,0:ETPT,12,0:ETP,0:HOTLINK,4:;ZWTA:STMU,6:ETS2,0:HOTLINK,1:ETPT,12,0:ETP,0:HOTLINK,5:;

Configure ETPSIG-M TCP/IP stack configuration for ETPT (SE-NH).ZQRA:ETPT, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPT, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPT, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M IP address with parameters PDM to ETPT BOND0 interface.ZQRN:ETPT,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Create ETPSIG-C IP addressZQRN:ETPT,<pair_number>,>unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSG-CZD2C:M:BCSU,<unit_index>:ETPT<pair_number>,<unit_index>:;ZD2C:C,NOR:BCSU,<unit_index>:ETPT,<pair_umber>,<unit_index>:;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units

Create EL0 IP address to ETPTZQRA:ETPT,<pair_number>,<unit_index>::EL0::UP;ZQRN:ETPT,<pair_number>,<unit_index>::EL0,:"<ip_address>",<network_mask_length>,P,:;

Create EEP interface for traffic between ETPT and ETPAZQRA:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Note: EEP interface creation is required only if A over IP is used.

Note: In case of BSC 3i 1000/2000 or Upgraded flexi Single cabinet/Double cabinet the following pop upwill occur in macro.

Page 151: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

151 (270)

Select the required application to proceed further.

Note: Create the PEP link to ETPGID 0 first if you want to get the ETP object ID for the ETPGID to match inNetAct.

Create PEP interface if PCU2-E’s are in useZQRA:ETPT, <pair_number>,<unit_index>::<PEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPT,<pair_number>,<unit_index>::<PEP_VLAN>,:”<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPT, <pair_number>,<unit_index>::<PEP_VLAN>:"<ip_address>":TAG,"PEP":;

Create IN0 interface (Internal Octeon-DSP interface)ZQRA:ETPT,<pair number>,<unit index>:IN0::UP;ZQRN:ETPT,<pair number>,<unitindex>::IN0”<ipaddress>”,<NETWORK_MASK_LENGTH>,P,I::;

Create route from BCSUs to ETPT.

Route is for OMU/TRXSIG from BCSUs to BTSs.ETPT is the GW towards BTS.ZQKC:BCSU,<Index>::"< Network IP address >",<Sub net mask> :"<ETPT (IL0/IL1) IP address for C-Plane>":LOG:;

Change state of ETPT to TE-EXZUSC:ETPT,<pair_number>,<unit_index>:SE;

ZUSC:ETPT,<pair_number>,<unit_index>:TE;

12.1.3 Check Plug-in unit software

Note: The flashing does not succeed if the username and password in the ETP card does not matchthe BSC’s username & password. Refer Appendix 6 to see an example how to update the username &password via ETP service terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Page 152: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

152 (270)

Check the CBUHAN version in BSC package.ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Page 153: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

153 (270)

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Page 154: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

154 (270)

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

12.1.4 Diagnostic

Run diagnostic to the ETPTZUDU:ETPT,<pair number>,<unit index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPT to WO-EX ZUSC:ETPT,<pair number>,<unit index>:WO;

12.1.5 STMU s to WO-EX state

ZUSC:STMU,<STMU index>,SE;ZUSC:STMU,<STMU index>,TE;

Check current boot SW version in STMU and compare it to version that is found from the active SW packageZWDI:UT=STMU,UI=<STMU_index>;

If boot SW versions do not match, these must be upgraded.

Update can be done with following command:ZWDR:UT=STMU,UI=<STMU_index>;

Note! This can take from one unit 40-60 minutes. Do not remove the cards or cause power restart whileupdating the boot SW, because the SW can corrupt and only way to recover is to send the PIU to HWS.

Page 155: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

155 (270)

During updating flash memory of ETS2 all connections will be prevented through that Plug-in unit.

Run diagnostic to STMU ZUDU:STMU,<STMU index>::;

Change STMU to WO-EXZUSC:STMU,<STMU index>,WO;

12.1.6 Check PCU configuration

If Packet Abis interface is also used in PS traffic check PCU configuration. PCU2-D or PCU2-E must be created tothe PCUPAB function that it can carry Packet Abis PS data.

For PCU2_E cards PEP interface creation is required to support PEP Eth link. These creations are mentioned inthe below document.

PCU configuration can be checked with following command:ZWTI:BCSU,<unit_index>;

Use “BSCPCU HW implementation for PS traffic” procedure if PCU configurations need to change.

ETP- PCU connection.ZESK:ETPT,<pair number>:BCSU,<index>:PCU,<index>:;

Note: This is required for both PCU2_E and PCU2_D cards.

12.2 Creation of ETPT unit with hardware protection

Check the source configuration for overlapping PCM areas.

Note!Macro asks in this point redundancy type and Plug-in Unit location. After that macro check possibleunit/PCM overlapping.

If there is overlapping PCM areas move or remove resources from them. Macro will remove unit and Plug-in Unitsautomatically after needed recourses are moved or removed.

Note: - Refer Appendix 2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

12.2.1 Install Plug-in units, terminators and cables

12.2.1.1 Terminators and setting modules

For BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet

For BSC3i 1000/Upgraded Flexi Single cabinetPosition ID Name FU Cabinet Use Note

ETPTINDEX

5.6B 014E

C108585 ADMOD01 GTIC 0 BSCC For ETPTETSI

1) ETPT 0-0

Page 156: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

156 (270)

5.6B 014E

C108704 ADMOD17 GTIC 0 BSCC For ETPTANSI

2) ETPT 0-0

5.6B 064E

C108585 ADMOD01 GTIC 0 BSCC For ETPTETSI

1) ETPT 1-0

5.6B 064E

C108704 ADMOD17 GTIC 0 BSCC For ETPTANSI

2) ETPT 1-0

5.9B 014E

C108585 ADMOD01 GTIC 1 BSCC For ETPTETSI

1) ETPT 0-1

5.9B 014E

C108704 ADMOD17 GTIC 1 BSCC For ETPTANSI

2) ETPT 0-1

5.9B 064E

C108585 ADMOD01 GTIC 1 BSCC For ETPTETSI

1) ETPT 1-1

5.9B 064E

C108704 ADMOD17 GTIC 1 BSCC For ETPTANSI

2) ETPT 1-1

5.6B09.2J

C101501 CABID1A GTIC 0 BSCC Cabinetidentification

ETPT 0-0/ ETPT1-0

5.6B09.2L

C101557 CARID53 GTIC 0 BSCC Cartridgeidentification

ETPT 0-0/ ETPT1-0

5.9B09.2J

C101501 CABID1A GTIC 1 BSCC Cabinetidentification

ETPT 0-1/ ETPT1-1

5.9B09.2L

C101558 CARID54 GTIC 1 BSCC Cartridgeidentification

ETPT 0-1/ ETPT1-1

Notes:

1) Install when ETP plug-in unit is used as ETPT ETSI in this slot.2) Install when ETP PIU is used ETPT ANSI in this slot

For BSC 3i 2000/Upgraded Flexi Double cabinet

Position ID Name FU Cabinet Use Note ETPTINDEX

5.6B 014E

C108585 ADMOD01 GTIC 0 BSCC For ETPTETSI

1) ETPT 0-1

5.6B 014E

C108704 ADMOD17 GTIC 0 BSCC For ETPTANSI

2) ETPT 0-1

5.6B 064E

C108585 ADMOD01 GTIC 0 BSCC For ETPTETSI

1) ETPT 1-1

5.6B 064E

C108704 ADMOD17 GTIC 0 BSCC For ETPTANSI

2) ETPT 1-1

5.9B 014E

C108585 ADMOD01 GTIC 1 BSCC For ETPTETSI

1) ETPT 0-0

5.9B 014E

C108704 ADMOD17 GTIC 1 BSCC For ETPTANSI

2) ETPT 0-0

5.9B 064E

C108585 ADMOD01 GTIC 1 BSCC For ETPTETSI

1) ETPT 1-0

5.9B 064E

C108704 ADMOD17 GTIC 1 BSCC For ETPTANSI

2) ETPT 1-0

Page 157: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

157 (270)

2.0B 014E

C108585 ADMOD01 ETC 2 BSCD For ETPTETSI

1) ETPT 2-1

2.0B 014E

C108704 ADMOD17 ETC 2 BSCD For ETPTANSI

2) ETPT 2-1

2.0B 064E

C108585 ADMOD01 ETC 2 BSCD For ETPTETSI

1) ETPT 3-0

2.0B 064E

C108704 ADMOD17 ETC 2 BSCD For ETPTANSI

2) ETPT 3-0

2.3B 014E

C108585 ADMOD01 ETC 3 BSCD For ETPTETSI

1) ETPT 2-0

2.3B 014E

C108704 ADMOD17 ETC 3 BSCD For ETPTANSI

2) ETPT 2-0

2.3B 064E

C108585 ADMOD01 ETC 3 BSCD For ETPTETSI

1) ETPT 3-1

2.3B 064E

C108704 ADMOD17 ETC 3 BSCD For ETPTANSI

2) ETPT 3-1

2.6B 014E

C108585 ADMOD01 ETC 4 BSCD For ETPTETSI

1) ETPT 4-0

2.6B 014E

C108704 ADMOD17 ETC 4 BSCD For ETPTANSI

2) ETPT 4-0

2.6B 064E

C108585 ADMOD01 ETC 4 BSCD For ETPTETSI

1) ETPT 5-0

2.6B 064E

C108704 ADMOD17 ETC 4 BSCD For ETPTANSI

2) ETPT 5-0

2.9B 014E

C108585 ADMOD01 ETC 5 BSCD For ETPTETSI

1) ETPT 4-1

2.9B 014E

C108704 ADMOD17 ETC 5 BSCD For ETPTANSI

2) ETPT 4-1

2.9B 064E

C108585 ADMOD01 ETC 5 BSCD For ETPTETSI

1) ETPT 5-1

2.9B 064E

C108704 ADMOD17 ETC 5 BSCD For ETPTANSI

2) ETPT 5-1

2.0B09.2J

C101502 CABID1B ETC 2 BSCD Cabinetidentification

ETPT 2-1/ETPT3-0

2.0B09.2L

C101535 CARID20 ETC 2 BSCD Cartridgeidentification

ETPT 2-1/ETPT3-0

2.3B09.2J

C101502 CABID1B ETC 3 BSCD Cabinetidentification

ETPT 2-0/ETPT3-1

2.3B09.2L

C101536 CARID21 ETC 3 BSCD Cartridgeidentification

ETPT 2-0/ETPT3-1

2.6B09.2J

C101502 CABID1B ETC 4 BSCD Cabinetidentification

ETPT 4-0/ ETPT5-0

2.6B09.2L

C101538 CARID23 ETC 4 BSCD Cartridgeidentification

ETPT 4-0/ ETPT5-0

2.9B09.2J

C101502 CABID1B ETC 5 BSCD Cabinetidentification

ETPT 4-1/ ETPT5-1

Page 158: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

158 (270)

2.9B09.2L

C101539 CARID24 ETC 5 BSCD Cartridgeidentification

ETPT 4-1/ ETPT5-1

Notes:

1) Install when ETP plug-in unit is used as ETPT ETSI in this slot.2) Install when ETP PIU is used ETPT ANSI in this slot

12.2.1.2 Plug-in unit installation

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinet.

CartridgeSGC1Cposition

Unit Cartridge/ Slots

ETPT groupindex

Mate ETS2/SET Cartridge / slot /Interfaceof mate ETS2

5.6 GTIC-0 1 0-0 STMU 14/ SET 58 GTIC 0 / 8 / SB2

5.9 GTIC-1 1 0-1 STMU 15/ SET 62 GTIC 1 / 8 / SB2

5.6 GTIC-0 6 1-0 STMU 14/ SET 56 GTIC 0/ 8 / SB1

5.9 GTIC-1 6 1-1 STMU 15/ SET 60 GTIC 1 / 8 / SB1

Note:Check Appendix 5 for ETP strappings and STMU strappings.

For BSC 3i 2000/Upgraded Flexi Double cabinet.

CartridgeSGC1Cposition

Unit Cartridge/ Slots

ETPTgroupindex

Mate ETS2/SET Cartridge / slot /Interface

Page 159: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

159 (270)

5.9 GTIC-1 1 0-0STMU 15/ SET62 GTIC 1 / 8 / SB2

5.6 GTIC-0 1 0-1STMU 14/ SET58 GTIC 0 / 8 / SB2

5.9 GTIC-1 6 1-0STMU 15/ SET60 GTIC 1 / 8 / SB1

5.6 GTIC-0 6 1-1STMU 14/ SET56 GTIC 0 / 8 / SB1

2.3 ETC-3 1 2-0 STMU 5/SET 22 GTIC 1 / 3 / SB2

2.0 ETC-2 1 2-1 STMU 4/SET 18 GTIC 0/3/SB2

2.0 ETC-2 6 3-0 STMU 4/SET 16 GTIC0 /3/SB1

2.3 ETC-3 6 3-1 STMU 5/SET 20 GTIC 1/3/SB1

2.6 ETC-4 1 4-0 STMU 6/SET 26 GTIC 0/4/SB2

2.9 ETC-5 1 4-1 STMU 7/SET 30 GTIC 1/4/SB2

2.6 ETC-4 6 5-0 STMU 6/SET 24 GTIC 0/4/SB1

2.9 ETC-5 6 5-1 STMU 7/SET 28 GTIC 1/4/SB1

Note: Check Appendix 5 for ETP strappings and STMU strappings.

Page 160: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

160 (270)

12.2.1.3 Cabling

12.2.1.3.1 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 SE-NH state

ZUSC:MCMU,0:SP; If neededZUSC:MCMU,0:TE;ZUSC:MCMU,0:SE;ZUSC:MCMU,0:SE;

ZUSC:EMB,0:SP;if neededZUSC:EMB,0:TE;ZUSC:EMB,0:SE;ZUSC:EMB,0:SE;

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

12.2.1.3.1.1 For initial BSC 3i 1000/2000

12.2.1.3.1.1.1 For BSC 3i 1000

Remove following cables if needed

Page 161: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

161 (270)

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 2)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 2)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2) 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2)

Move and reconnect or add following cables if required

Equipping Cable from Cable to

No

OldCab/ Old FU/ Old

Position/OldCab/ Old FU/ Old

Position/Type Use Note

ETPTindex

NewCab

NewFU

NewPosition

NewCab New FU New

Position

BSCC_714 BSCC GTIC 0

5.6F02.SB1-0 BSCC GSW2KB

0

1.0F02.SB2-0 CSB031 2)

ETPT 0-0

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC 0

5.6F02.SB2-0 BSCC GSW2KB

0

1.0F02.SB4-0 CSB030 2)

ETPT 0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC 15.9F01.SB1-0 BSCC GSW2KB

0

1.0F06.SB2-0 CSB027 1)

ETPT 1-0GTIC 0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC 15.9F01.SB2-0 BSCC GSW2KB

0

1.0F07.SB2-0 CSB027 1)

ETPT 1-0GTIC 0

5.6F07.SB3-0

1.0F08.SB1-1

BSCC_730 BSCC GTIC 1

5.9F02.SB1-0 BSCC GSW2KB

0

1.0F07.SB3-0 CSB027 1)

ETPT 1-1

5.9F07.SB2-0

1.0F08.SB2-0

Page 162: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

162 (270)

BSCC_731 BSCC GTIC 1

5.9F02.SB2-0 BSCC GSW2KB

0

1.0F07.SB4-0 CSB027 1)

ETPT 1-1

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2KB

0

1.0F01.SB2-0 CSB031 2)

ETPT 0-1GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC 05.6F01.SB2-0 BSCC GSW2KB

0

1.0F01.SB4-0 CSB030 2)

ETPT 0-1GTIC 1

5.9F02.SB3-0

1.0F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Add needed ETPLAN cables from LANU-0 to required tracks.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use ETPindex

BSCC_4400 LANU 0 5.0B05.2E GTIC 0 5.6B

06.4G CHES009 ETPLAN ETPT1-0

BSCC_4402 LANU 0 5.0B05.2J GTIC 0 5.6B

01.4G CHES008 ETPLAN ETPT0-0

BSCC_4403 LANU 0 5.0B05.2L GTIC 1 5.9B

06.4G CHES011 ETPLAN ETPT1-1

BSCC_4405 LANU 0 5.0B05.2P GTIC 1 5.9B

01.4G CHES010 ETPLAN ETPT0-1

12.2.1.3.1.1.2 For BSC 3i 2000

Remove following cables if needed

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_718 GTIC 0 5.6F03.SB1-

GSW2KB0

1.0F05.SB2- CSB029 Hotlink 2)

Page 163: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

163 (270)

0 0

BSCC_719 GTIC 05.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 2)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 3)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 3)

BSCC_734 GTIC 15.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 4)

BSCC_735 GTIC 15.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 4)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add following cables if required

Equipping Cable from Cable to

No

OldCab/ Old FU/ Old

Position/OldCab/ Old FU/ Old

Position/Type Use Note

ETPTIndex

NewCab

NewFU

NewPosition

NewCab New FU New

Position

BSCC_730 BSCC GTIC 1

5.9F02.SB1-0 BSCC GSW2KB

0

1.0F07.SB3-0 CSB027 1)

ETPT 1-0

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCC GTIC 1

5.9F02.SB2-0 BSCC GSW2KB

0

1.0F07.SB4-0 CSB027 1)

ETPT 1-0

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2KB

0

1.0F01.SB2-0 CSB031 2)

ETPT 0-0GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2KB

0

1.0F01.SB2-0 CSB031 2)

ETPT 0-0GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_714 BSCC GTIC 05.6F02.SB1-0

BSCC GSW2KB0

1.0F02.SB2-0

CSB031 2)ETPT 0-1

Page 164: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

164 (270)

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCC GTIC 0

5.6F02.SB2-0 BSCC GSW2KB

0

1.0F02.SB4-0 CSB030 2)

ETPT 0-1

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC 15.9F01.SB1-0 BSCC GSW2KB

0

1.0F06.SB2-0 CSB027 1)

ETPT 1-1GTIC 0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC 15.9F01.SB2-0 BSCC GSW2KB

0

1.0F07.SB2-0 CSB027 1)

ETPT 1-1GTIC 0

5.6F07.SB3-0

1.0F08.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETP (T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07is taken in use.2) These Hotlinks are moved in a situation where ETP (T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02is taken in use.Equipping

Cable from Cable to

No Old Old FU OldPosition

NewFU

NewPosition

OLd OldFU

OldPosition

Type Use Note ETPTIndex

Cab Cab

BSCC_4372

BSCC

GSW2KB 0

1.0F02.SB4-0

GSW2KB 0

1.0F07.SB4-1

BSCD

ETC 3

2.3F07.SB3-0

CSB024

Hotlink

ETPT 3-1

BSCC_4360

BSCC

GSW2KB 0

1.0F02.SB2-0

GSW2KB 0

1.0F07.SB3-1

BSCD

ETC 3

2.3F07.SB2-0

CSB027

Hotlink

3) ETPT 3-1

BSCC_4356

BSCC

GSW2KB 0

1.0F07.SB2-0

GSW2KB 0

1.0F05.SB2-1

BSCD

ETC 5

2.9F07.SB2-0

CSB029

Hotlink

1) ETPT 5-1

BSCC_4368

BSCC

GSW2KB 0

1.0F06.SB2-0

GSW2KB 0

1.0F05.SB4-1

BSCD

ETC 5

2.9F07SB3-0

CSB029

Hotlink

1) ETPT 5-1

BSCC_4358

BSCC

GSW2KB 0

1.0F08.SB2-0

GSW2KB 0

1.0F01.SB2-1

BSCD

ETC 5

2.9F02.SB2-0

CSB027

Hotlink

2) ETPT 4-1

BSCC_4370

BSCC

GSW2KB 0

1.0F08.SB1-0

GSW2KB 0

1.0F01.SB4-1

BSCD

ETC 5

2.9F02.SB3-0

CSB029

Hotlink

2) ETPT 4-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.

Page 165: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

165 (270)

3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-0 to required tracks, Hotlinks from GSW,0 to required tracks.

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FU Position Cabinet Type Use NoteETPTIndex

BSCC_4300LANU0

5.0B05.1A BSCC ETC 2

2.0B01.4G BSCD CHES045 ETPLAN

ETPT2-1

BSCC_4302LANU0

5.0B05.1E BSCC ETC 2

2.0B06.4G BSCD CHES044 ETPLAN

ETPT3-0

BSCC_4303LANU0

5.0B05.1G BSCC ETC 3

2.3B01.4G BSCD CHES043 ETPLAN

ETPT2-0

BSCC_4305LANU0

5.0B05.1L BSCC ETC 3

2.3B06.4G BSCD CHES042 ETPLAN

ETPT3-1

BSCC_4306LANU0

5.0B05.1N BSCC ETC 4

2.6B01.4G BSCD CHES042 ETPLAN

ETPT4-0

BSCC_4307LANU0

5.0B05.1P BSCC ETC 4

2.6B06.4G BSCD CHES041 ETPLAN

ETPT5-0

BSCC_4308LANU0

5.0B05.1R BSCC ETC 5

2.9B01.4G BSCD CHES041 ETPLAN

ETPT4-1

BSCC_4309LANU0

5.0B05.2C BSCC ETC 5

2.9B06.4G BSCD CHES040 ETPLAN

ETPT5-1

BSCD_4350ETC4

2.6F07.SB2-0 BSCD

GSW2KB0

1.0F05.SB2-0 BSCC CSB027 Hotlink 1)

ETPT5-0

BSCD_4352ETC4

2.6F02.SB2-0 BSCD

GSW2KB0

1.0F01.SB2-0 BSCC CSB027 Hotlink 1)

ETPT4-0

BSCD_4362ETC4

2.6F07.SB3-0 BSCD

GSW2KB0

1.0F05.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPT5-0

BSCD_4364ETC4

2.6F02.SB3-0 BSCD

GSW2KB0

1.0F01.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPT4-0

BSCD_4354ETC2

2.0F07.SB2-0 BSCD

GSW2KB0

1.0F07.SB3-0 BSCC CSB022 Hotlink 1)

ETPT3-0

BSCD_4366ETC2

2.0F07.SB3-0 BSCD

GSW2KB0

1.0F07.SB4-0 BSCC CSB021 Hotlink 1), 2)

ETPT3-0

BSCD_4620ETC3

2.3F02.SB2-0 BSCD

GSW2KB0

1.0F07.SB2-0 BSCC CSB026 Hotlink

3)Default

ETPT2-0

BSCD_4624ETC3

2.3F02.SB3-0 BSCD

GSW2KB0

1.0F06.SB2-0 BSCC CSB026 Hotlink 3)

ETPT2-0

BSCD_4622ETC2

2.0F02.SB2-0 BSCD

GSW2KB0

1.0F07.SB2-1 BSCC CSB026 Hotlink 3)

ETPT2-1

BSCD_4626 ETC 2.0F BSCD GSW2KB 1.0F BSCC CSB026 Hotlink 3) ETPT

Page 166: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

166 (270)

2 02.SB3-0 0 06.SB2-1

2-1

BSCC_4400LANU0

5.0B05.2E BSCC GTIC 0

5.6B06.4G BSCC CHES009 ETPLAN

ETPT1-1

BSCC_4402LANU0

5.0B05.2J BSCC GTIC 0

5.6B01.4G BSCC CHES008 ETPLAN

ETPT0-1

BSCC_4403LANU0

5.0B05.2L BSCC GTIC 1

5.9B06.4G BSCC CHES011 ETPLAN

ETPT1-0

BSCC_4405LANU0

5.0B05.2P BSCC GTIC 1

5.9B01.4G BSCC CHES010 ETPLAN

ETPT0-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s))2) These cables are not used, if no PCU2-D is equipped3) These Hotlink cables are added in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot01/02 is taken in use.

12.2.1.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.2.1.3.1.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if needed.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 0 5.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 0 5.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_730 GTIC 1 5.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 2)

BSCC_731 GTIC 1 5.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 2)

Notes: 1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1 (and 2). 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No

OldCab/ Old FU/ Old

Position/OldCab/ Old FU/ Old

Position/Type Use Note

ETPTindex

NewCab

NewFU

NewPosition

NewCab New FU New

Position

BSCC_714 BSCC GTIC 0

5.6F02.SB1-0 BSCC GSW2KB

0

1.0F02.SB2-0 CSB031 2)

ETPT 0-0

5.6F02.SB2-0

1.0F02.SB2-1

Page 167: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

167 (270)

BSCC_715 BSCC GTIC 0

5.6F02.SB2-0 BSCC GSW2KB

0

1.0F02.SB4-0 CSB030 2)

ETPT 0-0

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC 15.9F01.SB1-0 BSCC GSW2KB

0

1.0F06.SB2-0 CSB027 1)

ETPT 1-0GTIC 0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC 15.9F01.SB2-0 BSCC GSW2KB

0

1.0F07.SB2-0 CSB027 1)

ETPT 1-0GTIC 0

5.6F07.SB3-0

1.0F08.SB1-1

BSCC_730 BSCC GTIC 1

5.9F02.SB1-0 BSCC GSW2KB

0

1.0F07.SB3-0 CSB027 1)

ETPT 1-1

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCC GTIC 1

5.9F02.SB2-0 BSCC GSW2KB

0

1.0F07.SB4-0 CSB027 1)

ETPT 1-1

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC 05.6F01.SB1-0 BSCC GSW2KB

0

1.0F01.SB2-0 CSB031 2)

ETPT 0-1GTIC 1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC 05.6F01.SB2-0 BSCC GSW2KB

0

1.0F01.SB4-0 CSB030 2)

ETPT 0-1GTIC 1

5.9F02.SB3-0

1.0F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Add needed ETPLAN cables from LANU-0 to required tracks.

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4400 LANU 0 1.8B05.2G GTIC 0 5.6B

06.4G CHES023 ETPLAN ETPT 1-0

BSCC_4402 LANU 0 1.8B05.2L GTIC 0 5.6B

01.4G CHES024 ETPLAN ETPT 0-0

Page 168: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

168 (270)

BSCC_4403 LANU 0 1.8B05.2N GTIC 1 5.9B

06.4G CHES021 ETPLAN ETPT 1-1

BSCC_4405 LANU 0 1.8B05.2R GTIC 1 5.9B

01.4G CHES022 ETPLAN ETPT 0-1

12.2.1.3.1.2.2 For upgraded flexi BSC Double cabinet.

Remove cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_710 GTIC 05.6F01.SB1-0

GSW2KB0

1.0F01.SB2-0

CSB031 Hotlink 1)

BSCC_711 GTIC 05.6F01.SB2-0

GSW2KB0

1.0F01.SB4-0

CSB030 Hotlink 1)

BSCC_714 GTIC 05.6F02.SB1-0

GSW2KB0

1.0F02.SB2-0

CSB031 Hotlink 2)

BSCC_715 GTIC 05.6F02.SB2-0

GSW2KB0

1.0F02.SB4-0

CSB030 Hotlink 2)

BSCC_718 GTIC 05.6F03.SB1-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 3)

BSCC_719 GTIC 05.6F03.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 3)

BSCC_726 GTIC 15.9F01.SB1-0

GSW2KB0

1.0F06.SB2-0

CSB027 Hotlink 4)

BSCC_727 GTIC 15.9F01.SB2-0

GSW2KB0

1.0F07.SB2-0

CSB027 Hotlink 4)

BSCC_730 GTIC 15.9F02.SB1-0

GSW2KB0

1.0F07.SB3-0

CSB027 Hotlink 5)

BSCC_731 GTIC 15.9F02.SB2-0

GSW2KB0

1.0F07.SB4-0

CSB027 Hotlink 5)

BSCC_734 GTIC 15.9F03.SB1-0

GSW2KB0

1.0F08.SB1-0

CSB027 Hotlink 6)

BSCC_735 GTIC 15.9F03.SB2-0

GSW2KB0

1.0F08.SB2-0

CSB027 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Page 169: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

169 (270)

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No

OldCab/

OldFU/

OldPosition/

OldCab/ Old FU/

OldPosition/

Type Use NoteETPTIndex

NewCab

NewFU

NewPosition

NewCab New FU

NewPosition

BSCC_730 BSCCGTIC1

5.9F02.SB1-0

BSCCGSW2KB0

1.0F07.SB3-0

CSB027 1)ETPT1-0

5.9F07.SB2-0

1.0F08.SB2-0

BSCC_731 BSCCGTIC1

5.9F02.SB2-0

BSCCGSW2KB0

1.0F07.SB4-0

CSB027 1)ETPT1-0

5.9F07.SB3-0

1.0F08.SB1-0

BSCC_710 BSCC

GTIC0

5.6F01.SB1-0

BSCCGSW2KB0

1.0F01.SB2-0

CSB031 2)ETPT0-0

GTIC1

5.9F02.SB2-0

1.0F02.SB2-0

BSCC_711 BSCC

GTIC0

5.6F01.SB2-0

BSCCGSW2KB0

1.0F01.SB4-0

CSB030 2)ETPT0-0

GTIC1

5.9F02.SB3-0

1.0F02.SB4-0

BSCC_714 BSCCGTIC0

5.6F02.SB1-0

BSCCGSW2KB0

1.0F02.SB2-0

CSB031 2)ETPT0-1

5.6F02.SB2-0

1.0F02.SB2-1

BSCC_715 BSCCGTIC0

5.6F02.SB2-0

BSCCGSW2KB0

1.0F02.SB4-0

CSB030 2)ETPT0-1

5.6F02.SB3-0

1.0F02.SB4-1

BSCC_726 BSCC

GTIC1

5.9F01.SB1-0

BSCCGSW2KB0

1.0F06.SB2-0

CSB027 1)ETPT1-1

GTIC0

5.6F07.SB2-0

1.0F08.SB2-1

BSCC_727 BSCC

GTIC1

5.9F01.SB2-0

BSCCGSW2KB0

1.0F07.SB2-0

CSB027 1)ETPT1-1

GTIC0

5.6F07.SB3-0

1.0F08.SB1-1

Notes:

Page 170: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

170 (270)

1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

Equipping Cable from Cable to

No Old Old FU OldPosition

New FU NewPosition

OLd OldFU

OldPosition

Type Use Note

Cab Cab

BSCC_4372 BSCC GSW2KB0

1.0F02.SB4-0

GSW2KB0

1.0F07.SB4-1

BSCD ETC3

2.3F07.SB3-0

CSB024 Hotlink

BSCC_4360 BSCC GSW2KB0

1.0F02.SB2-0

GSW2KB0

1.0F07.SB3-1

BSCD ETC3

2.3F07.SB2-0

CSB027 Hotlink 3)

BSCC_4356 BSCC GSW2KB0

1.0F07.SB2-0

GSW2KB0

1.0F05.SB2-1

BSCD ETC5

2.9F07.SB2-0

CSB029 Hotlink 1)

BSCC_4368 BSCC GSW2KB0

1.0F06.SB2-0

GSW2KB0

1.0F05.SB4-1

BSCD ETC5

2.9F 07SB3-0

CSB029 Hotlink 1)

BSCC_4358 BSCC GSW2KB0

1.0F08.SB2-0

GSW2KB0

1.0F01.SB2-1

BSCD ETC5

2.9F02.SB2-0

CSB027 Hotlink 2)

BSCC_4370 BSCC GSW2KB0

1.0F08.SB1-0

GSW2KB0

1.0F01.SB4-1

BSCD ETC5

2.9F02.SB3-0

CSB029 Hotlink 2)

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-0 to required tracks, Hotlinks from GSW,0 to required tracks

Equipping CABLE FROM CABLE TO

No FU PositionCabinet FU

Position

Cabinet Type Use Note

ETPTIndex

BSCC_4300

LANU 0

1.8B05.1C

BSCC ETC 2 2.0B01.4G

BSCD CHES020

ETPLAN

ETPT2-1

BSCC_4302

LANU 0

1.8B05.1G

BSCC ETC 2 2.0B06.4G

BSCD CHES021

ETPLAN

ETPT3-0

BSCC_4303

LANU 0

1.8B05.1J

BSCC ETC 3 2.3B01.4G

BSCD CHES023

ETPLAN

ETPT2-0

BSCC_4305

LANU 0

1.8B05.1N

BSCC ETC 3 2.3B06.4G

BSCD CHES024

ETPLAN

ETPT3-1

BSCC_4306

LANU 0

1.8B05.1P

BSCC ETC 4 2.6B01.4G

BSCD CHES026

ETPLAN

ETPT4-0

Page 171: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

171 (270)

BSCC_4307

LANU 0

1.8B05.1R

BSCC ETC 4 2.6B06.4G

BSCD CHES027

ETPLAN

ETPT5-0

BSCC_4308

LANU 0

1.8B05.2C

BSCC ETC 5 2.9B01.4G

BSCD CHES028

ETPLAN

ETPT4-1

BSCC_4309

LANU 0

1.8B05.2E

BSCC ETC 5 2.9B06.4G

BSCD CHES029

ETPLAN

ETPT5-1

BSCD_4350

ETC4

2.6F07.SB2-0

BSCD GSW2KB 0

1.0F05.SB2-0

BSCC CSB027 HotlinkETPT5-0

BSCD_4352

ETC4

2.6F02.SB2-0 BSCD

GSW2KB 0

1.0F01.SB2-0 BSCC CSB027 Hotlink 1)

ETPT4-0

BSCD_4362

ETC4

2.6F07.SB3-0 BSCD

GSW2KB 0

1.0F05.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPT5-0

BSCD_4364

ETC4

2.6F02.SB3-0 BSCD

GSW2KB 0

1.0F01.SB4-0 BSCC CSB027 Hotlink 1), 2)

ETPT4-0

BSCD_4354

ETC2

2.0F07.SB2-0 BSCD

GSW2KB 0

1.0F07.SB3-0 BSCC CSB022 Hotlink 1)

ETPT3-0

BSCD_4366

ETC2

2.0F07.SB3-0 BSCD

GSW2KB 0

1.0F07.SB4-0 BSCC CSB021 Hotlink 1), 2)

ETPT3-0

BSCD_4620

ETC3

2.3F02.SB2-0 BSCD

GSW2KB 0

1.0F07.SB2-0 BSCC CSB026 Hotlink

3)Default

ETPT2-0

BSCD_4624

ETC3

2.3F02.SB3-0 BSCD

GSW2KB 0

1.0F06.SB2-0 BSCC CSB026 Hotlink 3)

ETPT2-0

BSCD_4622

ETC2

2.0F02.SB2-0 BSCD

GSW2KB 0

1.0F07.SB2-1 BSCC CSB026 Hotlink 3)

ETPT2-1

BSCD_4626

ETC2

2.0F02.SB3-0 BSCD

GSW2KB 0

1.0F06.SB2-1 BSCC CSB026 Hotlink 3)

ETPT2-1

BSCC_4400

LANU 0

1.8B05.2G BSCC

GTIC 0 5.6B06.4G BSCC

CHES023

ETPLAN

ETPE1-1

BSCC_4402

LANU 0

1.8B05.2L BSCC

GTIC 0 5.6B01.4G BSCC

CHES024

ETPLAN

ETPT0-1

BSCC_4403

LANU 0

1.8B05.2N

GTIC 1 5.9B06.4G

CHES021

ETPLAN

ETPT1-0

BSCC_4405

LANU 0

1.8B05.2R

GTIC 1 5.9B01.4G

CHES022

ETPLAN

ETPT0-0

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this slot(s).2) These cables are not used, if no PCU2-D is equipped3) These Hotlink cables are added in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot01/02 is taken in use.

Check SW256B dip switching. See appendix 1

12.2.1.3.2 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:MCMU,0:SE;ZUSC:MCMU,0:TE;ZUSC:MCMU,0:SP;

Page 172: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

172 (270)

ZUSC:MCMU,0:WO;

ZUSC:EMB,0:SE;ZUSC:EMB,0:TE;ZUSC:EMB,0:SP;

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;12.2.1.3.3 Change MCMU-1, SWU-1, SWU-3, and SWU-5 and SWU-7 SE-NH state

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SE;ZUSC:MCMU,1:SE;

ZUSC:EMB,1:TE;ZUSC:EMB,1:SE;ZUSC:EMB,1:SE;

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;ZUSC:SWU,3:SE;

ZUSC:SWU,5:TE;ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

12.2.1.3.3.1 For initial BSC 3i 1000/2000

12.2.1.3.3.1.1 For BSC 3i 1000

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Page 173: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

173 (270)

BSCC_716 BSCC GTIC 0 5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2)

ETPT 0-0

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717 BSCC GTIC 0 5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

ETPT 0-0

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1)

ETPT 1-0

GTIC 0 5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729 BSCC GTIC 1 5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1)

ETPT 1-0

GTIC 0 5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732 BSCC GTIC 1 5.9F02.SB1-1

BSCC GSW2KB1

1.3F07.SB3-0

CSB025 1)

ETPT 1-1

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733 BSCC GTIC 1 5.9F02.SB2-1

BSCC GSW2KB1

1.3F07.SB4-0

CSB025 1)

ETPT 1-1

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712 BSCC GTIC 0 5.6F01.SB1-1

BSCC GSW2KB1

1.3F01.SB2-0

CSB029 2)

ETPT 0-1

GTIC 1 5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713 BSCC GTIC 0 5.6F01.SB2-1

BSCC GSW2KB1

1.3F01.SB4-0

CSB028 2)

ETPT 0-1

GTIC 1 5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Add needed 2N,ETPLAN cables from LANU-1 to required tracks

Equipping CABLE FROM CABLE TO ETPT INDEX

Page 174: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

174 (270)

No FU Position FU Position Type Use Note

BSCC_4406 LANU 1 5.2B05.2E

GTIC 0 5.6B06.4J

CHES008 ETPLANETPT 1-0

BSCC_4408 LANU 1 5.2B05.2J

GTIC 0 5.6B01.4J

CHES007 ETPLANETPT 0-0

BSCC_4409 LANU 1 5.2B05.2L

GTIC 1 5.9B06.4J

CHES010 ETPLANETPT 1-1

BSCC_4411 LANU 1 5.2B05.2P

GTIC 1 5.9B01.4J

CHES009 ETPLANETPT 0-1

BSCC_1242 GTIC 15.9B02.4A GTIC 0

5.6B02.4A CHFX006 2N

1) ETPT 0-1/ETPT 0-0

BSCC_1252 GTIC 15.9B07.4A GTIC 0

5.6B07.4A CHFX006 2N

1) ETPT 1-1/ETPT 1-0

Notes:1) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready

for connecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s).

Add needed 2N Redundancy cables for mate STMU

Equipping Cable from Cable to

No Cabinet

FU Position

Cabinet

FU Position

Type Use

Note STMUINDEX

BSCC_1254 BSCC

GTIC 1

5.9B08.4A

- GTIC 0

5.6B08.4A

CHFX006 2N 1) 2)

STMU14/STMU-15

BSCC_1255 BSCC

GTIC 1

5.9B08.4G

- GTIC 0

5.6B08.4G

CHES006 2N 1) 2)

STMU14/STMU-15

Notes:1) These cables are not included in parts list.2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi

BSC upgrades (either C112220 or C112416). Only in case of ETS2 used as mate of ETP(T), slot by sloti.e. ETS2, redundancy pair by redundancy pair, the GTIC 1 ends of these cables (redundancy pairspecific 1 pcs CHFX and 1 pcs CHES) are to be connected if transmission redundancy is upgraded toHW redundancy.

3) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be readyfor connecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s).

12.2.1.3.3.1.2 BSC 3i 2000

Move and reconnect or add following cables if requiredEquipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

Page 175: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

175 (270)

BSCC_716

BSCC

GTIC0

5.6F02.SB1-1

BSCC

GSW2KB 1

1.3F03.SB2-0

CSB029

Hotlink

2)

ETPT 0-1

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717

BSCC

GTIC0

5.6F02.SB2-1

BSCC

GSW2KB 1

1.3F02.SB4-0

CSB028

Hotlink

2)

ETPT 0-1

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728

BSCC

GTIC1

5.9F01.SB1-1

BSCC

GSW2KB 1

1.3F06.SB2-0

CSB025

Hotlink

1)

ETPT 1-1

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729

BSCC

GTIC1

5.9F01.SB2-1

BSCC

GSW2KB 1

1.3F07.SB2-0

CSB025

Hotlink

1)

ETPT 1-1

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732

BSCC

GTIC1

5.9F02.SB1-1

BSCC

GSW2KB 1

1.3F07.SB3-0

CSB025

1)

ETPT 1-0

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733

BSCC

GTIC1

5.9F02.SB2-1

BSCC

GSW2KB 1

1.3F07.SB4-0

CSB025

1)

ETPT 1-0

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712

BSCC

GTIC0

5.6F01.SB1-1

BSCC

GSW2KB 1

1.3F01.SB2-0

CSB029

2)

ETPT 0-0

GTIC1

5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713

BSCC

GTIC0

5.6F01.SB2-1

BSCC

GSW2KB 1

1.3F01.SB4-0

CSB028

2)

ETPT 0-0

GTIC1

5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Equipping Cable from Cable to

No Old Old FU Old New FU New OLD Old Old Type Use Note ETPT

Page 176: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

176 (270)

Cab Position Position Cab FU Position INDEX

BSCC_4373 BSCC GSW2KB1

1.3F02.SB4-0

GSW2KB1

1.3F07.SB4-1

BSCD ETC3

2.3F07.SB3-1

CSB022 Hotlink

ETPT 3BSCC_4361 BSCC GSW2KB

11.3F02.SB2-0

GSW2KB1

1.3F07.SB3-1

BSCD ETC3

2.3F07.SB2-1

CSB025 Hotlink 3)

ETPT 3BSCC_4357 BSCC GSW2KB

11.3F07.SB2-0

GSW2KB1

1.3F05.SB2-1

BSCD ETC5

2.9F07.SB2-1

CSB027 Hotlink 1)

ETPT 5BSCC_4369 BSCC GSW2KB

11.3F06.SB2-0

GSW2KB1

1.3F05.SB4-1

BSCD ETC5

2.9F07.SB3-1

CSB027 Hotlink 1)

ETPT 5BSCC_4359 BSCC GSW2KB

11.3F08.SB2-0

GSW2KB1

1.3F01.SB2-1

BSCD ETC5

2.9F02.SB2-1

CSB026 Hotlink 2)

ETPT 4BSCC_4371 BSCC GSW2KB

11.3F08.SB1-0

GSW2KB1

1.3F01.SB4-1

BSCD ETC5

2.9F02.SB3-1

CSB027 Hotlink 2)

ETPT 4

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-1 to required tracks, Hotlinks from GSW,1 to required tracks

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU1

5.2B05.2E

GTIC0

5.6B06.4J

CHES008 ETPLANETPT 1-1

BSCC_4408 LANU1

5.2B05.2J

GTIC0

5.6B01.4J

CHES007 ETPLANETPT 0-1

BSCC_4409 LANU1

5.2B05.2L

GTIC1

5.9B06.4J

CHES010 ETPLANETPT 1-0

BSCC_4411 LANU1

5.2B05.2P

GTIC1

5.9B01.4J

CHES009 ETPLANETPT 0-0

Equipping CABLE FROM CABLE TO

No FU Position Cabinet FUPosition

Cabinet Type Use NoteETPTINDEX

BSCC_4310 LANU1

5.2B05.1A

BSCC ETC 2 2.0B01.4J

BSCD CHES043 ETPLAN ETPT2-1

BSCC_4312 LANU1

5.2B05.1E

BSCC ETC 2 2.0B06.4J

BSCD CHES042 ETPLAN ETPT3-0

BSCC_4313 LANU1

5.2B05.1G

BSCC ETC 3 2.3B01.4J

BSCD CHES041 ETPLAN ETPT2-0

BSCC_4315 LANU1

5.2B05.1L

BSCC ETC 3 2.3B06.4J

BSCD CHES040 ETPLAN ETPT3-1

Page 177: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

177 (270)

BSCC_4316 LANU1

5.2B05.1N

BSCC ETC 4 2.6B01.4J

BSCD CHES040 ETPLAN ETPT4-0

BSCC_4317 LANU1

5.2B05.1P

BSCC ETC 4 2.6B06.4J

BSCD CHES039 ETPLAN ETPT5-0

BSCC_4318 LANU1

5.2B05.1R

BSCC ETC 5 2.9B01.4J

BSCD CHES039 ETPLAN ETPT4-1

BSCC_4319 LANU1

5.2B05.2C

BSCC ETC 5 2.9B06.4J

BSCD CHES038 ETPLAN ETPT5-1

BSCD_4351 ETC4

2.6F07.SB2-1

BSCD GSW2KB1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPT5-0

BSCD_4363 ETC4

2.6F07.SB3-1

BSCD GSW2KB1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1),ETPT5-0

BSCD_4365 ETC4

2.6F02.SB3-1

BSCD GSW2KB1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1),ETPT4-0

BSCD_4353 ETC4

2.6F02.SB2-1

BSCD GSW2KB1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPT4-0

BSCD_4355 ETC2

2.0F07.SB2-1

BSCD GSW2KB1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPT3-0

BSCD_4367 ETC2

2.0F07.SB3-1

BSCD GSW2KB1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1),ETPT3-0

BSCD_4625 ETC3

2.3F02.SB3-1

BSCD GSW2KB1

1.3F06.SB2-0

BSCC CSB023 Hotlink 2) 3)ETPT2-0

BSCD_4621 ETC3

2.3F02.SB2-1

BSCD GSW2KB1

1.3F07.SB2-0

BSCC CSB023 Hotlink 2)Default ETPT

2-0BSCD_4623 ETC

22.0F02.SB2-1

BSCD GSW2KB1

1.3F07.SB2-1

BSCC CSB023 Hotlink 2)ETPT2-1

BSCD_4627 ETC2

2.0F02.SB3-1

BSCD GSW2KB1

1.3F06.SB2-1

BSCC CSB023 Hotlink 2) 3)ETPT2-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this

slot(s))

2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in FlexiBSC upgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancypair by redundancy pair, the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcsCHFX) are to be connected if transmission redundancy is upgraded to HW redundancy.

3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02 istaken in use.

Add needed 2N Redundancy cables.

Equipping Cable from Cable to

ETPT/STMU INDEX

No Cabinet

FU Position

Cabinet

FU Position

Type Use

Note

Page 178: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

178 (270)

BSCC_1242

GTIC 1

5.9B02.4A

GTIC 0

5.6B02.4A

CHFX006 2N

2) ETPT 0-0/ETPT 0-1

BSCC_1252

GTIC 1

5.9B07.4A

GTIC 0

5.6B07.4A

CHFX006 2N

2) ETPT 1-0/ETPT 1-1

BSCD_4454 BSCD

ETC5

2.9B07.4A

- ETC4

2.6B07.4A

CHFX006 2N 1) 3)

ETPT 5-0/ETPT 5-1

BSCD_4455 BSCD

ETC5

2.9B02.4A

- ETC4

2.6B02.4A

CHFX006 2N 1) 3)

ETPT 4-0/ETPT 4-1

BSCD_4456 BSCD

ETC2

2.0B07.4A

- ETC3

2.3B07.4A

CHFX006 2N 1) 3)

ETPT 3-1/ETPT 3-0

BSCD_4457 BSCD

ETC2

2.0B02.4A

- ETC3

2.3B02.4A

CHFX006 2N 1) 3)

ETPT 2-1/ETPT 2-0

BSCC_1254 BSCC

GTIC 1

5.9B08.4A

- GTIC 0

5.6B08.4A

CHFX006 2N 4) 5)

STMU-14/STMU-15

BSCC_1255 BSCC

GTIC 1

5.9B08.4G

- GTIC 0

5.6B08.4G

CHES006 2N 4) 5)

STMU-14/STMU-15

BSCC_1244

GTIC 1

5.9B03.4A

GTIC 0

5.6B03.4A

CHFX006 2N

6) STMU4/STMU-5

BSCC_1245

GTIC 1

5.9B03.4G

GTIC 0

5.6B03.4G

CHES006 2N

6) STMU4/STMU-5

BSCC_1246

GTIC 1

5.9B04.4A

GTIC 0

5.6B04.4A

CHFX006 2N

6) STMU-6/STMU-7

BSCC_1247

GTIC 1

5.9B04.4G

GTIC 0

5.6B04.4G

CHES006 2N

6) STMU-6/STMU-7

Notes:1) These cables are not included in parts list2) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready forconnecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s) 3) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by redundancy pair,the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to be connected iftransmission redundancy is upgraded to HW redundancy.4) These cables are not included in parts list.5) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Only in case of ETS2 used as mate of ETP(T), slot by slot i.e. ETS2,redundancy pair by redundancy pair, the ends of these cables (redundancy pair specific 1 pcs CHFX and 1 pcsCHES) are to be connected if transmission redundancy is upgraded to HW redundancy.6) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready forconnecting , but shall only be connected, if an ETS2 PIU is taken in use in this slot(s).

12.2.1.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.2.1.3.3.2.1 For upgraded flexi BSC Single cabinet.

Remove following cables if needed.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC0

5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC0

5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

Page 179: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

179 (270)

BSCC_732 GTIC1

5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 2)

BSCC_733 GTIC1

5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 2)

Notes:1) These cables have to be removed only, if ETP PIU is installed in GTIC 0 slots 1(and 2). 2) These cables have to be removed only, if ETP PIU is installed in GTIC 1 slots 1(and 2).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No OldCab/

Old FU/ OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note ETPTINDEX

NewCab

New FU NewPosition

NewCab

New FU NewPosition

BSCC_716 BSCC GTIC 0 5.6F02.SB1-1

BSCC GSW2KB1

1.3F03.SB2-0

CSB029 Hotlink 2) ETPT 00

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717 BSCC GTIC 0 5.6F02.SB2-1

BSCC GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2) ETPT 00

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728 BSCC GTIC1 5.9F01.SB1-1

BSCC GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 1) ETPT 10

GTIC 0 5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729 BSCC GTIC 1 5.9F01.SB2-1

BSCC GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 1) ETPT 10

GTIC 0 5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732 BSCC GTIC 1 5.9F02.SB1-1

BSCC GSW2KB1

1.3F07.SB3-0

CSB025 1) ETPT 11

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733 BSCC GTIC 1 5.9F02.SB2-1

BSCC GSW2KB1

1.3F07.SB4-0

CSB025 1) ETPT 11

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712 BSCC GTIC 0 5.6F01.SB1-1

BSCC GSW2KB1

1.3F01.SB2-0

CSB029 2) ETPT 01

Page 180: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

180 (270)

GTIC 1 5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713 BSCC GTIC 0 5.6F01.SB2-1

BSCC GSW2KB1

1.3F01.SB4-0

CSB028 2) ETPT 01

GTIC 1 5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

01/02 is taken in use.

Add following ETPLAN cables,2N cables if required.

Equipping CABLE FROM CABLE TOETPTINDEXNo FU Position FU Position Type Use Note

BSCC_4406 LANU 1 1.10B05.2G

GTIC 0 5.6B06.4J

CHES022 ETPLAN ETPT 1-0

BSCC_4408 LANU 1 1.10B05.2L

GTIC 0 5.6B01.4J

CHES023 ETPLAN ETPT 0-0

BSCC_4409 LANU 1 1.10B05.2N

GTIC 1 5.9B06.4J

CHES020 ETPLAN ETPT 1-1

BSCC_4411 LANU 1 1.10B05.2R

GTIC 1 5.9B01.4J

CHES021 ETPLAN ETPT 0-1

BSCC_1242 GTIC 15.9B02.4A GTIC 0

5.6B02.4A CHFX006 2N

1) ETPT0-1/ETPT 0-0

BSCC_1252 GTIC 15.9B07.4A GTIC 0

5.6B07.4A CHFX006 2N

1) ETPT1-1/ ETPT1-0

Notes:1) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready

for connecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s)

Equipping Cable from Cable to

No Cabinet

FU Position

Cabinet

FU Position

Type Use

Note STMUINDEX

BSCC_1254 BSCC

GTIC 1

5.9B08.4A

- GTIC 0

5.6B08.4A

CHFX006 2N 1) 2)

STMU14/STMU-15

BSCC_1255 BSCC

GTIC 1

5.9B08.4G

- GTIC 0

5.6B08.4G

CHES006 2N 1) 2)

STMU14/STMU-15

Notes:1) These cables are not included in parts list.2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi

BSC upgrades(either C112220 or C112416). Only in case of ETS2 used as mate of ETP(T), slot by slot i.e.ETS2, redundancy pair by redundancy pair, the GTIC 1 ends of these cables (redundancy pair specific 1pcs CHFX and 1 pcs CHES) are to be connected if transmission redundancy is upgraded to HWredundancy.

Page 181: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

181 (270)

12.2.1.3.3.2.2 For upgraded flexi BSC Double cabinet.

Remove following cables if required.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note

BSCC_712 GTIC0

5.6F01.SB1-1

GSW2KB1

1.3F01.SB2-0

CSB029 Hotlink 1)

BSCC_713 GTIC0

5.6F01.SB2-1

GSW2KB1

1.3F01.SB4-0

CSB028 Hotlink 1)

BSCC_716 GTIC0

5.6F02.SB1-1

GSW2KB1

1.3F02.SB2-0

CSB029 Hotlink 2)

BSCC_717 GTIC0

5.6F02.SB2-1

GSW2KB1

1.3F02.SB4-0

CSB028 Hotlink 2)

BSCC_720 GTIC0

5.6F03.SB1-1

GSW2KB1

1.3F05.SB2-0

CSB027 Hotlink 3)

BSCC_721 GTIC0

5.6F03.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB026 Hotlink 3)

BSCC_728 GTIC1

5.9F01.SB1-1

GSW2KB1

1.3F06.SB2-0

CSB025 Hotlink 4)

BSCC_729 GTIC1

5.9F01.SB2-1

GSW2KB1

1.3F07.SB2-0

CSB025 Hotlink 4)

BSCC_732 GTIC1

5.9F02.SB1-1

GSW2KB1

1.3F07.SB3-0

CSB025 Hotlink 5)

BSCC_733 GTIC1

5.9F02.SB2-1

GSW2KB1

1.3F07.SB4-0

CSB025 Hotlink 5)

BSCC_736 GTIC1

5.9F03.SB1-1

GSW2KB1

1.3F08.SB1-0

CSB025 Hotlink 6)

BSCC_737 GTIC1

5.9F03.SB2-1

GSW2KB1

1.3F08.SB2-0

CSB025 Hotlink 6)

Notes:1) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 1(and 2)2) These cables have to be removed only, if ETP PIU is installed in ETC 3 slots 6(and 7)3) These cables have to be removed only, if ETP PIU is installed in ETC 4 slots 6(and 7)4) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 6(and 7)5) These cables have to be removed only, if ETP PIU is installed in ETC 2 slots 6(and 7)6) These cables have to be removed only, if ETP PIU is installed in ETC 5 slots 1(and 2)

Move and reconnect or add following cables if required

Equipping Cable from Cable to

Page 182: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

182 (270)

No OldCab/

OldFU/

OldPosition/

OldCab/

Old FU/ OldPosition/

Type Use Note ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

New FU NewPosition

BSCC_716

BSCC

GTIC0

5.6F02.SB1-1

BSCC

GSW2KB 1

1.3F03.SB2-0

CSB029

Hotlink

2) ETPT0-1

5.6F02.SB2-1

1.3F02.SB2-1

BSCC_717

BSCC

GTIC0

5.6F02.SB2-1

BSCC

GSW2KB 1

1.3F02.SB4-0

CSB028

Hotlink

2) ETPT0-1

5.6F02.SB3-1

1.3F02.SB4-1

BSCC_728

BSCC

GTIC1

5.9F01.SB1-1

BSCC

GSW2KB 1

1.3F06.SB2-0

CSB025

Hotlink

1) ETPT1-1

GTIC0

5.6F07.SB2-1

1.3F08.SB2-1

BSCC_729

BSCC

GTIC1

5.9F01.SB2-1

BSCC

GSW2KB 1

1.3F07.SB2-0

CSB025

Hotlink

1) ETPT1-1

GTIC0

5.6F07.SB3-1

1.3F08.SB1-1

BSCC_732

BSCC

GTIC1

5.9F02.SB1-1

BSCC

GSW2KB 1

1.3F07.SB3-0

CSB025

1) ETPT1-0

5.9F07.SB2-1

1.3F08.SB2-0

BSCC_733

BSCC

GTIC1

5.9F02.SB2-1

BSCC

GSW2KB 1

1.3F07.SB4-0

CSB025

1) ETPT1-0

5.9F07.SB3-1

1.3F08.SB1-0

BSCC_712

BSCC

GTIC0

5.6F01.SB1-1

BSCC

GSW2KB 1

1.3F01.SB2-0

CSB029

2) ETPT0-0

GTIC1

5.9F02.SB2-1

1.3F02.SB2-0

BSCC_713

BSCC

GTIC0

5.6F01.SB2-1

BSCC

GSW2KB 1

1.3F01.SB4-0

CSB028

2) ETPT0-0

GTIC1

5.9F02.SB3-1

1.3F02.SB4-0

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot

06/07 is taken in use.

Page 183: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

183 (270)

2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair GTIC 0 & 1 slot01/02 is taken in use.

Equipping Cable from Cable to

No Old Old FU OldPosition

New FU NewPosition

OLD OldFU

OldPosition

Type Use Note

ETPTINDEX

Cab Cab

BSCC_4373 BSCC GSW2KB1

1.3F02.SB4-0

GSW2KB1

1.3F07.SB4-1

BSCD ETC3

2.3F07.SB3-1

CSB022 Hotlink

ETPT 3BSCC_4361 BSCC GSW2KB

11.3F02.SB2-0

GSW2KB1

1.3F07.SB3-1

BSCD ETC3

2.3F07.SB2-1

CSB025 Hotlink 3)

ETPT 3BSCC_4357 BSCC GSW2KB

11.3F07.SB2-0

GSW2KB1

1.3F05.SB2-1

BSCD ETC5

2.9F07.SB2-1

CSB027 Hotlink 1)

ETPT 5BSCC_4369 BSCC GSW2KB

11.3F06.SB2-0

GSW2KB1

1.3F05.SB4-1

BSCD ETC5

2.9F07.SB3-1

CSB027 Hotlink 1)

ETPT 5BSCC_4359 BSCC GSW2KB

11.3F08.SB2-0

GSW2KB1

1.3F01.SB2-1

BSCD ETC5

2.9F02.SB2-1

CSB026 Hotlink 2)

ETPT 4BSCC_4371 BSCC GSW2KB

11.3F08.SB1-0

GSW2KB1

1.3F01.SB4-1

BSCD ETC5

2.9F02.SB3-1

CSB027 Hotlink 2)

ETPT 4

Notes:1) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use2) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 4 & 5 slot01/02 is taken in use.3) These Hotlinks are moved in a situation where ETP(T) or ETP(E) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

Added ETPLAN from LANU-1 to required tracks, Hotlinks from GSW,1 to required tracks

Equipping CABLE FROM CABLE TO ETPTINDEX

No FU Position FU Position Type Use Note

BSCC_4406 LANU1

5.2B05.2E

GTIC0

5.6B06.4J

CHES008 ETPLAN ETPT1-1

BSCC_4408 LANU1

5.2B05.2J

GTIC0

5.6B01.4J

CHES007 ETPLAN ETPT0-1

BSCC_4409 LANU1

5.2B05.2L

GTIC1

5.9B06.4J

CHES010 ETPLAN ETPT1-0

BSCC_4411 LANU1

5.2B05.2P

GTIC1

5.9B01.4J

CHES009 ETPLAN ETPT0-0

Equipping CABLE FROM CABLE TO

Page 184: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

184 (270)

No FU Position Cabinet

FUPosition

Cabinet

Type Use Note ETPTINDEX

BSCC_4310

LANU 1

1.10B05.1C

BSCC ETC 2 2.0B01.4J

BSCD CHES022

ETPLAN

ETPT2-1

BSCC_4312

LANU 1

1.10B05.1G

BSCC ETC 2 2.0B06.4J

BSCD CHES023

ETPLAN

ETPT3-0

BSCC_4313

LANU 1

1.10B05.1J

BSCC ETC 3 2.3B01.4J

BSCD CHES025

ETPLAN

ETPT2-0

BSCC_4315

LANU 1

1.10B05.1N

BSCC ETC 3 2.3B06.4J

BSCD CHES026

ETPLAN

ETPT3-1

BSCC_4316

LANU 1

1.10B05.1P

BSCC ETC 4 2.6B01.4J

BSCD CHES028

ETPLAN

ETPT4-0

BSCC_4317

LANU 1

1.10B05.1R

BSCC ETC 4 2.6B06.4J

BSCD CHES029

ETPLAN

ETPT5-0

BSCC_4318

LANU 1

1.10B05.2C

BSCC ETC 5 2.9B01.4J

BSCD CHES030

ETPLAN

ETPT4-1

BSCC_4319

LANU 1

1.10B05.2E

BSCC ETC 5 2.9B06.4J

BSCD CHES031

ETPLAN

ETPT5-1

BSCD_4351

ETC4

2.6F07.SB2-1

BSCD GSW2KB 1

1.3F05.SB2-0

BSCC CSB025 Hotlink 1)ETPT5-0

BSCD_4363

ETC4

2.6F07.SB3-1

BSCD GSW2KB 1

1.3F05.SB4-0

BSCC CSB025 Hotlink 1),ETPT5-0

BSCD_4365

ETC4

2.6F02.SB3-1

BSCD GSW2KB 1

1.3F01.SB4-0

BSCC CSB025 Hotlink 1),ETPT4-0

BSCD_4353

ETC4

2.6F02.SB2-1

BSCD GSW2KB 1

1.3F01.SB2-0

BSCC CSB025 Hotlink 1)ETPT4-0

BSCD_4355

ETC2

2.0F07.SB2-1

BSCD GSW2KB 1

1.3F07.SB3-0

BSCC CSB020 Hotlink 1)ETPT3-0

BSCD_4367

ETC2

2.0F07.SB3-1

BSCD GSW2KB 1

1.3F07.SB4-0

BSCC CSB019 Hotlink 1),ETPT3-0

BSCD_4625

ETC3

2.3F02.SB3-1

BSCD GSW2KB 1

1.3F06.SB2-0

BSCC

CSB023 Hotlink 2) 3)ETPT2-0

BSCD_4621

ETC3

2.3F02.SB2-1

BSCD GSW2KB 1

1.3F07.SB2-0

BSCC

CSB023 Hotlink

2)Default

ETPT2-0

BSCD_4623

ETC2

2.0F02.SB2-1

BSCD GSW2KB 1

1.3F07.SB2-1

BSCC

CSB023 Hotlink 2)ETPT2-1

BSCD_4627

ETC2

2.0F02.SB3-1

BSCD GSW2KB 1

1.3F06.SB2-1

BSCC

CSB023 Hotlink 2) 3)ETPT2-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use in this

slot(s))

2) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in FlexiBSC upgrades(either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by

Page 185: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

185 (270)

redundancy pair, the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) areto be connected if transmission redundancy is upgraded to HW redundancy.

3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02is taken in use.

Add needed 2N Redundancy cables.Equipping Cable from Cable to

ETPT/STMU INDEX

No Cabinet

FU Position

Cabinet

FU Position

Type Use

Note

BSCC_1242 BSCC

GTIC 1

5.9B02.4A BSCC

GTIC 0

5.6B02.4A CHFX006 2N

2) ETPT 0-0/ETPT 0-1

BSCC_1252 BSCC

GTIC 1

5.9B07.4A BSCC

GTIC 0

5.6B07.4A CHFX006 2N

2) ETPT 1-0/ETPT 1-1

BSCD_4454 BSCD

ETC5

2.9B07.4A BSCD

ETC4

2.6B07.4A CHFX006 2N 1) 3)

ETPT 5-0/ETPT 5-1

BSCD_4455 BSCD

ETC5

2.9B02.4A BSCD

ETC4

2.6B02.4A CHFX006 2N 1) 3)

ETPT 4-0/ETPT 4-1

BSCD_4456 BSCD

ETC2

2.0B07.4A BSCD

ETC3

2.3B07.4A CHFX006 2N 1) 3)

ETPT 3-1/ETPT 3-0

BSCD_4457 BSCD

ETC2

2.0B02.4A BSCD

ETC3

2.3B02.4A CHFX006 2N 1) 3)

ETPT 2-1/ETPT 2-0

BSCC_1254 BSCC

GTIC 1

5.9B08.4A BSCC

GTIC 0

5.6B08.4A CHFX006 2N 4) 5)

STMU-14/STMU-15

BSCC_1255 BSCC

GTIC 1

5.9B08.4G BSCC

GTIC 0

5.6B08.4G

CHES006 2N 4) 5)

STMU-14/STMU-15

BSCC_1244 BSCC

GTIC 1

5.9B03.4A BSCC

GTIC 0

5.6B03.4A CHFX006 2N

6) STMU4/STMU-5

BSCC_1245 BSCC

GTIC 1

5.9B03.4G BSCC

GTIC 0

5.6B03.4G

CHES006 2N

6) STMU4/STMU-5

BSCC_1246 BSCC

GTIC 1

5.9B04.4A BSCC

GTIC 0

5.6B04.4A CHFX006 2N

6) STMU-6/STMU-7

BSCC_1247 BSCC

GTIC 1

5.9B04.4G BSCC

GTIC 0

5.6B04.4G

CHES006 2N

6) STMU-6/STMU-7

Notes:1) These cables are not included in parts list 2) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready forconnecting , but shall only be connected, if an ETP PIU is taken in use in this slot(s) 3) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Slot by slot i.e. ETP(T) or ETP(E), redundancy pair by redundancy pair,the ETC 3 and ETC 5 ends of these cables (redundancy pair specific 1 pcs CHFX) are to be connected iftransmission redundancy is upgraded to HW redundancy. 4) These cables are not included in parts list.5) These cables have been delivered with Cabinet Upgrade Set for introduction ETP / ETP-A Units in Flexi BSCupgrades (either C112220 or C112416). Only in case of ETS2 used as mate of ETP(T), slot by slot i.e. ETS2,redundancy pair by redundancy pair, the ends of these cables (redundancy pair specific 1 pcs CHFX and 1 pcsCHES) are to be connected if transmission redundancy is upgraded to HW redundancy.6) These cables are included in parts list. Cables are routed and tied to cable supporting shelf to be ready forconnecting , but shall only be connected, if an ETS2 PIU is taken in use in this slot(s).

Check SW256B dip switching. See appendix 1

12.2.1.3.4 Change MCMU-1 to SP-EX, SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:MCMU,1:SE;

Page 186: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

186 (270)

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SP;

ZUSC:SWU,1:SE;ZUSC:SWU,1:TE;ZUSC:SWU,1:WO;

ZUSC:SWU,3:SE;ZUSC:SWU,3:TE;ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE;ZUSC:SWU,5:TE;ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE;ZUSC:SWU,7:TE;ZUSC:SWU,7:WO;

12.2.1.3.5 Cablings from ETPT card to STMU card

12.2.1.3.5.1 For ini BSC 3i 1000/2000

12.2.1.3.5.1.1 BSC 3i 1000

Move and reconnect or add following cables if required.Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

OldFU/

OldPosition/

Type Use Note

ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

NewFU

NewPosition

BSCC_4703 BSCC

GTIC0

5.6F08.SB2-1

BSCC

GTIC0

5.6F01.SB1-1

CSB008 1) 2) ETPT 0-1GTIC1

5.9F08.SB2-1

GTIC1

5.9F01.SB1-1

BSCC_4701 BSCC

GTIC0

5.6F08.SB1-1

BSCC

GTIC0

5.6F06.SB1-1

CSB006 1) 2) ETPT 1-1GTIC1

5.9F08.SB1-1

GTIC1

5.9F06.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 is

taken in use.2) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 is

taken in use.

Add cables if required.

Equipping Cable from Cable to

ETPTINDEX

No Cabinet FU Position Cabinet FU Position Type Use Note

Page 187: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

187 (270)

BSCC_4607 BSCC GTIC1

5.9F08.SB2-0 - GTIC

0

5.6F01.SB1-1

CSB009 Hotlink 3) ETPT0-0

BSCC_4606 BSCC GTIC0

5.6F08.SB2-1 - GTIC

1

5.9F01.SB1-0

CSB007 Hotlink 3) ETPT0-1

BSCC_4604 BSCC GTIC1

5.9F08.SB1-0 - GTIC

0

5.6F06.SB1-1

CSB009 Hotlink 2)default

ETPT1-0

BSCC_4605 BSCC GTIC0

5.6F08.SB1-1 - GTIC

1

5.9F06.SB1-0

CSB007 Hotlink 2)Default

ETPT1-1

BSCC_4700 GTIC0

5.6F08.SB1-0

GTIC0

5.6F06.SB1-0

CSB006 Hotlink 1) ETPT1-0

BSCC_4702 GTIC0

5.6F08.SB2-0

GTIC0

5.6F01.SB1-0

CSB008 Hotlink 1) ETPT0-0

Notes:1) Cables BSCC_4700 – BSCC_4703 are installed and tied to the front side of the cabinet to be ready forconnecting to plug in units. These cables are used if “ETS22) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

12.2.1.3.5.1.2 For BSC 3i 2000

Add following cables.

Equipping Cable from Cable to

ETPTINDEX

No Cabinet FU Position Cabinet FU Position Type Use Note

BSCC_4608 BSCC GTIC1

5.9F08.SB2-1

- GTIC0

5.6F01.SB1-1

CSB009 Hotlink 1)ETPT0-1

BSCC_4609 BSCC GTIC1

5.9F08.SB2-0

- GTIC1

5.9F01.SB1-1

CSB007 Hotlink 1)ETPT0-0

BSCC_4611 BSCC GTIC0

5.6F08.SB2-0

- GTIC1

5.9F01.SB1-0

CSB009 Hotlink 1)ETPT0-0

BSCC_4604 BSCC GTIC1

5.9F08.SB1-1

- GTIC0

5.6F06.SB1-1

CSB009 Hotlink 2)Default ETPT

1-1BSCC_4605 BSCC GTIC

15.9F08.SB1-0

- GTIC1

5.9F06.SB1-1

CSB007 Hotlink 2)Default ETPT

1-0BSCC_4607 BSCC GTIC

05.6F08.SB1-0

- GTIC1

5.9F06.SB1-0

CSB009 Hotlink 2)ETPT1-0

BSCC_4600 BSCC GTIC1

5.9F03.SB2-1

BSCD ETC2

2.0F01.SB1-1

CSB046 Hotlink 3)Default ETPT

2-1

Page 188: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

188 (270)

BSCC_4601 BSCC GTIC1

5.9F03.SB2-0

BSCD ETC3

2.3F01.SB1-1

CSB046 Hotlink 3)ETPT2-0

BSCC_4602 BSCC GTIC0

5.6F03.SB2-1

BSCD ETC2

2.0F01.SB1-0

CSB046 Hotlink 3)ETPT2-1

BSCC_4603 BSCC GTIC0

5.6F03.SB2-0

BSCD ETC3

2.3F01.SB1-0

CSB046 Hotlink 3)ETPT2-0

BSCD_4509 BSCD ETC3

2.3F06.SB1-1

BSCC GTIC1

5.9F03.SB1-1

CSB050 Hotlink 4)ETPT3-1

BSCD_4502 BSCD ETC4

2.6F01.SB1-0

BSCC GTIC0

5.6F04.SB2-0

CSB052 Hotlink 4)ETPT4-0

BSCD_4505 BSCD ETC5

2.9F06.SB1-1

BSCC GTIC1

5.9F04.SB1-1

CSB046 Hotlink 4)ETPT5-1

Notes:1) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.2) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02 is takenin use.4) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETPT in thisslot(s).

Move and reconnect or add following cables if required.

Equipping

Cable from Cable to

No Old OldFU

OldPosition

NewFU

NewPosition

OLd OldFU

OldPosition

Type Use NoteETPTINDEXCab Cab

BSCD_4510

BSCC

GTIC 1

5.9F03.SB2-0

GTIC 0

5.6F03.SB1-0

BSCD

ETC 2

2.0F06.SB1-0

CSB007

Hotlink

3)ETPT3-0

BSCD_4511

BSCC

GTIC 1

5.9F03.SB2-1

GTIC 1

5.9F03.SB1-0

BSCD

ETC 2

2.0F06.SB1-1

CSB007

Hotlink

3)ETPT3-0

BSCD_4508

BSCC

GTIC 1

5.9F03.SB1-0

GTIC 0

5.6F03.SB1-1

BSCD

ETC 3

2.3F06.SB1-0

CSB050

Hotlink

3)ETPT3-1

BSCD_4500

BSCC

GTIC 0

5.6F04.SB1-0

GTIC 1

5.9F04.SB2-1

BSCD

ETC 5

2.9F01.SB1-0

CSB050

Hotlink

1)ETPT4-1

BSCD_4501

BSCC

GTIC 0

5.6F04.SB1-1

GTIC 0

5.6F04.SB2-1

BSCD

ETC 5

2.9F01.SB1-1

CSB050

Hotlink

1)ETPT4-1

BSCD_4503

BSCC

GTIC 0

5.6F04.SB2-1

GTIC 1

5.9F04.SB2-0

BSCD

ETC 4

2.6F01.SB1-1

CSB052

Hotlink

1)ETPT4-0

BSCD_4504

BSCC

GTIC 1

5.9F04.SB1-0

GTIC 0

5.6F04.SB1-1

BSCD

ETC 5

2.9F06.SB1-0

CSB046

Hotlink

2)ETPT5-1

Page 189: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

189 (270)

BSCD_4506

BSCC

GTIC 1

5.9F04.SB2-0

GTIC 0

5.6F04.SB1-0

BSCD

ETC 4

2.6F06.SB1-0

CSB048

Hotlink

2)ETPT5-0

BSCD_4507

BSCC

GTIC 1

5.9F04.SB2-1

GTIC 1

5.9F04.SB1-0

BSCD

ETC 4

2.6F06.SB1-1

CSB048

Hotlink

2)ETPT5-0

BSCC_4700

BSCC

GTIC 0

5.6F08.SB1-0

GTIC 0

5.6F08.SB1-1

BSCC

GTIC 0

5.6F06.SB1-0

CSB006

Hotlink

4)ETPT1-1

BSCC_4702

BSCC

GTIC 0

5.6F08.SB2-0

GTIC 0

5.6F08.SB2-1

BSCC

GTIC 0

5.6F01.SB1-0

CSB008

Hotlink

5)ETPT0-1

Notes:

1) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.

2) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.

3) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

4) These Hotlink cables are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07is taken in use.

5) These Hotlink cables are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02is taken in use.

12.2.1.3.5.2 For upgraded flexi BSC Single cabinet/Double cabinet

12.2.1.3.5.2.1 For upgraded flexi BSC Single cabinet.

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No OldCab/

OldFU/

OldPosition/

OldCab/

OldFU/

OldPosition/

Type Use Note ETPTINDEX

NewCab

NewFU

NewPosition

NewCab

NewFU

NewPosition

BSCC_4703 BSCC

GTIC0

5.6F08.SB2-1

BSCC

GTIC0

5.6F01.SB1-1

CSB008 1) 2)ETPT0-1

GTIC1

5.9F08.SB2-1

GTIC1

5.9F01.SB1-1

BSCC_4701 BSCC

GTIC0

5.6F08.SB1-1

BSCC

GTIC0

5.6F06.SB1-1

CSB006 1) 2)ETPT1-1

GTIC1

5.9F08.SB1-1

GTIC1

5.9F06.SB1-1

Notes:1) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 is takenin use.

Page 190: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

190 (270)

2) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 is takenin use.

Add cables if required.

Equipping Cable from Cable toETPTINDEXNo Cabinet FU Position Cabinet FU Position Type Use Note

BSCC_4607 BSCCGTIC1

5.9F08.SB2-0 -

GTIC0

5.6F01.SB1-1 CSB009 Hotlink 3)

ETPT 0-0

BSCC_4606 BSCCGTIC0

5.6F08.SB2-1 -

GTIC1

5.9F01.SB1-0 CSB007 Hotlink 3)

ETPT 0-1

BSCC_4604 BSCCGTIC1

5.9F08.SB1-0 -

GTIC0

5.6F06.SB1-1 CSB009 Hotlink

2)Default

ETPT 1-0

BSCC_4605 BSCCGTIC0

5.6F08.SB1-1 -

GTIC1

5.9F06.SB1-0 CSB007 Hotlink

2)Default

ETPT 1-1

BSCC_4700GTIC0

5.6F08.SB1-0

GTIC0

5.6F06.SB1-0 CSB006 Hotlink 1)

ETPT 1-0

BSCC_4702GTIC0

5.6F08.SB2-0

GTIC0

5.6F01.SB1-0 CSB008 Hotlink 1)

ETPT 0-0

Notes:1) Cables BSCC_4700 – BSCC_4703 are installed and tied to the front side of the cabinet to be ready forconnecting to plug in units. These cables are used if “ETS22) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.

12.2.1.3.5.2.2 For upgraded flexi BSC Double cabinet.

Add following cables.

Equipping Cable from Cable to

ETPTINDEX

No Cabinet FU Position Cabinet FU Position Type Use Note

BSCC_4608 BSCC GTIC1

5.9F08.SB2-1

- GTIC0

5.6F01.SB1-1

CSB009 Hotlink 1)ETPT0-1

BSCC_4609 BSCC GTIC1

5.9F08.SB2-0

- GTIC1

5.9F01.SB1-1

CSB007 Hotlink 1)ETPT0-0

BSCC_4611 BSCC GTIC0

5.6F08.SB2-0

- GTIC1

5.9F01.SB1-0

CSB009 Hotlink 1)ETPT0-0

Page 191: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

191 (270)

BSCC_4604 BSCC GTIC1

5.9F08.SB1-1

- GTIC0

5.6F06.SB1-1

CSB009 Hotlink 2)Default ETPT

1-1BSCC_4605 BSCC GTIC

15.9F08.SB1-0

- GTIC1

5.9F06.SB1-1

CSB007 Hotlink 2)Default ETPT

1-0BSCC_4607 BSCC GTIC

05.6F08.SB1-0

- GTIC1

5.9F06.SB1-0

CSB009 Hotlink 2)ETPT1-0

BSCC_4600 BSCC GTIC1

5.9F03.SB2-1

BSCD ETC2

2.0F01.SB1-1

CSB046 Hotlink 3)Default ETPT

2-1BSCC_4601 BSCC GTIC

15.9F03.SB2-0

BSCD ETC3

2.3F01.SB1-1

CSB046 Hotlink 3)ETPT2-0

BSCC_4602 BSCC GTIC0

5.6F03.SB2-1

BSCD ETC2

2.0F01.SB1-0

CSB046 Hotlink 3)ETPT2-1

BSCC_4603 BSCC GTIC0

5.6F03.SB2-0

BSCD ETC3

2.3F01.SB1-0

CSB046 Hotlink 3)ETPT2-0

BSCD_4509 BSCD ETC3

2.3F06.SB1-1

BSCC GTIC1

5.9F03.SB1-1

CSB050 Hotlink 4)ETPT3-1

BSCD_4502 BSCD ETC4

2.6F01.SB1-0

BSCC GTIC0

5.6F04.SB2-0

CSB052 Hotlink 4)ETPT4-0

BSCD_4505 BSCD ETC5

2.9F06.SB1-1

BSCC GTIC1

5.9F04.SB1-1

CSB046 Hotlink 4)ETPT5-1

Notes:1) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02 istaken in use.2) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07 istaken in use.3) These Hotlink cables are added in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 01/02 is takenin use.4) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETPT in thisslot(s).

Move and reconnect or add following cables if required.

Equipping Cable from Cable to

No Old OldFU

OldPosition

NewFU

NewPosition

OLd OldFU

OldPosition

Type Use Note

ETPTINDEXCab Cab

BSCD_4510

BSCC

GTIC 1

5.9F03.SB2-0

GTIC 0

5.6F03.SB1-0

BSCD

ETC2

2.0F06.SB1-0

CSB007

Hotlink

3)ETPT3-0

BSCD_4511

BSCC

GTIC 1

5.9F03.SB2-1

GTIC 1

5.9F03.SB1-0

BSCD

ETC2

2.0F06.SB1-1

CSB007

Hotlink

3)ETPT3-0

BSCD_4508

BSCC

GTIC 1

5.9F03.SB1-0

GTIC 0

5.6F03.SB1-1

BSCD

ETC3

2.3F06.SB1-0

CSB050

Hotlink

3)ETPT3-1

BSCD_4500

BSCC

GTIC 0

5.6F04.SB1-0

GTIC 1

5.9F04.SB2-1

BSCD

ETC5

2.9F01.SB1

CSB050

Hotlink

1) ETPT4-1

Page 192: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

192 (270)

-0

BSCD_4501

BSCC

GTIC 0

5.6F04.SB1-1

GTIC 0

5.6F04.SB2-1

BSCD

ETC5

2.9F01.SB1-1

CSB050

Hotlink

1)ETPT4-1

BSCD_4503

BSCC

GTIC 0

5.6F04.SB2-1

GTIC 1

5.9F04.SB2-0

BSCD

ETC4

2.6F01.SB1-1

CSB052

Hotlink

1)ETPT4-0

BSCD_4504

BSCC

GTIC 1

5.9F04.SB1-0

GTIC 0

5.6F04.SB1-1

BSCD

ETC5

2.9F06.SB1-0

CSB046

Hotlink

2)ETPT5-1

BSCD_4506

BSCC

GTIC 1

5.9F04.SB2-0

GTIC 0

5.6F04.SB1-0

BSCD

ETC4

2.6F06.SB1-0

CSB048

Hotlink

2)ETPT5-0

BSCD_4507

BSCC

GTIC 1

5.9F04.SB2-1

GTIC 1

5.9F04.SB1-0

BSCD

ETC4

2.6F06.SB1-1

CSB048

Hotlink

2)ETPT5-0

BSCC_4700

BSCC

GTIC 0

5.6F08.SB1-0

GTIC 0

5.6F08.SB1-1

BSCC

GTIC 0

5.6F06.SB1-0

CSB006

Hotlink

4)ETPT1-1

BSCC_4702

BSCC

GTIC 0

5.6F08.SB2-0

GTIC 0

5.6F08.SB2-1

BSCC

GTIC 0

5.6F01.SB1-0

CSB008

Hotlink

5)ETPT0-1

Notes:

1) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 4 & 5 slot 01/02 istaken in use.

2) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 4 & 5 slot 06/07 istaken in use.

3) These Hotlinks are moved in a situation where ETP(T) HW redundancy pair ETC 2 & 3 slot 06/07 istaken in use.

4) These Hotlink cables are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 06/07is taken in use.

5) These Hotlink cables are moved in a situation where ETP(T) HW redundancy pair GTIC 0 & 1 slot 01/02is taken in us

12.2.2 Create HW configuration

Create cartridges if not exist ( ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

GTIC-0 cartridge: ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

GTIC-1 catridge: ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 catridge: ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 catridge: ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 catridge: ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 catridge: ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

Page 193: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

193 (270)

Create ETPT functional unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet ZWTU:ETPT,0,0:1A5-6; ZWTU:ETPT,0,1:1A5-9;

ZWTU:ETPT,1,0:1A5-6; ZWTU:ETPT,1,1:1A5-9;

For BSC 3i 2000/Upgraded Flexi Double cabinetZWTU:ETPT,0,0:1A5-9;

ZWTU:ETPT,0,1:1A5-6; ZWTU:ETPT,1,0:1A5-9; ZWTU:ETPT,1,1:1A5-6;

ZWTU:ETPT,2,0:1B2-3; ZWTU:ETPT,2,1:1B2-0;

ZWTU:ETPT,3,0:1B2-0; ZWTU:ETPT,3,1:1B2-3;

ZWTU:ETPT,4,0:1B2-6; ZWTU:ETPT,4,1:1B2-9;

ZWTU:ETPT,5,0:1B2-6; ZWTU:ETPT,5,1:1B2-9;

Create ETPT plug-in unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet

ZWTP:ETPT,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPT,0,1:ETP,0,1;

ZWTP:ETPT,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;ZWTP:ETPT,1,1:ETP,0,6;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ZWTP:ETPT,0,0:ETP,0,1::ETPCS,8,320&&383,TSL,0&&31:ETPPS,8,448&&511,TSL,0&&31::;ZWTP:ETPT,0,1:ETP,0,1;ZWTP:ETPT,1,0:ETP,0,6::ETPCS,8,1856&&1919,TSL,0&&31:ETPPS,8,1792&&1855,TSL,0&&31::;ZWTP:ETPT,1,1:ETP,0,6;

ZWTP:ETPT,2,0:ETP,0,1::ETPCS,8,1600&&1663,TSL,0&&31:ETPPS,8,1344&&1407,TSL,0&&31::;ZWTP:ETPT,2,1:ETP,0,1;ZWTP:ETPT,3,0:ETP,0,6::ETPCS,8,1664&&1727,TSL,0&&31:ETPPS,8,1728&&1791,TSL,0&&31::;ZWTP:ETPT,3,1:ETP,0,6;ZWTP:ETPT,4,0:ETP,0,1::ETPCS,8,64&&127,TSL,0&&31:ETPPS,8,192&&255,TSL,0&&31::;ZWTP:ETPT,4,1:ETP,0,1;ZWTP:ETPT,5,0:ETP,0,6::ETPCS,8,1088&&1151,TSL,0&&31:ETPPS,8,1216&&1279,TSL,0&&31::;ZWTP:ETPT,5,1:ETP,0,6;

Note:For legacy A-interface: Hotlinks are connected from port 0&1 to GSWs. ETPCS functionality is created in plugin unit to support legacy A interface.For A over IP: Traffic will be routed though EEP interface created (via ETPA card).

Page 194: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

194 (270)

For PS via PCU2_E cards: No separate PCMs are required. This will use PEPeth link created in ETP cards tocommunicate with PCU2_E cards in BCSU. This will support CS calls in (A over IP,A over TDM) and PS calls ifPCU2_E cards are used in BSCs.For PS via PCU2_D cards: Hotlinks are connected from port 2&2 to GSWs. ETPPS functionality is created inplug in unit to support PS calls via PCU2_D cards(PEP HDLC link).This will support CS calls in (A over IP,A over TDM) and PS calls if PCU2_E or PCU2_D cards are used in BSCs

Connect functional units ZWUC:ETPT,<pair_number>,<unit_index>:ETP,0:IF=ABIS:;

Create ETS2 functional unit (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000 /Upgraded Flexi Single cabinetSTMU-14 for ETPT 0-0 and ETPT 1-0ZWTU:STMU,14:1A5-6;

STMU-15 for ETPT 0-1 and ETPT 1-1ZWTU:STMU,15:1A5-9;

For BSC 3i 2000 /Upgraded Flexi Double cabinet STMU-14 for ETPT 0-1 and ETPT 1-1 ZWTU:STMU,14:1A5-6;

STMU-15 for ETPT 0-0 and ETPT 1-0 ZWTU:STMU,15:1A5-9;

STMU-4 for ETPT 2-1 and ETPT 3-0ZWTU:STMU,4:1A5-6;

STMU-5 for ETPT 2-0 and ETPT 3-1ZWTU:STMU,5:1A5-9;

STMU-6 for ETPT 4-0 and ETPT 5-0ZWTU:STMU,6:1A5-6;

STMU-7 for ETPT 4-1 and ETPT 5-1ZWTU:STMU,7:1A5-9;

Create ETS2 plug-in unit (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinetSTMU-14 for ETPT 0-0 and ETPT 1-0ZWTP:STMU,14:ETS2,0,8::LAPD,8,643,TSL,16&&31:;

STMU-15 for ETPT 0-1 and ETPT 1-1ZWTP:STMU,15:ETS2,0,8::LAPD,8,899,TSL,16&&31:;

For BSC 3i 2000/Upgraded Flexi Double cabinetSTMU-14 for ETPT 0-1 and ETPT 1-1ZWTP:STMU,14:ETS2,0,8::LAPD,8,643,TSL,16&&31:;

STMU-15 for ETPT 0-0 and ETPT 1-0ZWTP:STMU,15:ETS2,0,8::LAPD,8,899,TSL,16&&31:;

STMU-4 for ETPT 2-1 and ETPT 3-0ZWTP:STMU,4:ETS2,0,3::LAPD,8,641,TSL,0&&15:;

STMU-5 for ETPT 2-0 and ETPT 3-1ZWTP:STMU,5:ETS2,0,3::LAPD,8,897,TSL,0&&15:;

Page 195: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

195 (270)

STMU-6 for ETPT 4-0 and ETPT 5-0ZWTP:STMU,6:ETS2,0,4::LAPD,8,641,TSL,16&&31:;

STMU-7 for ETPT 4-1 and ETPT 5-1ZWTP:STMU,7:ETS2,0,4::LAPD,8,897,TSL,16&&31:;

Create ETs functional units in ETS2, If ETSI ( ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0, ETPT 0-1(ET creation for STMU-14 IF=1)ZWTU:ET, 320&&382:1A5-6:UNIT=STMU,IND=14,IF=1:;

For ETPT 1-0, ETPT 1-1(ET creation for STMU 14 IF=0)ZWTU:ET, 1856&&1918:1A5-6:UNIT=STMU,IND=14,IF=0:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1(ET creation for STMU-14 IF=1)ZWTU:ET, 320&&382:1A5-6:UNIT=STMU,IND=14,IF=1:;

For ETPT 1-0,ETPT 1-1(ET creation for STMU-14 IF=0)ZWTU:ET,1856&&1918:1A5-6:UNIT=STMU,IND=14,IF=0:;

For ETPT 2-0,ETPT2-1(ET creation for STMU-4 IF=1)ZWTU:ET,1600&&1662:1A5-6:UNIT=STMU,IND=4,IF=1:;

For ETPT 3-0,ETPT 3-1(ET Creation for STMU-4 IF=0)ZWTU:ET,1664&&1726:1A5-6:UNIT=STMU,IND=4,IF=0:;

For ETPT 4-0,ETPT4-1(ET creation for STMU-6 IF=1)ZWTU:ET,64&&126:1A5-6:UNIT=STMU,IND=6,IF=1:;

For ETPT 5-0,ETPT 5-1(ET Creation for STMU-6 IF=0)ZWTU:ET,1088&&1150:1A5-6:UNIT=STMU,IND=6,IF=0:;

Create ETs functional units in ETS2, If ANSI

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0, ETPT 0-1(ET creation for STMU-14 IF=1)ZWTU:ET, 2216&&2299:1A5-6:UNIT=STMU,IND=14,IF=1:;

For ETPT 1-0, ETPT 1-1(ET creation for STMU 14 IF=0)ZWTU:ET, 3140&&3223:1A5-6:UNIT=STMU,IND=14,IF=0:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1(ET creation for STMU-14 IF=1)ZWTU:ET, 2216&&2299:1A5-9:UNIT=STMU,IND=14,IF=1:;

For ETPT 1-0,ETPT 1-1(ET creation for STMU-14 IF=0)ZWTU:ET, 3140&&3223:1A5-9:UNIT=STMU,IND=14,IF=0:;

For ETPT 2-0,ETPT2-1(ET creation for STMU-4 IF=1)ZWTU:ET, 2804&&2887:1A5-6:UNIT=STMU,IND=4,IF=1:;

Page 196: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

196 (270)

For ETPT 3-0,ETPT 3-1(ET Creation for STMU-4 IF=0)ZWTU:ET, 2888&&2971:1A5-6:UNIT=STMU,IND=4,IF=0:;

For ETPT 4-0,ETPT 4-1(ET creation for STMU-6 IF=1)ZWTU:ET, 2048&&2131:1A5-6:UNIT=STMU,IND=6,IF=1:;

For ETPT 5-0,ETPT 5-1(ET Creation for STMU-6 IF=0)ZWTU:ET, 2384&&2467:1A5-6:UNIT=STMU,IND=6,IF=0:;

Create ETs Plug in units in ETS2, If ETSI (for BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0, ETPT 0-1 (ET creation for STMU-14 IF=1)ZWTP:ET, 320&&382,:ETS2,0,8::GENERAL,8, 320&&382,NO:;

For ETPT 1-0, ETPT 1-1(ET creation for STMU 14 IF=0)ZWTP:ET,1856 &&1918,:ETS2,0,8::GENERAL,8, 1856&&1918,NO:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1(ET creation for STMU-14 IF=1)ZWTP:ET, 320&&382,:ETS2,0,8::GENERAL,8, 320&&382,NO:;

For ETPT 1-0,ETPT 1-1(ET creation for STMU-14 IF=0)ZWTP:ET,1856 &&1918,:ETS2,0,8::GENERAL,8, 1856&&1918,NO:;

For ETPT 2-0,ETPT2-1(ET creation for STMU-4 IF=1)ZWTP:ET,1600&&1662,:ETS2,0,3::GENERAL,8, 1600&&1662,NO:;

For ETPT 3-0,ETPT 3-1(ET Creation for STMU-4 IF=0)ZWTP:ET,1664 &&1726,:ETS2,0,3::GENERAL,8, 1664&&1726,NO:;

For ETPT 4-0,ETPT4-1(ET creation for STMU-6 IF=1)ZWTP:ET,64&&126,:ETS2,0,4::GENERAL,8, 64&&126,NO:;

For ETPT 5-0,ETPT 5-1(ET Creation for STMU-6 IF=0)ZWTP:ET,1088 &&1150,:ETS2,0,4::GENERAL,8,1088&&1150,NO:;

Create ETs plug in units in ETS2, If ANSI

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0, ETPT 0-1(ET creation for STMU-14 IF=1) ZWTP:ET, 2216&&2299,:ETS2,0,8::GENERAL,8, 2216&&2299,NO:;

For ETPT 1-0, ETPT 1-1(ET creation for STMU 14 IF=0) ZWTP:ET,3140 &&3223,:ETS2,0,8::GENERAL,8, 3140&&3223,NO:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1(ET creation for STMU-14 IF=1) ZWTP:ET, 2216&&2299,:ETS2,0,8::GENERAL,8, 2216&&2299,NO:;

For ETPT 1-0,ETPT 1-1(ET creation for STMU-14 IF=0)ZWTP:ET,3140 &&3223,:ETS2,0,8::GENERAL,8, 3140&&3223,NO:;

Page 197: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

197 (270)

For ETPT 2-0,ETPT2-1(ET creation for STMU-4 IF=1)ZWTP:ET, 2804&&2887,:ETS2,0,3::GENERAL,8, 2804&&2887,NO:;

For ETPT 3-0,ETPT 3-1(ET Creation for STMU-4 IF=0)ZWTP:ET,2888 &&2971,:ETS2,0,3::GENERAL,8, 2888&&2971,NO:;

For ETPT 4-0,ETPT4-1(ET creation for STMU-6 IF=1)ZWTP:ET,2048&&2131,:ETS2,0,4::GENERAL,8, 2048&&2131,NO:;

For ETPT 5-0,ETPT 5-1(ET Creation for STMU-6 IF=0)ZWTP:ET,2384&&2467,:ETS2,0,4::GENERAL,8, 2384&&2467,NO:;

Connect STMUs( For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC3i 1000 / Upgraded Flexi Single cabinet

ZWUC:STMU,14:ETS2,0::BCSU,<index>:;ZWUC:STMU,15:ETS2,0::BCSU,<index>:;

For BSC3i 2000 /Upgraded Flexi Double cabinet

ZWUC:STMU,14:ETS2,0::BCSU,<index>:;ZWUC:STMU,15:ETS2,0::BCSU,<index>:;ZWUC:STMU,4:ETS2,0::BCSU,<index>:;ZWUC:STMU,5:ETS2,0::BCSU,<index>:;ZWUC:STMU,6:ETS2,0::BCSU,<index>:;ZWUC:STMU,7:ETS2,0::BCSU,<index>:;

Connect ETs, IF ETSI (For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0,ETPT 0-1ZWUC:ET,320&&382:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 1-0,ETPT 1-1ZWUC:ET,1856&&1918:ETS2,0:IF=ABIS:BCSU,<index>;

For BSC3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1ZWUC:ET,320&&382:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 1-0,ETPT 1-1ZWUC:ET,1856&&1918:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 2-0,ETPT 2-1ZWUC:ET,1600&&1662:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 3-0,ETPT 3-1ZWUC:ET,1664&&1726:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 4-0,ETPT 4-1ZWUC:ET,64&&126:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 5-0,ETPT 5-1ZWUC:ET,1088&&1150:ETS2,0:IF=ABIS:BCSU,<index>;

Page 198: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

198 (270)

Connect ETs, IF ANSI

For BSC 3i 1000/2000,Upgraded Flexi Single/Double Cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0,ETPT 0,1ZWUC:ET,2216&&2299:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 1-0,ETPT 1,1ZWUC:ET,3140&&3223:ETS2,0:IF=ABIS:BCSU,<index>;

For BSC3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0,1ZWUC:ET,2216&&2299:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 1-0,ETPT 1,1ZWUC:ET,3140&&3223:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 2-0,ETPT 2,1ZWUC:ET,2804&&2887:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 3-0,ETPT 3,1ZWUC:ET,2888&&2971:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 4-0,ETPT 4,1ZWUC:ET,2048&&2131:ETS2,0:IF=ABIS:BCSU,<index>;

For ETPT 5-0,ETPT 5-1ZWUC:ET,2384&&2467:ETS2,0:IF=ABIS:BCSU,<index>;

Create protection groups.(For BSC3i 1000/2000,Upgraded Flexi Single/Double Cabinet)

For BSC 3i 1000/Upgraded Flexi Single cabinet

For ETPT 0-0,ETPT 0-1ZYWC:,,<BI/UNI>,<APS or MSP>:58,62;

For ETPT 1-0,ETPT 1-1ZYWC:,,<BI/UNI>,<APS or MSP>:56,60;

For BSC 3i 2000/Upgraded Flexi Double cabinet

For ETPT 0-0,ETPT 0-1ZYWC:,,<BI/UNI>,<APS or MSP>:58,62;

For ETPT 1-0,ETPT 1-1ZYWC:,,<BI/UNI>,<APS or MSP>:56,60;

For ETPT 2-0,ETPT 2-1ZYWC:,,<BI/UNI>,<APS or MSP>:18,22;

For ETPT 3-0,ETPT 3-1

Page 199: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

199 (270)

ZYWC:,,<BI/UNI>,<APS or MSP>:16,20;

For ETPT 4-0,ETPT 4-1 ZYWC:,,<BI/UNI>,<APS or MSP>:26,30;

For ETPT 5-0,ETPT 5-1 ZYWC:,,<BI/UNI>,<APS or MSP>:24,28;

For ANSI-APS and ETSI-MSP.

Connect hotlink portsZWTA:GSW,0:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:GSW,1:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:STMU,<Unit index>:ETS2,<PIU_Index>:HOTLINK,<PortIndex>:ETPT,<unit_pair>,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinet

ETPT 0-0 ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPT,0,0:ETP,0:HOTLINK,0:; ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPT,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPT,0,0:ETP,0:HOTLINK,2:; ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPT,0,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,4:; ZWTA:STMU,15:ETS2,0:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,5:;

ETPT 0-1 ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPT,0,1:ETP,0:HOTLINK,0:; ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPT,0,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPT,0,1:ETP,0:HOTLINK,2:; ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPT,0,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,4:; ZWTA:STMU,15:ETS2,0:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,5:;

ETPT 1-0ZWTA:GSW,0:SW256B,7:HOTLINK,3:ETPT,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,3:ETPT,1,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPT,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPT,1,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,5:;

ETPT 1-1

Page 200: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

200 (270)

ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPT,1,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPT,1,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPT,1,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPT,1,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,5:;

For BSC 3i 2000/Upgraded Flexi Double cabinet

ETPT 0-0ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPT,0,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPT,0,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,2:ETPT,0,0:ETP,0:HOTLINK,5:;

ETPT 0-1ZWTA:GSW,0:SW256B,1:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,1:HOTLINK,7:ETPT,0,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,1:HOTLINK,7:ETPT,0,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,3:ETPT,0,1:ETP,0:HOTLINK,5:;

ETPT 1-0ZWTA:GSW,0:SW256B,7:HOTLINK,2:ETPT,1,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,2:ETPT,1,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,0:ETPT,1,0:ETP,0:HOTLINK,5:;

ETPT 1-1ZWTA:GSW,0:SW256B,7:HOTLINK,3:ETPT,1,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,7:HOTLINK,3:ETPT,1,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,7:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,7:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,14:ETS2,0:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,4:;ZWTA:STMU,15:ETS2,0:HOTLINK,1:ETPT,1,1:ETP,0:HOTLINK,5:;

ETPT 2-0ZWTA:GSW,0:SW256B,6:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,1:;

Page 201: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

201 (270)

ZWTA:GSW,0:SW256B,5:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,4:ETS2,0:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,4:;ZWTA:STMU,5:ETS2,0:HOTLINK,2:ETPT,2,0:ETP,0:HOTLINK,5:;

ETPT 2-1ZWTA:GSW,0:SW256B,6:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,5:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,5:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,4:ETS2,0:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,4:;ZWTA:STMU,5:ETS2,0:HOTLINK,3:ETPT,2,1:ETP,0:HOTLINK,5:;

ETPT 3-0ZWTA:GSW,0:SW256B,6:HOTLINK,4:ETPT,3,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,4:ETPT,3,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,6:ETPT,3,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,6:HOTLINK,6:ETPT,3,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,4:ETS2,0:HOTLINK,0:ETPT,3,0:ETP,0:HOTLINK,4:;ZWTA:STMU,5:ETS2,0:HOTLINK,0:ETPT,3,0:ETP,0:HOTLINK,5:;

ETPT 3-1ZWTA:GSW,0:SW256B,6:HOTLINK,5:ETPT,3,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,5:ETPT,3,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,6:HOTLINK,7:ETPT,3,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,6:HOTLINK,7:ETPT,3,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,4:ETS2,0:HOTLINK,1:ETPT,3,1:ETP,0:HOTLINK,4:;ZWTA:STMU,5:ETS2,0:HOTLINK,1:ETPT,3,1:ETP,0:HOTLINK,5:;

ETPT 4-0ZWTA:GSW,0:SW256B,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,6:ETPT,4,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,6:ETPT,4,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,4:;ZWTA:STMU,7:ETS2,0:HOTLINK,2:ETPT,4,0:ETP,0:HOTLINK,5:;

ETPT 4-1ZWTA:GSW,0:SW256B,0:HOTLINK,3:ETPT,4,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,0:HOTLINK,3:ETPT,4,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,0:HOTLINK,7:ETPT,4,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,0:HOTLINK,7:ETPT,4,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,3:ETPT,4,1:ETP,0:HOTLINK,4:;ZWTA:STMU,7:ETS2,0:HOTLINK,3:ETPT,4,1:ETP,0:HOTLINK,5:;

ETPT 5-0ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPT,5,0:ETP,0:HOTLINK,0:;

Page 202: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

202 (270)

ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPT,5,0:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPT,5,0:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPT,5,0:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,0:ETPT,5,0:ETP,0:HOTLINK,4:;ZWTA:STMU,7:ETS2,0:HOTLINK,0:ETPT,5,0:ETP,0:HOTLINK,5:;

ETPT 5-1ZWTA:GSW,0:SW256B,4:HOTLINK,3:ETPT,5,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,3:ETPT,5,1:ETP,0:HOTLINK,1:;

ZWTA:GSW,0:SW256B,4:HOTLINK,7:ETPT,5,1:ETP,0:HOTLINK,2:;ZWTA:GSW,1:SW256B,4:HOTLINK,7:ETPT,5,1:ETP,0:HOTLINK,3:;

ZWTA:STMU,6:ETS2,0:HOTLINK,1:ETPT,5,1:ETP,0:HOTLINK,4:;ZWTA:STMU,7:ETS2,0:HOTLINK,1:ETPT,5,1:ETP,0:HOTLINK,5:;

Configure ETPSIG-M TCP/IP stack configuration for active ETPT(SE-NH).(For example ETPT 0-0)ZQRA:ETPT, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPT, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPT, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M TCP/IP stack configuration for redundant ETPT(SE-NH).(For example ETPT 0-1)ZQRA:ETPT, <pair_number>,<unit_index>::IL0::UP;ZQRA:ETPT, <pair_number>,<unit_index>::IL1::UP;ZQRA:ETPT, <pair_number>,<unit_index>::BOND0,IL0,IL1,::UP:;

Configure ETPSIG-M IP address with parameters PDM to active ETPT BOND0 interface.(For example ETPT 0-0)ZQRN:ETPT,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Configure ETPSIG-M IP address with parameters PDM to redundant ETPT BOND0 interface.(For example ETPT0-1)ZQRN:ETPT,<pair_number>,<unit_index>::BOND0:"<ip_address>",<network_mask_length>,P,IDM:;

Create ETPSIG-C IP address for active ETPT (SE-NH).(For example ETPT 0-0)ZQRN:ETPT,<pair_number>,>unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSIG-CZD2C:M:BCSU,<unit_index>::ETPT,<pair_number>,<unit_index>:::;ZD2C:C,NOR:BCSU,<unit_index>::ETPT,<pair_umber>,<unit_index>:::;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units.For redundant card (For example ETPT 0-1) IUA messaging for ETPSIG-M will be created with same BCSUalready selected for Active card (ETPT 0-0)

Create EL0 IP address to ETPTZQRA:ETPT,<pair_number>,<unit_index>::EL0::UP;ZQRN:ETPT,<pair_number>,<unit_index>::EL0,:"<ip_address>",<network_mask_length>,L,:;

Create EEP interface for traffic between ETPT and ETPAZQRA:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPT,<pair_number>,<unit_index>::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Note: EEP interface creation is required only if A over IP is used.

Page 203: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

203 (270)

Note: In case of BSC 3i 1000/2000 or Upgraded flexi Single cabinet/Double cabinet the following pop upwill occur in macro.

Select the required application to proceed further.

Note: Create the PEP link to ETPGID 0 first if you want to get the ETP object ID for the ETPGID to match inNetAct.

Create PEP interface if PCU2-E’s are in use ZQRA:ETPT, <pair_number>,<unit_index>::<PEP_VLAN>,<VLAN_id>,BOND0,; ZQRN:ETPT,<pair_number>,<unit_index>::<PEP_VLAN>,:”<ip_address>",<network_mask_length>,L,VI:; ZQRP:ETPT, <pair_number>,<unit_index>::<PEP_VLAN>:"<ip_address>":TAG,"PEP":;

Create IM0 IP address to ETPT ZQRA:ETPT,<pair_number>,<unit_index>::IM0::UP; ZQRN:ETPT,<pair_number>,<unit_index>::IM0:"<ip_address>",<network_mask_length>,P,I::;

Create IN0 IP address to ETPT ZQRA:ETPT,<pair_number>,<unit_index>::IN0::UP; ZQRN:ETPT,<pair_number>,<unit_index>::IN0:"<ip_address>",<network_mask_length>,P,I::;

Create route from BCSUs to ETPT.

Note: Route is for OMU/TRXSIG from BCSUs to BTSs.ETPT is the GW towards BTS.

ZQKC:BCSU,<Index>::"< Network IP address >",<Sub net mask> :"<ETPT (IL0/IL1) IP address for C-Plane>":LOG:;

Change state of ETPT to TE-EXZUSC:ETPT,<pair_number>,<unit_index>:SE;ZUSC:ETPT,<pair_number>,<unit_index>:TE;

12.2.3 Check Plug-in unit software

Page 204: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

204 (270)

Note: The flashing does not succeed if the username and password in the ETP card does not match the BSC’susername & password. Refer Appendix 6 to see an example how to update the username & password via ETPservice terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Check the CBUHAN version in BSC package.ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

Page 205: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

205 (270)

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG for ETPT.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG for ETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Page 206: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

206 (270)

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPET.IMG forETPT.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

The redundant card will eSW update will be done in similar way.

12.2.4 Diagnostic

Run diagnostic to the ETPT ZUDU:ETPT,<pair number>,<index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPT to WO-EX ZUSC:ETPT,<pair number>,<index>:WO;

12.2.5 STMU s to WO-EX state

ZUSC:STMU,<STMU index>,SE;ZUSC:STMU,<STMU index>,TE;

Check current boot SW version in STMU and compare it to version that is found from the active SW packageZWDI:UT=STMU,UI=<STMU_index>;

If boot SW versions do not match, these must be upgraded.

Update can be done with following command:

Page 207: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

207 (270)

ZWDR:UT=STMU,UI=<STMU_index>;

Note! This can take from one unit 40-60 minutes. Do not remove the cards or cause power restart whileupdating the boot SW, because the SW can corrupt and only way to recover is to send the PIU to HWS.During updating flash memory of ETS2 all connections will be prevented through that Plug-in unit.

Run diagnostic to STMUZUDU:STMU,<STMU index>::;

Change STMU to WO-EX ZUSC:STMU,<STMU index>,WO;

Check PCU configuration

If Packet Abis interface is also used in PS traffic check PCU configuration. PCU2-D or PCU2-E must be created tothe PCUPAB function that it can carry Packet Abis PS data. For PCU2_E cards PEP interface creation is requiredto support PEP Eth link. These creations are mentioned in the below document.

PCU configuration can be checked with following command:ZWTI:BCSU,<unit_index>;

Use “ BSCPCU HW implementation for PS traffic” procedure if PCU configurations need to change.

ETP- PCU connection. ZESK:ETPT,<pair number>:BCSU,<index>:PCU,<index>:;

Note :This is required for both PCU2_E and PCU2_D cards.

13 A OVER IP (ETPA), PIU TYPE ETP-A

13.1 Creation of ETPA unit

Check the source configuration for overlapping Plug-in units.

Note!Macro asks in this point Plug-in Unit location. After that macro check possible unit overlapping.

If there is overlapping plug-in unit’s macro remove them automatically.

Note:- Refer Appendix2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

13.1.1 Install Plug-in units and cables

13.1.1.1 Terminators and setting modules

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinetTerminators and setting modules

Page 208: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

208 (270)

Position ID Name FU Cabinet Use ETPAIndex

Note

5.6B 034E

C108691 ADMOD04 GTIC0

BSCC For ETP-A ETPA 0 1)

5.9B 034E

C108691 ADMOD04 GTIC1

BSCC For ETP-A ETPA 1 1)

5.6B09.2J

C101501 CABID1A GTIC0

BSCC Cabinetidentification

ETPA 0

5.6B09.2L

C101557 CARID53 GTIC0

BSCC Cartridgeidentification

ETPA 0

5.9B09.2J

C101501 CABID1A GTIC1

BSCC Cabinetidentification

ETPA 1

5.9B09.2L

C101558 CARID54 GTIC1

BSCC Cartridgeidentification

ETPA 1

Notes:1) When ETP-A PIU is used as ETPA in this slot

For BSC 3i 2000/Upgraded Flexi Double cabinet

Terminators and setting modulesPosition ID Name FU Cabinet Use ETPA

IndexNote

2.0B 034E

C108691 ADMOD04 ETC 2BSCD For ETP-A

ETPA 2 1)

2.3B 034E

C108691 ADMOD04 ETC 3BSCD For ETP-A

ETPA 3 1)

2.6B 034E

C108691 ADMOD04 ETC 4BSCD For ETP-A

ETPA 0 1)

2.9B 034E

C108691 ADMOD04 ETC 5BSCD For ETP-A

ETPA 1 1)

2.0B09.2J

C101502 CABID1B ETC 2BSCD

Cabinetidentification

ETPA 2

2.0B09.2L

C101535 CARID20 ETC 2BSCD

Cartridgeidentification

ETPA 2

2.3B09.2J

C101502 CABID1B ETC 3BSCD

Cabinetidentification

ETPA 3

2.3B09.2L

C101536 CARID21 ETC 3BSCD

Cartridgeidentification

ETPA 3

2.6B09.2J

C101502 CABID1B ETC 4BSCD

Cabinetidentification

ETPA 0

2.6B09.2L

C101538 CARID23 ETC 4BSCD

Cartridgeidentification

ETPA 0

2.9B09.2J

C101502 CABID1B ETC 5BSCD

Cabinetidentification

ETPA 1

2.9B09.2L

C101539 CARID24 ETC 5BSCD

Cartridgeidentification

ETPA 1

Notes:

1) When ETP-A PIU is used as ETPA in this slot

Page 209: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

209 (270)

13.1.1.2 Plug-in unit installation

For BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet

For BSC 3i 1000/Upgraded Flexi Single cabinet

CartridgeSGC1C position

Unit Cartridge /Slots

ETPAgroupindex

5.6 GTIC-0 3

0

5.9 GTIC-1 3

1

Note:Check Appendix 5 for ETP strappings

For BSC 3i 2000/Upgraded Flexi Double cabinet

CartridgeSGC1C position

Unit Cartridge /Slots

ETPAgroupindex

2.0 ETC-2 3 22.3 ETC-3 3 32.6 ETC-4 3 02.9 ETC-5 3 1

Note:Check Appendix 5 for ETP strappings

Page 210: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

210 (270)

13.1.1.3 Cabling

13.1.1.3.1 Change SWU-0, SWU-2, SWU-4 and SWU-6 SE-NH state

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

13.1.1.3.1.1 For BSC 3i 1000/2000

13.1.1.3.1.1.1 For BSC 3i 1000

Added ETPLAN from LANU-0 for the required tracks

Equipping CABLE FROM CABLE TOETPAINDEXNo FU Position FU Position Type Use Note

Page 211: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

211 (270)

BSCC_4401 LANU0

5.0B05.2G

GTIC0

5.6B03.4G

CHES008 ETPLANETPA-0

BSCC_4404 LANU0

5.0B05.2N

GTIC1

5.9B03.4G

CHES010 ETPLANETPA-1

13.1.1.3.1.1.2 For BSC 3i 2000

Added ETPLAN from LANU-0 for the required tracks

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPAIndex

BSCC_4301 LANU0

5.0B05.1C

BSCCETC2

2.0B03.4G

BSCD CHES044 ETPLANETPA-2

BSCC_4304 LANU0

5.0B05.1J

BSCCETC3

2.3B03.4G

BSCD CHES043 ETPLANETPA-3

BSCC_4415 LANU0

5.0B05.2G

BSCC ETC4

2.6B03.4G

BSCD CHES041 ETPLAN ETPA-0

BSCC_4416 LANU0

5.0B05.2N

BSCC ETC5

2.9B03.4G

BSCD CHES041 ETPLAN ETPA-1

13.1.1.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet

13.1.1.3.1.2.1 For upgraded flexi BSC Single cabinet.

Added ETPLAN from LANU-0 for the required tracks

Equipping CABLE FROM CABLE TOETPAIndexNo FU Position FU Position Type Use Note

BSCC_4401 LANU 0 1.8B05.2J

GTIC 0 5.6B03.4G

CHES023 ETPLANETPA-0

BSCC_4404 LANU 0 1.8B05.2P

GTIC 1 5.9B03.4G

CHES021 ETPLANETPA-1

13.1.1.3.1.2.2 For upgraded flexi BSC Double cabinet.

Added ETPLAN from LANU-0 for the required tracks

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPAIndex

BSCC_4301 LANU0

1.8B05.1E

BSCCETC2

2.0B03.4G

BSCD CHES021 ETPLANETPA-2

BSCC_4304 LANU0

1.8B05.1L

BSCCETC3

2.3B03.4G

BSCD CHES024 ETPLANETPA-3

Page 212: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

212 (270)

BSCC_4415 LANU0

1.8B05.2G

BSCC ETC4

2.6B03.4G

BSCD CHES029 ETPLAN ETPA-0

BSCC_4416 LANU0

1.8B05.2N

BSCC ETC5

2.9B03.4G

BSCD CHES031 ETPLAN ETPA-1

13.1.1.3.2 Change SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;

13.1.1.3.3 Change SWU-1, SWU-3, SWU-5 and SWU-7 SE-NH state

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;ZUSC:SWU,3:SE;

ZUSC:SWU,5:TE;ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

13.1.1.3.3.1 For initial BSC 3i 1000/2000

13.1.1.3.3.1.1 For BSC 3i 1000

Added ETPLAN from LANU-1 for required tracks.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note ETPAIndex

BSCC_4407 LANU1

5.2B05.2G

GTIC0

5.6B03.4J

CHES007 ETPLAN ETPA-0

BSCC_4410 LANU1

5.2B05.2N

GTIC1

5.9B03.4J

CHES009 ETPLAN ETPA-1

Page 213: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

213 (270)

13.1.1.3.3.1.2 For BSC 3i 2000

Added ETPLAN from LANU-1 for required tracks

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPAIndex

BSCC_4311 LANU1

5.2B05.1C

BSCCETC2

2.0B03.4J

BSCD CHES042 ETPLAN ETPA-2

BSCC_4314 LANU1

5.2B05.1J

BSCCETC3

2.3B03.4J

BSCD CHES041 ETPLAN ETPA-3

BSCC_4417 LANU1

5.0B05.2G

BSCC ETC4

2.6B03.4J

BSCD CHES041 ETPLAN ETPA-0

BSCC_4418 LANU1

5.0B05.2N

BSCC ETC5

2.9B03.4J

BSCD CHES041 ETPLAN ETPA-1

13.1.1.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet

13.1.1.3.3.2.1 For upgraded flexi BSC Single cabinet.

Added ETPLAN from LANU-1 for required tracks.

Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note ETPAIndex

BSCC_4407 LANU1

1.10B05.2J

GTIC0

5.6B03.4J

CHES022 ETPLANETPA-0

BSCC_4410 LANU1

1.10B05.2P

GTIC1

5.9B03.4J

CHES020 ETPLANETPA-1

13.1.1.3.3.2.2 For upgraded flexi BSC Double cabinet.

Added ETPLAN from LANU-1 for required tracks

Equipping CABLE FROM CABLE TO

No FUPosition

Cabinet FUPosition

Cabinet Type Use NoteETPAIndex

BSCC_4311 LANU1

1.10B05.1E

BSCCETC2

2.0B03.4J

BSCD CHES023 ETPLAN ETPA-2

BSCC_4314 LANU1

1.10B05.1L

BSCCETC3

2.3B03.4J

BSCD CHES026 ETPLAN ETPA-3

BSCC_4417 LANU1

1.10B05.2G

BSCC ETC4

2.6B03.4J

BSCD CHES029 ETPLAN ETPA-0

BSCC_4418 LANU1

1.10B05.2N

BSCC ETC5

2.9B03.4J

BSCD CHES031 ETPLAN ETPA-1

Page 214: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

214 (270)

13.1.1.3.4 Change SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:SWU,1:SE;ZUSC:SWU,1:TE;ZUSC:SWU,1:WO;

ZUSC:SWU,3:SE;ZUSC:SWU,3:TE;ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE;ZUSC:SWU,5:TE; ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE;ZUSC:SWU,7:TE;ZUSC:SWU,7:WO;

13.1.2 Create HW configuration

Create cartridges if not exist (ini BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet)

GTIC-0 cartridge:ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

GTIC-1 catridge:ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 catridge: ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 catridge: ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 catridge: ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 catridge: ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

Create ETPA functional unit (ini BSC 3i 1000/2000).

BSC 3i 1000/Upgraded flexi Single cabinetZWTU:ETPA,0:1A5-6;ZWTU:ETPA,1:1A5-9;

BSC 3i 2000/Upgraded Flexi Double cabinetZWTU:ETPA,0:1B2-6;ZWTU:ETPA,1:1B2-9;ZWTU:ETPA,2:1B2-0;ZWTU:ETPA,3:1B2-3;

Create ETPA Plug-in unit( ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

BSC 3i 1000 /Upgraded Flexi Single cabinetZWTP:ETPA,0:ETP_A,0,3;ZWTP:ETPA,1:ETP_A,0,3;

Page 215: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

215 (270)

BSC 3i 2000/Upgraded Flexi Double cabinetZWTP:ETPA,0:ETP_A,0,3;ZWTP:ETPA,1:ETP_A,0,3;ZWTP:ETPA,2:ETP_A,0,3;ZWTP:ETPA,3:ETP_A,0,3;

Create interfaces to ETPAZQRA:ETPA,<unit_index>::IL0;ZQRA:ETPA,<unit_index>::IL1;ZQRA:ETPA,<unit_index>::BOND0,IL0,IL1,;

Configure ETPSIG-M IP address to BOND0 interface.ZQRN:ETPA,<unit_index>::BOND0:"<IP_address>",<network_mask_ length>,P,IDM:;

Create ETPSIG-C IP address to BOND0 interface.ZQRN:ETPA,<unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSG-CZD2C:M:BCSU,<unit_index>::ETPA,<unit_index>:::;ZD2C:C,NOR:BCSU,<unit_index>::ETPA,<unit_index>:::;

ExampleZD2C:M:BCSU,0::ETPA,0:::;ZD2C:C,NOR:BCSU,0::ETPA,0:::;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units

Create EL0 IP address to the ETPAZQRA:ETPA,<unit_index>::EL0::UP:;ZQRN:ETPA,<unit_index>::EL0,:"<ip_address>",<net_mask_ length>,P:;

Create EEP interface for traffic between ETPA and ETPE/TZQRA:ETPA,0::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPA,0::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPA,0::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Create static route for ETPAZQKC:ETPA,<unit index>:::"<Gateway ip address>":PHY:;

Create route to BTS from ETPA.ZQKC:ETPA,<Index>::"<IP Adress>",<Subnet mask>:"<GW IP address>":LOG;

Note: IP address should be BCF U-plane IP address. And GW IP address should beETPE/ETPT EEP address.

Change state of ETPA to TE-EXZUSC:ETPA,<unit_index>:SE,FCD;ZUSC:ETPA,<unit_index>:TE,FCD;

13.1.3 Check Plug-in unit software

Note: The flashing does not succeed if the username and password in the ETP card does not match the BSC’susername & password. Refer Appendix 6 to see an example how to update the username & password via ETPservice terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Page 216: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

216 (270)

Check the CBUHAN version in BSC package.ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Page 217: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

217 (270)

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAA.IMG forETPA.

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Page 218: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

218 (270)

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

13.1.4 Diagnostic

Run diagnostic to the ETPAZUDU:ETPA,<unit_index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPA to WO-EXZUSC:ETPA,<unit index>:WO;

Note:-Create the MSS/MGW configurations.Feature 1753 can be turned ON with the below command onceMSS/MGW configurations are completed.

- ZW7M: FEA=1753:ON; (Ao IP, TC in MGW)

Page 219: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

219 (270)

14 A OVER IP (ETPA), PIU TYPE ETP

14.1 Creation of ETP(A) unit

Note!This procedure can be used by adding ETP for Aover IP or by swapping the existing ETP-A with ETP in A over IP.This implementation of A over IP(ETPA),PIU type ETP will be supported from software S15 EP2.1. !

ETP card used for implementation should be manufactured from week 43/2011 onwards.This can beverified from serial number placed on ETP card.

Example,In PIU label if S/N is 4H112063961 then card is manufactured on week 20/2011.

The other option is to recomission the ETP PIU type manufactured before week 43/2011 with S15 EP2.1 or newercomissioning SW. The SW can be found in LFILES directory and name of the module is GGNCOMAB.IMG. Therecomissioning instructions can be found from S15 Release documentation ZIP file named as ETP and ETP-APlug-in unit recomissoining instructions.zip

14.1.1 Check the source configuration for overlapping Plug-in units

Note!Macro asks in this point Plug-in Unit location. After that macro check possible unit overlapping

If there is overlapping plug-in unit’s macro remove them automatically.

Note:- Refer Appendix2,3 to check overlapping PCMs used by existing units in BSCs. Please note to shiftexisting traffic from the plug in unit. Once traffic is shifted remove the units and cables and then insert ETP cardsto required tracks. Please note to turn off jumper settings in GSW units if PCMs are not used. Refer Appendix 1 tocheck jumpers settings used for existing ETP cards.

14.1.2 Deleting the interface and unit In case the upgrade is done to swap existing ETP-A with ETP

Note:- In case the ETP-A is swapped with ETP, ETPLAN cables should be kept back to the track.

Note:- Remove PCMC8A connectors in case of new delivery Flexi and ADMOD23 terminators in caseETS2/ETIP’s are in use.

In this step traffic needs to be shifted from existing ETP-A card manually.

Macro will delete interfaces, plugin unit and unit of existing ETP-A card which needs to be swapped.

14.1.3 Install Plug-in units and cables

14.1.3.1 Terminators and setting modules

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

For BSC 3i 1000.

Remove following Terminators and modulesPosition ID Name FU Use Note

5.6B 034E

C108691 ADMOD04 GTIC 0 For ETP-Aused asETPA

1)

Page 220: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

220 (270)

5.9B 034E

C108691 ADMOD04 GTIC 1 For ETP-Aused asETPA

1)

Notes:1) To be removed only if PIU ETP-A is replaced by PIU ETP.

Add following Terminators and setting modulesPosition ID Name FU Use ETP(A)

IndexNote

5.6B 034E

C108689 ADMOD02 GTIC 0 For ETPused asETP(A)

ETP(A)0

1)

5.9B 034E

C108689 ADMOD02 GTIC 1 For ETPused asETP(A)

ETP(A)1

1)

5.6B09.2J

C101501 CABID1A GTIC 0 Cabinetidentification

ETP(A)0

5.6B09.2L

C101557 CARID53 GTIC 0 Cartridgeidentification

ETP(A)0

5.9B09.2J

C101501 CABID1A GTIC 1 Cabinetidentification

ETP(A)1

5.9B09.2L

C101558 CARID54 GTIC 1 Cartridgeidentification

ETP(A)1

For Upgraded Flexi Single cabinet.

Remove following Terminators and modules

Position ID Name FU Use Note

5.6B 034E

C108691 ADMOD04 GTIC 0 For ETP-Aused asETPA

1)

5.9B 034E

C108691 ADMOD04 GTIC 1 For ETP-Aused asETPA

1)

Notes:1) To be removed only if PIU ETP-A is replaced by PIU ETP.

Add following Terminators and setting modules

Position ID Name FU Use ETP(A)Index

Note

5.6B 034E

C108689 ADMOD02 GTIC 0 For ETP usedas ETP(A) ETP(A) 0

1)

5.9B 034E

C108689 ADMOD02 GTIC 1 For ETP usedas ETP(A) ETP(A) 1

1)

5.0B 024E

C108689 ADMOD02 GTIC 2 For ETP usedas ETP(A) ETP(A) 2 2)

Page 221: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

221 (270)

5.2B 024E

C108689 ADMOD02 GTIC 3 For ETP usedas ETP(A) ETP(A) 3 2)

5.6B09.2J

C101501 CABID1A GTIC 0 Cabinetidentificationfor ETP(A)

ETP(A) 0

5.6B09.2L

C101557 CARID53 GTIC 0 Cartridgeidentificationfor ETP(A)

ETP(A) 0

5.9B09.2J

C101501 CABID1A GTIC 1 Cabinetidentificationfor ETP(A)

ETP(A) 1

5.9B09.2L

C101558 CARID54 GTIC 1 Cartridgeidentificationfor ETP(A)

ETP(A) 1

5.0B05.3J

C101501 CABID1A GTIC2 Cabinetidentificationfor ETP(A)

ETP(A) 2

5.0B05.3L

C101554 CARID50 GTIC 2 Cartridgeidentificationfor ETP(A)

ETP(A) 2

5.2B05.3J

C101501 CABID1A GTIC 3 Cabinetidentificationfor ETP(A)

ETP(A) 3

5.2B05.3L

C101555 CARID51 GTIC 3 Cartridgeidentificationfor ETP(A)

ETP(A) 3

Notes:When ETP-(A) PIU is used in this slot.ETP-(A) PIU is used in this slot if upgraded flexi is upgraded with GTIC-2 and GTIC-3 instead of BCSU-6.

For BSC 3i 2000/Upgraded flexi double cabinet.

Remove following Terminators and modules

Position ID Name FU Use Note

2.0B 034E

C108691 ADMOD04 ETC 2 For ETP-Aused asETPA

1)

2.3B 034E

C108691 ADMOD04 ETC 3 For ETP-Aused asETPA

1)

2.6B 034E

C108691 ADMOD04 ETC 4 For ETP-Aused asETPA

1)

2.9B 034E

C108691 ADMOD04 ETC 5 For ETP-Aused asETPA

1)

Notes:1) To be removed only if PIU ETP-A is replaced by PIU ETP.

Add following Terminators and setting modules.

Position ID Name FU Use Note ETP(A)Index

2.0B 034E

C108689 ADMOD02 ETC 2 For ETPused as

1) ETP(A) 2

Page 222: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

222 (270)

ETP(A)

2.3B 034E

C108689 ADMOD02 ETC 3 For ETPused asETP(A)

1)ETP(A) 3

2.6B 034E

C108689 ADMOD02 ETC 4 For ETPused asETP(A)

1)ETP(A) 0

2.9B 034E

C108689 ADMOD02 ETC 5 For ETPused asETP(A)

1)ETP(A) 1

2.0B09.2J

C101502 CABID1B ETC 2 Cabinetidentification ETP(A) 2

2.0B09.2L

C101535 CARID20 ETC 2 Cartridgeidentification ETP(A) 2

2.3B09.2J

C101502 CABID1B ETC 3 Cabinetidentification ETP(A) 3

2.3B09.2L

C101536 CARID21 ETC 3 Cartridgeidentification ETP(A) 3

2.6B09.2J

C101502 CABID1B ETC 4 Cabinetidentification ETP(A) 0

2.6B09.2L

C101538 CARID23 ETC 4 Cartridgeidentification ETP(A) 0

2.9B09.2J

C101502 CABID1B ETC 5 Cabinetidentification ETP(A) 1

2.9B09.2L

C101539 CARID24 ETC 5 Cartridgeidentification ETP(A) 3

Notes:1) When ETP-(A) PIU is used in this slot

14.1.3.2 Plug-in unit installation

For BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet

For BSC 3i 1000

CartridgeSGC1C position

Unit Cartridge /Slots

ETP(A)groupindex

5.6 GTIC-0 3

0

5.9 GTIC-1 3

1

Note:Check Appendix 5 for ETP strappings

Page 223: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

223 (270)

For Upgraded flexi Single cabinet.

CartridgeSGC1Cposition

Unit Cartridge/ Slots

ETP(A)groupindex

5.6 GTIC 0 3 0

5.9 GTIC 1 3 1

5.0 GTIC 2 2 2

5.3 GTIC 3 2 3

Note:Check Appendix 5 for ETP strappings

Page 224: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

224 (270)

NOTE!!This option is only used if upgraded Flexi BSC is equipped with GTIC-2 & 3 instead ofBCSU- 6

For BSC 3i 2000/Upgraded Flexi Double cabinet

CartridgeSGC1C position

Unit Cartridge /Slots

ETP(A)groupindex

2.0 ETC-2 3 22.3 ETC-3 3 32.6 ETC-4 3 02.9 ETC-5 3 1

Note:Check Appendix 5 for ETP strappings

Page 225: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

225 (270)

14.1.3.3 Cabling

14.1.3.3.1 Change MCMU,0 SWU-0, SWU-2, SWU-4 and SWU-6 SE-NH state

ZUSC:MCMU,0:SP; If neededZUSC:MCMU,0:TE;ZUSC:MCMU,0:SE;ZUSC:MCMU,0:SE;

ZUSC:EMB,0:SP; If neededZUSC:EMB,0:TE;ZUSC:EMB,0:SE;ZUSC:EMB,0:SE;

ZUSC:SWU,0:TE;ZUSC:SWU,0:SE;ZUSC:SWU,0:SE;

ZUSC:SWU,2:TE;ZUSC:SWU,2:SE;ZUSC:SWU,2:SE;

ZUSC:SWU,4:TE;ZUSC:SWU,4:SE;ZUSC:SWU,4:SE;

ZUSC:SWU,6:TE;ZUSC:SWU,6:SE;ZUSC:SWU,6:SE;

14.1.3.3.1.1 For ini BSC 3i 1000/2000

14.1.3.3.1.1.1 For BSC 3i 1000.

Add needed ETPLAN and Hotlink cables from GSW-0 and LANU-0 to required tracks.Equipping CABLE FROM CABLE TO

Page 226: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

226 (270)

No FU Position FU Position Type Use Note ETPAIndex

BSCC_4401 LANU 0 5.0B05.2G

GTIC 0 5.6B03.4G

CHES008 ETPLAN 2)ETPA-0

BSCC_4404 LANU 0 5.0B05.2N

GTIC 1 5.9B03.4G

CHES010 ETPLAN 2)ETPA-1

BSCC_4960 GTIC 0 5.6F04.SB2-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 1)ETP(A) -0

BSCC_4962 GTIC 1 5.9F04.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 1)ETP(A) -1

Notes:These cables are included in partlist, but shall only be connected, if ETP PIU is taken in use as ETP(A) in thisslot(s).

14.1.3.3.1.1.2 For BSC 3i 2000.

Add needed ETPLAN and Hotlink cables from GSW-0 and LANU-0 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position Cabinet

FUPosition

Cabinet

Type Use Note ETPA

IndexBSCC_4301

LANU 0

5.0B05.1C

BSCC ETC 2 2.0B03.4G

BSCD CHES044

ETPLAN

2) ETP(A)-2

BSCC_4304

LANU 0

5.0B05.1J

BSCC ETC 3 2.3B03.4G

BSCD CHES043

ETPLAN

2) ETP(A)-3

BSCC_4415

LANU 0

5.0B05.2G

BSCC ETC 4 2.6B03.4G

BSCD CHES041

ETPLAN 2)

ETP(A)-0

BSCC_4416

LANU 0

5.0B05.2N

BSCC ETC 5 2.9B03.4G

BSCD CHES041

ETPLAN 2)

ETP(A)-1

BSCD0_4965

ETC2

2.0F04.SB2-0

BSCD GSW2KB 0

1.0F02.SB2-0

BSCC CSB025 Hotlink 1)ETP(A)-2

BSCD0_4967

ETC3

2.3F04.SB2-0

BSCD GSW2KB 0

1.0F02.SB4-0

BSCC CSB027 Hotlink 1)ETP(A)-3

BSCD0_4969

ETC4

2.6F04.SB2-0

BSCD GSW2KB 0

1.0F05.SB2-0

BSCC CSB029 Hotlink 1)ETP(A)-0

BSCD0_4971

ETC5

2.9F04.SB2-0

BSCD GSW2KB 0

1.0F05.SB4-0

BSCC CSB031 Hotlink 1)ETP(A)-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s)2) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or having

ET16 or having ETS2 or ETIP

14.1.3.3.1.2 For upgraded flexi BSC Single cabinet/Double cabinet

14.1.3.3.1.2.1 For upgraded flexi BSC Single cabinet.

Page 227: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

227 (270)

Add needed ETPLAN and Hotlink cables from GSW-0 and LANU-0 to required tracks.

Equipping CABLE FROM CABLE TOETP(A)IndexNo FU Position FU Position Type Use Note

BSCC_4401 LANU 0 1.8B05.2J

GTIC 0 5.6B03.4G

CHES023 ETPLAN 3) ETP(A)-0

BSCC_4404 LANU 0 1.8B05.2P

GTIC 1 5.9B03.4G

CHES021 ETPLAN 3) ETP(A)-1

BSCC_4984 LANU 0 1.8B05.1E

GTIC 2 5.0B02.4G

CHES028 ETPLAN 3) ETP(A)-2

BSCC_4985 LANU 0 1.8B05.1L

GTIC 3 5.2B02.4G

CHES028 ETPLAN 3) ETP(A)-3

BSCC_4960 GTIC 0 5.6F04.SB2-0

GSW2KB0

1.0F05.SB2-0

CSB029 Hotlink 1)ETP(A)-0

BSCC_4962 GTIC 1 5.9F04.SB2-0

GSW2KB0

1.0F05.SB4-0

CSB028 Hotlink 1)ETP(A)-1

BSCC_4980 GTIC 2 5.0F03.SB2-0

GSW2KB0

1.0F06.SB1-0

CSB022 Hotlink 2)ETP(A)-2

BSCC_4982 GTIC 3 5.2F03.SB2-0

GSW2KB0

1.0F07.SB1-0

CSB024 Hotlink 2)ETP(A)-3

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s).2) ETP-(A) PIU is used in this slot if upgraded flexi is upgraded with GTIC-2 and GTIC-3 instead of BCSU-

6.3) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or having

ET16 or having ETS2 or ETIP

14.1.3.3.1.2.2 For upgraded flexi BSC Double cabinet.

Add needed ETPLAN and Hotlink cables from GSW-0 and LANU-0 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position Cabinet FUPosition

Cabinet Type Use NoteETP(A)Index

BSCC_4301 LANU0

1.8B05.1E

BSCC ETC 2 2.0B03.4G

BSCD CHES021 ETPLAN 2) ETP(A)-2

BSCC_4304 LANU0

1.8B05.1L

BSCC ETC 3 2.3B03.4G

BSCD CHES024 ETPLAN 2)

ETP(A)-3

BSCC_4415 LANU0

1.8B05.2G

BSCC ETC 4 2.6B03.4G

BSCD CHES029 ETPLAN 2) ETP(A)-0

BSCC_4416 LANU0

1.8B05.2N

BSCC ETC 5 2.9B03.4G

BSCD CHES031 ETPLAN 2) ETP(A)-1

BSCD0_4965

ETC2

2.0F04.SB2-0

BSCD GSW2KB0

1.0F02.SB2-0

BSCC CSB025 Hotlink 1)ETP(A)-2

BSCD0_4967

ETC3

2.3F04.SB2-0

BSCD GSW2KB0

1.0F02.SB4-0

BSCC CSB027 Hotlink 1)ETP(A)-3

Page 228: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

228 (270)

BSCD0_4969

ETC4

2.6F04.SB2-0

BSCD GSW2KB0

1.0F05.SB2-0

BSCC CSB029 Hotlink 1)ETP(A)-0

BSCD0_4971

ETC5

2.9F04.SB2-0

BSCD GSW2KB0

1.0F05.SB4-0

BSCC CSB031 Hotlink 1)ETP(A)-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s).2) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or having

ET16 or having ETS2 or ETIP

Check SW256B dip switching. See appendix1

14.1.3.3.2 Change MCMU-0, SWU-0, SWU-2, SWU-4 and SWU-6 to WO-EX state.

ZUSC:MCMU,0:SE;ZUSC:MCMU,0:TE;ZUSC:MCMU,0:SP;ZUSC:MCMU,0:WO;

ZUSC:EMB,0:SE;ZUSC:EMB,0:TE;ZUSC:EMB,0:SP;ZUSC:EMB:WO;

ZUSC:SWU,0:SE;ZUSC:SWU,0:TE;ZUSC:SWU,0:WO;

ZUSC:SWU,2:SE;ZUSC:SWU,2:TE;ZUSC:SWU,2:WO;

ZUSC:SWU,4:SE;ZUSC:SWU,4:TE;ZUSC:SWU,4:WO;

ZUSC:SWU,6:SE;ZUSC:SWU,6:TE;ZUSC:SWU,6:WO;

14.1.3.3.3 Change MCMU-1, SWU-1, SWU-3, SWU-5 and SWU-7 SE-NH state

ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SE;ZUSC:MCMU,1:SE;

ZUSC:EMB,1:TE;ZUSC:EMB,1:SE;ZUSC:EMB,1:SE;

ZUSC:SWU,1:TE;ZUSC:SWU,1:SE;ZUSC:SWU,1:SE;

ZUSC:SWU,3:TE;ZUSC:SWU,3:SE;

Page 229: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

229 (270)

ZUSC:SWU,3:SE;

ZUSC:SWU,5:TE;ZUSC:SWU,5:SE;ZUSC:SWU,5:SE;

ZUSC:SWU,7:TE;ZUSC:SWU,7:SE;ZUSC:SWU,7:SE;

14.1.3.3.3.1 For initial BSC 3i 1000/2000

14.1.3.3.3.1.1 For BSC 3i 1000.

Add needed ETPLAN and Hotlink cables from GSW-1 and LANU-1 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note ETP(A)Index

BSCC_4961 GTIC0

5.6F04.SB2-1

GSW2KB1

1.3F05.SB2-0

CSB028 Hotlink 1) ETP(A)-0

BSCC_4963 GTIC1

5.9F04.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB027 Hotlink 1) ETP(A)-1

BSCC_4407 LANU1

5.2B05.2G

GTIC 0 5.6B03.4J

CHES007 ETPLAN 2) ETP(A)-0

BSCC_4410 LANU1

5.2B05.2N

GTIC 1 5.9B03.4J

CHES009 ETPLAN 2) ETP(A)-1

Notes:1) These cables are included in partlist, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s).2) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or having

ET16 or having ETS2 or ETIP

14.1.3.3.3.1.2 For BSC 3i 2000

Add needed ETPLAN and Hotlink cables from GSW-1 and LANU-1 to required tracks.

Equipping CABLE FROM CABLE TO

No FU Position Cabinet

FUPosition

Cabinet

Type Use Note ETP(A)

IndexBSCC_4311

LANU 1

5.2B05.1C

BSCC ETC 2 2.0B03.4J

BSCD CHES042

ETPLAN

2) ETP(A)-2

BSCC_4314

LANU 1

5.2B05.1J

BSCC ETC 3 2.3B03.4J

BSCD CHES041

ETPLAN

2) ETP(A)-3

BSCC_4417

LANU 1

5.0B05.2G

BSCC ETC 4 2.6B03.4J

BSCD CHES041

ETPLAN

2) ETP(A)-0

BSCC_4418

LANU 1

5.0B05.2N

BSCC ETC 5 2.9B03.4J

BSCD CHES041

ETPLAN

2) ETP(A)-1

BSCD0_4966

ETC2

2.0F04.SB2-1

BSCD GSW2KB 1

1.3F02.SB2-0

BSCC CSB022 Hotlink 1) ETP(A)-2

Page 230: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

230 (270)

BSCD0_4968

ETC3

2.3F04.SB2-1

BSCD GSW2KB 1

1.3F02.SB4-0

BSCC CSB024 Hotlink 1) ETP(A)-3

BSCD0_4970

ETC4

2.6F04.SB2-1

BSCD GSW2KB 1

1.3F05.SB2-0

BSCC CSB026 Hotlink 1) ETP(A)-0

BSCD0_4972

ETC5

2.9F04.SB2-1

BSCD GSW2KB 1

1.3F05.SB4-0

BSCC CSB028 Hotlink 1) ETP(A)-1

Notes:1)These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETP(A) in thisslot(s).2)Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or having ET16 orhaving ETS2 or ETIP.

14.1.3.3.3.2 For upgraded flexi BSC Single cabinet/Double cabinet

14.1.3.3.3.2.1 For upgraded flexi BSC Single cabinet.’

Move and reconnect or add following cable if required.Equipping

CABLE FROM CABLE TO

No OldFU

OldPosition

NewFU

NewPosition

OldFU

OLDPosition

NewFU

NEWPosition

Type Use Note

ETP(A)Index

BSCC_1064

MCMU 0

2.0B02.2E

LANU 1

1.10B05.1E

BCSU 6

5.0B10.1A

GTIC 2

5.0B02.4J

CHES029

ETPLAN

3) ETP(A)-2

Add needed ETPLAN and Hotlink cables from GSW-1 and LANU-1 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position FU Position Type Use Note ETPAIndex

BSCC_4407 LANU1

1.10B05.2J

GTIC 0 5.6B03.4J

CHES022 ETPLAN 3) ETP(A)-0

BSCC_4410 LANU1

1.10B05.2P

GTIC 1 5.9B03.4J

CHES020 ETPLAN 3) ETP(A)-1

BSCC_4986 LANU1

1.10B05.1L

GTIC 3 5.2B02.4J

CHES029 ETPLAN 3) ETP(A)-3

BSCC_4961 GTIC0

5.6F04.SB2-1

GSW2KB1

1.3F05.SB2-0

CSB028 Hotlink 1) ETP(A)-0

BSCC_4963 GTIC1

5.9F04.SB2-1

GSW2KB1

1.3F05.SB4-0

CSB027 Hotlink 1) ETP(A)-1

BSCC_4981 GTIC2

5.0F03.SB2-1

GSW2KB1

1.3F06.SB1-0

CSB025 Hotlink 2) ETP(A)-2

BSCC_4983 GTIC3

5.2F03.SB2-1

GSW2KB1

1.3F07.SB1-0

CSB027 Hotlink 2) ETP(A)-3

Notes:1) These cables are included in part list, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s).

Page 231: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

231 (270)

2) ETP-(A) PIU is used in this slot if upgraded flexi is upgraded with GTIC-2 and GTIC-3 instead of BCSU-6.

3) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or havingET16 or having ETS2 or ETIP.

14.1.3.3.3.2.2 For upgraded flexi BSC Double cabinet.

Add needed ETPLAN and Hotlink cables from GSW-1 and LANU-1 to required tracks.Equipping CABLE FROM CABLE TO

No FU Position Cabinet

FUPosition

Cabinet

Type Use Note ETP(A)

IndexBSCC_4311

LANU 1

1.10B05.1E

BSCC ETC 2 2.0B03.4J

BSCD CHES023

ETPLAN

2) ETP(A)-2

BSCC_4314

LANU 1

1.10B05.1L

BSCC ETC 3 2.3B03.4J

BSCD CHES026

ETPLAN

2) ETP(A)-3

BSCC_4417

LANU 1

1.10B05.2G

BSCC ETC 4 2.6B03.4J

BSCD CHES029

ETPLAN

2) ETP(A)-0

BSCC_4418

LANU 1

1.10B05.2N

BSCC ETC 5 2.9B03.4J

BSCD CHES031

ETPLAN

2) ETP(A)-1

BSCD0_4966

ETC2

2.0F04.SB2-1

BSCD GSW2KB 1

1.3F02.SB2-0

BSCC CSB022 Hotlink 1) ETP(A)-2

BSCD0_4968

ETC3

2.3F04.SB2-1

BSCD GSW2KB 1

1.3F02.SB4-0

BSCC CSB024 Hotlink 1) ETP(A)-3

BSCD0_4970

ETC4

2.6F04.SB2-1

BSCD GSW2KB 1

1.3F05.SB2-0

BSCC CSB026 Hotlink 1) ETP(A)-0

BSCD0_4972

ETC5

2.9F04.SB2-1

BSCD GSW2KB 1

1.3F05.SB4-0

BSCC CSB028 Hotlink 1) ETP(A)-1

Notes:1) These cables are included in parts list, but shall only be connected, if ETP PIU is taken in use as ETP(A)

in this slot(s).

2) Those ETPLAN cables are only added if the ETP will be add first time to track which is empty or havingET16 or having ETS2 or ETIP.

Check SW256B dip switching. See appendix1

14.1.3.3.4 14.1.3.3.4 Change MCMU-1 to SP-EX state SWU-1, SWU-3, SWU-5 and SWU-7 to WO-EX state.

ZUSC:MCMU,1:SE;ZUSC:MCMU,1:TE;ZUSC:MCMU,1:SP;

ZUSC:EMB,1:SE;ZUSC:EMB,1:TE;ZUSC:EMB,1:SP;

ZUSC:SWU,1:SE;ZUSC:SWU,1:TE;ZUSC:SWU,1:WO;

Page 232: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

232 (270)

ZUSC:SWU,3:SE; ZUSC:SWU,3:TE; ZUSC:SWU,3:WO;

ZUSC:SWU,5:SE; ZUSC:SWU,5:TE; ZUSC:SWU,5:WO;

ZUSC:SWU,7:SE; ZUSC:SWU,7:TE; ZUSC:SWU,7:WO;

14.1.4 Create HW configuration

Create cartridges if not exist (ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)GTIC-0 cartridge:ZWTC:GT4C_A,1A5-6,:AL=1A5-4-2S7;

GTIC-1 catridge: ZWTC:GT4C_A,1A5-9,:AL=1A5-4-3S7;

ETC-2 catridge: ZWTC:GT4C_A,1B2-0,:AL=1B1-10-3S3,;

ETC-3 catridge: ZWTC:GT4C_A,1B2-3,:AL=1B1-10-2S5,;

ETC-4 catridge: ZWTC:GT4C_A,1B2-6,:AL=1B1-10-3S5,;

ETC-5 catridge: ZWTC:GT4C_A,1B2-9,:AL=1B1-10-2S7,;

For Upgraded flexi-single cabinet (if required) GTIC-2 catridge: ZWTC:GT4C_A,1A5-0,:AL=1A5-4-1S7;

GTIC-3 catridge: ZWTC:GT4C_A,1A5-3,:AL=1A5-4-1S7;

NOTE!!This creation is required is only used if upgraded Flexi BSC is equipped with GTIC-2& GTIC-3 instead of BCSU-6.

Create ETPA functional unit (ini BSC 3i 1000/2000,Upgarded flexi Single/Double cabinet))

For BSC 3i 1000ZWTU:ETPA,0:1A5-6;ZWTU:ETPA,1:1A5-9;

For upgraded flexi BSC Single cabinet.ZWTU:ETPA,0:1A5-6;ZWTU:ETPA,1:1A5-9;

NOTE!!This creation for ETPA-2 and ETPA-3 is required is used if upgraded Flexi BSC isequipped with GTIC-2 and GTIC-3 instead of BCSU-6.

ZWTU:ETPA,2:1A5-0;ZWTU:ETPA,3:1A5-3;

Page 233: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

233 (270)

For BSC 3i 2000/Upgraded Flexi Double cabinetZWTU:ETPA,0:1B2-6;ZWTU:ETPA,1:1B2-9;ZWTU:ETPA,2:1B2-0;ZWTU:ETPA,3:1B2-3;

Create ETPA Plug-in unit ( ini BSC 3i 1000/2000,Upgraded Flexi Single/Double cabinet)

For BSC 3i 1000. ZWTP:ETPA,0:ETP,0,3,::ETPACS,8,1088&&1151,TSL,0&&31::; ZWTP:ETPA,1:ETP,0,3,::ETPACS,8,1216&&1279,TSL,0&&31::;

For Upgraded flexi Single cabinet. ZWTP:ETPA,0:ETP,0,3,::ETPACS,8,1088&&1151,TSL,0&&31::; ZWTP:ETPA,1:ETP,0,3,::ETPACS,8,1216&&1279,TSL,0&&31::;

NOTE!! This creation for ETPA-2 and ETPA-3 is required is used if upgraded Flexi BSC is equipped with GTIC-2 and GTIC-3 instead of BCSU-6.

ZWTP:ETPA,2:ETP,0,2,::ETPACS,8,1280&&1343,TSL,0&&31::;ZWTP:ETPA,3:ETP,0,2,::ETPACS,8,1536&&1599,TSL,0&&31::;

For BSC 3i 2000/Upgraded Flexi Double cabinet.ZWTP:ETPA,0:ETP,0,3,::ETPACS,8,1088&&1151,TSL,0&&31::;ZWTP:ETPA,1:ETP,0,3,::ETPACS,8,1216&&1279,TSL,0&&31::;ZWTP:ETPA,2:ETP,0,3,::ETPACS,8,320&&383,TSL,0&&31::;ZWTP:ETPA,3:ETP,0,3,::ETPACS,8,448&&511,TSL,0&&31::;

Connect functional unitsZWUC:ETPA,<unit_index>:ETP,0:IF=A;

Connect hotlink ports ZWTA:GSW,0:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPA,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

ZWTA:GSW,1:SW256B,<PIU_index>:HOTLINK,<port_index>:ETPA,<unit_index>:ETP,<PIU_index>:HOTLINK,<port_index>:;

For BSC 3i 1000/2000, Upgraded Flexi Single/Double cabinet

For BSC 3i 1000.ETP(A)- 0ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,1:;

ETP(A)- 1ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,1:;

For Upgraded flexi Single cabinet.ETP(A)- 0ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,1:;

Page 234: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

234 (270)

ETP(A)- 1ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,1:;

NOTE!!This creation for ETPA-2 and ETPA-3 is required is used if upgraded Flexi BSC isequipped with GTIC-2 and GTIC-3 instead of BCSU-6.

ETP(A)- 2ZWTA:GSW,0:SW256B,5:HOTLINK,0:ETPA,2:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,5:HOTLINK,0:ETPA,2:ETP,0:HOTLINK,1:;

ETP(A)- 3ZWTA:GSW,0:SW256B,6:HOTLINK,0:ETPA,3:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,6:HOTLINK,0:ETPA,3:ETP,0:HOTLINK,1:;

For BSC 3i 2000/Upgraded flexi double cabinet.ETP(A)- 0ZWTA:GSW,0:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,2:ETPA,0:ETP,0:HOTLINK,1:;

ETP(A)- 1ZWTA:GSW,0:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,4:HOTLINK,6:ETPA,1:ETP,0:HOTLINK,1:;

ETP(A)- 2ZWTA:GSW,0:SW256B,1:HOTLINK,2:ETPA,2:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,2:ETPA,2:ETP,0:HOTLINK,1:;

ETP(A)- 3ZWTA:GSW,0:SW256B,1:HOTLINK,6:ETPA,3:ETP,0:HOTLINK,0:;ZWTA:GSW,1:SW256B,1:HOTLINK,6:ETPA,3:ETP,0:HOTLINK,1:;

Create interfaces to ETPA ZQRA:ETPA,<unit_index>::IL0; ZQRA:ETPA,<unit_index>::IL1; ZQRA:ETPA,<unit_index>::BOND0,IL0,IL1,;

Configure ETPSIG-M IP address to BOND0 interface.ZQRN:ETPA,<unit_index>::BOND0:"<IP_address>",<network_mask_ length>,P,IDM:;

Create ETPSIG-C IP address to BOND0 interface. ZQRN:ETPA,<unit_index>::BOND0:"<IP_address>",<network_mask_length>,L,ICV::;

Create IuA messaging configuration for ETPSIG-M and ETPSG-CZD2C:M:BCSU,<unit_index>::ETPA,<unit_index>:::;ZD2C:C,NOR:BCSU,<unit_index>::ETPA,<unit_index>:::;

ExampleZD2C:M:BCSU,0::ETPA,0:::;ZD2C:C,NOR:BCSU,0::ETPA,0:::;

Note!ETPSIG-M is created only to Gateway BCSU and ETPSIG-C must be created to all BCSU’s for all ETP/ETP-A units.

Page 235: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

235 (270)

Create EL0 IP address to the ETPAZQRA:ETPA,<unit_index>::EL0::UP:;ZQRN:ETPA,<unit_index>::EL0,:"<ip_address>",<net_mask_ length>,P:;

Create EEP interface for traffic between ETPA and ETPE/TZQRA:ETPA,<Index>::<EEP_VLAN>,<VLAN_id>,BOND0,;ZQRN:ETPA,<Index>::<EEP_VLAN>,:"<ip_address>",<network_mask_length>,L,VI:;ZQRP:ETPA,<Index>::<EEP_VLAN>:"<ip_address>":TAG,"EEP":;

Create IN0 IP address to ETPAZQRA:ETPA,<unit_index>::IN0::UP;ZQRN:ETPA,<unit_index>::IN0:"<ip_address>",<network_mask_length>,P,I::;

Create static route for ETPAZQKC:ETPA,<unit index>:::"<Gateway ip address>":PHY:;

Create route to BTS from ETPA.ZQKC:ETPA,<Index>::"<IP Adress>",<Subnet mask>:"<GW IP address>":LOG;

Note: IP address should be BCF U-plane IP address. And GW IP address should beETPE/ETPT EEP address.

This is required only in case if packet abis set up exists.

Change state of ETPA to TE-EXZUSC:ETPA,<unit_index>:SE,FCD;ZUSC:ETPA,<unit_index>:TE,FCD;

14.1.5 Check Plug-in unit software

Note: The flashing does not succeed if the username and password in the ETP card does not match theBSC’s username & password. Refer Appendix 6 to see an example how to update the username &password via ETP service terminal.

Check the flash software of ETP cards:-ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Check the CBUHAN version in BSC package.ZDDE::"ZMXP:W0-MMDIRE/CBU*.*";

Macro will choose a valid option (option1 or option2 or option3) based on the output of above interrogationcommands.

Option 1:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISK is newer than PAC versions mentioned below. If CBUHAN version is older than theversion mentioned below, then option 1 needs to be selected.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Page 236: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

236 (270)

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Upgrade the ETP software on the Standby flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Option 2:- When existing ETP version is newer than PAC versions mentioned below and also if CBUHANversion is newer than the version mentioned.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card. This will verifyif flash upgrade was successful.ZUSU:UT=<ETP type>,UI=<index>;

Upgrade the ETP software on the new STANDBY flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ipaddress>,SW=W0-LFILES/<GGNET*_file>,MODE=STANDBY;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Use command ZWDS to switch upgraded flash as ACTIVE flash on the ETP card:ZWDS:UT=<ETP_type>,UI=<index>,PT=<ETP_type>,PI=<index>:;

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card from theoriginal flash.

Page 237: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

237 (270)

ZUSU:UT=<ETP type>,UI=<index>;

Option 3:- When existing ETP version is same or older than the versions mentioned below and ETPsoftware in OMU DISKis also same or older than PAC versions mentioned below.

Image Name PAC Version existing on ETPGGNCOMAB 2.3-0

GGNETPET 3.30-0

GGNETPAA 3.29-0

GGNETPAB 4.29-0

CBUHAN 12.95-1

Upgrade the ETP software on the Active flash of the ETP card using following MML command:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0-LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

After card restart, log-in to the card using following MML commands -ZDDS;ZRS:<physical address>switch_flash ctot

After the card comes up, upgrade the ETP software on the this new flash of the ETP card using following MMLcommand:ZWDL:UT=<ETP_type>,UI=0,SERVER=<ip address>,SW=W0- LFILES/<GGNET*_file>,MODE=ACTIVE;

Note: For FTP server IP address, check MCMU ETPSIG-I IP address. Image file is GGNETPAB.IMG forETP(A).

Restart the ETP card. Note that after this point, the upgraded software will be running on ETP card.ZUSU:UT=<ETP type>,UI=<index>;

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

To restore to the original default flash, we need to switch flash again. So as the ETP card comes up, log-in to thecard using following MML commands -ZDDSZRS:<physical address>Switch to other flash using below command ST command -switch_flash ctot

NOTE: This command will switch flash and restart the ETP card as well. After the card comes up, open anew MML session.

Verify that the new software version has been upgraded on active flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=ACTIVE;

Verify that the new software version has been upgraded on standby flash using following command :ZWDM:UT=<ETP_ type>,UI=<index>,MODE=STANDBY;

Page 238: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

238 (270)

14.1.6 Diagnostic

Run diagnostic to the ETPAZUDU:ETPA,<unit_index>;

Note: The diagnostic part will be run on both MCMUs.

Change working state of ETPA to WO-EXZUSC:ETPA,<unit index>,:WO;

Note:-Create the MSS/MGW configurations.Feature 1753 can be turned ON with the below command onceMSS/MGW configurations are completed.

- ZW7M: FEA=1753:ON; (Ao IP, TC in MGW)

Page 239: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

239 (270)

15 COPY THE HW EQUIPMENT DATABASE INFORMATION TO THE DISK (DBC)

ZDBC:EQUIPM,0;

Page 240: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

240 (270)

16 ACTIONS AFTER UPGRADE & POST CONDITIONS

16.1 BSS Integration

After ETP/ETPA equipment upgrade in BSCs, make BSC integration for upgraded units according BSSintegration. The document can be found from NED.

16.2 BSC configuration printout (post-check)

The information about the BSC configurations and conditions are collected.The checking can be made by using the macro (UPGMAIN.HIT) or manually following the instructions from “BSCconfiguration printout”-document delivered in Release Binder.

16.3 Return to the old HW configuration

If return to old HW configuration is needed, follow the instructions in this document in the reverse order. Oractivate fallback build taken before HW upgrade and change cablings according the Cablings instructions forBSC3i which can be found from NED.

Page 241: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

241 (270)

17 APPENDIX :

17.1 Appendix 1: SW 256B Dip switch settings

17.1.1 SW256B jumper settings

17.1.2 PCM mode settings (SW1)

The PCM mode set up is made with micro switches:- 4M/8M mode for serial buses R0...R31, T0...T31- 4M/8M mode for serial buses R32...R63, T32...T63

17.1.2.1 BSC part is BSC3i 1000/2000

Table: PCM mode settings on the SW256B (SW1).

SW1 SwitchSlot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B 0 1 OFF OFF OFF OFF PCM 0-255 4M mode selected

SW256B 1 2 OFF OFF OFF OFF PCM 256-511 4M mode selected

SW256B 2 3 ON ON OFF OFF PCM 512-767 8M mode selected

SW256B 3 4 ON ON OFF OFF PCM 768-1023 8M mode selected

SW256B 4 5 OFF OFF OFF OFF PCM 1024-1279 4M mode selected

SW256B 5 6 ON ON OFF OFF PCM 1280-1535 8M mode selected

SW256B 6 7 ON ON OFF OFF PCM 1536-1791 8M mode selected

SW256B 7 8 ON ON OFF OFF PCM 1792-2047 8M mode selected

17.1.2.2 BSC part is Upgraded Flexi

Table: PCM mode settings on the SW256B (SW1).

Page 242: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

242 (270)

SW1 SwitchSlot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B0

1 OFF OFF OFF OFF PCM 0-255 4M mode selected

SW256B1

2 OFF OFF OFF OFF PCM 256-511 4M modeselected

SW256B2

3 ON ON OFF OFF PCM 512-767 8M modeselected

SW256B3

4 ON ON OFF OFF PCM 768-1023 8M modeselected

SW256B4

5 ON ON OFF OFF PCM 1024-1279 4M modeselected

SW256B5

6 ON ON OFF OFF PCM 1280-1535 8M modeselected

SW256B6

7 ON ON OFF OFF PCM 1536-1791 8M modeselected

SW256B7

8 ON ON OFF OFF PCM 1792-2047 8M modeselected

17.1.3 Interchangeability code settings (SW2)

The setting of the interchangeability code (ICC code) is presented in the table below.

Table: Interchangeability settings on the SW256B (SW2).Switch Default setting Function1-8 OFF Interchangeability code bit 32-7 OFF Interchangeability code bit 23-6 OFF Interchangeability code bit 14-5 OFF Interchangeability code bit 0

The table below presents the setting of the interchangeability code.Table: Interchangeability code (ICC) settings (SW2).

ICC code Switch settingSwitch 1 Switch 2 Switch 3 Switch 4

A OFF OFF OFF OFFB OFF OFF OFF ONC OFF OFF ON OFFD OFF OFF ON ONE OFF ON OFF OFFF OFF ON OFF ONG OFF ON ON OFFH OFF ON ON ONJ ON OFF OFF OFFK ON OFF OFF ONL ON OFF ON OFFM ON OFF ON ONN ON ON OFF OFFP ON ON OFF ON

Page 243: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

243 (270)

ICC code Switch settingR ON ON ON OFF

The first interchangeability code A corresponds to all switches OFF, after which the settings start to roll for eachinterchangeability code change.

17.1.4 Serial Broadband SB1 settings (SW3)

The setting of the Serial Broadband Interface capacity is presented in the table below.

17.1.4.1 BSC part is BSC3i 1000/2000

Table: Serial Broadband Interface SB1 settings on the SW256B (SW3).

SW3 SwitchSlot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B 0 1 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 1 2 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 2 3 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 3 4 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 4 5 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 5 6 ON ON OFF OFF SB1 interface isdisabled

SW256B 6 7 ON ON OFF OFF SB1 interface isdisabled

SW256B 7 8 OFF OFF ON *) OFF SB1 interface, PCMcircuits 1792-1855connected.A. Selected if SB3interface of ETPE/T intrack 6 of GTIC-0 (forBSC3i 1000).Selected if SB3interface of ETPE/T intrack 1 of ETC-5 (forBSC3i 2000)connected.B. Selected if SB3interface of ETPE/T intrack 6 GTIC 0/GTIC 1connected.

*) If ETPE or ETPT is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.

17.1.4.2 BSC part is Upgraded Flexi Single/Double cabinet

SW3 SwitchSlot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B 0 1 OFF OFF OFF OFF SB1 interface isdisabled

Page 244: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

244 (270)

SW256B 1 2 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 2 3 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 3 4 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 4 5 OFF OFF OFF OFF SB1 interface isdisabled

SW256B 5 6 ON OFF ON*) OFF SB1 interface, PCMcircuits 1280-1343connected.A. Selected if SB1interfaces of ETP(A)in track 2 of GTIC-2(only for Singlecabinet) connected.

SW256B 6 7 ON OFF OFF OFF SB1 interface, PCMcircuits 1536-1599connected.A. Selected if SB1interfaces of ETP(A)in track 2 of GTIC-3 (only or Single cabinet)connected.

SW256B 7 8 OFF OFF ON *) OFF SB1 interface, PCMcircuits 1792-1855connected.A. Selected if SB3interfaces of ETPE/Tin track 6 of GTIC-0(for Single cabinet).Selected if SB3interfaces of ETPE/Tin track 1 of ETC-5(for Double cabinet).B. Selected if SB3interface of ETPE/T intrack 6 GTIC 0/GTIC 1connected.

*) If ETPE or ETPTor ETP(A) is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.C.Pool redundancy in use.

17.1.5 Serial Broadband SB2 settings (SW4)

17.1.5.1 BSC part is BSC3i 1000/2000

Table: Serial Broadband Interface SB1 settings on the SW256B (SW4).

SW4 Switch

Slot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

Page 245: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

245 (270)

SW256B 0 1 OFF OFF ON*) OFF

SB2 interface, PCM circuits64-127 connected.A. Selected if SB2interfaces of ETPE/T intrack 1 of ETC-4 (for BSC3i2000).B. Selected if SB2 interfaceof ETPE/T in track 1 ofETC-4/ETC-5 (for BSC3i2000) connected.

SW256B 1 2 OFF OFF ON*) OFF

SB2 interface, PCM circuits320-383 connected.A. Selected if SB2interfaces of ETPE/T intrack 1 of GTIC-0 (for BSC3i1000). Selected if SB2interfaces of ETPE/T intrack 6 of ETC-3 (for BSC3i2000).B. Selected if SB2interfaces of ETPE/T intrack 1 GTIC 1/GTIC 0.C. Selected if SB2 interfaceof ETP(A) in track 3 of ETC-4 (for BSC3i 2000)connected.

SW256B 2 3 OFF OFF OFF OFF SB2 interface is disabled.

SW256B 3 4 OFF OFF OFF OFF SB2 interface is disabled.

SW256B 4 5 OFF OFF ON*) OFF

SB2 interface, PCM circuits1088-1151 connected.A. Selected if SB2interfaces of ETPE/T intrack 6 of ETC-4 (for BSC3i2000) connected.B. Selected if SB2 interfaceof ETPE/T in track 6 ofETC4/ETC 5 connected.C. Selected if SB2 interfaceof ETP(A) in track 3 ofGTIC-0 (for BSC3i 1000)connected. Selected if SB2interface of ETP(A) in track3 of ETC-2 (for BSC3i 2000)connected.

SW256B 5 6 OFF OFF ON*) OFF

SB2 interface, PCM circuits1344-1407 connected.A. Selected if SB3interfaces of ETPE/T intrack 6 of ETC-5 (for BSC3i2000).B. Selected if SB3 interfaceof ETPE/T in track 1 ofETC2/ETC3 connected.

Page 246: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

246 (270)

SW256B 6 7 OFF OFF ON*) OFF

SB2 interface, PCM circuits1600-1663 connected.A. Selected if SB2interfaces of ETPE/T intrack 6 of ETC-5 (for BSC3i2000).B. Selected if SB2 interfaceof ETPE/T in track 1 of ETC2/ETC3 connected.

SW256B 7 8 OFF OFF ON*) OFF

SB2 interface, PCM circuits1856-1919 connected.A. Selected if SB2interfaces of ETPE/T intrack 6 of GTIC-0 (for BSC3i1000) or selected if SB2interfaces of ETPE/T intrack 1 of ETC-5 (for BSC3i2000).B. Selected if SB2 interfaceof ETPE/T in track 6 ofGTIC 0/GTIC 1 connected.

*) If ETPE or ETPT or ETP(A)is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.C. Pool redundancy in use.

17.1.5.2 BSC part is Upgraded Flexi

SW4 Switch

Slot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B 0 1 OFF OFF ON*) OFF

SB2 interface, PCM circuits64-127 connected.A. Selected if SB2interfaces of ETPE/T intrack 1 of ETC-4(for Doublecabinet).B. Selected if SB2 interfaceof ETPE/T in track 1 ofETC-4/ETC-5 connected.

SW256B 1 2 OFF OFF ON*) OFF

SB2 interface, PCM circuits320-383 connected.A. Selected if SB2interfaces of ETPE/T intrack 1 of GTIC-0(for Singlecabinet).Selected if SB2interfaces of ETPE/T intrack 6 of ETC-3 (for Doublecabinet).B. Selected if SB2interfaces of ETPE/T intrack 1 GTIC 1/GTIC 0.C. Selected if SB2interfaces of ETP(A) in track3 of ETC-4 (for doublecabinet) connected.

SW256B 2 3 OFF OFF OFF OFF SB2 interface is disabled

Page 247: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

247 (270)

SW256B 3 4 OFF OFF OFF OFF SB2 interface is disabled

SW256B 4 5 OFF OFF ON*) OFF

SB2 interface, PCM circuits1088-1151 connected.A. Selected if SB2interfaces of ETPE/T intrack 6 of ETC-4(for Doublecabinet).B. Selected if SB2 interfaceof ETPE/T in track 6 ofETC4/ETC 5 connected.C. Selected if SB2interfaces of ETP(A) inGTIC-0(for single cabinet)connected. Selected if SB2interface of ETP(A) in ETC-2 (for Double cabinet).

SW256B 5 6 OFF OFF ON*) OFF

SB2 interface, PCM circuits1344-1407 connected.A. Selected if SB3interfaces of ETPE/T intrack 6 of ETC-5(for Doublecabinet).B. Selected if SB3 interfaceof ETPE/T in track 1 ofETC2/ETC3 connected.

SW256B 6 7 OFF OFF ON*) OFF

SB2 interface, PCM circuits1600-1663 connected.A. Selected if SB2interfaces of ETPE/T intrack 6 of ETC-5 (for Doublecabinet).B. Selected if SB2 interfaceof ETPE/T in track 1 of ETC2/ETC3 connected.

SW256B 7 8 OFF OFF ON*) OFF

SB2 interface, PCM circuits1856-1919 connected.A. Selected if SB3interfaces of ETPE/T intrack 6 of GTIC-0(for Singlecabinet).Selected if SB3interfaces of ETPE/T intrack 1 of ETC-5 (for Doublecabinet ).B. Selected if SB2 interfaceof ETPE/T in track 6 ofGTIC 0/GTIC 1 connected.

*) If ETPE or ETPT or ETP(A) is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.C. Pool redundancy in use.

17.1.6 Serial Broadband SB3 settings (SW5)

The setting of the Serial Broadband Interface capacity is presented in the table below.

17.1.6.1 BSC part is BSC3i 1000/2000

Page 248: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

248 (270)

Table: Serial Broadband Interface SB3 settings on the SW256B (SW5).

SW5 Switch

Slot 1 (1-8) 2 (2-7) 3 (3-6)

4(4-5) Note!

SW256B 0 1 OFF OFF OFF OFF SB3 interface is disabled.

SW256B 1 2 OFF OFF OFF OFF SB3 interface is disabled.

SW256B 2 3 OFF OFF OFF OFF SB3 interface is disabled.

SW256B 3 4 OFF OFF OFF OFF SB3 interface is disabled.SW256B 4 5 OFF OFF OFF OFF SB3 interface is disabled.

SW256B 5 6 OFF OFF OFF OFF SB3 interface is disabled.

SW256B 6 7 OFF OFF ON *) OFF

SB3 interface, PCM circuits 1664-1727connected.A. Selected if SB2 interfaces of ETPE/T in track 6of ETC-2 (for BSC3i 2000).B. Selected if SB2 interface of ETPE/T in track 6ETC-2/ETC-3 connected (for BSC3i 2000).

SW256B 7 8 OFF OFF OFF OFF SB3 interface is disabled.

*) If ETPE or ETPT is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.

17.1.6.2 BSC part is Upgraded Flexi

Table: Serial Broadband Interface SB3 settings on the SW256B (SW5).

SW5 Switch

Slot

1(1-8)

2 (2-7)

3 (3-6)

4(4-5) Note!

SW256B0 1 OFF OFF OFF OFF SB3 interface is disabledSW256B1 2 OFF OFF OFF OFF SB3 interface is disabledSW256B2 3 OFF OFF OFF OFF SB3 interface is disabledSW256B3 4 OFF OFF OFF OFF SB3 interface is disabled

SW256B4 5 OFF OFF

ON*) OFF

SB3 interface, PCM circuits 1088-1151connected.A. Selected if SB2 interfaces of ETPE/T in track 6of ETC-4(for Double cabinet).B. Selected if SB2 interface of ETPE/T in track 6of ETC4/ETC 5 connected.

SW256B5 6 OFF OFF

ON*) OFF SB3 interface is disabled

SW256B6 7 OFF OFF

ON*) OFF

SB3 interface, PCM circuits 1664-1727connected.A. Selected if SB2 interfaces of ETPE/T in track 6of ETC-2(for Single cabinet).B. Selected if SB2 interface of ETPE/T in track 6ETC-2/ETC-3 connected.

SW256B 8 OFF OFF OFF OFF SB3 interface is disabled

Page 249: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

249 (270)

7

*) If ETPE or ETPT is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.

17.1.7 Serial Broadband SB4 settings (SW6)

The setting of the Serial Broadband Interface capacity is presented in the table below.

17.1.7.1 BSC part is BSC3i 1000/2000

Table: Serial Broadband Interface SB4 settings on the SW256B (SW6).

SW6 Switch

Slot 1 (1-8) 2 (2-7) 3 (3-6) 4 (4-5) Note!

SW256B 0 1 OFF OFF ON *) OFF

SB4 interface, PCM circuits 192-255 connected.A. Selected if SB3 interfaces of ETPE/T in track 1 ofETC-4 (for BSC3i 2000).B. Selected if SB3 interface of ETPE/T in track 1 ofETC5/ETC4 connected (for BSC3i 2000).

SW256B 1 2 OFF OFF ON *) OFF

SB4 interface, PCM circuits 448-511 connected.A. Selected if SB3 interfaces of ETPE/T in track 1ofGTIC-0 (for BSC3i1000). Selected if SB3 interfaces ofETPE/T in track 6 of ETC-3 (for BSC3i 2000).B. Selected if SB3 interface of ETPE/T in track 1 GTIC0/GTIC 1 connected.C. Selected if SB2 interface of ETP(A) in track 3 ofETC-5 (for BSC3i 2000) connected.

SW256B 2 3 OFF OFF OFF OFF SB4 interface is disabled.

SW256B 3 4 OFF OFF OFF OFF SB4 interface is disabled.

SW256B 4 5 OFF OFF ON *) OFF

SB4 interface, PCM circuits 1216-1279 connected.A. Selected if SB3 interfaces of ETPE/T in track 6 ofETC-4 (for BSC3i 2000).B. Selected if SB3 interface of ETPE/T in track 6 ofETC4/ETC5 connected (for BSC3i 2000).C. Selected if SB2 interface of ETP(A) in track 3 ofGTIC-1 (for BSC3i 1000) connected or selected if SB2interface of ETP(A) in track 3 of ETC-3 (for BSC3i2000) connected.

SW256B 5 6 OFF OFF OFF OFF SB4 interface is disabled.

SW256B 6 7 OFF OFF ON *) OFF

SB4 interface, PCM circuits 1728-1791 connected.A. Selected if SB3 interfaces of ETPE/T in track 6 ofETC-2 (for BSC3i 2000).B. Selected if SB3 interfaces of ETPE/T in track 6 ofETC 2/ETC 3 connected (for BSC3i 2000).

SW256B 7 8 OFF OFF OFF OFF SB4 interface is disabled.

*) If ETPE or ETPT or ETP(A) is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.C. Pool redundancy in use.

Page 250: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

250 (270)

17.1.7.2 BSC part is Upgraded flexi

Table: Serial Broadband Interface SB4 settings on the SW256B (SW6).

SW6 Switch

Slot1 (1-8)

2 (2-7)

3 (3-6)

4(4-5) Note!

SW256B0 1 OFF OFF ON *) OFF

SB4 interface, PCM circuits 192-255 connected.A. Selected if SB3 interfaces of ETPE/T in track 1 ofETC-4(for Double cabinet).B. Selected if SB3 interface of ETPE/T in track 1 ofETC5/ETC4 connected.

SW256B1 2 OFF OFF ON *) OFF

SB4 interface, PCM circuits 448-511 connected.A. Selected if SB3 interfaces of ETPT in track 1ofGTIC-0(for Single cabinet).Selected if SB3 interfacesof ETPT in track 6 of ETC-3 (for Double cabinet).B.Selected if SB3 interface of ETPT in track 1 GTIC0/GTIC 1 connected.C.Selected if SB3 interfaces of ETP(A) in track3 ofETC-5 (for double cabinet) connected.

SW256B2 3 OFF OFF OFF OFF SB4 interface is disabledSW256B3 4 OFF OFF OFF OFF SB4 interface is disabled

SW256B4 5 OFF OFF ON *) OFF

SB4 interface, PCM circuits 1216-1279 connected.A. Selected if SB3 interfaces of ETPE/T in track 6 ofETC-4(for Double cabinet).B. Selected if SB3 interface of ETPE/T in track 6 ofETC4/ETC5 connected.C. Selected if SB3 interface of ETP(A) in track3 ofGTIC-1(for single cabinet) connected. Selected if SB3interface of ETP(A) in track3 of ETC-3(for Doublecabinet) connected.

SW256B5 6 OFF OFF OFF OFF SB4 interface is disabled

SW256B6 7 OFF OFF ON *) OFF

SB4 interface, PCM circuits 1728-1791 connected.A. Selected if SB3 interfaces of ETPE/T in track 6 ofETC-2(for Double cabinet).B. Selected if SB3 interfaces of ETPE/T in track 6 ofETC 2/ETC 3 connected

SW256B7 8 OFF OFF OFF OFF SB4 interface is disabled

*) If ETPE or ETPT or ETP(A) is not connected in this PCM position, switch must be OFFA. TXN redundancy is in use.B. HW redundancy in use.C. Pool redundancy in use.

17.2 Appendix 2: GTIC & ETC PCM usage in case of BSC3i 1000/2000

Note: ETP cards will occupy two tracks. PCMs in table are mentioned with primary track only.

Cartridg Typ Usage PIU Track 1 Trac Trac Trac Trac Track 6 Trac Trac

Page 251: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

251 (270)

e e type k 2 k 3 k 4 k 5 k 7 k 8

ETSI

GTIC-0

ANSI &ETSI ET16 904-919

920-935

936-951

952-967

968-983 984-999

864-879

880-895

GTIC-0ETSI

Transmissionredundancy

ETS2

64-126320-382

1088-1150

1408-1470

full capacity 192-254448-510

1216-1278

1472-1534

GTIC-0ETSI

Transmissionredundancy

ETS2448-510

1088-1150

1216-1278

1408-1470

1472-1534

halfcapacity 64-126

192-254

320-382

GTIC-0ETSI

HWredundancy ETS2

64-126320-382

1088-1150

1408-1470

1344-1406

1664-1726

1792-1854

1920-1982

192-254448-510

1216-1278

1472-1534

1600-1662

1728-1790

1856-1918

1984-2046

GTIC-0ETSI

Transmissionredundancy ETIP

64-126320-382

1088-1150

1408-1470

192-254448-510

1216-1278

1472-1534

GTIC-0ETSI

Transmissionredundancy

ETIP448-510

1088-1150

1216-1278

1408-1470

1472-1534

halfcapacity 64-126

192-254

320-382

GTIC-0ETSI

HWredundancy ETIP

64-126320-382

1088-1150

1408-1470

1344-1406

1664-1726

1792-1854

1920-1982

192-254448-510

1216-1278

1472-1534

1600-1662

1728-1790

1856-1918

1984-2046

GTIC-0ETSI

Transmissionredundancy

ETPE

320-383/448-511

1856-1919/1792-1855

HWredundancy

320-383/448-511

1856-1919/1792-1855

GTIC-0ETSI

Transmissionredundancy ETPT

320-383/448-511

1856-1919/1792-1855

HWredundancy ETPT

320-383/448-511

1856-1919/1792-1855

GTIC-0ETSI

Poolredundancy

ETP(A)

1088-

Page 252: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

252 (270)

1151

GTIC-1

ANSI &ETSI ET16

1408-1423

1424-1439

1440-1455

1456-1471

1472-1487

1488-1503

1504-1519

1520-1535

GTIC-1ETSI

Transmissionredundancy

ETS2

1344-1406

1664-1726

1792-1854

1920-1982

full capacity1600-1662

1728-1790

1856-1918

1984-2046

GTIC-1ETSI

Transmissionredundancy

ETS21344-1406

1664-1726

1792-1854

1856-1918

1920-1982

1984-2046

halfcapacity

1600-1662

1728-1790

GTIC-1ETSI

HWredundancy ETS2

64-126320-382

1088-1150

1408-1470

1344-1406

1664-1726

1792-1854

1920-1982

192-254448-510

1216-1278

1472-1534

1600-1662

1728-1790

1856-1918

1984-2046

GTIC-1ETSI

Transmissioredundancy ETIP

1344-1406

1664-1726

1792-1854

1920-1982

1600-1662

1728-1790

1856-1918

1984-2046

GTIC-1ETSI

Transmissioredundancy

ETIP1344-1406

1664-1726

1792-1854

1856-1918

1920-1982

1984-2046

halfcapacity

1600-1662

1728-1790

GTIC-1ETSI

HWredundancy ETIP

64-126320-382

1088-1150

1408-1470

1344-1406

1664-1726

1792-1854

1920-1982

192-254448-510

1216-1278

1472-1534

1600-1662

1728-1790

1856-1918

1984-2046

GTIC-1ETSI

Txnredundancy

ETPEHWredundancy

320-383/448-511

1856-1919/1792-1855

GTIC-1ETSI

Txnredundancy

ETPTHWredundancy

320-383/448-511

1856-1919/1792-1855

Page 253: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

253 (270)

GTIC-1ETSI

Poolredundancy

ETP(A)

1216-1279

ETC-0

ANSI &ETSI ET16 512-527

528-543

544-559

560-575

ETC-1

ANSI &ETSI ET16 576-591

592-607

608-623

624-639

ETC-2

ANSI &ETSI ET16

1344-1359

1360-1375

1376-1391

1392-1407

1600-1615

1616-1631

1632-1647

1648-1663

ETC-2ETSI

Txnredundancy

ETPE

1664-1727/1728-1791

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-2ETSI

Txnredundancy

ETPT

1664-1727/1728-1791

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-2ETSI

Poolredudancy

ETP(A)

1088-1151

ETC-3

ANSI &ETSI ET16

1664-1679

1680-1695

1696-1711

1712-1727

1728-1743

1744-1759

1760-1775

1776-1791

ETC-3ETSI

Txnredundancy

ETPE

320-383/448-511

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-3ETSI

Txnredundancy

ETPT

320-383/448-511

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-3ETSI

Poolredudancy

ETP(A)

1216-1279

ETC-4

ANSI &ETSI ET16

1920-1935

1936-1951

1952-1967

1968-1983

1984-1999

2000-2015

2016-2031

2032-2047

Page 254: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

254 (270)

ETC-4ETSI

Txnredundancy

ETPE

64-127/192-255

1088-1151/1216-1279

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-4ETSI

Txnredundancy

ETPT

64-127/192-255

1088-1151/1216-1279

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-4ETSI

Poolredudancy

ETP(A)

320-383

ETC-5

ANSI &ETSI ET16

1280-1295

1296-1311

904-919

920-935

936-951 952-967

968-983

984-999

ETC-5ETSI

Txnredundancy

ETPE

1856-1919/1792-1855

1600-1663/1344-1407

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-5ETSI

Txnredundancy

ETPT

1856-1919/1792-1855

1600-1663/1344-1407

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-5ETSI

Poolredudancy

ETP(A)

448-511

ANSI

GTIC-0

ANSI&ETSI ET16

904-919

920-935

936-951

952-967

968-983

984-999

864-879

880-895

GTIC-0 ANSI

Transmissioredundancy

ETS2

2048-2131

2216-2299

2384-2467

2552-2635

full capacity2132-2215

2300-2383

2468-2551

2636-2719

GTIC-0 ANSI

Transmissioredundancy

ETS2halfcapacity

2048-2131

2132-2215

2216-2299

2300-2383

2384-2467

2468-2551

2552-2635

2636-2719

Page 255: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

255 (270)

GTIC-0 ANSIHWredundancy ETS2

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-0 ANSITransmissioredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2132-2215

2300-2383

2468-2551

2636-2719

GTIC-0 ANSI

Transmissioredundancy

ETIPhalfcapacity

2048-2131

2132-2215

2216-2299

2300-2383

2384-2467

2468-2551

2552-2635

2636-2719

GTIC-0 ANSIHWredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1

ANSI&ETSI ET16

1408-1423

1424-1439

1440-1455

1456-1471

1472-1487

1488-1503

1504-1519

1520-1535

GTIC-1 ANSI

Transmissioredundancy

ETS2

2720-2803

2888-2971

3056-3139

3224-3307

full capacity2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSI

Transmissioredundancy

ETS2halfcapacity

2720-2803

2804-2887

2888-2971

2972-3055

3056-3139

3140-3223

3224-3307

3308-3391

GTIC-1 ANSIHWredundancy ETS2

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSITransmissioredundancy ETIP

2720-2803

2888-2971

3056-3139

3224-3307

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSI

Transmissioredundancy

ETIPhalfcapacity

2720-2803

2804-2887

2888-2971

2972-3055

3056-3139

3140-3223

3224-3307

3308-3391

GTIC-1 ANSIHWredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

ETC-0

ANSI&ETSI ET16

512-527

528-543

544-559

560-575

Page 256: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

256 (270)

ETC-1

ANSI&ETSI ET16

576-591

592-607

608-623

624-639

ETC-2

ANSI&ETSI ET16

1344-1359

1360-1375

1376-1391

1392-1407

1600-1615

1616-1631

1632-1647

1648-1663

ETC-3

ANSI&ETSI ET16

1664-1679

1680-1695

1696-1711

1712-1727

1728-1743

1744-1759

1760-1775

1776-1791

ETC-4

ANSI&ETSI ET16

1920-1935

1936-1951

1952-1967

1968-1983

1984-1999

2000-2015

2016-2031

2032-2047

ETC-5

ANSI&ETSI ET16

1280-1295

1296-1311

904-919

920-935

936-951

952-967

968-983

984-999

17.3 Appendix 3: GTIC & ETC PCM usage in case of Upgraded Flexi

Cartridge Type UsagePIUtype Track 1

Track2

Track3

Track4

Track5 Track 6

Track7

Track8

ETSI

GTIC-0

ANSI&ETSI ET16 904-919

920-935

936-951

816-831

1072-1087 1328-1343

1792-1807

18081823

GTIC-0 ETSI

Transmissioredundancy

ETS2

64-126320-382

1088-1150

1408-1470

full capacity 192-254448-510

1216-1278

1472-1534

GTIC-0 ETSI

Transmissioredundancy

ETS2448-510

1088-1150 1216-1278

1408-1470

14721534

halfcapacity 64-126

192-254

320-382

GTIC-0 ETSIHWredundancy ETS2

64-126320-382

1088-1150

1408-1470

1344-1406 1664-1726

1792-1854

19201982

192-254448-510

1216-1278

1472-1534

1600-1662 1728-1790

1856-1918

19842046

GTIC-0 ETSITransmissioredundancy ETIP

64-126320-382

1088-1150

1408-1470

192-254448-510

1216-1278

1472-1534

GTIC-0 ETSI

Transmissioredundancy

ETIP448-510

1088-1150 1216-1278

1408-1470

14721534

halfcapacity 64-126

192-254

320-382

Page 257: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

257 (270)

GTIC-0 ETSIHWredundancy ETIP

64-126320-382

1088-1150

1408-1470

1344-1406 1664-1726

1792-1854

19201982

192-254448-510

1216-1278

1472-1534

1600-1662 1728-1790

1856-1918

19842046

GTIC-0 ETSI

Transmissioredundancy

ETPE

320-383/448-511

1856-1919/1792-1855

HWredundancy

320-383/448-511

1856-1919/1792-1855

GTIC-0 ETSI

Transmissioredundancy ETPT

320-383/448-511

1856-1919/1792-1855

HWredundancy ETPT

320-383/448-511

1856-1919/1792-1855

GTIC-0 ETSIPoolredundancy ETP(A)

1088-1151

GTIC-1

ANSI&ETSI ET16 1408-1423

1424-1439

1440-1455

1456-1471

1472-1487 1488-1503

1504-1519

15201535

GTIC-1 ETSI

Transmissioredundancy

ETS2

1344-14061664-1726

1792-1854

1920-1982

full capacity 1600-16621728-1790

1856-1918

1984-2046

GTIC-1 ETSI

Transmissioredundancy

ETS2 1344-14061664-1726

1792-1854 1856-1918

1920-1982

19842046

halfcapacity

1600-1662

1728-1790

GTIC-1 ETSIHWredundancy ETS2

64-126320-382

1088-1150

1408-1470

1344-1406 1664-1726

1792-1854

19201982

192-254448-510

1216-1278

1472-1534

1600-1662 1728-1790

1856-1918

19842046

GTIC-1 ETSITransmissioredundancy ETIP

1344-14061664-1726

1792-1854

1920-1982

1600-16621728-1790

1856-1918

1984-2046

GTIC-1 ETSI

Transmissioredundancy

ETIP 1344-14061664-1726

1792-1854 1856-1918

1920-1982

19842046

halfcapacity

1600-1662

1728-1790

GTIC-1 ETSIHWredundancy ETIP 64-126

320-382

1088-1150

1408-1470

1344-1406 1664-1726

1792-1854

19201982

Page 258: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

258 (270)

192-254448-510

1216-1278

1472-1534

1600-1662 1728-1790

1856-1918

19842046

GTIC-1 ETSI

Txnredundancy

ETPEHWredundancy

320-383/448-511

1856-1919/1792-1855

GTIC-1 ETSI

Txnredundancy

ETPTHWredundancy

320-383/448-511

1856-1919/1792-1855

GTIC-1 ETSIPoolredundancy ETP(A)

1216-1279

GTIC-2 ETSIPoolredundancy ETP(A)

1280-1343

GTIC-3 ETSIPoolredundancy ETP(A)

1536-1599

ETC-0

ANSI&ETSI ET16 512-527

528-543

544-559

560-575

ETC-1

ANSI&ETSI ET16 576-591

592-607

608-623

624-639

ETC-2

ANSI&ETSI ET16 1344-1359

1360-1375

1376-1391

1392-1407

1600-1615 1616-1631

1632-1647

16481663

ETC-2 ETSI

Txnredundancy

ETPE

1664-1727/1728-1791

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-2 ETSI

Txnredundancy

ETPT

1664-1727/1728-1791

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-2 ETSIPoolredundancy ETP(A)

1088-1151

ETC-3

ANSI&ETSI ET16 1664-1679

1680-1695

1696-1711

1712-1727

1728-1743 1744-1759

1760-1775

17761791

Page 259: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

259 (270)

ETC-3 ETSI

Txnredundancy

ETPE

320-383/448-511

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-3 ETSI

Txnredundancy

ETPT

320-383/448-511

HWredundancy

1600-1663/1344-1407

1664-1727/1728-1791

ETC-3 ETSIPoolredundancy ETP(A)

1216-1279

ETC-4

ANSI&ETSI ET16 1920-1935

1936-1951

1952-1967

1968-1983

1984-1999 2000-2015

2016-2031

20322047

ETC-4 ETSI

Txnredundancy

ETPE

64-127/192-255

1088-1151/1216-1279

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-4 ETSI

Txnredundancy

ETPT

64-127/192-255

1088-1151/1216-1279

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-4 ETSIPoolredundancy ETP(A)

320-383

ETC-5

ANSI&ETSI ET16 1792-1807

1808-1823

904-919

920-935

936-951 816-831

1072-1087

13281343

ETC-5 ETSI

Txnredundancy

ETPE

1856-1919/1792-1855

1600-1663/1344-1407

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-5 ETSI

Txnredundancy

ETPT

1856-1919/1792-1855

1600-1663/1344-1407

HWredundancy

64-127/192-255

1088-1151/1216-1279

ETC-5 ETSIPoolredundancy ETP(A)

448-511

Page 260: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

260 (270)

Page 261: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

261 (270)

ANSI

GTIC-0

ANSI&ETSI ET16

904-919

920-935

936-951

816-831

1072-1087

1328-1343

1792-1807

1808-1823

GTIC-0 ANSI

Transmissioredundancy

ETS2

2048-2131

2216-2299

2384-2467

2552-2635

full capacity2132-2215

2300-2383

2468-2551

2636-2719

GTIC-0 ANSI

Transmissioredundancy

ETS2halfcapacity

2048-2131

2132-2215

2216-2299

2300-2383

2384-2467

2468-2551

2552-2635

2636-2719

GTIC-0 ANSI

HWredundancy ETS2

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-0 ANSI

Transmissioredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2132-2215

2300-2383

2468-2551

2636-2719

GTIC-0 ANSI

Transmissioredundancy

ETIPhalfcapacity

2048-2131

2132-2215

2216-2299

2300-2383

2384-2467

2468-2551

2552-2635

2636-2719

GTIC-0 ANSI

HWredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1

ANSI&ETSI ET16

1408-1423

1424-1439

1440-1455

1456-1471

1472-1487

1488-1503

1504-1519

1520-1535

GTIC-1 ANSI

Transmissioredundancy

ETS2

2720-2803

2888-2971

3056-3139

3224-3307

full capacity2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSI

Transmissioredundancy

ETS2halfcapacity

2720-2803

2804-2887

2888-2971

2972-3055

3056-3139

3140-3223

3224-3307

3308-3391

GTIC-1 ANSI

HWredundancy ETS2

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSI

Transmissioredundancy ETIP

2720-2803

2888-2971

3056-3139

3224-3307

Page 262: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

262 (270)

2804-2887

2972-3055

3140-3223

3308-3391

GTIC-1 ANSI

Transmissioredundancy

ETIPhalfcapacity

2720-2803

2804-2887

2888-2971

2972-3055

3056-3139

3140-3223

3224-3307

3308-3391

GTIC-1 ANSI

HWredundancy ETIP

2048-2131

2216-2299

2384-2467

2552-2635

2720-2803

2888-2971

3056-3139

3224-3307

2132-2215

2300-2383

2468-2551

2636-2719

2804-2887

2972-3055

3140-3223

3308-3391

ETC-0

ANSI&ETSI ET16

512-527

528-543

544-559

560-575

ETC-1

ANSI&ETSI ET16

576-591

592-607

608-623

624-639

ETC-2

ANSI&ETSI ET16

1344-1359

1360-1375

1376-1391

1392-1407

1600-1615

1616-1631

1632-1647

1648-1663

ETC-3

ANSI&ETSI ET16

1664-1679

1680-1695

1696-1711

1712-1727

1728-1743

1744-1759

1760-1775

1776-1791

ETC-4

ANSI&ETSI ET16

1920-1935

1936-1951

1952-1967

1968-1983

1984-1999

2000-2015

2016-2031

2032-2047

ETC-5

ANSI&ETSI ET16

1792-1807

1808-1823

904-919

920-935

936-951

816-831

1072-1087

1328-1343

Page 263: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

263 (270)

17.4 Appendix 4: Update ESBs with latest software

17.4.1 Update ESB Software

Make sure that the ESB-26-B/24-D cards has L3 supported software(4.6.7 or above)If not update the software via telnet or from BSC.

To update the software via BSC:

Check for the current version.ZYFM:ISW:SWU,<Unit index>:;

EXECUTION STARTEDUNIT UNIT SOFTWARE SWITCH OMU DISKTYPE INDEX NAME VERSION VERSION----------------------------------------------------SWU 0 ESB26 4.6.0 4.6-7

Update software from BSCZYFM:USW:SWU,<Unit Index>:;

Reboot the ESB-26 once software upload is completed. ZW6T:SWU,<Unit Index>:;

LOADING PROGRAM VERSION 5.15-0Telnet connection successfully opened to SWU 0 (ESB26), IP=10.0.0.18.Alma_Swu0>enAlma_Swu0#reload

Check for Software version after reloadZW6T:SWU,0:;

Telnet connection successfully opened to SWU 0 (ESB26), IP=10.0.0.18.Alma_Swu0>enAlma_Swu0#sh verN O K I ASwitch model : NOKIA ESB26SW version : 4.6.7 created Apr 14 2010 - 03:38:45Primary version : 4.6.7Secondary version : 4.6.5Java version : Java image not loadedLoader version : 1.1.7 created Oct 28 2004 - 13:38:38System Loader version : 4.6.7 created Apr 14 2010 - 03:34:16Up time : 1 days, 16 hours, 48 min, 7 sec.

17.4.2 Enabling or disabling the automatic loading of configuration filesThe parameter that sets whether automatic configuration file loading is allowed forcertain type of LAN switches may have been modified in the old build. This parametersetting is not updated during the network element upgrade. Therefore, you need to change the parametermanually after the software update.

1) Check the properties that are specific to the type of the LAN switch in the old build(YFM).ZYFM:IST;

2) Change the properties in the new build as needed (YFM).Depending on whether you want to enable or disable the automatic loading of the configurationfiles, select the relevant option below.

• Enable the automatic loading of the configuration file.ZYFM:ENA,<LAN switch type>;

• Disable the automatic loading of the configuration file.

Page 264: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

264 (270)

ZYFM:DIS,<LAN switch type>;

17.5 Appendix 5: ETP/STMU strapping settings.

17.5.1 ETP-A C111828

17.5.1.1 JumpersThere is following jumper pinheader:

Octeon control 6-pin pinheader (W1):

Place 1-6: Disable Octeon watchdog (jumper in place disables watchdog)Place 2-5: Baud rate 9600 and 115200 mode (jumper in place selects 115200)Place 3-6: Force Boot from FLASH 1

17.5.1.1.1 DIP SwitchesInterchangeability code settings

The interchangeability code setting is made with DIP-switch package S1.Use of this switch package is specified in. The switch package is located so that pin 1 is in the upper left cornerwhen the ETP-A unit is in the cartridge. The binary value of the switch is increased by one in everyinterchangeability change. The value 0000B (all switches OFF) of the switches corresponds to interchangeabilitycode A.

1234

8 7 6 5

OFF ON

SWITCH Defaultsetting

Function

1-8 OFF Interchangeability code bit 0 (LSB)

2-7 OFF Interchangeability code bit 1

3-6 OFF Interchangeability code bit 2

4-5 OFF Interchangeability code bit 3 (MSB)

Interchangeability code setting with DIP-switch S1

*) The first interchangeability code A corresponds to all switches OFF, after which the settings start to roll for eachinterchangeability code change.

The table below presents the setting of the interchangeability code.Code SW1: 4-5 SW1: 3-6 SW1: 2-7 SW1: 1-8

(MSB) (LSB)

Page 265: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

265 (270)

A OFF OFF OFF OFFB OFF OFF OFF ONC OFF OFF ON OFFD OFF OFF ON ONE OFF ON OFF OFFF OFF ON OFF ONG OFF ON ON OFFH OFF ON ON ONJ ON OFF OFF OFFK ON OFF OFF ONL ON OFF ON OFFM ON OFF ON ONN ON ON OFF OFFP ON ON OFF ONR ON ON ON OFF

Note: The use of letters I, O and Q as interchangeability codes is not allowed

On the rear of the backplane one ADMODxx is used to set the ETP-A usage (to notify where the ETP-A is used)according to the following table.

17.5.1.2 ADMODxxOn the rear of the backplane one ADMODxx is used to set the ETP-A usage (to notify where the ETP-A is used)according to the following table.

ETP-A used in ADMOD usedBSC3i ADMOD4

TCSM3i ADMOD5

CombinedBSC3i/TCSM3i

ADMOD6

17.5.2 ETP C111826

17.5.2.1 JumpersThere is following jumper pinheader:Octeon control 6-pin pinheader (W1):Place 1-6: Disable Octeon watchdog (jumper in place disables watchdog)Place 2-5: Baud rate 9600 and 115200 mode (jumper in place selects 115200)Place 3-6: Force Boot from FLASH 1

17.5.2.2 DIP SwitchesInterchangeability code settings

The interchangeability code setting is made with DIP-switch package S1.Use of this switch package is specified The switch package is located so that pin 1 is in the upper left corner whenthe ETP unit is in the cartridge. The binary value of the switch is increased by one in every interchangeabilitychange. The value 0000B (all switches OFF) of the switches corresponds to interchangeability code A.

Page 266: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

266 (270)

1234

8 7 6 5

OFF ON

SWITCH Defaultsetting

Function

1-8 OFF Interchangeability code bit 0 (LSB)

2-7 OFF Interchangeability code bit 1

3-6 OFF Interchangeability code bit 2

4-5 OFF Interchangeability code bit 3 (MSB)

*) The first interchangeability code A corresponds to all switches OFF, after which the settings start to roll for eachinterchangeability code change.

The table below presents the setting of the interchange ability code.Code SW1: 4-

5SW1: 3-6

SW1: 2-7

SW1: 1-8

(MSB) (LSB)A OFF OFF OFF OFFB OFF OFF OFF ONC OFF OFF ON OFFD OFF OFF ON ONE OFF ON OFF OFFF OFF ON OFF ONG OFF ON ON OFFH OFF ON ON ONJ ON OFF OFF OFFK ON OFF OFF ONL ON OFF ON OFFM ON OFF ON ONN ON ON OFF OFFP ON ON OFF ONR ON ON ON OFF

Note: The use of letters I, O and Q as interchangeability codes is not allowed.

17.5.2.3 ADMODxxOn the rear of the backplane one ADMODxx is used to set the ETP type (to notify the ANSI/ETSI environmentand the ETP variant) according to the following table.

ETP used ADMODused

ETSI ETPT ADMOD1

Page 267: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

267 (270)

ANSIETPT

ADMOD17

ETPE ADMOD0

17.5.3 ETS2

17.5.3.1 DIP Switches settings.

In addition to interchangeability code setting DIP-switch, the unit has another switch package S2. The use of thisswitch package is specified in Error! Reference source not found.. The switch package is located so that thepin 1 is in the upper left corner when the ETS2 unit is in the cartridge.

SWITCH Defaultsetting

Function

1-8 OFF Width of the HDLC link:

OFF = 16x64 kbit/s, ON = 8x64 kbit/s

2-7 OFF Reserved for future use

3-6 OFF IF#0 ETP mode:

OFF = normal mode, ON = ETP mode

4-5 OFF IF#1 ETP mode:

OFF = normal mode, ON = ETP mode

Configuration settings with DIP-switch S2 on ETS2

Page 268: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

268 (270)

17.6 Appendix 6: ETP username & password settings

Check ftp_authentication in first Flashcat /mnt/flash/common/ftp_auth.txt

Switch the flash using below commandswitch_flash

Check ftp_authentication in second Flashcat /mnt/flash/common/ftp_auth.txt

Switch the flash using below commandswitch_flash

Change_ftp_authenticationSyntaxchange_ftp_authentication <olduname> <oldpasswd> <newuname> <newpasswd>

Page 269: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

269 (270)

PurposeIt is used to reconfigure username and password of the FTP server remotely at ETP.

The current username,current password, new username and new password values are provided in the STcommand.

First the current username and current password of the FTP server is verified against the value stored in flashmemory. In case the information is correct, the new username and new password is saved in both the flashdevices.

In case the information does not match with that present in the flash unit,it just displays an error message.

Even if only one of the three values is to be changed, both the new username and password values are to beentered.

Parameter name DescriptionOlduname Current FTP server usernameOldpasswd Current FTP server passwordNewuname New FTP server usernameNewpasswd New FTP server password

Change_ftp_authentication parameter description.

Example:Example Scenario Command to be ExecutedTo reconfigure username and password of FTP server change_ftp_authentication <olduname> <oldpasswd>

<newuname> <newpasswd>

Sample Output Format:

ETPT/0/(ETPSIG M-PLANE IP ADDRESS)> change_ftp_authentication uname1 pass1 uname2 pass2------------------------------------------------------------------------------------------------------------------------> Command change_ftp_authentication executed on [7/8/2008 1:54:35:567605] <------------------------------------------------------------------------------------------------------------------------/*In case information is updated*/Updation Successful--------------------------------------------------------------------------------------------------------------------ETPT/0/(ETPSIG M-PLANE IP ADDRESS)>ETPT/0/(ETPSIG M-PLANE IP ADDRESS)> change_ftp_authentication uname1 pass1 uname2 pass2------------------------------------------------------------------------------------------------------------------------> Command change_ftp_authentication executed on [7/8/2008 1:54:35:567605] <------------------------------------------------------------------------------------------------------------------------/*In case information is incorrect*/ERROR: Information is not valid--------------------------------------------------------------------------------------------------------------------

Verify the ftp_authentication

Check ftp_authentication in first Flashcat /mnt/flash/common/ftp_auth.txt

Switch the flash using below commandswitch_flash

Check ftp_authentication in second Flashcat /mnt/flash/common/ftp_auth.txt

Switch the flash using below commandswitch_flash

Page 270: BSC Implementation for ETP_ETP-A_in BSC 3i 1000_2000_Upgraded Flexi_Ver1_14

DN09124914 BSC Implementation for ETP/ETP-A in BSC3i 1000/2000, Upgraded Flexi BSCCopyright 2013 Nokia Solutions and Networks. All rights reserved.CONFIDENTIALAPPROVED 1.14

270 (270)

Disclaimer

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Solutions and Networks customers only for the purposes of the agreement underwhich the document is submitted, and no part of it may be used, reproduced, modified ortransmitted in any form or means without the prior written permission of Nokia Solutions andNetworks. The documentation has been prepared to be used by professional and properlytrained personnel, and the customer assumes full responsibility when using it. Nokia Solutionsand Networks welcomes customer comments as part of the process of continuous developmentand improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity,or performance of the mentioned hardware or software products are given “as is” and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Solutions and Networks and the customer.However, Nokia Solutions and Networks has made all reasonable efforts to ensure that theinstructions contained in the document are adequate and free of material errors and omissions.Nokia Solutions and Networks will, if deemed necessary by Nokia Solutions and Networks,explain issues which may not be covered by the document.

Nokia Solutions and Networks will correct errors in this documentation as soon as possible. INNO EVENT WILL NOKIA SOLUTIONS AND NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT ORTHE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

NSN is a trademark of Nokia Solutions and Networks. Nokia is a registered trademark of NokiaCorporation. Other product names mentioned in this document may be trademarks of theirrespective owners, and they are mentioned for identification purposes only.

Copyright © 2013 Nokia Solutions and Networks. All rights reserved.