BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator....

48
BS-200 Network Camera Remote Surveillance with Security JAVA Base Web Page Providing Maximum Platform CompatibilityRemote Surveillance Via Internet or IntranetAutomatic Intruder Recording Via FTP or E-mail

Transcript of BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator....

Page 1: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

BS-200 Network Camera

Remote Surveillance with Security •JAVA Base Web Page Providing Maximum Platform Compatibility•

•Remote Surveillance Via Internet or Intranet• •Automatic Intruder Recording Via FTP or E-mail•

Page 2: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

Copyright Disclaimers The accuracy of contents in this manual has passed thorough checking and review before publishing. BOSER Technology Co., Ltd., the manufacturer and publisher, is not liable for any infringements of patents or other rights resulting from its use. The manufacturer will not be responsible for any direct, indirect, special, incidental or consequential damages arising from the use of this product or documentation, even if advised of the possibility of such damage(s). This manual is copyrighted and BOSER Technology Co., Ltd. reserves all documentation rights. Unauthorized reproduction, transmission, translation, and storage of any form and means (i.e., electronic, mechanical, photocopying, recording) of this document, in whole or partly, is prohibited, unless granted permission by BOSER Technology Co., Ltd. BOSER Technology Co., Ltd. reserves the right to change or improve the contents of this document without due notice. BOSER Technology Co., Ltd. assumes no responsibility for any errors or omissions that may appear in this manual, nor does it make any commitment to update the information contained herein.

TTTrrraaadddeeemmmaaarrrkkksss

BOSER is a registered trademark of BOSER Technology Co., Ltd. ISB is a registered trademark of BOSER Technology Co., Ltd. Intel is a registered trademark of Intel Corporation. Award is a registered trademark of Award Software, Inc. AMI is a registered trademark of AMI Software, Inc. All other trademarks, products and or product names mentioned herein are mentioned for identification purposes only, and may be trademarks and/or registered trademarks of their respective companies or owners.

© Copyright 2002 BOSER Technology Co., Ltd.

All Rights Reserved. Edition 1.0, September 24, 2002

Page 3: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

Table of Contents

Chapter 1 Introduction……………………………….1 1.1 Major Features....................................................................... 2

Chapter 2 Physical Connections……………………...3 2.1 Front Panel............................................................................. 3 2.2 Real Panel .............................................................................. 3

Chapter 3 Installation…………………………………5 3.1 BS-200 Installation Procedure ............................................. 5 3.2 Mount the BS-200 .................................................................. 5 3.3 Connector to Network........................................................... 5 3.4 Connect to Power Supply..................................................... 6 3.5 Assign IP Address................................................................. 6 3.6 Assign IP by IP Installer........................................................ 8

3.6.1 Execute IP Installer ........................................................................................9 3.6.2 Preparation before IP Assignment ........................................................9 3.6.3 Assign an IP Address to BOSER Video Server..................................10

3.7 Verify and Complete the Installation from Your Browser11 3.8 Focus Your Camera ............................................................ 11

Chapter 4 Network Camera Home Page……………13 4.1 Browsing Video Home Page .............................................. 13

Chapter 5 Configuration Page………………………14 5.1 Configuration Page ............................................................. 15 5.2 User Configuration.............................................................. 15

5.2.1 Append New User ..........................................................................................16 5.3 Server Configuration........................................................... 17 5.4 CCD Module Settings.......................................................... 19 5.5 Event Manager ..................................................................... 20 5.6 PTZ Adjustment................................................................... 22 5.7 Network Configuration ....................................................... 23 5.8 Motion Area Selection......................................................... 24 5.9 Clock Setting........................................................................ 25 5.10 Video Adjustment................................................................ 26 5.11 Serial Port Management ..................................................... 27 5.12 GPIO Status.......................................................................... 27 5.13 Miscellaneous Operation.................................................... 28

Page 4: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

Appendix A Upgrading The Software………………29 A.1 Check Software Version...........................................................................29 A.2 Obtain The Software (flash.bin)............................................................29 A.3 Upgrade Procedure Via FTP ....................................................................29

Appendix B Update Custom Web Pages……………33 B.1 Clean Up System...........................................................................................33 B.2 Download Complete Web Pages..........................................................33 B.3 Upload Custom Web Pages..................................................................... 34 B.4 Verify Updated Contents .......................................................................... 34 B.5 Save The Changes To Flash..................................................................... 34

Appendix C Emergency Facyory Default…………...37

Appendix D Trouble Shooting……………………….39

Appendix E Lenses Replacement……………………41

Page 5: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

Safety Instructions

Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions: Do not remove boards or integrated circuits from their anti-static

packaging until you are ready to install them. Before handling a board or integrated circuit, touch an unpainted portion

of the system unit chassis for a few seconds. This helps to discharge any static electricity on your body.

Wear a wrist-grounding strap, available from most electronic component stores, when handling boards and components. Fasten the ALLIGATOR clip of the strap to the end of the shielded wire lead from a grounded object. Please wear and connect the strap before handle the HS-6252 to ensure harmlessly discharge any static electricity through the strap.

Please use an anti-static pad when putting down any components or parts or tools outside the computer. You may also use an anti-static bag instead of the pad. Please inquire from your local supplier for additional assistance in finding the necessary anti-static gadgets.

NOTE: DO NOT TOUCH THE BOARD OR ANY OTHER SENSITIVE COMPONENTS WITHOUT ALL NECESSARY ANTI-STATIC PROTECTION.

Page 6: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

This page is intentionally left blank.

Page 7: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

1

Chapter 1 Introduction

BS-200 Network Camera is an Internet-based digital Network Camera with a built-in CCD module to distribute the compressed live video into Intranet/Internet through Ethernet connection.

BS-200 is a self-contained Web Server. Users could access the Network Camera only by browsing website over Internet using standard browser such as Explorer or Netscape and do all the management, configuration, and monitoring easily.

BS-200 contains an image compression chipset capable of delivering standard JPEG, MJPEG, and real-time video into limited network bandwidth.

Page 8: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

2

1.1 Major Features The BS-200 comes with the following features: Including CCD module, which provides all in one system for Internet

video application Self-Contained HTTP Web Server providing Internet capability IP assignment via ARP/Web Page easy to install for users JAVA-based web page providing maximum platform compatibility Active-X control for Internet Explorer providing maximum performance Motion Detection/Date/Time/GPIO Input for event trigger E-mail/FTP/Internal Buffer Storage/Relay Out for event action Programmable event script for various applications 3-layer User Security Control Remote Upgradeable firmware and user content pages via FTP Server operating control through CGI base script easy to integrate the

application for users One additional external video input and one internal video output Green power, fan needless, and hardware watchdog providing

robustness system in critical environment

Page 9: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

3

Chapter 2 Physical Connections

2.1 Front Panel

Built-on CCD Module, support AES/BLC/Day & Night control Built-in support of DC-Driver auto iris lens, level adjustment supported

2.2 Real Panel

Ethernet: Standard IEEE802.3 10 Based T port DC 12V: DC Power input, specification with 12V DC 1A PWR LED:

Power On: Constant red Emergency factory default: Blinking orange

Page 10: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

4

Network LED: Network Link (connected): Constant red Networks have activities: Blinking red Data sent out from server: Blinking green Network disconnected: Constant slow blinking green Upgrading software: Constant blinking orange from slow to fast

COM: DTE DSUB 9-pin male connector in BS-200, capable of connecting as a system console (default), or to external modem (optional).

Page 11: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

5

Chapter 3 Installation

3.1 Mount the BS-200 The BS-200 provides screw holes on both the top and bottom surfaces of the unit for mounting the stand assembly. You can mount your BS-200 on a desktop, a wall, or ceiling by adjusting the linked way of stand assembly.

3.2 Connector to Network Connect an Ethernet cable (twisted pair CAT5 terminated cable with a standard RJ-45 connector) to your BS-200 and attach it to the network.

Page 12: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

6

3.3 Connect to Power Supply Attach the external Power Adapter to the unit and connect it to your local power socket.

NOTE: Ensure you power supply adapter specification. The Output DC

12V 1A is for BS-200 Network Camera. The Input AC Voltage must match to your power system, e.g. 110V/220V.

3.4 Assign IP Address Before using BS-200, users must set the IP address in advance. There are two different ways to set IP address into BS-200. NOTE Before IP Assignment: Make sure the BS-200 is powered on and connected to the network

correctly.

Obtain a unique IP address from your network administrator.

Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits serial number labeled at the bottom side of BS-200

Following examples use PC with IP address 192.168.0.1, and going to setup BS-200 server to IP address 192.168.0.200 whose MAC address is 000429000150. DO NOT USE those addresses featured as examples in this document, always consult your network administrator before assigning an IP address.

The IP address assigned to BS-200 shall be the same IP domain (presented as same subnet mask) as PC IP address. In our case, PC IP address is 192.168.0.1 and BS-200 is 192.168.0.200, so the subnet mask shall be 255.255.255.0. If PC subnet mask is 255.255.255.128 or higher, then the domain can’t cover 192.168.0.200, so the setting won’t take effective.

Page 13: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

7

For speedily installing and easily setting the IP Address, the BOSER provides an IP Installer Wizard for you. Please install the application and see the user’s manual for detailed description and usage.

1. In Windows, open DOS window. Enter DOS by <Start Program MS-DOS Prompt>.

2. Ensure the IP address assigned to BS-200 doesn’t occupy by other Host. In DOS window, entering <ping 192.168.0.200> shall get “time out” message.

C:\>ping 192.168.0.200

Pinging 192.168.0.200 with 32 bytes of data:

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Ping statistBS-200 for 192.168.0.200:

Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),

Approximate round trip times in milli-seconds:

Minimum = 0ms, Maximum = 0ms, Average = 0ms

C:\>

3. Enter command <arp –s [BS-200 IP Address] [BS-200 MAC Address]>. In DOS, enter “arp –s 192.168.0.200 00-04-29-00-01-50”.

4. Enter command <ping –t [BS-200 IP Address]> shall get constant reply after 3~4 timeouts, then press CTRL-C to exit pinging. In DOS, enter “ping –t 192.168.0.200”.

C:\>arp –s 192.168.0.200 00-04-29-00-01-50

C:\>ping 192.168.0.200

Pinging 192.168.0.200 with 32 bytes of data:

Request timed out.

Request timed out.

Request timed out.

Page 14: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

8

Reply from 192.168.0.200: bytes=32 time=5ms TTL=255

Reply from 192.168.0.200: bytes=32 time=5ms TTL=255

Reply from 192.168.0.200: bytes=32 time=5ms TTL=255

Reply from 192.168.0.200: bytes=32 time=5ms TTL=255

Ping statistBS-200 for 192.168.0.200:

Packets: Sent = 7, Received = 4, Lost = 3 (42% loss),

Approximate round trip times in milli-seconds:

Minimum = 4ms, Maximum = 5ms, Average = 2ms

C:\>

5. Complete setting and verify the installation. Then, open your web browser (e.g. IE) and enter the IP address in the Location/Address field. Consequently, the BS-200 video home page will be opened. Enter http://192.168.0.200 in Location/Address field of IE, then the Internet live video can be opened.

3.5 Assign IP by IP Installer BOSER IP Installer is a Windows 98/ME/NT/2000 program. It is the software providing an easier way for the setting of IP address and network configurations of BOSER’s Network Camera and Internet Video Server. Using this tool, you can easily set multiple BOSER Network Cameras and Video Servers at the same time with the batch setting function. By utilizing IP Installer, the setting process is largely simplified and the setting time is effectively shortened. Moreover, IP installer can not only save all the configurations of Video Servers as backup, but also restore the previous configurations of Video Servers.

Page 15: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

9

3.5.1 Execute IP Installer 1. Double click the mouse left button on the IP Installer icon.

2. The BOSER IP Installer form is displayed on the screen.

3.5.2 Preparation before IP Assignment Always consult your network administrator before assigning an IP address to your server. Make sure the BOSER Video Servers is powered on and correctly connected to the network. Obtain an IP address not used yet from your network administrator. Each BOSER Network Video Servers has a unique Ethernet address (MAC address) shown on the bottom of the Video Server as the serial number (S/N) with 12 digitals (e.g. 000429-xxxxxx).

Page 16: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

10

3.5.3 Assign an IP Address to BOSER Video Server Select the MAC Address of your BOSER Video Server in the list. The MAC Address is identical to the unit’s S/N (Serial Number). And click the menu bar View/Property to open the Property Page for the selected item. After filling in the properties, click the OK button to submit the settings for the unit and the settings will be activated immediately.

Page 17: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

11

3.6 Verify and Complete the Installation from Your Browser

Start your browser and enter the IP Address of your BOSER Video Server in the location/address field.

3.7 Focus Your Camera Fix your preferred lens to the BOSER Video Server. Turning it clock wise fits the lens.

Page 18: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

12

This page is intentionally left blank.

Page 19: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

13

Chapter 4 Network Camera Home Page

4.1 Browsing Video Home Page Enter the URL (ex: http://192.168.0.200) in Location/Address field of IE and then Internet live video will be opened.

Video Size 1X, 2X, 4X Selection: Change video size for selected video

source. Where: NTSC Video PAL Video 1X: QCIF 176 horizontal by 112 vertical 176 horizontal by 144 vertical 2X: CIF 352 horizontal by 240 vertical 352 horizontal by 288 vertical 4X: FULL 704 horizontal by 480 vertical 704 horizontal by 576 vertical Snapshot: Take a picture from viewing video. Config: Click to Configuration pages of BOSER Network Camera

Page 20: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

14

This page is intentionally left blank.

Page 21: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

15

Chapter 5 Configuration Page

5.1 Configuration Page

5.2 User Configuration BOSER Network Camera provides 3-layer user security control as below:

Open for All: It is a factory default when no user enters in User configuration, it allows any user over Internet to monitor and configure the Network Camera.

Page 22: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

16

Restricted User: It is the user in User Configuration without administration permission. The user can be configured to have limited permission to see video, for example, “capable of changing video size, etc”.

Administrator User: It is the user in User Configuration with administration permission. The user has all permission to operate the Network Camera, such as managing, configuring, and upgrading the software.

5.2.1 Append New User

Name: New user name to login Password: Password for above user Confirm Password: Type again to confirm password Permission to: Indicate above user has any permission to:

Administration: If no, then user can’t enter administration page

Note: That the first user shall set and get administration privilege; otherwise, he can’t get into administration page any more. If this happened, he must use emergency factory default to clean all users.

Change Video Size: If no, only CIF size is allowed Submit: To add above new user into list Cancel: To abort above operation

Page 23: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

17

When entering “submit” at first time, Network Camera will ask for a new administrator to login in. Once getting users in list, then you could choose users in list to make modification (update), or remove specified user. Click “Save Changes” bottom if needed for existing data changed in Network Camera when power off.

5.3 Server Configuration Name: Specify server name Owner: Specify server owner Owner Email: If return mail address when using SMTP mail delivery is

not specified correctly, some security SMTP server may reject the delivery of this mail

MAC Address: Display MAC address information for this Network Camera. It’s read only

Firmware Version: Display firmware version information Language: Alternative language option. User may change the language

of web contents for different application Display Logo check box, File Name Field: Administrator may choose

to turn the BOSER Logo off, then a completely different home page displayed without BOSER Logo. Furthermore, administrator may put his own logo with his own file name to replace the BOSER Logo.

Live Video Using: You can select the ActiveX for better performance in MS IE, or select the Java Applet for more browsers comparability

Display Time check box: Display the time Stamp Display Text check Box: Display text block. Fill in the text string to

display

NOTE: The maximum display block area (Time + Text) are 12x4 characters. String length more than 12 will feed to next line, and totally 4 lines available. More than 4 lines will strip off

DHCP Settings: If there is a DHCP server installed on your LAN, you can enable DHCP to automatically obtain network settings such as IP address, subnet mask, default gateway, and DNS servers. Because the assigned IP address can be dynamically changed every time it obtains from the DHCP server, we provide a method called IP Notification to notify users that which IP address is acquired. IP Notification by FTP: If a FTP server is installed on your network,

you can enable this option to obtain the newly assigned IP address of your BOSER Network Camera. A HTML file named NewIP_xxxxxx.htm will appear under the upload path for you to link to BOSER Network Camera, where xxxxxx is the last six digits of the S/N.

Page 24: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

18

FTP Host Name: FTP server address Login Name: Name of your FTP account Password: Password used to log in your FTP account Upload Path: Path to put the file IP Notification by E-mail: With this option enabled, your BOSER

Network Camera will send E-mail to you as soon as it obtains the IP address from DHCP

SMTP Host Name: SMTP server Recipient: Your E-mail address From: Sender’s E-mail address Msg Subject: Subject of this E-mail

Click “Save Changes” bottom if needed for existing data changed in Network Camera when power off.

Page 25: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

19

5.4 CCD Module Settings NOTE: When using Lens with DC-Driver Auto IRIS capabilities, you must

set AES to “off” state in order to get optimal Lens performance.

Video Source: To select the video source from internal built-in CCD or

external camera Auto Electronic Shutter: The shutter will automatically adjust the

exposure of the built-in CCD to get the better illumination when set to on Back Light Compensation: Adjust the light balance method. When set

to “on”, it will be calculated by center area of video window. And when set to “off”, it will be calculated by full video window, which could compensate the light conditions if center object looks to dark

Day Night Control: Setting to “on”, it will switch to black/white mode when in low light (dark) condition automatically; setting to “off”, it will always display color video

Page 26: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

20

5.5 Event Manager Application developers wish to have different levels of customization within their own applications. They may build through event manager, the event system provides several trigger sources and action types which allow administrators to record the emergency images, such as Motion detection, IO control, FTP or E-mail to outside world. It’s easy to process – just fill and submit a simple form.

BOSER Network Camera’s event manager provides event control through programmable Event Scripts which are the combination of several events. Each event works simultaneously. If one of the trigger conditions in event script is satisfied, then corresponding action will start to execute accordingly. A comprehensive set of “trigger conditions” and “ action commands” allowed to fit in varies of applications without limitation. NOTE: The programmable event script has been supported since firmware

version 2.0. Please check out your currently firmware version from 5.3 Server Configuration.

Page 27: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

21

To start event manager, simply click below: Upper edit window, middle status box, lower message window, and bottom control icons mainly separate the event frame. There are two ways to enter the event script. One is to use “Script Wizard” which just follows the procedure to fill up some items. And, it will generate and append new script code to edit window. The other one is to edit the form manually, which is for experienced users that want to deeply control the functionalities of event operation. Event Script Edit: Text window to enter event script manually Event Status: Indicate the event status, “Stop Now” or “Start Now” Event Auto Start when Power On: The check box is to indicate whether

the current event will automatically start up or not when system boots up Message: A window to show the results when below command icon

pressed – normally will show “OK”, “Parsing”, “Fail”, or “Err String” which indicates the syntax error of parsing, and starts from the error position in the script

Save Script: Command to save and parse current scripts in the “Event Script Edit” window. If error, will be shown in the “Massage” window

Event Auto Start When Power On: The flag is to set the event script auto start-up when the system is power on

NOTE: Any changes in “Event Script Edit” window mush “Save Script” before “Start Script”; otherwise, the new changes will be lost and won’t take effective. Also the changes won’t be saved into permanent memory unless you click the “Save Changes” button in main Administration panel.

Clear: Command to clean up “Event Script Edit” window Start Script: Command to start the script execution Stop Script: Command to stop the script execution Script Wizard: Command to start the script wizard. It helps user to make

simple script automatically by wizard, but the wizard supports only partial trigger and action commands. To fully leverage the complete functionalities of event script, please refer to “Event Script Programmers Guide”

Set Motion Detection Area: In order to activate the motion detection, you must choose the detection area and start the motion detection script manually or by wizard.

Help: Script Help lists all the syntax of trigger and action command.

Page 28: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

22

5.6 PTZ Adjustment

Cam[n] type: To select the PTZ devices. BOSER Network Camera

support SONY D30, and LILIN Fast Dome Series, etc. Contact your distributor/dealer to get supporting model information of PTZ camera

Speed: To select the PTZ speed grade from 1 (slowest) to 10 (fastest) Preset Position/Name: There are 20 records of each individual sources,

user could put their favorite position with catchy name PTZ Panel: Control the PTZ devices Zoom in/out, Pan left/right, and Tilt

up/down.

Page 29: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

23

5.7 Network Configuration

IP Address: BOSER Network Camera IP address Subnet Mask: Subnet mask of your LAN. Note that the IP Address above

and Gateway IP Address below should be in the same subnet DNS IP Address: Domain name server information is to allow BOSER

Network Camera to contact external server with mnemonic domain name instead of numeric IP address

Gateway IP Address: BOSER Network Camera traffic to Internet should go through Gateway, if not setting this, only Intranet (LAN) can be accessed

HTTP Connection Port: Specify the HTTP web server listen port for client (browser) connection. Default uses port 80 (HTTP standard port), valid range from 0~65535

NOTE: Before changing the listen port, user must add a port directive “:” in browser URL in order to get correct connection. (i.e. http://<IP>:<Port>, e.g. http://192.168.0.200:8000 to access BOSER Network Camera with IP 192.168.0.200 and port with 8000). These features enable user to use BOSER Network Camera behind NAT or IP Sharing devices which could access up to 65536 BOSER Network Camera with one IP Address. The factory default won’t change the IP Address and Port setting. Once forgetting the specified port of your BOSER Network Camera, you must use ARP & Ping setting to restore the port setting back to 80.

Page 30: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

24

Click “Submit” bottom if needed, then BOSER Network Camera will automatically store the setting and reboot system (within 5 seconds to complete boot sequence) to take the setting effective.

5.8 Motion Area Selection

Motion Detection Region Selection: Move the mouse to the regions in

video window with white blocks to determine the motion trigger areas. After setting with clicking the left button of the mouse, the selected areas will be turned to red blocks

Page 31: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

25

5.9 Clock Setting

The built-in real-time clock of BOSER Network Camera provides accurate date/time of system even when power off. For different time zone or long period operation, you may need to adjust the clock – just enter Time and Date information then click Submit.

Click “Save Changes” bottom if needed for existing data changed in Network Camera when power off.

Page 32: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

26

5.10 Video Adjustment BOSER Network Camera is capable of detecting NTSC/PAL automatically, video signal active/lose, fully automatic (plug & see) and don’t need any user configuration.

Display Time Stamp & Text: To turn on bitmap over video just click on the

check box, and these bitmaps are defined in Server Setting paragraph Quality Adjustment: To adjust video contrast, brightness, hue, color

saturation, and quality. Note that the quality level affects compression ratio and file size of video

Page 33: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

27

Frame Delay: To set the delay time between frames. The unit of delay time is 10 microseconds. You can limit the output bandwidth via setting the frame delay to do the flow control of the video stream. When the value is set to 0, it means no limitation on the video stream

Click “Save Changes” bottom if needed for existing data changed in Network Camera when power off.

5.11 Serial Port Management Change the serial port mode and configure the serial port settings for the COM 2 (located in GPIO terminal block/Mini DIN).

5.12 GPIO Status Display the GPIO (General Purpose Input/Output) status. The GPIO Terminal Block/Mini DIN provides control signal input and output, which includes four GPIO inputs, one GPIO output as Relay function. Set The Relay: Click the radio button to set the relay to ON or OFF

Page 34: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

28

5.13 Miscellaneous Operation

Load Default: The Load Default retrieves all except network setting

NOTE: The factory default just recovers the working setting but it is saved to permanent memory (will back to previous setting after boot). To change the boot settings, you must set “Save Changes”).

Save Changes: Save the working setting to permanent memory that will retrieve after reboot

Reboot System: Force Network Camera to reboot Live Video: Redirect browser back to video home

page

Page 35: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

29

Appendix A Upgrading the Software

BOSER Network Camera is contained in Flash Memory, a silicon chip allowed to be erased and re-written. It provides an easy way to update the software without change any parts; just simply load the newest software from network.

The following procedures are to update the software:

A.1 Check Software Version Enter URL “http://IP Address>/ver” in your web browser, which will show you the software version.

Example: enter “http://192.168.0.200/ver” in IE3 URL location, you will see the software version – “Software Version=1.00 Revision 0905.1641”, which indicates the currently software version is 1.11. NOTE: You can also get the software version in configurations page on

Chapter 5.3 Server Configuration.

A.2 Obtain The Software (flash.bin) The latest version of the BOSER Network Camera software is free of charge from BOSER Technology Co., Ltd. or your local distributor.

A.3 Upgrade Procedure Via FTP 1. Download the newest software and unzip it into your local

Driver, for example “c:\temp”. Then, confirm the “flash.bin” file exists in this directory.

2. Remove all event setting and reset the BOSER Network Camera. You have two ways to remove the event lists. One is to choose” Event ID” and to use “Remove” icon on “Event” page. The other is to click the “Load Default” icon in configurations page to reset all settings; however, it will not only delete event lists, but also all other settings. Then click the “Reboot System” to restart the Network Camera or enter CGI command URL “http://<IP Address>/control?reboot=1” in your web browser.

Page 36: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

30

Caution: You must remove all event settings and reboot the network camera before doing the following procedures; otherwise, some occasional internal conflicts may endanger the Flash devices.

3. Start the FTP session and log in to the BOSER Network Camera. For example, in our case for Windows 98: Enter DOS by “Start Program MS-DOS Prompt” Change to the directory where the latest flash.bin exist Start FTP session by enter “ftp<IP Address>” Enter “root” as USERNAME, “pass” as PASSWORD, if no user in User List record. In case any user list exists, you will have to use your administrator’s USERNAME and PASSWORD to login

4. Set FTP to binary mode using the command “bin”. In FTP session window, enter “bin”

5. Upload the software into BOSER Network Camera by FPT “put” command. In FTP session window, enter “put flash.bin” In FTP session window, enter “bye” to quit FTP session

6. FTP session may freeze for around 1 minute to transfer and automatically upgrade the software. During that time, ping the BOSER Network Camera until get constant reply, which means system had completed upgrading and rebooting, then open browser to verify the software version been updated.

NOTE: If FTP session quits immediately after issued by command, you should continue pinging BOSER Network Camera instantly. If BOSER Network Camera replies to the ping command right after pinging, it means BOSER ICS may not enter the self-programming stage to verify the software version. If not updated, then you should reboot BOSER Network Camera and back to step 3 to try again.

C:\temp>ftp 192.168.0.200

Connected to 192.168.0.200.

220 192.168.0.200 BOSER FTP server (ARM_BE – V3.0H) ready.

User (192.168.0.200:(none)):root

331 Password required for root.

Password: <=enter pass as default

230 User root logged in.

ftp> bin

200 Type set to I. . . . More on next page . . .

Page 37: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

31

ftp> put flash.bin

200 PORT command successful.

150 Opening BINARY mode data connection for flash.bin

226 Transfer complete.

ftp: 2097152 bytes set in 10.11 Seconds 207.43Kbytes/sec.

ftp> bye

221 Goodbye. <=Quit ftp session immediately

<=if the window is frozen, please open another dos session

C:\temp>ping –t 192.168.0.200

Pinging 192.168.0.200 with 32 bytes of data:

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Request timed out.

Reply from 192.168.0.200: bytes =32 time=2ms TTL=255

Reply from 192.168.0.200: bytes =32 time=1ms TTL=255

Reply from 192.168.0.200: bytes =32 time<10ms TTL=255

Reply from 192.168.0.200: bytes =32 time<10ms TTL=255

Reply from 192.168.0.200: bytes =32 time<10ms TTL=255

Ping statistics for 192.168..200:

Packets: Sent = 13, Received = 5, Lost = 8 (61% loss),

Approximate round trip times in milliseconds:

Minimum = 0ms, Maximum = 2ms, Average = 0ms

Approximate round trip times in milliseconds: . . . More on next page . . .

Page 38: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

32

Minimum = 0ms, Maximum = 2ms, Average = 0ms

Control-C

C:\temp>

NOTE: Flash products can become damaged if the updating operation is not performed correctly. So please follow up above procedures carefully.

Page 39: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

33

Appendix B Update Custom Web Pages

BOSER Network Camera has a built-in web server, so the web contents are contained in Flash Memory, the same as software parts, allowed to erase and re-written. It provides an easy way to up date the web pages – just simply load and issue command from network (FTP and Telnet). Caution: The update of content page is very sensitive to system operation;

therefore, incorrect operation may cause system fail to response to any request. The following operations provided here are only for experienced system integrator. Remember that always consult to your distributor or dealer in advance to update the content.

The following procedures are to update the web page:

B.1 Clean Up System Before updating the pages, make BOSER Network Camera back to factory default stage – click “Load Default” button, click “Save Changes” button, and then click “Reboot System” button in configuration page. Keep BOSER Network Camera in an idle state, which stops all video requests from other station.

B.2 Download Complete Web Pages For backup purpose, we should download the complete built-in contents before updating. The pages layout is described as below: 3.0.0/WWW: Main video pages including static HTML and JAVA applet 3.0.0/WWW/Images: All graphical files 3.0.0/WWW/Admin: Administration pages when user clicks

“Configuration” in main video page 3.0.0/Sys: Video bitmap font file (Time Stamp and Text Bitmap) 3.0.0/Public: Internal message files

For convenience, some FTP utilities (e.g. Cute FTP, WSFTP) may be useful to download the complete page.

Page 40: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

34

NOTE: When user login, root directory is 3.0.0/. Do not change any file in 3.0.0/Sys, and 3.0.0/Public, because these files are only used internally

B.3 Upload Custom Web Pages You can use FTP utilities to upload the updated/added contents to their original directory. For example, if you wish to replace the BOSER banner logo with custom made “oem.jpg”. First, prepare your won “oem.jpg”, and then upload to 3.0.0/WWW/images. Finally, change the logo file name to oem.jpg in “Configuration Network Camera” page. NOTE: Any file upload to BOSER Network Camera should be set to

“binary” mode in FTP utility; otherwise, the file may be corrupted in BOSER Network Camera.

B.4 Verify Updated Contents After uploading the custom pages, open browser to verify the correctness of contents. If not correct, modify the pages and return to previous step to upload again.

B.5 Save The Changes To Flash Telnet to BOSER Network Camera and enter command “Up –w” to write the complete web pages into flash. The detailed procedures are list as below: Open DOS window Enter “telnet <IP Address>” Enter “root” and “pass” as username and password Enter “Up –w” to start the web content update program. The command is

case sensitive. Don’t enter the wrong case or you’ll get the command not find error message. After processing about 30 seconds, the BOSER Network Camera will restart automatically and complete the web content updating. Now you can open the browser to see the new web content

NOTE: The limitation of overall size of content pages is around 700K Bytes. Any file added/updated plus original downloaded file (~550K Bytes) should not exceed this size; otherwise, some files will be truncated or corrupted. If the corruption of any page happens, you will have to reload the original binary in order to recover the corruption.

Page 41: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

35

For example, the BOSER Network Camera IP address is 192.168.0.200, then: C:\temp>telnet 192.168.0.200

Page 42: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

36

This page is intentionally left blank.

Page 43: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

37

Appendix C Emergency Factory Default

In certain circumstance, to restore the server to initial factory default state may be necessary, normally processed through web page (Miscellaneous Operation). If the user can’t get into web page (e.g. Missing of Username and Password information), then he could use Emergency Factory Default to restore the factory default.

Procedures as below: 1. Turn the power off

2. Short the GPIO Terminal block pin 9 and pin 14 with small wire or switch

3. Turn the power on. When the Status LED starts to blink (orange), open the wire or switch that set GPIO Input 4 back to open immediately

4. Server will restore the factory default and restart

NOTE: When status LED starts to blink during power up, if not to set GPIO Input 4 back to open within 3 seconds, server will continue the boot sequence and doesn’t retrieve the factory default.

Page 44: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

38

This page is intentionally left blank.

Page 45: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

39

Appendix D Trouble Shooting

Symptoms Possible Causes Remedial Actions

The IP address is already used by another device

1. Disconnect your BOSER Network Camera from the network

2. Run the PING utility (as describedin PING Your IP Address, on Chapter 3.5 Assign IP Address by ARP) and follow the appropriate recommendations

NOTE: The assigned IP number can be assumed valid if the PING utility returns “request timed out” – in which case you should set the IP address again, power on the BOSER Network Camera and then try accessing the unit again

The BOSER Network Camera can not be accessed from a Web browser

The IP address is located within a different subnet

Run the PING utility (as described in PING Your IP Address, on Chapter 3.5 Assign IP Address by ARP). If the utility returns “no response” or similar, the diagnosis is probably correct. Then, you should proceed as follows: 1. Click “Start”, “Settings”, “Control

Panel” and “Network”

2. Specify the TCP/IP adapter and click on Properties. Then, click “IPAddress” in Properties

3. Check that the first 3 numbers within the IP address of your BOSER Network Camera matches the first 3 ones of your

. . . More on next page . . .

Page 46: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

40

Symptoms Possible Causes Remedial Actions

Workstation. If not, your BOSER Network Camera may be on a different subnet and the IP address cannot be set from this workstation. You must set the IP address for the BOSER Network Camera from a workstation on thesame subnet

In Windows 95, the ARP table was empty when you tried to set the IP address

In Windows 95, the ARP command can’t be used if your have an empty ARP table

Type “arp –a” to view the ARP table. If it is empty, you must ping an existing unit on your network before you can download the IP address on the BOSER Network Camera

The BOSER Network Camera can not be accessed from a Web browser

A programming script locks the unit

Restore the unit to the factory default settings

Page 47: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

41

Appendix E Lenses Replacement

The BOSER Network Camera supports any standard C/CS lens, including full DC-Iris lens. You can replace the built-in lens with any lens you like. Since the BOSER Network Camera is supplied with a CS-mount, any stand C or CS lens typically used in the surveillance industry can be used. Follow the instruct ions below to fit any C or CS type lens: 1. Use Normal Lenses

CS-mount lens mode is the standard type. When using C-mount lens, please use the CS-C conversion Ring.

2. Use the Zoom Lens (adjustment of the back focus)

The camera is set at the standard back focus position when shipped from factory. Depending on types of zoom lenses, however slight adjustment may be necessary. Adjust the lens back-focus by turning the focusing knob in either direction.

Place an object at any fixed distance and set the focus ring of the zoom lens to be used with

Set the zoom lens to fully TELE position and obtain the best focus position by turning the focus ring of the zoom

Then set the zoom lens to fully WIDE position and obtain the best focus position by turning the focusing knob

Repeat the procedures 2 and 3 until focus remains in constant among the zooming ranges

3. Use an Auto Iris Lens

When auto iris is used, connect the plug of the lens (for iris terminal) to the IRIS terminal at the side of camera

NOTE: If you use a DC-Iris lens, be sure to change the AES (Auto Electronic Shutter) to off mode. To do this change, please open the BOSER Network Camera Home Page and go to the Configuration page. Select the CCD module setting function to change the AES mode.

Page 48: BS-200 Version 1.0 September 2002 · Obtain a unique IP address from your network administrator. Each BS-200 has unique Ethernet address (MAC address), which is recorded as 12 digits

42

This page is intentionally left blank.