www.brusa.biz
CBX154�-�Dual Converter��BoxUltra-compact unit accommodated within a given volume
Features at a glance
• Resonant topology ensures very low switching losses and excellent EMC - behavior
• Very high effi ciency (up to 98 %)• Very high power density (>10 kW/l)• Patented Liquid Pin© cooling system for optimal
temperature behavior and performance• FPGA based very dynamic control loop
What makes it special�
• Bidirectional HV-battery converter and uni-directional fuel cell converter in one box
• The two converters may be controlled independently from each other
• Additional fused power distribution for up to four auxiliary devices (heating, air-conditioning,...)
Application example
BRUSA Elektronik AGNeudorf 14CH-9466 Sennwald+41 81 758 19 00 [email protected]
BRUSA Elektronik AGNeudorf 14CH-9466 Sennwald+41 81 758 19 00 [email protected] www.brusa.biz
BR
USA
/ 0
8.20
13 /
CB
X15
4
Dimensions
Specifi cations CBX154
High voltage battery converter CBX154Min. operating voltage 70 VDC
Max. operating voltage 350 VDC
Voltage range (full performance) 175 - 287 VDC
Continuous current / max. current 100 / 225 A
Effi ciency typical 98 %
Fuel cell converter CBX154Min. operating voltage 70 VDC
Max. operating voltage 350 VDC
Nominal voltage range 145 - 265 VDC
Continuous current / max. current 450 / 450 A
Effi ciency typical 98 %
DC link CBX154Min. operating voltage 330 VDC
Max. operating voltage 450 VDC
Nominal voltage range 380 - 410 VDC
Continuous current / max. current 250 / 315 A
Control circuit CBX154Voltage range for signals of control connector (AUX/clamp 30, Interlock, Enable/clamp 15) 9 - 16 V
Voltage signal range 0 - 500 V
Voltage signal accuracy (2V or 2% of measured value, whatever is bigger) +/- 2 V / %
Battery converter current signal range +/- 300 A
Fuel cell converter current signal range +/- 600 A
Current signal accuracy (2A or 2% of measured value, whatever is bigger) +/- 2 A / %
Switching frequency 48 kHz
Mechanical data / Cooling system CBX154Weight 26 kg
IP - protection IP6K7 ---
Ambient temperature range (operation) - 20 to + 85 °C
Coolant temperature range - 20 to + 65 °C
Coolant fl ow rate > 8 l / min
Pressure drop (@ 4 l/min, Tcoolant = 25°C) < 350 mbar