Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-30562

Table of contents

Planning Guide Purpose ........................................................................3

Vertical Platform Lift Definition ............................................................3

Benefits of Vertical Platform Lifts .........................................................3

Design Assistance ................................................................................3

General Information ............................................................................3

How it Works/Key Components ..........................................................4-5

Difference Between Enclosure and Hoistway/Shaftway ...........................5

Lift Height and Floor-to-Floor Measuring ...............................................6

Platforms ............................................................................................6

Platform Configurations .......................................................................7

Operating Controls ..............................................................................8

Options ......................................................................................... 9-10

Enclosure Doors and Gates ................................................................. 11

Site Construction Details .................................................................... 12

Application Specific Drawings ....................................................... 13-36

Landing Gate Detail ...................................................................... 37-40

Flush Mount Aluminum Door Detail ................................................ 41-45

Bruno VPL-3300B Series

Page 3: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

1-800-848-3056 | bruno.com/cvpl 3

Planning Guide Purpose

Use this planning guide to gain details on incorporating a Bruno Enclosure Vertical Platform Lift into a public building design. All Bruno commercial vertical platform lifts meet the following applicable codes and performance standards: • ASME A18.1-2011 Section 2 (Public) Safety Standards for Platform Lifts and Stairway Chairlifts • ASME A18.1-2014 Section 2 (Public) Safety Standards for Platform Lifts and Stairway Chairlifts • ASME A18.1-2017 Section 2 (Public) Safety Standards for Platform Lifts and Stairway Chairlifts • CAN/CSA B355-09 (Public) Lifts for Persons with Physical Disabilities • CAN/CSA B355-15 (Public) Lifts for Persons with Physical Disabilities • CSA B44.1-11/ASME A17.5-2011 - Elevator and Escalator Electrical Equipment • CSA B44.1-14/ASME A17.5-2014 - Elevator and Escalator Electrical Equipment • CSA - National Electric Code • NFPA 70 - National Electric Code

Vertical Platform Lift Definition

Vertical platform lifts (VPLs) are a cost-effective solution to make a church, school, office or other public building accessible for people using mobility devices. Sometimes called a wheelchair lift, a VPL provides code-compliant access up to 14’ in a variety of configurations (check with local jurisdiction) and are suitable for indoor or outdoor use.

Benefits of Vertical Platform Lifts

When providing access up to 14’ for a person in a wheelchair or other mobility device, code-compliant options include traditional elevators, ramps and vertical platform lifts. Vertical platform lifts can provide significant cost and space efficiencies.

Cost-EffectiveGain cost efficiencies by installing a vertical platform lift instead of an elevator or long ramp system.

CompactRamps require 12” horizontal travel for every 1” vertical travel. For example, a 36” rise would require a 36’ ramp. In addition to taking up significant space, ramps can be fatiguing. A vertical platform lift saves space and is automatically powered.

Meets USA ADA RequirementsVertical platform lifts are acknowledged in the Americans with Disabilities Act (ADA) Accessibility Guidelines as a means to provide public building access. Bruno VPLs are designed in accordance with ASME A18.1 section 2.

Design Assistance

Need help on specifying the right VPL configuration? Bruno’s commercial VPL support professionals can help design the right solution for your project. Email: [email protected]. Phone: 800.848.3056

General Information

FinishesBruno’s commercial VPL standard finish is electrostatically applied with a baked powder coat finish in champagne color. Platform and landing gate parts are E-coated for an extra level of protection from the outdoor elements.

Indoor / Outdoor All Bruno VPLs are suitable for indoor and outdoor applications. Optional cold-weather package recommended if operating temperature is below 20° F/-7°C.

Enclosure Vertical Platform Lift, access up to 14’

Page 4: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-30564

How It Works – Enclosure

Bruno’s Enclosure Vertical Platform lift is lightweight, easy to install and available in multiple configurations for access up to 14’. Enclosure VPLs are self-contained, so no additional construction of a hoistway or shaftway is needed. All Bruno Enclosure configurations include an ACME screw-driven system

with full-time battery operation, platform with side walls, and interlock door system. With full-size Plexiglas door and panel inserts, Bruno’s Enclosure VPL wheelchair lift is an attractive choice for ADA compliance. Bruno VPLs are Made-in-America.

Upper landing gate

Platform side wall

Grab rail (other side of platform wall)

Non-skid platform

Plexiglas panels

Fascia wall

Non-skid stationary ramp

Factory enclosure aluminum door with Plexiglas panels

Tower/Mast

Lighted platform controls w/AV alarm & emergency stop

Platform side wall

Enclosure key components

Page 5: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

1-800-848-3056 | bruno.com/cvpl 5

ACME Screw Drive System (image shown is a “tall” model)

Power requirements: 120VAC, 3A, single phase, 60 Hz

Manual lowering tool: An optional manual hand crank is offered to lower the device. The manual lowering hand-wheel has a black plastic handle and slotted shape that engages a square key on the main screw drive.

Emergency Battery Lowering System: standard on VPL models VPL-3310B, VPL-3312B, & VPL-3314B. In the event of a power failure, models VPL-3310B, VPL-3312B, and VPL-3314B have an external lockable keyed switch for lowering the platform by means of a separate battery located inside the electrical enclosure (control box).

Emergency Lowering Battery Backup Access Box Standard on tall VPLs only (Models VPL-3310B, VPL-3312B, and VPL-3314B)

Difference between Enclosure and Shaftway/Hoistway

EnclosureAll equipment is self-contained in an Enclosure VPL. All running clearances are built in, and it is constructed with an aluminum frame and Plexiglas side walls with a full-size Plexiglas door.

Shaftway/HoistwayThe vertical platform lift is placed inside a shaftway/hoistway built by others. The lift is hidden from sight behind two doors and equipment is placed inside the shaftway which is built to site drawings and meets running clearances of the lift.

Enclosure model Shaftway model

Tower/Mast cover

Belt drive

ACME Screw

Control box

Motor

Upper/lower limit switches

Travel carriage

Batteries

Page 6: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-30566

Lift Heights and Floor-to-Floor Measuring

Enclosure MeasuresModel Max Floor-to-Floor Min Floor-to-Floor Mast Height Unit Height Unit Weight

VPL-3353B 53” 11” 75-9/16” 95” 897 lb

VPL-3375B 75” 53” 97-9/16” 117” 970 lb

VPL-3310B 123” 75” 148-1/16” 165” 1210 lb

VPL-3312B 147” 75” 172-1/16” 189” 1304 lb

VPL-3314B 171” 75” 196-1/16” 213” 1400 lb

Platforms

The rated load for the platform is 750 lbs. Solid side platform walls measure 42” high. See below for typical platform features and components.

Platform Size Options: • 36” x 54” – standard • 36” x 48” • 36” x 60” • 42” x 60”

Lift height is defined as the distance from the lower landing where the lift will be placed to the upper landing. The lift can be installed with or without a pit. In a pit Installation, the measurement is from the bottom of the pit to the upper landing. For a floor installation, the measurement is from the floor to the upper landing.

Model selection is determined by floor-to-floor lift height, a critical measurement in designing a vertical platform lift. See below for a table to select the appropriate model based on lift height.

42” high sidewalls

Bottom platform safety panel

Non-skid platform surface

Grab rail

ADA compliant telephone (optional)

Lighted and keyed control panel w/rocker switch and emergency stop with audio visual alarm

Bruno VPL-3300B Series 3-Gate Application Design and Planning Guide

bruno.com/cvpl | 1-800-848-30566

Lift Heights and Floor-to-Floor Measuring

3-Gate MeasuresModel Max Floor-to-Floor Min Floor-to-Floor Mast Height Unit Weight

VPL-3353B 53” 11” 75-9/16” 1027”

Platforms

The rated load for the platform is 750 lbs. Solid side platform walls measure 42” high. See below for typical platform features and components.

Platform Size Options: • 36” x 54” – standard • 36” x 48” • 36“ x 60”

Lift height is defined as the distance from the lower landing where the lift will be placed to the upper landing. The lift can be installed with or without a pit. In a pit Installation, the measurement is from the bottom of the pit to the upper landing. For a floor installation, the measurement is from the floor to the upper landing.

42” high sidewalls

Bottom platform safety panel

Non-skid platform surface

Grab rail

ADA compliant telephone (optional)

Lighted and keyed control panel w/rocker switch and emergency stop with audio visual alarm

PitLower Landing

LiftHeight

3” Pit Depth

Upper Landing

Pit installation = Pit to floor distance

Floor installation = Floor to floor distance

Lower Landing

Upper Landing

LiftHeight

PitLower Landing

LiftHeight

3” Pit Depth

Upper Landing

Pit installation = Pit to floor distance

Floor installation = Floor to floor distance

Lower Landing

Upper Landing

LiftHeight

Page 7: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

1-800-848-3056 | bruno.com/cvpl 7

Platform Configurations

Platforms can be designed in multiple on/off configurations including Straight Through (most common), 90°/Adjacent and Same Side. See images below.

Enclosure platform configuration availability by model:

Number of Landings: 2-stop (upper and lower) are available.

Model Straight Through 90° / Adjacent* Same SideVPL-3353B Yes Yes NoVPL-3375B Yes Yes NoVPL-3310B Yes Yes YesVPL-3312B Yes Yes YesVPL-3314B Yes Yes Yes

*See notes on page 11 if designing a 90° / Adjacent Platform.

PlatformOn/Off On/Off

Straight Through

Mast/Tower

PlatformOn/Off

On/Off

90°/Adjacent

Mast/Tower

PlatformOn/Off

Same Side

Mast/Tower

Page 8: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-30568

Operating Controls

Platform Controls: All Bruno VPL-3300B Series lifts come standard with weather-protected, continuous pressure up and down rocker switch platform control. Optional paddle style control is available.

Call/Sends: Optional remote call/send controls come in rocker or paddle style and either flush or surface mount installation. Used on upper and lower landings.

Upper Landing Controls: Optional upper landing gate controls are also available in both rocker or paddle style control.

Rocker Switch Platform Control Paddle Platform Control

Rocker / Surface mount Paddle / Flush Mount

Rocker Paddle

Page 9: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

1-800-848-3056 | bruno.com/cvpl 9

Additional Options

ADA Phone with Battery Backup Platform Gate Operator Doors and Upper Landing Gate Operator

Cold weather package: recommended if operating temperature is below 20°F (-7°C)

Cable carrier/guide

Hardware

Mounting bracket

Cold weather ACME screw grease

Junction box assembly

Battery warmers

Page 10: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-305610

Additional Options cont.

Battery Package Upgrade – 34AH (upgrade package for VPL-3353B & VPL-3375B only)

Pit SwitchMounts inside the enclosure and ensures safety of someone working beneath the platform.

Flood Sensor The flood sensor is used to detect water near the bottom of the VPL. The sensor can be mounted anywhere below the lower limit switches. When water is detected, the platform will stop moving in either up or down direction.

34AH Batteries

Page 11: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

1-800-848-3056 | bruno.com/cvpl 11

Bruno Enclosure Doors and Gates

The Enclosure model includes a full-size aluminum framed door with Plexiglas panels for the lower landing. This door is equipped with an electric strike interlock system (ESI), is non-fire rated and comes pre-hung in an aluminum frame (optional for use at the upper landing). The height of the door is 80” and is available in two widths: - 36” door (33-3/8” inside opening), 42” frame - 45” door (42-3/8” inside opening), 51” frame

Another option is Bruno’s upper landing gate includes Bruno’s electrical mechanical interlock (EMI) or optional electric strike interlock (ESI), which releases the gate when platform is at the upper landing. Electronic sensors stop the platform from operating unless the gate is closed. Rocker switch upper landing control comes mounted to the gate. Paddle switch and/or remote mount are optional. Available with steel or Plexiglas panels in two sizes: - 36” W x 42” H - 42” W x 42” H

Hand of Mast / Tower

Hand of mast / tower is determined by the side the mast / tower is on when entering the lift at the lower landing. See below.

Gate and Door Swing Direction

Identify gate or door swing based on the direction the gate or door opens from the platform (see drawing below). For example, if a user’s back is to the hinge and the right arm would be used to open the door or gate, it would require a right-hand swing.

Please note the following for most 90° / Adjacent Platforms: - Left hand mast / tower requires right hand upper landing gate with EMI interlock. - Right hand mast / tower requires left hand upper landing gate with EMI interlock. - If this configuration cannot be achieved due to any design or structure requirements, an upper landing gate with an ESI lock can be used and this requirement will not apply.

Low

er la

ndin

g

Mast / Tower

Platform

Left hand Mast / Tower

Low

er la

ndin

g

Mast / Tower

Platform

Right hand Mast / Tower

Mast / Tower

PlatformRH

LHLHRH

LHRH

Steel panel, rocker switch Plexiglas panel, paddle control

Page 12: Bruno VPL -3300B Series

Bruno VPL-3300B Series Enclosure Design and Planning Guide

bruno.com/cvpl | 1-800-848-305612

Site Construction Details

Electrical Requirements:Check applicable local codes for all electrical and wiring requirements. If it is determined that a GFI (Ground Fault Interrupter) outlet is required, use a GFI 120V, 15A, 60 Hz single phase circuit to operate the internal battery charger (charger draws 3A max.). National Electrical Code requires a GFI is used in all outdoor or wet environment applications.

Platform Pathway Requirements:Make sure the platform pathway is clear of any electrical conduit and wire ways. Make sure no liquids, steam or gas piping discharge into the pathway, and ensure that there is sufficient headroom clearance (minimum of 80”– 2032 mm) throughout floor-to-floor travel. The area should be sufficiently lit.

Floor Recommendations:A 4” (102 mm) thick, 3500 PSI minimum compressive strength, reinforced concrete slab. Refer to technical drawings for mini-mum slab dimensions. If the temperature can fall below freezing, it is recommended that you insert an insulation sheet between the concrete slab and the compacted rock.

Floor Attachment:VPL must be fastened to concrete slab using four (4) 1/2” (3/8” bolt) x minimum 2-1/2” long concrete anchors suitable for the environment. Refer to technical drawings for mounting hole locations. Follow selected concrete anchor manufacturer’s guidelines and applicable codes.

Top Landing Gate Attachment:Gate is mounted to the enclosure on the sides then secured to the top landing along the sill.

Space Requirements:Refer to application specific drawings starting on page 13.

Platform-to-Top Landing Sill Clearance:ASME code indicates the platform floor-to-sill clearance at the upper landing shall not be less than 3/8” (9.5 mm) nor exceed 3/4” (19 mm). Follow applicable local codes.

Fascia Wall Requirements:ASME code indicates that fascia should be smooth and/or non-perforated that guards the full length and width of the platform. The fascia wall is supplied with the enclosure.

Page 13: Bruno VPL -3300B Series

13

Ap

plic

atio

n S

pec

ific

Dra

win

gs

Low

Ris

e M

od

els

(V

PL-3

353B

an

d V

PL-3

375B

) St

raig

ht

thro

ug

h, n

o p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

/2 h

p m

otor

, 175

0 rp

m, 2

4 VD

C, c

ontin

uous

dut

y

Inte

rmed

iate

red

ucti

on: D

ual 4

L st

yle

Poly

-V b

elts

and

pul

leys

, 3.9

4:1

pulle

y re

duct

ion

Fi

nal d

rive

: 1”

dia.

ACM

E sc

rew

w/b

ronz

e nu

t and

bro

nze

safe

ty b

ack

up n

ut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8.1

(Sec

tion

2) S

afet

y St

anda

rds

for P

latfo

rm L

ifts

and

Stai

rway

Cha

irlift

sCS

A B3

55 L

ifts

for P

erso

ns w

ith P

hysi

cal D

isab

ilitie

sCS

A B4

4. 1

/ASM

E A1

7.5

Elev

ator

and

Esc

alat

or E

quip

men

t

ILS-

0121

5 -

Rev

. 3 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 14: Bruno VPL -3300B Series

14

G

M

JH

7 5/

16"

K

F

L

B

A

C

D

AB

C M

INC

MA

X

VPL-

3353

B75

-9/1

6”95

”11

”53

”VP

L-33

75B

97-9

/16”

117”

53”

75”

Low

Ris

e M

od

els

(V

PL-3

353B

an

d V

PL-3

375B

) St

raig

ht

thro

ug

h, n

o p

it

DF

GH

JK

LM

36”x

48”

Pla

tform

36-1

/4”

48”

8-1/

4”53

76-1

3/16

”91

-1/8

”31

-9/1

6”55

-1/4

”36

”x 5

4” P

latfo

rm36

-1/4

”48

”11

-1/4

”59

82-1

3/16

”97

-1/8

”31

-9/1

6”55

-1/4

”36

”x 6

0” P

latfo

rm36

-1/4

”48

”14

-1/4

”65

88-1

3/16

”10

3-1/

8”31

-9/1

6”55

-1/4

”42

”x 6

0” P

latfo

rm42

-1/4

”54

”14

-1/4

”65

88-1

3/16

”11

2-1/

8”34

-9/1

6”61

-1/4

ILS-

0121

5 -

Rev

. 3 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 15: Bruno VPL -3300B Series

15

An

cho

r p

oin

t lo

cati

on

s/sl

ab d

etai

l(V

PL-3

353B

an

d V

PL-3

375B

) St

raig

ht

thro

ug

h, n

o p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for t

he e

nviro

nmen

t. Fo

llow

sel

ecte

d co

ncre

te a

ncho

r man

ufac

ture

s gu

idel

ines

and

app

licab

le c

odes

.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

76”

58-9

/16”

5-15

/16”

45”

10-1

5/16

”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”82

”58

-9/1

6”8-

15/1

6”51

”10

-15/

16”

36”x

60”

Pla

tform

13-5

/8”

18-1

/16”

88”

58-9

/16”

11-1

5/16

”57

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

88”

64-9

/16”

11-1

5/16

”56

”16

-15/

16”

39 7

/8"

24 5

/16"

33 3

/16"

N

U

P

TS

3/8"

-3/4

"

3/8"

-3/4

"

32 3

/16"

4 1/

8"

Q

RILS-

0121

5 -

Rev

. 3 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 16: Bruno VPL -3300B Series

16A

pp

licat

ion

Sp

ecifi

c D

raw

ing

s

Low

Ris

e M

od

els

(V

PL-3

353B

an

d V

PL-3

375B

) St

raig

ht

thro

ug

h, w

ith

pit

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad

- 75

0 lb

s m

ax

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

/2 h

p m

otor

, 175

0 rp

m, 2

4 VD

C, c

ontin

uous

dut

y

Inte

rmed

iate

red

ucti

on: D

ual 4

L st

yle

Poly

-V b

elts

and

pul

leys

, 3.9

4:1

pulle

y re

duct

ion

Fi

nal d

rive

: 1”

dia.

ACM

E sc

rew

w/b

ronz

e nu

t and

bro

nze

safe

ty b

ack

up n

ut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0121

6 -

Rev

. 4 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 17: Bruno VPL -3300B Series

17

Low

Ris

e M

od

els

(V

PL-3

353B

an

d V

PL-3

375B

) St

raig

ht

thro

ug

h, w

ith

pit

G

M

H

K

F

L

C L

A

C

D

B7 5/

16"

DF

GH

KL

M36

”x 4

8” P

latfo

rm36

-1/4

”48

”8-

1/4”

53”

91-1

/8”

31-9

/16”

55-1

/4”

36”x

54”

Pla

tform

36-1

/4”

48”

11-1

/4”

59”

97-1

/8”

31-9

/16”

55-1

/4”

36”x

60”

Pla

tform

36-1

/4”

48”

14-1

/4”

65”

103-

1/8”

31-9

/16”

55-1

/4”

42”x

60”

Pla

tform

42-1

/4”

54”

14-1

/4”

65”

112-

1/8”

34-9

/16”

61-1

/4”

AB

C M

INC

MA

X

VPL-

3353

B75

-9/1

6”95

”11

”53

”VP

L-33

75B

97-9

/16”

117”

53”

75”

ILS-

0121

6 -

Rev

. 4 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 18: Bruno VPL -3300B Series

18A

nch

or

po

int

loca

tio

ns/

pit

det

ail

(VPL

-335

3B a

nd

VPL

-337

5B)

Stra

igh

t th

rou

gh

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for t

he e

nviro

nmen

t. Fo

llow

sel

ecte

d co

ncre

te a

ncho

r man

ufac

ture

s gu

idel

ines

and

app

licab

le c

odes

.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

39 7

/8"

24 5

/16"

33 3

/16"

N

U

P

TS

3/8"

-3/4

"

3/8"

-3/4

"

32 3

/16"

Q

R

1"

3/8"

-3/4

"3"

PI

T D

EPTH

39 7

/8"

24 5

/16"

33 3

/16"

N

U

P

TS

3/8"

-3/4

"

3/8"

-3/4

"

32 3

/16"

Q

R

1"

3/8"

-3/4

"3"

PI

T D

EPTH

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

53-3

/8”

57”

5-15

/16”

45”

10-1

5/16

”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”59

-3/8

”57

”8-

15/1

6”51

”10

-15/

16”

36”x

60”

Pla

tform

13-5

/8”

18-1

/16”

65-3

/8”

57”

11-1

5/16

”57

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

65-3

/8”

63”

11-1

5/16

”56

”16

-15/

16”

ILS-

0121

6 -

Rev

. 4 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 19: Bruno VPL -3300B Series

19

Low

Ris

e M

od

els

(V

PL-3

353B

an

d V

PL-3

375B

) En

clo

sure

90/

Ad

jace

nt

Plat

form

, no

pit

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

/2 h

p m

otor

, 175

0 rp

m, 2

4 VD

C, c

ontin

uous

dut

y

Inte

rmed

iate

red

ucti

on: D

ual 4

L st

yle

Poly

-V b

elts

and

pul

leys

, 3.9

4:1

pulle

y re

duct

ion

Fi

nal d

rive

: 1”

dia.

ACM

E sc

rew

w/b

ronz

e nu

t and

bro

nze

safe

ty b

ack

up n

ut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0124

1 -

Rev

. 4 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 20: Bruno VPL -3300B Series

20Lo

w R

ise

Mo

del

s (

VPL

-335

3B a

nd

VPL

-337

5B)

Encl

osu

re 9

0/A

dja

cen

t Pl

atfo

rm, n

o p

it

A

D

C

F

7 1/

4"

M

G

HJ

K

L B

C LD

FG

HJ

KL

M36

”x 4

8” P

latfo

rm36

-1/4

”48

-1/4

”10

-11/

16”

55-1

/2”

79-3

/8”

93-5

/8”

31-9

/16”

55-1

/2”

36”x

54”

Pla

tform

36-1

/4”

48-1

/4”

13-1

1/16

”61

-1/2

”85

-3/8

”99

-5/8

”31

-9/1

6”55

-1/2

”36

”x 6

0” P

latfo

rm36

-1/4

”48

-1/4

”16

-11/

16”

67-1

/2”

91-3

/8”

105-

5/8”

31-9

/16”

55-1

/2”

42”x

60”

Pla

tform

42-1

/4”

54-1

/4”

16-1

1/16

”67

-1/2

”91

-3/8

”11

4-5/

8”34

-9/1

6”61

-1/2

AB

C M

INC

MA

X

VPL-

3353

B75

-9/1

6”95

”11

”53

”VP

L-33

75B

97-9

/16”

117”

53”

75”

ILS-

0124

1 -

Rev

. 4 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 21: Bruno VPL -3300B Series

21

An

cho

r p

oin

t lo

cati

on

s/sl

ab d

etai

l(V

PL-3

353B

an

d V

PL-3

375B

) En

clo

sure

90/

Ad

jace

nt

pla

tfo

rm, n

o p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for t

he e

nviro

nmen

t. Fo

llow

sel

ecte

d co

ncre

te a

ncho

r man

ufac

ture

s gu

idel

ines

and

app

licab

le c

odes

.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

80”

58-3

/4”

8-3/

8”47

-1/2

”11

-1/1

6”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”86

”58

-3/4

”11

-3/8

”53

-1/2

”11

-1/1

6”36

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”92

”58

-3/4

”14

-3/8

”59

-1/2

”11

-1/1

6”42

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”92

”64

-3/4

”14

-3/8

”59

-1/2

”17

-1/1

6”

3/8"

-3/4

"

3/8"

-3/4

"

3"

24 5

/16"

T

33 3

/16"

P

39 7

/8"

4 1/

8"

32 3

/16"

Q

R

U

SN

ILS-

0124

1 -

Rev

. 4 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 22: Bruno VPL -3300B Series

22Lo

w R

ise

Mo

del

s (V

PL-3

353B

an

d V

PL-3

375B

)En

clo

sure

90°

/Ad

jace

nt

Plat

form

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

/2 h

p m

otor

, 175

0 rp

m, 2

4 VD

C, c

ontin

uous

dut

y

Inte

rmed

iate

red

ucti

on: D

ual 4

L st

yle

Poly

-V b

elts

and

pul

leys

, 3.9

4:1

pulle

y re

duct

ion

Fi

nal d

rive

: 1”

dia.

ACM

E sc

rew

w/b

ronz

e nu

t and

bro

nze

safe

ty b

ack

up n

ut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0124

2 -

Rev

. 4 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 23: Bruno VPL -3300B Series

23

Low

Ris

e M

od

els

(VPL

-335

3B a

nd

VPL

-337

5B)

Encl

osu

re 9

0°/A

dja

cen

t Pl

atfo

rm, w

ith

pit

A

D

C

F

7 1/

4"

M

G

H

K

L B

C LPL

ATF

ORM

DF

GH

JK

LM

36”x

48”

Pla

tform

36-1

/4”

48-1

/4”

10-1

1/16

”55

-1/2

”79

-3/8

”93

-5/8

”31

-9/1

6”55

-1/2

”36

”x 5

4” P

latfo

rm36

-1/4

”48

-1/4

”13

-11/

16”

61-1

/2”

85-3

/8”

99-5

/8”

31-9

/16”

55-1

/2”

36”x

60”

Pla

tform

36-1

/4”

48-1

/4”

16-1

1/16

”67

-1/2

”91

-3/8

”10

5-5/

8”31

-9/1

6”55

-1/2

”42

”x 6

0” P

latfo

rm42

-1/4

”54

-1/4

”16

-11/

16”

67-1

/2”

91-3

/8”

114-

5/8”

34-9

/16”

61-1

/2”

AB

C M

INC

MA

X

VPL-

3353

B75

-9/1

6”95

”11

”53

”VP

L-33

75B

97-9

/16”

117”

53”

75”

ILS-

0124

2 -

Rev

. 4 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 24: Bruno VPL -3300B Series

24A

nch

or

po

int

loca

tio

ns/

pit

det

ail

(VPL

-335

3B a

nd

VPL

-337

5B)

Encl

osu

re 9

0/A

dja

cen

t p

latf

orm

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for

the

envi

ronm

ent.

Follo

w s

elec

ted

conc

rete

anc

hor m

anuf

actu

res

guid

elin

es a

nd a

pplic

able

cod

es.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

55-7

/8”

56-1

/2”

8-3/

8”47

-1/2

”11

-1/1

6”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”61

-7/8

”56

-1/2

”11

-3/8

”53

-1/2

”11

-1/1

6”36

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”67

-7/8

”56

-1/2

”14

-3/8

”59

-1/2

”11

-1/1

6”42

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”67

-7/8

”62

-1/2

”14

-3/8

”59

-1/2

”17

-1/1

6”

3/8"

-3/4

"

3/8"

-3/4

"

3"

24 5

/16"

TQ

R

3/8"

-3/4

"

33 3

/16"

P

39 7

/8" 32

3/1

6"

U

SN

3/8"

-3/4

"

3/8"

-3/4

"

3"

24 5

/16"

TQ

R

3/8"

-3/4

"

33 3

/16"

P

39 7

/8" 32

3/1

6"

U

SN

ILS-

0124

2 -

Rev

. 4 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 25: Bruno VPL -3300B Series

25

Tall

Mo

del

s (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

ame

Sid

e Pl

atfo

rm, n

o p

itTe

chn

ical

Dat

a/Sp

ecifi

cati

on

s

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

hp

mot

or, 1

750

rpm

, 24

VDC,

con

tinuo

us d

uty

In

term

edia

te r

educ

tion

: Dua

l 4L

styl

e Po

ly-V

bel

ts a

nd p

ulle

ys, 3

.94:

1 pu

lley

redu

ctio

n

Fina

l dri

ve: 1

1/4

” A

CME

scre

w w

/bro

nze

nut a

nd b

ronz

e sa

fety

bac

k up

nut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0128

9 -

Rev

. 4 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 26: Bruno VPL -3300B Series

26

B

K

J

G

H

7 1/

4" FM

L

C

D

A

Tall

Mo

del

s (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

ame

Sid

e Pl

atfo

rm, n

o p

it

DF

GH

JK

LM

36”x

48”

Pla

tform

36-1

/4”

48”

10-1

1/16

”55

-1/2

”79

-3/8

”93

-5/8

”31

-9/1

6”55

-1/4

”36

”x 5

4” P

latfo

rm36

-1/4

”48

”13

-11/

16”

61-1

/2”

85-3

/8”

99-5

/8”

31-9

/16”

55-1

/4”

36”x

60”

Pla

tform

36-1

/4”

48”

16-1

1/16

”67

-1/2

”91

-3/8

”10

5-5/

8”31

-9/1

6”55

-1/4

”42

”x 6

0” P

latfo

rm42

-1/4

”54

”16

-11/

16”

67-1

/2”

91-3

/8”

114-

5/8”

34-9

/16”

61-1

/4”

Mo

del

AB

C M

INC

MA

X

VPL-

3310

B14

8-1/

16”

165”

86”

123”

VPL-

3312

B17

2-1/

16”

189”

86”

147”

VPL-

3314

B19

6-1/

16”

213”

86”

171”

ILS-

0128

9 -

Rev

. 4 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 27: Bruno VPL -3300B Series

27

An

cho

r p

oin

t lo

cati

on

s/sl

ab d

etai

l (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

ame

Sid

e Pl

atfo

rm, n

o p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for t

he e

nviro

nmen

t. Fo

llow

sel

ecte

d co

ncre

te a

ncho

r m

anuf

actu

res

guid

elin

es a

nd a

pplic

able

cod

es.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

24 5

/16"

39 7

/8"

32 3

/16"

33 3

/16"

P

3/8"

-3/4

"

3" U

S N

T

4 1/

8"

R

QM

IN. S

LAB

LAN

DIN

G G

ATE

END

OF

ENCL

OSU

RE

MIN

.SL

AB

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

80”

58-9

/16”

8-3/

8”47

-1/2

”10

-15/

16”

36”x

54”

Pla

tform

10-5

/8”

15-1

/16”

86”

58-9

/16”

11-3

/8”

53-1

/2”

10-1

5/16

”36

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”92

”58

-9/1

6”14

-3/8

”59

-1/2

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

92”

64-9

/16”

14-3

/8”

59-1

/2”

16-1

5/16

ILS-

0128

9 -

Rev

. 4 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 28: Bruno VPL -3300B Series

28Ta

ll M

od

els

(VPL

-331

0B, V

PL-3

312B

an

d V

PL-3

314B

)En

clo

sure

Sam

e Si

de

Plat

form

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

hp

mot

or, 1

750

rpm

, 24

VDC,

con

tinuo

us d

uty

In

term

edia

te r

educ

tion

: Dua

l 4L

styl

e Po

ly-V

bel

ts a

nd p

ulle

ys, 3

.94:

1 pu

lley

redu

ctio

n

Fina

l dri

ve: 1

1/4

” A

CME

scre

w w

/bro

nze

nut a

nd b

ronz

e sa

fety

bac

k up

nut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0129

0 -

Rev

. 4 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 29: Bruno VPL -3300B Series

29

Tall

Mo

del

s (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

ame

Sid

e Pl

atfo

rm, w

ith

pit

B

SILL

PLA

TEO

F U

PPER

LAN

DIN

GG

ATE

KG

7 1/

4" FM

H

L

CIRC

UIT

BREA

KER

BOX

3" PIT

C

D

NO

TE: D

OO

R W

ILL

NO

T O

PEN

IF P

IT IS

OVE

R 3"

UPP

ER L

ANDI

NG

GAT

E N

OT

SHO

WN

TOP

OF

PLAT

FORM

DECK

A

LEFT

OR

RIG

HT H

AND

SWIN

G L

ANDI

NG

GAT

ES

FLO

OR

TOFL

OO

R

C L P

LATF

ORM

LEFT

OR

RIG

HTHA

ND

SWIN

GDO

OR

DF

GH

KL

M36

”x 4

8” P

latfo

rm36

-1/4

”48

”10

-11/

16”

55-1

/2”

93-5

/8”

31-9

/16”

55-1

/4”

36”x

54”

Pla

tform

36-1

/4”

48”

13-1

1/16

”61

-1/2

”99

-5/8

”31

-9/1

6”55

-1/4

”36

”x 6

0” P

latfo

rm36

-1/4

”48

”16

-11/

16”

67-1

/2”

105-

5/8”

31-9

/16”

55-1

/4”

42”x

60”

Pla

tform

42-1

/4”

54”

16-1

1/16

”67

-1/2

”11

4-5/

8”34

-9/1

6”61

-1/4

Mo

del

AB

C M

INC

MA

X

VPL-

3310

B14

8-1/

16”

165”

86”

123”

VPL-

3312

B17

2-1/

16”

189”

86”

147”

VPL-

3314

B19

6-1/

16”

213”

86”

171”

ILS-

0129

0 -

Rev

. 4 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 30: Bruno VPL -3300B Series

30A

nch

or

po

int

loca

tio

ns/

pit

det

ail

(VPL

-331

0B, V

PL-3

312B

an

d V

PL-3

314B

)En

clo

sure

Sam

e Si

de

Plat

form

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for

the

envi

ronm

ent.

Follo

w s

elec

ted

conc

rete

anc

hor m

anuf

actu

res

guid

elin

es a

nd a

pplic

able

cod

es.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

55-7

/8”

57”

8-3/

8”47

-1/2

”10

-15/

16”

36”x

54”

Pla

tform

10-5

/8”

15-1

/16”

61-7

/8”

57”

11-3

/8”

53-1

/2”

10-1

5/16

”36

”x 6

0” P

latfo

rm13

-5/8

”18

-1/1

6”67

-7/8

”57

”14

-3/8

”59

-1/2

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

67-7

/8”

63”

14-3

/8”

59-1

/2”

16-1

5/16

24 5

/16"

39 7

/8"

33 3

/16"

P

3" U

3/8"

-3/4

"

ST

N

32 3

/16"

R

4 1/

8"

Q

3"

24 5

/16"

39 7

/8"

33 3

/16"

P

3" U

3/8"

-3/4

"

ST

N

32 3

/16"

R

4 1/

8"

Q

3"

ILS-

0129

0 -

Rev

. 4 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 31: Bruno VPL -3300B Series

31

Tall

Mo

del

s (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

trai

gh

t Th

rou

gh

Pla

tfo

rm, n

o p

itTe

chn

ical

Dat

a/Sp

ecifi

cati

on

s

Rate

d lo

ad -

750

lbs

max

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

hp

mot

or, 1

750

rpm

, 24

VDC,

con

tinuo

us d

uty

In

term

edia

te r

educ

tion

: Dua

l 4L

styl

e Po

ly-V

bel

ts a

nd p

ulle

ys, 3

.94:

1 pu

lley

redu

ctio

n

Fina

l dri

ve: 1

1/4

” A

CME

scre

w w

/bro

nze

nut a

nd b

ronz

e sa

fety

bac

k up

nut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0127

7 -

Rev

. 1 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 32: Bruno VPL -3300B Series

32Ta

ll M

od

els

(VPL

-331

0B, V

PL-3

312B

an

d V

PL-3

314B

)En

clo

sure

Str

aig

ht

Thro

ug

h P

latf

orm

, no

pit

B

GK

HJ

7 1/

4" FM

L

A

C

D

DF

GH

JK

LM

36”x

48”

Pla

tform

36-1

/4”

48”

8-1/

4”53

”76

-13/

16”

91-1

/8”

31-9

/16”

55-1

/4”

36”x

54”

Pla

tform

36-1

/4”

48”

11-1

/4”

59”

82-1

3/16

”97

-1/8

”31

-9/1

6”55

-1/4

”36

”x 6

0” P

latfo

rm36

-1/4

”48

”14

-1/4

”65

”88

-13/

16”

103-

1/8”

31-9

/16”

55-1

/4”

42”x

60”

Pla

tform

42-1

/4”

54”

14-1

/4”

65”

88-1

3/16

”11

2-1/

8”34

-9/1

6”61

-1/4

Mo

del

AB

C M

INC

MA

X

VPL-

3310

B14

8-1/

16”

165”

75”

123”

VPL-

3312

B17

2-1/

16”

189”

75”

147”

VPL-

3314

B19

6-1/

16”

213”

75”

171”

ILS-

0127

7 -

Rev

. 1 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 33: Bruno VPL -3300B Series

33

An

cho

r p

oin

t lo

cati

on

s/sl

ab d

etai

l(V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

ame

Sid

e Pl

atfo

rm, n

o p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for t

he e

nviro

nmen

t. Fo

llow

sel

ecte

d co

ncre

te

anch

or m

anuf

actu

res

guid

elin

es a

nd a

pplic

able

cod

es.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

76”

58-9

/16”

5-15

/16”

45”

10-1

5/16

”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”82

”58

-9/1

6”8-

15/1

6”51

”10

-15/

16”

36”x

60”

Pla

tform

13-5

/8”

18-1

/16”

88”

58-9

/16”

11-1

5/16

”57

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

88”

64-9

/16”

11-1

5/16

”56

”16

-15/

16”

24 5

/16"

P

39 7

/8"

3/8"

-3/4

"

32 3

/16"

U

3/8"

-3/4

"

ST

N33

3/1

6"

Q

4 1/

8"

R

MIN

. SLA

B

LAN

DIN

G G

ATE

END

OF

ENCL

OSU

RE

MIN

.SL

AB

ILS-

0127

7 -

Rev

. 1 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 34: Bruno VPL -3300B Series

34Ta

ll M

od

els

(VPL

-331

0B, V

PL-3

312B

an

d V

PL-3

314B

)En

clo

sure

Str

aig

ht

Thro

ug

h P

latf

orm

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Rate

d lo

ad

- 75

0 lb

s m

ax

Inpu

t po

wer

sou

rce

- D

C ba

tter

y po

wer

ed u

nit:

110

-120

vol

t - 3

Am

p 60

Hz

batt

ery

char

ger

Dri

ve -

DC

batt

ery

pow

ered

uni

t: 1

hp

mot

or, 1

750

rpm

, 24

VDC,

con

tinuo

us d

uty

In

term

edia

te r

educ

tion

: Dua

l 4L

styl

e Po

ly-V

bel

ts a

nd p

ulle

ys, 3

.94:

1 pu

lley

redu

ctio

n

Fina

l dri

ve: 1

1/4

” A

CME

scre

w w

/bro

nze

nut a

nd b

ronz

e sa

fety

bac

k up

nut

Mot

or c

ontr

olle

r -

DC

batt

ery

pow

ered

uni

t: 2

4 VD

C re

lay

cont

rol

Spee

d -

DC

batt

ery

pow

ered

uni

t: 1

0 ft

per m

inut

e m

axim

um

For

com

ple

te t

ech

nic

al s

pec

ifica

tio

ns,

ple

ase

see

ILS-

0110

0 “V

PL-3

300B

Ser

ies

Co

mm

erci

al V

erti

cal P

latf

orm

Lif

t Te

chn

ical

Sp

ecifi

cati

on

.”

Perf

orm

ance

Sta

nd

ard

s

USA

Foo

d &

Dru

g Ad

min

istr

atio

n: C

lass

II, 5

10(K

) Exe

mpt

, File

No.

890

.393

0 Pr

oduc

t Cod

e: P

CE

ASM

E A1

8. (S

ectio

n 2)

Saf

ety

Stan

dard

s fo

r Pla

tform

Lift

s an

d St

airw

ay C

hairl

ifts

CSA

B355

Lift

s fo

r Per

sons

with

Phy

sica

l Dis

abili

ties

CSA

B44.

1/A

SME

A17.

5 El

evat

or a

nd E

scal

ator

Equ

ipm

ent

ILS-

0127

8 -

Rev

. 3 •

Sh

eet

1 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 35: Bruno VPL -3300B Series

35

Tall

Mo

del

s (V

PL-3

310B

, VPL

-331

2B a

nd

VPL

-331

4B)

Encl

osu

re S

trai

gh

t Th

rou

gh

Pla

tfo

rm, w

ith

pit

B

GK

H

7 1/

4" FM

L

A

C

D

DF

GH

KL

M36

”x 4

8” P

latfo

rm36

-1/4

”48

”8-

1/4”

53”

91-1

/8”

31-9

/16”

55-1

/4”

36”x

54”

Pla

tform

36-1

/4”

48”

11-1

/4”

59”

97-1

/8”

31-9

/16”

55-1

/4”

36”x

60”

Pla

tform

36-1

/4”

48”

14-1

/4”

65”

103-

1/8”

31-9

/16”

55-1

/4”

42”x

60”

Pla

tform

42-1

/4”

54”

14-1

/4”

65”

112-

1/8”

34-9

/16”

61-1

/4”

Mo

del

AB

C M

INC

MA

X

VPL-

3310

B14

8-1/

16”

165”

75”

123”

VPL-

3312

B17

2-1/

16”

189”

75”

147”

VPL-

3314

B19

6-1/

16”

213”

75”

171”

ILS-

0127

8 -

Rev

. 3 •

Sh

eet

2 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 36: Bruno VPL -3300B Series

36A

nch

or

po

int

loca

tio

ns/

pit

det

ail

(VPL

-331

0B, V

PL-3

312B

an

d V

PL-3

314B

)En

clo

sure

Str

aig

ht

thro

ug

h P

latf

orm

, wit

h p

it

Tech

nic

al D

ata/

Spec

ifica

tio

ns

Floo

r Att

achm

ent

VPL

mus

t be

fast

ened

to c

oncr

ete

slab

usi

ng fo

ur (4

) 1/2

” (3

/8”

bolt)

x m

inim

um 2

-1/2

” lo

ng c

oncr

ete

anch

ors

suita

ble

for

the

envi

ronm

ent.

Follo

w s

elec

ted

conc

rete

anc

hor m

anuf

actu

res

guid

elin

es a

nd a

pplic

able

cod

es.

Floo

r Re

quir

emen

ts4”

thic

k 35

00 P

SI m

inim

um c

ompr

essi

ve s

tren

gth,

rein

forc

ed c

oncr

ete

slab

NP

QR

ST

U36

”x 4

8” P

latfo

rm7-

5/8”

12-1

/16”

53-3

/8”

57”

5-15

/16”

45”

10-1

5/16

”36

”x 5

4” P

latfo

rm10

-5/8

”15

-1/1

6”59

-3/8

”57

”8-

15/1

6”51

”10

-15/

16”

36”x

60”

Pla

tform

13-5

/8”

18-1

/16”

65-3

/8”

57”

11-1

5/16

”57

”10

-15/

16”

42”x

60”

Pla

tform

13-5

/8”

18-1

/16”

65-3

/8”

63”

11-1

5/16

”56

”16

-15/

16”

24 5

/16"

P

39 7

/8"

3/8"

-3/4

"

32 3

/16"

U

3/8"

-3/4

"

ST

N33

3/1

6"

R

Q24

5/1

6"P

39 7

/8"

3/8"

-3/4

"

32 3

/16"

U

3/8"

-3/4

"

ST

N33

3/1

6"

R

Q

ILS-

0127

8 -

Rev

. 3 •

Sh

eet

3 o

f 3

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 37: Bruno VPL -3300B Series

37

Lan

din

g G

ate

Det

ail

VPL

-330

0B S

erie

s(V

iew

ed a

t to

p la

nd

ing

)

No

te: A

ll d

imen

sio

ns

app

licab

le f

or

LH o

r R

H la

nd

ing

gat

e

CA

AB

C36

” G

ate

36”

42-1

/2”

44”

42”

Gat

e42

”48

-1/2

”50

ILS-

0093

8 -

Rev

. 5 •

Sh

eet

1 o

f 4

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 38: Bruno VPL -3300B Series

38

DO

NO

T D

RILL

THIS

ARE

A

E

DO

NO

T D

RILL

THIS

ARE

A

Righ

t H

and

Uni

tE

Left

Hand

Gat

e10

-1/4

”Ri

ght H

and

Gat

e8-

1/2”

Left

Han

d U

nit

ELe

ft Ha

nd G

ate

8-1/

2”Ri

ght H

and

Gat

e10

-1/4

Lan

din

g G

ate

Det

ail

VPL

-330

0B S

erie

s St

raig

ht

thro

ug

h P

latf

orm

(V

iew

ed a

t to

p la

nd

ing

)

No

te: A

ll d

imen

sio

ns

app

licab

le f

or

LH o

r R

H la

nd

ing

gat

e

Top

vie

w o

f p

latf

orm

an

d t

op

lan

din

g g

ate.

Ref

er t

o s

hee

t 1

for

gat

e d

imen

sio

ns.

ILS-

0093

8 -

Rev

. 5 •

Sh

eet

2 o

f 4

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 39: Bruno VPL -3300B Series

39

Lan

din

g G

ate

Det

ail

VPL

-330

0B S

erie

s 90

° /

Ad

jace

nt

Exit

Pla

tfo

rm(V

iew

ed a

t to

p la

nd

ing

)

RIG

HT H

AND

UN

ITW

ITH

LEFT

HAN

DG

ATE

SHO

WN

DO

NO

T D

RILL

THIS

ARE

A

DO

NO

T D

RILL

THIS

ARE

A

Top

vie

w o

f p

latf

orm

an

d t

op

la

nd

ing

gat

e.R

efer

to

sh

eet

1 fo

r g

ate

dim

ensi

on

s.

ILS-

0093

8 -

Rev

. 5 •

Sh

eet

3 o

f 4

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Page 40: Bruno VPL -3300B Series

40La

nd

ing

Gat

e D

etai

lV

PL-3

300B

Ser

ies

Sam

e Si

de

Plat

form

(Vie

wed

at

top

lan

din

g)

E

LAN

DIN

G G

ATE

DO

NO

T D

RILL

THIS

ARE

A

DO

NO

T D

RILL

THIS

ARE

A

Top

vie

w o

f p

latf

orm

an

d t

op

lan

din

g g

ate.

Ref

er t

o s

hee

t 1

for

gat

e d

imen

sio

ns.

ILS-

0093

8 -

Rev

. 5 •

Sh

eet

4 o

f 4

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Righ

t H

and

Uni

tE

Left

Hand

Gat

e8-

1/2”

Righ

t Han

d G

ate

10-1

/4”

Left

Han

d U

nit

ELe

ft Ha

nd G

ate

10-1

/4”

Righ

t Han

d G

ate

8-1/

2”

Page 41: Bruno VPL -3300B Series

80 1

/8"

84 1

/8"

87 1

/8"

CHA

NN

ELSI

LL---

----

87 3

/8"

AN

GLE

SILL

1/4"

87 5

/8"

ROUG

HO

PEN

ING

(CHA

NN

EL S

ILL

FLO

OR

ATT

AC

HMEN

T)

84 7

/8"

ROUG

HO

PEN

ING

(WA

LLO

R PI

TA

TTA

CHM

ENT)

CA

LL/S

END

CO

NTR

OL

(OPT

ION

AL)

ELEC

TRIC

STR

IKE

INTE

RLO

CK

(ESI

)

CA

P W

ITH C

PP-2

0301

IF N

EED

ED (Q

TY. 2

)(O

RDER

SEP

ERA

TELY

)

4"

3 1/

4"

2"

3"

THER

E A

RE 3

MO

UNTIN

GHO

LES

(7/1

6" D

IA.)

ON

EAC

H SI

DE

OF

THE

DO

OR

FRA

ME

TO S

ECUR

E TH

ED

OO

R TO

THE

WA

LLS. 3"

2 3/

4"2"

DO

OR

CLO

SER

PRO

VID

ED(R

EMO

VED

BY

INST

ALL

ER IF

INST

ALL

ING

A D

OO

R O

PEN

ER)

CHA

NN

EL S

ILL

SCRE

W T

O P

ITO

R FL

OO

R

AN

GLE

SIL

LSC

REW

TO

WA

LL O

R PI

T

CLE

AR

OPE

NIN

G

DO

OR

OPE

N 9

0

AN

GLE

SIL

LW

ALL

OR

PIT

ATT

AC

HMEN

T(H

OIS

TWA

Y/SH

AFT

WA

Y)

CHA

NN

EL S

ILL

PIT

ATT

AC

HMEN

T(B

RUN

O E

NC

LOSU

RE)

CHA

NN

EL S

ILL

FLO

OR

ATT

AC

HMEN

T(F

IXED

RA

MP

ATT

AC

HMEN

T)

AN

GLE

SILL

CHA

NN

ELSI

LL

ROUG

H O

PEN

ING

(B +

1/2

")

41

ILS-

0119

4 -

Rev

. 2 •

Sh

eet

1 o

f 5

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Des

crip

tio

n‘A

’‘B

’‘C

’‘D

’‘E

’Flu

sh m

ount

36”

alum

inum

doo

r36

”42

”42

-1/2

”33

-3/8

”38

-1/8

”Flu

sh m

ount

45”

alum

inum

doo

r45

”51

”51

-1/2

”42

-3/8

”47

-1/8

Note

s:1.

Two

piec

es o

f ver

tical

fram

e tri

m is

inclu

ded.

Trim

can

be u

sed

as n

eede

d w

hen

insta

lling

the

door

.2.

Dea

ler to

supp

ly m

ount

ing

hard

war

e (i.

e. sc

rew

s, an

chor

s).3.

Pane

l inse

rt m

ater

ial is

eith

er cl

ear a

cryli

c or b

ronz

e ac

rylic

. Pan

els a

re sh

ippe

d w

ith a

pro

tect

ive p

aper

to b

e re

mov

ed b

y ins

talle

r4.

Whe

n an

gle

sill is

use

d in

a p

it, p

it de

pth

shou

ld b

e at

leas

t 3”

5. W

hen

chan

nel s

ill is

used

in a

pit,

pit

dept

h sh

ould

be

3” (d

oor w

ill no

t ope

n if

pit i

s ove

r 3”)

.

Flu

sh m

ou

nt

alu

min

um

do

or

det

ail -

LH

Sw

ing

Page 42: Bruno VPL -3300B Series

80 1

/8"

87 1

/8"

CHA

NN

ELSI

LL---

----

87 3

/8"

AN

GLE

SILL

84 1

/8"

1/4"

84 7

/8"

ROUG

HO

PEN

ING

(WA

LLO

R PI

TA

TTA

CHM

ENT)

87 5

/8"

ROUG

HO

PEN

ING

(CHA

NN

EL S

ILL

FLO

OR

ATT

AC

HMEN

T)

ELEC

TRIC

STR

IKE

INTE

RLO

CK

(ESI

)

CA

LL/S

END

CO

NTR

OL

(OPT

ION

AL)

CA

P W

ITH C

PP-2

0301

IF N

EED

ED (Q

TY. 2

)(O

RDER

SEP

ERA

TELY

)

AN

GLE

SIL

LSC

REW

TO

WA

LL O

R PI

T

CHA

NN

EL S

ILL

SCRE

W T

O P

ITO

R FL

OO

R

2"

3 1/

4"

4"

3"

THER

E A

RE 3

MO

UNTIN

GHO

LES

(7/1

6" D

IA.)

ON

EAC

H SI

DE

OF

THE

DO

OR

FRA

ME

TO S

ECUR

E TH

ED

OO

R TO

THE

WA

LLS.

2"

3"

2 3/

4"

DO

OR

CLO

SER

PRO

VID

ED(R

EMO

VED

BY

INST

ALL

ER IF

INST

ALL

ING

A D

OO

R O

PEN

ER)

AN

GLE

SILL

CHA

NN

ELSI

LL

AN

GLE

SIL

LW

ALL

OR

PIT

ATT

AC

HMEN

T(H

OIS

TWA

Y/SH

AFT

WA

Y)

CHA

NN

EL S

ILL

PIT

ATT

AC

HMEN

T(B

RUN

O E

NC

LOSU

RE)

CHA

NN

EL S

ILL

FLO

OR

ATT

AC

HMEN

T(F

IXED

RA

MP

ATT

AC

HMEN

T)

CLE

AR

OPE

NIN

G

ROUG

H O

PEN

ING

(B +

1/2

")

DO

OR

OPE

N 9

0

42

ILS-

0119

4 -

Rev

. 2 •

Sh

eet

2 o

f 5

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Des

crip

tio

n‘A

’‘B

’‘C

’‘D

’‘E

’Flu

sh m

ount

36”

alum

inum

doo

r36

”42

”42

-1/2

”33

-3/8

”38

-1/8

”Flu

sh m

ount

45”

alum

inum

doo

r45

”51

”51

-1/2

”42

-3/8

”47

-1/8

Flu

sh m

ou

nt

alu

min

um

do

or

det

ail -

RH

Sw

ing

Note

s:1.

Two

piec

es o

f ver

tical

fram

e tri

m is

inclu

ded.

Trim

can

be u

sed

as n

eede

d w

hen

insta

lling

the

door

.2.

Dea

ler to

supp

ly m

ount

ing

hard

war

e (i.

e. sc

rew

s, an

chor

s).3.

Pane

l inse

rt m

ater

ial is

eith

er cl

ear a

cryli

c or b

ronz

e ac

rylic

. Pan

els a

re sh

ippe

d w

ith a

pro

tect

ive p

aper

to b

e re

mov

ed b

y ins

talle

r4.

Whe

n an

gle

sill is

use

d in

a p

it, p

it de

pth

shou

ld b

e at

leas

t 3”

5. W

hen

chan

nel s

ill is

used

in a

pit,

pit

dept

h sh

ould

be

3” (d

oor w

ill no

t ope

n if

pit i

s ove

r 3”)

.

Page 43: Bruno VPL -3300B Series

43

ILS-

0119

4 -

Rev

. 2 •

Sh

eet

3 o

f 5

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Do

or

Size

Do

or

Loca

tio

nD

oo

r Sw

ing

LH U

nit

‘F’

RH

Un

it ‘F

’36

”Lo

wer

land

ing

Left

swin

g do

or11

-5/8

”9-

1/8”

36”

Low

er la

ndin

gRi

ght s

win

g do

or9-

1/8”

11-5

/8”

36”

Upp

er la

ndin

gLe

ft sw

ing

door

9-1/

8”11

-5/8

”36

”U

pper

land

ing

Righ

t sw

ing

door

11-5

/8”

9-1/

8”45

”Lo

wer

land

ing

Left

swin

g do

or10

-1/8

”7-

5/8”

45”

Low

er la

ndin

gRi

ght s

win

g do

or7-

5/8”

10-1

/8”

45”

Upp

er la

ndin

gLe

ft sw

ing

door

7-5/

8”10

-1/8

”45

”U

pper

land

ing

Righ

t sw

ing

door

10-1

/8”

7-5/

8”

Flu

sh m

ou

nt

alu

min

um

do

or

alig

nm

ent

Stra

igh

t th

rou

gh

pla

tfo

rm -

pla

n v

iew

s

Page 44: Bruno VPL -3300B Series

44

ILS-

0119

4 -

Rev

. 2 •

Sh

eet

4 o

f 5

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Plat

form

Siz

eD

oo

r Si

zeD

oo

r Lo

cati

on

Do

or

Swin

gLH

Un

it ‘G

’R

H U

nit

‘G’

36”

36”

Low

er la

ndin

gLe

ft sw

ing

door

11-5

/8”

9-1/

8”36

”36

”Lo

wer

land

ing

Righ

t sw

ing

door

9-1/

8”11

-5/8

”36

”45

”U

pper

land

ing

Left

swin

g do

orFlu

sh1”

36”

45”

Upp

er la

ndin

gRi

ght s

win

g do

or1”

Flush

42”

45”

Low

er la

ndin

gLe

ft sw

ing

door

10-1

/8”

7-5/

8”42

”45

”Lo

wer

land

ing

Righ

t sw

ing

door

7-5/

8”10

-5/8

”42

”45

”U

pper

land

ing

Left

swin

g do

orFlu

sh1”

42”

45”

Upp

er la

ndin

gRi

ght s

win

g do

or1”

Flush

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

Flu

sh m

ou

nt

alu

min

um

do

or

alig

nm

ent

90°/

Ad

jace

nt

exit

pla

tfo

rm-

pla

n v

iew

s

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

45” D

OOR

Page 45: Bruno VPL -3300B Series

45

ILS-

0119

4 -

Rev

. 2 •

Sh

eet

5 o

f 5

brun

o.co

m/c

vpl |

1-8

00-8

48-3

056

Flu

sh m

ou

nt

alu

min

um

do

or

alig

nm

ent

Sam

e si

de

pla

tfo

rm -

Pla

n v

iew

s

Do

or

Size

Do

or

Loca

tio

nD

oo

r Sw

ing

LH U

nit

‘H’

RH

Un

it ‘H

’36

”Lo

wer

land

ing

Left

swin

g do

or11

-5/8

”9-

1/8”

36”

Low

er la

ndin

gRi

ght s

win

g do

or9-

1/8”

11-5

/8”

36”

Upp

er la

ndin

gLe

ft sw

ing

door

11-5

/8”

9-1/

8”36

”U

pper

land

ing

Righ

t sw

ing

door

9-1/

8”11

-5/8

”45

”Lo

wer

land

ing

Left

swin

g do

or10

-1/8

”7-

5/8”

45”

Low

er la

ndin

gRi

ght s

win

g do

or7-

5/8”

10-1

/8”

45”

Upp

er la

ndin

gLe

ft sw

ing

door

10-1

/8”

7-5/

8”45

”U

pper

land

ing

Righ

t sw

ing

door

7-5/

8”10

-1/8

Page 46: Bruno VPL -3300B Series

1-800-848-3056 | bruno.com/cvpl