BROOKFIELD AMETEK PROCESS VISCOMETERS AST-102FTSY Viscometer

2
BROOKFIELD AMETEK PROCESS VISCOMETERS AST-102FTSY Viscometer in-line viscosity control for increased production at lower costs No moving parts to wear, bind or contact process materials No narrow gaps to trap product Simple clean-in-place design complies with 3A standard Rugged 316L stainless steel construction Continuous, reliable 4-20 mA, RS232 or RS485 output Model AST-330SY Viscosity Controller (optional) PLC based single station controller allows operator interface and modification. Various screen options include active bar graph and time adjustable trend history graphs. Compliant to 3A sanitary standards TEL 800-628-8139 or 508-946-6200 FAX 508-946-6262 www.brookfieldengineering.com (ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 Garches Tél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com

Transcript of BROOKFIELD AMETEK PROCESS VISCOMETERS AST-102FTSY Viscometer

Page 1: BROOKFIELD AMETEK PROCESS VISCOMETERS AST-102FTSY Viscometer

BROOKFIELD AMETEK PROCESS VISCOMETERS

AST-102FTSY™ Viscometerin-line viscosity control for increased production at lower costs

No moving parts to wear, bind or contact process materials

No narrow gaps to trap product

Simple clean-in-place design complies with 3A standard

Rugged 316L stainless steel construction

Continuous, reliable 4-20 mA, RS232 orRS485 output

Model AST-330SY™ Viscosity Controller (optional)

PLC based single station controller allows operator interface and modification. Various screen options include active bar graph and time adjustable trend history graphs.

Compliant to 3A sanitary standards

TEL 800-628-8139 or 508-946-6200 FAX 508-946-6262 www.brookfieldengineering.com(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 GarchesTél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com

Page 2: BROOKFIELD AMETEK PROCESS VISCOMETERS AST-102FTSY Viscometer

The Model AST-102FTSY fully complies with 3A sanitary standards and has FDA approved components for contact with food. While ideal for food and dairy applications, it can also be used in applications that require improved cleanability.

L05-730-D0516

5"

12"

SIGNAL/TEMP OUTPUT CABLE TO CONTROLLER

ELECTRONICS BOX

2” TRI-CLAMPOUTLET

2-½” TRI-CLAMPINLET

AST-102FTSY Viscosity Sensor Specifications

Measurement Type: Torsionally oscillating probe

Measurement Range: 1 to 3,000 (optional 12,000) cSt using an NIST traceable, Newtonian fluid measured at 25°C

Process Connections: 2½” tri-clamp 3-A design inlet, 2” tri-clamp outlet

Repeatability: ± 1.0% of reading

Wetted Surfaces: 316L stainless steel

Sensor O-Ring: Kalrez for probe, Teflon for chamber housing; both seals are FDA compliant

Temperature (fluid): -20° to 200°C (-4° to 392°F)

Pressure: Up to 200 psi (13.6 bar)

AST-102FTSY Transmitter Specifications

Viscosity Ranges (cSt) (field selectable):

0 to 10 • 0 to 50 • 0 to 100 • 0 to 250 • 0 to 500 • 0 to 1,000 • 0 to 1,500 • 0 to 2,000 • 0 to 3,300 • 0 to 12,000

Maximum Resolution: Analog: ± 0.05% of full scale Digital: ± 0.01 cSt

Analog Output (2): 4—20 mA (non-isolated) CH1 = viscosity CH2 = temperature

Serial Port (2): Port 1 = RS232, simplex, read only, Port 2 = ½ Duplex RS485, Modbus RTU driver

Electronics Packaging: Wall mount, NEMA-4 (IP65), 8” x 8” x 6” (203 x 203 x 152mm)

Ambient Temp Range: 0 to 40°C (32 to 104°F)

Electrical Area Rating: NEMA-4

Interconnecting Cable: 25 ft (7.6m) standard: 50 ft (15.2m) and 75 ft (22.8m) optional

Supply Voltage: 115 VAC, 230 VAC or 24 VDC

AST-102FTSY Diagram

ISO 9001:2008 CERTIFIED

(ES) Equipements Scientifiques SA - Département Bio-tests & Industries - 127 rue de Buzenval BP 26 - 92380 GarchesTél. 01 47 95 99 90 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com