Brochure Filtros Temporales y Canastas

7
FILTROS TEMPORALES STANDARD MATERIAL IS PERFORATED 1/8”DIAMETER HOLES ON 3/16” CENTERS 40%OPEN AREA CARBON STEEL *expanded metal support available REFERENCE STRAINER DESINGS SELECTION AND CONSTRUCTION SECTION FOR OPTIONAL MATERIALS. (Reference bulletin AC303 for wire cloth, perforated and expanded metal availability.) Percent open areas shown are compared to the cross sectional flow area of standard weight pipe. All dimensions are in inches. Standard length designed to fit weld neck flange plus long radius weld elbow. OD is designed to fit inside flange bolt hole circle. Full face is available, add FF to type strainer. ID is designed to fit inside standard weight pipe to 150# and 300# rating, extra strong pipe for 600# rating. Advise pipe wall or schedule for higher pressure ratings. LONGITUD L C TAMAÑO LONGITUD STD. 75% 100% 150% 200% 300% 2 4 - 4 6 8 11 3 6 - 6 9 12 18 4 8 - 8 10 13 20 6 11 - 11 13 18 27 8 12 - 12 17 23 34 10 12 12 14 22 29 44 12 12 12 16 26 35 50 14 14 14 18 27 36 53 16 16 16 21 31 40 60 18 18 18 24 35 46 68 20 20 20 26 39 51 76 24 23 23 31 45 60 90 30 29 29 38 57 76 114 36 33 33 44 66 88 126

Transcript of Brochure Filtros Temporales y Canastas

FILTROS TEMPORALES

STANDARD MATERIAL IS PERFORATED

1/8”DIAMETER HOLES ON 3/16” CENTERS

40%OPEN AREA

CARBON STEEL

*expanded metal support available

REFERENCE STRAINER DESINGS SELECTION AND CONSTRUCTION SECTION FOR OPTIONAL

MATERIALS.

(Reference bulletin AC303 for wire cloth, perforated and expanded metal availability.)

Percent open areas shown are compared to the cross sectional flow area of standard weight

pipe. All dimensions are in inches. Standard length designed to fit weld neck flange plus long

radius weld elbow. OD is designed to fit inside flange bolt hole circle. Full face is available,

add FF to type strainer. ID is designed to fit inside standard weight pipe to 150# and 300#

rating, extra strong pipe for 600# rating. Advise pipe wall or schedule for higher pressure

ratings.

LONGITUD L C

TAMAÑO LONGITUD

STD. 75% 100% 150% 200% 300%

2 4 - 4 6 8 11

3 6 - 6 9 12 18

4 8 - 8 10 13 20

6 11 - 11 13 18 27

8 12 - 12 17 23 34

10 12 12 14 22 29 44

12 12 12 16 26 35 50

14 14 14 18 27 36 53

16 16 16 21 31 40 60

18 18 18 24 35 46 68

20 20 20 26 39 51 76

24 23 23 31 45 60 90

30 29 29 38 57 76 114

36 33 33 44 66 88 126

FILTROS TEMPORALES

Cross bracing can be installed in

both cone and basket strainers to

help prevent collapse

Vibration supports can be

supplied on extra long strainers

to help stabilize the strainer off

of the pipe wall prevent vibration

Both cone and basket strainers

can be inverted to obtain a high

percent of open area in a tight

piping situation

CONES AND BASKETS STRAINERS ASA RING JOINT GASKET

NUMBER (Soft iron cadmium

plated is standard)

DIMENSIONS IN INCHES

ID OD

SIZE

150/300

lb.

RF/FF/RJ

400/600

lb. RF/RJ

900/1500 lb.

RF/RJ

advise pipe

schedule or

flange Dia.

Of bore .

Strainer ID

will be 1/8"

(small sizes)

to 1/2"

(large sizes)

less than

flange bore.

150/300

lb. RF/FF

400

lb.RF

600 lb.

RF

900

lb. RF

1500

lb. RF

300/400/600

lb. RJ

900

lb. RJ

1500

lb. RJ

2500

lb. RJ

3/4 5/8 5/8 2 1/8 2 1/2 2 1/2 2 5/8 2 5/8 R13 R14 R14 R16

1 7/8 7/8 2 1/2 2 3/4 2 3/4 3 3 R16 R16 R16 R18

1 1/4 1 1/8 1 1/8 2 7/8 3 1/8 3 1/8 3 1/4 3 3/8 R18 R18 R18 R21

1 1/2 1 3/8 1 3/8 3 1/4 3 5/8 3 5/8 3 3/4 3 3/4 R20 R20 R20 R23

2 1 7/8 1 7/8 4 4 1/4 4 1/4 5 1/2 5 1/2 R23 R24 R24 R26

2 1/2 2 1/4 1 15/16 4 5/8 5 5 6 1/4 6 3/8 R26 R27 R27 R28

3 2 7/8 2 33/64 5 1/4 5 3/4 5 3/4 6 1/2 6 3/4 R31 R31 R35 R32

4 3 3/4 3 5/8 6 3/4 6 7/8 7 1/2 8 8 1/8 R37 R37 R39 R38

6 5 3/4 5 5/8 8 5/8 9 5/8 10 1/8 11 1/4 11 R45 R45 R46 R47

8 7 1/2 7 3/8 10 3/4

11

3/4 12 3/8 14 13 3/4 R49 R49 R50 R51

10 9 1/2 9 1/4 13 1/8

13

7/8 15 1/2 17 17 R53 R53 R54 R55

12 11 1/2 11 1/8 15 7/8

16

1/4 17 3/4 19 3/8 20 1/4 R57 R57 R58 R60

14 12 7/8

*

17 1/2

18

3/4 19 1/8 20 1/4 - R61 R62 R63 -

16 14 3/4 20

20

7/8 22 22 3/8 - R65 R66 R67 -

18 16 3/4 21 3/8

23

1/8 23 7/8 24 7/8 - R69 R70 R71 -

20 18 3/4 23 5/8

25

1/4 26 5/8 27 1/4 - R73 R74 R75 -

24 22 3/4 28 30 30 7/8 32 3/4 - R77 R78 R79 -

*advise pipe schedule or flange Dia. Of Bore. Strainer ID will be ½” less than flange bore. Larger sizes available.

HOW TO ORDER

1. Quantity

2. Line size

3. Mating flange rating

4. Flange face type

5. Type of strainer required

6. Length required

7. Material of construction

8. Wire mesh & material if required

FILTROS TEMPORALES EN CANASTA

Cross bracing can be installed in

both cone and basket strainers to

help prevent collapse on BP, CP,

BWO, or CWO types.

TYPE BSW OR BSP

Stiffeners on side and top of basket

can be supplied on BP, BW, or BWI

strainers.

Both cone and basket strainers

can be inverted to obtain a high

percent of open area in a tight

piping situation

CONES AND BASKETS STRAINERS ASA RING JOINT GASKET

NUMBER (Soft iron cadmium

plated is standard)

DIMENSIONS IN INCHES

ID OD

SIZE

150/300

lb.

RF/FF/RJ

400/600

lb. RF/RJ

900/1500 lb.

RF/RJ

advise pipe

schedule or

flange Dia.

Of bore .

Strainer ID

will be 1/8"

(small sizes)

to 1/2"

(large sizes)

less than

flange bore.

150/300

lb. RF/FF

400

lb.RF

600 lb.

RF

900

lb. RF

1500

lb. RF

300/400/600

lb. RJ

900

lb. RJ

1500

lb. RJ

2500

lb. RJ

3/4 5/8 5/8 2 1/8 2 1/2 2 1/2 2 5/8 2 5/8 R13 R14 R14 R16

1 7/8 7/8 2 1/2 2 3/4 2 3/4 3 3 R16 R16 R16 R18

1 1/4 1 1/8 1 1/8 2 7/8 3 1/8 3 1/8 3 1/4 3 3/8 R18 R18 R18 R21

1 1/2 1 3/8 1 3/8 3 1/4 3 5/8 3 5/8 3 3/4 3 3/4 R20 R20 R20 R23

2 1 7/8 1 7/8 4 4 1/4 4 1/4 5 1/2 5 1/2 R23 R24 R24 R26

2 1/2 2 1/4 1 15/16 4 5/8 5 5 6 1/4 6 3/8 R26 R27 R27 R28

3 2 7/8 2 33/64 5 1/4 5 3/4 5 3/4 6 1/2 6 3/4 R31 R31 R35 R32

4 3 3/4 3 5/8 6 3/4 6 7/8 7 1/2 8 8 1/8 R37 R37 R39 R38

6 5 3/4 5 5/8 8 5/8 9 5/8 10 1/8 11 1/4 11 R45 R45 R46 R47

8 7 1/2 7 3/8 10 3/4

11

3/4 12 3/8 14 13 3/4 R49 R49 R50 R51

10 9 1/2 9 1/4 13 1/8

13

7/8 15 1/2 17 17 R53 R53 R54 R55

12 11 1/2 11 1/8 15 7/8

16

1/4 17 3/4 19 3/8 20 1/4 R57 R57 R58 R60

14 12 7/8

*

17 1/2

18

3/4 19 1/8 20 1/4 - R61 R62 R63 -

16 14 3/4 20

20

7/8 22 22 3/8 - R65 R66 R67 -

18 16 3/4 21 3/8

23

1/8 23 7/8 24 7/8 - R69 R70 R71 -

20 18 3/4 23 5/8

25

1/4 26 5/8 27 1/4 - R73 R74 R75 -

24 22 3/4 28 30 30 7/8 32 3/4 - R77 R78 R79 -

*advise pipe schedule or flange Dia. Of Bore. Strainer ID will be ½” less than flange bore. Larger sizes available.

HOW TO ORDER

1. Quantity

2. Line size

3. Mating flange rating

4. Flange face type

5. Type of strainer required

6. Length required

7. Material of construction

8. Wire mesh & material if required

FILTROS TEMPORALES PLANOS

HOW TO ORDER

1. Quantity

2. Line size

3. Weamco type

4. Flange rating

5. Perforated material

6. Mesh liner required

STANDARD MATERIAL IS

PERFORATED 1/8” DIAMETER

HOLES ON 3/16” CENTERS

40% OPEN AREA

CARBON STEEL

LONGITUD L C

TAMAÑO I.D.

O.D.

125 Lb. FF 150 Lb. RF

250 Lb. FF 300 Lb. RF

400 Lb. RF

600 Lb. RF

03-abr 1 2 1/8 2 1/2 2 1/2 2 1/2

1 1 1/8 2 1/2 2 3/4 2 3/4 2 3/4

1 1/4 1 3/8 2 7/8 3 1/8 3 1/8 3 1/8

1 1/2 1 5/8 3 1/4 3 5/8 3 5/8 3 5/8

2 2 1/4 4 4 1/4 4 1/4 4 1/4

3 3 1/4 5 1/4 5 3/4 5 3/4 5 3/4

4 4 1/4 6 3/4 7 6 7/8 7 1/2

5 5 1/8 7 1/2 8 3/8 8 1/4 9 3/8

6 6 3/8 8 5/8 9 3/4 9 5/8 10 3/8

8 8 3/8 10 7/8 12 11 7/8 12 1/2

10 10 1/2 13 1/4 14 1/8 14 15 5/8

12 12 1/2 16 16 1/2 16 3/8 18 7/8

14 14 17 1/2 19 18 7/8 19 1/4

16 16 20 21 1/8 21 22 1/8

18 18 21 3/8 23 3/8 23 1/4 24

20 20 23 5/8 25 5/8 25 3/8 26 3/4

24 24 28 30 3/8 30 1/8 31

FILTROS TIPO CANASTA ANSI 150#RF

SLOP TOP BASKET ANGLE BASKET FOR

FOR HORIZONTAL PIPE RUN HORIZONTAL OR VERTICAL PIPE RUN

∗ Based on standard basket perforated 1/8” diameter holes on 3/16” on centers. Open area ratio also Applicable to perforated

patterns 1/4” diameter holes on 3/8” diameter holes on 9/16” centers. Other patterns and wire mesh liners available.

∗ Dimensions BC and AC for the type FT strainer are not firm and can be located at purchasers option within the shell length

or can be offset without changing the basket area

All dimensions are in inches

LINE

SIZE

COMMMON DIMENSIONS

BASKET

SURFACE

AREA (SQ. IN.)

BASKET OPEN

AREA (SQ. IN.)

OPEN AREA

RATIO* FV

WEIGHT

lbs.

FT

WEIGHT

lbs. O.D. F.F. TH BC** AC** DRAIN FV FT FV FT FV FT

2 4 1/2 17 16 9 7 1 44 66 17,6 26,4 524% 787% 60 na

3 6 5/8 20 20 11 9 1 99 140 39,6 56 536% 758% 115 80

4 8 5/8 23 24 14 10 1 1/2 207 245 82,8 98 650% 770% 180 120

6 10 3/4 26 29 17 12 1 1/2 330 366 132 146 457% 505% 280 190

8 12 3/4 30 35 21 14 1 1/2 509 550 204 220 408% 440% 400 260

10 16 34 42 25 17 1 1/2 792 813 317 325 402% 412% 690 460

12 18 37 46 28 18 2 1034 1037 414 415 366% 367% 880 590

14 18 37 53 33 20 2 1232 1247 493 499 358% 362% 930 640

16 24 44 60 36 24 2 1885 2019 754 808 413% 442% 1550 975

18 24 45 65 39 26 2 2073 2170 829 868 355% 387% 1650 1110

20 26 48 71 45 26 2 2512 2569 1005 1028 345% 369% 1930 1790

24 30 56 95 64 31 2 4310 4055 1724 1622 406% 403% 2720 2380

30 36 62 108 71 37 2 5938 5561 2375 2224 353% 342% 3650 3120

FILTROS TIPO CANASTA ANSI 300#RF

SLOP TOP BASKET ANGLE BASKET FOR

FOR HORIZONTAL PIPE RUN HORIZONTAL OR VERTICAL PIPE RUN

∗ Based on standard basket perforated 1/8” diameter holes on 3/16” on centers. Open area ratio also Applicable to perforated

patterns 1/4” diameter holes on 3/8” diameter holes on 9/16” centers. Other patterns and wire mesh liners available.

∗ Dimensions BC and AC for the type FT strainer are not firm and can be located at purchasers option within the shell length

or can be offset without changing the basket area

All dimensions are in inches

LINE

SIZE

COMMMON DIMENSIONS

BASKET

SURFACE

AREA (SQ. IN.)

BASKET OPEN

AREA (SQ. IN.)

OPEN AREA

RATIO* FV

WEIGHT

lbs.

FT

WEIGHT

lbs. O.D. F.F. TH BC** AC** DRAIN FV FT FV FT FV FT

2 4 1/2 17 16 9 7 1 44 66 17,6 26,4 524% 787% 60 na

3 6 5/8 20 20 11 9 1 99 140 39,6 56 536% 758% 115 80

4 8 5/8 23 24 14 10 1 1/2 207 245 82,8 98 650% 770% 180 120

6 10 3/4 24 29 17 12 1 1/2 330 366 132 146 457% 505% 280 190

8 12 3/4 28 35 21 14 1 1/2 509 550 204 220 408% 440% 400 260

10 16 34 42 25 17 1 1/2 792 813 317 325 402% 412% 690 460

12 18 38 46 28 18 2 1034 1037 414 415 366% 367% 880 590

14 18 40 53 33 20 2 1232 1247 493 499 358% 362% 930 640

16 24 44 60 36 24 2 1885 2019 754 808 413% 442% 1550 975

18 24 45 65 39 26 2 2073 2170 829 868 355% 387% 1650 1110

20 26 49 71 45 26 2 2512 2569 1005 1028 345% 369% 1930 1790

24 30 58 95 64 31 2 4310 4055 1724 1622 406% 403% 2720 2380

30 36 62 108 71 37 2 5938 5561 2375 2224 353% 342% 3650 3120

FILTROS TIPO CANASTA ANSI 600#RF

SLOP TOP BASKET ANGLE BASKET FOR

FOR HORIZONTAL PIPE RUN HORIZONTAL OR VERTICAL PIPE RUN

∗ Based on standard basket perforated 1/8” diameter holes on 3/16” on centers. Open area ratio also Applicable to perforated

patterns 1/4” diameter holes on 3/8” diameter holes on 9/16” centers. Other patterns and wire mesh liners available.

∗ Dimensions BC and AC for the type FT strainer are not firm and can be located at purchasers option within the shell length

or can be offset without changing the basket area

All dimensions are in inches

LINE

SIZE

COMMMON DIMENSIONS

BASKET

SURFACE

AREA (SQ. IN.)

BASKET OPEN

AREA (SQ. IN.)

OPEN AREA

RATIO* FV

WEIGHT

lbs.

FT

WEIGHT

lbs. O.D. F.F. TH BC** AC** DRAIN FV FT FV FT FV FT

2 4 1/2 17 16 9 7 1 44 66 17,6 26,4 524% 787% 60 na

3 6 5/8 20 20 11 9 1 99 140 39,6 56 536% 758% 115 80

4 8 5/8 24 24 14 10 1 1/2 207 245 82,8 98 650% 770% 180 120

6 10 3/4 28 29 17 12 1 1/2 330 366 132 146 457% 505% 280 190

8 12 3/4 32 35 21 14 1 1/2 509 550 204 220 408% 440% 400 260

10 16 36 42 25 17 1 1/2 792 813 317 325 402% 412% 690 460

12 18 42 46 28 18 2 1034 1037 414 415 366% 367% 880 590

14 18 44 53 33 20 2 1232 1247 493 499 358% 362% 930 640

16 24 52 60 36 24 2 1885 2019 754 808 413% 442% 1550 975

18 24 54 65 39 26 2 2073 2170 829 868 355% 387% 1650 1110

20 26 58 71 45 26 2 2512 2569 1005 1028 345% 369% 1930 1790

24 30 62 95 64 31 2 4310 4055 1724 1622 406% 403% 2720 2380

30 36 71 108 71 37 2 5938 5561 2375 2224 353% 342% 3650 3120