Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2...

17
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07 User Manual Linksys PAP2 Broadband Phone Service Linhagratuita grupo csdata www.linhagratuita.com.br

Transcript of Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2...

Page 1: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

User Manual Linksys PAP2

Broadband Phone Service

Linhagratuita

grupo csdata www.linhagratuita.com.br

Page 2: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

Please follow the step-by-step guide below to set up your Linksys PAP2 for use with

Linhagratuita Broadband Phone Service.

Before you begin to configure your device:

A. Set your device to factory default:

1. Pick up the phone attached to your Linksys.

2. Dial ****73738#

3. Press 1 to confirm.

4. Hang up the phone.

2

Page 3: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

STEP 1 Connect the Linksys PAP2 to your

Broadband Connection

Use this illustration of the back of the ATA to connect it to your network

1. Phone 1 - Plug your analog telephone cord in here:

2. Ethernet Port - Use an Ethernet cable to connect your PAP2 to your router or

Internet connection:

3. Power connection - Connect the power to your PAP2:

3

Page 4: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

STEP 2 Verify & Configure your IP address

If you have purchased your Linksys PAP2 adaptor from Linhagratuita, skip this

section and proceed to Section B.

If your network utilizes a DHCP Server to assign IP addresses to network devices,or if you are

connecting the PAP2 to a home router such as Linksys or Netgear, please do the following:

A. First you must verify that your PAP2 will acquire an IP adress automatically.

1. Pick up the phone connected to the “Phone 1” port of the PAP2 and enter “* * * *”.

You will then hear a voice say, “Linksys configuration menu.”

2. Press the keys 110 # on your analog phone.

3. Press # to enable DHCP.

4. Press to save your configuration settings. Hang up the phone and wait for a couple

of minutes.

B. Next, you need to verify that your PAP2 has a valid IP address. Be prepared with

pen and paper, and proceed with the following:

1. Pick up the phone connected to Phone 1 of the PAP2 and enter “* * * *”. You will

hear a voice prompt say, “Linksys configuration menu.”

2. Press keys 1 1 0 # on your analog phone. The system will then read back the IP

address of your PAP2. Please write this down.

If the IP is 0.0.0.0, your PAP2 does not have a valid IP address. In this case, you

need to:

1. Hang up the phone, then unplug and replug your PAPA2 power cord.

2. Wait 2 minutes, then check the IP again (see STEP 2).

3. If the automated voice again says your number is still 0.0.0.0, there are three

reasons for this:

a. Your DHCP Server is not assigning an IP address to the PAP2. In this case,

contact your network administrator or ISP for assistance.

b. Your network does not have a DHCP server. In this case, you must

configure your IP manually (See Page 7).

c. You have purchased a Static IP. In this case, configure your IP manually

(See Page 7).

4

Page 5: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

STEP 3 Prepare your device to connect with the

Linhagratuita network

1. Open your configuration page by typing the following address into your web

browser:

https://aaa.bbb.ccc.ddd/admin/advanced

(“aaa.bbb.ccc.ddd. “ represents the IP address of your PAP2).

2. On the configuration page click “Admin Logic,” then click “switch to advanced view.”

3. Next, click the tab link “Line1” and fill in the configuration as shown below. Do not

disturb other default values given on the page.

4. If you want to configure “Line 2” repeat the above configuration with a new

Linhagratuita DID/PIN account.

5. After making the above changes, click “Save Settings.”

6. Close your browser.

1 Inbound-Outbound Configuration with Linhagratuita DID

5

(switch to advanced view) Admin Login

SIP Port 5065

Proxy xxx

Outbound Proxy xxxx

Outbound Proxy yes

Display Name Type Your Name

User ID Type in xxx

Password Type in xxx DID Password

Use Auth ID yes

Auth ID Type in xxx

Prefered Codec G729a

Page 6: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

6

Page 7: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

7

Page 8: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

2: Outbound Dialtone (No IVR) Configuration

8

SIP Port 5065

Proxy xxx

Outbound Proxy xxx

Register no

Make calls without Reg yes

Use Outbound Proxy yes

Display Name Type Your Name

User ID Type in xxx PIN

Use Auth ID yes

Preffered Codec G729a

Page 9: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

9

Page 10: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

10

Page 11: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

3: Outbound IVR Configuration - Requiring user to enter PIN and destination #

11

SIP Port 5065

Proxy xxx

Outbound Proxy xxx

Register no

Display Name Type Your Name

User ID 1234

Use Auth ID yes

Auth ID 1234

Preffered Codec G729a

Dial Plan xxx

Page 12: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

12

Page 13: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

13

Page 14: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

4: Outbound- IVR Configuration - Enter Destination

14

SIP Port 5065

Proxy xxx

Outbound Proxy xxx

Register no

Display Name Type Your Name

User ID Type Your xxx PIN

Use Auth ID yes

Auth ID Type Your xxx PIN

Preffered Codec G729a

Dial Plan xxx

Page 15: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

15

Page 16: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

16

Page 17: Broadband Phone Service › doc › training › pap2manual.pdf · STEP 1 Connect the Linksys PAP2 to your Broadband Connection Use this illustration of the back of the ATA to connect

Linksys PAP2 User Manual csdata the VoIP Company

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031 Web: www.linhagratuita.com.br / E-Mail: [email protected] / CNPJ: 07.196.259/0001-07

STEP 4 Manually Configure Your Static IP

The Linksys adaptor you have received for your Broadband Phone Service is fully configured,

and within minutes you can begin to make your calls. Members using Static IP on their home

network may wish to configure the adaptor with Static IP. If you have otained a Static IP with

your internet service provider (ISP) and wish to configure your adaptor with your Static IP

settings, please follow the instructions below:

1. You will first have to obtain the following information: IP Address, Default Gateway

and Subnet Mask. If you are using a router, please contact the router manufacturer

for instructions for retrieving this information from the router directly. If you have

obtained a Static IP from your internet service provider (ISP) and wish to configure

your adaptor with your Static IP settings, please obtain the information directly from

your ISP.

2. Pick up the telephone receiver of the phone connected to the adaptor and dial * * *

*. You will hear a voice prompt say “Linksys configuration menu.”

3. Press the keys 101# on your analog phone to access the static IP configuration

menu.

4. Press 0 # to disable DHCP, then press 1to save the setting.

5. Press # to access the IP address Menu.

6. Enter your IP address followed by # (i.e., “1 2 3 * 4 5 * 6 7 * 8 9 #” to represent

the IP 123.45.67.89). Press 1 to save the setting.

7. Press 3 # to access the Default Gateway Menu.

8. Enter your Default Gateway (i.e. “1 2 3 * 4 5 * 6 7 * 8 9 #” to represent the

gateway 123.45.67.89. Press to save the setting.

9. Press 2 # to access the subnet mask menu.

10. Enter your Subnet Mask (i.e. “1 2 3 * 4 5 * 6 7 * 8 9 #” to represent the subnet

mask 123.45.67.89. Press to save the setting.

You have now completed the static IP configuration.

To verify that the configuration is correct, please pick up the telephone receiver on the phone

connected to the ATA, and dial * * * * to enter the Linksys configuration menu. Dial 110 # to

hear the adaptor read back the IP address that you have configured. If the IP read aloud is

not the same as the one that you have just entered in, please repeat steps 1 through 10

above once again to ensure that you have entered the correct settings.

17