breaking or rupture an alarm is generated...BEKA presents the worldwide first central lubrication...

2
Progressive distributors with Monitoring of the lubrication lines against breaking or rupture As soon as a lubrication line is damaged, an alarm is generated Safety for lubrication points which have to be provided in any case! Safety for sensitive lube points

Transcript of breaking or rupture an alarm is generated...BEKA presents the worldwide first central lubrication...

  • Progressive distributors with

    Monitoring of the lubrication lines against breaking or rupture

    As soon as a lubrication line is damaged, an alarm is generated

    Safety for lubrication points which have to be provided in any case!

    Safety for sensitive lube points

  • The COMPLETE MONITORING for mobile central lubrication systems

    Users know that central lubrication systems can be monitored in many ways for their operational reliability. The known deficit till now was that a line rupture of the line to the lube point could not be monitored, respectively the costs for monitoring were not justifiable.

    BEKA presents the worldwide first central lubrication system for mobile applications, which monitors line ruptures and which will hence prevent the user from unpleasant surprise.

    Safety for sensitive lube points

    4 monitoredlubrication points

    2 monitoredlubrication points

    Electrical connection

    Connection betweenthe distributors

    Progressive distributor type MX-Fwith line rupture monitoring

    2 monitoredlubrication points

    Line rupture monitoring

    A line break monitoring can be installed at lubrication points

    for which a lubrication is absolutely necessary. The line

    break monitoring controls the pipe lines from the distributor

    outlet to the lubrication point for demolition or rupture.

    Function

    A line break element with pressure indication is

    screwed at the lube point of the distributor

    outlet that has to be monitored.

    A pressure makeup valve with non-return valve

    is screwed directly into the lube point. If pressure

    is reduced due to line break, the pin of the

    pressure indication becomes invisible and the

    electrical circuit is interrupted.

    Pressure indicatorpin is visible = OKpin is invisible = line break

    transparentcap

    Progressive distributors for all applications - also in inox!

    Progressive distributors withline rupture monitoring

    BAIER+KÖPPEL GMBH+Co. KGBEETHOVENSTRASSE 1491257 PEGNITZ/GERMANYwww.beka-lube.de

    1: vorneSeite 2