BRAVO: Superior Design for Handheld Raman
January 28th, 2015 1
Yan Wang, Ph.D.
Presentation at IFPAC Summit PR 2015
2
BRAVO Handheld Raman SpectrometerHighlights at a Glance
January 28th, 2015
LASER class 1M product
SSETM – Sequentially Shifted Excitation (Patented)
Duo LASERTM excitation
IntelliTipTM - automated measuring tip recognition
Intuitive and guided touchscreen operation
Automated batch scan reporting
Inbuilt wavenumber calibration
Robust and precise optics
Wireless data exchange
Complies with 21 CFR Part 11 requirements
3
BRAVO Handheld Raman SpectrometerHardware
January 28th, 2015
Barcode buttonactivates 2D barcode reader
Laser release button
On/off button BRAVO
Battery door
Keypad
Laser on/off button
Measuring tip (bag tip shown)
4
Sequentially shifted excitation – SSETM
Mitigate Fluorescence
January 28th, 2015
J.B. Cooper, M. Abdelkader, K.L. Wise, Appl. Spectros. 67, 973–984 (2013).J.B. Cooper, S. Marshall, R. Jones, M. Abdelkader, K.L. Wise, Appl. Optics. 53, 3333–3340 (2014).
SSETM (patented) method generates Raman spectra in true spectral space does not require generation (and subsequent reconstruction) of derivative spectra (SERDS) results in improved signal-to-noise ratio compared to traditional fluorescence rejection methods while
providing instrument-limited bandwidth resolution
50010001500200025003000Raman Shift / cm-1
Ram
an I
nte
nsi
ty
-Lactose monohydrate
No impact of Fluorescence
5
Sequentially shifted excitation – SSETM
Mitigate Fluorescence
January 28th, 2015
40060080010001200140016001800Raman shift cm-1
Ram
an In
ten
sity
Talc in PE
BRAVOconvenient dispersive Raman spectrometer
6
Duo LASERTM Access the CH stretching region
January 28th, 2015
50010001500200025003000Raman Shift / cm-1
Ram
an I
nte
nsi
ty
4-Acetamidophenol
FT-Raman (spectral resolution 8cm-1)
BRAVO
Access to the CH stretching range avoids erroneous verification/identification
Examples:
• Discrimination between different polymorphs of a drug
• Contamination of sample with e.g. cyanide (cannot be observed if the Raman shifts ends at 1800cm -1)
7
IntelliTipTM
Always use the proper measuring tip
January 28th, 2015
Inner Spacer
Bag Cap
IntelliTipTM
The locking mechanism design guarantees
quick and highly reproducible connection/
disconnection of measuring tips.
ID chips prevent to release the Laser unless a
tip is connected.
Even more, if a measuring tip is defined in the
library for a chemical material, BRAVO will
inform the user which measurement tip needs
to be used for the verification.
8
Intuitive, gesture-based touch screen GUISpeed up your workflow
January 28th, 2015
Validity of Performance Qualification (PQ) and Operational Qualification (OQ)
Drop down menu lists messages, warnings, etc. indicated by the envelope icon on the upper left
Network connectivity
Battery lifetime
General Information
9
Intuitive, gesture-based touch screen GUILogin Screen
January 28th, 2015
Enter Username:
hit any letter on the onscreen keyboard (OSK) that is contained in the name you like to enter
Example: hit A and get a list of all names containing A
select the proper entry, or scroll down to find the proper entry, or hit letter next to A to shorten the selection list
Enter Password:
Enter password on OSK
The approach described above will not work!
10
Intuitive, gesture-based touch screen GUIMain Screen
January 28th, 2015
Sample Verification will guide through the verification procedure and ends up with an
Accepted / Rejected information
Acquire Materials can be used to acquire spectra for building a library
Review Results allows to review formerly measured spectra still being stored on the
BRAVO
Library Management allows to select/deselect library for verification
Settings allows for basic settings like date, time, LCD brightness, etc. (availability depends on user rights)
11
Intuitive, gesture-based touch screen GUISample Verification Workflow
January 28th, 2015
Material Name:Describes the name of a chemical compound to be analyzed in its packaging (example: Talc in PE bag, Talc in vial), this is a required entry
Batch/Lot# and Container# can be filled in but are not mandatory for proceeding
All information can be entered via the OSK in the above explained manner
or by using the 2D barcode reader which can either be activated on the touchscreen by touching the following icon
or by pressing the barcode button on the BRAVO keypad
Start sample verification workflow by touching sample verification icon
Operator
12
Intuitive, gesture-based touch screen GUISample Verification Workflow
January 28th, 2015
Once the sample information are completed
Touch the Laser icon
or swipe with the finger in direction of the arrows
Operator
13
Intuitive, gesture-based touch screen GUISample Verification Workflow
January 28th, 2015
IntelliTipTM now tells which measuring tip needs to be used
To start the verification:
touch the Press to Start icon
or press Laser release button on the BRAVO keypad
Place Vial into Sample Holder
Operator
14
Intuitive, gesture-based touch screen GUISample Verification Workflow
January 28th, 2015
Results
it’s clearly visible whether the verification was Accepted or Rejected
derived spectrum and library spectrum can be viewed on Results screen
touching the barcode icon brings back to the first screen
in case of entries on the first screen differ by Container # only, a message will appear stating how many containers had been measured already
Operator
Batch Scan Touching this icon brings back to the first
screen. Material Name and Batch/Lot # are already filled in.
Results screen