BouMatic GMI+ version 6.5

9
Technical Bulletin BouMatic Gascoigne Melotte Sprl 31, Rue Jules Melotte 2 November 2007, Bulletin #BGM-50 BouMatic GMI+ version 6.5 Important note: This technical bulletin replaces TI1025 and is additional to Technical Manuals D105072 (NL), D105073 (DE), D105074 (EN) and D105075 (FR) Attachments: GMI+ Calibration form (page 8), GMI+ Settings form (page 9) Partnumber Issue Description D492604 6.5 GMI+ 6.5 assembly (Sensor + bracket + Control box/Keyboard) 10000005 5.0/6.5 PCB GMI+ 1. Description This Technical bulletin introduces the new hard- and firmware release 6.5 of the GMI+ milk yield indicator. As from now, all GMI+ milk yield indicators will be equipped with version 6.5 firmware. Version 5.7 is not available anymore. Version 5.7 PCB’s and version 6.5 PCB’s can be mixed within one installation, unless the customer requires the new 6.5 features (See chapter 7). This new version includes: New keyboard foil, in BouMatic style Integrated Conductivity measurement, to indicate possible cell count problems Improved handling of short circuits and bad and open connections on electrical outputs New keyboard functions: - Standby mode of the PCB (for service purposes) - Forced Cleaning mode 2. New keyboard foil From this version, all new GMI+ assemblies will be delivered in the new BouMatic graphics style. 4350 Remicourt - Belgium T +32 (0) 19 54 42 66 F +32 (0) 19 54 55 44 E [email protected] VAT BE 866 755 277 TVA FR 20 482 608 403 FORTIS 001-4391486-81 IBAN BE 36 001439148681 SWIFT GEBABEBB www.boumatic.com

description

BouMatic GMI+ version 6.5 Technical Bulletin

Transcript of BouMatic GMI+ version 6.5

Page 1: BouMatic GMI+ version 6.5

Technical Bulletin

BouMatic Gascoigne Melotte Sprl

31, Rue Jules Melotte

2 November 2007, Bulletin #BGM-50

BouMatic GMI+ version 6.5

Important note: This technical bulletin replaces TI1025 and is additional to Technical Manuals D105072 (NL), D105073 (DE), D105074 (EN) and D105075 (FR)

Attachments: GMI+ Calibration form (page 8), GMI+ Settings form (page 9)

Partnumber Issue Description D492604 6.5 GMI+ 6.5 assembly (Sensor + bracket + Control box/Keyboard) 10000005 5.0/6.5 PCB GMI+

1. Description This Technical bulletin introduces the new hard- and firmware release 6.5 of the GMI+ milk yield indicator. As from now, all GMI+ milk yield indicators will be equipped with version 6.5 firmware. Version 5.7 is not available anymore. Version 5.7 PCB’s and version 6.5 PCB’s can be mixed within one installation, unless the customer requires the new 6.5 features (See chapter 7). This new version includes: • New keyboard foil, in BouMatic style • Integrated Conductivity measurement, to indicate possible cell count problems • Improved handling of short circuits and bad and open connections on electrical outputs • New keyboard functions:

- Standby mode of the PCB (for service purposes) - Forced Cleaning mode

2. New keyboard foil From this version, all new GMI+ assemblies will be delivered in the new BouMatic graphics style.

4350 Remicourt - Belgium T +32 (0) 19 54 42 66 F +32 (0) 19 54 55 44 E [email protected]

VAT BE 866 755 277 TVA FR 20 482 608 403 FORTIS 001-4391486-81 IBAN BE 36 001439148681 SWIFT GEBABEBB www.boumatic.com

Page 2: BouMatic GMI+ version 6.5

3. System settings To configure the GMI+ unit, follow the next procedure:

• In milking mode (detached), press the buttons and together for 3 seconds until

dCAC appears on the display.

• Press or to scroll through the settings.

• Press to access Edit-mode.

• Press or to change the setting to the desired value.

• Press to leave the Edit-mode and return back to the settings.

• When all settings are completed, press or until END appears on the display.

• Press to return to normal milking mode. • Restart the PCB by using the Standby procedure (See point 7.2), or power off/power on the PCB.

PCB must be restarted to accept the new values (see line above). Setting Description Default Limit Measuring

Unit

dCAC Power supply mode (0=Smooth DC, 1=AC or Unregulated DC)*

0 0-1 N/A

EUCC Short circuit detection: 0 = Switch off the corresponding output completely 1 = Switch off the corresponding output and restart after time T-CC (not recommended)

0 0-1 N/A

T-CC Time to reset a short circuit detection (If EUCC=1) 300 20-6000 msec. t-A Blinking interval between actual milk yield and

actual milking time 3 0-200 sec.

uNiS Unit of measuring (0=Kg, 1=Lbs) 0 0-1 N/A tn C Initial delay, automatic detach will not take place 90 0-250 sec. EdGE Detach level 0.30 0.01-2.00 L/min. CrM Detach delay. Unit detaches when milk flow is

below detach level for this amount of seconds 8 0-99 sec.

diSC Vacuum attach delay. Time between initiating the cluster and opening shut-off valve

1.5 0.0-9.9 sec.

C1 Cluster venting delay. Time between closing shut-off valve and operating cylinder

1.5 0.0-9.9 sec.

C2 Milk sweep delay. Time after detach until milk sweep takes place

15 0-99 sec.

C3 Milk sweep open time. 0 = Milk sweep disabled 1.5 0.0-9.9 sec. t-rA Re-Attach delay. When re-attach within this time,

the milk yield will be added to the actual yield 00.00 00.00-

10.00 min.,sec.

t1 Pulsation delay in Cleaning mode. When switch to Cleaning Mode, pulsation starts after this time

0 0-200 sec.

t2 Pulsation duration in Cleaning mode. After this time all solenoids become powerless

0 0-200 min.

S-G Sheep & Goat setting (1) or Cow (0). In Sheep & Goat mode, 1 extra digit is displayed (0,01)

0 0-1 N/A

SEt0 Calibration value milk flow sensor When indication is too low, increase SEt0 When indication is too high, decrease SEt0 1 point corresponds to approximately 0.3 Kg

21 0-30 N/A

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 2 of 9

Page 3: BouMatic GMI+ version 6.5

o-F Pulsation offset enabled (1) or disabled (0) 1 0-1 N/A C PM Pulsation rate in Cleaning mode 40 0-255 pulses/min. C E1 Pulsation ratio front in Cleaning mode 50 0-100 % C E2 Pulsation ratio rear in Cleaning mode 50 0-100 % M PM Pulsation rate in Milking mode 60 0-255 pulses/min. M E1 Pulsation ratio front in Milking mode 60 0-100 % M E2 Pulsation ratio rear in Milking mode 60 0-100 % iEnA Conductivity measurement enabled (1) or disabled

(0) 0 0-1 N/A

iEdG Cell count attention level (10=100000, 20=200000 etc.)

30 0-60 x 10000 somatic cells

idEL First milk not considered for conductivity measurement

3 (300 gram)

0-20 x 100 g

dEF Reset GMI+ to default settings (1) 0 0-1 N/A * When using an Unregulated Power supply, like the GM 14 VDC Transformer D262623 (12A) or

D494073 (3A), setting dCAC must be 1. * When using a smooth (switch-mode) power supply, like D390748 (13VDC, 20A), or in a Parlour

Support Unit, setting dCAC must be 0. 4. Power supply • Although the GMI+ system can work with several types of power supplies, BouMatic strongly

recommends the BGM 13VDC/20A switch-mode power supply (D390748). See drawing below. • Adjust the 13VDC/20A power supply to 14,0 VDC. • When using a switch-mode power supply, setting dCAC must be set to 0. • Maximum 12 GMI+ units can be powered by one 13VDC/20A power supply. • In case of more than 1 power supply: connect the 0VDC outputs of all power supplies with each

other (1x 2.5 mm2 blue). • Connect 0VDC to Earth (1x 2.5 mm2 blue).

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 3 of 9

Page 4: BouMatic GMI+ version 6.5

5. Wiring Diagram General notes: • The GMI+ system requires a good mains earth connection (< 6 Ohm). • Keep cables as short as possible. • Avoid tapping blocks to lengthen cables. • To avoid stray voltages, all metal parts in the parlour have to be grounded (earth). • Avoid any ragged connections. Slider connectors inside TL pulsators and Isolator TL’s must be

tightened precisely.

. Cable between GMI+ and Cylinder (3 x 0.75 mm

2).

. Power cable (3 x 0.75 mm2).

Maximum length 4 meter. Create a ‘star’ connection to cluster several

power cables into 1 connection box.

. Main Power cable (3 x 2.5 mm2). Use 2 x (3 x 2.5 mm

2) cables to wire the GMI+ units from the power

supply (1 down each side of the parlour, maximum 8 GMI+ units per cable). Maximum length 25 meter.

. Milk/Clean Signal (3 x 0.75 mm2).

Use 2 of the 3 cores.

. Sensor cable (2 x 0.34 mm2, shielded).

. Pulsation. Cable between GMI+ and Pulsator (3 x 0.75 mm2).

. Vacuum shut-off. Cable between GMI+ and Isolator TL (2 x 0.75 mm2).

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 4 of 9

Page 5: BouMatic GMI+ version 6.5

6. Connection Diagram

Milk flow sensor

GM Cylinder: Quick start E6 Solenoid CE6

E5 IsolatorTL CE5 (DV-5)

Fuse SMD 3,15 Amp P/N: D269580

CE4 Not in E4 Use

KEYBOARD CONNECTOR

CE1 Common E2 REAR Pulsator 12/24 VOLT E1 FRONT

Power In (14 VDC): Milk/Clean Power + Power -

Comm. IN. From previous GMI+ or PC interface (N/A)

Shield

White

Brown Comm. OUT. To next GMI+ (N/A)

Termination. Close on end of comm. line (N/A)

CE3 Not in E3 Use

White

Brown

Shield

Brown +

+

Green +

White -

-

White -

Brown -

GreenGreen

Brown +

White -

Brown

White

J2: Not in use

J1: Open = V6.5 Close = V5.0

• For vacuum shut-off, 1 Isolator TL (D494170) is used to operate the DV5 valves (D480080) of 2 stalls. 1 side of an Isolator TL is connected to output E5 of a GMI+. The other side of the Isolator TL is connected to output E5 of the next stall. So a 2x6 installation requires only 6 Isolator TL’s.

7. New features: 7.1 Conductivity measurement • This version of GMI+ is equipped with conductivity measurement to give an attention based on the

somatic cell count of the measured milk. Be aware that it’s just a rough indication. BGM doesn’t accept any responsibility for eventually not showing a cell count attention on cows which have a high somatic cell count.

• If the GMI+ system records a high conductivity value (> iEdG) for a short period of time, the

display shows SCC1, alternating with the milk yield. • If the GMI+ system records a high conductivity value (> iEdG) for a long period of time, the

display shows SCC2, alternating with the milk yield. • Setting iEnA enables (1) or disables (0) conductivity measurement.

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 5 of 9

Page 6: BouMatic GMI+ version 6.5

• Setting iEdG sets the attention threshold level. The attention level can be set in between 100000 and 600000 somatic cells (approximately) in steps of 10000 cells. Default is 300000.

• Setting idEL sets the first milk not considered for conductivity measurement. Default is 0.3 Kg. Conductivity measurement starts above this milk yield.

7.2 Standby mode

• When in milking mode (detached), the GMI+ can be put in Standby mode by pressing the button for 2 seconds. All outputs become powerless and the display switches off.

• Press the button shortly to restart the PCB. It shows the version number (U6.5) followed by OK. After 2 seconds the PCB is in milking mode. Ready to use.

7.3 Forced Cleaning mode

• When in Pre-Clean mode (display shows PrCL), the GMI+ can be put into real Cleaning mode by

pressing the button for 1 second until 00.00 appears. Release the button and CLn will appear. This option can be used in emergency situations when the milk/clean switch or wash programmer is not working correctly.

• Press the button shortly to turn the PCB back into milking mode. Ready to use. 8. Existing features (Similar to version 5.7) 8.1 Pulsation control • This version of GMI+ can operate a GM Lectron TL pulsator (or any other 12VDC pulsator). • Adjustable pulsation rate (M PM) and ratio (M E1, M E2). • Automatic Offset calculation (o-F = 1), for optimal pulsation.

Offset (o-F = 1)

Front

Rear

Front

Rear

Offset (o-F = 0)

8.2 Central Milking / Cleaning mode • This version of GMI+ can be put into Milking and Cleaning mode by a single switch, or by a wash

programmer like the Aquastar (CN9/1 – CN9/2).

• The display shows CLn when the GMI+ is in Cleaning mode. • When switch to Cleaning mode, pulsation starts after ‘Pulsation delay in Cleaning mode’ seconds.

(t1). • In Cleaning mode, pulsation runs at 40 pulses per minute (C PM) with a 50/50 ratio (C E1, C E2). • In Cleaning mode, pulsation stops after ‘Pulsation duration in Cleaning mode’ minutes. (t2). At the

same moment, all electric outputs on the PCB become powerless.

Front

Rear

Cleaning mode

Shut-off valve

t1 (sec)

diSC (sec)

t2 (sec)

8.3 Milk Sweep • Milk Sweep releases the remaining milk from the long milk tube after detaching, by opening the

shut-off valve for a short time. • Default waiting time between detaching and Milk Sweep is 15 seconds. (C2 = 15). • Default open time of the shut-off valve is 1,5 seconds. (C3 = 1,5). • To disable the Milk Sweep feature, setting C3 must be set to 0.

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 6 of 9

Page 7: BouMatic GMI+ version 6.5

Cylinder

Shut-off valve

Milk Sweep delay (C2)

8.4 Improved Re-attachment procedure • When setting t-rA is set to 30 seconds or more, after re-attachment within this time the milk yield

is added to the actual yield. This is useful when there is a kick-off or cluster fall-off. • The initial delay after re-attachment within time t-rA is 30 seconds (fixed). 8.5 Improved Pre-Clean procedure

• When pressing the button for 3 seconds, the cylinder releases the cluster without vacuum and the cluster can be placed into the wash-jetters. This can be done even when other stalls are

still milking. The display shows PrCL when the GMI+ is in Pre-clean mode. 8.6 Improved Auto/Manual mode

• The function of the left LED has changed: When the GMi+ is in automatic mode the LED is OFF during the initial delay.

• After the initial delay (setting tN C) the LED blinks.

• When pressing the button, the GMi+ switches to manual mode and the LED turns ON. 9. Compatibility with Version 5.0, 5.7 and 6.0 • The PCB of the GMI+ 6.5 is compatible with GMI+ 5.0. By just placing a jumper (dealer supplied)

on J1, the PCB is in 5.0 mode. An open jumper means the PCB is in 6.5 mode. • After changing from 6.5 into 5.0 or from 5.0 back into 6.5, the settings have to be reset to default

values. Use the dEF setting (dEF = 1).

• There is one major difference with an old 5.0 PCB: The new PCB shows CLn when in cleaning mode.

• The new PCB is also compatible with versions 5.7 and 6.0. PCB’s versions 5.7, 6.0 and 6.5 can work together in the same parlour, although some settings are not the same. (EUCC ,T-CC, iEnA, iEdG and iDel)

• Some 5.7 PCB’s already contain the Conductivity Measurement. If the settings iEnA, IEdG and idEL are accessible, conductivity measurement can be activated.

• The partnumber of a spare PCB 5.0/6.5 remains the same: 10000005. BouMatic Gascoigne Melotte Sprl Research and Development

Detach

Cluster Venting delay (C1) Milk Sweep open time (C3)

Technical Bulletin #BGM-50 GMI+ version 6.5 Hardware and Firmware.doc page 7 of 9

Page 8: BouMatic GMI+ version 6.5

GMI+ Calibration Form

Dealer Technician

Customer Date

Address Parlour type

Town Parlour size

Phone no. GMI+ version

Milk yield Difference Milk yield Difference

Nr. Display Scales Kg %

SEt0 Remarks Nr. Display Scales Kg %

Set0 Remarks

Page 9: BouMatic GMI+ version 6.5

GMI+ Settings Form

Dealer Technician

Customer Date

Address Parlour type

Town Parlour size

Phone no. GMI+ version

Setting Description Default

value Actual value

New value

New value

Limit Unit

dCAC Power supply mode 0 0-1 N/A EUCC Short circuit detection: 0 0-1 N/A T-CC Time to reset a short circuit

detection (If EUCC=1) 300 20-6000 msec.

t-A Blinking interval between actual milk yield and actual milking time

3 0-200 sec.

uNiS Unit of measuring (0=Kg, 1=Lbs) 0 0-1 N/A tn C Initial delay 90 0-250 sec. EdGE Detach level 0.30 0.01-2.00 L/min. CrM Detach delay 8 0-99 sec. diSC Vacuum attach delay 1.5 0.0-9.9 sec. C1 Cluster venting delay 1.5 0.0-9.9 sec. C2 Milk sweep delay 15 0-99 sec. C3 Milk sweep open time 1.5 0.0-9.9 sec. t-rA Re-Attach delay 00.00 00.00-

10.00 min.,sec.

t1 Pulsation delay in Cleaning mode 0 0-200 sec. t2 Pulsation duration in Cleaning

mode 0 0-200 min.

S-G Sheep & Goat setting 0 0-1 N/A SEt0 Calibration value milk flow sensor 21 0-30 N/A o-F Pulsation offset enabled (1) or

disabled (0) 1 0-1 N/A

C PM Pulsation rate in Cleaning mode 40 0-255 pulses/ min.

C E1 Pulsation ratio front in Cleaning mode

50 0-100 %

C E2 Pulsation ratio rear in Cleaning mode

50 0-100 %

M PM Pulsation rate in Milking mode 60 0-255 pulses/ min.

M E1 Pulsation ratio front in Milking mode

60 0-100 %

M E2 Pulsation ratio rear in Milking mode

60 0-100 %

iEnA Conductivity measurement enabled (1) or disabled (0)

0 0-1 N/A

iEdG Cell count attention level 30 0-60 x 10000 somatic

cells idEL First milk not considered for

conductivity measurement 3 (300 gram)

0-20 x 100 g

dEF Reset GMI+ to default settings 0 0-1 N/A