BOQ_Puna-I as Per Aug, 2010

27
400 kV MHEP Lines Page 1 of 27 Summary SUMMARY OF COST Price Comparison with Puna-I Rates (All prices in Nu./Rs.) Sl# Description As per Puna-I (2010) M/s L&T Limited M/S Jyoti Structurtes Ltd. Amount Amount Amount 1.0 Total for Schedule 1 - Supply portion 2,001,357,307.00 2,928,414,818.00 2,997,275,463.75 2,652,739,021.00 2.0 Total for Schedule 2 - Erection Portion 2,649,540,823.00 3,556,510,283.00 2,485,117,871.99 3,357,079,044.00 3.0 Total for Schedule 3 - Type Testing 4,231,599.00 8,269,174.00 8,023,143.14 4,690,322.00 GRAND TOTAL 4,655,129,729.00 6,493,194,275.00 5,490,416,478.88 6,014,508,387.00 1838776242.955 837923351.22 1396538918.7 Figure in words : 6,493,905,971.96 5,493,053,080.22 6,051,668,647.70 40% 18% 30% Date : Signature of Bidder:_______________ Name of Bidder :__________________ Place : Seal of the Company :______________ SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each M/S Kalpataru Power Transmission Ltd.

description

Bill of Quantities P-I

Transcript of BOQ_Puna-I as Per Aug, 2010

Page 1: BOQ_Puna-I as Per Aug, 2010

400 kV MHEP Lines Page 1 of 27 Summary

SUMMARY OF COST

Price Comparison with Puna-I Rates

(All prices in Nu./Rs.)

Sl# DescriptionAs per Puna-I (2010) M/s L&T Limited M/S Jyoti Structurtes Ltd.

Amount Amount Amount

1.0 Total for Schedule 1 - Supply portion 2,001,357,307.00 2,928,414,818.00 2,997,275,463.75 2,652,739,021.00

2.0 Total for Schedule 2 - Erection Portion 2,649,540,823.00 3,556,510,283.00 2,485,117,871.99 3,357,079,044.00

3.0 Total for Schedule 3 - Type Testing 4,231,599.00 8,269,174.00 8,023,143.14 4,690,322.00

GRAND TOTAL 4,655,129,729.00 6,493,194,275.00 5,490,416,478.88 6,014,508,387.00

1838776242.955 837923351.22 1396538918.7Figure in words : 6,493,905,971.96 5,493,053,080.22 6,051,668,647.70

40% 18% 30%

Date : Signature of Bidder:_______________

Name of Bidder :__________________

Place : Seal of the Company :______________

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING)

- Approx. 80 km each

M/S Kalpataru Power Transmission Ltd.

Page 2: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 2 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

1.0 Towers

1.1

i) High Tensile Steel MT 7,926 70,443.00 78,453.00 621,818,478.00 ii ) Mild Steel MT 5,762 65,003.00 73,013.00 420,700,906.00

1.2 ##

i) High Tensile Steel MT 454 69,525.00 77,535.00 35,200,890.00 ii ) Mild Steel MT 41 64,085.00 72,095.00 2,955,895.00

1.3 ##

MT 598 77,133.00 81,584.00 48,787,232.00

ii) Hex.Anti theft Bolts & Nuts MT 64 130,533.00 134,983.00 8,638,912.00

1.4 MT 8 77,133.00 81,584.00 652,672.00

2.0 Supply of earthing of towers ##

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

Fabrication, galvanising and supply of various types of towers, & its body / leg (equal & unequal) extensions (complete) excluding stubs and bolts & nuts but including hangers, D-shackles, pack washer etc. (payment shall be released for identified MT for complete tower)

Fabrication, galvanising & supply of stubs for various types of towers with pack washers excluding supply of bolts & nuts

Supply of Bolts & Nuts for towers except for stubs

i) Hexagonal Bolts & Nuts including Step Bolts

Supply of Hex. Bolts & Nuts for stubs including plain washers

Page 3: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 3 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

i) Pipe Type Nos. 40 2,373.00 2,670.00 106,800.00ii) Counterpoise Type ##

a) 120 meter length Nos. 393 6,942.00 7,796.00 3,063,828.00b) 280 meter length Nos. 16 16,197.00 18,191.00 291,056.00

3.0 ##

i) Danger Plate Nos. 449 237.00 261.00 117,189.00ii) Number Plate Nos. 449 237.00 261.00 117,189.00

iii) Phase Plate (Set of three) Sets 898 237.00 261.00 234,378.00iv) Circuit Plate (Set of two) Sets 449 237.00 261.00 117,189.00v) Anti-Climbing Device Nos. 449 7,120.00 7,832.00 3,516,568.00

4.0 ##

i) Span markers Nos. 40 5,933.00 6,526.00 261,040.00

ii) ##

a) 1 Medium+2 low intensity Sets 25 338,199.00 372,020.00 9,300,500.00

5.0 ##

5.1 Conductor ##i) ACSR MOOSE conductor km 1,632 225,466.00 234,889.00 383,338,848.00

ii) AACSR MOOSE conductor km 317 232,586.00 242,009.00 76,716,853.005.2 Earthwire ##

i) GS Earthwire-7/3.66 mm km 136 33,820.00 37,380.00 5,083,680.00ii) GS Earthwire-7/4.5 mm km 27 52,213.00 55,772.00 1,505,844.00

Supply of the following tower accessories

Supply of following items for aviation requirements

Obstrcution lights( to be provided as per IS: 5613)

Design, manufacture and supply of following line material items

Page 4: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 4 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

5.3 Standard disc Insulators ##a) 120 KN No. 12,792 534.00 640.00 8,186,880.00b) 160 KN No. 273,000 652.00 770.00 210,210,000.00

5.4 Hardware Fittings ##

i) Sets 444 4,776.00 5,205.00 2,311,020.00

ii) Sets 48 8,698.00 9,481.00 455,088.00

iii) Sets 5,100 14,109.00 15,378.00 78,427,800.00

iv) Sets 240 23,899.00 26,050.00 6,252,000.00

5.5 ##

i) Nos. 1,171 708.00 772.00 904,012.00

ii) Nos. 198 828.00 903.00 178,794.00

iii) Nos. 90 208.00 227.00 20,430.00

Single Suspension Pilot Insulator String (suitable for 1 x 26, 120 KN Disc Insulators)

Single Tension Insulator String (suitable for 1 x 26, 120 KN Disc Insulators)

Double Tension Insulator String (suitable for 2 x 25, 160 KN Disc Insulators)

Triple Tension Insulator String (suitable for 3 x 25, 160 KN Disc Insulators)

Accessories for Conductor & Earthwire

Mid Span Compression Joint for ACSR MOOSE conductor

Mid Span Compression Joint for AACSR MOOSE conductor

Mid Span Compression Joint for 7/3.66 mm GS Earthwire

Page 5: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 5 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

iv) Nos. 15 237.00 258.00 3,870.00

v) Nos. 356 261.00 285.00 101,460.00

vi) Nos. 60 312.00 341.00 20,460.00

vii) Nos. 121 1,272.00 1,386.00 167,706.00

viii) Nos. 875 348.00 379.00 331,625.00

ix) Nos. 30 348.00 379.00 11,370.00

x) Nos. 20,988 670.00 731.00 15,342,228.00

xi) Nos. 715 670.00 731.00 522,665.00

xii) Nos. 1,749 311.00 340.00 594,660.00

xiii) Nos. 60 311.00 340.00 20,400.00

xiv) Nos. 18,894 650.00 709.00 13,395,846.00

xv) Nos. 894 650.00 709.00 633,846.00

Mid Span Compression Joint for 7/4.5 mm GS Earthwire

Repair Sleeve for ACSR MOOSE conductor

Repair Sleeve for AACSR MOOSE conductor

T-Connector for ACSR MOOSE conductor

Flexible Copper Bond for 7/3.66 mm GS Earthwire

Flexible Copper Bond for 7/4.5 mm GS Earthwire

Vibration Damper for ACSR MOOSE conductor

Vibration Damper for AACSR MOOSE conductor

Vibration Damper for 7/3.66 mm GS Earthwire

Vibration Damper for 7/4.5 mm GS Earthwire

Bundle Spacer for twin ACSR MOOSE Conductor

Bundle Spacer for twin AACSR MOOSE Conductor

Page 6: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 6 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

xvi) Nos. 7,645 374.00 408.00 3,119,160.00

xvii) Nos. 268 374.00 408.00 109,344.00

xviii) Nos. 875 611.00 665.00 581,875.00

xix) Nos. 30 650.00 709.00 21,270.00

6.0 ##

KM 163 150,030.00 157,150.00 25,615,450.00

Rigid Spacer for jumper for twin ACSR MOOSE Conductor

Rigid Spacer for jumper for twin AACSR MOOSE Conductor

Tension Clamp for 7/3.66 mm GS Earthwire

Tension Clamp for 7/4.5 mm GS Earthwire

Design, manufacture and supply of following OPGW Fibre optic Cable & Accessories

a) OPGW Fibre Optic Cable - 24 Fibre (DWSM) including Approch Fibre Cable:One set of installation hardware shall contain all installation hardware fittings as may be required for 1Km Fibre optic cabling

Page 7: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 7 of 27 Schedule 1

SCHEDULE 1 - SUPPLY PORTION(All prices in Nu./Rs.)

Sl# Description Unit Qty.

Puna-I Rates

Unit Price

Total FAS PriceEx-work Price FAS Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

Set 163 57,731.00 62,927.00 10,257,101.00

7.0 No. 8 118,693.00 129,375.00 1,035,000.00

TOTAL FOR SCHEDULE 1 2,001,357,307.00

Date : Signature of Bidder:_______________

Name of Bidder :__________________

Place : Seal of the Company :______________

b) Installation Hardware: OPGW Fibre Cable installation hardware set including all cable fittings & accessories like suspension clamps, tension clams, vibration dampers, earthing clamps, down lead clamps, in-line splice enclosers etc. for item a) above.

Supply of Fibre Optic Distribution Panel (FODP) including Pigtails for 24 Fibre type: Indoor type, rock mounted including pigtailed FCPC coupling

Page 8: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 8 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

1.0 Access, Clearing & Survey

i) kms 160 46,221.00 7,395,360.00

ii) Check survey kms 160 24,601.00 3,936,160.002.0 Detailed Soil Investigation

i) Loc. 80 29,819.00 2,385,520.00

ii) Fissured Rock Loc. 80 44,729.00 3,578,320.00iii) Hard Rock Loc. 17 74,551.00 1,267,367.003.0 Benching

i) Cum 179600 210.00 37,716,000.00###

ii) Fissured Rock Cum 179600 573.00 102,910,800.00###iii) Hard Rock Cum 89800 892.00 80,101,600.00###

4.0 ###

4.1 Excavation in various types of soils 0.00i) Dry Soil Cum 61865 372.00 23,013,780.00ii) Wet Soil Cum 31885 432.00 13,774,320.00

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

Detailed Survey including route alignment, line of sight clearance (bush & tree cutting), profiling & tower spotting, submission of drawings

All kinds of soil except fissured rock & hard rock

All kind of soil except fissured rock & hard rock

Work Associated with Tower Foundations for various types of Tower

Page 9: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 9 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

iii) Dry Fissured Rock Cum 55792 925.00 51,607,600.00iv) Hard Rock Cum 5364 1,043.00 5,594,652.00

4.2

i) M20 Concrete Nominal Mix 1:1.5:3 Cum 25500 29,075.00 741,412,500.00

ii) Cum 2469 27,583.00 68,102,427.00

4.3 MT 2940 70,822.00 208,216,680.00

4.4 MT 503 8,945.00 4,499,335.00

5.0 MT 14350 17,891.00 256,735,850.00

6.0

Concreting (including all associated works related to foundation not covered in 4.1 & 4.3)

M10 Lean Concrete Nominal Mix 1:3:6

Supply and Placement of reinforcement steel

Installation of Stubs including bolts and nuts

Erection of various type of towers, tower parts and its body / leg (equal/ unequal) extensions (complete) including bolts & nuts, step bolts, hangers, D Shackles etc.including tack welding and supply & application of Zinc rich primer and two coats of enamel paints

Protection of tower footings ( installation)

Page 10: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 10 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

i) Cum 72475 7,655.00 554,796,125.00

ii) Cum 23614 6,379.00 150,633,706.00

iii) Cum 36207 255.00 9,232,785.00

iv) Cum 10864 17,224.00 187,121,536.00

7.0 Installation of earthing of towers 0.00i) Pipe Type Nos. 40 4,473.00 178,920.00ii) Counterpoise Type 0.00

a) 120 meter length Nos. 393 21,769.00 8,555,217.00b) 280 meter length Nos. 16 50,694.00 811,104.00

8.0

i) Danger Plate Nos. 449 298.00 133,802.00ii) Number Plate Nos. 449 298.00 133,802.00iii) Phase Plate (Set of three) Sets 898 298.00 267,604.00iv) Circuit Plate (Set of two) Sets 449 298.00 133,802.00v) Anti-Climbing Device Nos. 449 1,491.00 669,459.00

9.0 Aviation Requirementsi) Painting of towers MT 490 11,927.00 5,844,230.00

Random rubble stone masonary including excavation (1:5 cement mortar)

Stone bound in galvanising wire netting including excavation

Backfilling and levelling of volumes enclosed by revetment

M15 (1:2:4)Nominal mix Concrete for top seal cover of revetment

Installation of the following tower accessories

Page 11: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 11 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

ii) Installation of following : 0.00a) Span marker No. 40 11,182.00 447,280.00

b)

i) 1 Medium + 2 low intensity Set 25 37,968.00 949,200.00

Obstruction light ( to be provided as per IS:5613)

Page 12: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 12 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

10.0 0.00

km 160 125,244.00 20,039,040.00

Sets 160 2,981.00 476,960.00

11.0 No. 8 14,910.00 119,280.00

Erection of following OPGW Fibre optic Cable & Accessories

a) OPGW Fibre Optic Cable - 24 Fibre (DWSM) including approach cable :One set of intallation hardware shall contain all installation hardware fittings as may be required for 1Km Fibre optic cabling

b) Installation Hardware: OPGW Fibre Cable installation hardware set including all cable fittings & accessories like suspension clamps, tension clamps, vibration dampers, earthing clamps, down lead clamps, in-line splice enclosers etc. for item a) above.

Installation of Fibre Optic Distribution Panel (FDOP) including Pigtails for 24 Fibre type: Indoor type, rock mounted including pigtaild FCPC coupling

Page 13: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission lines Page 13 of 27 Schedule 2

SCHEDULE 2 - ERECTION PORTION

(All prices in Nu./Rs.)

Sl# Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

12.0 0.00

a) Double circuit km 134 559,129.00 74,923,286.00

b) km 26 839,439.00 21,825,414.00

TOTAL FOR SCHEDULE 2 2,649,540,823.00

Date :

Place :

Installation of Insulator Strings complete with arcing horns & necessary hardware, installing & stringing of conductor including fixing of conductor accessories, installing & stringing of earthwire including fixing of earthwire accessories & Way leave & ROW clearance (bush and tree cutting as per the requirement) for

Double circuit - Long Valley crossings (more than 1200 Mrts. Span)

Page 14: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 14 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

A) Proto Assembly of towers a) Tower Type DB + Body/Leg extensions MT 38 654.00 24,852.00b) Tower Type DC + Body/Leg extensions MT 41 654.00 26,814.00c) Tower Type DD + Body/Leg extensions MT 58 654.00 37,932.00d) Tower Type DDS + Body/Leg extensions MT 73 654.00 47,742.00

Sub Total for(A) 137,340.00B) Conductor

1 ACSR MOOSE Conductora) UTS test on stranded conductor No. 1 29,413.00 29,413.00

b) No. 1 9,780.00 9,780.00

c) Corona Extinction Voltage Test (Dry) No. 1 48,900.00 48,900.00

d) No. 1 0.00

Sub Total for(B:1) 88,093.002 AACSR MOOSE Conductor

a) UTS test on stranded conductor No. 1 29,413.00 29,413.00

b) No. 1 9,780.00 9,780.00

c) Corona Extinction Voltage Test (Dry) No. 1 48,900.00 48,900.00

d) No. 1 0.00

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

D.C resistance test on stranded conductor

Radio Interference Voltage Test (DRY)-inclusive

D.C resistance test on stranded conductor

Radio Interference Voltage Test (DRY)-inclusive

Page 15: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 15 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

Sub Total for(B:2) 88,093.00Sub Total for(B):(1)+(2) 176,186.00

C) Earthwire1) For 7/3.66 m G.S. Earthwire

a) UTS test on stranded earthwire No. 1 39,266.00 39,266.00

b) No. 1 39,266.00 39,266.00

Sub Total for (C:1) 78,532.002) For 7/4.5 m G.S. Earthwire

a) UTS test on stranded earthwire No. 1 39,266.00 39,266.00

b) No. 1 39,266.00 39,266.00

Sub Total for (C:2) 78,532.00Sub Total for(C):(1)+(2) 157,064.00

D) Insulators & Insulator stringsD1 Disc insulator units1 120 KN Standard disc insulator(i) Verification of dimensions No. 1 1,374.00 1,374.00

(ii) Thermal mechanical performance test No. 1 45,810.00 45,810.00

(iii) No. 1 52,355.00 52,355.00

D.C resistance test on stranded earthwire

D.C resistance test on stranded earthwire

Power frequency voltage withstand and flashover test (i) dry & (ii) wet

Page 16: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 16 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

(iv) Impulse voltage withstand and flashover test (dry) No. 1 28,795.00 28,795.00

(v) Visible discharge test (dry) No. 1 7,198.00 7,198.00(vi) RIV test (dry) No. 1 10,471.00 10,471.00

(vii) Residual strength test No. 1 45,810.00 45,810.00(viii) Steep-wave front test No. 1 45,810.00 45,810.00

(ix) Impact test No. 1 45,810.00 45,810.00Sub Total for (D1:1) 283,433.00

2) 160 KN Standard disc insulator 0.00(i) Verification of dimensions No. 1 1,374.00 1,374.00(ii) Thermal mechanical performance test No. 1 45,810.00 45,810.00

(iii) No. 1 52,355.00 52,355.00

(iv) Impulse voltage withstand and flashover test (dry) No. 1 28,795.00 28,795.00

(v) Visible discharge test (dry) No. 1 7,198.00 7,198.00(vi) RIV test (dry) No. 1 10,471.00 10,471.00(vii) Residual strength test No. 1 45,810.00 45,810.00(viii) Steep-wave front test No. 1 45,810.00 45,810.00(ix) Impact test No. 1 45,810.00 45,810.00

Sub Total for (D1:2) 283,433.00Sub Total for D1:(1)+(2) 566,866.00

Power frequency voltage withstand and flashover test (i) dry & (ii) wet

Page 17: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 17 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

D2) Insulator strings alongwith hardware fittings

1 Single Suspension Pilot insulator stringi) Voltage distribution test No. 1 34,030.00 34,030.00

ii) Corona & RIV Test No. 1 52,355.00 52,355.00iii) Mechanical Strength Test No. 1 52,355.00 52,355.00

Sub Total for (D2:1) 138,740.002 Single Tension insulator string

i) Voltage distribution test No. 1 34,030.00 34,030.00ii) Corona & RIV Test No. 1 52,355.00 52,355.00

iii) Mechanical Strength Test No. 1 52,355.00 52,355.00Sub Total for (D2:2) 138,740.00

3 Double Tension insulator stringi) Voltage distribution test No. 1 34,030.00 34,030.00

ii) Corona & RIV Test No. 1 52,355.00 52,355.00iii) Mechanical Strength Test No. 1 52,355.00 52,355.00iv) Vibration Test No. 1 130,889.00 130,889.00v) Power Arc Test No. 1 1,047,115.00 1,047,115.00

Sub Total for (D2:3) 1,316,744.004 Triple Tension insulator string

i) Voltage distribution test No. 1 34,030.00 34,030.00ii) Corona & RIV Test No. 1 52,355.00 52,355.00

Page 18: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 18 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

iii) Mechanical Strength Test No. 1 52,355.00 52,355.00Sub Total for (D2:4) 138,740.00Sub Total for D2:(1)+(2)+(3)+(4) 1,732,964.00Sub Total for D:(D1)+(D2): 2,299,830.00

E) Hardware Fittings for insulator strings1 Single Suspension Pilot hardware fitting

No. 1 26,177.00 26,177.00

No. 1 2,617.00 2,617.00

c) Mechnical Strength Test No. 1 6,544.00 6,544.00Sub Total for (E:1) 35,338.00

2 Single Tension hardware fitting

No. 1 2,617.00 2,617.00

b) Slip Strength Test for dead End Assembly No. 1 6,544.00 6,544.00

c) Mechnical Strength Test No. 1 6,544.00 6,544.00

Sub Total for (E:2) 15,705.003 Double Tension hardware fitting

No. 1 2,617.00 2,617.00

a) Magnetic power loss Test for suspension assembly

b) Clamp slip Strength vs. Torque Test for suspension clamp

a) Electrical Resistance Test for dead end assembly

a) Electrical Resistance Test for dead end assembly

Page 19: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 19 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

b) Slip Strength Test for dead End Assembly No. 1 6,544.00 6,544.00

c) Mechnical Strength Test No. 1 6,544.00 6,544.00

Sub Total for (E:3) 15,705.004 Triple Tension hardware fitting

No. 1 2,617.00 2,617.00

b) Slip Strength Test for dead End Assembly No. 1 6,544.00 6,544.00

c) Mechnical Strength Test No. 1 6,544.00 6,544.00

Sub Total for (E:4) 15,705.00Sub Total for E:(1)+(2)+(3)+(4) 82,453.00

F) Accessories for conductor

1

a) Slip Strength test No. 1 5,235.00 5,235.00b) Electrical Resistance Test No. 1 2,617.00 2,617.00c) Chemical analysis of materials No. 1 2,617.00 2,617.00d) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00e) RIV test (dry) No. 1

Sub- Total for (F:1) 62,824.00

a) Electrical Resistance Test for dead end assembly

Mid Span Compression Joint for ACSR MOOSE conductor

Page 20: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 20 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

2 Repair Sleeve for ACSR MOOSE conductor

a) Chemical Analysis of materials No. 1 2,617.00 2,617.00b) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00c) RIV test (dry) No. 1

Sub- Total for (F:2) 54,972.00

3 T-connector for ACSR MOOSE conductor

a) Axial tensile test on welded portion No. 1 2,617.00 2,617.00b) Electrical resistance test No. 1 2,617.00 2,617.00c) Chemical analysis of mateirals No. 1 2,617.00 2,617.00d) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00e) RIV test (dry) No. 1

Sub- Total for (F:3) 60,206.00

4

a) Dynamic characteristics test No. 1 26,177.00 26,177.00b) Vibration analysis test No. 1 26,177.00 26,177.00c) Clamp slip test No. 1 5,235.00 5,235.00d) Fatigue test No. 1 26,177.00 26,177.00e) Magnetic power Loss Test No. 1 26,177.00 26,177.00f) Damper efficiency test No. 1 26,177.00 26,177.00

Vibration Dampers for ACSR MOOSE conductor

Page 21: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 21 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

g) Chemcial analysis of materials No. 1 2,617.00 2,617.00h) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00i) RIV test (dry) No. 1

Sub-total for (F:4) 191,092.00

5

a) Chemical Analysis of materials No. 1 5,235.00 5,235.00b) Clamp Slip Test No. 1 5,235.00 5,235.00c) Vibration test No. 1

39,266.00 39,266.00i) Vertical vibrationii) Longitudal vibrationiii) sub-oscillation

d) No. 1 0.00

e) Tension Compression Test No. 1 5,235.00 5,235.00f) Corona Extinction Voltage Test (Dry) No. 1

52,355.00 52,355.00g) Radio Interference Voltage Test (Dry) No. 1h) Ozone Test No. 1 26,177.00 26,177.00

Sub-total for (F:5) 133,503.00

6

a) Chemical analysis of materials No. 1 3,533.00 3,533.00

Bundle Spacer for twin ACSR MOOSE conductor

Magnetic power Loss Test ( if applicable)-N/A

Rigid Spacer for jumper for twin ACSR MOOSE conductor

Page 22: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 22 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

b) Clamp slip test No. 1 5,235.00 5,235.00c) Magnetic power loss test (if applicable) No. 1 13,088.00 13,088.00d) Tension Compression test No. 1 5,235.00 5,235.00e) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00f) RIV test (dry) No. 1

Sub-total for (F:6) 79,446.00

7

a) Slip Strength test No. 1 5,235.00 5,235.00b) Electrical Resistance Test No. 1 2,617.00 2,617.00c) Chemical analysis of materials No. 1 2,617.00 2,617.00d) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00e) RIV test (dry) No. 1

Sub- Total for (F:7) 62,824.00

8 Repair Sleeve for AACSR MOOSE conductor

a) Chemical Analysis of materials No. 1 2,617.00 2,617.00b) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00c) RIV test (dry) No. 1

Sub- Total for (F:8) 54,972.00

9

Mid Span Compression Joint for AACSR MOOSE conductor

Vibration Dampers for AACSR MOOSE conductor

Page 23: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 23 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

a) Dynamic characteristics test No. 1 26,177.00 26,177.00b) Vibration analysis test No. 1 26,177.00 26,177.00c) Clamp slip test No. 1 5,235.00 5,235.00d) Fatigue test No. 1 26,177.00 26,177.00e) Magnetic power Loss Test No. 1 26,177.00 26,177.00f) Damper efficiency test No. 1 26,177.00 26,177.00g) Chemcial analysis of materials No. 1 2,617.00 2,617.00h) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00i) RIV test (dry) No. 1

Sub-total for (F:9) 191,092.00

10

a) Chemical Analysis of materials No. 1 5,235.00 5,235.00b) Clamp Slip Test No. 1 5,235.00 5,235.00c) Vibration test No. 1 39,266.00 39,266.00

i) Vertical vibrationii) Longitudal vibrationiii) sub-oscillation

d) No. 1 0.00

e) Tension Compression Test No. 1 5,235.00 5,235.00f) Corona Extinction Voltage Test (Dry) No. 1

52,355.00 52,355.00

Bundle Spacer for twin AACSR MOOSE conductor

Magnetic power Loss Test ( if applicable)-N/A

Page 24: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 24 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

g) Radio Interference Voltage Test (Dry) No. 152,355.00 52,355.00

h) Ozone Test No. 1 26,177.00 26,177.00Sub-total for (F:10) 133,503.00

11

a) Chemical analysis of materials No. 1 3,533.00 3,533.00b) Clamp slip test No. 1 5,235.00 5,235.00c) Magnetic power loss test (if applicable) No. 1 13,088.00 13,088.00d) Tension Compression test No. 1 5,235.00 5,235.00e) Corona extinction voltage test (dry) No. 1

52,355.00 52,355.00f) RIV test (dry) No. 1

Sub-total for (F:11) 79,446.00

1,103,880.00

G) Acessories for earthwire

1

a) Slip Strength test No. 1 5,235.00 5,235.00b) Electrical Resistance Test No. 1 2,617.00 2,617.00c) Chemical analysis of materials No. 1 2,617.00 2,617.00

Sub- Total for (G:1) 10,469.00

Rigid Spacer for jumper for twin AACSR MOOSE conductor

Sub Total for (F): (1)+(2)+(3)+(4)+(5)+(6)+(7)+(8) +(9)+(10)+ 11)

Mid-span compression Joint for 7/3.66 GS Earthwire

Page 25: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 25 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

2 Flexible Copper Bond for 7/3.66 mm Earthwire

a) Slip Strength test No. 1 1,308.00 1,308.00Sub-total for (G:2) 1,308.00

3

a) Dynamic characteristics test No. 1 26,177.00 26,177.00b) Vibration analysis test No. 1 26,177.00 26,177.00c) Clamp slip test No. 1 5,235.00 5,235.00d) Fatigue test No. 1 26,177.00 26,177.00e) Damper efficiency test No. 1 26,177.00 26,177.00f) Chemcial analysis of materials No. 1 2,617.00 2,617.00

Sub-total for (G:3) 112,560.00

4 Tension assembly for 7/3.66 mm GS Earthwire

a) Mechanical strength test (excluding clamp) No. 1 2,617.00 2,617.00b) Slip strength test for dead end assembly No. 1 5,235.00 5,235.00

c) Electrical Resistance Test for dead end assembly No. 1 2,617.00 2,617.00

d) Chemical Analysis of materials No. 1 2,617.00 2,617.00Sub-total for (G:4) 13,086.00

Vibration Dampers for 7/3.66 mm GS Earthwire

Page 26: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 26 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

5

a) Slip Strength test No. 1 5,235.00 5,235.00b) Electrical Resistance Test No. 1 2,617.00 2,617.00c) Chemical analysis of materials No. 1 2,617.00 2,617.00

Sub- Total for (G:5) 10,469.00

6 Flexible Copper Bond for 7/4.5 mm Earthwire

a) Slip Strength test No. 1 1,308.00 1,308.00Sub-total for (G:6) 1,308.00

7

a) Dynamic characteristics test No. 1 26,177.00 26,177.00b) Vibration analysis test No. 1 26,177.00 26,177.00c) Clamp slip test No. 1 5,235.00 5,235.00d) Fatigue test No. 1 26,177.00 26,177.00e) Damper efficiency test No. 1 26,177.00 26,177.00f) Chemcial analysis of materials No. 1 2,617.00 2,617.00

Sub-total for (G:7) 112,560.00

8 Tension assembly for 7/4.5 mm GS Earthwire

a) Mechanical strength test (excluding clamp) No. 1 2,617 2,617.00

Mid-span compression Joint for 7/4.5 GS Earthwire

Vibration Dampers for 7/4.5 mm GS Earthwire

Page 27: BOQ_Puna-I as Per Aug, 2010

400 kV Mangdechhu Transmission Lines Page 27 of 27 Schedule 3

SCHEDULE 3 - TYPE TESTING(All prices in Nu./Rs.)

Item Description Unit Qty.Puna-I Rates

Unit Price Total Price

SUPPLY & CONSTRUCTION OF TWO NUMBERS 400 kV DOUBLE CIRCUIT TRANSMISSION LINES FROM POTHEAD YARD OF MANGDECHHU HEP TO JIGMELING (VIA GOLING) - Approx. 80 km each

b) Slip strength test for dead end assembly No. 1 5,235 5,235.00

c) Electrical Resistance Test for dead end assembly No. 1 2,617 2,617.00

d) Chemical Analysis of materials No. 1 2,617 2,617.00Sub-total for (G:8) 13,086.00

274,846.00

4,231,599.00

TOTAL FOR SCHEDULE 3 4,231,599.00

Date : Signature of Bidder:_______________

Name of Bidder :__________________

Place : Seal of the Company :______________

Sub Total for (G): (1)+(2)+(3)+(4)+(5)+(6)+(7)+(8)

Total Type Test charges: (A)+(B)+(C)+(D)+(E)+(F)+(G)