Booster Pumps Multistage Vertical 60Hz
-
Upload
rhusseinpos4765 -
Category
Documents
-
view
231 -
download
2
Transcript of Booster Pumps Multistage Vertical 60Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
1/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
2/28
Our Vision, Mission and Values
To be the industry leader providing best-in-class fluid management
solutions to individual and institutional customers and societies
in our chosen markets.
We will achieve this through our dedicated efforts to enhance the
welfare of all our stakeholders and by living by our values of
commitment, reliability and innovation.
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
3/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
4/28
c o n t e n t s
Gen eral . .. .. ..
Important Notes & Group Perf ormance Curve
Performance Curves, Tables, Dimensions & Weight .
... .. ......
.......................................................6-7
........................................8-23
...... . . . .. . . .. . . . .. . . . .. . . .. . . . .. . . . .. . . .. . . . .. . . . .. . . .. . . . .. . . . .. . . . . .. . . . .. . . . .. . . .. . . . .. . .4
V E R T I C A L M U LT I S TA G E C E N T R I F U G A L P U M P S - M V S E R I E S
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
5/28
3B u i l t t o u g h t o l a s t l o n g .B u i l t t o u g h t o l a s t l o n g .B u i l t t o u g h t o l a s t l o n g .B u i l t t o u g h t o l a s t l o n g .
VERTICALMV SERIES - 60 Hz
MULTISTAGE PUMPS
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
6/28
4 VERTICAL MULTISTAGE PUMPS
G E N E R A LC.R.I. Multistage centrifugal pumps MV series non-self priming, axial suction and delivery
type available with DIN standard port connections. All components like impellers, diffusers & shaft of
these pumps are made of corrosion resistant AISI stainless steel and designed to deliver the best
possible hydraulic efficiency. As the diffuser chambers, impellers, shaft & pump base (casing) are made
of high grade stainless steel S.S. 304/316, these pumps can be used to pump clear water
and are quite hygienic to use in drinking water systems too. O rings and gaskets prevent leakage at the
intermediate casing during high pressure. The replacement of the seal can even be done in the installed
position without removing the pump f rom the booster system. These pumps are reliable, easily serviceable
and used in water boosting units to get trouble f ree service for years together.
Vertical ( ) are
C.R.I. Multistage Vertical pumps are powered by a Totally Enclosed Fan Cooled, A.C. induction motor,
suitable for continuous duty. Motor stator is made of low watt loss steel laminations assembled under
pressure and rigidly locked in the frame. Dynamically balanced rotor ensures vibration and noise free
operations. The varnished impregnated windings made of enamelled copper wire offer excellent resistance.
Shaft of ample size made of quality steel and precisely ground is used for transmitting the rated
Horsepower. Construction of motor frames and usage of quality materials result in high performance and
low temperature rise thereby increasing the life cycle of the motor. Thermal over load protector is
incorporated in all single phase motors. These pumps require an adequate control system.
Applications : Pressure boosting Reverse osmosis system
water supplies Boiler feed HVAC & Chilled water systems High pressure washing Irrigation
Fire fighting systems Industries & General
COMMITMENT | RELIABILITY | INNOVATION
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
7/28
MODEL IDENTIFICATION CODE
Note : To include decimal values in the nominal flow from 0.1 to 0.8 alphabets A to H are used.
MultistageCentrifugal
TypeV - Vertical
NominalFlow
3(inm /h)
Phase - Connection1 = Single Phase-PSC2 = Single Phase-CSCR3 = Three Phase-DOL6 = Three Phase-SD No of Impellers
M X X - XXX / XX X X X
Type of Materials of Construction (M.O.C)Diffuser Chamber / Impeller / Pump base (casing) / Base plates
Suc & Del Ports
Type of port connectionR = RoundP = PJE
S = S.S.304 / S.S.304 / S.S.304 / CI / S.S. 304N = S.S.316 / S.S.316 / S.S.316 / CI / S.S.316
C = S.S.304 / S.S.304 / CI / CI / CIL = S.S.304 / S.S.304 / S.S.304 / S.S.304 / S.S.304T = S.S.316 / S.S.316 / S.S.316 / S.S.316 / S.S.316
Impeller Type A = Trimmed impellerB = Extra trimmed impeller
TECHNIC AL DATA
Power RangeSpeedDegree of protection
Insulation classVersions
SealingDirection of rotationType of DutyFlange typeFlange StandardPipe Connection
0.5 to 40 HP3450 rpmIP 55 (Optional IP44 / IP54)
F (Optional 'B')Single Phase 230V, 60Hz, A.C. Supply (Permanent Split Capacitor-PSC & CSCR) Incorporated withthermal over load protector. Three Phase 460V, 60Hz, A.C. SupplyMechanical seal - Cartridge typeClockwise viewed from driving endS1 (continuous)PJE / RoundDINDN 25, DN 32, DN 40, DN 50, DN 65
PERFORMANCE RANGE
Nominal Flow Rate UptoTotal Head Upto
160 GPM / 10 LPS810 Feet
OPERATION LIMITSSuction Lift UptoMaximum Liquid TemperatureMaximum Ambient TemperatureMax. Operating Pressure RangeStarts per hour
21 Feet- 4 to + 248F
O104 F30 Bar200 Times upto 5.5 HP100 Times above 5.5 HP
5MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
8/28
6 VERTICAL MULTISTAGE PUMPS
COMMITMENT | RELIABILITY | INNOVATION
Part Name
Pump Outer Jacket
Pump Bracket
Pump Base (Casing)
Base Plate
ImpellerDiffuser (Chamber)
Motor Frame
Shaft
Shaft Bush Bearings
Mechanical Seal
Type - C
S.S. 304
C.I.
C.I.
-
S.S. 304S.S. 304
AL / C.I.
S.S. 304 / 431
Sic Carbide / Tungsten Carbide
Sic Carbide & Sic Carbide /
T.C. & Carbon, Viton
Type - S
S.S. 304
C.I.
S.S. 304
C.I.
S.S. 304S.S. 304
AL / C.I.
S.S. 304 / 431
Sic Carbide / Tungsten Carbide
Sic Carbide & Sic Carbide /
T.C. & Carbon, Viton
Type - N
S.S. 316
C.I.
S.S. 316
C.I.
S.S. 316S.S. 316
AL / C.I.
S.S. 316 / S.S 329
Sic Carbide / Tungsten Carbide
Sic Carbide & Sic Carbide /
T.C. & Carbon, Viton
MATERIALS OF CONSTRUCTION
Read our operator's manual carefully before installation
pumpset from dry running Use appropriate size, good quality cable and starter / protection devices Use low friction good quality pipes
The pipe diameters must never be smaller than the pump connections Install pump according to our recommended Head range Reduce
number of bends, elbows, T-bends as much as possible in the pipe line All pumps emp loy a prime move r motor sui table for 230 volts si ngle
phase or 415 volts three phase, 60 Hz, A.C supply Avoid fatal electric al shock or injury by disconn ecting power before working on or around
the pumping system Only technically qualified personnel must perform the works complying with local electricit y rules and regulation s To
reduce the risk of electrical shock during operation, an appropriate earthing is mandatory Maximum permissible supply voltage should lie
between 10% The performance data and curves are at rated voltage and only indicative Pipe sizes mentioned in inches are nominal pipe
sizes and are nearest conversion of mm.
Pump should not be operated dry Install dry run preventor to protect the
I M P O R T A N T N O T E S
ELECTRICAL DATA (3Ph, 460V, 60Hz)
Motor
(kW)0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
(HP)0.5 0.8
1.2
1.6
2
2.6
3.9
4.1
7
9.2
13.5
16.6
24
28
34
45
83
82
82
84
85
84
86
85
87
88
91
87
90
91
91
0.75
0.71
0.71
0.77
0.83
0.83
0.77
0.80
0.89
0.81
0.89
0.92
0.92
0.87
0.91
0.75
1
1.5
2
3
4
5.5
7.5
10
15
20
25
30
40
RatedCurrentin Amps
Motor
Eff. %
PF(cos)
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
9/28
Curve tolerance are according to ISO 9906, Annex A The performance are taken at rated voltage & speed that are only indicative Actua l discharge depends on avai labi lity of water in well / tank , heigh t of wate r column from the suct ion pipe end The measurements
were made with airless water at 20C when pumping liquids with a density higher than of water, motors with corresponding ly higheroutputs must be used The bold curves indicate the recommended performance range Pipe friction losses have not been included inthe performance curves & performance tables The pipe connection threads are given as per BSP standard The given performance arefor specific materials of constructions The main scales of the performance curve are feet and US gpm which have been given for head andflow respectively.
THE CONDITIONS BELOW APPLY TO THE CURVES SHOWN ON THE FOLLOWING PAGES.
P E R F O R M A N C E C U R V E C O N D I T I O N S
0
20
40
60
80
100
120
140
160
180
200
220
240
0
H - (
f e e
t )
H - ( m
)
260
280
100
200
300
400
500
600
700
800
900
Q - (m/h)
Q - (US gpm)
Q - (lps)
M V - 0
0 5
242016
765
10080
1284
604020
4321
0
0
0
120 140 160 180 200
1000300
8 9 10 11 12 13
28 32 36 40 44
M V - 0
1 0
M V - 0
2 0
M V - 0
2 5
M V - 0
4 0
M V - 0
8 0
M V - 1
6 0
M V - 0
1 5
7MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
10/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
11/28
0.50
0
0 2
1.5 2
0.4 0.6
1
0.2
2.5
0.8
106 84 12
MV-005
3450rpm60 Hz
260
H -
( m )
240800
220700
200
180 600
160500
140
120 400
100
300
80
60 200
40
100
20
0 0
0
20
40
60
80
Q - (lps)
Q - (m /hr)
Q - (US gpm)
E F F I C I E N C Y ( % )
H -
( f e e
t )
EFF %
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 25 / 32PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
MVS-005/02 3RMVS-005/03 3RMVS-005/04 3RMVS-005/05 3RMVS-005/06 3RMVS-005/07 3RMVS-005/08 3RMVS-005/09 3RMVS-005/10 3RMVS-005/11 3RMVS-005/12 3RMVS-005/13 3RMVS-005/15 3RMVS-005/17 3RMVS-005/19 3RMVS-005/21 3RMVS-005/23 3RMVS-005/25 3RMVS-005/27 3R
0.370.370.370.550.550.750.750.751.11.11.11.11.51.52.22.22.22.23.0
0.50.50.5
0.751.01.01.0
1.501.501.501.52.02.02.03.03.03.03.04.0
00
6293
122150180210240270300330360390450510570625680740810
0.254
5986116141170205230260290315340370432486549604660716788
0.386
5882
110136162194219246274300326350412465526580633688751
0.508
5378
100126147176200228251275294320379430484534581629682
0.6310466683
109123150169195219235250271328361411455493530586
0.76123850668295119132145170180191209255280320350380408450
NOMINAL FLOW : 5 GPM
MV-5
MVS-005/27 3R
MVS-005/25 3R
MVS-005/23 3R
MVS-005/21 3R
MVS-005/19 3R
MVS-005/17 3R
MVS-005/15 3R
MVS-005/13 3R
MVS-005/12 3RMVS-005/11 3R
MVS-005/10 3R
MVS-005/09 3R
MVS-005/08 3R
MVS-005/07 3R
MVS-005/06 3R
MVS-005/05 3R
MVS-005/04 3R
MVS-005/03 3R
MVS-005/02 3R
9MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
12/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
13/28
0.500
0
00 2
00
20
100
40
20060
80
300
100
Q - (lps)
1.5 2
0.4 0.6
1
0.2
3.5 4
1.0
32.5
0.8
4.5
1.2
Q - (m /hr)
18106 84 14 1612 20 Q - (US gpm)
400120
140
500160
600180
200
700220
800240
260
20
60
EFF%
40
E F F I C I E N C Y ( % )
60 Hz3450rpm
MV-010
22
H -
( m )
H -
( f e e
t )
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 25 / 32PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Last digit '3'Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. stands for 3 phase.
00
0.254
0.508
0.7612
1.0116
1.2620
NOMINAL FLOW : 10 GPM
MV-10
MVS-010/15 3R
MVS-010/13 3R
MVS-010/12 3R
MVS-010/11 3R
MVS-010/10 3R
MVS-010/09 3R
MVS-010/08 3R
MVS-010/07 3R
MVS-010/06 3R
MVS-010/05 3R
MVS-010/04 3R
MVS-010/03 3R
MVS-010/02 3R
MVS-010/02 3R
MVS-010/03 3R
MVS-010/04 3R
MVS-010/05 3R
MVS-010/06 3R
MVS-010/07 3R
MVS-010/08 3RMVS-010/09 3R
MVS-010/10 3R
MVS-010/11 3R
MVS-010/12 3R
MVS-010/13 3R
MVS-010/15 3R
MVS-010/18 3R
0.37
0.55
0.75
1.1
1.1
1.5
2.22.2
2.2
2.2
2.2
3
3
4
0.5
0.75
1.0
1.5
1.5
2.0
3.03.0
3.0
3.0
3.0
4.0
4.0
5.5
89
132
174
227
270
306
348414
457
505
547
590
670
798
80
123
165
215
257
301
345397
440
487
530
573
650
778
72
111
153
201
243
285
327375
418
466
508
551
610
739
57
95
135
184
218
254
296338
380
432
470
508
550
672
38
75
110
153
177
210
249290
333
382
411
441
472
583
13
40
62
105
125
151
178220
260
308
331
357
380
461
MVS-010/18 3R
1MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
14/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
15/28
1MV SERIES - 60 Hz
00
20
100
40
20060
80
300
100
Q - (lps)Q - (US gpm)
400120
140
500160
600180
200
700220
800240
260
5
1.4
24
0.500
0
00 2
1.5 2
0.4 0.6
1
0.2
3.5 4
1.0
32.5
0.8
4.5
1.2
18106 84 14 1612 20 22
MV-015
3450rpm60 Hz
Q - (m /hr)
0
20
40
60
80
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 25 / 32PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Last digit '3'Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. stands for 3 phase.
00
0.386
0.6310
0.8814
1.1318
1.4523
NOMINAL FLOW : 15 GPM
MV-15
MVS-015/02 3RMVS-015/03 3RMVS-015/04 3RMVS-015/05 3RMVS-015/06 3RMVS-015/07 3RMVS-015/08 3RMVS-015/09 3R
MVS-015/10 3RMVS-015/11 3RMVS-015/12 3RMVS-015/13 3RMVS-015/15 3RMVS-015/17 3RMVS-015/19 3RMVS-015/21 3RMVS-015/23 3RMVS-015/25 3R
0.370.550.550.751.11.11.11.5
1.51.52.22.22.22.23.03.03.03.0
0.500.750.751.01.51.51.52.0
2.02.03.03.03.03.04.04.04.04.0
6298
125151188212250278
320345378416490528608670718780
6092118150182210238262
308330362395460505572640685750
5585111140170198220250
290308340372426470535605645710
356075110125145160180
205226250275308350390450475520
153035657989
100112
130145165180190223255270310325
507595
128150175195225
255275305335380425478542575635
EFF %
E F F I C I E N C Y ( % )
H -
( m )
H -
( f e e
t )
MVS-015/25 3R
MVS-015/23 3R
MVS-015/21 3R
MVS-015/19 3R
MVS-015/17 3R
MVS-015/15 3R
MVS-015/13 3R
MVS-015/12 3R
MVS-015/11 3RMVS-015/10 3R
MVS-015/09 3R
MVS-015/08 3R
MVS-015/07 3R
MVS-015/06 3R
MVS-015/05 3R
MVS-015/04 3RMVS-015/03 3R
MVS-015/02 3R
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
16/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
17/28
0 321
0
0
00
0.8
10 155
0.4
100
20
40
5 64 87 Q - (m/h)
25
1.61.2
20 35
2.4
30
2
Q - (US GPM)Q - (lps)
120
200
80
60
300
100
400
500
140
600
160
180
20
40
700
200
220
H - (
f e e t )
800240
260
H -
( m )
EFF% 60
3450rpm60Hz
MV-020
E F F I C I E N C Y ( % )
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 25 / 32PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Last digit '3'Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. stands for 3 phase.
00
0.325
0.9515
1.5825
2.2135
2.3938
NOMINAL FLOW : 20 GPM
MV-20
MVS-020/16 3R
MVS-020/14 3R
MVS-020/12 3R
MVS-020/10 3R
MVS-020/08 3R
MVS-020/07 3R
MVS-020/06 3R
MVS-020/05 3R
MVS-020/04 3R
MVS-020/03 3R
MVS-020/02 3R
MVS-020/01 3R
MVS-020/01 3R
MVS-020/02 3R
MVS-020/03 3R
MVS-020/04 3R
MVS-020/05 3R
MVS-020/06 3RMVS-020/07 3R
MVS-020/08 3R
MVS-020/10 3R
MVS-020/12 3R
MVS-020/14 3R
MVS-020/16 3R
0.37
0.75
0.75
1.5
2.2
2.23
3
4
4
5.5
5.5
0.5
1.0
1.0
2.0
3.0
3.04.0
4.0
5.5
5.5
7.5
7.5
47
94
144
190
245
290337
395
488
579
671
763
44
90
140
185
237
284330
387
479
571
660
736
39
80
127
168
223
268.5314
360
452
541
620
680
32
65
107.5
144
202
247282
322
405
484
539
592
20
41
70
100
137
163182
210
259
333
362
425
16
26
42
75
99
113128
143
180
243
272
310
1MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
18/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
19/28
0 321
0
0
00
0.8
10 155
0.4
100
20
40
5 64 87 Q - (m/h)
25
1.61.2
20 35
2.4
30
2
Q - (US GPM)Q - (lps)
120
200
80
60
300
100
400
500
140
600
160
180
700
200
220
H -
( f e e t )
800240
260
H - (
m )
3450rpm60Hz
MV-025
0
20
40
60
80
EFF %
E F F I C I E N C Y ( % )
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 25 / 32PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Last digit '3'Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. stands for 3 phase.
00
0.6310
1.2620
1.8930
2.2135
2.5240
NOMINAL FLOW : 25 GPM
MV-25
MVS-025/02 3RMVS-025/03 3RMVS-025/04 3RMVS-025/05 3RMVS-025/06 3RMVS-025/07 3RMVS-025/08 3RMVS-025/09 3RMVS-025/10 3RMVS-025/11 3RMVS-025/12 3RMVS-025/13 3RMVS-025/14 3RMVS-025/15 3RMVS-025/16 3RMVS-025/18 3RMVS-025/20 3RMVS-025/22 3RMVS-025/24 3R
0.551.11.11.52.22.22.22.23.03.03.04.04.04.04.05.55.55.57.5
0.751.51.52.03.03.03.03.04.04.04.05.55.55.55.57.57.57.510
6292
125159200220255288330358390424455490525590653720785
6191118153198219242280320348377411445473510572635700756
5480
104140174200220256292319347379410435470530587642701
416482116150166190211248269292322345372398453501550600
305170
100129142166182217234254280302329350400445482530
18385080
109118135150182195210235253275300339370400450
MVS-025/24 3R
MVS-025/22 3R
MVS-025/20 3R
MVS-025/18 3R
MVS-025/16 3R
MVS-025/15 3R
MVS-025/14 3R
MVS-025/13 3R
MVS-025/12 3R
MVS-025/11 3R
MVS-025/10 3R
MVS-025/09 3R
MVS-025/08 3R
MVS-025/07 3R
MVS-025/06 3R
MVS-025/05 3R
MVS-025/04 3R
MVS-025/03 3R
MVS-025/02 3R
1MV SERIES - 60 Hz
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
20/28
18 VERTICAL MULTISTAGE PUMPS
COMMITMENT | RELIABILITY | INNOVATION
DIMENSIONS & WEIGHT
MVS-040/01 3R
MVS-040/02 3R
MVS-040/03 3R
MVS-040/04 3R
MVS-040/05 3R
MVS-040/06 3R
MVS-040/08 3R
MVS-040/10 3R
MVS-040/12 3R
MVS-040/14 3R
0.75
1.5
2.2
3.0
3.0
4.0
5.5
5.5
7.5
7.5
1.0
2.0
3.0
4.0
4.0
5.5
7.5
7.5
10
10
347
379
411
454
486
518
582
656
720
784
267
294
320
340
340
-
-
-
-
-
252
295
295
320
320
354
385
385
424
424
353
385
417
460
492
524
588
662
726
790
353
385
417
460
492
524
588
662
726
790
113
136
136
136
136
-
-
-
-
-
113
136
136
136
136
136
204
204
204
204
140
187
187
187
187
187
257
257
257
257
145
163
163
163
163
163
197
197
197
197
32.50
33.50
34.50
35.50
36.50
37.50
39.50
41.50
43.50
49.50
27.50
28.50
29.50
30.50
31.50
32.50
34.50
36.50
38.50
44.50
28.50
29.50
30.50
31.50
32.50
33.50
35.50
37.50
39.50
45.50
12.00
20.00
21.50
23.00
23.00
-
-
-
-
-
11.00
20.00
20.00
21.50
21.50
26.00
70.50
70.50
71.50
71.50
PUMPMODEL
MOTORPOWER
kW HP L1L2
DIMENSIONS IN mm (Approx)
1PhL3 L4
X
1Ph 3Ph
Y() Z
APPROX. NETT WEIGHTWITHOUT PACKING IN kg.
MVC (R) 3PhMVS &
N(P)MVS &
N(R) 1Ph 3Ph
PUMP MOTOR
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
X
Z
195Sq
8 0 . 0
280.0
L 1
L 2
Y
L 1 + L 2
18.0 X 4NOSPCD 110.0
175.0
130.0
2 6 5 . 0
2 1 5 . 0
X Y
Z
195 Sq
261.0
8 0 . 0
L 2
L 3
L 3 + L 2
175.0
130.0
2 6 5 . 0
2 1 5 . 0
X Y
Z
195 Sq
280.0
8 0 . 0
L 2
L 4
L 4 + L 2
20.0 X 4NOSPCD 110.0
42.040.0
13 X 4Nos 13 X 4Nos
42.0
6 0 . 3 0
(DIN)PN 25 / DN 40
(DIN)PN 25 / DN 40(PJE)
2 6 5 . 0
2 1 5 . 0
175.0
130.013 X 4Nos
NPSHR CURVE
0
0
0
1 2 3 4
10
2
20 30 40 50 60
4 6 8 10 12 14Q - (m/h)
Q - (US GPM)Q - (lps)
0 0
2
1
3
4
8
12
H -
( f e e t
)
H -
( m )
NPSHR
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
21/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
22/28
DIMENSIONS & WEIGHT
MVS-080/03 3R
MVS-080/04 3R
MVS-080/05 3R
MVS-080/06 3R
MVS-080/07 3R
MVS-080/08 3R
5.5
7.5
7.5
11.0
11.0
15.0
7.5
10.0
10.0
15.0
15.0
20.0
477
522
567
612
657
702
473
518
563
608
653
698
-
-
-
-
-
-
385
424
424
495
495
495
-
-
-
-
-
-
204
204
204
223
223
223
257
257
257
312
312
312
197
197
197
225
225
225
44.0
45.0
46.0
47.50
48.50
49.50
39.0
40.0
41.0
42.50
43.50
44.50
41.30
47.60
47.60
110.0
110.0
110.0
PUMPMODEL
MOTORPOWER
kW HPL1 L2
DIMENSIONS IN mm (Approx)
MVS (R)MVC (R)
X
1Ph 3PhY
() Z
APPROX. NETT WEIGHTWITHOUT PACKING IN kg.
MVC (R) MVS (R)
PUMPMOTOR
L2
1Ph 3Ph
Q - (US gpm)
Q - (m/h)
Q - (lps)
4
0
0
1.0
10
0
20168 12
3.02.0 5.04.0
24
6.0
20 40 60 80 100
7.0
00
H - ( f
e e t )
H - ( m )
2
4
6
8
NPSHR20
10
30
NPSHR CURVE
MVC (ROUND FLANGE) MVS & N (ROUND FLANGE)
X
Z
195Sq
9 0 . 0
300.0
L 1
L 2
Y
L 1 + L 2
18.0 X 4NosPCD 125.0
X Y
Z
195 Sq
300.0
9 0 . 0
L 2
L 3
L 3 + L 2
18.0 X 4NOSPCD 125.0
50.065.0
(DIN)PN 25 / DN 50
(DIN)PN 25 / DN 50
2 6 5 . 0
2 1 5 . 0
175.0
130.013 X 4Nos
175.0
130.0
2 6 5 . 0
2 1 5 . 0
13 X 4Nos
20 VERTICAL MULTISTAGE PUMPS
COMMITMENT | RELIABILITY | INNOVATION
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
23/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
24/28
DIMENSIONS & WEIGHT
MVS-160/01 3RAMVS-160/01 3RMVS-160/02 3RBMVS-160/02 3RAMVS-160/02 3RMVS-160/03 3RBMVS-160/03 3RMVS-160/04 3RBMVS-160/04 3RMVS-160/05 3RBMVS-160/05 3RMVS-160/06 3RBMVS-160/06 3RMVS-160/07 3RBMVS-160/07 3RMVS-160/08 3RBMVS-160/08 3RMVS-160/09 3RBMVS-160/09 3RMVS-160/10 3RBMVS-160/10 3RMVS-160/11 3RB
2.24555
7.51111111515
18.518.518.52222223030303030
35.57.57.57.51015151520202525253030304040404040
510510580580580650650720720895895965965
103510351105110511751175124512451319
294---------------------
295354385385385424495495495495495495495495630630630630630630630630
136---------------------
136136204204204204223223223223223223223223271271271271271271271271
187187257257257257312312312312312312312312
SQ340SQ340SQ340SQ340SQ340SQ340SQ340SQ340
201201201201201201305305305305305305305305305305305305305305305305
55.0055.0058.0058.0058.0060.0060.0063.0063.0077.0077.0080.0080.0082.0082.0085.0085.0088.0088.0091.0091.0093.00
51.0051.0054.0054.0054.0055.0055.0059.0059.0073.0073.0076.0076.0078.0078.0081.0081.0084.0084.0087.0087.0089.00
21.50---------------------
20.0026.0070.5070.5070.5071.50110.00110.00110.00120.20120.20131.50131.50131.50172.00172.00172.00188.00188.00188.00188.00188.00
PUMPMODEL
MOTORPOWER
kW HP L1L2
DIMENSIONS IN mm (Approx)
1Ph
X
1Ph 3PhY Z
APPROX. NETT WEIGHTWITHOUT PACKING IN kg.
MVC (R) 3Ph MVS & N (R) 1Ph 3Ph
PUMP MOTOR
MVC (ROUND FLANGE) MVS & N (ROUND FLANGE)
L 1
1 0 5
. 0
18.0 X 8NosPCD 145.0
320.0
L 2
18.0 X 8NosPCD 145.0
PN16 - 25 - 40 / DN65PN16 - 25 - 40 / DN65(DIN)
(DIN)
1 8 5
. 0
1 4 5
. 0
1 8 5
. 0
1 4 5
. 0
L 1
L 2
XY
7 4
. 0
240.0 170.0320.0
14.0 x 4Nos
XY
7 4
. 0
170.0240.014.0 x 4Nos
Z Z
1 0 5
. 0
H - (
f e e t
)
0 0
H - ( m
)
2
4
6
8
5
10
15
20
25
30
Q - (US GPM)
Q - (m/h)
Q - (lps)
0 40 80 120 160 200
0 10 20 30 40
2 4 6 8 10 120
10
NPSHR
NPSHR CURVE
22 VERTICAL MULTISTAGE PUMPS
COMMITMENT | RELIABILITY | INNOVATION
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
25/28
2MV SERIES - 60 Hz
Q - (US GPM)
Q - (m/h)
Q - (lps)
E F F I C I E N C Y ( % )
200
13
1601208040
0 12108642
403020100
900
800
700
600
500
400
300
200
100
H - (
m )
250
200
150
100
50
00
MV-160
3450 rpm60Hz H
- ( f e e t )1000
300
60
40
20
0
80
0
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.The given performance is same for Type - C, S, N
PIPE SIZE : DN 65PERFORMANCE TABLE
PUMPMODEL
MOTORPOWER
kW HP
T O T A L M A N O M E T R I C H E A D I N F E E T
DISCHARGElps
US gpm
Note : Last digit '3'for extra trimmed impeller.
Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. stands for 3 phase, 'A' stands for Trimmed impeller & 'B' stands
00
2.5240
5.0480
7.56120
10.08160
11.34180
12.6200
NOMINAL FLOW : 160 GPM
MV-160
MVS-160/01 3RAMVS-160/01 3RMVS-160/02 3RBMVS-160/02 3RAMVS-160/02 3RMVS-160/03 3RBMVS-160/03 3RMVS-160/04 3RBMVS-160/04 3RMVS-160/05 3RBMVS-160/05 3RMVS-160/06 3RBMVS-160/06 3RMVS-160/07 3RBMVS-160/07 3RMVS-160/08 3RBMVS-160/08 3RMVS-160/09 3RBMVS-160/09 3RMVS-160/10 3RBMVS-160/10 3RMVS-160/11 3RB
2.24555
7.5111111151518.5
18.518.52222223030303030
35.57.57.57.51015151520202525253030304040404040
7585
147165175230271325359410450508541596622690731789813885920970
7582
148165179234272325359419450511540600625700739795819885928981
7679
145160172230251320345409436498527585610687715771793861890950
6571
132149165210240295321380404459490540570631659710735795820877
5265
105120140170201245270315350385420457490540572610632680710751
455887
103121150180211240271325345370400431480512541570601640670
32486985
100119155179209239274279319335379410442462492510551572
MVS-160/11 3RBMVS-160/10 3R
MVS-160/10 3RB
MVS-160/09 3R
MVS-160/09 3RB
MVS-160/08 3R
MVS-160/08 3RB
MVS-160/07 3R
MVS-160/07 3RB
MVS-160/06 3RMVS-160/06 3RB
MVS-160/05 3R
MVS-160/05 3RB
MVS-160/04 3R
MVS-160/04 3RB
MVS-160/03 3R
MVS-160/03 3RB
MVS-160/02 3R
MVS-160/02 3RAMVS-160/02 3RB
MVS-160/01 3RMVS-160/01 3RA
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
26/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
27/28
-
8/12/2019 Booster Pumps Multistage Vertical 60Hz
28/28
BOMBAS C.R.I. ESPAA S.L.,Poligono Industrail El.Bony Calle 31, No.137, 46470 Catarroja(Valencia) Spain.
Tel: +34-96 1842 974 Fax: +34-96 1842 977Email: [email protected] Website: www.bombascri.es
C.R.I. PUMPS (PVT) LIMITED(International Division)
SF. No. 480/481, Sathy Road, Kurumbapalayam, Coimbatore - 641 107. India. Phone : +91-422-3911610, 3911612Fax : +91-422-3911600 e-mail : [email protected] website: www.cripumps.com
C.R.I. PUMPS S .A. (PTY) LIMITEDP.O. Box 6292, Halfway House, Midrand - 1685, Johannesburg,South Africa. Tel : +27-11-8058631 / 32 Fax : +27-11-8058630
e-mail : [email protected] website : www.cripumps.co.za
C.R.I. PUMPS (FZE)P.O. Box 7988, A4-40 SAIF-Zone, Sharjah, U.A.E.Tel : +971-6-5573041 (3 Lines), Fax : +971-6-5573042e-mail : [email protected]
C.R.I. BOMBAS HIDRULICAS LTDAAv. Rodrigo Fernando Grillo, 457, Jd. Manacas,CEP - 14.801-534, Araraquara - SP, Brasil.Fone : +55-16-3331 1099, Fax +55-16-3331 5344e-mail : [email protected] website : www.cribombas.com.br
C.R.I. POMPA SANAY VE TCARET LMTED RKET
10032 Sk. No:12 A.O.S.B. 35620 ili-zmir-Trkiye.Tel:+90-232-328 22 99 Fax:+90-232-328 23 33
E-mail: [email protected] Website: www.cripompa.com
E C - M
V 6 - 0
4 / 1 0 - E
1