BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE...

40
BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE CONNECTION UNDER DIRECT AXIAL AND FLEXURAL PULLOUT LOAD SEYED JAMAL ALDIN HOSSEINI UNIVERSITI TEKNOLOGI MALAYSIA

Transcript of BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE...

Page 1: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE CONNECTION

UNDER DIRECT AXIAL AND FLEXURAL PULLOUT LOAD

SEYED JAMAL ALDIN HOSSEINI

UNIVERSITI TEKNOLOGI MALAYSIA

Page 2: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE CONNECTION

UNDER DIRECT AXIAL AND FLEXURAL PULLOUT LOAD

SEYED JAMAL ALDIN HOSSEINI

A thesis submitted in fulfilment of the

requirements for the award of the degree of

Doctor of Philosophy (Civil Engineering)

Faculty of Civil Engineering

Universiti Teknologi of Malaysia

AUGUST 2015

Page 3: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

iii

“To my beloved parents and my lovely wife, for their encouragement and support”

Page 4: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

iv

ACKNOWLEDGEMENT

First of all, gratefulness of thanks to our creator, “ALLAH” for his

continuous blessing, which make this work neither the first nor the last.

Special thanks to Assoc. Prof. Dr. Ahmad Baharuddin Abd Rahman for

giving this opportunity to work under his supervision and for sharing his great

knowledge and experience with me.

I would like to convey my deepest gratitude to Mrs. Zeinab Deriss for her

support and encouragement. Appreciation is also extended to all people who gave me

heartfelt corporation and shared their knowledge.

Finally, I would like to send my deep appreciations to my family who

brought me up with love.

Page 5: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

v

ABSTRACT

The conventional grouted connections with corrugated aluminium sleeves

have been used widely in precast concrete construction. The main problem of the

conventional grouted sleeve connections is the need for long embedded lengths

reinforcement rebars to achieve full continuity. There is a tendency for the long

rebars to touch the sleeve wall and subsequently preventing penetration of grout

around the rebar. Since the grout inside the sleeve cannot be inspected after

installation, there is doubt that the main rebar is fully bonded. This study proposed a

grouted spiral connection which can overcome the use of long embedded length of

connected rebars. The main objective of this study was to investigate the effect of

spiral confinement on the bond stress-slip relationship. The experimental program

was carried out in two phases, Phase I and Phase II. In Phase I, a total of thirty-six

spiral connections were subjected to increasing direct axial pullout loads. Then, in

Phase II, a total of twelve beams comprising spiral connections were subjected to

flexural pullout loads. Parameters considered in this study were pitch distance and

diameter of spiral connections. The experimental results showed that the use of

smaller pitch distance and spiral diameter resulted in higher bond strength. However,

the spiral diameter had more dominant confinement effect such that it increased the

bond strength of direct and flexural pullout tests very dramatically by 34.5% and

40%, respectively. In addition, lower bond strength from the beam tests was reported

as compared to the axial pullout tests. The bond strengths obtained from the flexural

pullout tests were within the range of 0.74 to 0.79 times the bond strengths of the

axial pullout tests. Finally, analytical equations were proposed to express the bond

stress-slip relationship and bond strength of the grouted spiral connection.

.

Page 6: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

vi

ABSTRAK

Penggunaan sambungan grout konvensional dengan salur aluminium telah

digunakan secara meluas dalam pembinaan konkrit pratuang. Masalah utama

daripada sambungan grout konvensional adalah keperluan panjang tambatan untuk

mencapai kekuatan penuh. Terdapat kecenderungan untuk tetulang bar yang panjang

menyentuh dinding salur dan seterusnya menghalang penembusan grout di sekitar

bar. Oleh kerana grout di dalam salur tidak boleh diperiksa selepas pemasangan,

terdapat keraguan tetulang utama tidak terikat sepenuhnya. Kajian ini mencadangkan

satu sambungan gegelung grout yang boleh mengatasi masalah penggunaan tambatan

tetulang keluli yang terlalu panjang. Objektif utama kajian ini adalah untuk

menyiasat kesan kurungan gegelung ke atas hubungan tegasan ikatan-gelinciran.

Program eksperimen telah dijalankan dalam dua fasa, Fasa I dan Fasa II. Dalam Fasa

I, sejumlah tiga puluh enam sambungan gegelung dikenakan tindakan beban

tegangan paksi. Di dalam Fasa II, sebanyak dua belas rasuk dengan sambungan

gegelung dikenakan beban lenturan. Parameter yang dikaji adalah jarak antara

gegelung dan diameter gegelung penyambung. Keputusan eksperimen menunjukkan

bahawa penggunaan jarak antara gegelung dan diameter gegelung yang kecil dapat

meningkatkan kekuatan ikatan. Bagaimanapun, kesan diameter adalah lebih

dominan dalam meningkatkan kekuatan ikatan dengan peningkatan sebanyak 34.5%

dan 40% masing-masing bagi ujikaji beban paksi dan lenturan. Di samping itu,

kekuatan ikatan yang lebih rendah didapati berlaku pada ujian rasuk berbanding

dengan ujian tegangan paksi. Kekuatan ikatan yang diperolehi daripada ujian

lenturan adalah dalam julat 0.74-0.79 kali ganda kekuatan ikatan tegangan paksi.

Akhirnya, persamaan analitik telah dicadangkan untuk menyatakan hubungan

tegasan ikatan- gelinciran dan kekuatan ikatan bagi sambungan gegelung grout.

Page 7: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

vii

TABLE OF CONTENTS

CHAPTER TITLE PAGE

DECLARATION ii

DEDICATION iii

AKNOWLEDGMENT iv

ABSTRACT v

ABSTRAK vi

TABLE OF CONTENTS vii

LIST OF TABLES xii

LIST OF FIGURES xiv

LIST OF SYMBOLS xx

LIST OF APPENDICES xxii

1 INTRODUCTION 1

1.1 Introduction 1

1.2 Background of Study 5

1.3 Problem Statements 8

1.4 Objective 10

1.5 Scope of Research 11

1.6 Thesis Organization 13

2 LITERATURE REVIEW 14

2.1 Introduction 14

2.2 Bond Mechanisms 15

2.3 Bond of Steel Reinforcement Bars 17

2.3.1 Mechanical Interlocking 18

Page 8: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

viii

2.3.2 Friction 19

2.3.3 Chemical Adhesion 19

2.4 Factors Influencing Bond Behavior 19

2.4.1 Confinement 20

2.4.1.1 Previous Research on the

Confinement

21

2.4.1.2 Effect of Confinement on the

Bond Failure

27

2.4.2 Strength of Bonding Material 29

2.5 Previous Research Studies on Grouted

Connections

30

2.6 Experimental Investigation on the Bond Force

of Splice Bars

35

2.6.1 Comparison with ACI 38

2.7 Bond Stress-Slip 40

2.7.1 Analytical Model of Bond Stress-Slip 40

2.7.1.1 BPE Model 41

2.7.1.2 Haskett et al.’s Model 43

2.7.1.3 Soroushian’s Model 44

2.7.2 Equation od Bond Stress-Slip 46

2.8 Standard Bond Tests 48

2.8.1 Review of Experimental Setups of

Direct Pullout Test

49

2.8.1.1 Single Pullout Test 49

2.8.1.2 Double Pullout Test 50

2.8.2 Review of Experimental Setups of Beam

Tests (Flexural Pullout Test)

51

2.9 Summary 53

3 RESEARCH METHODOLOGY 55

3.1 Introduction 55

3.2 Preliminary Study 58

3.3 Direct Pullout Tests 61

3.3.1 Details of Specimens 61

3.3.1.1 Trial Specimens 61

3.3.1.2 Grouted Spiral Connections 63

3.3.2 Preparations of Specimens

65

Page 9: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

ix

3.3.3 Experimental Setup of Direct Pullout

Load Test

67

3.3.4 Data Acquisition System 68

3.4 Experimental Setups of Flexural Pullout Tests 69

3.4.1 Details of Specimens 70

3.4.2 Preparations of Specimens 73

3.4.3 Specifications of Material for the Beam

Specimens

81

3.4.4 Specifications of Material for the

Grouted Spiral Connections

82

3.4.5 Instrumentations 85

3.4.5.1 Measurement of Load 85

3.4.5.2 Measurement of Slip 86

3.4.5.3 Measurement of Steel Strain 87

3.4.6 Data Acquisition System 88

3.4.7 Load Control 89

3.5 Summary 90

4

PHASE I: BEHAVIOR OF GROUTED SPIRAL

CONNECTIONS SUBJECTED TO DIRECT

AXIAL PULLOUT

92

4.1 Introduction 92

4.2 Tensile Test Results of Grouted Spiral

Connections

93

4.2.1 Mechanism of Tensile Force Transfer in

Trial Specimens

96

4.2.2 Mechanism of Tensile Force Transfer in

others Series

102

4.2.2.1 Failure Modes of the Grouted

Spirals

104

4.2.2.2 Behavior of Tensile Strain in the

Connected Main Bars

107

4.3 Structural Behavior 109

4.3.1 Interlocking Mechanism of Grouted

Spiral Connections

111

4.3.2 Splitting Cracks and Effects 113

4.3.3 Confinement Effects 115

4.4 Performance of Grouted Spiral Connections 116

Page 10: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

x

4.4.1 Performance of Bond Stiffness and Slip 116

4.4.1.1 Effects of Spiral Configuration

on the Slip

118

4.4.1.2 Behavior of Connection Stiffness 121

4.4.2 Evaluation of Bond Strength 123

4.4.2.1 Effects of Spiral Configuration

on the Bond Strength

124

4.5 Summary 130

5

PHASE II: BEHAVIOR OF GROUTED SPIRAL

CONNECTIONS SUBJECTED TO INCREASING

FLEXURAL PULLOUT

131

5.1 Introduction 131

5.2 Flexural Test Results of Grouted Spiral

Connections

132

5.2.1 Mechanism of Force Transfer in Trial

Specimens

135

5.2.2 Flexural Test Results of other Series 137

5.2.2.1 Failure Modes of the Grouted

Spiral Connections

140

5.2.2.2 Behavior of Tensile Strain in

Connected Main Bars

143

5.3 Comparison of Results between Direct Axial

and Flexural Pullout Loads

144

5.4 Design Recommendation 149

5.5 Summary 151

6 ANALYTICAL BEHAVIOR OF GROUTED

SPIRAL CONNECTION UNDER AXIAL AND

FLEXURAL PULLOUT

153

6.1 Introduction 153

6.2 Bond Stress-Slip Behavior of Grouted Spiral

Connections

155

6.2.1 Analysis of Bond-Slip Relationship by

Curve Fitting

155

6.2.2 Modelling of the Bond Stress-Slip

Relationship

158

6.3 Evaluating the Confinement Effect by Bond

Energy

163

6.4 Prediction of Bond Strength of Spiral

Connections in Deformed Steel Bars

168

6.5 Comparison with Orangun’s Equation 172

Page 11: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xi

6.6 Limitations 179

6.7 Summary 180

7 CONCLUSIONS 181

7.1 Summary 181

7.2 Conclusion 182

7.3 Recommendations for Future Research 185

REFERENCES 187

Appendices A-C 193-210

Page 12: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xii

LIST OF TABLES

TABLE NO. TITLE PAGE

1.1 Comparisons of the commercial and proposed connections

of this research

3

2.1 Application of NMB splice sleeve and Lenton Interlok 32

2.2 Test-prediction ratios for bars confined by transverse

reinforcement [45]

39

2.3 The value of pitch distance studied by other researchers 45

2.4 Assessment of the performance of the prediction models 48

3.1 Preliminary feasibility evaluation of specimens in

preliminary study

60

3.2 Details of trial specimens 62

3.3 Dimension of all series in Phase I 64

3.4 Details of grouted spiral connection in Phase II 73

3.5 Mix proportion of concrete in grade 40 81

3.6 Description of concrete in grade 40 82

3.7 Average specifications of Sika Grout-215 84

3.8 Properties for the rib parameters 84

3.9 Tensile test results of steel reinforcement bars 84

3.10 Specifications of strain gauges for deformed steel main bar 87

3.11 The measured data and accuracies 89

4.1 Summary of test results of grouted spiral connection 94

4.2 Average of test results in trial specimens 96

4.3 Average of test results in Series 𝐷𝑠 25, 𝐷𝑠 35 and 𝐷𝑠 45 103

Page 13: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xiii

4.4 Bond stiffness of the grouted spiral connections, MPa/mm 120

4.5 Strength ratio of specimens 128

4.6 Bond strength, (MPa) with respect to different spiral

diameters

129

4.7 Bond strength, (MPa) with respect to different pitch

distance

129

5.1 Test results of flexural pullout loads 134

5.2 Bond strength, (MPa) with respect to different spiral

diameter

139

5.3 Bond strength, (MPa) with respect to different pitch

distance

140

5.4 Comparison of bond strength between axial and flexural

pullout tests

148

5.5 Calculation of required embedded length 151

6.1 Curve-fitting parameter of α and β 161

6.2 Bond energy of grouted spiral connections tested in

Phase I

167

6.3 Bond energy of grouted spiral connections tested in

Phase II

168

6.4 Comparison between test results in Phase I and proposed

Equation 6.6

171

6.5 Comparison between test results in Phase II and proposed

Equation 6.7

172

6.6 Values of parameters used for Equation 6.8 175

6.7 Comparison between test results in Phase I and Equation

6.9

178

6.8 Comparison between test results in Phase II and Equation

6.9

179

Page 14: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xiv

LIST OF FIGURES

FIGURE NO. TITLE PAGE

1.1 Grouted splice connection in precast concrete components

[13]

4

1.2 Mechanism of load transfer [17] 5

1.3 Spiral confinement in splice connections [29] 8

1.4 Projecting the long embedded length in conventional

grouted sleeve [30]

9

1.5 Cross section through grouted sleeve column splice [31] 10

2.1 Grouted sleeve connection and connecting elements [33] 15

2.2 Distribution of bond stress at different levels of pulling

force [36]

16

2.3 (a) Bond force transfer mechanisms [45], (b) typical bond

stress-slip relationship [46]

18

2.4 (a) Plain round bar, (b) lateral pressure parallel to the

transverse rib, (c) lateral pressure perpendicular to the

transverse rib [54]

22

2.5 Typical failure pattern (a) without spiral, (b)with spiral

[56]

23

2.6 Grouted spiral connection (a) four splice bars inside the

spiral [61], (b) four splice bars outside the spiral

24

2.7 Anchorage of beam reinforcement at exterior joints [55] 25

2.8 Stress-slip responses under confinement of transverse

reinforcement [55]

26

2.9 Effect of confinement on the bond failure (a) by splitting

in an embedded bar without any confinement, (b) by

pullout with present of confinement [66]

28

2.10 Relationships of bond stress versus displacement [72] 30

Page 15: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xv

2.11 Proprietary products tested by Jansson [73] 31

2.12 Fatigue test setup by Jansson [73] 32

2.13 Details of test specimens [7] 33

2.14 Proposed bar splice sleeve [33] 34

2.15 Configuration of test specimens given by Ling et al. [59] 34

2.16 Test-prediction ratios for descriptive equations with

confinement provided by transverse reinforcement [45]

39

2.17 Schematic representation of Eligehausen’s tests [42] 41

2.18 BPE model [42] 42

2.19 Haskett et al.’s model [84] 43

2.20 Typical types of pullout tests [91] 50

2.21 Direct Tension Pullout Bond Test (DTP-BT) [91, 92] 50

2.22 Experimental setup of tensile load test by Einea et al [7] 51

2.23 Diagram and reinforcement of RILEM beam test, test

pattern for 𝑑𝑏 ≥16 mm [95]

52

2.24 Modification of RILEM beam tests by other researchers

[97]

53

3.1 Flow chart of the research carried out 57

3.2 Labelling of the specimens 58

3.3 Series of grouted splices tested in preliminary study [98] 59

3.4 Configuration of trial specimens T1, T2 and T3 62

3.5 Configuration spiral with four splice bars in trial specimen

T3

63

3.6 Details of all specimens comprising main bars, spiral, and

splice bars

64

3.7 The arrangement of connections in the PVC before

casting

65

3.8 Preparation of specimens 66

3.9 Installation of strain gauge 67

3.10 Experimental setup of tensile load test 68

3.11 Data acquisition system of tensile load test 68

3.12 Grouted spiral connections in flexural pullout test 70

Page 16: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xvi

3.13 Details of specimen in Phase II 72

3.14 Preparation of formwork 74

3.15 Preparation of reinforcement cage 75

3.16 Preparing the beam specimen 77

3.17 Casting of ready-mix concrete 79

3.18 Compacting of concrete with a hand-held vibrator 80

3.19 Smoothing the surface of beam specimens 80

3.20 Demoulding and preparing the specimens in final step 81

3.21 Position of grouted spiral connection in beam specimen 83

3.22 The rib geometry of deformed steel bar 83

3.23 Position of load cell 86

3.24 Arrangement of LVDTs 87

3.25 Location of strain gauge attached to the main bar 88

3.26 Data acquisition system for flexural pullout tests 89

3.27 Setup of loading frame for flexural pullout tests 90

4.1 Specimen A-T1-S (a) failure mode, (b) force transfer

mechanism

97

4.2 Specimen A-T2-S (a) failure mode, (b) force transfer

mechanism

98

4.3 Comparison of slip between A-T1-S and A-T2-S 99

4.4 Confinement effects contributed by the splice bars in

A-T3-S

100

4.5 Comparison of bond strength between A-T2-S and

A-T3-S

101

4.6 Failure mode of specimen A-T3-S 102

4.7 Pullout failure mode 104

4.8 Mechanism of bar bond-slip failure 106

4.9 Bond stress distribution (modified from Ferguson model)

[36]

107

4.10 Stress-strain in the main connected bar 108

4.11 Failure mode (a) without radial crack, (b) with radial

crack

110

Page 17: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xvii

4.12 Mechanical interlocking mechanism of bond [108] 112

4.13 Componential stresses of resultant stress [108] 112

4.14 Componential stress 112

4.15 Propagation of splitting cracks and effects [111] 113

4.16 Componential derivation of resultant bearing stress [108] 114

4.17 Reduction of shear area due to splitting cracks [108] 115

4.18 Passive confinement generated by spiral 116

4.19 Best-fit straight lines to calculate the bond stiffness of

connection

117

4.20 Comparison of average bond stiffness in all series 119

4.21 Effect of spiral diameter on the average bond stiffness 119

4.22 Bar slips due to micro-space and compressive

deformations of grout [35]

122

4.23 Bar slips due to micro-space and compressive

deformations of grout

122

4.24 Development of inclined cracks [55] 123

4.25 Bond strength versus pitch distance 125

4.26 Stress transfer mechanism 126

5.1 Flexural pullout experimental (a) beam details showing

the spiral connection, unbonded length of rebar, loads and

LVDTs positions, (b) actual beam tested in the laboratory

133

5.2 Grout fracture initiating the bar pullout 135

5.3 Comparison of bond strength between specimens F-T3-S

with splice bars and F-T2-S without splice bars

136

5.4 Bond strength versus spiral diameter under flexural

pullout

138

5.5 Comparison of confined surface area 138

5.6 Bond strength versus pitch distance 139

5.7 The location of the failure in the left side of the beam in

connector

141

5.8 Failure mode (a)-(b) flexural pullout with the grouted

connection located inside the left beam, (c) pullout of the

main rebar

141

Page 18: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xviii

5.9 Stress-strain of specimens under flexural pullout test (a)

F-P15-D25-S, (b) F-P35-D25-S

143

5.10 Comparion of bond strength between direct axial and

flexural pullout (a) bond strength versus spiral diameter,

(b) bond strength versus pitch distance

145

5.11 Stress-strain in the main steel bar (a) specimen A-P15-

D25-S under direct axial pullout test, (b) specimen

F-P15-D25-S under flexural pullout test

146

5.12 Bond stress-slip relationship (a) specimen A-P15-D25-S

under direct axial pullout test, (b) specimen F-P15-D25-S

under flexural pullout test

147

5.13 Level of bond strength of specimens for different series 150

6.1 Analytical behavior of grouted spiral connection 155

6.2 Curve fitting of experimental bond stress-slip of grouted

spiral connection (a) under direct axial pullout, (b) under

flexural pullout

157

6.3 Comparison of bond stress-slip relationships between

experimental results and curve fitting equation of (a)

specimen A-P25-D35-S direct axial pullout test, (b)

specimen F-P25-D35-S under flexural pullout test

158

6.4 (a) Configuration of specimen in research of Soroushian

model [55], (b) equivalent Soroushian model used in the

spiral connections

159

6.5 Comparison between predicted bond stress-slip

relationships with experimental results (a) A-P15-D25-S

(I), (b) A-P25-D25-S (I), (c) F-P15-D25-S, (d) F-P25-

D25-S

161

6.6 Bond energy (a) A-P15-D25-S, (b) A-P15-D35-S and

(c) A-P15-D35-S in direct axial pullout in Phase I

164

6.7 Bond energy (a) F-P15-D25-S (b) F-P15-D35-S and

(c) F-P15-D35-S in flexural pullout in Phase II

165

6.8 Statistical approach- logarithmic regression method for

predicting parametric response (a) direct axial pullout, (b)

flexural pullout

169

6.9 Grout confined area in grouted spiral connections 174

6.10 Comparison between direct axial pullout and Equation 6.9 177

6.11 Comparison between flexural pullout and Equation 6.9 177

Page 19: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xx

LIST OF SYMBOLS

P - Applied load

𝑑𝑏 - Diameter of main bar

𝑙𝑑 - Embedded length

𝜏 - Average bond stress

U - Bond strength of concrete

ƒ𝑛 - Lateral confining pressure

𝑓𝑐𝑢 - Concrete compressive strength

ƒ𝑏𝑡 - Bond stress

𝑇𝑏 - Bond force

𝐴𝑏 - cross sectional area of spliced bars

𝐴𝑡𝑟 - Area of transverse reinforcement normal to the plane of

splitting through the anchored bars

𝐶𝑚𝑖𝑛 - Smaller of minimum concrete cover or ½ of clear spacing

between bars

𝑓𝑦𝑡 - Yield strength of transverse reinforcement

s - Spacing of transverse reinforcement

n - Number of bars developed or splice at the same location

CSo - Side cover

CSi - 1/2 of the bar clear spacing

CS - Minimum (CSo , CSi + 6.4m)

Cb - Bottom cover

Cmax - Maximum (Cb, CS)

𝜏𝑚𝑎𝑥 - Maximum bond strength

𝑆 - Slip

𝑠1 - Slip at maximum bond strength of 𝜏1

α - a curve-fitting parameter

Page 20: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xxi

𝑓𝑐′ - Tensile strength of concrete

𝑓𝑠 - Steel stress

X - Distance from loaded face pullout bond specimen.

x - Distance from center of embedded bar

D - Diameter of cylindrical grout

𝐷𝑠 - Diameter of spiral

𝑃𝑠 - Pitch distance of spiral

𝐿𝑠 - Length of grouted spiral connection

𝐿𝑒 - Embedded length of main connected bar

𝑁𝑐 - Number of Coil

h - Rib height

c - Rib spacing

ʋ - Rib inclination

fc,g - Compressive strength of grout

σ - Stress

Ks - Stiffness

Rs - Strength ratio

fu,b - Maximum stress at failure

Pu - Load capacity

fsy,b - Specified yield strength

T - Tensile load in the main bars of beam specimen

a - Shear span

j - Distance between the resultant tensile and compressive loads

ɤ - Ratios between bond strength of axial and flexural pullout

β - A curve-fitting parameter

Ag - Confined grout, cross sectional area

𝑓spiral - Tensile stress in spiral

Aspiral - Cross sectional areas of the spiral

𝑑𝑠𝑝𝑖𝑟𝑎𝑙 - Diameter of cross sectional area of spiral

𝑑sb - Diameter of splice bar

𝑃g - Tensile strength of grout in connection

𝑃spiral - Tensile load endured by the spiral

Page 21: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

xxii

LIST OF APPENDICES

APPENDIX TITLE PAGE

A Response of grouted spiral connection with deformed steel

bars under direct axial pullout in Phase I

193

B Response of grouted spiral connection with deformed steel

bars under flexural pullout in Phase II

199

C List of publication 210

Page 22: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

CHAPTER 1

INTRODUCTION

1.1 Introduction

The construction industry in Malaysia has shifted from conventional

reinforced concrete system to industrialized building system (IBS) through the

application of precast concrete system. The precast concrete system has led the

building market to an extremely competitive environment. Using this system,

considerable amount of building components are fabricated in factories in a fully

controlled condition by means of proper equipment. The precast concrete system has

considerable advantages such as certainty in cost and time, enhancing occupational

health and safety, achieving higher construction productivity and quality, reliance on

manual foreign labor, and decreasing the cost of construction [1].

In 1960, Ministry of Local Government and Housing visited a number of

European countries for evaluation of their housing development program [2], which

led to initiating IBS in Malaysia. Then, the government dedicated about 22.7 acres of

land along Jalan Pekeliling, Kuala Lumpur to a great project that consisted of seven

blocks of 17 stories flat, 3000 units of low-cast flat, and 40 shop lots [3].

In 2006, the Malaysian construction industry re-introduced the IBS system

with the expectation the new technologies in precast concrete can be adopted for

innovative construction techniques. For instance, the Construction Industry Master

Page 23: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

2

Plan (CIMP) 2006-2015 published in December 2006 was an attempt to plan the

direction for future developments of the Malaysian Construction Industry. In the

2005 Budget, the construction of 100,000 units of reasonably-priced houses using

IBS was pledged by the government. The Surat Pekeliling Perbendaharaan Bil. 7

Tahun has 2008 strongly asserted that the government’s projects must use IBS in

their construction process not less than 70% of the whole structures [1]. These efforts

demonstrate the situation of IBS in the construction industry of Malaysia.

One of the major concerns that commonly arise with regard to the use of

prefabricated precast concrete components is the needs to develop quality

connections in a way to maintain the structural integrity through the precast sections

[4]. In the precast continuous construction system, both the design and structural

details of the precast connections should have the same features of cast-in-place

connection [5]. In this regard, the America Concrete Institute (ACI) has published

different details on how to emulate cast-in-places in the precast construction sites [6].

On the other hand, still there is not enough supplementary information in the ACI

code regarding the design of precast connections in particular the knowledge related

to continuity and bond in reinforcement bars.

In order to achieve full continuity of reinforcement bars for joining precast

concrete components, grouted splice connectors are preferred and employed (see

Figure 1.1). Grouted splice connectors have shown the capability of being used as

connections in the precast concrete structures. These connectors reduced the splice

length for ensuring the continuity of steel bars considerably [7]. The splice

connectors make the installation process simpler and solve the problems of bar

congestion and detailing, especially in structures that are heavily reinforced[8]. For

the first time, in the late 1960s [9, 10], this splice method was introduced by Dr.

Alfred A. Yee upon the invention of NMB splice sleeve® [10]. From that time,

different types of mechanical couplers such as BarSplice Double Barrel Zap

Screwlok©, Lenton Interlok® [11, 12] Lenton QuickWedge©, etc. have been

developed and commercialised. Most of the splice connectors have been invented by

private individuals and are difficult to obtain the technical details due to the

proprietorship rights. Due to limited literature regarding the behavior of grouted

Page 24: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

3

splices connections, researchers prefer to investigate the non-proprietary splice that is

inexpensive. Table 1.1 shows the differences between the commercial connections

and non-proprietary splice connections which were studied in this research. The

commercial splice connections normally required special mould to fabricate and are

made from cast iron. On the other hand, the proposed non-proprietary connectors

required steel pipe, spiral and splice bars only. Concerning the performance, an

adequate splice connector should be capable of providing high quality assurance in

bond strength even with short spliced lengths. In this splices technique, the strength

of the splice joint relies heavily on the anchorage bond.

Table 1.1: Comparisons of the commercial and proposed connections of this

research

Commercial splice connector Proposed splice connector in this research

NMB splice sleeve

Double Barrel Zap Screwlok

Lenton Interlok

Characteristics of commercial splice

connectors:

1. Need special moulds to fabricate

the thread and splice which is

expensive

2. Cast iron is used for the splice

which is brittle

3. Proprietary

Steel pipe with spiral confinement

Spiral confinement with four splice bars

Characteristics of proposed non-proprietary splice

connectors:

1. Steel pipe spiral and splice bars of

connections are easily available in the

market with inexpensive materials

2. These types of connections can be

fabricated easily without any special

mould.

3. Non-proprietary

Page 25: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

4

Figure 1.1 Grouted splice connection in precast concrete components [13]

Usually the bond development has strong effect on the interaction between

the grout and splice bar for the grouted splice connections, that are usually used in

connecting precast concrete components. In fact, the mechanism of load transfer

between the precast concrete components depends on the quality of adequate bond

provided by the grouted splice (Figure 1.2) [14]. Investigation works on the factors

that affect the bond were studied greatly over the last 40 years and as a result,

considerable modifications have been introduced to bond clauses in design codes

worldwide [15]. Detailed evaluations of bond strength and bond behavior are

complicated, as the magnitude of bond strength is influenced by a wide range of

factors. For example, the CEB-FIP Model Code 90 [16] includes not less than 10

parameters which influence the anchorage bond behavior.

Page 26: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

5

Figure 1.2 Mechanism of load transfer [17]

In the bond aspect, one of the key factors that can improve the value of bond

stress is the present of confinement between the steel bar and grout. The confinement

can influence the anchorage bond and reduces the required embedment length of the

spliced steel bars [7, 18-20]. The application of confinement delays early

development of the splitting cracks either by expansion resistance or bridging of

surrounding materials of the steel bars.

This study concentrates on the behavior of proposed grouted splice

connections with spiral confinement. To investigate the behavior of new splice

connections, it is very essential to know the interactions and also internal stress

distribution among the deformed steel spliced bars and its surrounding materials.

1.2 Background of Study

In reinforced concrete structures, the reinforcement bars attain continuity

through lapping full anchorage lengths of the steel bars [21]. On the other hand, the

long bar lapping lengths may be impractical in cases where there is not adequate

space for the accommodation of the required bar development lengths, especially in

structures that are heavily reinforced and in cases where larger bar sizes are used,

Page 27: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

6

leading to impractical lapping lengths, or it may be not permissible to be lap spliced

by codes [8].

In precast concrete structures, prefabricated components such as wall to wall

and column to column need to be jointed together by ensuring the continuity of

rebars from the lower component to upper components. To join the prefabricated

elements of the precast concrete systems, the lengthy lapping system have not been

shown quite appropriate. For example, long extruding starter bars provided for

embedment in the adjoining structural elements in the installation process often cause

problems of transportation and handling. As a result, for ensuring the ease of the

installation and maximizing the speed of construction process, there is a need for

short bar anchorage length

The grouted splice offers a feasible solution to connect the prefabricated

elements during erections. During the assembly process, prior to pouring or pumping

the grout in the sleeves, the short extruding steel bars could be inserted to the pre-

embedded sleeves in the targeted elements. Using this technique, the problem of long

embedded lengths can be solved and the process of handling and installation can be

performed more easily.

In general, using grouted splices, discontinued bars can be spliced at short

embedded bar lengths. Though, the bond performance may be different because of

variations existing in the grouted splice configurations. Knowing these issues, the

grouted splices responses should be investigated, particularly regarding the bond

behavior, for identification of the major factor like confinement that has impact on

the bond mechanism in grouted splices.

The influence of confinement on the ductility and compressive strength of

compression members has been reported by many researchers [22-26]. Their work

was based on the confinement of members along their full length. The confinement

effect using spirals or ties on lap splice lengths and development of the longitudinal

Page 28: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

7

reinforcement was investigated in their work. Based on the shape of confinement,

circular spirals provide a continuous confining pressure around their axial axis [27].

The concept of spirally confined lap splices of deformed bar comes from the

above theory to generate the strength required for connecting the reinforcement bars

together (see Figure 1.3). So, In order to employ spiral confinement in grouted

connections, more investigations are required rather than relying on speculated

predictions. Thus, it is essential to understand the responses of the grouted splices

when subjected to the load cases of direct axial and flexural pullout loads. Other

forces that may occur in the splice are axial force-moment and axial compression-

moment. the work by Kuttab and Dougill [28] has shown that most of the grouted

connections in precast column components experienced axial force–moment

interaction characteristics. Hence, multi-phases of experimental studies are carried

out to study the behavior of proposed connections caused by the bond stress-slip

relationship of individual short deformed steel by spiral reinforcement. The

confinement provided by the spirals is part of the proposed short splicing method

which increases the bond strength. The spirals characteristics and properties are

applied in Industrial Building Systems (IBS) where other types of mechanical spliced

connections could be substituted by this connection.

Page 29: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

8

Figure 1.3 Spiral confinement in splice connections [29]

1.3 Problem Statements

The problems that need to be addressed in grouted splice connections are:

1. The conventional grouted sleeve connector is one of the famous methods for

joining precast concrete components (see Figure 1.4). According to the

finding of Kuttab [28], the combination of axial and flexural loads interaction

characteristics of grouted sleeve connectors has to be equal to the parent

column. Due to this axial and flexural load interaction, long embedded length

of 35 times bar diameter based on BS 8110 [21] is needed to achieve the full

continuity of reinforcement bars. The main problem in using this connection

is the installation process of the grouted sleeve connectors which is quite

difficult and it is not easy to achieve with any accuracy. The main bars in the

sleeve may not always be perfectly located at the centre of sleeve (See Figure

Page 30: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

9

1.5). There is a tendency the long bars to touch the wall of the sleeve in the

precast component, so preventing penetration of grout around the bar and it is

not allowing the grout to fill all the voids inside of the sleeve completely.

Since the grout inside the sleeve cannot be inspected after installation, there is

doubt that the main bar is fully bonded. So, it is necessary to provide the

system which can be assembled by prefilling [8].

2. There is not much research works on the effect of spiral confinement on the

bond behavior of grouted splices. Therefore, there is a need to study the

confinement effects in the grouted splice connectors.

Figure 1.4 Projecting the long embedded length in conventional grouted

sleeve [30]

Page 31: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

10

Figure 1.5 Cross section through grouted sleeve column splice [31]

1.4 Objectives

Owing to these important characteristics, the bond behavior of reinforcement

embedded in grout needs to be investigated accordingly. The key factor governing

the anchored-bar behavior in confined grout is the local bond stress-slip relationship.

Consequently, to develop new splice connections, it is important to understand the

internal stress and the local bond stress-slip relationship between various main

connected bars and their surrounding materials. Failure of bond leads to slippage in

reinforcement bars and consequently failure of structural members.

To achieve the task of solving the problems stated above, this research is

outlined with several main objectives as follows:

i. To investigate the performance of spiral confinement and splice bars to the

behavior of connected deformed steel bars in grouted connections under

direct axial and flexural loads.

ii. To study the effect of spiral configurations on the bond stress-slip behavior of

the deformed steel bars under direct axial and flexural loads.

Page 32: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

11

iii. To study the comparison of direct axial and flexural pullout loads on the bond

behavior of deformed steel bars in grouted spiral connection.

iv. To propose equations for predicting the bond strength and bond stress-slip

relationship of the grouted spiral connections under direct axial and flexural

loads.

1.5 Scope of Research

The scope of the research program includes:

a. The experimental tests of grouted spiral connections with different

configurations of spiral confinement.

b. The investigation of the performance of the proposed grouted spirals when

subjected to load cases of direct axial and flexural pullout.

c. The study of responses of the grouted spirals towards tree considered parameters,

pitch distance of spiral, diameter of spiral and type of main bars.

d. The development of simplified equations for predicting the responses of the

connections under mentioned load cases

e. Additionally, two major phases of experimental tests involves

i) Testing of thirty-six grouted spiral specimens under monotonic direct axial

pullout to study the behavior of the connections under tension.

ii) Experimental testing of twelve full-scale beam specimens, connected with

grouted spirals, under flexural pullout loads to acquire the response of the

steel deformed bars in grouted spiral connections.

Page 33: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

12

Furthermore, the scope of the test results for each phase comprises:

a. Phase I – Direct tensile axial pullout test of grouted spiral connections

i. Failure load capacity

ii. Bond strength

iii. Bond stress-slip behavior

iv. Stress-strain response

v. Failure mode

b. Phase II – Flexural pullout test of the steel deformed bars in grouted spiral

connections

i. Failure load capacity

ii. Bond strength

iii. Bond stress-slip behavior

iv. Stress-strain response

v. Failure mode

Lastly, the scope of analytical research consists of:

a. Analysing the bond stress-slip relationship of the grouted splices under direct

axial and flexural pullout loads from the experimental results in Phases I and II.

b. Deriving equations to predict the bond strength of the grouted spiral connections

under tensile and flexural pullout loads.

c. Evaluating the effect of spiral confinement on the bond stress-slip relationship by

calculating the bond energy

d. Comparison of the experimental test results to other researcher to validate the

data.

Page 34: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

13

1.6 Thesis Organization

Chapter 2 presents a review of the available literature and the present state of

knowledge regarding grouted connections and mechanism of bond stress.

Chapter 3 describes the experimental program, including the details of test

specimens, connection configurations, material specifications, instrumentations, test

setup and procedures.

Chapter 4 presents the results and discusses the responses of grouted spiral

specimens when subjected to increasing direct axial pullout loads.

Chapter 5 displays and discusses the test results and response of full-scale

beam specimens, connected with steel deformed bars in grouted spiral connections,

under flexural pullout loads.

Chapter 6 presents the analytical derivations for predicting the bond strength

response and bond stress-slip relationship of the proposed grouted spiral connections

under direct axial and flexural pullout loads.

Chapter 7 summarizes and concludes the entire research carried out.

Page 35: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

REFERENCES

1. Hamid, Z.A., Kamar, K. A. M., Raham, A. H. A. Industrialized Building

System (IBS). 2009.

2. Thanoon, W. A. M., Peng, L. W., Abdul Kardir, M. R. The Experiences of

Malaysia and other countries in industrialised building system. Proceeding of

International Conference on Industrialised Building Systems. 2003.

3. Kamar, K., M. Alshawi, and Z. Hamid. Barriers to industrialized building

system (IBS): The case of Malaysia. in In BuHu 9th International

Postgraduate Research Conference (IPGRC), Salford, United Kingdom.

2009.

4. Tibbetts, A.J., M.G. Oliva, and L.C. Bank. Durable fiber reinforced polymer

bar splice connections for precast concrete structures. Composites & Ploycon,

2009. 15-17.

5. American concrete insitute. Design Recommendations for Precast Concrete

Structures, ACI 550. 1993.

6. ACI-ASCE Committee. Emulating Cast-in-Place Detailing in Precast

Concrete Structures. 550. 2001.

7. Einea, A., T. Yamane, and M.K. Tadros. Grout-filled pipe splices for precast

concrete construction. PCI journal, 1995. 40(1). 82-93.

8. American concrete insitute. Mechanical Connections of Reinforcing Bars.

ACI 439. 1991.

9. Splice sleeve North America, I.H.e.o.N.S.S.; Available from:

http://www.splicesleeve.com/history.html.

10. Yee, A.A. Splice sleeve for reinforcing bars with cylindrical shell. U.S.

3552787 A. 1986.

11. Albrigo, J., L.J. Colarusso, and E.D. Ricker. Method of forming concrete

structures with a grout splice sleeve which has a threaded connection to a

reinforcing bar. U.S. 5366, 672. 1994.

12. Albrigo, J., L.J. Colarusso, and E.D. Ricker. Reinforcing bar splice and

system for forming precast concrete members and structures. U.S 5468, 524.

1995

13. Spiral Connector Product Guide, H.D.B.a.B.A.L.

14. Pecce, M., Manfredi, G., Realfonzo, R., and Cosenza, E. Experimental and

analytical evaluation of bond properties of GFRP bars. Journal of materials

in civil engineering, 2001. 282-290.

15. Cairns, J. and G. Plizzari. Towards a harmonised European bond test.

Materials and Structures, 2003. 36(8). 498-506.

16. FIB-Féd. Int. du Béton. CEB-FIP Model Code 1990. 1993.

Page 36: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

188

17. kim, Y.m. A study of pipe splice sleeves for use in precast beam-cloumn

connections. Master of sience in enginieering, The University of Texas at

Austin; 2000.

18. Untrauer, R.E. and R.L. Henry. Influence of normal pressure on bond

strength. ACI Journal Proceedings. 1965.

19. Robins, P. and I. Standish. The influence of lateral pressure upon anchorage

bond. Magazine of Concrete Research. 1984. 36(129). 195-202.

20. Moosavi, M., A. Jafari, and A. Khosravi. Bond of cement grouted reinforcing

bars under constant radial pressure. Cement and Concrete Composites, 2005.

27(1). 103-109.

21. British Standard Insitution. Structural Use of Concrete - Part 1: Code of

practice for design and construction. 1997.

22. Pfister, J.F. and A.H. Mattock. High Strength Bars as Concrete

Reinforcement, Part 5: Lapped Splices in Concentrically Loaded Columns.

Portland Cement Association, Research and Development Laboratories,

1963.

23. Pfister, J.F. Influence of Ties on the Behavior of Reinforced Concrete

Columns. ACI Journal Proceedings, 1964.

24. Mander, J.B., M.J. Priestley, and R. Park. Theoretical stress-strain model for

confined concrete. Journal of structural engineering, 1988. 114(8). 1804-

1826.

25. Mander, J., M. Priestley, and R. Park. Observed stress-strain behavior of

confined concrete. Journal of structural engineering, 1984. 114(8). 1827-

1849.

26. Orangun, C., J. Jirsa, and J. Breen. A Reevaulation of Test Data on

Development Length and Splices. ACI Journal Proceedings, 1977.

27. Park, R. Reinforced concrete structures.John Wiley & Sons. 1975.

28. Kuttab, A. and J. Dougill. Grouted and dowelled jointed precast concrete

columns: behaviour in combined bending and compression. Magazine of

Concrete Research, 1988. 40(144). 131-142.

29. Heng, L.J.M.a.J.W.L. Blueprints for Successful Public Housing Development.

Singapore Concrete Institute. 2006.

30. FIB-Féd. Int. du Béton. Structural Connections for Precast Concrete

Buildings: Guide to Good Practice. 2008.

31. Elliott, K.S. and C. Jolly (2013). Multi-storey precast concrete framed

structures. Wiley. 2013.

32. Lancelot, H.B. Mechanical splices of reinforcing bars. Concrete

Construction, 1985. 30(1). 23.

33. Henin, E. and G. Morcous. Non-proprietary bar splice sleeve for precast

concrete construction. Engineering Structures, 2015. 83. 154-162.

34. American concrete insitute. Cement and concrete terminology. ACI Special

Publication. 1967. ACI 116.

35. M. K. Thompson, J. O. Jirsa, J. E. Breen, and R. E . Klingner. Anchorage

behavior of headed reinforcement: literature review. 2002.

36. Ferguson, P.M., J.E. Breen, and J.O. Jirsa. Reinforced concrete fundamentals.

1988.

37. Goto, Y. Cracks formed in concrete around deformed tension bars. ACI

Journal Proceedings. 1971.

38. Mains, R.M. Measurement of the distribution of tensile and bond stresses

along reinforcing bars. ACI Journal Proceedings. 1951.

Page 37: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

189

39. Jiang, D., S. Shah, and A. Andonian. Study of the transfer of tensile forces by

bond. ACI Journal Proceedings.1984.

40. Brenes, F.J., S.L. Wood, and M.E. Kreger. Anchorage requirements for

grouted vertical-duct connectors in precast bent cap systems. 2006.

41. Feldman, L.R. and F.M. Bartlett. Bond strength variability in pullout

specimens with plain reinforcement. ACI Structural Journal, 2005. 102(6).

42. Eligehausen, R., E.P. Popov, and V.V. Bertero. Local bond stress-slip

relationships of deformed bars under generalized excitations. 1982.

43. Soroushian, P. and K.-B. Choi. Local bond of deformed bars with different

diameters in confined concrete. ACI Structural Journal, 1989. 86(2).

44. Hussein, L. Analytical modeling of bond stress at steel-concrete interface due

to corrosion. Master of applied sience. Ryerson University, Canada, Torento;

2011.

45. American concrete insitute. Bond and development of straight reinforcing

bars in tension. ACI 408. 2003.

46. Hong, S. and S.-K. Park. Uniaxial bond stress-slip relationship of reinforcing

bars in concrete. Advances in Materials Science and Engineering, 2012.

47. Treece, R.A. and J.O. Jirsa. Bond strength of epoxy-coated reinforcing bars.

ACI Materials Journal, 1989. 86(2).

48. American concrete insitute. Bond Under Cyclic Loads. ACI 408. 1992.

49. Lutz, L.A. The mechanics of bond and slip of deformed reinforcing bars in

concrete. Cornell University; 1966.

50. Wang, H. An analytical study of bond strength associated with splitting of

concrete cover. Engineering Structures,2009. 31(4). 968-975.

51. Gallus Rehm, C Van Amerongen. The basic principles of the bond between

steel and concrete. Cement and Concrete Association, 1968.

52. Quayyum, S. Bond behaviour of fibre reinforced polymer (FRP) rebars in

concrete. Master of applied sience. University of British Columbia; 2010.

53. Ling, J.H., Ahmad Baharuddin Abd. Rahman, Abdul Karim Mirasa, Zuhairi

Abd. Hamid. Performance of cs-sleeve under direct tensile load: part 1:

failure modes. Malaysian Journal of Civil Engineering, 2008. 20(1). 89-106.

54. Xu.F, Zhimin Wu, Jianjun Zheng, Yu Hu, and Qingbin Li. Experimental

study on the bond behavior of reinforcing bars embedded in concrete

subjected to lateral pressure. Journal of materials in civil engineering, 2011.

24(1). 125-133.

55. Soroushian, P., Ki-Bong Choi, Gi-Hyun Park, and Farhang Aslani. Bond of

deformed bars to concrete: effects of confinement and strength of concrete.

ACI Materials Journal, 1991. 88(3).

56. Ichinose, T., Y. Kanayama b, Y. Inoue c, J.E. Bolander Jr. Size effect on

bond strength of deformed bars. Construction and building materials, 2004.

18(7). 549-558.

57. Ling JH, Ahmad Baharuddin Abd. Rahman, Hamid Z (2008). Failure modes

of aluminium sleeve under direct tensile load. 3rd International conference

on postgraduate education. Malaysia: Penang. 2008.

58. Loo, G.K. Parametric Study of Grout-Filled Splice Sleeve Integarated with

Flexible Aluminium Tube for Precast Concrete Connection. Bs.c thesis,

Universiti Teknologi Malaysia; 2009.

59. Ling, J.H., Ahmad Baharuddin Abd. Rahman, Izni Syahrizal Ibrahim, Zuhairi

Abdul Hamid. Behaviour of grouted pipe splice under incremental tensile

load. Construction and building materials, 2012. 33. 90-98.

Page 38: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

190

60. Ling, J.H., A.B. Abd Rahman, and I.S. Ibrahim. Feasibility study of grouted

splice connector under tensile load. Construction and building materials,

2014, 50. 530-539.

61. Einea, A., S. Yehia, and M.K. Tadros. Lap splices in confined concrete. ACI

Structural Journal, 1999. 96(6).

62. Darwin, D.; Tholen, M. L.; Idun, E. K.; and Zuo. Splice strength of high

relative rib area reinforcing bars. ACI Structural Journal, 1996.

63. American concrete insitute. Building Code Requirements for Reinforced

Concrete. ACI 318. 1962

64. Tepfers, R.. A theory of bond applied to overlapped tensile reinforcement

splices for deformed bars. Chalmers University of Technology; 1973.

65. Eligehausen, R. Bond in Tensile Lapped Splices of Ribbed Bars with Straight

Anchorages. German Institute for Reinforced Concrete, 1979. 118.

66. Francisco J. Brenes, S.L.W., and Michael E. Kreger. Anchorage

Requirements for Grouted Vertical-Duct Connectors in Precast Bent Cap

Systems. Center for Transportation Research The University of Texas at

Austin; 2006.

67. Darwin, D.; McCabe, S. L.; Idun, E. K.; and Schoenekase, S. P. Development

length criteria: bars not confined by transverse reinforcement. ACI Structural

Journal, 1992. 89(6).

68. Esfahani, M.R. and B.V. Rangan. Local bond strength of reinforcing bars in

normal strength and high-strength concrete (HSC). ACI Structural Journal,

1998. 95(2).

69. Esfahani, M.R. and B.V. Rangan (1998) Bond between normal strength and

high-strength concrete (HSC) and reinforcing bars in splices in beams. ACI

Structural Journal, 1998. 95(3).

70. Farndon, S.J. The Effect of Normal Pressure on Bond in Light-Weight

Concret. Loughborough University; 1982.

71. Tepfers, R. Cracking of concrete cover along anchored deformed reinforcing

bars. Magazine of Concrete Research, 1979. 31(106). 3-12.

72. Alavi-Fard, M. and H. Marzouk. Bond of high-strength concrete under

monotonic pull-out loading. Magazine of Concrete Research, 2004. 56(9).

545-557.

73. Jansson, P.O. Evaluation of grout-filled mechanical splices for precast

concrete construction. 2008.

74. Coogler, K.L., K.A. Harries, and M. Gallick. Experimental study of offset

mechanical lap splice behavior. ACI Structural Journal.2008. 105(4).

75. Lee, S.-H. and H.-K. Kim. Development of Steel Pipe Splice Sleeve for High

Strength Reinforcing Bar (SD500) and Estimation of its Structural

Performance under Monotonic Loading. Journal of the Korea institute for

structural maintenance and inspection, 2007. 11(6). 169-180.

76. Abukawa, M. Mortar-filled type reinforcing bar joint. U.S 6851245 B1.

2005.

77. Hope, P.F. Reinforcing bar coupling system. U.S 4666326 A. 1987.

78. Oh, M.H. and E.J. Wilson, Reinforcing bar splice with cutting edge bolts. U.S

20080172979 A1. 2008.

79. Dahl, K.L. High strength grouted pipe coupler. U.S 6679024 B2. 2004.

80. Oliva, M.G. and L.C. Bank. Splice system for connecting rebars in concrete

assemblies. U.S 8413396 B2. 2013.

Page 39: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

191

81. Orangun, C., J. Breen, and J.O. Jirsa. The strength of anchor bars: a

reevaluation of test data on development length and splices.Center for

Highway Research, University of Texas at Austin; 1975.

82. Zuo, J. Bond strength of high relative rib area reinforcing bars., University

of Kansas, Civil and Environmental Engineering; 1998.

83. Zuo, J. and D. Darwin. Splice strength of conventional and high relative rib

area bars in normal and high-strength concrete. ACI Structural Journal, 2000.

97(4).

84. Haskett, M., D.J. Oehlers, and M. Mohamed Ali. Local and global bond

characteristics of steel reinforcing bars. Engineering Structures, 2008. 30(2),

376-383.

85. Adajar, J., Teukai.Y, and Hiroshi.I. An Experimental Study on the Tensile

Capacity of Vertical Bar Joints in a Precast Shearwall. Transaction of the

Japan concrete institue, 1993. 15(2). 1255-1260.

86. Nilson, A.H. Nonlinear analysis of reinforced concrete by the finite element

method. ACI Journal Proceedings, 1968.

87. Kankam, C.K. Relationship of bond stress, steel stress, and slip in reinforced

concrete. Journal of structural engineering. 1997. 123(1). 79-85.

88. Nilson, A.H. Internal measurement of bond slip. ACI Journal Proceedings,

1972.

89. Mirza, S.M. and J. Houde. Study of bond stress-slip relationships in

reinforced concrete. ACI Journal Proceedings, 1979.

90. Rilem/CEB/FIP. Bond test for reinforcing steel: 2.Pullout test. 1970.

91. Tastani, S. and S. Pantazopoulou. Experimental evaluation of the direct

tension-pullout bond test. Bond in concrete from research to standards,

Budapest, Hungary. 2002.

92. Tastani, S. and S. Pantazopoulou. Behavior of corroded bar anchorages. ACI

Structural Journal, 2007. 104(6).

93. Hamza, A.M. and A.E. Naaman. Bond strength of reinforcing bars in

SIFCON. ASCE. 1991.

94. De Larrard, F., I. Shaller, and J. Fuchs (1993). Effect of the bar diameter on

the bond strength of passive reinforcement in high-performance concrete.

ACI Materials Journal, 1993. 90(4).

95. Rilem/CEB/FIP. Bond test for reinforcing steel: 1. Beam test. 1970.

96. E. Cosenza, G. Manfredi, M. Pecce, and R. Realfonzo. Bond between Glass

Fiber Reinforced Plastic Reinforcing Bars and Concrete Experimental

Analysis. ACI Special Publication, 1999. 188.

97. Dancygier, A.N., A. Katz, and U. Wexler. Bond between deformed

reinforcement and normal and high-strength concrete with and without fibers.

Materials and Structures, 2010. 43(6). 839-856.

98. Hosseini, S.J.A. Effect of spiral on the bond stress-slip relationship in the

splice sleeve connector. Ms.c tehsis. Universiti Teknologi Malaysia; 2011.

99. Hosseini, S.J.A., Abd Rahman AB. Effects of spiral diameter on the bond

stress-slip relationship in grouted sleeve connector. Malaysian J Civil Eng,

2013. 12(1).

100. Hosseini, S.J.A., Abd Rahman AB. Analysis of spiral reinforcement in

grouted pipe splices connectors. GRAĐEVINAR Journal, 2013. 65(6). 1-10.

101. Hosseini, S.J.A., Koushfar Kiarash, Abd Rahman AB, Razavi Meysam. The

bond behaviour in reinforced concrete, state of the art, Part 1. Cement-

Wapno-Beton, 2014. (2). 93-105.

Page 40: BOND BEHAVIOR OF GROUTED SPIRAL AND SPLICE …eprints.utm.my/id/eprint/54779/1/SeyedJamalPFKA2015.pdf · vi ABSTRAK Penggunaan sambungan grout konvensional dengan salur aluminium

192

102. Hosseini, S.J.A., Koushfar Kiarash, Abd Rahman AB, Razavi Meysam. The

bond behaviour in reinforced concrete, state of the art, Part 2. Cement-

Wapno-Beton, 2014. (6).

103. ASTM. Standard Test Methods for Testing Mechanical Splices for Steel

Reinforcing Bars. ASTM A1034/A. 2005.

104. Tran, B.H., Y. Berthuad, and F. Ragueneau. Essais PIAF: Pour Identifier

l'Adhérence et le Frottement. 18ème Congrès Français de Mécanique. 2007.

105. ASTM. Standard Test Method for Comparing Bond Strength of Steel

Reinforcing Bars to Concrete Using Beam-End Specimens. ASTM A944-05.

2005.

106. British Standard Insitution. Steel for the reinforcement of concrete, Weldable

reinforcing steel,Bar, coil and decoiled product, Specification. BS 4449.

2005.

107. Abrams, D.A. Tests of bond between concrete and steel. 1913.

108. Ling, J.H., Ahmad Baharuddin Abd. Rahman, Abdul Karim Mirasa, Zuhairi

Abd. Hamid. Performance of cs-sleeve under direct tensile load: part II:

structural performance. Malaysian Journal of Civil Engineering. 2008. 20(1).

107-127.

109. Gambarova, P. and G. Rosati. Bond and splitting in bar pull-out: behavioural

laws and concrete cover role. Magazine of Concrete Research, 1997. 49(179).

99-110.

110. Lura, P., G. Plizzari, and P. Riva. 3D finite-element modelling of splitting

crack propagation. Magazine of Concrete Research, 2002. 54(6). 481-493.

111. Ling, J.H. Behaviour of grouted splice connections in precast concrete walls

subjected to tensile, shear and flexural loads. PhD thesis. Universiti

Teknologi Malaysia, Faculty of Civil Engineering; 2011.

112. Steuck, K.P. Anchorage of Large-Diameter Reinforcing Bars Grouted into

Ducts. University of Washington; 2007.

113. Kemp, E.L., F. Brezny, and J. Unterspan. Effect of Rust and Scale on the

Bond Characteristcs of Deformed Reinforcing Bars. ACI Journal

Proceedings, 1968.

114. Benmokrane, B. and B. Tighiouart. Bond strength and load distribution of

composite GFRP reinforcing bars in concrete. ACI Materials Journal, 1996.