Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill...
Transcript of Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill...
![Page 1: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/1.jpg)
Bomag PM hour service
intervals. Oil fill and drain
locations.
Model's BM2000/50 & 60 T-3 units
![Page 2: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/2.jpg)
Oil drain location- Under rear of unit – open access
door- BM2000/50 only
Engine oil.
15/40 –
53 Qt
Engine
oil filter Hydraulic oil.
ISO-VG 46
61 GAL.
Diesel
Pump drive
Box. ISO-VG 220
4 Qt
![Page 3: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/3.jpg)
BM2000/60 T-3 units
Pump
drive
drain
HYD
oil
drain
Fuel
tank
drain
![Page 4: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/4.jpg)
500 hr Mill drum transmission – oil drain location.
Model specific.BM2000/50
Drain access plug – 70mm socket. Remove to locate trans drain
plug. Need A 8mm Allen socket with minimum 14 inch extension.
Rotate drum down. Drain into receiver of at least 20 QT capacity.
![Page 5: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/5.jpg)
Level plug if unit is with port hole at 10
o'clock
![Page 6: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/6.jpg)
500 hr Drum transmission vent plug location. Remove for
oil draining and filling. Model BM2000/50. 8mm Allen head
socket with 12 inch extension.
![Page 7: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/7.jpg)
500 hr Drum transmission vent & drain plug location. Model
BM2000/60. Rotate drum, locate plugs at 9 o'clock and 6
o'clock positions. 8 mm Allen head socket with 14 inch
extension.
Drum trans, oil
ISO-VG 220
19 Qt
![Page 8: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/8.jpg)
Normal fill is to connect the oil pump hose to drain port via
3/8 pipe- plastic or brass = barb fitting to pump hose.
![Page 9: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/9.jpg)
Pump in 19 Qt -ISOVG220 until you see it at level port. Insert plug at 10
o'clock. Remove pump fitting- insert plug at 6 o'clock.
![Page 10: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/10.jpg)
500 hr Track drive reduction gear, oil drain & fill. Rotate
plugs to 3 o'clock and 6 o'clock positions.8 mm Allen head
socket.
Drain.
Vent & fill level.
Oil 85-140
1.2 Qt
![Page 11: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/11.jpg)
Track chain button head grease fitting. Insert or
remove grease for adjustment.
![Page 12: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/12.jpg)
250 hr Track chain slack adjustment inspection -
At 1 inch deflection from sub frame.
Pry up on chain to check adjustment.
![Page 13: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/13.jpg)
250 hr Mill drum zero mount bearing oil service. Remove inspection
door. Jack-up side plate to expose drain plug.
Grease every 10 hr- during
Drum rotation.
Vent plug. Oil fill plug.
Oil ISO-VG 220
1.5 Qt
Drain plug
![Page 14: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/14.jpg)
250 hr Mill drum- zero mount bearing oil service.
Raise side plate to access plugs.
Drain plug.
Fill plug.
![Page 15: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/15.jpg)
500 hr Hydraulic pump drive box service. Drain is located under unit.
See page 2 0r 3.
![Page 16: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/16.jpg)
Hydraulic pump drive box - oil level dip stick. Oil ISO-VG
220
8 Qt
![Page 17: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/17.jpg)
1000 hr – Hydraulic oil & filter service. Level
indicator & filter location.
![Page 18: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/18.jpg)
50 Hr grease service. Track strut columns. Insert grease
until you can see it push out of lower steering collar – All 4
![Page 19: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/19.jpg)
250 Hr strut columns & steering collar keyway
inspection.
Inspect keyway mount bolts.
Retorque to 150 Fb.
Grease columns until
you see grease push out of collar.
Inspect keyway for excessive
wear.
![Page 20: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/20.jpg)
Filter Part #
• BM2000/60 T-3
•
• 1 Engine oil filter `05710633
• 1 Primary fuel `05825015
• 2 Secondary fuel `05716779
• 2 Low PSI Hyd` filter 330172118
• 2 High PSI Hyd` filter `07993014
• 1 Fuel filter gasket kit `05718032
•
![Page 21: Bomag PM hour service intervals. Oil fill and drain …...Bomag PM hour service intervals. Oil fill and drain locations. Model's BM2000/50 & 60 T-3 units Oil drain location- Under](https://reader033.fdocuments.in/reader033/viewer/2022041803/5e528f6625a2d654301e40a4/html5/thumbnails/21.jpg)
Description / Oil Type / Quantity / Hour intervals
ENGINE OIL 15/40 53 QT 13.25 GAL, 250
HYDRAULIC OIL VG 46 244 QT 61 GAL, 1000
ENGINE ANTIFREEZE SG 1.132 / Ph 8.0/9.0 Shell Blue ASTMD 1122 106 QT 26.5 GAL, 2000
MILL DRUM TRANS, ISO VG 220 19 QT 4.75 GAL, 500
MILL DRUM ZERO MOUNT BEARING ISO VG 220 1.5 QT 250
TRACK DRIVE 85/140 1.3 QT X-4 500
MILL DRUM ANTIFREEZE 354 QT 88.5 GAL, 2000
Pump Splitter Box ISO VG 220 4 QT 1 GAL, 500
FUEL FILTER 500