BOILERS - Ferguson

6
©2020 Ferguson Enterprises, LLC. 1020 2204759 PROSELECTPRODUCTS.COM BOILERS Gas-Fired Cast Iron Water Boiler Gas-Fired Cast Iron Steam Boiler VFO Oil-Fired Cast Iron Water Boiler Oil-Fired Cast Iron Water Boiler

Transcript of BOILERS - Ferguson

Page 1: BOILERS - Ferguson

©2020 Ferguson Enterprises, LLC. 1020 2204759

PROSELECTPRODUCTS.COM

BOILERS

Gas-Fired Cast Iron Water Boiler

Gas-Fired Cast Iron Steam Boiler

VFO Oil-Fired Cast Iron Water Boiler

Oil-Fired Cast Iron Water Boiler

Page 2: BOILERS - Ferguson

©2020 Ferguson Enterprises, LLC. 1020 2204759

PROSELECTPRODUCTS.COM

BOILERS

PROSELECT® FORCE™ proudly carries a variety of durable boilers that are trusted to withstand the consistent demands of everyday use.

When your customers need reliable heating equipment, choose PROSELECT FORCE.

Gas-Fired Cast Iron Water Boiler

pg. 3

Gas-Fired Cast Iron Steam Boiler

pg. 5

Oil-Fired Cast Iron Water Boiler

pg. 7

VFO Oil-Fired Cast Iron Water Boiler

pg. 9

1 2

Page 3: BOILERS - Ferguson

3 4

Gas-Fired Cast IronWater Boiler

Contact your local sales associate or visit proselectproducts.com for more information.

Standard Features

Technical Information

BOILERS

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

• 84% AFUE – meets DOE 2021 regulations• NEW DESIGN! – Can be piped from either side (industry standard locations) – Concealed controls and components• Hydrolevel® Hydrostat™ 3200 combination

high limit/circulator relay control – Built-in LWCO – Energy-saving thermal targeting software – Outdoor reset available (not included)• Honeywell® S8610 electronic ignition control

& Honeywell gas valve• Grundfos® Alpha 2™ circulator• Built-in draft diverter• Drop-in replacement boiler in most installations• Reliable cast iron heat exchanger • Steel nipples• Limited lifetime warranty on heat exchanger,

1-year manufacturer’s warranty on parts• Automatic vent damper

Model Input1

(MBH)

DOE HeatingCapacity(MBH)

Net AHRIRating2 (MBH) AFUE%

Flue Collar

Diameter

Water Content

(Gallons)

“W”Dimension

(Inches)

Approx. Shipping

Weight (lbs.)

Boiler Weight (lbs.) ALT 1

FORCE02E 38 32 28 84.0 4 1 14 202 143 FORCE02ENRHG1FORCE03E 68 57 50 84.0 4 2 14 254 180 FORCE03ENRHG1FORCE04E 102 85 74 84.0 5 3 16 304 231 FORCE04ENRHG1FORCE05E 136 114 99 84.0 6 4 19 357 284 FORCE05ENRHG1FORCE06E 170 142 123 84.0 6 5 22 405 332 FORCE06ENRHG1FORCE07E 204 170 148 84.0 7 6 25 462 382 FORCE07ENRHG1FORCE08E 238 199 173 84.0 7 7 28 518 438 FORCE08ENRHG1FORCE09E 272 227 197 84.0 8 8 31 564 484 FORCE09ENRHG1

All dimensions and specifications are subject to change without notice.1. Input ratings can be used for elevations up to 2,000 ft. Refer to System Start-up and

Checkout section of IO&S Manual for ratings above 2,000 ft.2. Net AHRI water ratings shown are based on a piping and pickup allowance of 1.15.

The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.

Supply 1-1/4"

Electrical

Gas1/2" (2-6 sec.)3/4" (7-9 sec.)

Return 1-1/4"

Floor Line

6" Min (see Note 1)

13"25"

31"

0"

35"

6"

0"

16"

18"

24"27"

40"

63"

Floor Line

23" (see Note 2)

40"

4" W 1"

26-3/4"

33-1/4"

Supply 1-1/4"

Electrical

Gas1/2" (2-6 sec.)3/4" (7-9 sec.)

Return 1-1/4"

Floor Line

6" Min (see Note 1)

13"25"

31"

0"

35"

6"

0"

16"

18"

24"27"

40"

63"

Floor Line

23" (see Note 2)

40"

4" W 1"

26-3/4"

33-1/4"

NOTES:1. Minimal radial distance around

vent pipe and breeching for single-wall metal pipe vent connector, otherwise follow vent connector manufacturer’s recommended clearances.

2. Add height required to maintain 6” clearance from all breeching components. Vent damper may be installed in vertical or horizontal section of vent connector within reach of vent damper harness.

3. Boiler can be installed on combusible flooring.

Boiler Conversion Kits (0-2,000 ft. altitude)

Natural Gas Standard – from factory

LP Gas

110197-01 (2 sections)

109874-01 (3-6 sections)

109874-02 (7-9 sections)

• Roll-out switch, spill switch, ASME relief valve (30 psi) • Trapezoidal legs with nylon glides – permit easy positioning

during installation

Page 4: BOILERS - Ferguson

5 6

Model

DImensions (inches)

AFUE%

Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRI

Steam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.) Alt 1“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28" 40-7/16 4 81.9 69 56 42 175 350 FORCESTEAM03NHFORCESTM04 16 28" 40-7/16 5 82.0 103 84 63 263 420 FORCESTEAM04NHFORCESTM05 19-1/4 28" 40-7/16 6 82.0 138 113 85 354 485 FORCESTEAM05NHFORCESTM06 22-1/2 28" 40-7/16 6 82.1 172 142 107 446 555 FORCESTEAM06NHFORCESTM07 25-3/4 30" 40-7/16 7 82.1 207 171 128 533 620 FORCESTEAM07NHFORCESTM08 29 30" 40-7/16 7 82.2 241 199 149 621 690 FORCESTEAM08NH

• Natural gas (LP conversion kit available)• Electronic ignition• Built-in draft diverter – fits in

low spaces• Cast iron heat exchanger, meets ASME boiler

code and pressure vessel code• Metal section connectors resist chemicals,

increase the life of the boiler

• Fully assembled• 10-year limited warranty• Fully packaged• Insulated jacket• Pressure limit• 15 psi safety valve• Honeywell gas valve• Hydrolevel probe-type LWCO

Gas-Fired Cast Iron Steam Boiler

Standard Features

BOILERS Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

The Net AHRI Steam Ratings shown are based on a piping and pickup allowance of 1.333. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

Ratings shown are for installations at sea level and elevations up to 2,000 feet.

BOILERS

Contact your local sales associate or visit proselectproducts.com for more information.

• Steam pressure gauge• Built-in draft diverter• Flame roll out switch• Blocked vent switch• Vent damper• Drain valve

“B”

“A”

VENT DAMPER

SAFETY VALVE

DRAIN VALVE (OR ALTERNATIVE 2" RETURN)

2" SUPPLY

2" RETURN

PRESSURE GAUGE

LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW

NORMAL WATER LINE

PRESS LIMIT

LOW WATER CUT-OFF

GAUGE GLASS28 5/8

GAS VALVE

J-BOX TRANSFORMER

& RELAY

“C”

Technical Information

Page 5: BOILERS - Ferguson

7 8

• 87% AFUE, ENERGY STAR® certified• 0.6 to 1.30 GPH in four sizes• Chimney vented, optional direct vent kit

available (sizes 140, 182)• 3-pass cast iron heat exchanger• Fully-opening, reversible, cast iron swing door• Return water mixing tube• Steel section connectors• Lifetime limited warranty on

heat exchanger• Fully packaged• 3450 RPM flame retention Beckett oil burner• Beckett GeniSYS primary control

Oil-Fired Cast Iron Water BoilerStandard Features

BOILERS

BOILERS

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

Contact your local sales associate or visit proselectproducts.com for more information.

112"NPT SYSTEM RETURN

CONNECTION

19" MIN.BURNER SWING

DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)

FRONT SERVICECLEARANCE

(FLUEWAY CLEANING)

DRAIN VALVE

CLEANOUT COVER

SMOKEBOX COLLAR

COLLARDIA.

FLAMEOBSERVATION

PORT

BURNERSWINGDOOR

TEMP/PRESSUREGAUGE

RELIEFVALVE

BECKETT AFGBURNER(SHOWN)

SPANNER BAR W/ADJUSTABLE LEGS

112"NPT SYSTEM

SUPPLYCONNECTION

2138"

3178"

BOILERCONTROL

NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.

12" MINREAR SERVICE

CLEARANCE(SEE NOTE 1)

1314"

20 "34 5 "3

4

SMOKEBOXPRESURETAPPING

31116"

IMMERSIONWELL

RIGHT VIEW REAR VIEWFRONT VIEW(SEE NOTE)

B

A

C

MIN.

Model

Min. Chimney Requirements Direct Vent SystemRound Inch

Diam.Rectangle(Inches)

Height(Feet)

Kit PartNumber

Vent Connector Diameter (In.)

FORCEOIL084-E 6 8 x 8 15 N/A N/AFORCEOIL115-E 6 8 x 8 15 N/A N/AFORCEOIL140-E 6 8 x 8 15 106401-01 5FORCEOIL182-E 7 8 x 8 15 106401-01 5

112"NPT SYSTEM RETURN

CONNECTION

19" MIN.BURNER SWING

DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)

FRONT SERVICECLEARANCE

(FLUEWAY CLEANING)

DRAIN VALVE

CLEANOUT COVER

SMOKEBOX COLLAR

COLLARDIA.

FLAMEOBSERVATION

PORT

BURNERSWINGDOOR

TEMP/PRESSUREGAUGE

RELIEFVALVE

BECKETT AFGBURNER(SHOWN)

SPANNER BAR W/ADJUSTABLE LEGS

112"NPT SYSTEM

SUPPLYCONNECTION

2138"

3178"

BOILERCONTROL

NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.

12" MINREAR SERVICE

CLEARANCE(SEE NOTE 1)

1314"

20 "34 5 "3

4

SMOKEBOXPRESURETAPPING

31116"

IMMERSIONWELL

TOP VIEW

Note:Return fittings and drain valve shipped loose. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.

Model

Dimensions (Inches)

Burner Capacity

Net AHRI

Ratings (MBH)

AFUE%

WaterContent(Gal.)

Heating Transfer Surface

Area(Sq. Ft.)

Approximate Shipping Weight (lbs.) ALT1GPH MBH

DOE HeatingCapacity(MBH)A B C

FORCEOIL084-E 17 24 5 0.60 84 74 64 87 7.7 13.29 475 FORCEOIL084EGBHDRFORCEOIL115-E 17 24 5 0.80 115 101 88 87 7.7 13.29 475 FORCEOIL115EGBHDRFORCEOIL140-E 23 24 6 1.00 140 123 107 87 11.08 20.29 567 FORCEOIL140EGBHDRFORCEOIL182-E 29 30 6 1.30 182 160 139 87 14.46 27.29 660 FORCEOIL182EGBHDR

The Net AHRI Ratings shown are based on a piping and pickup allowance of 1.15.

• Return water mixing tube• Grundfos Alpha2 circlulator• Draft regulator• Electronic ignitor 14KV• Clean cut fuel pump• Tridicator• Relief valve• Drain valve• Integrated lifting legs (for level installation)

Technical Information

Page 6: BOILERS - Ferguson

• ENERGY STAR® certified 87% AFUE models available• Available with tankless water heater (DHW coil)• Chimney vented• Cast iron sectional heat exchanger – Assembled with reliable, long life, metal

push nipples• Swing-away cast iron burner door• Grundfos® Alpha2™ high-efficiency ECM circulator• Beckett® AFG burner and GeniSys™ primary control• Hydrolevel® HydroStat 3250-Plus combination high

limit/circulator relay control – Energy-saving thermal targeting

software, outdoor reset available

Standard Features

Technical Information

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

BOILERS

VFO Oil-Fired Cast Iron Water Boiler

Contact your local sales associate or visit proselectproducts.com for more information.

• Fully packaged sectional oil boiler• Limited lifetime warranty on heat exchanger, 1-year

manufacturer’s warranty on parts• Tridicator temperature/pressure gauge• ASME relief valve (30 psi) • Drain valve• Fuel pump• Electronic ignitor• Made in U.S.A.

RELIEF VALVE

FLAME OBSERVATION

PORT

FLUE COLLAR

‘A’ ‘B’

‘C’ DIA.

BUILT-IN DOMESTIC WATER HEATER W/ 3/4” CONNECTIONS

BOILER CONTROL

OIL BURNER W/ PRIMARY

CONTROL

TEMP/PRESSURE GAUGE

SUPPLY

24 5 8

14 1 2

12 1 4

3 5 8

2 1 8

1 1 2

3 3 4

5“

1 3 8

RETURN

31 5 8

1 1 2

DRAIN VALVE

BURNER SWING DOOR CLEARANCE (OPEN 90°)

FLOOR LINE

SEE NOTE 2

FRONT VIEW RIGHT SIDE VIEW

3 1 2

11”

9”

THE

NEW YORKER

Minimum chimney requirements: 8”w x 8”d x 15’h* Tankless coil is optional, for model numbers with tankless coil, add a “T” after “FORCEVFO” (eg: FORCEVFOT-5-190);

“ALT1” column numbers for boilers featuring tankless coils, add “T” as a suffix (eg: FORCEVFO3ET)** Requires field installation of Hago or Delevan replacement nozzle supplied with boiler(1) MBH refers to thousands of BTU per hour(2) Based on standard test procedure prescribed by the United States Departement of Energy at combustion conditions of

13.0% CO2(3) Net AHRI Ratings are based on piping and pickup allowance of 1.15 for water

Model*

Burner Capacity DOEHeating Capacity(MBH)2

Net AHRI

Ratings(MBH)3

AFUE(%)

Dimensions (Inches)

ShipWeight(lbs.)

TanklessDHW*(GPM)

ReplacementNozzle

Input(GPH)

Input(MBH)1 A B

Flue Collar

C ALT1*FORCEVFO-3-075 0.75 105 92 80 87.0 173/8 81/4 57/8 560 3.00 FORCEVF03E —FORCEVFO-3-100 1.00 140 122 106 86.3 173/8 81/4 57/8 560 3.25 FORCEVF03E** 0.85 x 60B

FORCEVFO-4-120 1.25 168 148 129 87.0 223/8 107/8 67/8 680 3.75 FORCEVF04E —FORCEVFO-4-150 1.50 210 182 158 86.0 223/8 107/8 67/8 680 4.00 FORCEVF04E** 1.25 x 60BFORCEVFO-5-175 1.75 245 214 186 86.4 273/8 133/8 77/8 800 4.25 FORCEVF05E —FORCEVFO-5-190 1.90 266 231 201 86.1 273/8 133/8 77/8 800 4.75 FORCEVF05E** 1.50 x 45B