Boiler con estufa de leña

download Boiler con estufa de leña

of 33

Transcript of Boiler con estufa de leña

  • 7/30/2019 Boiler con estufa de lea

    1/33

    FREE-HOT WATERFrom Your Wood Stove

    By: Jack Atchinson

    Pleas read this in its entirety before commencing work.

    This CD-ROM Book has many pictures please waitfor them to load! (This may take a few minutes)

  • 7/30/2019 Boiler con estufa de lea

    2/33

    Hot WaterWe all know how expensive it can be... paying for hot water. Utilities are

    going up with no end in site. If you heat your home with wood, thumb your noseat those big utility bills. Save yourself a sizable chunk of money by heating yourwater at the same time- for free!

    Your hot water needs can be met with one of the following systems in thisbook. Building the stand alone type system, or tying in to your existing hotwater heating, will immediately lower your energy cost, and recoup the very lowcost of installation and materials quickly.

    The Systems

    We will be using your existing wood stove as a heat source. There are twotypes of systems: one uses gravity and thermo-siphon circulation (requiring nopump) and the other system uses a small in-line circulating pump. If you have afireplace insert type woodstove, you cannot use the thermo-siphon option. Youwill have to use an inline circulating pump system (shown later in the book),which is no problem. As you read on, you will be able to decide which of thesystems will best suit your needs.

    Thermo-SiphonThis is a beautiful thing! Thermo-Siphon uses heat and gravity to circulate hot

    water. No pump needed! Weve solved our hot water needs this way for years,and its a great feeling knowing theres no moving parts, or power needed to turnon the faucet and get hot water.

    This drawing shows the basic system:

  • 7/30/2019 Boiler con estufa de lea

    3/33

    Here notice the water tank is mounted at least 2 feet higher than the woodstove. It needs that much lift minimum for thermo-siphon to work properly. Wehave our 40-gallon tank setting in the attic, next to the wall. So the weight ispositioned over the top plate of the outside wall, being very strong, and on top ofthe ceiling joist. The tank is strapped to the wall also.

  • 7/30/2019 Boiler con estufa de lea

    4/33

    Cold water from the house service is connected to the Cold or C -water Inmarked on the top of the tank, exactly like it would be connected to a normalwater heater. Cold water enters the tank. Notice it has an internal length of piperunning down to the bottom of the tank. This keeps the cold water entering at thebottom so the hot water can rise and stay at the top.

    In this system, the drain valve at the bottom of the tank is removed. This isthe cold water supply to the bottom of the copper coil, on the wood stove. Coldwater circulates from the lower part of the coil, heats as it rises up the coil, andreturns to the H or Hot -water In, marked on the top of the water tank. Fromthat point, the Hot water is teed off to your hot water service for your home. Forsafety there is two (2) pressure relief valves installed, also known as pop offvalves in the system. One valve is on the tank (comes with every residential hotwater heater), this relives any tank pressure. The other we install at the bottomof the coil, BEFORE the drain valve (other wise it would be useless). These pop

  • 7/30/2019 Boiler con estufa de lea

    5/33

    off valves release pressure that could produce steam, which is very dangerous.********PLEASE NOTE THERE IS NO POP OFF SAFTEY VALVE AT THELOWER END OF THE COIL IN THESE PICTURES! There should be one there,and we dont recommend not installing it! If the steam pressure builds withnowhere to escape, it explodes the pipe. This is not good, and could seriously

    harm you or your family. This is why the pop off valves are used. By using two,one on each end of the system, you are covered and insuring a safe system.Both of the valves output needs to be plumbed out side, or underneath the subfloor of the house so the hot water can escape safely.

    All plumbing must angle upwards slightly to the storage tank in the thermosiphon system so no air pockets can develop. Air pockets can and will stopcirculation.

  • 7/30/2019 Boiler con estufa de lea

    6/33

    Lets Get Started

    The Tank

    We use an electric hot water heater tank for water storage free from thejunkyard. These tanks are plentiful, and can be found in good condition. Manypeople find out electricity is an expensive way to heat water, so they usuallyreplace these perfectly good electric tanks with gas ones. Gas is better, but thecost of gas is skyrocketing yearly. The dump is more than glad to give theseaway.

    The reason we use an electric, instead of a gas powered water heater isthe electric water tank has no fire flue, or hollow center like the gas model. Theelectric tank is a full round tank with no burner inside, it uses a heating elementthat screws into the side. We wont be using this, and dont even need to removeit. You can buy a fancy and expensive hot water storage tank like the ones theyuse for solar systems, and boiler systems, but there is no need. Even buying anew electric water heater is cheaper.

    Standard home hot water heater tanks are nicely set up with all the pipeconnections we need. This is after all, what they are designed for... were justgoing to use our wood stove for the heat source. They even come with one

    pressure relief valve, but we will be using two, so you will need to buy one more(or better yet, snatch one off another tank while your at the dump).

    The trick in finding a good tank is to look for one thats not rusted out. This iseasy! Look for a tank that does not have any big dents. This means it probablyhasnt been smashed or dropped hard. Look for one that looks pretty new. Thedate is on the label. Look for one that doesnt have a rusted out bottom. Ive hadgreat luck with these, and Ive never had to take one back. Talk with theattendant at the dump, and ask if you can bring the tank back and chooseanother one if it leaks. Usually they never object to this, but if they do, so what?The dump fee for one tank cant be much, and usually is free- because theyrecycle the metal in these tanks.

    Next, find a tank as big as you can get for your thermo-siphon system. Youneed to size the tank a little bigger than your needs. A small tank heats up tofast, and runs out of hot water to fast. Find a 35-gallon size minimum for a 2-person household. 40 Gallon or bigger is even better. If you decide to go withthe thermo-siphon system, you will be mounting the tank in your attic (explained

  • 7/30/2019 Boiler con estufa de lea

    7/33

    later on), or on the second floor etc., so adequate support for this extra weightneeds to be considered. The bigger the tank, the heavier it gets. Water weighsabout 8 pounds per gallon.

    Plumbing Techniques

    Plumbing was not at the top of my list for enjoyment. And my skills werepretty weak. But guess what? with the right techniques, and understandableinstructions you can do it! And, you will find out as I have- its easy! Youllwonder why you hadnt tried it before. Its a great feeling of accomplishment, notto mention a handy money saving skill!

    We will be working with copper tubing for the most part. The coil type, andthe rigid 10 lengths. You may also be working with some galvanized pipe.Again, there are easy ways to properly work with these materials, making youlook like a pro with very little practice. And, even if your work doesnt look like apros right off the bat, with my instructional help it will be functional and sound.

    There are many books available on these techniques, and buying one may help.

    Copper

    There are two different connection techniques for copper. For flexible tubingwe will be using a flare connection. For rigid copper pipe we will be solderingour connections. Dont let the term soldering scare you! Its so easy and fast,you wont want to work with the regular old galvanized pipe anymore (but stillthats no big deal).

  • 7/30/2019 Boiler con estufa de lea

    8/33

    Flaring Copper

    This connection requires flaring tools, and a tubing cutter. See picture above.Buy decent quality ones at Home Depot or Wal-Mart. I always try to buy qualitytools, and these stores usually have a good price for quality. We will be workingwith 1/2 inch copper tubing. There will only be 2 flare connections, one at eachend of our copper coil.

  • 7/30/2019 Boiler con estufa de lea

    9/33

    Cut copper tubing with the tubing cutter by opening the cutter, and placing iton the spot you wish to cut. Lightly close the clamping cutter and turn the toolaround the tubing. As you continue, tighten the cutter clamp and turn. Not to

    tight, because you dont want to squash the pipe out of round. Proceed untilthe cutter cuts through. Nice tool, isnt it? Beautiful cut.

  • 7/30/2019 Boiler con estufa de lea

    10/33

    The next step is to slide the proper size brass flare nut onto the tubing. Wewill be using a 1/2 female brass flare connector. Get these at Home Depot, oryour local hardware, theyre not much money. After you slide the flare nut on thetubing, find the 1/2 position hole marked on your flaring tool die, and clamp itonto the tubing leaving a slight bit of tubing above the flare. Next, clamp on theflaring clamp tool with the cone into the tubing.

  • 7/30/2019 Boiler con estufa de lea

    11/33

    Tighten the tool down hard into the tubing to make the flare. This will take...and I suggest, a few practice trys to make good flares. Ask the Home Depot guyto show you how. They re glad to do this for you. No big deal, you can do flareslike a pro!

    ********DO NOT USE TEFLON TAPE OR ANY OTHER SEALANT ON FLAREFITTINGS!!

    Soldering Copper

    Soldering copper is really easy. Youll need a small propane bottle, like theone you use for your Coleman lantern and stove. Buy a small brass propanetorch with a spark striker to light it, or you can spend a little more and buy thetorch with the auto built in lighter like I have. This fits all mini propane bottles.

    Buy a small roll of silver solder for copper pipe, some solder flux, a small brush toapply the flux, and some steel wool or sand paper. All these items you will find atany hardware or building supply outlet.

    We will be using 3/4 copper pipe. Building codes require type M for thecold-water side, and type L which is heavier, for the hot water side. To join thepipe we use copper slip fittings for what ever angle or connection needed.

    The process is this:

    (In case you cant make out the words above): Joining without tinning1. Clean end of pipe with steel wool2. Apply flux with brush or squirt tube3. Push fitting onto pipe and heat4. Apply solder, melted solder will flow up into joint

    Clean the connecting joint of the pipe and fittings with steel wool or sandpaper to make a shiny clean connection. Apply a thin coating of the solder flux

  • 7/30/2019 Boiler con estufa de lea

    12/33

    with a brush to both the pipe and fitting, then install in the desired position. Thismakes the solder flow evenly. Roll out about 4 of solder off the roll, and startyour propane torch. The flame doesnt have to be full blast, medium flame isfine. Position your work so the flame doesnt catch anything on fire!

    You can use a piece of concrete board, like the stuff used under tilebathrooms, as a flame shield. Heat the pipe joint with the flame evenly. Soonhold the solder near the joint and the flame, so it heats up also. Lightly touch thesolder at the joint. As you heat it you will see it start to melt. Apply it sparingly,and lightly as it sucks the solder into the joint. Work it all around the joint, as yousee it fill in. It takes a little practice not to use gobs of it, but when you do putsome gobs on it, dont worry. It will seal fine. When you see the solder seal intothe joint stop and let it cool. A little goes a long way.

  • 7/30/2019 Boiler con estufa de lea

    13/33

    Here is another way shown by pre-tinning (soldering the joint):

    (In case you cant make out the words above): Tinning copper pipe joints1. Clean end of pipe with steel wool2. Heat end of pipe and coat with solder3. Wipe off excess4. Grip fitting with pliers, heat and apply solder to joint, tap out excess5. Heat fitting and push into pipe6. Heat and apply more solder if needed. Finished joint should be smooth all

    the way around.

  • 7/30/2019 Boiler con estufa de lea

    14/33

    Thats all there is to it! If it doesnt look pretty, dont worry. We re not tryingout for the worlds most beautiful soldering contest. This process is veryforgiving. If you dont feel youve done a good job, or it looks messed up (butmost likely it will seal fine), hold the fitting with channel lock or regular pliers, and

    re-heat the joint until the fitting comes off. You can shake the excess solder off(be careful solder is HOT!) the fitting and pipe when its hot. Then you can startover. No big deal!

    Galvanized Pipe

    Youll need to work with a little bit of galvanized pipe, when you tie into yourexisting water heater (if you have existing galvanized). When connectingdifferent types of metal plumbing with copper, you need to use what they call adielectric union (see picture below). This is a connector that joins the two

    different types of metals. This is necessary because when you connect copper,or aluminum etc., to galvanized or bare steel. It makes the steel rust, and rust outquickly by a process called electrolysis. It also can make the copper corrode.This is more common with soft water that has a very high mineral content. Theunion allows you to solder the copper on one side, and screw in steel pipe in theother with a sealant. All building supplies have them.

  • 7/30/2019 Boiler con estufa de lea

    15/33

    Shown is a dielectric union joining copper pipe to galvanized pipe:

    When working with steel (galvanized) pipe, always use two pipe wrenches.One to tighten with, and the other to tighten against. This way you will not bind,damage, or loosen any other plumbing your connecting to. The next importanttechnique is to use Teflon paste on both the male, and female sides on the pipethreads. This stuff is great! Its easy to apply, it makes the pipes thread easier,and it seals like crazy. You dont have to tighten the pipe connection with thebrute force of King Kong. Just tighten until the joints snug tight.

    One more tip... test the pipe joints for a dry fit first making sure the threads arenot banged up. This is common with some pipes, even new from the store. Ifsome threads on your existing plumbing are found to be crossed or banged up alittle, no problem. Buy a thread die, to re-fix the threads. You start the die on thethreads, and then using a crescent type adjustable wrench tighten the die on thepipe going back in forth until the threads are fixed. This is a good way to cleanup old rusty threads too! Well now youre ready to add plumbing to your resumeof skills!

  • 7/30/2019 Boiler con estufa de lea

    16/33

    Connecting the SystemBy now youve begun to think about what system will work best for your

    situation. Once youve decided on either a thermo-siphon system, or stand alonesystem using a circulation pump (shown later), or tying into your existing waterheater system using a circulation pump (shown later). They all use the sameplumbing techniques as Ive outlined above, plus some additional directionsdetailed next.

  • 7/30/2019 Boiler con estufa de lea

    17/33

    Mounting the Water Tank

    (Notice the Pop-off relief valve above with its discharge plumbed outside)

    Wherever you decide to locate your water tank, make sure your homesstructure can handle the extra weight. Dont just set it up in the attic and forget it!Seek advice from an experienced contractor/builder or structural engineer, orlocal building inspector. Make sure youll have room to install the plumbing.Make sure you plumb the pop off valve so it can escape outside the house, orunder the house sub floor, according to your local safety building codes. Be sureto strap down the water tank so it cant fall over incase of an earthquake, etc. It

    is advised to purchase or make a trough or spill pan, one where the water tanksits in case of a leak. These pans can be connected to drain pipe in case of acatastrophic leak, the water will safely go outside.

  • 7/30/2019 Boiler con estufa de lea

    18/33

    The Wood Stove Copper Heating Coil

    Buy a 50 coil of 1/2 copper tubing from your building supply (shown below).We will be wrapping it right onto your wood stove flue pipe at the base of thestove. This can be done with out removing the pipe, unless your damper is in theway. On a six inch flue pipe, 50 of tubing will wrap on about 29 times, and beabout 16 1/2 tall measured from the top of the stove. This will heat 35 gallons ofwater overnight with a stoked slow burning fire. With a hotter fire, water heatsfaster.

  • 7/30/2019 Boiler con estufa de lea

    19/33

    Its great if your flue damper (if you even have one in the flue pipe) is above16 1/2 from the top of the woodstove. If it is lower, you can either re-locate ithigher, and plug the old holes (or get a new pipe section), or wrap the pipearound it (below then above it). It is more desirable to have the pipe wrapcontinuously touch all the way up, with no gaps. This is better for heating, butwill not make a huge difference on performance.

    Start by unpacking the coil of tubing. Stretch out about 12. Hold it at the

    base of your flue pipe (do I need to mention letting the stove cool down first?). Atthe back, with your left-hand hold the end down, and hold the coil with your righthand. You simply wrap clockwise from the bottom up. You let more tubing off ofthe coil as you go around, holding the bottom firmly (get help to hold the bottomdown if necessary), and applying downward pressure, and inward pressure asyou work coiling up the flue pipe. Its really easy to wrap a tight coil with a bit ofeffort.

  • 7/30/2019 Boiler con estufa de lea

    20/33

    Start of the coil wrap. Notice the female flare fittings on each end.

    This shows consecutive bends working around. Carefully keep downwardand inward tension as you go around, and at the same time unwind the larger

    coiled tubing. You can connect another 50 of tubing if more heat is needed, justdont use solder fittings. Use a strong flare union. This one wrap is fine for 2people and 35-40 gallons. Remember, to size your tank and coil needsaccordingly.

  • 7/30/2019 Boiler con estufa de lea

    21/33

  • 7/30/2019 Boiler con estufa de lea

    22/33

    A fairly tight coil is best. 2 people can work together one wrapping, the otherholding the bottom end of the coil. Do not kink the coil!

  • 7/30/2019 Boiler con estufa de lea

    23/33

    Now you have a straight end sticking out on the bottom (point it towards thedirection you want your plumbing to go), and you have an end at the top of thecoil. All fittings need to be brass when using copper. This does not rust, and

  • 7/30/2019 Boiler con estufa de lea

    24/33

    does not need a special union that is used with steel. The next step is to connecta brass female 1/2 flare fitting on each end, using your flaring tool.

    On the bottom end, you will connect a brass fitting... 1/2 female flare to 3/4male pipe. Then solder a copper 3/4 female thread pipe to 3/4 slip thread fitting

    to a 3/4 copper tee (See Pic). Always USE TEFLON SEALANT ON PIPETHREAD FITTINGS, BRASS OR GALVINIZED!! From the tee solder a...

    Connect the cold side of the system (from the lowest part of the storage tank,most likely the drain) to the bottom end of your coil. At the bottom of the watertank is a drain hose valve. Remove this. There will be a 3/4 pipe thread hole inthe tank where the valve was. As shown in the system diagrams (see drawings),this is where you connect the cold water feed to the heater coil. For thecirculation pump system, install a 4 galvanized pipe nipple where the drain valvewas, then a 3/4 tee to install the valve on one side, and a 3/4 dielectric union

    with a 3/4 slip to solder in the 3/4 copper pipe. (See thermo-siphon drawing). Ifyou are using the thermo-siphon system remove the tank drain valve, and installa 3/4 nipple, then the dielectric union to solder on the 3/4 copper pipe.Run your copper pipe soldering the necessary angle fittings to the lower end ofthe heating coil tee.

  • 7/30/2019 Boiler con estufa de lea

    25/33

    This is the cold (from the storage tank) inlet side of the coil pictured.NOTE**** The space in this picture between the TEE fitting on the left, and thehose drain valve on the right is WHERE YOUR SECOND POP-OFF VALVESHOULD BE INSTALLED!!! Then drained to the outside of the house. DO NOTFORGET!!!

    Connect the Hot side of the coil (the top) to your water tank with copper pipeand whatever angles you need to solder in. Remember you need a dielectricunion if your water heater has steel pipe.

    Make sure your flare fitting connections are very tight using open-endwrenches, or crescent wrenches to tighten them snugly. DO NOT USE TEFLONOR ANY OTHER SEALANT ON FLARE FITTINGS!!

    With the thermo-siphon system, it is important all plumbing slants slightly

    upwards to the tank so there is no possibility for an air pocket to develop. Do notplumb high in one place, then slant down, and back up again. This will alsocreate an air pocket. It doesnt matter with a circulation pump system.

  • 7/30/2019 Boiler con estufa de lea

    26/33

    Circulating pump system

    Installing the water tank above your wood stove not practical? No worries.Use your existing water heating system, and tie in or plumb in your wood stove.This way of operation has many benefits. You dont need to scrounge upanother tank. Your electric or gas fired water heater will work fine. It just wonthave to work as much! Your woodstove provides the heat. You can use thesystem as you normally would, and in the summer, your water heater takes over.Or, you can add solar water panels like we do to take over the heating job...when its time to put the wood stove to sleep for spring and summer.

  • 7/30/2019 Boiler con estufa de lea

    27/33

    This drawing shows the basic system:

  • 7/30/2019 Boiler con estufa de lea

    28/33

    Here we have basically the same system as thermo-siphon, but with thewater tank at the same level or lower than the heat source, thus gravity thermo-siphon cant take place. The addition of an inline pump provides the circulation.

    This small electric circulation pump... utilizing very little energy, moves orpushes the water through the system. The water drain always has to be at thelowest part of the system, and is not located at the wood stove as before. It isnow installed at the base of the water heater. The two (2) pressure relief popoff valves remain. One at the bottom of the stove coil, and one on your waterheater tank for safety.

    Buy a quality circulation pump. This will be the most expensive item in your system.Buy a pump with the proper voltage for your home.

    This is an EL-Sid 12 volt circulation pump; it is the best and most efficient for 12V systems:

    EL-SID Brush less Hot Water Circulation PumpCan be purchased at: www.realgoods.com

  • 7/30/2019 Boiler con estufa de lea

    29/33

    These tiny brush less, magnetic drive circulators can be driven by PV modulesor 12 volt batteries for closed-loop circulation in solar water heating systems, individualspace heat zones and individual loop radiant floor loops. Model SID10 is designed tobe powered by a 10 watt PV module and can pump 2.5 gallons per minute at no headand 12 GPM at 2.5 feet of head at 17 volts input. It can circulate water in a well-designed

    solar water heating system with two 4 x 10 collectors. Model SID10B is designed to bebattery powered and has the same specifications at 12 volts. You can also find the rightpowered 110v to 12v converter to power this pump, and use your 110-volt house current.

  • 7/30/2019 Boiler con estufa de lea

    30/33

    For 110 Volt systems this Grundfos Pump has a handy timer and is ready to use:

    It can be found at:http://rewci.com/whhohotwaci.html?engine=adwords!992&keyword=%28hot+water +circulation%29

    Specs:Timer: 24 hr, 3 position, 15-minute intervals. Electrical Cord: 10' Power: 115 VACPump Data: Flow Range: 0-3.4 U.S. GPM Head Range: 0-3.5 U.S. Feet Motor:Single Phase, 115V Min. Fluid Temperature 36 Degrees F Max. Fluid Temperature150 Degrees F Max. Working Pressure: 145 PSI

  • 7/30/2019 Boiler con estufa de lea

    31/33

    Valve Technical Data: Patented Technology Integral Check ValveANSI/NSF61 & IAPMO Approved. CUL/UL/UL EPH/UPC listed. Many other 110-voltagecirculation pumps are available. Try www.realgoods.com or www.grainger.comBoth type pumps are well under $300.

    Final NotesMake sure your water storage tank is larger than your needs for the most part.

    Having an undersized tank will cause you to use up your hot water faster, and thenyou have to wait for more to heat up. Also, if you wind up not using the smaller tankshot water, after awhile it gets to the point where the tank is satisfied (full hot), and youstart recycling heated water. The worst that will happen is your pipes will start to shake,rattle, and roll, then your pop off pressure relief valves will open and shoot water outside.

    When this happens, simply turn on the hot water, and use it. Use it in the washer, takea bath, wash the dishes, etc. This will fill cold water into the tank.

    With a larger sized tank, you never use it all up, so you have plenty, and it nevergets satisfied.

    ONE WORD OF CAUTION*********

    Use a full 50 of copper tubing for your coil. NEVER connect lengths of tubing by asolder joint to increase the length of your coil. The heat from the wood stove will

    de-solder it. You can use a solid flare connection.

    Never run the wood stove without water in the coil system. Running it dry will heatand anneal the metal, and make it brittle! If you have water with a very high mineralcontent, you may experience corrosion in your copper pipes connected to the coil. Ifso install dielectric unions on each side of the coil to isolate it, then you may have toreplace the coil every couple of years or so, but this is an easy, inexpensive maintenanceitem compared to high water heating utility bills.

    Never, use your system with the house main cold water shut off. If you do this, whenyou turn on the faucet, youre removing water that cannot be replaced by new incoming

    cold water. The system cant circulate, water stops moving and continues to heat until itbecomes steam! This will be relieved by your pop off valves, but stresses the plumbing.

    Never, drain you system with a hot wood stove. Let it go out and cool down first.Then fill the system before you restart the wood stove. If you use a circulation pump,it has to pump continuously while the wood stove is hot and working. Do not stop yourcirculation pump while the wood stove is hot. Most pumps are thermostaticly controlled,

  • 7/30/2019 Boiler con estufa de lea

    32/33

    and this will turn it on and off automatically as needed.

    *******NOTE THIS HOT WATER WILL BE HOT!! TEACH YOUR CHILDREN TO BE VERYCAREFUL AND TURN ON THE COLD WATER FIRST! **********

    Your interest in heating hot water is a very worthwhile venture, as your cost will continueto climb if youre dependent on utility companies for energy. Using fuel such as woodfor a dual purpose is not only cost saving, but waste reducing also.

    Many books and internet websites can be found on the subject of using solar hot waterpanels for heating water in the summer, and radiant indoor heating systems which all canbe tied into your Free-hot water wood stove system.

    DisclaimerThis instructional CD-ROM book is sold for informationalpurposes only. Use this information at your own risk. We haveno way to know your skills as a plumber, or engineer, and

    therefore cannot be responsible for your use of this informationabove.

    This information is advisory only and is not intended to replacesound advice or judgment by a licensed contractor or engineer.

    The author and publisher disclaims all warranties, whetherexpressed or implied, including any warranty as to the quality,accuracy, safety, or suitability of this information for anyparticular purpose. Any use of the information in this book is

    evidence of acceptance of these terms.

    The SchoolFactory Publishing Company, and author assume

    no responsibility for errors or omissions in these materials.These materials are provided "as is" without warranty of anykind, either express or implied, including but not limited to, the

    implied warranties of merchant ability.

  • 7/30/2019 Boiler con estufa de lea

    33/33

    This is Copy Written Material

    This instructional CD cannot be recorded, re-written, copied,sold, or distributed in any manner what so ever. TheSchoolFactory Publishing Company reserves the right to

    prosecute to the fullest extension of law anyone who uses thiswork as specified above.

    Free Hot Water- from your Wood Stove

    2002 The SchoolFactory Publishing ASCAP ALL RIGHTS RESERVEDContact info: [email protected]