BNU-LW Gateway · Fire Alarm Stand Alone Operation - PQCPA11A0E / PQCPB11A0E - PQCSS520A0E Korean...
Transcript of BNU-LW Gateway · Fire Alarm Stand Alone Operation - PQCPA11A0E / PQCPB11A0E - PQCSS520A0E Korean...
LG Air-conditioner_
LG Network Solution provides comfortable environment
and energy saving by optimum control of Air-conditioning system.
http
://w
ww
.lgea
irco
n.co
m
AC Smart•
PDI•
ACP & AC Manager•
BNU
Line up
Individual Controller
Wireless RemoteController
Wired RemoteController
PQWRHDF0
Simple
Standard
Deluxe
Central Controller
Simple Central Controller
Deluxe Central Controller
PC Central Controller
BMS
PQRCUCA0 (Simple)PQRCFCS0 (Simple for Hotel)
PQCSW502A2
PQCSS513A0
BNU-LW( ) GatewayEasy interface between BMS and LG air conditioner
• Independence of BMS under the standard BMS -Operation system based on Network Service
• 64 units ( A/C or Ventilator )• Self installation verification function using internet (web server included) - Setting gateway
- Diagnosis of communication status on LG Air-conditioner network
• Connection to remote total management System (LG system)PQNFB16A1
BNU-BN(BACnet) GatewayEasy interface between BMS and LG Air-conditioner
• Independence of BMS under the standard BMS - Operation system based on BACnet Service
• 256 units (A/C or Ventilator)• Self installation verification function using internet (web server included) - Setting gateway
- Diagnosis of communication status on LG Air-conditioner network
• Connection to remote total management System (LG system)PQNFB17B0
Electronic Accessory
PQNFB16A1( )
PQRCUDS0 (White) PQRCUDS0B (Blue) PQRCUDS0S (Silver)
PQCSB101S0 PQCSB101S0+PQCSC101S0(Function Controller)
PQNUD1S00(PDI)
PQCPA11A0E(Without IO)PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)
PQDSB(A) / PQDSB1 / PQDSBC (Dry Contact)
PQNFB17B0(BACnet)
PQRCUSA0(For Airconditioner)
PZRCUSB0(For Ventilation)
PQCSB101S0+PQCSD130A0(Scheduler)
PQCSW320A0E
For the small or midium sized buildings the 64 or 128 indoor units can be controlled and monitored by touch screen Central Controller. It’s possible to control and monitor the Air conditioning system through web access function, anywhere with PC.
PQCSW320A0E
Through embedded web control function in ACP one can control and monitor various functions of Air-conditioner such as Temperature setting, Schedule, Peak Power Control, etc. AC Manager is suitable for large site because AC Manager is the S/W that can control Max. 16 ACP (Max. 4,096 indoor units).
PDI (Power Distribution Indicator)For the multi indoor units connected to an outdoor unit, the individual unit and total system power consumption can be displayed on the device. This system can also be connected to a remote metering system.
PQNUD1S00
• Features - Accumulated total power consumption indicated
- Accumulated / Current power consumption of each indoor units indicated - Accumulated power consumption by month indicated
- Max connectable no. of indoor units : 48 indoor units
- 1 PDI per 1 outdoor unit
- Power failure-proof function : Data back up on EEPROM even if power turns off
- Connectable to PC based central controller
- Simple connection with the remote metering system (RS485 approach)
Control/Monitor New Function Upgrade Remote Access Various Controller Combination
Schedule
Peak Power ControlPower Proportional Distribution
Fire Alarm
Stand Alone Operation
- PQCPA11A0E / PQCPB11A0E- PQCSS520A0E
Korean reference site.
Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4,096 indoor units & Max.16 ACP
Max. 4,096 Indoor
AC ManagerACP
LG Air-conditioner_ LG Air-conditioner_
PQCPA11A0E / PQCPB11A0E
Max. no. of Indoor unitsControl / MonitoringSchedule ManagementLock functionTemperature range restrictionTemperature limit functionAuto Changeover functionHistory functionPeak controlPDI monitoringInterlocking functionPrinting function
256 Indoor units√√
TemperatureXXX
Monitoring
√Need of PDI
XX
PQCPAQQA0E+PQCSS520A0E PQCPBQQA0E+PQCSS520A0E
4,096 Indoor units (16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
X
System setting, History, PDI
4,096 indoor units(16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
Fire sensor, Door sensor Motion sensor...
System setting, History, PDI
Schedule ControlIt’s possible to set up various automatic operationschedule such as On_Off Control, Operation mode,Temperature setting, Fan speed.
History Function Zone ControlIt’s possible to control and monitor indoor units by Zone, Group or Unit
Lock Function Auto Changeover Temperature Limit FunctionThis function automatically starts and stops air-conditioner to prevent the building from freezing and overheating.
* Various Function
Operating and Error history is saved in AC Smart.So it helps to maintain the system more easily and quickly.
Various Lock functions help to restrict individual control of indoor units and manage power consumption of Air conditioner.
It is automatic operating mode change (cooling or heating) to maintain optimum room temperature, especially in season change period
*128 Indoor unit Expansion Kit: PQCSE440U0*DO Kit : PQNFP00T0