BM11S E-light IPLRF Laser PDT Machine

download BM11S E-light IPLRF Laser PDT Machine

of 21

description

With the continuous progress of science and technology, people gradually recognize the benefits of using a combination of a variety of beauty equipment, BM11S belongs to the multifunctional beauty machine, itself have E-light, iPL, RF and other functions,thus better to beautify the beauty of the people.

Transcript of BM11S E-light IPLRF Laser PDT Machine

  • User manual

    BM11S E-light+RF+LASERMultinational beauty machine

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine2

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine3

    Warning

    Dear user:Thanks for using our company's products, in order to fully make use of the products, wesincerely suggests follow:Please read the instruction in detail and keep it well for further reading andconsulting.Please follow the instruction to fit and operate the machine correctly.Please do not remove and change any accessories of the machine.It forbids others to open and remove the mainframe except the authorized peoplein the company.It forbids others to change and maintain the machine except the professionalpeople.Please contact us if there is any trouble during operation.

    This product does not belong to medical, please dont use for disease treatment!

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine4

    Contents

    Chapter 1 Product structure..................................................................................................................3

    Chapter 2 Accessories list.....................................................................................................................5

    Chapter 3 Product informaion.............................................................................................................. 5

    Chapter 4 Installation.............................................................................................................................. 6

    Chapter 5 Operation.................................................................................................................................8

    Chapter 6 Treatment..............................................................................................................................13

    6.1 Principle...........................................................................................................................................13

    6.2 Hand-piece and Application......................................................................................................... 13

    6.3 Attentions before the treatment...................................................................................................14

    6.4 Hair removal....................................................................................................................................15

    6.5 Skin rejuvenation........................................................................................................................... 16

    6.6 Pigmentation Therapy...................................................................................................................16

    6.7 Vascular Therapy...........................................................................................................................17

    6.8 Acne Therapy..................................................................................................................................18

    6.9 Wrinkle removal..............................................................................................................................18

    6.10 After Treatment Care...................................................................................................................19

    Chapter 7 Service manual....................................................................................................................19

    Chapter 8 Maintenance.........................................................................................................................20

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine5

    Caution

    1. When you received the new machine, please open it work one minute(enjoin from the machine working).2. Shut down the machine.3. Affusion water again4. Anew Open the machineWhen the water stream very well, then you can let the machine working.

    Chapter 1 Product structure

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine6

    Chapter 2 Accessories

    3.1 Application

    E light application:1. Therapy acne2. Reduction of vascular lesions3. Reduction of pigmented lesions4. Skin rejuvenation5. Permanent hair removal6. Wrinkle removal

    RF application:1. Skin lifting, tightening, andwhitening2. New collagen stimulation and production3. Removes fine lines and wrinkles4. Facial remodeling and body contouring5. Visibly minimize pores6. Circumference and cellulite reduction7. Body Shaping areas: abdomen, buttocks, thighs, neck, upperarms.

    Chapter 3 Product informaion

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine7

    Laser application:1. 1064nm Wavelength: Remove black and dark blue tattoo pigments, such as tattoos,eyebrows, dark color around the eyes, freckle, age spot etc.2. 532nm Wavelength: Remove red and brown tattoos and redmark.

    3.2 Specification:Wavelength 430/530/560/580/640-1200(nm)E light Handpiece 1 piece with 5 filtersRF handle 1 piece with 3 tipsLaser handle 1 piece with 2 tips(1064 and 532)Cooling system semiconductor+air+water+cooling gelIPL light energy 1-50(J/cm)Pulse Duration 1-10msPulse NO. 1--6Skin cooling -4c-10cDisplay 10.4"color touch screenOutput power 2000WRF frequency 10MHZLaser frequency 1-6HZVoltage 110V,50HZ or 220V,60HZMachine Size (L*W*H):42cm*38cm*90cmNet weight 56kgGross weight 91kgPackage size 65cm*63cm*111cmColor white & gray

    4.1 The process of installation includes:

    1. Unpacking the device.2. Staying the device for one day, in order to avoid destruction by high humidity duringlong distant transportation.3. Assembly of its components and ensure that all connections are firmly inplace.4. Fill the water tank with distilled water only.5. Connect the power supply.6. Switch on the device and test all functions / parameters of thesystem.

    Chapter 4 Installation

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine8

    4.2 Installation

    1) Installation treatment handpiece, please follow the figure,Plug the handpiececonnector firmly and properly to avoid the water circulationproblem.

    Figure 4.1

    1) Unscrew the Infusion hole cap and the overflow hole cap. (According to the following figure)

    Figure 4.2

    2) Infuse distilled water until the water overflow the overflow hole.

    Overflow hole

    Figure 4.3

    3) Ensure that the key is in the off position and that the emergency cut off button is not engaged. Ifit is engaged, release it by rotating the button towards the direction of the arrowindicator.

    4) Attach the power cord .5) Switch the circuit breaker to the On position.

    Figure 4.4

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine9

    6) Switch the unit on by inserting the key and turning it in a clockwise direction. At this time watercirculation and the cooling system startsautomatically.

    7) Observe whether water circulation runs well or not. After cooling system runs for at least 1minute, the water slide into the cooling system and then turn off thepower.

    8) Then switch on the system. It means you can fully assemble system with handpiece, screw onthe infusion cap.

    9) According to the following figure changeable of the various wavelength by 430,530,560,580,640~1200nm filter for spot size: 12*30mm.

    Figure 4.5

    10) When replace water1. Drain the remaining water which contains in the handle. Pay particular attention as not tospill any water on the electronic terminals. Wipe off any spilled water with a soft absorbentcloth.2. Replace water every 1-2 months.

    CAUTION

    1. Only distilled water is to be used in the cooling system.2. When using the system for the first time, rinse the cooling system with distilledwater.3. Ensure that the water level is adequate before treatment to prevent overheating.4. Distilled water is added periodically specially when working in warmer climates and

    when the treatment handpiece are changed often.5. Make sure that the treatment head is firmly secured .

    slot

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine10

    Chapter 5 Operation

    1Select Therapy ProgramTurn on the key switch of the machineenter Select Therapy Programs interface (as Fig.1).Select the treatment model to enter the interface of relevant treatment.

    Fig.1

    2Treatment Interface (E-light)

    WARNING

    1. WARNING: HIGH VOLTAGE: please ensure that all panels are secured prior tooperation.

    2. Place the treatment head on its support when on standby / simmermode.3. All personnel in the treatment room must wear the protective filteredglasses supplied.4. Make sure the patient is wearing the opaque protective goggles prior to treatment5. Avoid looking directly into the intense light during the treatmenteven if you are

    wearing the protection glasses.6. Do not point the treatment head outside the treatment field

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine11

    Fig.2

    After entering the interface of Treatment interface (as shown in Fig.2), press Ready to triggerthe handpiece. Capacitors will be charged automatically. Treatment can begin after chargingaccomplished. Press Standby to turn off the handpiece.

    Treatment modeTo indicate the current treatment mode.

    Treatment parametertreatment parameters recorded in treatment mode.

    State indicationTo indicate the current state and the flash numbers of the handpiece.

    Treatment record To indicate the current treatment record, different treatment records can berecorded to facilitate different patients. Treatment records can be altered, threechoices available.

    Cooling adjusting: To adjust the cooling temperature of the handpiece, five levels available. Themore blue snowflakes are, the cooler it will get. When the blue snowflakesdisappear, cooling stops.

    Return button: To return to the menu of Select Therapy Program not available when it is gray(during treatment).

    IPL energy: Toadjust the output energy of the handpiece. Energy value will be displayed on thescreen while adjusting, adjustable range: 1~50J/cm2. This setting can be donedirectly during treatment with or . to increase, to decreasepress and hold or to rapidly adjust the output energy.

    RF energy: To adjust the RF output energy, Energy value will be displayed on the screen whileadjusting, adjustable range: 1~20. This setting can be done directly duringtreatment with or . to increase, to decreasepress or to rapidly adjust the output energy.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine12

    The functions of IPL and RF can be turned on or off separately, but make sure that at least one ofthem is turned on. Pressing Ready cannot light the lamp when IPL function is off work.

    Status Prompted Window

    treatment parameter

    Adjust treatment parameter ,we can change the output energy of the treatment head, pulse duration,pulse number,thus can get different treatment effect. There are 8 items adjustable.

    RadioFrequency50~2500msUnit:50msThe greater the datathelonger the time of RF. 600ms is recommended

    Pulse number(1-6), 3 is recommend

    Pulse charge interval time(1-4s) 2S is recommended

    Press '' or '' to increase or decrease parameters

    First pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit.First pulse delay:To adjust delay between first pulse and next pulse.The range is 1-100ms,eachunit is 1ms.Second pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit.Second pulse delay:To adjust delay between second pulse and next pulse.The range is 1-100ms,each unit is 1ms.Repeat pulse duration:To adjust duration of third pulse and repeat pulse.The range is 1-10ms,every unit is 0.1ms.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine13

    RF

    Cooling

    Pulse output

    First Second Repeat First

    TreatmentPressing "Ready" button (green) to start treatment head and charge capacitors automatically, Startthe treatment after the capacitors finish charging. Press "Standby" button (red) to light up thetreatment head, system goes into standby mode. After finishing charging, please wait 10 seconds tostart treatment after cooling the treatment head. After pressing "ready" button, any buttons on thescreen no response.After releasing the "ready" button,other button can be adjusted At the end oftreatment, pressing"standby" button exit the treatment program and close the treatmenthead.

    Doing the treatment with RF should make the skin good contact with electrode and daubs cold gel.The energy should adjust from low to high and the time can not keep too long when the skincontacts with electrode to avoid scalding. The feeling of RF treatment is hot inner of the skin. If thetingle is strong, the reason could be that the cold gel is not enough and the skin is not goodcontacting with electrode. The way to solve the problem is to daubs cold gel again or adjustelectrode.

    RF treatment

    First Delay Second

    RF delay Dischargeinterval

    Pulse

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine14

    LASER treatment

    6.1 Principle

    E Light(IPL and RF)combines three advanced technologies: Bipolar Radio Frequency + IPL+Skin Contact Cooling.When the three are united in one treatment, wonderful treatmentexperience and result can beexpected. The energy of Radio Frequency can reach the middleand deep layer of the skin and heat up tissue, thus, lower energy is applied during the IPLtreatment. Uncomfortable feeling during the IPL treatment will be decreased significantly andbetter result can be expected. In addition, cooling system involved in E-light can also ease theuncomfortable feeling.The absorbing of the energy of radio frequency is not concerned withmelanin. So, the E-Lighttreatment can get good result on the soft or thin hair so as to decreasethe risk caused by traditional IPL treatment.

    6.2 Hand-piece and ApplicationWavelength Treatment

    430-1200nm Acne removal

    530-1200nm Freckles removal, Skin rejuvenation

    560-1200nm Whitening skin, Skin rejuvenation

    580-1200nm Vascular removal, fade melasma, skin rejuvenation

    640-1200nm Thick Hair removal

    frequency

    engery

    Chapter 6 Treatment

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine15

    The darker the skin 1.2.

    Decrease the fluenceIncrease the pulse delay (allow more cooling)

    The lighter the skin 1.2.

    Increase the fluenceDecrease the pulse delay

    The darker the hair / pigmented lesion 1.2.

    Decrease the fluenceIncrease the pulse delay (allow more cooling)

    The lighter the hair / pigmented lesion 1.2.

    Increase the fluenceDecrease the pulse delay

    Fine blood vessels 1.2.3.

    higher fluenceDecrease the pulse delayDecrease the pulse width

    Thicker blood vessels 1.2.

    Increase pulse delay (allow more cooling)Increase the pulse width

    The smaller the target size / lesion 1. Decrease pulse delayThe larger the target size / lesion 1. Increase pulse delay (allow more cooling)Bony prominences (forehead, malar area,shins)

    1. Decrease the fluence by 10-20%

    6.3 Attentions before the treatment

    1. Consultationpatients who have the following conditions but not limited should not take the treatment :A. Pregnant lady;B. Hypersusceptible to light or recently take medicines, such asacheomycin;C. Skin easy to scar;D. Diabetes (blisters maybe appear and not easy to heal up);E. Insolation in sunlight in recent 2 weeks;F.Heart disease;G. Epilepsy, and contagious skin disease, such as herpes;H. Skin cancer.

    2. PreparationWhen begin the treatment, take off the accessories such as watch, rings, bracelets orother metallic things which might be reflect light and cause danger during the treatment.Wipe off the cosmetic and clean the skin. Ware the goggles to protect the eyes of thepatients and the beautician.

    3. Sanitize the treatment head with alcoholized cottonballs.4. Clean the filters with alcoholized cottonballs.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine16

    6.4 Hair removal

    1.Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.2. Clear treatment area.3. Turn on machine ,put the 640nm or 690nm filter into the slot, select "hair removal",adjustthe parameter, set it to ready .

    4. Put cooling gel on treatment area about 2mm.5. Wear protect goggles for patient andoperator.6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have1/3 overlapping on treatment area.

    7. Wipe off cooling gel after treatment and clear treatment area with cooling water. Ifpatientsfeelwarm or hot, you may put ice bag on treatment area until heat disappear.

    8. Treatment Parameter:Woman:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Secondpulse

    Seconddelay

    Fluency(640nm filter)

    Fluency(690nmfilter)

    One 3 6.0 21 6.5 22 33 34

    Two 3 6.0 21 6.5 22 31 32

    Three 4 5.0 22 5.5 23 29 30

    Four 4 4.5 23 5.0 24 27 28

    Five 5 4.5 24 5.0 24 26 27

    Man:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Secondpulse

    Seconddelay

    Fluency(640nm filter)

    Fluency(690nm filter)

    One 3 5.5 20 6.0 21 32 33

    Two 3 5.5 20 6.0 21 30 31

    Three 4 5.0 21 5.5 22 28 29

    Four 4 4.5 22 5.0 23 26 27

    Five 5 4.5 23 5.0 24 25 26

    ** If application for removal of facial and upper lip area, the fluency should be reduced by 2to 3 Joules** If application for fine and thin hair, the fluency can be increased by 1 to 2 Joules,D1reduce by 1 to 2.

    ** If application for coarse and thick hair, the fluency can be reduced by 2 to 3 Joules ,D1increase by 1 to 2.

    ** If using spot size 15x50mm,the fluency should be increased by 2 to 3 Joules.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine17

    6.5 Skin rejuvenation

    1.Clear treatment area.2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust theparameter, set it to ready .

    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel inrefrigerator to keep temperature of gel during 0-4.4. Wear goggles for patient and operator5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.

    6. Wipe off cooling gel after treatment and clear treatment area with cooling water. Ifpatientsfeel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feelingdisappears.

    7.Treatment parameter:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Secondpulse

    Seconddelay

    Fluency (560nmfilter)

    One 3 5.0 20 5.5 21 24

    Two 3 5.0 20 5.5 21 23

    Three 4 4.5 21 5.0 22 22

    Four 4 4.0 22 4.5 23 21

    Five 5 4.0 23 4.5 24 19

    **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

    6.6 Pigmentation Therapy

    1.Clear treatment area.2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentationtherapy",adjust the parameter, set it to ready.

    3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel inrefrigerator to keep temperature of gel during 0-4.

    4. Wear goggles for patient and operator5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.

    6.Wipe off cooling gel after treatment and clear treatment area with cooling water. If patientsfeel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feelingDisappears.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine18

    7.Treatment parameter:Skin Type Pulses

    number

    Firstpulse

    Firstdelay

    Secondpulse

    Pulsesnumber

    Fluency(480nm filter)

    Fluency(530nm filter)

    One 3 5.0 20 5.5 21 28 29

    Two 3 5.0 20 5.5 21 27 28

    Three 4 4.5 21 5.0 22 26 27

    Four 4 4.0 22 4.5 23 25 26

    Five 5 4.0 23 4.5 24 24 25

    **If spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

    6.7 Vascular Therapy

    1. Clear treatment area.2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the

    parameter, set it to ready .Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in

    refrigerator to keep temperature of gel during 0-4.4.Wear goggles for patient and operator5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.

    Wipe off cooling gel after treatment and clear treatment area with cooling water. If patientsfeel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feelingdisappears.

    7.Treatment parameter:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Second

    pulse

    Pulsesnumbe

    r

    Fluency (580nmfilter)

    One 3 5.0 20 5.5 21 25Two 3 5.0 20 5.5 21 24Three 4 4.5 21 5.0 22 23Four 4 4.0 22 4.5 23 22Five 5 4.0 23 4.5 24 20

    ** If application for thin veins beneath the skin, the fluency can be reduced by1 to 2 Joules** If application for thick veins beneath the skin, the fluency can be increasedby 1 to 2 Joules** If using spot size 15x50mm, the fluency should be increased by 2 to 3Joules.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine19

    6.8 Acne Therapy

    1.Clear treatment area.2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust theparameter, set it to ready .

    Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel inrefrigerator to keep temperature of gel during 0-4.

    4.Wear goggles for patient and operator5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.

    Wipe off cooling gel after treatment and clear treatment area with cooling water. If patientsfeel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feelingdisappears.

    7.Treatment parameter:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Second

    pulse

    Pulsesnumbe

    r

    Fluency(430nmfilter)

    One 3 5.0 20 5.5 21 25Two 3 5.0 20 5.5 21 24Three 4 4.5 21 5.0 22 23Four 4 4.0 22 4.5 23 22Five 5 4.0 23 4.5 24 20

    **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

    6.9 Wrinkle removal

    1.Clear treatment area.2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust theparameter, set it to ready .

    Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel inrefrigerator to keep temperature of gel during 0-4.

    4.Wear goggles for patient and operator5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have1/3 overlapping on treatment area.

    Wipe off cooling gel after treatment and clear treatment area with cooling water. If patientsfeel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feelingDisappears.

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine20

    7.Treatment parameter:Skin Type Pulses

    numberFirstpulse

    Firstdelay

    Secondpulse

    Seconddelay

    Fluency (560nmfilter)

    One 3 5.0 20 5.5 21 24Two 3 5.0 20 5.5 21 23Three 4 4.5 21 5.0 22 22Four 4 4.0 22 4.5 23 21Five 5 4.0 23 4.5 24 19

    **If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

    6.10 After Treatment care

    Untoward Reactions:Pain, Scab formation, Pigmentation change, Scar formation, Swellingand Erythema.

    2. Protect treated skin from exposure to the sunlight or irradiation of ultraviolet radiation.3. DO NOT use irritative cosmetics within 24hours.4. Wash face with clean water, use moisture cosmetic when necessary.5. Dont eat piquant food.6. Take Vc or VE

    No power

    Check power cableCheck circuit breaker / fuseCheck key switchDisengage the emergency cut off switch by rotating towards

    the direction of the arrows indicated

    Notify your distributor

    Key pads are none responsive Please contact the dealer.

    System failed to initialize Not enough power, please check main power supply.Please contact the dealer.Malfunction of flash lamp onthe treatment head

    The treatment head / flash lamp has reached its maximumlife span (100,000) shots. Replace the treatment head

    The E-light treatment head is probably damaged, pleasechange the treatment head or contact the dealer.

    The treatment head is leaking The treatment head is probably damaged, please change thetreatment head or contact the dealer.

    The treatment handle is warm

    The system is designed for continued used for up four hoursin optimal environmental temperature and humidity.

    Always place the system on standby mode while awaitingtreatment. The system might have been left on for an extendedperiod. Turn the unit off, let it cool down for half an hour then re-start

    Contact the dealer.

    The power of The treatmenthead has weakened

    The treatment head has nearly reached its maximum lifespan (100,000 shots) the fluence can be adjusted by a few joulesto compensate.

    Chapter 7 Service manual

  • Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html E-light IPL beauty machine21

    Chapter 8 Maintenance

    1. Please change the distilled or pure water every 2-3 month to keep the water tank cleanand make sure water circulationwell.

    2. Please get water out from the unit before moving it for long distance, e.g. from one city toanother.

    3. Clean the main host.4.Clear Sapphire Crystal right after each treatment.5. Clear filter right after each treatment, and put into thebox.6 Replace the treatment hand-piece at a appropriate time(maximum life 100000 shots).

    WarningDear user:

    ApplicationSpecification:Installation1Select Therapy Program2Treatment Interface (E-light)Status Prompted WindowPulse outputTreatmentRF treatmentPrincipleHand-piece and ApplicationAttentions before the treatmentHair removalWoman:

    Skin rejuvenation**If using spot size 15x50mm, the fluency should b

    Pigmentation Therapy**If spot size 15x50mm, the fluency should be incr

    Vascular Therapy** If application for thin veins beneath the skin,

    Acne Therapy**If using spot size 15x50mm, the fluency should b

    Wrinkle removal**If using spot size 15x50mm, the fluency should b

    After Treatment care