Blackwater Septic tank Instruction Booklet

1
Septic Tank & Holding Tank Installation guide 3200L Septic Tank 3200L Holding Tank 3200L Septic Tank with Riser 3200L Holding Tank with Riser 4000L Septic Tank 4000L Holding Tank For more information on installation and technical specications, please visit     1     1     4     0     4      1     1     /     1     1 www.reln.com.au  Itemno. Qty Description  1 1 Holding Tank Base – factory assembled including factory tted reinforcing ring (item 12) and tank base extensions predrilled to nominal capacity of 4000L (items 16,17,19, 20, 21)  2 1 Tank Lid  3 1 Manhole Cover  4 2 Inspection Cover  Accessory Kit Contents  5 1 Inlet T-Junction  8 6 Manhole – Self Tapping Screws 10g 316 Stainless Steel  9 8  T-Junction Self T apping Screws 10g 316 Stainless Steel  10 8 Lid – Bolt,Washer,Nut M6 316 Stainless Steel  11 2 Bafe – Bolt,Washer,Nut M6 316 Stainless Steel  14 2 Bafe Extension – Bolt,Washer,Nut M6 316 Stainless Steel  22 8 Anchor Rope  23 1 Installation Instructions DimensionsNominal(mm)  A Overall tank height 2410  B Liquid depth level 1732  C Tank rim to invert of inlet 385  D Under roof to liquid level 540  E Maximum cover to inlet pipe 430  G Overall diameter 1998  H Tank base to ground level 2272  C apacity 4000L  Weight 159kg 4000L ho Ldi ng T ank Note: T G D B H A Ground Level Liquid Level Discharge pipe (by plumber) F C 4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser  Itemno. Qty Description  1 1 Holding Tank Base – factory assembled including factory tted reinforcing ring (item 12) and tank base extensions predrilled to nominal capacity of 4000L (items 16,17,19, 20, 21)  2 1 Tank Lid  3 1 Manhole Cover  4 2 Inspection Cover  Accessory Kit Contents  5 1 Inlet T-Junction  8 6 Manhole – Self Tapping Screws 10g 316 Stainless Steel  9 8  T-Junction Self T apping Screws 10g 316 Stainless Steel  10 8 Lid – Bolt,Washer,Nut M6 316 Stainless Steel  11 2 Bafe – Bolt,Washer,Nut M6 316 Stainless Steel  14 2 Bafe Extension – Bolt,Washer,Nut M6 316 Stainless Steel  22 8 Anchor Rope  23 1 Installation Instructions DimensionsNominal(mm)  A Overall tank height 2410  B Liquid depth level 1732  C Tank rim to invert of inlet 385  D Under roof to liquid level 540  E Maximum cover to inlet pipe 430  G Overall diameter 1998  H Tank base to ground level 2272  Capacity 4000L  Weight 159kg 4000L ho Ldi ng T ank Note: T G D B H A Ground Level Liquid Level Discharge pipe (by plumber) F C 4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser t Description  C T nk rim to invert of inlet 385 D Under roof to liquid level 540 E Maximu  t  t G Overall diameter 1998 H Tnk base to ground level 272 Capaci 4000L Weight 159kg Note:                                G Ground Level vel Liquid u  Le ve Dis D ha c rge pipe (by plumber) C 0  e  an  w i e 4000L Holdin T an  w/ R iser  Item no. Qty Description  1 1 Holding Tank Base – factory assembled including factory tted reinforcing ring (item 12) and tank base extensions predrilled to nominal capacity of 4000L (items 16,17,19, 20, 21)  2 1 Tank Lid  3 1 Manhole Cover  4 2 Inspection Cover  Accessory Kit Contents  5 1 Inlet T-Junction  8 6 Manhole Self Tapping Screws 10g 316 Stainless Steel  9 8 T-Junction Self Tapping Screws 10g 316 Stainless Steel  10 8 Lid – Bolt,Washer,Nut M6 316 Stainless Steel  11 2 Bafe Bolt,Washer,Nut M6 316 Stainless Steel  14 2 Bafe Extension Bolt,Washer,Nut M6 316 Stainless Steel  22 8 Anchor Rope  23 1 InstallationInstruction s Dimensions Nominal (mm)  A Overall tank height 2410  B Liquid depth level 1732  C Tank rim to invert of inlet 385  D Under roof to liquid level 540  E Maximum cover to inlet pipe 430  G Overall diameter 1998  H Tank base to ground level 2272  Capacity 4000L  Weight 159kg Note:  • Bafe and Outlet T-Junction not required in a holding tank. • Plumber to supply and install discharge pipe. • Holding tanks must only be pumped out half way • 4000L tank bases are supplied factory assembled • A riser must not be tted to 4000L tank G D B H A Ground Level Liquid Level Discharge pipe (by plumber) F C 4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser

description

Blackwater Instruction Booklet

Transcript of Blackwater Septic tank Instruction Booklet

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 1/6

Septic Tank & Holding Tank

Installation guide

3200L Septic Tank

3200L Holding Tank

3200L Septic Tank with Riser

3200L Holding Tank with Riser

4000L Septic Tank

4000L Holding Tank

For more information on installation and

technical specifications, please visit

    1    1    4    0    4 

    1    1    /    1    1

www.reln.com.au

  Itemno. Qty Description

  1 1 Holding Tank Base – factoryassembled including factory fittedreinforcing ring (item 12) and tankbase extensions predrilled to nominalcapacity of 4000L(items 16,17,19, 20, 21)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

  Accessory Kit Contents

  5 1 Inlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 8  T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  11 2 Baffle – Bolt,Washer,NutM6 316 Stainless Steel

  14 2 Baffle Extension – Bolt,Washer,NutM6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

DimensionsNominal(mm)

  A Overall tank height 2410

  B Liquid depth level 1732

  C Tank rim to invert of inlet 385

  D Under roof to liquid level 540  E Maximum cover to inlet pipe 430

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 4000L

  Weight 159kg

4000L ho Lding Tank 

Note:

T

G

D

B

HA

Ground Level

Liquid Level

Discharge pipe(by plumber)

F

C

4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser

  Itemno. Qty Description

  1 1 Holding Tank Base – factoryassembled including factory fittedreinforcing ring (item 12) and tankbase extensions predrilled to nominalcapacity of 4000L(items 16,17,19, 20, 21)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

  Accessory Kit Contents

  5 1 Inlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 8  T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  11 2 Baffle – Bolt,Washer,NutM6 316 Stainless Steel

  14 2 Baffle Extension – Bolt,Washer,NutM6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

DimensionsNominal(mm)

  A Overall tank height 2410

  B Liquid depth level 1732

  C Tank rim to invert of inlet 385

  D Under roof to liquid level 540

  E Maximum cover to inlet pipe 430

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 4000L

  Weight 159kg

4000L ho Lding Tank 

Note:

T

G

D

B

HA

Ground Level

Liquid Level

Discharge pipe(by plumber)

F

C

4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser

t Description

 

C T nk rim to invert of inlet 385

D Under roof to liquid level 540

E

Maximu   t   t 

G Overall diameter 1998

H T n k base to ground level 272

Capaci 4000L

Weight

159kg

Note:

 

    

   

    

   

    

 

     

G

Ground Levelvel

Liquidu  Le

ve

DisD ha

c rge pipe(by plumber)

C

0  

e  

an

 w

i

e

4000L Holdin

T

an  w/ R

iser

  Item no. Qty Description

  1 1 Holding Tank Base – factoryassembled including factory fittedreinforcing ring (item 12) and tankbase extensions predrilled to nominalcapacity of 4000L(items 16,17,19, 20, 21)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

  Accessory Kit Contents

  5 1 Inlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 8 T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  11 2 Baffle – Bolt,Washer,NutM6 316 Stainless Steel

  14 2 Baffle Extension – Bolt,Washer,NutM6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

Dimensions Nominal (mm)

  A Overall tank height 2410

  B Liquid depth level 1732

  C Tank rim to invert of inlet 385

  D Under roof to liquid level 540

  E Maximum cover to inlet pipe 430

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 4000L

  Weight 159kg

Note:  

• Baffle and Outlet T-Junction not required in a holding tank.

• Plumber to supply and install discharge pipe.

• Holding tanks must only be pumped out half way 

• 4000L tank bases are supplied factory assembled 

• A riser must not be fitted to 4000L tank 

G

D

B

HA

Ground Level

Liquid Level

Discharge pipe(by plumber)

F

C

4000L Septic Tank w/ Riser 4000L Holding Tank w/ Riser

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 2/6

1 Septic Tank & Holding Tank Installation Guide 2Septic Tank & Holding Tank Installation Guide 

1. Excavate site for installing tank in ground as per building code and local authority

requirements. Ensure adequate pipe fall to inlet of tank and from the tank outlet to

the transpiration bed or holding tank. Additionally, septic tanks are to be sited:

  • away from building foundations,

• away from traffic areas, both vehicular and pedestrian,

• away from or fenced off from animal stock pastures and areas.

2. Refer to the tank dimensions diagrams for correct levels.

  • 3200L Tanks need approx 2.0m deep excavation (Fig 1)

  • 4000L/3200L Tank complete with Riser need approx

2.4m deep excavation (Fig 2)

(exact depth will vary due to land fall and depth of bedding sand)

3. Do not bury tank lid. Manhole cover and inspection covers must be finished above

normal ground level to allow ongoing tank inspection and maintenance.

4. In the base of the excavation prepare a level 50mm bed of compacted sand

or soft compactable fill, free of large and/or sharp objects to allow levelling

of the tank base.

5. Carefully lower tank base into excavation - do not drop.

6. Align inlet and outlet with pipe trenches. Ensure tank base is level with lid off.

 

1. Where a baffle is required (check your state/local regulations), insert the

baffle as follows.

  • Position the baffle in the location lugs in the base of the tank

• In tank bases with a factory installed reinforced structural brace ring:

– Lower the baffle into the centre of the tank

– From inside the tank tilt the baffle so the bottom of the baffle is located

into the retaining pins in the base of the tank

– Push the baffle into a vertical position

– Ensure the baffle is seated on the reinforced structural brace ring and

firmly located in the base pins.

2. Drill and fix in marked position using supplied two (2) stainless steel bolts, nuts and

washers provided.

3. For 4000L Tanks, clip the additional baffle extension on top of the main baffle and

screw into place where indicated using two (2) stainless steel bolts, nuts and

washers supplied. (Fig 3)

(Fig 1)

(Fig 2)

(Fig 3)

1. On inlet side of tank base fit Inlet T-Junction. Apply silicone sealer to the flange of the T-Junction and secure with supplied four (4) stainless steel self-tapping

screws. (Fig 4 – shown for 3200L)

2. On outlet side of tank base fit Outlet T-Junction. Apply silicone sealer to the flange of the T-Junction and secure with supplied four (4) stainless steel

self-tapping screws. (Fig 5 – shown for 4000L)

1. Connect 100mm PVC sewer pipe into Inlet T-Junction. Glue inlet pipe to T-Junction with PVC plumbers glue.

2. Connect 100mm PVC sewer pipe into Outlet T-Junction. Glue outlet pipe to T-Junction with PVC plumbers glue.

1. Tie anchoring ropes (8) to the pre-drill ed lugs in the rim of the tank. Leave the looped end to hang free.

2. Place four durable anchoring beams (not included) through the looped ends of the ropes.

3. Anchor beams can be made from 100mm PVC sewer pipe (plumber to supply) and should be 2 metres long and positioned to exceed the tank’s extremities.

(Fig 6 & 7)

(Fig 4) (Fig 5)

RELN Septic Tanks and Holding Tanks are to be installed, by a licensed plumber, as per these instructions and local authority requirements.

RELN Septic Tanks and Holding Tanks are supplied with inlet and outlet holes drilled to the required location.

RELN Septic Tanks and Holding Tanks are approved to the requirements of the Australian Standard AS/NZ S1546.1:2008 On-site domestic wastewater treat ment

units – Septic tanks. Lic SMK1651

Approvals and additional information on Septic Tank operation and maintenance can be obtained from www.reln.com.au

(Fig 6) (Fig 7)

Approx

2.0m

Approx

2.4m

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 3/6

3 Septic Tank & Holding Tank Installation Guide 4Septic Tank & Holding Tank Installation Guide 

In sites where more fall is required from the exit point of the sewer line from the house to the septic tank, a riser can be used on a 3200L septic tank and holding

tank. This tank must be ordered complete with riser and will be supplied with a factory installed reinforced structural brace ring (Fig 8). The plumber installing

the septic tank is to assemble the ris er ring onto the tank base. Only one riser ri ng can be used. Riser rings must not be assembl ed to tank bases that do not

have a factory fitted reinforced structural brace ring.

1. Seal the riser ring to the tank with the provided black mastic sealing strip.

2. Cut four (4) strips 390mm long for the vertical sealing faces of the riser ring.

3. Apply a sealing strip to the vertical face ensure sealing strips cover the full length of

the vertical faces to provide a seal between each riser segment face. Remove paper

strip. Ensure a small protrusion of the seal at the bottom edge of the ring (3mm).

4. Bolt each riser segment panel together with the 12 supplied M8x40 stainless steel

bolt, washer and nuts. Use a washer on each side of the bolt. Securely tighten

bolts. This completes assembly of the ring segments.

5. On the tank base roll the remaining sealing strip into the channel lip rim of the tank

base, ensuring even coverage. Remov e paper strip.

6. The sealing strip is mouldable. Mould the ends of the sealing strip together to

create a single complete circular seal.

7. Identify the riser segment panel with the location lug. (Fig 9)

8. This riser segment and lug is positioned directly above the inlet pipe and aligns with

the lug in the tank base (Fig 10) and the inlet inspection point in the lid.

9. Place and align the assembled riser ring on top of the tank base.

10. Ensure correct positioning of riser ring dowel hole on the tank base

location dowel. (Fig 11)

11. With an M8 bit, drill and fix riser ring in position with 16 provided M8x50 stainless

steel bolts, washers and nuts. Use a washer on each side of the bolt. Securely

tighten bolts. Do not use self tapping screws!

        Ø       1       4       4

Ø600

HOLE FOR DISCHARGE

(BYPLUMBER)

4000L Septic Tanks and Holding Tanks are supplied with a fully assembled base

including the factory installed and sealed reinforced structural brace ring and the

additional base segments. (Plumber installs T-Junctions & Baffle).

(Fig 12)

1. Use supplied M6 Bolts to assemble lid to the assembled tank base (do not use self

tapping screws).

2. Apply a sealing bead of silicone in the top lip of the assembled tank base.

3. Place lid onto assembled tank base aligning the dowel pin in the tank base

assembly (Fig 9) with the corresponding dowel hole in the lid. This aligns the

inspection covers above the inlet and outlet pipes.

4. Drill and fix lid in position with the supplied eight (8) M6 x 30 stainless steel bolts,

washers and nuts.

5. Apply a sealing bead of silicone to lid recess for manhole cover.

6. Secure manhole cover in position with six (6) stainless steel self-tapping

screws provided.

7. Apply a sealing bead of silicone to lid and secure the two inspection covers.

1. Discharge pipe by plumber (Fig 13). Ensure discharge pipe hole does not cut

through lid strengthening ribs. (Fig 14)

2. Fasten discharge pipe to lid using 316 stainless steel screws.

3. Seal discharge pipe to lid with silicone.

4. Ensure maximum length of discharge pipe is half of tank depth. (Holding tanks must

only be pumped out half way.)

5. Discharge pipe connections must be positioned for easy pump-out vehicle access.

(Fig 13) (Fig 14)

(Fig 8)

Discharge pipe(by plumber)

Holding tanks must only bepumped out half way

(Fig 10)

(Fig 9)

(Fig 11)

Riser

Baffle

Reinforced Structural Brace Ring

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 4/6

5 Sept i c Tank & Hold i ng Tank Installat i on Gu i de 6Sept i c Tank & Hold i ng Tank Installat i on Gu i de 

1.  Secure the manhole cover then fill tank with water to outlet level. 

2.  After completely filling the tank with water, backfill around the tank w ith clean fill and compact thoroughly. Thorough compaction is required to secure

anchors and to ensure the backfill has the same dens ity as the surrounding ground.

3.  Compaction is important – ensure there are no large or sharp objects in backfill material.

4.  Ensure surface water run-off is directed away from pipe trenches and tank installation.

  All Dimensions (mm), Capaci ties and Weights Nominal  3200L 3200L / Riser 4000L

  A Overall tank height 2038 2410 2410

  B Liquid depth level 1427 1427 1732

  C Tank rim to invert of outlet 200 585 385

  D Under roof to liquid level 460 845 540

  E Maximum cover to inlet pipe 300 685 380

  F Maximum cover to outlet pipe 350 735 430

  G Overall diameter 1998 1998 1998

  H Tank base to ground level 1887 2272 2272

  Capacity 3200L 3200L 4000L

  Weight 122kg 159kg 159kg

  Weight including baffle 139kg 177kg 181kg

  Item no.  Qty Description

  1 1 Tank Base - factory predrilled tonominal capacity of 3200L

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspect ion Cover

  7 Optional Baffle - Optional at extra cost. Please refer your local authorityrequirements

  Accessory Ki t Contents

  5 1 Inlet T-Junction

  6 1 Outlet T-Junction

  8 6 Manhole Self Tapping Screws,10g 316 Stainless Steel

  9 8 T-Junction Self Tapping Screws,10g 316 Stainless Steel

  10 8 Lid Bolt, Washer, Nut,M6 316 Stainless Steel

  11 2 Baffle Bolt, Washer, Nut,M6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installat ion Instructions

All Dimensions (mm), Capaci ties and Weights Nominal

  A Overall tank height 2038

  B Liquid depth level 1427

  C Tank rim to invert of outlet 200

  D Under roof to liquid level 460

  E Maximum cover to inlet pipe 300

  F Maximum cover to outlet pipe 350

  G Overall diameter 1998

  H Tank base to ground level 1887

  Capacity 3200L

  Weight 122kg

  Weight including baffle 139kg

Ground Level

Liquid Level

FED

B

H

A

G

CGround Level

Liquid Level

FED

B

H

A

G

C

3200L Septic Tank 3200L Septic Tank w/Riser 4000L Septic Tank

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 5/67 Septic Tank & Holding Tank Installation Guide 8Septic Tank & Holding Tank Installation Guide 

  Item no. Qty Description

  1 1 Tank Base - factory predrilled tonominal capacity of 3200L

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

 Accessory Kit Contents

  5 1 Inlet T-Junction

  8 6 Manhole Self Tapping Screws,

10g 316 Stainless Steel

  9 8 T-Junction Self Tapping Screws,10g 316 Stainless Steel

  10 8 Lid Bolt, Washer, Nut,M6 316 Stainless Steel

  11 2 Baffle Bolt, Washer, Nut,M6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

All Dimensions (mm), Capacities and Weights Nominal

  A Overall tank height 2038

  B Liquid depth level 1427

  C Tank rim to invert of inlet 200

  D Under roof to liquid level 460

  E Maximum cover to inlet pipe 350

  G Overall diameter 1998

  H Tank base to ground level 1887

  Capacity 3200L

  Weight 122kg

3200L Septic Tank

Ground Level

3200L Holding Tank

Discharge pipe(by plumber)

Liquid Level

E

C

D

B

H

G

A

Note:  

• Baffle and Outlet T-Junction not required in a holding tank• Plumber to supply and install discharge pipe 

  Item no. Qty Description

  1 1 Septic Tank Base – factory predrilledto nominal capacity of 3200L includingfactory fitted reinforcing ring (item 12)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

  7 Optional Baffle – Optional at extra cost.Please refer to your local authorityrequirements

  Riser Ring Contents

  16 3 Riser Side Panels

  18 1 Riser Side Panel – Keyed

  Accessory Kit Contents

  5 1 Inlet T-Junction

  6 1 Outlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 8 T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  11 2 Baffle – Bolt,Washe r,NutM6 316 Stainless Steel

  20 16 Riser/Tank – Bolt, Washer, NutM8x50 316Stainless Steel

  21 12 Riser Ring Bolt, Washer, NutM8x25 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

All Dimensions (mm), Capacities and Weights Nominal

  A Overall tank height 2410

  B Liquid depth level 1427

  C Tank rim to invert of outlet 585

  D Under roof to liquid level 845

  E Maximum cover to inlet pipe 685

  F Maximum cover to outlet pipe 735

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 3200L

  Weight 159kg

  Weight including baffle 177kg

Note:  

• Only one riser can be used• Riser may only be fitted to tank with factory fitted reinforced structural

brace ring 

G

FED

B

HA

Ground Level

Liquid Level

C

7/17/2019 Blackwater Septic tank Instruction Booklet

http://slidepdf.com/reader/full/blackwater-septic-tank-instruction-booklet 6/69 Septic Tank & Holding Tank Installation Guide 10Septic Tank & Holding Tank Installation Guide 

  Item no. Qty Description

  1 1 Holding Tank Base – factory predrilledto nominal capacity of 3200L includingfactory fitted reinforcing ring (item 12)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

 Riser Ring Contents

  16 3 Riser Side Panel

  18 1 Riser Side Panel - Keyed

 Accessory Kit Contents

  5 1 Inlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 4 T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  20 16 Riser/Tank – Bolt, Washer, NutM8x50 316 Stainless Steel

  21 12 Riser Ring Bolt, Washer, NutM8x25 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

Dimensions Nominal (mm)  A Overall tank height 2410

  B Liquid depth level 1427

  C Tank rim to invert of inlet 585

  D Under roof to liquid level 845

  E Maximum cover to inlet pipe 735

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 3200L

  Weight 159kg

  Item no. Qty Description

  1 1 Septic Tank Base – factory assembledincluding factory fitted reinforcing ring(item 12) and tank base extensionspredrilled to nominal capacity of 4000L(items 15,16,17, 20, 21)

  2 1 Tank Lid

  3 1 Manhole Cover

  4 2 Inspection Cover

  7 + 13 Optional Baffle – Optional at extra cost.

Please refer to your local authorityrequirements

  Accessory Kit Contents

  5 1 Inlet T-Junction

  6 1 Outlet T-Junction

  8 6 Manhole – Self Tapping Screws10g 316 Stainless Steel

  9 8 T-Junction Self Tapping Screws10g 316 Stainless Steel

  10 8 Lid – Bolt,Washer,NutM6 316 Stainless Steel

  11 2 Baffle – Bolt,Washer,NutM6 316 Stainless Steel

  14 2 Baffle Extension – Bolt,Washer,NutM6 316 Stainless Steel

  22 8 Anchor Rope

  23 1 Installation Instructions

Dimensions Nominal (mm)

  A Overall tank height 2410

  B Liquid depth level 1732

  C Tank rim to invert of outlet 385

  D Under roof to liquid level 540

  E Maximum cover to inlet pipe 380

  F Maximum cover to outlet pipe 430

  G Overall diameter 1998

  H Tank base to ground level 2272

  Capacity 4000L

  Weight 159kg

  Weight including baffle 181kg

Note:  

• 4000L tank bases are supplied factory assembled(other than Baffles and T-Junctions) 

• A riser must not be fitted to 4000L tank 

Note:  

• Baffle and Outlet T-Junction not required in a holding tank 

• Only one riser can be used 

• Riser may only be fitted to tank base with factory fitted reinforced structural brace ring 

• Plumber to supply and install discharge pipe 

• Holding tanks must only be pumped out half way  G

FED

B

HA

Ground Level

Liquid Level

C

Ground Level

Liquid Level

3200L Septic Tank w/ Riser 3200L Holding Tank w/ Riser

Discharge pipe

(by plumber)

G

ED

B

HA

C