Biological Safety Cabinet Feature & HEPA-filter efficiency

Transcript of Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the...

Page 1: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Biological Safety CabinetFeature & HEPA-filter efficiency

Page 2: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

2

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////LAB FURNITURE SYSTEM

CHC LAB Co., Ltd., since the establishment in 1996, has been developing its

own technology as a manufacturer of laboratory furniture, fume hood and

laboratory equipment. After CHC LAB being registered as a SEFA (Scientific

Equipment and Furniture Association) member in 2007 for the first time

in Korea, Biological Safety Cabinet was certified by Korean Standard(KS) in

2008, and by NSF/ANSI standard 49 of USA in 2009, thus paved the way to

enter the world science equipment industry market.

CHC LAB has been supplied to various laboratories such as government-

invested organizations, education, pharmacy, medical, chemistry,

cosmetics, bio-engineering, and food area etc., based on the accumulated

technology power to perform the whole process of a laboratory layout,

design, production, installation and validation.

CHC LAB will grow as a specialized company of lab-safety technology

which is sustainable for more than a hundred years through the

development of design and eco-friendly technology that can lead the

world lab-safety technology.

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

COMPANYOVERVIEW

COMPANY OVERVIEW

Page 3: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

3

CHC LAB

Advanced Laboratory System

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

How can safety be provided?

How can reliable quality be assured?

Endless concerning about safety was the beginning of the CHC LAB.

The laboratory furniture, fume hood, biological safety cabinet of CHC

LAB which you will experience now will help you realize your research will

safely on the endless change and innovation

The technology and quality which have been cultivated by us together

with you with an unusual tenacity for safety will not be changed for more

than 100 years to be opened from now on.

We would like to ask you observe with constant interest and faith the next

100 years' journey of CHC LAB to be newly spread for the establishment

of the safety of researchers and laboratories.

CEOMESSAGE

CHC LAB

Advanced Laboratory System

Page 4: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience
Page 5: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

SAFETYSafety is the most important factor for laboratory equipment. CHC LAB's biological safety cabinets are

manufactured in full compliance with the standards of NSF/ANSI 49, EN12469, KS M10103, and guarantees safe research environments by supplying products with performance certifications.

Page 6: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

6

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

BiologicalSafety Cabinet

Wide intake grille and reserved air hole perfectly prevent the cross contamination of the inside and outside of a work table.

Wide armrest reduces the degree of fatigue of a researcher's wrists.

The work surface, which is easily disassembled from the equipment, is convenient for cleaning and maintenance.

User friendly intake grille & armrest Dished work surface

The sash alarm function is equipped for the safety of the researcher.The sash alarm will be activated in case sash level is out of preset level,e.g. 8 inches height.

Sash alarm for the convenience and safety

LCD digital display panel

HEPA filter

cabinet for the establishment of safe test environment

Page 7: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 7

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

The differential pressure gauge can cross check the abnormalities of the filter or air currents with the air velocity sensor through the real time checking of the negative pressure condition inside of the plenum.

One utility valve will be provided in standard, and up to four valves can be equipped.

Each one electrical receptacle with safety cover (220V/60Hz) will be provided at left and right side in standard. Electrical receptacles such as 115V/60Hz and 220V/50Hz are also available.

It prevents the direct inflow of the unpurified outside air into the inside of the chamber through the gap between the body and door sash when the front door is opened.

TM

The armrest of threshold structure makes the air current of the intake grille not to be disturbed by the researcher's arm, and perfectly blocks the UV light through the bottom crack of the door when the door is closed.

The inclined front structure is designed to reduce the glares occurring at time of work, or burden on the neck, arms etc., and enables the researcher's view to be closer to the work table.

A blower supplying stable air flow assures the performance of low noise and non-vibration by optimizing parts and balance, and reduces the energy consumption.

Ergonomic design

High performance blower

Easily extendable utility according to the environment and purpose of use

Non-filtered air protection hole

Threshold structure &UV light leak free guard

Threshold

Page 8: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

8

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

LCD digital display panel Useful functions

Biological Safety Cabinet

Control System

Paper Catch

Control of all operations of CleAir® BSC such as power on-off, blower on-off, lamp on-off, manager's password setting, timer setting

(including UV light), setting of warm up timer and post purge timer with the single control system.

Paper catch is designed to prevent the foreign substances dropped on the work tray from being sucked into the plenum.

Inflow air velocity, indoor temperature, electricity status etc. are displayed on the screen.

Filter exchange time is known through the air velocity setting, display, and alarm function, indoor temperature display and alarm function, manager mode setting on-off, electricity status display and alarm function, alarm timer and alarm mute, used time display and alarm setting of filter and UV lamp.

Warm up and post purge, which eliminate remaining air currentafter work, timer are available, password protection is availableat the operation of important functions such as manager mode,setting mode etc. in order to enhance the safety in equipmentoperation.

Blower and fluorescent lamp will be turned off automatically when the front window is closed.

Menu / CancleSet-up

Enter

Admin password setting

Warm up & Post purge setting UV & Alarm time setting

Filter expire setting

Timer setting

Page 9: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 9

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Biological Safety Cabinet

HEPA filter which eliminates the minute particles of 0.3㎛ by 99.995%

Filtering efficiency rate is higher than 99.995% based on the minute particle of 0.3㎛, and this filtering efficiency is enhanced at the particles below and above 0.3㎛ by three principles; interior impaction, interception and diffusion. (NSF 49, EN 12469 Standard on Filter Efficiency: >99.99% at 0.3㎛)

※ HEPA filter collection efficiency graph

HEPA filter

Filteration System

Advantages Description

Frame Extrudd and anodised aluminium

Gasket Polyurethane endless at inlet

Media Glass fiber paper

Separator Hot-melt beads

Sealant Polyurethane

MPPS efficiency H14≥ 99.995%

EN 1822 filter class H14, U15

Low pressure drop

Higher flow rate

Longer operating life

Individually tested according to EN 1822

Page 10: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

10

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Classification of Biological Safety Levels

Representitive microbe

ㆍBacillus anthracis ㆍBrucella abortus

ㆍYersinia pestis

Representitive microbe

ㆍEbola virus ㆍMarburg virus

ㆍLassa virus ㆍNipha virus

BSL

BSL BSL

BSL

Biological Safety Cabinet

CleAir® Biological Safety CabinetThe biological safety cabinet perfectly eliminates the possibility that the contaminated air which contains biological danger could be leaked out of the cabinet. It provides three protections.

It is an essential item for all laboratories where microorganisms of biological safety level 1 ~ 3 are treated,clinic pathologic test room, and bio medicines production site.

It is suitable for work involving biological agents not to cause disease in healthy adult humans, and of minimal potential hazard to laboratory personnel and the environment.

It is required for work with dangerous and exotic agents that pose a high individual risk of aerosol-transmitted laboratory infections, agents which cause severe to fatal disease in humans for which vaccines or other treatments are not available.

It is suitable for work involving biological agents to pose moderate potential hazard to personnel and the environment.It includes various bacteria and viruses that cause only mild disease to humans.Effective treatment and preventive measure is available.

It is required for work involving indigenous or exotic agents where the potential for infection is real and the disease may have serious or lethal consequences.It can cause severe to fatal disease in humans but for which treatments exist.

Representitive microbe

ㆍE.coli ㆍBacillus substilus

ㆍNaegleria gruberi

Representitive microbe

ㆍVibrio cholerae ㆍE.coli

ㆍHepatitis virus ㆍMeasles virus

1

3 4

2

Personnel protection from harmful agentsinside the cabinet.3

Product protection to avoid contamination orcross-contamination of the experiment.

Environment protection from the contaminates,contains inside the cabinet.

Protection

Page 11: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 11

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Class I Class II A2 Class II B2 Class III

※ In 2002, NSF verified the current classification for biological safety cabinet.

Biological Safety Cabinet Classifications

Biological Safety Cabinet Type

Biological Safety Cabinet Type List

Type Airflow Protection Biosafety level

Class I 100% Exhausted Personnel, Environment BSL 1

Class II

A230% Exhausted70% Recirculate

Personnel, EnvironmentProduct

BSL 1~3

B2 100% Exhausted BSL 1~3

Class III100% Exhausted

Glove boxBSL 1~3

Type Model number Certification

Class I CHC-100-03 / 04 / 05 / 06 -

Class II Type A2

CHC-111A2-03 / 04 / 05 / 06 -

CHC-222A2-03 / 04 / 05 / 06

CHC-777A2-03 / 04 / 05 / 06

Class II Type B2 CHC-888B2- 04 / 06

※CHC-111A2 series is produced in accordance with EN 12469 technical standards.※"★" is produced in accordance with the above-mentioned certification technical standards.

★ ★

Page 12: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

12

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Model No. General specification

CHC-100

03 04 05 06

Dimension

Exterior

W / mm 1040 1340 1650 1960

D / mm 777

H / mm 1300

Interior

'W / mm 919 1219 1529 1839

'D / mm 560

'H / mm 584

Color Gray

Door Basic - Tempered safety glass 5mm / Option - Acrylic panel door

Control panel LCD display panel

Required sash level 203mm (8inch)

Material

External SPCC / AL with epoxy powder coated

Chamber Stainless steel 304

Support stand Carbon steel pipes for ordinary piping

Performance

Certification X

Avg. inflow velocity (m/s) 0.4 (79fpm)

Avg. downflow velocity (m/s) -

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (db) < 65db(A)

Nominal Exhaust volume 269CMH 357CMH 447CMH 538CMH

Safety alarm system UV timer

Airflow

Room air

HEPA filtered air

Contaminated air under negative pressure

CleAir® BSC CHC-100

Biological Safety Cabinet | Class ICHC-100 of BSC Class I is a biological safety cabinet that is used to protect the researcher and research environment, and to treat the microorganism that is less dangerous.

※SPCC : Steel plate cold commercia

Page 13: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 13

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Model No. General specification

CHC-100

03 04 05 06

Electric

Power supply 110/220V, 50/60Hz (available)

FL lamp 36W x 1EA 36W x 2EA

UV lamp 20W x 1EA 30W x 1EA

Power receptacle 2EA

Exhaust

Duct (Ø) X

Hard exhaust connection X

Airthight damper X

Exhaust airflow sensor X

Etc Utility valve 1EA (vacuum)

Differential pressure gauge Option

Option

ㆍAdditional service valves (gas, air, water)

ㆍExhaust airflow sensor with monitor

ㆍSide window

ㆍElectric adjustable stand

Support frame Height/ mm

633

Caster Urethane 103

■ Support stand (Option)

‘H

‘D

H

DW‘W

Front view

Unit : mm

W : Width D : Depth H : Height

Side view

Page 14: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

14

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Airflow

Room air

HEPA filtered air

Contaminated air under positive pressure

Model No. General specification

CHC-111A2

04 05 06

Dimension

Exterior

W / mm 1340 1650 1960

D / mm 700

H / mm 1360

Interior

'W / mm 1220 1530 1840

'D / mm 539

'H / mm 581

Color Gray

Door Tempered safety glass 5mm

Control panel LCD display panel

Required sash level 203mm (8inch)

Material

External SPCC / AL with epoxy powder coated

Chamber Stainless steel 304

Support stand Carbon steel pipes for ordinary piping

Performance

Certification X

Avg. inflow velocity (m/s) 0.25 ~ 0.35

Avg. downflow velocity (m/s) 0.3 ~ 0.4

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (db) < 62db(A) < 63db(A)

Exhaust volume 312CMH 391CMH 471CMH

Safety alarm system UV timer, UV inter lock, UV safety sensor

CleAir® BSC CHC-111A2

Biological Safety Cabinet | Class II Type A2CHC-111 A2 is a BSC Class II A2 type in economic version, and is a biological safety cabinet that is used to protect the researcher, product and environment. 70 % of the airflow at work space is re-circulated through the HEPA filter, and 30% of it is exhausted to the outside through HEPA filter, and the polluted airflow is not leaked as perfectly surrounded by the negative pressure.

Contaminated air under negative pressure

※SPCC : Steel plate cold commercia

Page 15: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 15

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Model No. General specification

CHC-111A2

04 05 06

Electric

Power supply 110/220V, 50/60Hz (available)

FL lamp 36W x 1EA 36W x 2EA

UV lamp 30W x 1EA

Power receptacle 2EA

Exhaust

Duct (Ø) X

Exhaust connection Option

Air tight damper X

Exhaust airflow sensor X

Etc Utility valve 1EA (vacuum)

Differential pressure gauge O

Option

ㆍStainless steel IV bar

ㆍAdditional service valves (gas,air, water)

ㆍExhaust canopy connection

ㆍMotorized auto window

ㆍRemote-controlled service valve

ㆍSupport shelves for suction pump kit

ㆍStainless steel 316 internal material (excellent corrosion resistance)

W’W

Front view

Unit : mm

W : Width D : Depth H : Height

H

‘H

‘DD

Side view

Support frame Height/ mm

633

Caster Urethane 103

■ Support stand (Option)

Page 16: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

16

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Airflow

Room air

HEPA filtered air

Model No. General specification

CHC-222A2

03 04 05 06

Dimension

Exterior

W / mm 1060 1385 1690 1995

D / mm 810

H / mm 1590

Interior

'W / mm 925 1250 1555 1860

'D / mm 615

'H / mm 655

Color Gray

Door 6.38mm Laminated glass

Control panel LCD display panel

Required sash level 203mm (8inch)

Material

External SPCC / AL with epoxy powder coated

Chamber Stainless steel 304

Support stand Carbon steel pipes for ordinary piping

Performance

Certification - EN 12469, CE - EN 12469, CE

Avg. inflow velocity (m/s) 0.53 (105fpm)

Avg. downflow velocity (m/s) 0.35 (70fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (db) < 64db(A) < 65db(A)

Exhaust volume 358CMH 484CMH 602CMH 720CMH

Safety alarm system Warm up & Post purge, UV lamp interlock, UV timer, UV safety sensor, Door sensor, Alarm system

30% Exhaust

70% Recirculation

CleAir® BSC CHC-222A2

Biological Safety Cabinet | Class II Type A2CHC-222 A2 is a product of BSC Class II Type A2, which can protect effectively all of the researcher, product and environment. 70 % of the airflow at work space is re-circulated through the HEPA Filter, and 30% of it is exhausted to the outside through HEPA filter, and the polluted airflow is not leaked as perfectly surrounded by the negative pressure.Especially, the inclined front structure reduces the glares, or burden on the neck, arms etc.

Contaminated air under positive pressure

Contaminated air under negative pressure

※SPCC : Steel plate cold commercia

Page 17: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 17

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Model No. General specification

CHC-222A2

03 04 05 06

Electric

Power supply 110/220V, 50/60Hz (available)

FL lamp 36W x 2EA

UV lamp 30W x 1EA

Power receptacle 2EA

Exhaust

Duct (Ø) X

Exhaust connection Option

Air tight damper X

Exhaust airflow sensor X

Etc Utility valve 1EA (vacuum)

Differential pressure gauge O

Option

ㆍStainless steel IV bar

ㆍAdditional service valves (gas, air, water)

ㆍExhaust canopy connection

ㆍExhaust airflow sensor with monitor (required exhaust connection)

ㆍElectric adjustable stand

ㆍULPA filter

ㆍMotorized auto window

ㆍSupport shelves for suction pump kit

ㆍStainless steel 316 Internal material (excellent corrosion resistance)

ㆍRemote-controlled service valve

H

W D‘W

‘H

‘D

Front view

Unit : mm

W : Width D : Depth H : Height

Side view

Support frame Height/ mm

633

Caster Urethane 103

■ Support stand (Option)

Page 18: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

18

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Airflow

Room air

HEPA filtered air

30% Exhaust

Model No. General specification

CHC-777A2

03 04 05 06

Dimension

Exterior

W / mm 1060 1385 1690 1995

D / mm 810

H / mm 1590

Interior

'W / mm 925 1250 1555 1860

'D / mm 615

'H / mm 655

Color Gray

Door 6.38mm Laminated glass

Control panel LCD digital display panel

Required sash level 203mm (8inch)

Material

External SPCC / AL with epoxy powder coated

Chamber Stainless steel 304

Support stand Carbon steel pipes for ordinary piping

Performance

Certification NSF/ANSI 49, UL, KS M 10103 UL, KS M 10103 NSF/ANSI 49, UL KS M 10103

Avg. inflow velocity (m/s) 0.53 (105fpm)

Avg. downflow velocity (m/s) 0.35 (70fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (db) < 64db(A) < 65db(A)

Exhaust volume 358CMH 484CMH 602CMH 720CMH

Safety alarm system Warm up & Post purge, UV lamp interlock, UV timer, UV safety sensor, Door sensor, Alarm system

70% Recirculation

CleAir® BSC CHC-777A2

Biological Safety Cabinet | Class II Type A2CHC-777 A2 is a product of BSC Class II Type A2, which can protect effectively all of the researcher, product and environment. 70 % of the airflow at work space is re-circulated through the HEPA filter, and 30% of it is exhausted to the outside through HEPA filter, and the polluted airflow is not leaked as perfectly surrounded by the negative pressure.Especially, the inclined front structure reduces the glares, or burden on the neck, arms etc.

Contaminated air under positive pressure

Contaminated air under negative pressure

※SPCC : Steel plate cold commercia

Page 19: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 19

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

Model No. General specification

CHC-777A2

03 04 05 06

Electric

Power supply 110/220V, 50/60Hz (available)

FL lamp 36W x 2EA

UV lamp 30W x 1EA

Power receptacle 2EA

Exhaust

Duct (Ø) X

Exhaust connection Option

Air tight damper X

Exhaust airflow sensor O

Etc Utility valve 1EA (vacuum)

Differential pressure gauge O

Option

ㆍStainless steel IV bar

ㆍAdditional service valves (gas, air, water)

ㆍExhaust canopy connection

ㆍExhaust airflow sensor with monitor (required exhaust connection)

ㆍElectric adjustable stand

ㆍULPA filter

ㆍMotorized auto window

ㆍSupport shelves for suction pump kit

ㆍStainless steel 316 internal material (excellent corrosion resistance)

ㆍWired remote control

ㆍRemote-controlled service valve

H

W D‘W

‘H

‘D

Front view

Unit : mm

W : Width D : Depth H : Height

Side view

Support frame Height/ mm

633

Caster Urethane 103

■ Support stand (Option)

Page 20: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

BIOLOGICAL SAFETY CABINET

20

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Model No. General specification

CHC-888B2

04 06

Dimension

Exterior

W / mm 1385 1995

D / mm 810

H / mm 1825

Interior

'W / mm 1250 1860

'D / mm 615

'H / mm 655

Color Gray

Door 6.38mm Laminated glass

Control panel LCD digital display panel

Required sash level 203mm (8inch)

Material

External SPCC / AL with epoxy powder coated

Chamber Stainless steel 304

Support stand Carbon steel pipes for ordinary piping

Performance

Certification NSF/ANSI 49, UL

Avg. inflow velocity (m/s) 0.53 (105fpm)

Avg. downflow velocity (m/s) 0.30 (60fpm)

Filter efficeincy HEPA filter > 99.995% at 0.3㎛

Noise level (db) < 64db(A) < 65db(A)

Exhaust volume 1254CMH 1865CMH

Static duct pressure (mmWG) 51.3 60.1

Safety alarm system Warm up & Post purge, UV lamp interlock, UV timer, UV safety sensor, Door sensor

100%Exhaust

100% Exhaust

CleAir® BSC CHC-888B2

Biological Safety Cabinet | Class II Type B2CHC-888B2 is a product of BSC Class II Type B2, which protects all of the researcher, product and environment, and exhausts all of 100% of the air that passed the work space to the outside through the HEPA filter. Hard exhaust connection, airtight damper, exhaust airflow sensor will be provided in standard, and in case of the abnormal outside exhaust air volume, operation of the blower is immediately stopped for the safety.

Airflow

Room air

HEPA filtered air

Contaminated air under negative pressure

※SPCC : Steel plate cold commercia

Page 21: Biological Safety Cabinet - Thermolab · 2020. 3. 20. · CHC LAB Co., Ltd., since the establishment in 1996, ... fume hood, biological safety cabinet of CHC LAB which you will experience

Advanced Laboratory System 21

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// CHC LAB

460(+125)

W‘W ‘D

254.5

405

H‘

H

D

Front view

Unit : mm

W : Width D : Depth H : Height

Side view

Model No. General specification

CHC-888B2

04 06

Electric

Power supply 110/220V, 50/60Hz (available)

FL lamp 36W x 2EA

UV lamp 30W x 1EA

Power receptacle 2EA

Exhaust

Duct (Ø) 200 or 250

Hard exhaust connection O

Air tight damper O

Exhaust airflow sensor O

Etc Utility valve 1EA (vacuum)

Differential pressure gauge O

Option

ㆍStainless steel IV bar

ㆍAdditional service valves (gas, air, water)

ㆍULPA filter

ㆍMotorized auto window

ㆍRemote-controlled service valve

ㆍSupport shelves for suction pump kit

ㆍStainless steel 316 internal material (excellent corrosion resistance)

ㆍWired remote control Support frame Height/ mm

633

Caster Fixed foot (STS) 45

■ Support stand (Option)