Total Protection The specialized airflow system disperses air evenly over the supply and exhaust HEPA filters, minimizes vibration transfer, and eliminates potential leaks by surrounding the positive pressure chamber with negative pressure. The BSC cabinet design regulates air velocity through HEPA filters and apportions the downflow air across the work surface to create a containment zone. Negative pressure plenums and aerodynamically shaped cabinet surfaces capture airborne contaminants before they can enter the work area. High Performance Airflow Simplified Controls The microprocessor controller provides continuous supervision of all cabinet functions. Universal icon touchpad buttons simplify one- handed access to on/off and alarm/ monitoring system. An ergonomically sloped front cabinet profile places work in close proximity to the user, improving comfort and minimizing the stress of repetitive motion. Uniform interior lighting and a glare resistant front sash optimizes human interface. These features extend productivity and throughput performed on the work surface. Ease of Use Low Cost of Ownership The supply air plenum shape and an electronically commutated motor design with automatic feedback control work together to extend filter life. Front filter access permits authorized certifiers to change filters with safety and efficiency. The front-access supply and exhaust HEPA filters are designed to capture particulates with 99.99% efficiency for 0.3 microns. A closed-cell peripheral gasket surrounds the filter housing to prevent particulate bypass and escape to the work area or laboratory. High Capacity Filtration The Panasonic Class II, Type A2 Biological Safety Cabinet (BSC) offers a combination of cabinet design and filtration systems to protect person- nel, the work product and the environment from biological particulates. The BSC is engineered for work with low to moderate risk organisms that pose a biohazard concern. True laminar airflow with a constant face velocity airflow creates a performance envelope within and throughout the work surface to minimize or eliminate contamination. Class II, Type A2 MHE-N600A2-PA MHE-N600A2-PA Biological Safety Cabinet 6 ft. | 1.8 m

Transcript of Biological Safety Cabinet - Panasonic healthcare/.../BSC/...vF.pdf · The BSC cabinet design...

Page 1: Biological Safety Cabinet - Panasonic healthcare/.../BSC/...vF.pdf · The BSC cabinet design regulates ... handed access to on/off and alarm/ monitoring ... External depth is measured

Total Protection

The specialized airflow system disperses air evenly over the supply and exhaust HEPA filters, minimizes vibration transfer, and eliminates potential leaks by surrounding the positive pressure chamber with negative pressure.

The BSC cabinet design regulates air velocity through HEPA filters and apportions the downflow air across the work surface to create a containment zone. Negative pressure plenums and aerodynamically shaped cabinet surfaces capture airborne contaminants before they can enter the work area.

High Performance Airflow

Simplified Controls

The microprocessor controller provides continuous supervision of all cabinet functions. Universal icon touchpad buttons simplify one-handed access to on/off and alarm/monitoring system.

An ergonomically sloped front cabinet profile places work in close proximity to the user, improving comfort and minimizing the stress of repetitive motion. Uniform interior lighting and a glare resistant front sash optimizes human interface. These features extend productivity and throughput performed on the work surface.

Ease of Use

Low Cost of Ownership

The supply air plenum shape and an electronically commutated motor design with automatic feedback control work together to extend filter life. Front filter access permits authorized certifiers to change filters with safety and efficiency.

The front-access supply and exhaust HEPA filters are designed to capture particulates with 99.99% efficiency for 0.3 microns. A closed-cell peripheral gasket surrounds the filter housing to prevent particulate bypass and escape to the work area or laboratory.

High Capacity Filtration

The Panasonic Class II, Type A2 Biological Safety Cabinet (BSC) offers a combination of cabinet design and filtration systems to protect person-nel, the work product and the environment from biological particulates. The BSC is engineered for work with low to moderate risk organisms that pose a biohazard concern. True laminar airflow with a constant face velocity airflow creates a performance envelope within and throughout the work surface to minimize or eliminate contamination.

Class II, Type A2

MHE-N600A2-PA

MHE-N600A2-PA

Biological Safety Cabinet 6 ft. | 1.8 m

Page 2: Biological Safety Cabinet - Panasonic healthcare/.../BSC/...vF.pdf · The BSC cabinet design regulates ... handed access to on/off and alarm/ monitoring ... External depth is measured

Panasonic Healthcare Corporation of North America1300 Michael Drive, Suite A, Wood Dale, IL 60191 Toll Free USA (800) 858-8442, Fax (630) 238-0074 www.panasonic-healthcare.com/us/biomedical Printed in USA | 12 | 16 | 2016 | OW11023.10 | vf

6-foot Class II, Type A2 BSC

Design Features Optimize Workspace• A shaped arm rest in front of

a recessed airfoil maintains operator safety and eliminates eddy currents at the cabinet face.

• The recessed interior tray expands the work surface safe zone to bring work closer to the user.

• A spacious, frameless front sash expands the field of vision.

• The cabinet base is adjustable for sitting or bench work depending on preference. The base stand offers ample knee room at a sitting position.

Airflow Diagram

Contaminated Room AirContaminated Worksurface airHEPA Filtered AirAir Split

MHE-N600A2-PA

HEPA Filtered AIRContaminated Worksurface AirContaminated Room AirAir Split

Dimensions Unit : inch | mm

10254

70.4 | 1788

77.6 | 1972

24.6

| 62

5

251

30.4 | 772

26.5 | 673

32.2 | 817

58.9

| 14

9526

.5–3

2.5

673–

826

28.3

| 71

8

High efficiency motor/blower captures inflow air and passes recirculated air through HEPA supply filter over work sur-face. The air moving system apportions 30% of the air for safe, energy-efficient removal to the laboratory through HEPA exhaust filter.

18-24" viewing distance

view angle

Model Number MHE-N600A2-PA 6 foot (1.8 m)

External Dimensions (W × D × H) 1) nominal inches | mm 77.6 × 31.4 × 61.9 | 1972 × 799 × 1572

Internal Dimensions (W × D × H) 2) nominal inches | mm 70.4 × 25.8 × 28.5 | 1788 × 654 × 724

Net Weight lbs. | kg 640 | 290

Crated Shipping Weight 3) lbs. | kg 690 | 313

Performance

Personal Protection NSF/ANSI 49

Product Protection NSF/ANSI 49

NSF/ANSI 49 Classification Class II, Type A2

Construction

Style of Cabinet Benchtop/console with base stand/storage cabinet

Cabinet ConstructionPolished welded stainless steel 16/18 gauge,

Type 304 pressure tight design

Cabinet Depth with Armrest Removed inches | mm 31.4 | 799

Minimum Cabinet Height for Transport inches | mm 59.0 | 1499

Work Access Opening (standard height) inches | mm 10.0 | 254

Standard Inflow Velocity 2) FPM | m/s 105 | 0.53

Diffuser for Air Supply (Non-flammable, Metal) Included

HEPA Supply Filter 99.99% effective on 0.3 microns, neoprene gasket

HEPA Exhaust Filter 99.99% effective on 0.3 microns, neoprene gasket

Fumigation per NIH/NSF Procedures Yes

Gas Valve / Service Coupling (⅜" NPT) qty 1 right sidewall

Service Coupling (⅜" NPT) qty 1 right sidewall, 2 left sidewall

Duplex Outlet qty 2 backwall

Ultraviolet Light (included) qty 1 backwall

Viewing Window Opening Range: (tempered safety plate sliding glass)

inches | mm Fully closed to 21 | 533 open

Exhaust Opening inches | mm 10.0 | 254

Required Exhaust, Canopy Variable Flow Thimble (MHE-NAC11)

CFM | CMH 538-763 | 915-1297

Required Exhaust, Canopy Fixed Flow Thimble (MHE-NAC07)

CFM | CMH 634 | 1077

Duct Static Pressure inches | mm H2O 0.05-0.1 | 1.27-2.54

Heat Rejected, non-vented BTU/hour 1884

Heat Rejected, vented BTU/hour 198

Electrical and Noise Level

Electrical Classification UL / UL-C Listed

Power Supply 115V, 1Ø, NEMA 5-20P requires NEMA 5-20R receptacle

Frequency Hz 60

+Amps: Blower/Lights 4.8

Amps: Duplex 3

Amps: Rated 16

Power Cord qty 1 12 ft. (3.7 m),12 gauge - 3 Wire, 20A

Noise Level 4) dB (A) 63

Options

Gas Cocks ⅜" NPT qtyUp to 3 ea: 1 sidewall, 1 backwall,

1 left or right work surface

Sinks (standard or cup) Left or right work surface

1) External depth is measured with armrest removed and takes into account the control center. Height includes exhaust grill in the final measurement. 2) Measured at 10 inch (254) window height. Internal depth is measured with the armrest removed.3) Crated shipping weight does not include weight for accessories or options.4) Nominal level, measured 15 inches (381 mm) above the work tray and 12 inches (305 mm) in front of viewing window.