What is Biofeedback?A clinical technique that involves recording electrical activity generated in a muscle for diagnostic purposes
Utilizes an instrument that measures, processes & provides feedback reinforcing information via visual or auditory signals • Does not monitor actual response (strength of contraction)
but rather the conditions associated with the response
Not used as a modality like heat or cold, but can be used for rehabilitation & research purposes
Can be used to help regain function of a muscle that may have been lost
![Page 3: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/3.jpg)
Biofeedback Units4 types of Units: • Peripheral temperature,
• Finger Phototransmission,
• Electrical resistance units/ Skin Conductance Activity
• Electromyography (EMG),
EMG - most typically used form of biofeedback
Scale on unit can be both visual and audio
Measured in microvolts, 0-10 scale, or some form of pitch
![Page 4: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/4.jpg)
EMG & Other Units
http://www.dynatronics.com/catalog/dsp_product.cfm?ccats_id=D832477C-F4D0-11D5-AB25-0050DAB32CA6
http://www.bio-medical.com/results_igeneric.cfm?inventory__igeneric=emg
![Page 5: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/5.jpg)
Biofeedback UnitsPeripheral temperature units• Indirect measure of the diameter of peripheral
blood vessels• Easily seen in toes & fingers
• Variations in body reactions change temperature temperature indicates relaxed state temperature indicates stress, fear, anxiety
• Measured in degrees Fahrenheit
![Page 6: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/6.jpg)
Biofeedback UnitsFinger Phototransmission• Measured indirectly using a Photoplethysmograph
• Monitors amount of light reflected by subcutaneous tissues based on amount of blood flow
• As blood volume increases the amount of light detected decreases
• Monitor finger pulse
![Page 7: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/7.jpg)
Biofeedback UnitsElectrical resistance units/ Skin Conductance Activity• Measures amount of perspiration on the skin
• Sweat contains salt which increases electrical conductivity
• Passes a small current through the fingers (volar surface) and/or palm
• Measures impedance of electrical current
• Lie detector testing
![Page 8: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/8.jpg)
Lie Detectors
![Page 9: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/9.jpg)
Biofeedback UnitsElectromyographic (EMG)• Measures electrical activity in skeletal muscle• May be very simple to very complex• Take-home models
Electrodes – you will mostly see surface electrodes• Active electrodes:
• Detects electrical activity from muscle contraction & converts into visual or auditory signals
• Reference electrode (ground electrode): • Filters “noise” or unwanted electrical activity in the environment
(other electromagnetic energy); • Point of reference to compare the electrical activity recorded by
the active electrodes
![Page 10: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/10.jpg)
EMG Units
![Page 11: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/11.jpg)
Indications for EMG UseFacilitation for muscle reeducation
Restoration of neuromuscular function
Increase muscular strength
Promotion of relaxation of spasm
Reduction of muscle guarding
Assistance with pain control
Neurological Conditions (following stroke, spinal cord injury, cerebral palsy, incontinence)
![Page 12: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/12.jpg)
Advantages for using EMGProvides feedback with a chance to make appropriate small changes in performance that are immediately noted & rewarded
Patient learns early in rehab to do something for him/herself instead of relying on the athletic trainer
Proven to reduce myofascial pain, migraine & tension headache pain and stress reduction
With neuromuscular effects, biofeedback helps with input that is lost from receptor
![Page 13: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/13.jpg)
Contraindications
If movement of a joint or isometric contractions are contraindicated
Conditions in which muscle contractions might exacerbate the condition• Unhealed tendon grafts, avulsed tendons, 3rd
degree tears of muscle fibers
Unstable fractures, injury to joint structure, ligaments, capsule or articulating surfaces
![Page 14: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/14.jpg)
Patient Set-up & ApplicationShave area if applicable
Clean skin to remove all dirt, oil, lotion, etc.
Area may have to be mildly abraded if unit is sensitive
Secure electrodes OVER the muscle belly. The active electrodes MUST be on target area. Reference electrode may be secured anywhere on the body, but is usually in between the two active electrodes
Distance between active electrodes is usually close
![Page 15: Biofeedback](https://reader035.fdocuments.in/reader035/viewer/2022062313/558426b3d8b42a79568b49d2/html5/thumbnails/15.jpg)
Patient Set-up & Application
Plug electrode lead(s) into unit
Turn unit on
Adjust output to desired mode
THE PATIENT SHOULD NOT BE DISTRACTED BY OUTSIDE NOISES DURING SESSION.
Various protocols