BIO FABRIC CELERATOR

1
FOOTPRINT:960 sq ft SECTION FOR PRESBY SYSTEM H20 LOADING (RESERVE AREA) NOTES: 1 STABILIZATION FABRIC TO BE MIRAFI 600X OR EQUAL 2 INSTALLATION/RETROFIT TO BE DONE BY A PRESBY QUALIFIED AND LICENSED CONTRACTOR. NOTES: 1. VENTING IS ESTABLISHED THROUGH SUCTION (CHIMNEY EFFECT) CREATED BY THE DRAW OF AIR FROM THE HIGH VENT, WHICH DRAWS AIR INTO THE LOW VENT AT THE LEACH FIELD THEN THROUGH THE SEPTIC TANK AND EXHAUSTED THROUGH THE (HIGH) ROOF VENT. 2. REFER TO TYPICAL DISPOSAL BED DETAIL AND PROFILE FOR SPECIFIC ELEVATIONS. 3. ROOF VENT FOR NEW HOUSE TO BE 3" MINIMUM IN ACCORDANCE WITH PRESBY SYSTEM REQUIREMENTS. PRESBY ADVANCED ENVIRO-SEPTIC SYSTEM DETAILS NTS LOW VENT (AIR INLET) 3" MIN. ROOF VENT (HIGH VENT, EXHAUST - CREATES SUCTION) PVC SANITARY TEE INLET BAFFLE WITH OPEN TOP PVC BAFFLE NOTES: 1. EFFLUENT FILTER (IF USED) MUST BE PROPERLY MAINTAINED TO ENSURE ADEQUATE AIR FLOW. 2. DO NOT USE CHARCOAL FILTERS ON VENTS. THEY CAN RESTRICT AIR FLOW. GRAVITY SYSTEM AIR FLOW PVC SANITARY TEE OUTLET BAFFLE WITH OPEN TOP NTS 10' MIN. BETWEEN HIGH AND LOW VENTS 3" MIN 12" 6" MIN 4" MIN SYSTEM SAND SYSTEM SAND (C-33 SAND) 1' MIN. PIPE BED WIDTH SAND BED WIDTH PLACE MIN. 3" OF SYSTEM SAND OVER AES PIPES. PLACE NO BARRIERS OVER THE SYSTEM SAND. VENT TO 3' ABOVE FINAL GRADE CROWN TO SHED WATER 1' MIN. SKIMMER TABS CROSS SECTION EFFLUENT SCUM SLUDGE BIO-ACCELERATOR FABRIC (AES) ONLY GEO-TEXTILE FABRIC COARSE FIBERS (AES & ES ONLY) RIDGES ® C I R B A F R O T A R E L E C C A - O I B AIR SPACE ® SEWN SEAM (ALWAYS UP) C:\RR Proj\Proj\Mt Olive\Chmiel 24 Camp Pulaski Road\Septic Oct 12 2021.dwg, 10/26/2021 11:03:48 AM, DWG To PDF.pc3

Transcript of BIO FABRIC CELERATOR

FOOTPRINT:960 sq ft

SECTION FOR PRESBY SYSTEM H20 LOADING (RESERVE AREA)

NOTES:

1 STABILIZATION FABRIC TO BE MIRAFI 600X OR EQUAL

2 INSTALLATION/RETROFIT TO BE DONE BY A PRESBY QUALIFIED

AND LICENSED CONTRACTOR.

NOTES:1. VENTING IS ESTABLISHED THROUGH SUCTION (CHIMNEY EFFECT) CREATED BY THE

DRAW OF AIR FROM THE HIGH VENT, WHICH DRAWS AIR INTO THE LOW VENT AT THELEACH FIELD THEN THROUGH THE SEPTIC TANK AND EXHAUSTED THROUGH THE(HIGH) ROOF VENT.

2. REFER TO TYPICAL DISPOSAL BED DETAIL AND PROFILE FOR SPECIFIC ELEVATIONS.3. ROOF VENT FOR NEW HOUSE TO BE 3" MINIMUM IN ACCORDANCE WITH PRESBY

SYSTEM REQUIREMENTS.

PRESBY ADVANCED ENVIRO-SEPTIC SYSTEM DETAILSNTS

LOW VENT(AIR INLET)

3" MIN. ROOF VENT (HIGH VENT,EXHAUST - CREATES SUCTION)

PVC SANITARY TEEINLET BAFFLE

WITH OPEN TOP

PVC BAFFLE

NOTES:1. EFFLUENT FILTER (IF USED) MUST BE PROPERLY MAINTAINED TO ENSURE ADEQUATE AIR FLOW.

2. DO NOT USE CHARCOAL FILTERS ON VENTS. THEY CAN RESTRICT AIR FLOW.

GRAVITY SYSTEM AIR FLOW

PVC SANITARY TEE OUTLETBAFFLE WITH OPEN TOP

NTS

10

' MIN

. BE

TW

EE

N H

IGH

AN

D L

OW

VE

NT

S

3" MIN

12"

6" MIN

4" MINSYSTEM SAND

SYSTEM SAND (C-33 SAND)

1' MIN.PIPE BED WIDTH

SAND BED WIDTH

PLACE MIN. 3" OF SYSTEM SAND OVERAES PIPES. PLACE NO BARRIERS

OVER THE SYSTEM SAND.VENT TO 3' ABOVE

FINAL GRADE

CROWN TOSHED WATER

1' MIN.

SKIMMER TABS

CROSS SECTION

EFFLUENT

SCUM

SLUDGE

BIO-ACCELERATORFABRIC (AES) ONLY

GEO-TEXTILEFABRIC

COARSE FIBERS(AES & ES ONLY)

RIDGES

®

CIRBAFROTARELECCA-OIB

AIR SPACE

®

SEWN SEAM(ALWAYS UP)

C:\R

R P

ro

j\P

ro

j\M

t O

live\C

hm

iel 24 C

am

p P

ulaski R

oad

\Sep

tic O

ct 12 2021.d

wg

, 10/26/2021 11:03:48 A

M, D

WG

To

P

DF.p

c3

AutoCAD SHX Text
CENTERLINE OF PSE & G TOWERS
AutoCAD SHX Text
1 STORY BRICK AND FRAME DWELLING
AutoCAD SHX Text
TAX BLOCK 400 TAX LOT 5
AutoCAD SHX Text
N 01°35'40" E
AutoCAD SHX Text
210.54'
AutoCAD SHX Text
S 79°10'22" E
AutoCAD SHX Text
291.22'
AutoCAD SHX Text
S 40°36'03" E
AutoCAD SHX Text
96.20'
AutoCAD SHX Text
S 56°59'55" W
AutoCAD SHX Text
101.28'
AutoCAD SHX Text
N 66°18'13" E
AutoCAD SHX Text
81.99'
AutoCAD SHX Text
N 55°47'30" W
AutoCAD SHX Text
121.05'
AutoCAD SHX Text
N 43°09'16" W
AutoCAD SHX Text
168.84'
AutoCAD SHX Text
N 78°25'05" W
AutoCAD SHX Text
293.19'
AutoCAD SHX Text
SHED
AutoCAD SHX Text
WOOD BRIDGE
AutoCAD SHX Text
STREAM
AutoCAD SHX Text
STREAM
AutoCAD SHX Text
PSE & G CO. UTILITY R.O.W.
AutoCAD SHX Text
IRON PIPE FOUND
AutoCAD SHX Text
IRON PIPE FOUND
AutoCAD SHX Text
IRON PIPE FOUND
AutoCAD SHX Text
WELL
AutoCAD SHX Text
DECK ABOVE
AutoCAD SHX Text
CONCRETE WALKWAY
AutoCAD SHX Text
FFE: 991.79'
AutoCAD SHX Text
GFE: 991.50
AutoCAD SHX Text
ASPHALT DRIVEWAY
AutoCAD SHX Text
GRAVEL DRIVE
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
BM AT PK ELEVATION: 1003.61
AutoCAD SHX Text
PER DEED BOOK 2928, PG 127
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
SCALE: 1'=30"
AutoCAD SHX Text
1004
AutoCAD SHX Text
1004
AutoCAD SHX Text
1002
AutoCAD SHX Text
1002
AutoCAD SHX Text
1000
AutoCAD SHX Text
1000
AutoCAD SHX Text
998
AutoCAD SHX Text
998
AutoCAD SHX Text
996
AutoCAD SHX Text
996
AutoCAD SHX Text
994
AutoCAD SHX Text
994
AutoCAD SHX Text
992
AutoCAD SHX Text
992
AutoCAD SHX Text
990
AutoCAD SHX Text
990
AutoCAD SHX Text
990
AutoCAD SHX Text
990
AutoCAD SHX Text
988
AutoCAD SHX Text
988
AutoCAD SHX Text
988
AutoCAD SHX Text
988
AutoCAD SHX Text
986
AutoCAD SHX Text
986
AutoCAD SHX Text
986
AutoCAD SHX Text
986
AutoCAD SHX Text
984
AutoCAD SHX Text
984
AutoCAD SHX Text
984
AutoCAD SHX Text
984
AutoCAD SHX Text
982
AutoCAD SHX Text
982
AutoCAD SHX Text
980
AutoCAD SHX Text
980
AutoCAD SHX Text
978
AutoCAD SHX Text
978
AutoCAD SHX Text
976
AutoCAD SHX Text
976
AutoCAD SHX Text
974
AutoCAD SHX Text
974
AutoCAD SHX Text
972
AutoCAD SHX Text
972
AutoCAD SHX Text
970
AutoCAD SHX Text
970
AutoCAD SHX Text
968
AutoCAD SHX Text
968
AutoCAD SHX Text
966
AutoCAD SHX Text
966
AutoCAD SHX Text
964
AutoCAD SHX Text
964
AutoCAD SHX Text
X 990'
AutoCAD SHX Text
T-1
AutoCAD SHX Text
NEW 1,000 GALLON SEPTIC TANK/APPROXIMATE EXISTING TANK (EXISTING TANK TO BE REMOVED SEE NOTE 22)
AutoCAD SHX Text
NEW DISPOSAL FIELD 18'x36' (648 SF) (SEE DISPOSAL FIELD PLAN)
AutoCAD SHX Text
SILT FENCE
AutoCAD SHX Text
RR TIE WALL
AutoCAD SHX Text
T-2
AutoCAD SHX Text
100% RESERVE AREA
AutoCAD SHX Text
10 LF 4" PVC @ S=0.02 FT/FT
AutoCAD SHX Text
12 LF 4" PVC @ S=0.02 FT/FT
AutoCAD SHX Text
25' TO T.O.B.
AutoCAD SHX Text
EXISTING HOUSE TO REMAIN
AutoCAD SHX Text
EXISTING WELL TO REMAIN
AutoCAD SHX Text
100'
AutoCAD SHX Text
SYSTEM INTAKE VENT
AutoCAD SHX Text
150'
AutoCAD SHX Text
WOODED
AutoCAD SHX Text
WOODED
AutoCAD SHX Text
APPROX. HOUSE
AutoCAD SHX Text
WOODED
AutoCAD SHX Text
WOODED
AutoCAD SHX Text
150'
AutoCAD SHX Text
150'
AutoCAD SHX Text
WOODED
AutoCAD SHX Text
CAMP PULASKI RD
AutoCAD SHX Text
150'
AutoCAD SHX Text
NEW GAZEEBO - RETEST AIR VENTS AS REQUIRED
AutoCAD SHX Text
STAKE OUT PROPERTY LINE REMOVE PORTIONS OF DRIVEWAY ON ADJACENT PROPERTY
AutoCAD SHX Text
PROPOSED GARAGE (SLAB ON GRADE)
AutoCAD SHX Text
SEE PAVEMENT SECTION FOR INSTALLATION OF PRESBY SYSTEM UNDER DRIVEWAY
AutoCAD SHX Text
REMOVE SHED
AutoCAD SHX Text
PROPOSED DRIVEWAY
AutoCAD SHX Text
HIGH VENT
AutoCAD SHX Text
SECURELY FASTENED TO THE POSTS USING A SYSTEM CONSISTING OF METAL
AutoCAD SHX Text
FASTENERS (NAILS OR STAPLES) AND A HIGH STRENGTH REINFORCEMENT MATERIAL
AutoCAD SHX Text
THE GEOTEXTILE FABRIC. THE FASTENING SYSTEM SHALL RESIST TEARING AWAY FROM
AutoCAD SHX Text
THE POST. THE FABRIC SHALL INCORPORATE A DRAWSTRING IN THE PORTION OF THE
AutoCAD SHX Text
(NYLON WEBBING, GROMMETS, WASHERS ETC.) PLACED BETWEEN THE FASTENER AND
AutoCAD SHX Text
FENCE FOR ADDED STRENGTH.
AutoCAD SHX Text
%%USILT FENCE DETAIL
AutoCAD SHX Text
3. A GEOTEXTILE FABRIC, RECOMMENDED FOR SUCH USE BY THE MANUFACTURER,
AutoCAD SHX Text
SHALL BE BURIED AT LEAST 6 INCHES DEEP IN THE GROUND. THE FABRIC
AutoCAD SHX Text
SHALL EXTEND AT LEAST 2 FEET ABOVE THE GROUND. THE FABRIC MUST BE
AutoCAD SHX Text
1. FENCE POSTS SHALL BE SPACED 8 FT. CENTER-TO-CENTER OR CLOSER.
AutoCAD SHX Text
THEY SHALL EXTEND AT LEAST 2 FEET INTO THE GROUND AND EXTEND
AutoCAD SHX Text
AT LEAST 2 FEET ABOVE GROUND. POSTS SHALL BE CONSTRUCTED OF
AutoCAD SHX Text
HARDWOOD WITH A MINIMUM DIAMETER THICKNESS OF 1 1/2 INCHES.
AutoCAD SHX Text
2. A METAL FENCE WITH 6 INCH OR SMALLER OPENINGS AND AT LEAST
AutoCAD SHX Text
2 FEET HIGH MAY BE UTILIZED, FASTENED TO THE FENCE POSTS, TO
AutoCAD SHX Text
PROVIDE REINFORCEMENT AND SUPPORT TO THE GEOTEXTILE FABRIC
AutoCAD SHX Text
WHERE SPACE FOR OTHER PRACTICES IS LIMITED AND HEAVY SEDIMENT
AutoCAD SHX Text
LOADING IS EXPECTED.
AutoCAD SHX Text
REQUIREMENTS FOR SILT FENCE:
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
DIG 6" DEEP TRENCH,
AutoCAD SHX Text
BURY BOTTOM FLAP,
AutoCAD SHX Text
TAMP IN PLACE
AutoCAD SHX Text
2'-0" (MIN.)
AutoCAD SHX Text
6"
AutoCAD SHX Text
6"
AutoCAD SHX Text
FENCE POST
AutoCAD SHX Text
(SPACING 8'-0" O.C.)
AutoCAD SHX Text
FASTENER AND FABRIC
AutoCAD SHX Text
FABRIC SECURED TO POST
AutoCAD SHX Text
W/METAL FASTENERS AND
AutoCAD SHX Text
REINFORCEMENT BETWEEN
AutoCAD SHX Text
DRAWSTRING RUNNING THROUGH
AutoCAD SHX Text
FABRIC ALONG TOP OF FENCE
AutoCAD SHX Text
ACCUMULATION
AutoCAD SHX Text
SILT
AutoCAD SHX Text
2'-0" (MIN)
AutoCAD SHX Text
1.0' EDGE SPACING ALL AROUND
AutoCAD SHX Text
INSPECTION PORT, 4" PERFORATED PIPE W/ SCREW OFF CAP EXTEND PIPE FROM INFILTRATION LEVEL TO GRADE (TYP. OF 4)
AutoCAD SHX Text
NEW DISPOSAL FIELD 36' x 18' AREA = 648 SF
AutoCAD SHX Text
4" DIA. PVC FM FROM SEPTIC TANK
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
%%UDISPOSAL FIELD PLAN
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
%%USEPTIC SYSTEM PROFILE
AutoCAD SHX Text
DISPOSAL FIELD 12" PRESBY PIPE @ 3.75' O.C. PIPE INV. = 980.3
AutoCAD SHX Text
3.75' (TYP.)
AutoCAD SHX Text
RAISED CONNECTION (SEE DETAIL)
AutoCAD SHX Text
5 ROWS X 34 LF. PER ROW OF 12" PRESBY AES PIPE INSTALLED PER PRESBY ENVIRONMENTAL, INC. SPECIFICATIONS
AutoCAD SHX Text
FINAL GRADE 982.2 +/-
AutoCAD SHX Text
NEW 1,000 GAL. SEPTIC TANK INV. IN = 980.8 INV. OUT = 980.5
AutoCAD SHX Text
36'
AutoCAD SHX Text
18'
AutoCAD SHX Text
12 LF OF 4" SC. 40PVC @ S=0.02 FT/FT
AutoCAD SHX Text
FINAL GRADE 982.5 +/-
AutoCAD SHX Text
SYSTEM VENT (SEE DETAIL)
AutoCAD SHX Text
10 LF 4" PVC @ S=0.02 FT/FT
AutoCAD SHX Text
4" INV. OUT 981.0
AutoCAD SHX Text
EXISTING HOUSE FIN. FLOOR 983.2
AutoCAD SHX Text
SOIL DATA SOIL LOG: T-1 (EL. 981.5) 0-6" TOPSOIL 6"-96" TAN BROWN SANDY LOAM SUB-ANGULAR BLOCKY, DRY, LOOSE, 5% COBBLES, (10YR 7 / 6) NO MOTTLES OR GWT LEDGE AT 96" (EL. 973.5) T-2 (EL. 980.5) 0-6" TOPSOIL 6"-96" TAN BROWN SANDY LOAM SUB-ANGULAR BLOCKY, DRY, LOOSE, 5% COBBLES, (10YR 7 / 6) NO MOTTLES OR GWT LEDGE AT 96" (EL. 972.5) SOIL SUITABILITY: IISr SOIL PERMEABILITY: 6-20 MIN/IN (K4 IMPORTED FILL) SOIL SAMPLE AT 48"-60" FROM T-1 (K-3 PER LAB TESTING) SOIL LOGS BY ROBERT ROSELLI, PE AND SUSAN DOWNER, MT. OLIVE HEALTH DEPARTMENT MARCH 29, 2019
AutoCAD SHX Text
DESIGN DATA DAILY FLOW (NJAC 7:9A-7.4) NUMBER OF HOUSE BEDROOMS = 3 DESIGN FLOW = 200 GPD (FIRST BR) 150 GPD PER BR AFTER DESIGN FLOW = 200 + 2(150) = 500 GPD DISPOSAL FIELD AREA (NJAC 7:9A-10.2) PERMEABILITY = 6-20 MIN/IN (AT LEVEL OF INFILTRATION) REQUIRED FIELD AREA = 1.233 SF/GPD FOR ALTERNATIVE SYSTEM (TABLE 10.2(e)) REQUIRED FIELD AREA = 500 GPD * 1.233 SF/GPD = 617 SF AREA PROVIDED = 36' X 18' = 648 SF PER PRESBY MANUAL PIPE LOADING RATE=3 GPD/LF PIPE= 500 / 3 = 167 LF PROVIDE 5 ROWS * 34' PER ROW = 170 LF SETPIC TANK (NJAC 7:9A-8.2) 250 GAL. PER BEDROOM REQUIRED REQUIRED CAP. = 3(250) = 750 GAL. PROVIDE 1,000 GAL. SEPTIC TANK
AutoCAD SHX Text
GENERAL NOTES 1. EXISTING SPTIC SYSTEM TO BE PROPERLY ABANDONED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. CONTRACTOR TO NOTIFY ENGINEER OF ANY ALTERATIONS TO THIS DESIGN DUE TO THE EXISTING SEPTIC SYSTEM. 2. STABILIZE ALL SLOPES; SLOPES TO BE 3:1 MAX. STABILIZE ALL SLOPES; SLOPES TO BE 3:1 MAX. 3. ALL PIPES TO TANKS TO BE HDPE OR SCHEDULE 40 PVC SLOPED AT 0.02 FT PER ALL PIPES TO TANKS TO BE HDPE OR SCHEDULE 40 PVC SLOPED AT 0.02 FT PER FT MINIMUM. 4. DWELLING SERVICED BY PRIVATE WELL. DWELLING SERVICED BY PRIVATE WELL. 5. ALL TANKS AND DISTRIBUTION BOXES TO BE PRECAST CONCRETE AS PER ALL TANKS AND DISTRIBUTION BOXES TO BE PRECAST CONCRETE AS PER PEERLESS CONCRETE OR EQUAL. 6. NO WELLS WITHING 100' OF NEW SEPTIC AND NO CASED WELLS OR EXISTING NO WELLS WITHING 100' OF NEW SEPTIC AND NO CASED WELLS OR EXISTING SEPTICS WITHIN 50' OF NEW SEPTIC. 7. HEALTH DEPARTMENT AND DESIGN ENGINEER TO HAVE MINIMUM 1 WEEK NOTICE HEALTH DEPARTMENT AND DESIGN ENGINEER TO HAVE MINIMUM 1 WEEK NOTICE PRIOR TO STARTING CONSTRUCTION OF NEW SEPTIC 8. DESIGN ENGINEER TO PROVIDE AS-BUILT DRAWING OF COMPLETED SEPTIC SYSTEM DESIGN ENGINEER TO PROVIDE AS-BUILT DRAWING OF COMPLETED SEPTIC SYSTEM 9. ENGINEER NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS NOT ENCOUNTERED ENGINEER NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS NOT ENCOUNTERED DURING FIELD TESTS OR SHOWN ON SURVEY. 10. ALL SURROUNDING DWELLINGS ARE SERVICED BY PRIVATE WELL. ALL SURROUNDING DWELLINGS ARE SERVICED BY PRIVATE WELL. 11. THE ENGINEER'S LIABILITY WITH REGARD TO THIS SUBSURFACE SEWAGE DISPOSAL THE ENGINEER'S LIABILITY WITH REGARD TO THIS SUBSURFACE SEWAGE DISPOSAL SYSTEM TERMINATES UPON APPROVAL OF THE LOCAL AUTHORITY UNLESS THE ENGINEER IS CONTRACTED TO INSPECT AND SUPERVISE THE INSTALLATION OF THE SAME. THE ENGINEER IS TO BE NOTIFIED AT LEAST 48 HOURS PRIOR TO INSPECTIONS IF REQUIRED. THE ENGINEER IS ALSO TO BE NOTIFIED BY THE OWNER OR CONTRACTOR OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS AND OF ANY CHANGES. 12. SYSTEM TO BE STAKED OUT PRIOR TO CONSTRUCTION. SYSTEM TO BE STAKED OUT PRIOR TO CONSTRUCTION. 13. CONTRACTOR TO VERIFY INVERTS OF EXISTING PIPE OUTLETS FROM BOTH CONTRACTOR TO VERIFY INVERTS OF EXISTING PIPE OUTLETS FROM BOTH STRUCTURES TO ENSURE GRAVITY FLOW TO SEPTIC TANK 14. THERE ARE NO WETLANDS OR WETLAND TRANSITION AREAS WITHIN 150 FEET OF THERE ARE NO WETLANDS OR WETLAND TRANSITION AREAS WITHIN 150 FEET OF NEW SEPTIC 15. ALL SOIL DISTURBANCE WITHIN 300 FEET OF CATEGORY 1 WATER QUALIFIES AS A ALL SOIL DISTURBANCE WITHIN 300 FEET OF CATEGORY 1 WATER QUALIFIES AS A PERMIT BY RULE SINCE IT OCCURS IN A PREVIOUSLY DISTURBED AREA. 16. SEPTIC SYSTEM REPAIR QUALIFIES FOR NJAC 7:13A PERMIT BY RULE 4,10 AND 39 SEPTIC SYSTEM REPAIR QUALIFIES FOR NJAC 7:13A PERMIT BY RULE 4,10 AND 39 17. NO EJECTOR PUMPS ARE PROPOSED IN ANY BUILDING. NO EJECTOR PUMPS ARE PROPOSED IN ANY BUILDING. 18. PORTIONS OF THE EXISTING SEPTIC SYSTEM ENCOUNTERED SHALL BE PROPERLY PORTIONS OF THE EXISTING SEPTIC SYSTEM ENCOUNTERED SHALL BE PROPERLY DISPOSED AND THE SECTION BACKFILLED WITH COMPACTED SILTY CLAY SOILS. 19. CONTRACTOR TO BE PROPERLY LICENSED BY MT. OLIVE TOWNSHIP. CONTRACTOR TO BE PROPERLY LICENSED BY MT. OLIVE TOWNSHIP. 20. THE DESIGN ENGINEER MUST CERTIFY WATER TIGHTNESS OF ALL NEW TANKS. THE DESIGN ENGINEER MUST CERTIFY WATER TIGHTNESS OF ALL NEW TANKS. 21. REVIEW OF FEMA FLOOD INSURANCE RATE MAP PANEL 340353 0002 B EFFECTIVE REVIEW OF FEMA FLOOD INSURANCE RATE MAP PANEL 340353 0002 B EFFECTIVE DATE MAY 5, 1985 INDICATES NO FLOOD HAZARD ELEVATION DATA IS AVAILABLE FOR THIS LOT. 22. ALL ABANDONED SEPTIC TANKS, PUMP TANKS, DRY WELLS AND CESSPOOLS SHALL ALL ABANDONED SEPTIC TANKS, PUMP TANKS, DRY WELLS AND CESSPOOLS SHALL BE PUMPED OUT BY A LICENSED WASTE HAULER AND RECEIPTS PROVIDED AS PROOF OF PROPER DISPOSAL. TANKS, STRUCTURES, ETC. NOT REMOVED TO BE FILLED WITH GRANULAR MATERIAL OR CRUSHED AND THE AREAS FILLED WITH GRANULAR SOIL AND COMPACTED AS REQUIRED. 23. ENGINEER RECOMMENDS THAT WATER CONSERVATION DEVICES BE INSTALLED IN ENGINEER RECOMMENDS THAT WATER CONSERVATION DEVICES BE INSTALLED IN DWELLING. THE OWNER, BY LIMITING WATER USAGE, HAS THE ULTIMATE CONTROL OVER THE SATISFACTORY OPERATION OF THE SEPTIC SYSTEM. 24. FILL USED IN DISPOSAL FIELD SHALL BE LIGHTLY COMPACTED IN 1 FT. LIFTS IN FILL USED IN DISPOSAL FIELD SHALL BE LIGHTLY COMPACTED IN 1 FT. LIFTS IN ACCORDANCE WITH NJAC 7:9A 10.4 (f) 3. 25. THE ELECTRICAL AND PLUMBING WORK IS NOT INSPECTED BY THE ENGINEER. THE THE ELECTRICAL AND PLUMBING WORK IS NOT INSPECTED BY THE ENGINEER. THE OWNER OR CONTRACTOR TO OBTAIN THE PROPER PERMITS FROM THE BUILDING DEPT. 26. ANY TREES WITHIN 10' OF PROPOSED SEPTIC SHALL BE REMOVED. ANY TREES WITHIN 10' OF PROPOSED SEPTIC SHALL BE REMOVED. 27. AT LEAST 3 BUSINESS DAYS BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR AT LEAST 3 BUSINESS DAYS BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR SHALL CALL GARDEN STATE UNDERGROUND 1-800-272-1000 TO LOCATE EXISTING UTILITIES AND SHALL NOTIFY THE ENGINEER OF ANY POTENTIAL CONFLICTS FOUND. 31. CONTRACTOR TO OBTAIN ALL PERMITS PRIOR TO BEGINNING WORK. 32. ALL MATERIALS AND WORK TO CONFORM TO NJAC 7:9A AND LOCAL. HEALTH CODE. SELECT FILL FOR ZONE OF TREATMENT TO MEET NJAC 7:9A-10.1(f) 4. 33. NO WATER SOFTENERS, POOL BACKWASH OR GARBAGE GRINDERS TO BE DRAINED TO THE SEPTIC SYSTEM. 34. BACKFILLING FOR FINAL GRADING, SHALL BE SEEDED, OR OTHERWISE STABILIZED IN A MANNER ACCEPTABLE TO THE ADMINISTRATIVE AUTHORITY. 35. SYSTEM TO BE MAINTAINED IN ACCORDANCE WITH NJAC 7:9 A CHAPTER 12 AND AS NOTED ON THIS PLAN.
AutoCAD SHX Text
EXISTING GRADE 981.7
AutoCAD SHX Text
PROPOSED GRADE 982.1
AutoCAD SHX Text
LEVEL OF INFILTRATION
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
%%UTYPICAL DISPOSAL FIELD DETAIL (SRB)
AutoCAD SHX Text
EXISTING MATERIAL TO REMAIN
AutoCAD SHX Text
ZONE OF DISPOSAL EXISTING K3 MATERIAL
AutoCAD SHX Text
ZONE OF TREATMENT SUITABLE K4 FILL (18" FOR ALTERNATIVE SYSTEM)
AutoCAD SHX Text
33" K4 MATERIAL TOTAL (SEE NOTE 1)
AutoCAD SHX Text
4" MIN. -18" MAX. BACKFILL
AutoCAD SHX Text
BOTTOM OF ZONE OF TREATMENT 978.8
AutoCAD SHX Text
LATERAL INV. 980.3
AutoCAD SHX Text
SELECT FILL NOTES: 1. SUITABLE K4 FILL TO BE ASTM C-33 SAND IN SUITABLE K4 FILL TO BE ASTM C-33 SAND IN CONFORMANCE WITH NJAC 7:9A 10.1 f (4) 2. PERMEABILITY = 6-20 INCHES/HOURPERMEABILITY = 6-20 INCHES/HOUR
AutoCAD SHX Text
12" PRESBY AES PIPES (5 TOTAL)
AutoCAD SHX Text
EXISTING GRADE 982.1
AutoCAD SHX Text
PROPOSED GRADE 982.5
AutoCAD SHX Text
BOTTOM OF ZONE OF DISPOSAL 974.8
AutoCAD SHX Text
BOTTOM OF SOIL LOG 1 973.5 (8.0 FT.)
AutoCAD SHX Text
1'-3' TO EXISTING GRADE
AutoCAD SHX Text
LEVEL OF INF. 979.8
AutoCAD SHX Text
1.0' EDGE SPACING ALL AROUND
AutoCAD SHX Text
DB5138 PG152
AutoCAD SHX Text
%%uSIDE VIEW
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
NTS
AutoCAD SHX Text
OFFSET ADAPTER
AutoCAD SHX Text
ELBOW LEVEL WITH TOP OF OFFSET ADAPTER
AutoCAD SHX Text
RANDOMLY ORIENTED FIBER MAT
AutoCAD SHX Text
GEOTEXTILE FIBER WRAP
AutoCAD SHX Text
ADVANCED ENVIRO-SEPTIC PIPE
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
GEO-TEXTILE FABRIC
AutoCAD SHX Text
%%UPLAN VIEW
AutoCAD SHX Text
(NO SCALE)
AutoCAD SHX Text
RAISED ADAPTERS
AutoCAD SHX Text
INLET
AutoCAD SHX Text
TO VENT
AutoCAD SHX Text
RANDOMLY ORIENTED FIBER MAT
AutoCAD SHX Text
ROWS AS NEEDED
AutoCAD SHX Text
2"-4"
AutoCAD SHX Text
OFFSET ADAPTER
AutoCAD SHX Text
RANDOMLY ORIENTED FIBER MAT
AutoCAD SHX Text
GEOTEXTILE FIBER WRAP
AutoCAD SHX Text
ENVIRO-SEPTIC PIPE
AutoCAD SHX Text
4" LOW VENT ATTACHED TOEND OF LAST ROW
AutoCAD SHX Text
SCREEN OPENING
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SYSTEM SAND
AutoCAD SHX Text
CLEAN SAND FILL
AutoCAD SHX Text
LOAM AND SEED ALL FINAL GRADES. NO DEEP ROOTED PLANT MATERIALS ON SYSTEM OR OVERFILL AREAS.
AutoCAD SHX Text
2"-4"
AutoCAD SHX Text
TYPICAL LOW VENT CONNECTION FOR SERIAL DISTRIBUTION
AutoCAD SHX Text
%%USECTION VIEW
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
%%UTYPICAL 12" HDPE AES LATERAL PIPE
AutoCAD SHX Text
NOTES: 1. SYSTEM TO BE PRESBY ADVANCED ENVIRO SYSTEM TO BE PRESBY ADVANCED ENVIRO SEPTIC (AES) 2. REFER TO PRESBY DESIGN AND INSTALLATION REFER TO PRESBY DESIGN AND INSTALLATION SPECIFICATIONS FOR FULL SYSTEM DETAILS
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
RR
AutoCAD SHX Text
RR
AutoCAD SHX Text
RR
AutoCAD SHX Text
10.18.21
AutoCAD SHX Text
as shown
AutoCAD SHX Text
chaim
AutoCAD SHX Text
SEPTIC SYSTEM ALTERATION PLAN
AutoCAD SHX Text
CHAIM RESIDENCE
AutoCAD SHX Text
24 CAMP PULASKI ROAD
AutoCAD SHX Text
BLOCK 400 LOT 5
AutoCAD SHX Text
MT. OLIVE TWP., MORRIS COUNTY, NJ
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
CHECK BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
OR TO WHOM IT IS CERTIFIED.
AutoCAD SHX Text
THIS DRAWING AND ALL INFORMATION CONTAINED
AutoCAD SHX Text
HEREIN IS AUTHORIZED FOR USE ONLY BY THE
AutoCAD SHX Text
PARTY FOR WHOM THE WORK WAS CONTRACTED
AutoCAD SHX Text
THIS DRAWING MAY NOT BE COPIED, REUSED,
AutoCAD SHX Text
DISCLOSED, DISTRIBUTED OR RELIED UPON FOR
AutoCAD SHX Text
ANY OTHER PURPOSE WITHOUT THE WRITTEN
AutoCAD SHX Text
CONSENT OF ROBERT ROSELLI, PE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
N.J. LIC. NO. 42542
AutoCAD SHX Text
ROBERT ROSELLI, P.E.
AutoCAD SHX Text
ROBERT ROSELLI, PE
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
TEL: (201) 993-0781 email: [email protected]
AutoCAD SHX Text
213 ROUTE 100, KATONAH, NY 10536
AutoCAD SHX Text
PO BOX 837, MAHWAH, NJ 07430
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
EXISTING CONTOUR
AutoCAD SHX Text
EXISTING SPOT ELEVATION
AutoCAD SHX Text
T/W
AutoCAD SHX Text
B/W
AutoCAD SHX Text
BOTTOM OF WALL
AutoCAD SHX Text
TOP OF WALL
AutoCAD SHX Text
PROPOSED CONTOUR
AutoCAD SHX Text
PROPOSED SPOT ELEVATION
AutoCAD SHX Text
100.0
AutoCAD SHX Text
X 87.65
AutoCAD SHX Text
%%USEPTIC SITE PLAN
AutoCAD SHX Text
%%ULOCATION PLAN
AutoCAD SHX Text
%%USOILS MAP
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text
SURVEY NOTES 1. BOUNDARY AND TOPOGRAPHIC SURVEY BY PAX BOUNDARY AND TOPOGRAPHIC SURVEY BY PAX SURVEYING, WILLIAM J. MANNING, PLS FOR BLOCK 400 LOT 5 24 CAMP PULASKI ROAD, MT. OLVE DATED MARCH 20, 2019. 2. DATUM NAVD 88. DATUM NAVD 88. 3. ALL KNOWN EASEMENTS ARE SHOWN.ALL KNOWN EASEMENTS ARE SHOWN.
AutoCAD SHX Text
SOIL LOG
AutoCAD SHX Text
100
AutoCAD SHX Text
1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
0
AutoCAD SHX Text
30
AutoCAD SHX Text
30
AutoCAD SHX Text
60
AutoCAD SHX Text
30
AutoCAD SHX Text
120
AutoCAD SHX Text
15
AutoCAD SHX Text
100
AutoCAD SHX Text
X
AutoCAD SHX Text
T-1