Binder4 · REPENTANCE SERIES LUI THE SPIRITUAL WAKE H. H. Pope shenouda 111 12tn Print June 2003
Binder4
-
Upload
sorel-enegy -
Category
Documents
-
view
215 -
download
1
description
Transcript of Binder4
Concept:
Construct a multi-purpose space: 1. temporary housing during home construction of main house 2. accomodations for office and guest quarters 3. car storage and open pavilion for outdoor activities
Design Criteria:
1. create a space that maximizes use through out building life cycle. 2. serve as a transitional element tieing the project to the neighborhood vernacular 3. use innovative building technologies and building systems to minimize impact on environment and increase building energy efficiency
The Ford Y studio
A3.1THIS DOCUMENT AND THE DESIGN IDEAS INCORPORATED HEREIN ARE AN INSTRUMENT OF PROFESSIONAL SERVICE AND SOLE PROPERTY OF KELLER ARCHITECTURE AND IS NOT TO BE USED, IN WHOLE OR PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF KELLER ARCHITECTURE.
86081
ITECT
SA
AREDR
EGIS
R
TE
T EO FTATS
E X
CH
RE
LLEKR.LE
HCIM
A
hous
ton,
Tex
as
copyrighted documentc
ford
Y h
ouse
tula
ne
Project:08006
Document Issue history:
04.04.2007 Client Review 109.17.2007 Client Review 210.01.2007 Client Review 311.12.2007 Snapshot Set12.18.2007 Client Review 4
ISSU
ED FO
R RE
VIEW
8TH
JULY
2008
12.31.2007 Client Review 501.25.2008 Client Review 602.04.2008 Pricing02.13.2008 Issue for Permit
Front Elevation1Back Elevation2
West Elevation3East Elevation4
First Floor+6"
Second Floor+11'-7 1/8"
Attic Storage+19'-7 1/8"
roof+27'-7 1/8"
8'-0
"1'
-0"
6'-1
0"
13'-5"
15'-3 1/2"
13'-4"
8'-9
"
30 YR. COMPOSITIONSHINGLE WITH 15#FELT PAPERAND 1/2" TECHSHIELD SHEATHING
RIDGE VENT TYPICAL
11
18
08
05
5
85 1
/22
7 1
/2
17'-7
"
6" HARDI SIDING 3 COAT TRUESTUCCO NATURALFINISH
First Floor+6"
Second Floor+11'-7 1/8"
Attic Storage+19'-7 1/8"
roof+27'-7 1/8"
3:12 PITCH 10:12 PITCH3:12 PITCH10:12 PITCH
SIP Panel Construction
Heat ExchangerReclaimed Shiplap Siding
Isonyne Foam InsulationRadiant Barrier
A3.1THIS DOCUMENT AND THE DESIGN IDEAS INCORPORATED HEREIN ARE AN INSTRUMENT OF PROFESSIONAL SERVICE AND SOLE PROPERTY OF KELLER ARCHITECTURE AND IS NOT TO BE USED, IN WHOLE OR PART FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF KELLER ARCHITECTURE.
86081
ITECT
SA
AREDR
EGIS
R
TE
T EO FTATS
E X
CH
RE
LLEKR.LE
HCIM
A
hous
ton,
Tex
as
copyrighted documentc
ford
Y h
ouse
tula
ne
Project:08006
Document Issue history:
04.04.2007 Client Review 109.17.2007 Client Review 210.01.2007 Client Review 311.12.2007 Snapshot Set12.18.2007 Client Review 4
ISSU
ED FO
R RE
VIEW
8TH
JULY
2008
12.31.2007 Client Review 501.25.2008 Client Review 602.04.2008 Pricing02.13.2008 Issue for Permit
Front Elevation1Back Elevation2
West Elevation3East Elevation4
First Floor+6"
Second Floor+11'-7 1/8"
Attic Storage+19'-7 1/8"
roof+27'-7 1/8"
8'-0
"1'
-0"
6'-1
0"
13'-5"
15'-3 1/2"
13'-4"
8'-9
"
30 YR. COMPOSITIONSHINGLE WITH 15#FELT PAPERAND 1/2" TECHSHIELD SHEATHING
RIDGE VENT TYPICAL
11
18
08
05
5
85 1
/22
7 1
/2
17'-7
"
6" HARDI SIDING 3 COAT TRUESTUCCO NATURALFINISH
First Floor+6"
Second Floor+11'-7 1/8"
Attic Storage+19'-7 1/8"
roof+27'-7 1/8"
3:12 PITCH 10:12 PITCH3:12 PITCH10:12 PITCH
leed Project
3911 Main S treet Hous ton, Texas 77002
the Ford Y house brought to you by Shade House Developmentpushing the green envelope with SIP panel construction, solar panels.
Energy Effficiency:
Insulated structural panels Tankless water heater Solar panels tied to grid Radiant Barrier House Wrap Passive Solar Design site placement High Efficiency HVAC system Reflective roofinig for minimizing heat gain expanding foam insulation
Healthy Home Environment: No VOC paint for interiors ERV (energy recovery ventilator) Fresh Air Supply No VOC wood floor finish American Clay wall and ceiling finish Air filtration System
Water Management: minimal footprint of pervious area Low Flow sink and shower indigenous landscape requiring no irrigation Rainwater harvesting
mrk.jump.04.2009:09022_PRJ_02.pln
The Men's CenterA New Facility Design15 Rooms per floor with 2 Beds each = 30 Beds 4 Floors with 30 Beds = 120 Beds
2 1345
2 1345
A
B
C
D
mrk.jump.04.2009:09022_PRJ_02.pln
12345678910
10 parking places12345678910
10 parking places
1234567891011121314
14 parking places11111
12345678910
10 parking places12345678910
10 parking places
SCALE: 3/32" = 1'-0"
A5 Site Plan @ 1st Floor 0 8' 16' 24'
15 Rooms per floorBathroom and Laundry on each Floor
2 1345
2 1345
A
B
C
D
mrk.jump.04.2009:09022_PRJ_02.pln
1 2 3 4 5 6 7 8
9101112131415161718192021
12345678
9101112131415161718192021
1 2 3 4 5 6 7 8
9101112131415161718192021
12345678
9101112131415161718192021
1 2 3 4 5 6 7 8
9101112131415161718192021
12345678
9101112131415161718192021
1 2 3 4 5 6 7 8
9101112131415161718192021
12345678
9101112131415161718192021
SCALE: 3/16" = 1'-0"
A5 2nd Floor Finish Plan 0 4' 8' 12'
SCALE: 3/16" = 1'-0"
C5 3rd & 4th Floor Plans 0 4' 8' 12'
A1.10
CONSULTANTS
SHEET TITLE 05/10/09
Architect:Date:
Michael R. Keller05/10/09
Not for regulatory approval,permitting, or construction
A
B
2 1
C
D
345
2 1345
A
B
C
D
SHEET ___ OF ___
Document InformationCAD FILE NAME: 1003_prj01.pln
DESIGNED BY: Michael Keller DRAWN BY: Gene Johnston CHECKED BY: Michael Keller COPYRIGHT: Keller Architecture - 2010
Legal NotesTHE SEAL APPEARING ON THIS DOCUMENT WASAUTHORIZED BY MICHAEL R. KELLER, AIA, TEXAS #18068.THE ORIGINAL SIGNED DOCUMENT IS HELD AT THE OFFICEOF; KELLER ARCHITECTURE.
#Project Name10 Waverly Court, Texas 77004
Job Number: 1003Client: The Brown's Residence
314
MESSINA:1003_prj01.pln
Architectural Site Plan
Conceptual
101 Crawford Suite 110B voice: 713.527.0527Houston , Texas 77002 fax: [email protected] kellerdesign.blogspot.com
Project HistoryDate: Issue: 00.00.00 Client Review (SD)00.00.00 Design Review (DD)00.00.00 Client Review (CD)00.00.00 Client Review (CD)
Monday, April 12, 20104:26 PM
10'-0"1
2'-4"
6'-0"
SOLYNDRA 182W MODULE IN
CUSTOM ARMATURE FOR
VERTICAL INSTALLATION
HORIZONTAL CEDAR OR
COMPOSITE SIDING
BATTERY STORAGE TO BE
LOCATED IN MAINTENANCE
AREA
EX
IST
FE
NC
E
PO
LE
S
FE
NC
E
Fence Elevation
Initial Concept
UP