BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system...

77
BILL OF QUANTITY

Transcript of BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system...

Page 1: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

BILL OF QUANTITY

Page 2: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

Schedule Item DSR - 2013 Non-Schedule Item

A CIVIL WORKS

B PLUMBING WORKS

C FIRE FIGHTING WORKS

D ELECTRICAL, FIRE ALARM SYSTEM & LIFTS

 In Words

SIGNATURE OF AUTHORIZED SIGNATORY OF TENDERER

NAME OF SIGNATORY

NAME AND SEAL OF TENDERER

TOTAL OF ALL SCHEDULES (A) TO (D) AFTER APPLYING REBATE (RUPEES) (In Figures)

TOTAL OF ALL SCHEDULES (A) TO (D)

UNCONDITIONAL REBATE

Amount

Package-I (Academic , Admin, Lecture hall, Library, Work Shop, ESS, & Check Dam) Construction Of National Institute Of Technology Meghalya at Sohra

S. No. Name of Work

GRAND SUMMARY

Page 3: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

Schedule Item DSR - 2013 Non-Schedule Item

A CIVIL WORKS1 EARTH WORK2 CONCRETE WORK3 RCC WORK4 BRICK WORK5 STONE WORK6 MARBLE WORK7 WOOD WORK8 STEEL WORK9 FLOORING WORK10 ROOFING WORK11 FINISHING WORK12 ALUMINIUM WORK13 WATER PROOFING WORK14 ROAD WORK

SUB TOTAL (A)

B PLUMBING WORKS1 SANITARY FIXTURES2 INTERNAL DRAINAGE3 INTERNAL WATER SUPPLY4 MISCELLANEOUS ITEMS.

SUB TOTAL (B)

C FIRE FIGHTING WORKS1 PIPING, HYDRANT and ACCESSORIES SYSTEM

SUB TOTAL (C)D=Grand Total (A+B+C)

Construction Of National Institute Of Technology Meghalaya at SohraPackage-I (Academic , Admin, Lecture hall, Library, Work Shop, ESS, & Check Dam)

SUMMARY OF COST

S. No. Name of Work Amount

Page 4: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

Schedule Item DSR - 2013 Non-Schedule Item

Construction Of National Institute Of Technology Meghalaya at SohraPackage-I (Academic , Admin, Lecture hall, Library, Work Shop, ESS, & Check Dam)

SUMMARY OF COST

S. No. Name of Work Amount

E ELECTRICAL, FIRE ALARM SYSTEM & LIFTS1 ELECTRICAL PANELS2 LT CABLE & TERMINATION3 CABLE TRAY4 DISTRIBUTION BOARD5 SUBMAIN6 POINT WIRING7 LIGHT FIXTURES8 LIGHTNING PROTECTION 9 EARTHING

10 POWER BACKUP & LIGHTING CONTROL SYSTEM11 FIRE ALARM12 PUBLIC ADDRESS SYSTEM13 CCTV SYSTEM14 SAFETY EQUIPMENTS15 DEHUMIDIFICATION16 LIFTS

SUB TOTAL (E)Grand Total (D+E)

Page 5: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

EARTH WORKI. Schedule Item

1 2.6 Earth work in excavation by mechanical means (Hydraulicexcavator )/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sum on plan) including disposal ofexcavated earth, lead upto 50m and lift upto 1.5m, disposed earthto be levelled and neatly dressed.

2.6.1 All kinds of soil cum 2373.00

2 2.7 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means over areas (exceeding 30 cm in depth,1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50 m and lift upto 1.5 m, disposed earthto be levelled and neatly dressed.

2.7.1 Ordinary rock cum 412.842.7.3 Hard rock (blasting prohibited) cum 412.84

3 2.8 Earth work in excavation by mechanical means (Hydraulicexcavator) / manual means in foundation trenches or drains (notexceeding 1.5 m in width or 10 sqm on plan) including dressing ofsides and ramming of bottoms, lift upto 1.5 m, including getting outthe excavated soil and disposal of surplus excavated soil asdirected within a lead of 50 m

2.8.1 All kinds of soil. cum 5577.00

4 2.9 Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains not exceeding 1.5m in width or 10 sqm on plan including getting out the excavatedsoil and disposal of surplus excavated soils as directed, dressing ofsides and ramming of bottoms, lift upto 1.5 m, including within alead of 50m

2.9.1 Ordinary rock cum 1135.002.9.3 Hard rock (blasting prohibited) cum 1222.00

5 2.10 Excavating trenches of required width for pipes, cables, etcincluding excavation for sockets, and dressing of sides, ramming ofbottoms, depth upto 1.5 m including getting out the excavated soil,and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer byramming, watering, etc. and disposing of surplus excavated soil asdirected within a lead of 50 m :

2.10.1 All kinds of soil

Quoted Rate

CIVIL WORK

Amount

Construction Of National Institute Of Technology Meghalaya at SohraBill Of Quantity for Package‐I (Academic , Admin, Lecture hall, Library, Work Shop, ESS, & Check Dam) 

Scheduled Items

S.No. DSR 2013 Description of Items Unit Quantity

Page 6: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mmdia. metre 1160.00

6 2.11 Extra for excavating trenches for pipes, cables etc. in all kinds ofsoil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is overcorresponding basic item for depth upto 1.5 metre). metre 1160.00

7 2.12 Extra for excavating trenches for pipes, cables, etc, in all kinds ofsoil for depth exceeding 3 m in depth, but not exceeding 4.5 m.(Rate is over corresponding basic item for depth upto 1.5 metre.)

metre 150.00

8 2.13 Excavating trenches of required width for pipes, cables, etc,including excavation for sockets, depth upto 1.5 m including gettingout the excavated materials, returning the soil as required in layersnot exceeding 20 cm in depth, including consolidating eachdeposited layers by ramming, watering etc., stacking serviceablematerial for measurements and disposal of unserviceable materialas directed within a lead of 50m :

2.13.1 Ordinary rock :2.13.1.2 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm

dia. metre 100.009 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary

exceeding 1.5 m in depth but not exceeding 3 m. (Rate is overcorresponding basic item for depth upto 1.5 metre.) (for checkDam) metre 100.00

2.13.3 Hard rock (blasting prohibited)2.13.3.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300

mm dia. metre 390.00

10 2.14 Extra for excavating trenches for pipes, cables, etc. in ordinary/hardrock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is overcorresponding basic item for depth upto 1.5 metre.)

metre 390.00

11 2.15 Extra for excavating trenches for pipes, cables, etc. in ordinary/hardrock exceeding 3m in depth but not exceeding 4.5 m. (Rate is overcorresponding basic item for depth upto 1.5 metre.)

metre 100.00

12 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m. cum 12488.00

13 2.26 Extra for every additional lift of 1.5 m or part thereof in2.26.1 All Kind Of Soil Cum 153.002.26.2 Ordinary or hard rock cum 341.00

Page 7: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

14 2.27 Supplying and filling in plinth with Local sand under floors including,watering, ramming consolidating and dressing complete.

cum 2094.00

15 2.34 Supplying chemical emulsion in sealed containers includingdelivery as specified.

2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 5006.00

16 16.3 Supplying and stacking at site. 16.3.9 Good earth. cum 2726.00

17 2.37 Supply and stacking of Fly ash conforming to IRC- 58 at site,including carriage, loading , unloading & stacking up to any lead(measured stacks will be reduced by 20% for payment) cum 2642.00

18 2.38 Filling with available fly ash and earth (excluding rock) in trenchesor embankment in layers (each layer should not exceed 15 cm),with intermediate layer of compacted earth (Soil density of 98%)after every four layers of compacted depth of fly ash, sides & toplayer of filling shall be done with earth having total minimumcompacted thickness 30 cm or as decided by Engineer -in-charge,including compacting each layer by rolling/ ramming and watering,all complete as per drawing and direction of Engineer -in - charge

cum 3882.00

19 1.1 Carriage of Material by mechanical Transport Including loadingunloading and Sacking within 5km.

1.1.2 Excavated Earth Cum 3448.001.1.3 Excavated Rock Cum 2795.681.1.3 Excavated Rocks 2 KM Cum 250.00

Total of Schedule Item Earth work (I) :

CONCRETE WORKI. Schedule Item

20 4.1 Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel :

4.1.8 1:4:8 (1 cement : 4 Coarse sand : 8 graded stone aggregate 40 mmnominal size) cum 2188.00

21 4.2 Providing and laying cement concrete in retaining walls, returnwalls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts, struts, buttresses, string or lacingcourses, parapets, coping, bed blocks, anchor blocks, plain windowsills, fillets, sunken floor,etc., up to floor five level,excluding the costof centering, shuttering and finishing :

Page 8: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

4.2.2 1:11/2:3 (1 cement:11/2 coarse sand:3 graded stone aggregate 20mm nominal size).

cum 20.004.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20mm

nominal size) cum 20.21

22 4.6 Providing and fixing at or near ground level precast cementconcrete in kerbs, edgings etc. as per approved pattern and settingin position with cement mortar 1:3 (1 Cement : 3 coarse sand),including the cost of required centering, shuttering complete.

4.6.1 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) cum 78.00

23 4.10 Providing and laying damp-proof course 40mm thick with cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5mm nominal size). sqm 1268.00

24 4.12 Extra for providing and mixing water proofing material in cementconcrete work @ 1 kg per 50kg of cement. Kg 325.00

25 4.13 Applying a coat of residual petroleum bitumen of penetration 80/100of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. sqm 2728.00

26 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed by dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth. sqm 2348.00

27 4.8 Providing and fixing up to floor five level precast cement concretehollow block including hoisting and setting in position with cementmortar 1:3 (1 cement : 3 coarse sand), cost of required centering,shuttering complete.

4.8.1 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mmnominal size).

cum 7029.00

Total of Schedule Item Earth work (I) :

R C C WORK

I. Schedule Item28 5.9 Centring and shuttering including strutting, propping etc. and

removal of form for :a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.

sqm 5851.00b 5.9.2 Walls (any thickness) including attached pilasters, butteresses,

plinth and string courses etc. sqm 1206.00

Page 9: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

c 5.9.3 Suspended floors, roofs, landings, balconies and access platform.sqm 33487.00

d 5.9.4 Shelves Sqm 123.00e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.

sqm 37183.00f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 19650.00g 5.9.7 Stairs, (excluding landings) except spiral-staircases. sqm 749.00h 5.9.14 Extra for shuttering in circular work (20% of respective centring and

shuttering itema Foundations, footings, bases of columns, etc. for mass concrete.

sqm 975.00b Lintels, beams, plinth beams, girders, bressumers and cantilevers.

sqm 6001.00i 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in

cornices, window sills, string courses, bands, copings, bed plates,anchor blocks and the like sqm 333.00

j 5.9.16 Edges of slabs and breaks in floors and walls5.9.16.1 Under 20 cm wide metre 5366.00

k 5.9.19 Weather shade, Chajjas, corbels etc., including edges sqm 931.00

29 5.11 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels,over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)

5.11.1 Suspended floors, roofs, landing, beams and balconies (Planarea to be measured).

sqm 32636.00

29 5.16 Providing, hoisting and fixing up to floor five level precast reinforcedcement concrete in shelves, including setting in cement mortar 1:3(1 cement : 3 coarse sand), cost of required centering, shutteringand finishing with neat cement punning on exposed surfaces butexcluding the cost of reinforcement, with 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 12.5 mm nominal size).

cum 43.00

30 5.18 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarsesand: 4 graded stone aggregate 6 mm nominal size), reinforcedwith 1.6 mm dia mild steel wire, including centering and shuttering,roughening cleaning, fixing and finishing in cement mortar 1:3 (1cement: 3 fine sand) etc. complete, excluding plastering of thejambs sills and soffits

5.18.1 50 mm thick sqm 3999.00

31 5.22 Steel Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete.UptoPlinth

5.22.6 Thermo-Mechanically Treated bars. kg 555044.70

Page 10: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

5.22 A Steel Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete.AbovePlinth

5.22A.6 Thermo-Mechanically Treated bars. kg 2877419.00

32 5.29 Providing and fixing sheet covering over expansion joints with ironscrews as per design to match the colour / shade of walltreatment.

5.29.2 Aluminium fluted strips 3.15mm thick.5.29.2.2 200 mm wide. metre 72.00

33 5.30 Add for plaster drip course/ groove in plastered surface or mouldingto R.C.C. projections. metre 3189.00

34 5.33 Providing and laying in position machine batched, machine mixedand machine vibrated design mix cement concrete of specifiedgrade for reinforced cement concrete work including pumping ofconcrete to site of laying but excluding the cost of centring,shuttering, finishing and reinforcement. including Admixtures inrecommended proportions as per IS 9103 to accelerate, retardsetting of concrete, improve workability without impairing strengthand durability as per direction of Engineer-in-charge. M-25 gradereinforced cement concrete by using 330 kg. of cement per cum ofconcrete.�

5.33.1 All work upto Plinth level. cum 3152.455.33.2 All work From Plinth Level & upto floor V level. cum 14694.10

35 5.34 Extra for providing richer mixes at all floor levels.Note:- Excess/less cement over the specified cement content usedis payable /recoverable separately.

5.34.1 Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note:- Cement content considered in M-30 is @ 340 kg/cum).

cum 2032.445.34.2 Providing M-35 grade concrete instead of M-25 grade BMC/RMC.

(Note : Cement content considered in M-35 is @ 350 kg/cum).

cum 3276.98

36 5.35 Add for using extra cement in the items of design mix over andabovethe specified cement content therein. quintal 15760.00

Total of Schedule Item RCC Work (I) :

BRICK WORKI. Schedule Item

37 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 in foundation and plinth in:

6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 540.00

Page 11: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 138.00

38 6.38 Providing and laying autoclaved aerated cement blocks masonrywith 100mm thick AAC blocks in super structure above plinth levelup to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand )The rate includes providing and placing in position 2 Nos. 6 mm diaM.S. bars at every third course of masonry work.

cum 2529.00

Total of Schedule Item Brick Work (I) :

STONE WORK7.1 Random rubble masonry with hard stone in foundation and plinth

including levelling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20mm nominal size) uptoplinth level with :

7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand). cum 618.00

7.2 Random rubble masonry with hard stone in superstructure aboveplinth level and upto floor five level, including leveling up withcement concrete 1:6:12 (1 cement : 6 coarse sand : 12 gradedstone aggregate 20mm nominal size) at window sills, ceiling leveland the like.

7.2.1 Cement mortar 1:6 (1 cement : 6 coarse sand). cum 2472.00

Total of Schedule ItemStone Work (I) :

MARBLE WORKI. Schedule Item

39 8.2 Providing and fixing 18mm thick gang saw cut mirror polished(premoulded and prepolished) machine cut for kitchen platforms,vanity counters ,window sills , facias and similar locations ofrequired size of approved shade, colour and texture laid over 20mmthick base cement mortar 1:4 (1 cement : 4 coarse sand) with jointstreated with white cement, mixed with matching pigment, epoxytouch ups, including rubbing, curing moulding and polishing to edgeto give high gloss finish etc. complete at all levels.

8.2.2 Granite of any colour and shade8.2.2.2 Area of slab over 0.50 sum. sqm 414.00

40 8.3 Extra for providing edge moulding to 18mm thick marble stonecounters, Vanities etc. including machine polishing to edge to givehigh gloss finish etc. complete as per design approved by Engineer-in-Charge.

8.3.2 Granite work. metre 807.00

Page 12: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

41 8.4 Extra for fixing marble /granite stone over and above correspondingbasic item, in facia and drops of width upto 150 mm with epoxyresin based adhesive including cleaning etc. complete.

metre 807.00

42 8.5 Extra for providing opening of required size & shape for washbasins/ kitchen sink in kitchen platform, vanity counters and similarlocation in marble/Granite/stone work including necessary holesfor pillar taps etc. including rubbing and polishing of cut edges etc.complete. each 184.00

43 8.8 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brickmasonry surface backing including drilling necessary holes and thecost etc complete.

8.8.1.2 Fastener with threaded dia 10 mm. each 15733.00

Total of Schedule Item Marble Work (I) :

WOOD WORKI. Schedule Item

44 9.21 Providing and fixing ISI marked flush door shutters conforming toIS: 2202 (Part I) non-decorative type, core of block boardconstruction with frame of 1st class hard wood and well matchedcommercial 3 ply veneering with vertical grains or cross bands andface veneers on both faces of shutters :

9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges withnecessary screws. sqm 1183.00

45 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mmminimum depth on all edges of shutters (over all area of doorshutter to be measured) Over item no. 9.20 and 9.21. sqm 1183.00

46 9.24 Extra for providing vision panel not exceeding 0.1 sum in all type offlush doors (cost of glass excluded) (overall area of door shutter tobe measured) :

9.24.1 Rectangular or square. sqm 966.00

47 9.26 Extra for cutting rebate in flush door shutters (Total area of theshutter to be measured). sqm 466.00

48 9.84 Providing and fixing IS : 3564 marked aluminium extruded sectionbody tubular type universal hydraulic door closer with double speedadjustment with necessary accessories and screws etc. complete.

each 1072.00

49 9.88 Providing and fixing chromium plated brass 100 mm mortice latchand lock with 6 levers and a pair of lever handles with necessaryscrews etc. complete (best make of approved quality).

each 827.00

Page 13: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

50 9.96 Providing and fixing aluminium sliding door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts andscrews etc. complete :

9.96.1 300x16 mm each 39.009.96.2 250x16 mm each 167.00

51 9.97 Providing and fixing aluminium tower bolts ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868 )transparent or dyed to required colour or shade with necessaryscrews etc. complete :

9.97.1 300x10 mm each 1188.009.97.3 200x10 mm each 1126.009.97.5 100x10 mm each 4377.00

52 9.100 Providing and fixing aluminium handles ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour or shade with necessaryscrews etc. complete :

9.100.1 125 mm each 2292.009.100.2 100 mm each 5704.009.100.3 75 mm each 174.00

53 9.101 Providing and fixing aluminium hanging floor door stopper ISImarked anodised (anodic coating not less than grade AC 10 as perIS : 1868) transparent or dyed to required colour and shade withnecessary screws etc. complete.

9.101.2 Twin rubber stopper each 1144.00

54 9.127 Providing & Fixing decorative high pressure laminated sheet ofplain / wood grain in gloss / matt / suede finish with high densityprotective surface layer and reverse side of adhesive bondingquality conforming to IS : 2046 Type S including cost of adhesive ofapproved quality.

9.127.2 1.0 mm thick. sqm 2300.00

Total of Schedule Item Wood & PVC Work (I) :

S T E E L WORK

55 10.3 Providing and fixing in position collapsible steel shutters withvertical channels 20x10x2mm and braced with flat iron diagonals20x5mm size, with top and bottom rail of T-iron 40x40x6mm, with40mm dia steel pulleys, complete with bolts, nuts, lockingarrangement, stoppers, handles, including applying a priming coatof approved steel primer.

sqm 142.00

I. Schedule Item

Page 14: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

56 10.6 Supplying and fixing rolling shutters of approved make, made ofrequired size M.S. laths interlocked together through their entirelength and jointed together at the end by end locks mounted onspecially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pulloperation complete including the cost of providing and fixingnecessary 27.5cm long wire springs grade No.2 and M.S. top coverof required thickness for rolling shutters

10.6.1 80x1.25mm M.S. laths with 1.25 mm thick top cover. sqm 236.00

57 10.7 Providing and fixing ball bearing for rolling shutters. each 82.00

58 10.16 Steel work in built up tubular ( round, square or rectangular hollowtubes etc.) trusses etc. including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer, includingwelding and bolted with special shaped washers etc. complete.

10.16.3 Electric resistance or induction butt welded tubes. kg 1245863.40

59 10.19 Providing and fixing mild steel round holding down bolts with nutsand washer plates complete.

kg 244423.20

60 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet boxfor ceiling fan clamp of internal dia 140mm, 73mm height, top lid of1.5mm thick M.S. sheet with its top surface hacked for properbonding, top lid shall be screwed into the cast iron/ M.S. sheet boxby means of 3.3mm dia. round headed screws, one lock at thecorners. Clamp shall be made of 12mm dia M.S. bar bent to shapeas per standard drawing each 2137.00

61 10.25 Steel work welded in built up sections/ framed work includingcutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer using structural steel etc. as required.

10.25.1 In stringers, treads, landings etc. of stair cases includinguse of chequered plate wherever required, all complete

kg 2000.0010.25.2 In gratings, frames, guard bar, ladder, railings, brackets,

gates and similar works.kg 2000.00

Page 15: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

62 10.28 Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) andfitting the same with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessary accessories &stainless steel dash fasteners , stainless steel bolts etc., of requiredsize, on the top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, ( for paymentpurpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.). kg 10023.00

63 D-10.28 Providing and fixing stainless steel ( Grade 304) railing made ofHollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (wherever required) andfitting the same with necessary stainless steel nuts and boltscomplete, i/c fixing the railing with necessary accessories &stainless steel dash fasteners , stainless steel bolts etc., of requiredsize, on the top of the floor or the side of waist slab with suitablearrangement as per approval of Engineer-in-charge, ( for paymentpurpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) kg 2496.00

Total of Schedule Item Steel work (I) :

FLOORING WORKI. Schedule Item

64 11.5 62 mm thick cement concrete flooring with concrete hardenertopping, under layer 50 mm thick cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) andtop layer 12mm thick cement hardener consisting of mix 1:2 (1cement hardener mix : 2 graded stone aggregate, 6mm nominalsize) by volume, hardening compound mixed @ 2 litre per 50kg ofcement or as per manufactures specifications. This includes cost ofcement slurry, but excluding the cost of nosing of steps etc.complete.

sqm 5126.00

65 11.6 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3(1 cement : 3 coarse sand) finished with a floating coat of neatcement.

11.6.1 18 mm thick. sqm 163.00

66 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath& courtyard, jointed with neat cement slurry mixed with pigment tomatch the shade of tiles, including rubbing and cleaning etc.complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4coarse sand).

11.20.1 Light shade using white cement. sqm 278.00

Page 16: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

67 11.23 Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbing andpolishing complete with :

11.23.3 Agaria White sqm 105.00

68 11.26 Kota stone slab flooring over 20 mm (average) thick base laid overand jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete withbase of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

11.26.1 25 mm thick. sqm 980.00

69 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed withpigment to match the shade of the slabs, including rubbing andpolishing complete. sqm 248.00

70 11.36 Providing and fixing Ist quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacturer ) ofapproved make in all colours, shades except burgundy, bottlegreen, black of any size as approved by Engineer-in-Charge inskirting, risers of steps and dados over 12 mm thick bed of cementMortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cementslurry @ 3.3kg per sum including pointing in white cement mixedwith pigment of matching shade complete.

sqm 5266.00

71 11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm(thickness to be specified by the manufacturer) of 1st qualityconforming to IS : 15622 of approved make in colours such asWhite, Ivory, Grey, Fume Red Brown, laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including pointing the jointswith white cement and matching pigment etc., complete.

sqm 1694.00

72 11.41 Providing and laying vitrified floor tiles in different sizes (thicknessto be specified by the manufacturer) with water absorption's lessthan 0.08% and conforming to IS : 15622 of approved make in allcolours and shades, laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with whitecement and matching pigments etc., complete.

11.41.2 Size of Tile 60x60 cm sqm 18357.00

Page 17: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

73 11.46 Providing and laying vitrified floor tiles in different sizes (thicknessto be specified by the manufacturer) with water absorption's lessthan 0.08% and conforming to IS : 15622 of approved make in allcolours and shades, in skirting, riser of steps, over 12 mm thick bedof cement mortar 1:3 (1 cement : 3 coarse sand) including groutingthe joints with white cement and matching pigments etc., complete.

11.46.2 Size of Tile 60x60 cm sqm 1494.00

74 11.34 38 mm thick wood block flooring of first class teak wood laid over25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 10 mm nominal size) to bepaid separately, coated with a thin layer of hot bitumen penetration80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks inposition after dipping in hot bitumen (blown type) up to half depth,planed, levelled smooth and finished complete.

sqm 334.00

75 16.64 Providing and laying 75mm thick compacted bed of dry brickaggregate of 40mm thick nominal size including spreading, wellramming, consolidating and grouting with jamuna sand includingfinishing smooth etc. complete as per direction of Engineer-in-charge. sqm 6600.00

76 16.68 Providing and laying 60mm thick factory made cement concreteinterlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including50mm thick compacted bed of fine sand, filling the joints with finesand etc. all complete as per the direction of Engineer-in-charge.

sqm 6750.00

Total of Schedule Item Flooring work (I) :

ROOFING WORKI. Schedule Item

77 12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as perstandard design :

12.21.1 In 75x75mm deep chase sqm 232.00

78 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cmcement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over P.V.C. sheet1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement : 3 coarse sand) and a coat of neat cement rounding theedge sand making and finishing the outlet complete.

sqm 19.00

Page 18: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

79 12.34 Providing and fixing thermal insulation of ceiling (under deckinsulation) with Resin Bonded Fibre glass wool conforming to IS :8183 density 24kg/m3, 50mm thick, wrapped in 200 G VirginPolythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @60 cm and wire mesh of 12.5mm x 24g wire and mesh, for top mostceiling of building sqm 24674.00

80 12.50 Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm + 0.05 %, total coated thickness with zinc coating 120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches while transportation and should besupplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required. sqm 9524.21

81 12.51 Providing and fixing precoated galvanised steel sheet roofingaccessories 0.50 mm + 0.05 % total coated thickness, Zinc coating120gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18microns using self drilling/ self tapping screws complete :

12.51.1 Ridges plain (500 - 600mm). metre 1108.0012.51.2 Flashings/ Aprons.( Upto 600 mm) metre 846.0012.51.6 Gutter .(600 mm over all girth). metre 1740.00

82 12.45 Providing and fixing at all height false ceiling including providingand fixing of frame work made of special sections power pressedfrom M.S. sheet and galvanised in accordance with zinc coating ofgrade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide X 1.6 mm thick with flanges of 22 mm and 37 mm at 1200mm centre to centre 1 flange fixed to the ceiling with desk fastner12.5 mm dia X 40 mm long with 6 mm dia bolts to the anglehangers of 25 X 25 X 0.55 mm of required length, end other end ofangle hanger being fixed with nut and bolts to G.I channels 45 X 15X 0.9 mm running at the rate of 1200 mm center to center to whichthe ceiling....Specification and direction of the Engineer-In-Chargebut excluding the cost of painting with...............

12.45.1 12.5 mm thick tapered edge gypsum board conforming to IS: 2095 -Part - I. sqm 5330.00

Total of Schedule Item Roofing work (I) :

FINISHING WORK

Page 19: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

I. Schedule Item83 13.1 12 mm cement plaster of mix :

13.1.2 1:6 (1 cement : 6 fine sand) sqm 38541.90

84 13.2 15 mm cement plaster on the rough side of single or half brick wallof mix :

13.2.2 1:6 (1 cement : 6 fine sand) sqm 38541.68

85 13.16 6 mm cement plaster of mix :13.16.1 1:3 (1 cement: 3 fine sand) sqm 17107.00

86 13.12 18 mm cement plaster in two coats under layer 12 mm thick cementplaster 1:5 (1 cement: 5 coarse sand) and a top layer 6mm thickcement plaster 1:3 (1 cement: 3 coarse sand) finished rough withsponge.

sqm 23203.00

87 13.17 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with afloating coat of neat cement and thick coat of Lime wash on top ofwalls when dry for bearing of R.C.C. slabs and beams. sqm 1858.00

88 13.21 Extra for providing and mixing water proofing material in cementplaster work in proportion recommended by the manufacturers.Perbag of 50 kg cement used in the mix

Kg 4974.00

89 13.23 Extra for plastering on circular work not exceeding 6 m in radius:

13.23.1 In one coat sqm 67030.7813.23.2 In two coats sqm 19926.00

90 13.26 Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete

sqm 59985.00

91 13.37 White washing with lime to give an even shade:13.37.1 New work (three or more coats) sqm 5985.00

92 13.33 Pointing on stone work with cement mortar 1:3 (1 cement: 3 finesand) :

13.33.1 Flush/ Ruled pointing sqm 2286.00

93 13.45 Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and

including priming coat of exterior primer applied @ 2.20kg/10 sqm.

sqm 17800.00

94 13.47 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade

Page 20: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

13.47.1 New work (Two or more coats applied @ 1.43 ltr/ 10 sum. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sum). sqm 335.00

95 13.50 Applying priming coat :13.50.3 3 With ready mixed red oxide zinc chromate primer of approved

brand and manufacture on steel galvanised iron/steel works sqm 49747.0013.50.4 With ready mixed red oxide zinc chromate primer of approved

brand and manufacture on steel work (second coat) sqm 9983.00

96 13.52 Finishing with Epoxy paint (two or more coats) at all locationsprepared and applied as per manufacturer's specifications includingappropriate priming coat, preparation of surface, etc. complete.

13.52.1 On steel work sqm 59730.00

97 13.81 Distempering with 1st quality acrylic distemper, having VOC(Volatile Organic Compound ) content less than 50 grams/ litre, ofapproved brand and manufacture, including applying additionalcoats wherever required, to achieve even shade and colour

13.81.2 Two coats sqm 59985.00

98 13.82 Wall painting with acrylic emulsion paint, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approvedbrand and manufacture, including applying additional coatswherever required, to achieve even shade and colour.

13.82.2 Two coats sqm 13127.00

99 13.62 Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade:

13.62.1 Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture sqm 9099.00

100 26.7 Designing, fabricating, testing, installing and fixing in positionCurtain Wall withAluminium Composite Panel Cladding, with opengrooves for linear as well ascurvilinear portions of the building , forall heights and all levels etc. including:

(a) Structural analysis & design and preparation of shop drawings forpressureequalisation or rain screen principle as required, properdrainage of water tomake it watertight including checking of all thestructural and functional design.

Page 21: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

(b) Providing, fabricating and supplying and fixing panels of aluminiumcompositepanel cladding in pan shape in metalic colour ofapproved shades made out of4mm thick aluminium compositepanel material consisting of 3mm thick FRgrade mineral coresandwiched between two Aluminium sheets (each 0.5mmthick).The aluminium composite panel cladding sheet shall be coilcoated,with Kynar 500 based PVDF / Lumiflon based fluoropolymerresin coating ofapproved colour and shade on face # 1 and polymer(Service) coating on face #2 as specified using stainless steelscrews, nuts, bolts, washers, cleats, weathersilicone sealant,backer rods etc

(c ) The fastening brackets of Aluminium alloy 6005 T5 / MS with HotDip Galvanisedwith serrations and serrated washers to arrest thewind load movement,fasteners, SS 316 Pins and anchor bolts ofapproved make in SS 316, Nylonseparators to prevent bi-metalliccontacts all complete required to perform asper specification anddrawingThe item includes cost of all material & labour component,the cost of all mock upsat site, cost of all samples of the individualcomponents for testing in an approvedlaboratory, field tests on theassembled working curtain wall with aluminiumcomposite panelcladding, cleaning and protection of the curtain wall withaluminiumcomposite panel cladding till the handing over of thebuilding for occupation.The Contractor shall provide curtain wallwith aluminium composite panel cladding,having all theperformance characteristics all complete , as per theArchitecturaldrawings, as per item description, as specified, as perthe approved shop drawingsand as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area sqm 2035.00

101 26.2 Semi-unitized Glazing (design, fabrication and installation )1 Designing, fabricating, testing, protection, installing and fixing in

position semi(grid) unitized system of structural glazing (with openjoints) for linear as wellas curvilinear portions of the building for allheights and all levels, including

a Structural analysis & design and preparation of shop drawings forthespecified design loads conforming to IS 875 part III (the systemmust passedthe proof test at 1.5 times design wind pressurewithout any failure),including functional design of the aluminumsections for fixing glazingpanels of various thicknesses, aluminiumcleats, sleeves and splice platesetc. gaskets, screws, toggles, nuts,bolts, clamps etc., structural and weathersilicone sealants,flashings, fire stop (barrier)-cum-smoke seals, microwavecuredEPDM gaskets for water tightness, pressure equalisation &drainageand protection against fire hazard including:

Page 22: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

b Fabricating and supplying serrated M.S. hot dip galvanised /Aluminiumalloy of 6005 T5 brackets of required sizes, sections andprofiles etc. toaccommodate 3 Dimentional movement for achievingperfect verticalityand fixing structural glazing system rigidly to theRCC/ masonry/structuralsteel framework of building structure usingstainless steel anchor fasteners/ bolts, nylon seperator to preventbimetallic contacts with nutsand washers etc. of stainless steelgrade 316, of the required capacity andin required numbers.

c Providing and filling, two part pump filled, structural silicone sealantandone part weather silicone sealant compatible with the structuralsiliconesealant of required bite size in a clean and controlled factory/ work shopenvironment , including double sided spacer tape,setting blocks and backerrod, all of approved grade, brand andmanufacture, as per the approvedsealant design, within and allaround the perimeter for holding glass.

d Providing and fixing in position flashings of solid aluminium sheet 1mmthick and of sizes, shapes and profiles, as required as per thesite conditions,to seal the gap between the building structure and allits interfaces withcurtain glazing to make it watertight.

e

Making provision for drainage of moisture/ water that enters thecurtainglazing system to make it watertight, by incorporatingprinciples of pressureequalization, providing suitable gutter profilesat bottom (if required), makingnecessary holes of required sizesand of required numbers etc. complete.This item includes cost of allinputs of designing, labour for fabricating andinstallation ofaluminium grid, installation of glazed units, T&P, scaffoldingandother incidental charges including wastages etc., enablingtemporarystructures and services, cranes or cradles etc. asdescribed above and asspecified. The item includes the cost ofgetting all the structural andfunctional design checked and all theshop drawings vetted by the Principalsof the structural glazingsystem.The item also includes the cost of all mock ups at site, costof all samples ofthe individual components for testing in anapproved laboratory, field testson the assembled working structuralglazing as specified, cleaning andprotection till the handing over ofthe building for occupation. In the end,the Contractor shall provide a sqm 2678.00

Page 23: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

102 26.3 Providing, assembling and supplying vision glass panels (IGUs)comprising of hermetically-sealed 6-12-6 mm insulated glass(double glazed) vision panel units of size and shape as requiredand specified, comprising of an outer high performance heatstrengthened float glass 6mm thick, of approved colour and shadewith reflective soft coating on surface # 2 of approved colour andshade, an inner Heat strengthned clear float glass 6mm thick,spacer tube 12mm wide, dessicants, including primary seal andsecondary seal (structural silicone sealant) etc. all complete for therequired performances, as per the Architectural drawings, as perthe approved shop drawings, as specified and as directed by theEngineer-in-Charge. The IGUs shall be assembled in the factory/workshop of the glass processor. (Payment for fixing of IGU Panelsin the curtain glazing is included in cost of item No.1) For payment,only the actual area of glass on face # 1 of the glass panels(excluding the areas of the grooves and weather silicone sealant)provided and fixed in position, shall be measured in sqm. Sqm 2086.40

26.4 Extra for openable side / top hung vision glass panels (IGUs)including providing and supplying at site all accessories andhardwares for the openable panels as specified and of the approvedmake such as heavy duty stainless steel friction hinges, min 4 -pointcremone locking sets with stainless steel plates, handles, buffersetc. including necessary stainless steel screws/ fasteners, nuts,bolts, washers etc. all complete as per the Architectural drawings,as per the approved shop drawings, as specified and as directed bythe Engineer in-Charge. Sqm 1564.80

Total of Schedule Item Finishing work (I) :

I. Schedule Item103 21.1 Providing and fixing aluminium work for doors, windows, ventilators

and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS : 1285, fixed with rawl plugs andscrews or with fixing clips, or with expansion hold fastenersincluding necessary filling up of gaps at junctions, at top, bottomand sides with required PVC/neoprene felt etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beadingfor glazing / panelling, C.P. brass / stainless steel screws, allcomplete as per architectural drawings and the directions ofEngineer-in-charge. (Glazing and panelling to be paid forseparately) :a 21.1.1 For fixed portion.

21.1.1.2 Powder coated aluminium (minimum thickness of powder coating50 micron) kg 3144.90

21.1.1.3 Polyester powder coated aluminium (minimum thickness ofpolyester powder coating 50 micron) kg 183287.13

ALUMINIUM WORK

Page 24: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

b 21.1.2 For shutters of doors, windows & ventilators including providing andfixing hinges/ pivots and making provision for fixing of fittingswherever required including the cost of PVC / neoprene gasketrequired (Fittings shall be paid for separately).

21.1.2.2 Powder coated aluminium (minimum thickness of powder coating50 micron) kg 910.00

21.1.2.3 Polyester powder coated aluminium (minimum thickness ofpolyester powder coating 50 micron) kg 39548.00

104 21.2 Providing and fixing 12mm thick Pre-laminated particle board flatpressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminium doors,windows shutters and partition frames with C.P. brass / stainlesssteel screws etc. complete as per architectural drawings anddirections of engineer-in-charge

21.2.2 Pre-laminated particle board with decorative lamination on bothsides. sqm 3882.00

105 21.3 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with PVC/ neoprene gasket etc.complete as per the architectural drawings and the directions ofengineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item) :

21.3.2 With float glass panes of 5.50 mm thickness sqm 4873.00

106 21.4 Providing and fixing double action hydraulic floor spring of approvedbrand and manufacture IS : 6315 marked, for doors including costof cutting floors as required, embedding in floors and cover plateswith brass pivot and single piece M.S. sheet outer box with slideplate etc. complete as per the direction of Engineer-in-charge.

21.4.1 With stainless steel cover plate each 3.0021.4.2 With brass cover plate minimum 1.25 mm thickness each 14.00

107 21.12 Providing and fixing aluminium tubular handle bar 32 mm outer dia,3.0 mm thick & 2100 mm long with SS screws etc .complete as perdirection of Engineer-in-Charge.

21.12.2 Powder coated minimum thickness 50 micron aluminium tubularhandle bar. each 10.00

108 21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and direction ofEngineer-in-charge complete.

21.8.1 Upto 5mm depth and 5 mm width metre 33189.00

Page 25: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

109 21.17 Providing and fixing anodised aluminium grill (anodised transparentor dyed to required shade according to IS: 1868 with minimumanodic coating of grade AC 15) of approved design/pattern, withapproved standard section and fixed to the existing window framewith C.P. brass/ stainless steel screws @ 200 mm centre to centre,including cutting the grill to proper opening size for fixing andoperation of handles and fixing approved anodised aluminiumstandard section around the opening, all complete as perrequirement and direction of Engineer-in-charge. (Only weight ofgrill to be measured for payment). kg 17253.00

Total of Schedule Item Aluminium work (I) :

I. Schedule Item110 22.1 Providing and laying integral cement based treatment for water

proofing on horizontal surface at all depth below ground level forunder ground structures as directed by Engineer-in-Charge andconsisting of : i) Ist layer of 22mm to 25mm thick approved andspecified rough stone slab over a 25mm thick base of cementmortar 1:3 (1 cement : 3 coarse sand) mixed with water proofingcompound conforming to IS:2645 in the recommended proportionover the leveling course (leveling course to be paid separately).Joints sealed and grouted with cement slurry mixed with waterproofing compound. ii) 2nd layer of 25mm thick cement mortar 1:3(1 cement: 3 coarse sand) mixed with water proofing compound inrecommended proportions. iii) Finishing top with stone aggregate of10mm to 12mm nominal size spreading @ 8 cudm/sqm thoroughlyembedded in the 2nd layer.

22.1.1 Using rough kota stone. sqm 600.00

111 22.2 Providing and laying integral cement based treatment for waterproofing on the vertical surface by fixing specified stone slab 22 mmto 25mm thick with cement slurry mixed with water proofingcompound conforming to IS:2645 in recommended proportions witha gap of 20mm (minimum) between stone slabs and the receivingsurfaces and filling the gaps with neat cement slurry mixed withwater proofing compound and finishing the exterior of stone slabwith cement mortar 1:3 (1 cement : 3 coarse sand) 20mm thick withneat cement punning mixed with water proofing compound inrecommended proportion complete at all levels and as directed byEngineer-in-charge :

22.2.1 Using rough Kota stone sqm 720.00

WATER PROOFING WORK

Page 26: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

112 22.5 Providing and laying water proofing treatment in sunken portion ofWCs, bathroom etc., by applying cement slurry mixed with waterproofing cement compound consisting of applying a) First layer of slurry of cement @ 0.488 kg/sum mixed with waterproofing cement compound @ 0.253 kg/sum. This layer will beallowed to air cure for 4 hours.b) Second layer of slurry of cement@ 0.242 kg/sum mixed with water proofing cement compound @0.126 kg/sum. This layer will be allowed to air cure for 4 hoursfollowed with water curing for 48 hours.The rate includespreparation of surface, treatment and sealing of all joints, corners,junctions of pipes and masonry with polymer mixed slurry.�

sqm 1178.00. 0.00

113 22.6 Providing and laying water proofing treatment on roofs of slabs byapplying cement slurry mixed with water proofing cement compoundconsisting of applying: a) after surface preparation, first layer ofslurry of cement @ 0.488 kg/sqm mixed with water proofing cementcompound @ 0.253 kg/sqm. b) laying second layer of Fibre glasscloth when the first layer is still green. Overlaps of joints of fibrecloth should not be less than 10 cm. c) third layer of 1.5 mmthickness consisting of slurry of cement @ 1.289 kg/sqm mixed withwater proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hoursfollowed by water curing for 48 hours. The entire treatment will betaken upto 30cm on parapet wall and tucked into groove in parapetall around. d) fourth and final layer of brick tiling with cement mortar(which will be paid for separately For the purpose of measurementthe entire treated surface will be measured. sqm 2534.00

114 22.7 Providing and laying integral cement based water proofingtreatment including preparation of surface as required for treatmentof roofs, balconies, terraces etc consisting of following operations:a) Applying a slurry coat of neat cement using 2.75 kg/sqm. ofcement admixed with water proofing compound conforming to IS.2645 and approved by Engineer-in-charge over the RCC slabincluding adjoining walls upto 300mm height including cleaning thesurface before treatment. b) Laying brick bats with mortar usingbroken bricks/brick bats 25 mm to 115mm size with 50% of cementmortar 1:5 (1 cement : 5 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge torequired slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs c)After two days of proper curing applying a second coat of cementslurry using 2.75kg/ sqm of cement admixed with water proofing

Page 27: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

1:4 (1 cement :4 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in toplayer of plaster and finally finishing the surface with trowel with neatcement slurry and making pattern of 300x300 mm square 3mmdeep. e) The whole terrace so finished shall be flooded with waterfor a minimum period of two weeks for curing and for final test. Allabove operations to be done in order and as directed and specifiedby the Engineer-in-Charge :

22.7.1 With average thickness of 120mm and minimum thickness atkhurra as 65 mm. sqm 289.00

Total of Schedule Item Water Proofing work (I) :

I. Schedule Item115 16.15 Supplying at site :

16.15.1 R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size)with wooden plugs or 6mm bar nibs wherever required as perdirection of Engineer-in-charge (cost of earth works in excavation,concrete works in foundation to be paid separately).

cum 20.0016.15.2 Welded steel wire fabric of required width having rectangular mesh

painted with two or more coats of enamel paint of approved shadeover a coat of primer (Priming & Painting to be paid for separately).

kg 129.00

116 16.20 Welded steel wire fabric fencing with posts of specified material andof standard design placed and embedded in cement concreteblocks 45x45x60cm of mix 1:5:10 (1 cement:5 fine sand : 10 gradedstone aggregate 40mm nominal size), every 15th post, last but oneend post and corner post shall be strutted on both sides and endpost on one side only and struts embedded in cement concreteblocks 70x45x50cm of the same mix, provided with welded steelwire fabric fixed between the posts fitted and fixed with G.I. stapleson wooden plugs or tied to 6 mm bar nibs with G.I. binding wire(cost of posts, welded steel wire fabric, painting, earth work inexcavation and concrete to be paid for separately) : sqm 129.00Total Road Work

Subhead I - Sanitary Fixtures117 17.1 Providing & fixing of water closet squatting pan (indian type

w.c.pan) with 100mm sand cast iron P or S trap, 10 liter low levelwhite p.v.c. flushing cistern with manually controlled device (handlelever)conforming to IS:7231,with all fittings and fixtures comleteincluding cutting and making good the walls and floors whereverrequired:

PLUMBING WORKS

Road Work

Page 28: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

17.1.1 White Vitreous china Orissa pattern W.C.pan of size 580x440mmwith integral type foot rests. marked white solid plastic seat and lid.

Each 76.00

118 17.3 Providing & fixing of white vitreous china pedestal type watercloset(European type) with seat and lid, 10 liter low level whiteviterous china flushing cistern C.P.flush bend with fittings &C.I.brackets ,40mm flush bend, overflow arrangment with specialsof standard make and mosquito proof coupling of approvedmunicipala design complete including painting of fittings andbrackets, cutting and making good the wall and Floors whereverrequired:

17.3.1 W.C pan with ISI marked white solid plastic seat and lid Each 133.00

119 17.7 Providing & fixing wash basin with C.I. brackets, C.P brass pillartaps,32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets,cutting and making good the wallswherever required:

17.7.1 White Vitreous China Wash basin size 630x450mm with a pair of15 mm C.P.brass pillar taps. Each 187.00

120 17.10 Providing & fixing stainless steel A ISI 304(18/8) kitchen sink as perI.S 13983 with C.I. brackets and stainless steel plug 40 mmincluding painting of fittings and brackets, cutting and making goodthe walls wherever required: Kitchen sink with drain board.

17.10.1.1 510x1040mm bowl depth 250mm Each 14.00

121 17.11 Providing & fixing white vitreous china laboratatory sink withc.i.brackets.c.p. brass chain with rubber plug 40mm c.p. brasswaste and 40mm c.p.brass trap with necessary c.p.brass unioncomplete including painting and brackets,cutting and making goodthe wall whereever required:

17.11.2 Size 600x450x200mm Each 160.00

122 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basinincluding P.V.C.waste fitting complete.

17.28.2 Flexible pipe17.28.2.1 32 mm dia Each 230.00

123 17.31 Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete. Each 163.00

124 17.71 Providing & fixing PTMT liquid soap container 109mm wide,125mmhigh and 112mm distance from wall of standard shape with bracketof the same materials with snap fittings of approved quality andcolour. weighing not less than 105 gms. Each 230.00

Page 29: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

125 17.73 Providing & fixing PTMT towel rail complete with brackets fixed towooden cleats with C.P brass screws with concealed fittingarangement of approved quality and colour.

17.73.2 600 mm long toil towel rail with total length of 645mm,width 78mmand effective height of 88mm, weighing not less than 190 gms.

Each 104.00

126 17.78 Providing and fixing white vitreous china extended wall mountingwater closet of size 780x370x690 mm of approved shape includingproviding & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etccomplete Each 41.00

127 17.8 Providing and fixing white vitreous china battery based infraredsensor operated urinal of approx. size 610 x 390 x 370 mm havingpre & post flushing with water ( 250 ml & 500 ml consumption),having water inlet from back side, including fixing to wall withsuitable brackets all as per manufacturers specification anddirection of Engineer-in-charge Each 168.00

128 8.10 Providing and fixing stone slab table rubbed, edges rounded andpolished of size 75x50 cm deep and 1.8 cm thick fixed in urinalpartitions by cutting a chase of appropriate width with chase cutterand embedding the stone in the chase with epoxy grout or withcement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth

8.10.2 Granite Stone of approved shade.sqm 168.00

129 18.51 Providing & fixing C.P. brass (Long body)bib cock of approvedquality conforming to IS standerd and weight not less then 690 gms.

18.51.1 15 mm nominal bore Each 67.00

130 18.52 Providing and fixing c.p.brass stop cock(concealed) of standarddesign and of approved make conforming to IS:8931 a)15 mmnominal bore Each 23.00

131 18.65 Providing & fixing PTMT soap dish Holder having length of138mm,breadth 102mm, height of 75mm with concealed fittingarrangements.Weighing not less than 106gms. Each 226.00

132 18.53 Providing and fixing C.P. brass angle valve for basin mixer andgeyser points of approved quality conforming to IS:8931 a) 15 mmnominal bore

a) 15mm nominal bore Each 1039.00

133 18.21 Providing and fixing uplasticised PVC connection pipe with brassunions :

Page 30: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

18.21.2 45 cm length 18.21.2.1 15 mm nominal bore Each 845.00

134 17.34 Providing and Fixing toilet paper holderC.P. brass Each 168.00

135 18.64 Providing and fixing PTMT swivelling shower, 15mm nominal bore.Weighing not less than 40gms. Each 16.00

136 18.49 Providing and fixing C.P.brass bib cock of approved qualityconforming to IS:8931

18.49.1 15 mm nomnal bore Each 32.00

Total Subhead I - Sanitary Fixtures

Subhead II -Internal Drainage (Rainwater,Soil,waste & Fittings )

137 12.37 Providing and fixing 100 mm diameter and 60 cm long rain waterspout in cement mortar 1:4 (1 cement : 4 fine sand).

12.37.1 Stone ware spout each 45.00

138 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with sealring conforming to IS : 5382 leaving 10 mm gap for thermalexpansion.(i) Single socketed pipes.

12.41.1 75 mm diameter (A.S.P.) metre 226.0012.41.2 110 mm diameter metre 731.00

139 18.58 Providing & fixing PTMT grating of approved quality and colour18.58.1 Circular type

18.58.1.1 100 mm nominal dia Each 535.00

140 12.42 Providing and fixing on wall face unplasticised - PVC mouldedfittings/ accessories for unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 5382 leaving 10 mm gap for thermal expansion.

12.42.1 Coupler12.41.1.1 75 mm Each 65.0012.42.1.2 110mm Each 70.0012.42.2 Single Pushfit coupler

12.42.2.1 75 mm Each 40.0012.42.2.2 110mm Each 55.0012.42.3 Single tee with door

12.42.3.1 75X75X75 MM Each 35.0012.42.3.2 110X110X110 MM Each 32.0012.42.4 Single tee without door

Page 31: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

12.42.4.1 75X75X75 MM Each 50.0012.42.4.2 110X110X110 MM Each 55.0012.42.5 Bend 87.5°

12.42.5.1 75 mm bend Each 35.0012.42.5.2 110 mm bend Each 50.0012.42.6 Shoe(plain)

12.42.6.1 75 mm Shoe Each 35.0012.42.6.2 110 mm shoe Each 42.00

141 12.43 Providing and fixing unplasticised -PVC pipe clips of approveddesign to unplasticised - PVC rain water pipes by means of50x50x50mm hard wood plugs, screwed with M.S. screws ofrequired length including cutting brick work and fixing in cementmortar 1:4 (1 cement : 4 coarse sand) and making good the walletc complete

12.43.1 75 mm Each 83.0012.43.2 110 mm Each 95.00

Total Subhead II -Internal Drainage (Rainwater,Soil,waste &Fittings )

Subhead III Internal Water supply

142 18.18 Providing & fixing ball valve ( brass) of approved quality,High orlow pressure, with plastic floats complete:-

18.18.1 15 mm dia nominal bore Nos. 22.0018.18.2 20 mm dia nominal bore Nos. 50.0018.18.3 25 mm dia nominal bore Nos. 40.00

143 18.6 Providing and fixing enclosed type water meter (bulk type)conforming to IS: 2373 and tested by municipal Board completewith bolts , nuts, rubber insertions etc. (The tail pieces if requiredwill be paid separetely).

18.60.3 150 mm dia nominal bore No. 6.00

144 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases andmaking good the same including testing of joints complete as perdirection of Engineer in Charge. Concealed work including cutting chases and making good thewalls etc.

18.8.2 20 mm nominal outer dia .Pipes. Mtr 247.0018.8.3 25 mm nominal outer dia .Pipes. Mtr 335.0018.8.4 32 mm nominal outer dia .Pipes. Mtr 407.00

Page 32: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

145 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.

Internal work - Exposed on wall 18.7.5 40 mm nominal outer dia .Pipes. Mtr 120.0018.7.6 50 mm nominal outer dia .Pipes. Mtr 132.00

146 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings This includes jointing of pipes& fittings with one step CPVC solvent cement ,trenching ,refilling &testing of joints complete as per direction of Engineer in Charge.

External work 18.9.7 62.50 mm nominal inner dia Pipes. Mtr 37.0018.9.8 75 mm nominal inner dia .Pipes. Mtr 19.0018.9.9 100mm nominal inner dia .Pipes. Mtr 16.0018.9.10 150 mm nominal inner dia .Pipes. Mtr 15.00

147 18.59 Providing and fixing C.I. double acting air valve of approved qualitywith bolts, nuts, rubber insertions etc. complete (the tail pieces,tapers etc if required will be paid separately):

18.59.1 50 mm dia Each 20.00

148 18.1 Providing and fixing G.I. pipes complete with G.I. fittings andclamps,i/c cutting and making good the walls etc.

18.10.1 15 mm dia nominal bore Mtr 164.0018.10.2 20 mm dia nominal bore Mtr 249.0018.10.3 25 mm dia nominal bore Mtr 506.0018.10.4 32 mm dia nominal bore Mtr 462.0018.10.5 40 mm dia nominal bore Mtr 711.0018.10.6 50 mm dia nominal bore Mtr 800.00

149 18.4 Painting G.I. pipes and fittings with two coats of anti corrosivebitumastic paint of approved quality.

18.40.1 15mm diameter pipe. Mtr 164.0018.40.2 20mm diameter pipe Mtr 249.0018.40.3 25mm diameter pipe Mtr 506.0018.40.4 32mm diameter pipe Mtr 462.0018.40.5 40mm diameter pipe Mtr 711.0018.40.6 50mm diameter pipe Mtr 800.0018.40.7 65mm diameter pipe Mtr 106.00

Page 33: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

18.40.8 80mm diameter pipe Mtr 137.00

150 18.86 Providing and fixing Stainless Steel pipe and fitting of grade AISI304 as per JIS standard 3448 complete with press type fitting (fittingshall be paid for separately) i/c fixing of the pipe with clamps at1.00m spacing and also including cutting of chases and makinggood the walls including testing of joints complete as per directionof Engineer -in-charge. (The pipe length inserted in the fitting shallnot be measured for payment) Internal work - Concealed Pipe

18.86.1 15.88 mm outer dia .Pipes. metre 536.0018.86.2 22.22 mm Outer dia pipes metre 755.00

151 18.87 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Coupling/Socket18.87.1 For 15.88 mm outer dia pipe each 271.0018.87.2 For 22.22 mm outer dia pipe each 409.00

152 18.88 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of Providing and fixing required Stainless Steel Fitting ofpress fit design of grade AISI 304 conforming toJWWA G116standard with V-profile or M-profile and with O-ring sealing gasket ofEPDM material of required dia as per dirction of Engineer-in-chargeReducer

18.88.1 For 22.22 mm x 15.88 mm outer dia pipe each 122.00

153 18.89 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Slip Coupling/ Socket18.89.1 For 15.88 mm outer dia pipe each 122.0018.89.2 For 22.22 mm outer dia pipe each 100.00

154 18.9 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Elbow 90o18.90.1 For 15.88mm outer dia pipe each 126.00

Page 34: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

18.90.2 For 22.22 mm outer dia pipe each 126.00

155 18.91 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Reducing Elbow 90o18.91.1 For 22.22 mm x15.88 mm outer dia pipe each 162.00

156 18.92 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Equal Tee18.92.1 For 15.88 mm outer dia pipe Each 126.0018.92.2 For 22.22 mm outer dia pipe Each 173.00

157 18.93 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Reducing Tee18.93.1 For 22.22mm x 15.88 mm outer dia pipe Each 126.0018.93.2 For 22.58mm x 15.88 mm outer dia pipe Each 173.00

158 18.94 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Male Thread Tee18.94.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 126.0018.94.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 173.0018.94.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 157.00

159 18.95 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Female Thread Tee18.95.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 125.0018.95.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 150.0018.95.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 122.00

Page 35: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

160 18.96 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Female Thread Connector/ Adapter18.96.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 153.0018.96.2 For 22.22 mm outer dia x 15 mmnominal dia threaded Each 147.0018.96.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 126.00

161 18.97 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Male threaded Connentor/Adapter.18.97.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 133.0018.97.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 126.0018.97.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 173.00

162 18.98 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Valve connector18.98.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 129.0018.98.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 126.0018.98.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 173.00

163 18.99 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Female Threaded Elbow 90O18.99.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 128.0018.99.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 163.0018.99.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 134.00

164 18.1 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Male Threaded Elbow 90O18.100.1 For 15.88 mm outer dia x 15 mm nominal dia threaded Each 129.0018.100.2 For 22.22 mm outer dia x 15 mm nominal dia threaded Each 126.00

Page 36: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

18.100.3 For 22.22 mm outer dia x 20 mm nominal dia threaded Each 173.00

165 18.101 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Cap18.101.1 For 15.88 mm outer dia pipe Each 129.0018.101.2 For 22.22 mm outer dia pipe Each 126.00

166 18.102 Providing and fixing required Stainless Steel Fitting of press fitdesign of grade AISI 304 conforming to JWWA G116 standard withV-profile or M-profile and with O-ring sealing gasket of EPDMmaterial of required dia as per dirction of Engineer-in-charge.

Pipe Bridge18.102.1 For 15.88 mm outer dia pipe Each 112.0018.102.2 For 22.22 mm outer dia pipe Each 132.00

Total Subhead III Internal Water supply

2 SUBHEAD-II : LT CABLE & TERMINATION

2.1 7.7.1

Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of upto 35 sqmm cable on wallsurface as required. (Clamped with 1mm thick saddle)

RM 2965.00

2.2 7.8.1

Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of upto 35 sqmm cable on cabletray as required. (Clamped with 1mm thick saddle)

RM 1070.00

2.3 Cable End TerminationSupply and making End termination with brass compression Glandand Al. lugs for the following size of PVC insulated and PVCshielded/ XLPE Aluminium /Cu. conductor armoured / unarmouredPower cables / wires of 1.1 KV grade as required.

2.3.1 D-9.1.21 3.5C x 35 sq. mm Al. Ar. cable Nos 4.002.3.2 D-9.1.20 3.5C x 25 sq. mm Al. Ar. cable Nos 72.002.3.3 D-9.1.33 4C x 16 sq. mm Al. Ar. cable Nos 36.002.3.4 D-9.1.32 4C x 10 sq. mm Al. Ar. cable Nos 20.00

ELECTRICAL WORKS

Page 37: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

2.4 D-14.3

Filling with available excavated earth (excluding rocks) in trenches,sides of foundations etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer, by ramming & watering, leadupto 50 meters. Cu.M. 44.00

2.5 D-14.6

Excavation of Cable trenches in hard rock not exceeding, 1.5meters in width, and lift upto 1.5 meters, including getting out ofexcavated soil, and disposal of soil as directd within a lead of 50meters. Cu.M. 44.00

2.6

Providing, Laying and fixing following dia RCC pipe NP2 class (lightduty) in ground complete with RCC collars, jointing with cement,mortar 1:2 (1 Cement : 2 fine sand) including trenching (75 cmdeep) and refeling etc as required

2.6.1 D-14.14.1 100 mm dia RM 2735.002.6.2 D-14.14.2 150 mm dia RM 2665.002.6.3 D-14.14.3 250 mm dia RM 2675.00

TOTAL AMOUNT SUBHEAD-II

3 SUBHEAD-III : CABLE TRAY

3.1 Civil-10.2

Structural Steel work revited, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer allcomplete Kg 975.00

TOTAL AMOUNT SUBHEAD -III

4 SUBHEAD-IV : DISTRIBUTION BOARDSupply and fixing of following way, 1 pole / 3 pole & neutral, sheetsteel, MCB distribution board 240/415 volts, on surface / recesscomplete with tinned Cu. Bus bar, neutral bus bar, earth bus bar,DIN bar, detachable gland plate, interconnection, phosphatised &powder painted including earthing etc. as required. ( But withoutMCB/ RCCB/ Isolator)

4.1 Distribution Board (1-phase - 2+12 Way SPN)4.1.1 D-2.3.8 12 Way SPN Double door Nos 10.004.1.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 80.004.1.3 D-2.10.3 40 A DP MCB Nos 10.004.1.4 D-2.14.2 40 A, upto 300mA DP, RCCB Nos 10.004.1.5 D-2.11 Blanking Plate Nos 20.00

4.2 Distribution Board (1-phase - 2+8 Way SPN)4.2.1 D-2.3.7 8 Way SPN Double door Nos 28.004.2.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 168.004.2.3 D-2.10.3 32 A DP MCB Nos 28.00

Page 38: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

4.2.4 D-2.14.1 25 A, upto 300mA DP, RCCB Nos 28.00

4.3 Distribution Board (3-phase - 8 Way TPN)4.3.1 D-2.4.6 8 Way TPN ,(4+24), Double door, Horizontal type Nos 53.004.3.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 1272.004.3.3 D-2.14.3 63 A DP RCCB upto 300mA Nos 141.004.3.4 D-2.14.2 40 A DP RCCB upto 300mA Nos 18.00

4.4 Distribution Board (3-phase - 6 Way TPN)4.4.1 D-2.4.5 6 Way TPN ,(4+18), ) Double door, Horizontal type Nos 50.004.4.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 900.004.4.3 D-2.14.2 40 A DP RCCB upto 300mA Nos 150.00

Supplying and fixing of following ways surface/recessed mountingvertical type, 415 volts, TPN MCB distribution boars of sheet steel,dust protected, duly power painted, inclusive of 200A tinned copperbus bar, common neutral link, earth bar, din bar for mounting MCB's(but without MCB and incomer) as required.

4.5 Distribution Board (3-phase - 4 Way VTPN)4.5.1 D-2.5.4 4 Way TPN ,(4+12), ) Double door, Vertical type Nos 14.004.5.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 168.00

4.6 Distribution Board (3-phase - 8 Way VTPN)4.6.1 D-2.5.5 8 Way TPN ,(4+24), ) Double door, Vertical type Nos 4.004.6.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 72.004.6.3 D-2.10.4 6/32 A S/F"C" series ,TP MCB (Three pole) Nos 8.00

4.7

Supplying and fixing of following ways surface/recessed mountingvertical type, 415 volts, TPN MCB distribution boars of sheet steel,dust protected, duly power painted, inclusive of 200A tinned copperbus bar, common neutral link, earth bar, din bar for mounting MCB'swith provision of 100 amps TP 16 KA MCCB as incomer,interconnection between incomer MCCB and bus bars (but withoutMCB/MCCB) as required

4.7.1 D-2.6.1 8 Way TP Nos 13.004.7.2 D-2.10.1 6/32 A S/F"C" series ,SP MCB (Single pole) Nos 234.004.7.3 D-2.10.4 6/32 A S/F"C" series ,TP MCB (Three pole) Nos 26.004.7.4 D-2.2.1 S/F TPN MCCB (100 AMPS, 16KA) Nos 13.00

TOTAL AMOUNT SUBHEAD -IV

5 SUBHEAD-V : SUBMAIN WIRING

5.1Supplying and laying of the following sizes of 1100 V Grade PVCinsulated FRLS copper conductor wire with PVC conduit ofrequired size complete with terminations.

Page 39: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

5.1.1 D-1.14.4 2 X 6 sq.mm + 1 X 6 sq.mm earth wire RM 430.005.1.2 D-1.14.5 2 X 10sq.mm + 1 X 10 sq.mm earth wire RM 140.005.1.3 D-1.14.6 2 X 16sq.mm + 1 X 16 sq.mm earth wire RM 0.005.1.4 D-1.14.9 4 X 6 sq.mm + 2 X 6 sq.mm earth wire RM 160.005.1.5 D-1.14.10 4 X 10 sq.mm + 2 X 10 sq.mm earth wire RM 1090.005.1.6 D-1.14.11 4 X 16 sq.mm + 2 X 16 sq.mm earth wire RM 420.00

TOTAL AMOUNT SUBHEAD-V

6 SUBHEAD-VI : POINT WIRING

6.1 PVC

Wiring for light / ceiling fan/ Ex. Fan/ Call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVCinsulated copper conductor single core cable etc as required.

6.1.1 D-1.10.3 Group-C Nos 6040.00

6.2 5A PVC

Wiring for 5A Power Plug with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required. (Independent)

6.2.1 D-1.10.3 Wiring for light point- Gr. C Nos 610.006.2.2 D-1.24.4 5 pin 5/6 amp socket outlet Nos 610.006.2.3 D-1.28.1 2 Module Metel Box with base and cover plate Nos 610.00

6.3 5A TwinPVC

Wiring for 5A TWIN Power Plug with 2.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessedPVC conduit, with modular switch, modular plate, suitable GI boxand earthing the point with 2.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.

6.3.1 D-1.14.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire RM 7900.006.3.2 D-1.14.7 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire RM 2660.006.3.3 D-1.17.1 1 x 1.5 sq. mm earth wire in existing conduit RM 7900.006.3.4 D-1.17.2 2 x 1.5 sq. mm earth wire in existing conduit RM 2660.006.3.5 D-1.24.1 6A Switch RM 481.006.3.6 D-1.24.4 5 pin 6A socket outlet Nos 962.006.3.7 D-1.27.4 6 Module Metel Box with base and cover plate Nos 481.00

6.3.8 D-1.26 Supplying and fixing modular blanking plate on existing modularplate & switcg box excluding modular plate required Nos 481.00

Page 40: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

6.4 PVC

Wiring for Ceiling fan point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.

6.4.1 D-1.8.3 Wiring for Ceiling fan point controlled- Gr. C Nos 1819.006.4.2 D-1.25 Stepped type electronic regulator. Nos 1819.006.4.3 D-1.28.1 2 Module Metel Box with base and cover plate Nos 1819.00

6.4.4 Civil-10.18

Providing & Fixing of Circular / hexagonal MS sheet box for ceilingfan clamp of internal dia. 140 mm, 73 mm height , top lid of 1.5 mmthick of MS sheet with its top surface hacked for proper bonding,top lid shall be screwed to the MS sheet box by mens of 3.3 mmdia. round headed screws one lock at the corners. Clamps shall bemade of 12 mm dia. MS bar bent to shape as per standard drawing Nos. 1819.00

6.5

Wiring for light/Power Plug with 2x4 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copperconductor single core cable for loop earthing as required. (forPower socket & AC socket)

6.5.1 D-1.5 Power plug wiring in PVC conduit(2X4 + 1x4 sq.mm) RM 16520.006.5.2 D-1.6 Power plug wiring in PVC conduit(4X4 + 2x4 sq.mm) RM 4400.006.5.3 D-1.24.3 16/20 A Switch Nos 702.006.5.4 D-1.24.5 6 pin 15/16 amp socket outlet Nos 702.006.5.5 D-1.27.2 3 Module Metel Box with base and cover plate Nos 702.00

6.5.6 D-2.19

Supplying & Fixing 20 Amps 240 volts, SPN Industrial type, socketoutlet, with 2 pole and earth, metal enclosed plug topalongwith 20 A`C' series, SP MCB, in sheet steel enclosure, on surface or inrecess, with chained metal cover for the socket outlet and completewith connection, testing & commissioning etc. as required.

Nos 217.00

6.60 PVC

Wiring for Exhaust fan point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box andearthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.

6.6.1 D-1.8.3 Group-C Nos 117.006.6.2 D-1.33 5 amp ceiling rose for Ex. Fan Nos 117.00

6.7

Wiring for light/Power Plug with 2x6sq.mm FRLS PVC insulatedcopper conductor single core cable in surface / recessed PVCConduit alongwith 1 No 6 sq.mm FRLS PVC insulated copperconductor single core cable for loop earthing as required (ForInd Socket)

6.7.1 D-1.14.4 Power plug wiring in Steel conduit(2X6 + 1x6 sq.mm) RM 450.00

Page 41: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

6.7.2 D-1.14.9 Power plug wiring in Steel conduit(4X6 + 2x6 sq.mm) RM 120.00

6.7.3 D-2.19

Supplying & Fixing 20 Amps 240 volts, SPN Industrial type, socketoutlet, with 2 pole and earth, metal enclosed plug topalongwith 20 A`C' series, SP MCB, in sheet steel enclosure, on surface or inrecess, with chained metal cover for the socket outlet and completewith connection, testing & commissioning etc. as required.

Nos 233.00

6.8 Circuit/ submain wiring in PVC conduitWiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of PVC insulated copper conductor, single corecable in surfaec/ recessed PVC conduit as required

6.8.1 D-1.14.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire RM 149140.006.8.2 D-1.17.3 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire in existing conduit RM 57110.00

6.9 D-1.53Supplying and drawing of UTP 4 pair CAT-6 LAN Cable in theexisting surface/ recessed steel/ PVC conduit as required.(forTelephone in Institutional building, Data, PA and FA) RM 28360.00

6.10 D-1.24.6 Modular telephone socket outlet with RJ11 jack .(for Residntial &Ancillairy Buildings) Nos 3.00

6.11 D-1.27.1 2 Module Metel Box with base and cover plate Nos 965.00

6.13

Suppling and fixing of folowing size of PVC conduit along withaccessories in surface reccess including cutting the wall andmaking good the same in case of reccesed conduit as conduit asrequired

6.13.1 D-1.21.1 20 mm RM 27670.006.13.2 D-1.21.2 25 mm RM 15370.00

TOTAL AMOUNT SUBHEAD VI

7 SUBHEAD-VII : LIGHT FIXTURES

7.1 1.41

Installation, Testing & commissioning of pre-wired, fluorescentfitting/ compact flourescent fitting of all types, complete with allaccessories and tube etc. directly on ceiling/ wall, includingconnection with 1.5 sq. mm FRLS PVC insulated, copperconductor. single core cable and earthing etc. as required. Each 5608.00

7.2 1.45

Installation, Testing & commissioning of ceiling fan including wiringthe down rods of standard length (upto 30cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor. single core cable includingproviding and fixing of phenolic laminated sheet cover on the fanbox etc. as required. Each 1854.00

7.3 1.50Installation, of exhaust fan in the existing opening, including makinggood the damage, connection, Testing & commissioning etc. asrequired. Upto 450mm sweep. Each 85.00

Page 42: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

7.40 D-12.34

Supplying and fixing of 32mm dia x 2 meters long G.I pipe (mediumclass) bracket for mounting of fluorescent/HPMV/HPSV street lightfitting on pole/wall including bending the pipe to the required shame2 nos 40 mm x 3 mm flat iron clamps with nuts bolts and washer,painting the flat iron with primer and finish paint etc. as required.

Each 4.00

TOTAL AMOUNT SUBHEAD-VII

8 SUBHEAD-VIII : LIGHTNING PROTECTION

8.1 D-6.2

Providing and fixing of lightning conductor final,made of 25mm dia300mm long,G.I tube,having, Single prong at top, with 85mm dia6mm thick G.I base plate including holes etc. complete as required.

Nos 8.00

8.2 D-6.4Jointing Copper /G.I tape (with another copper/G.I tape, base of thefinial or any other metallic object) by riveting/nut bolting/sweatingand soldering etc as required Nos 1179.50

8.3 D-6.7Providing and fixing G.I tape 20mm X 3mm thick on parapet orsurface of wall for lightning conductor complete as required.(forhorizontal run) RM 3450.00

8.4 D-6.8Providing and fixing G.I tape 20mm X 3mm thick on parapet orsurface of wall for lightning conductor complete as required.(forVertical run) RM 740.00

8.5 D-6.12Providing and fixing testing joint made of 20mm X 3mm thick G.Istrip,125mm long,with 4nos of G.I bolts,nuts,check nuts and springwashers etc complete as required. Nos 53.00

8.6 D-6.14 Providing and laying G.I tape 32mm X 6mm form earth electrodedirectly in ground as required RM 530.00

8.7 D-5.2

Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia includingaccessories, and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc with charcoal orcoke and salt as rerquired. Set 53.00

TOTAL AMOUNT SUBHEAD VIII

9 SUBHEAD-IX : EARTHING9.1 G.I. earth plate electrode

9.1.1 D-5.4

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonary enclosure withcover plate having locking arrangement and watering pipe of 2.7meter long etc. with charcoal/coke and salt as required. Set 20.00

Cu.earth plate electrode

Page 43: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

9.2 D-5.6

Earthing with Cu. earth plate 600 mm X 600 mm X 3 mm thickincluding accessories, and providing masonary enclosure withcover plate having locking arrangement and watering pipe of 2.7meter long etc. with charcoal/coke and salt as required. Set 12.00

9.3 D-5.15 Providing & fixing 25 mm X 5 mm G.I. strip on surface or in recessfor connections etc. as required. RM 480.00

9.4 Copper Tape

9.4.1 D-5.14 Providing & fixing 25 mm X 5 mm CU. strip in 40 mm dia GI pipeform earth electrode as required. RM 40.00

TOTAL AMOUNT SUBHEAD IX

10 POWER BACKUP & LIGHTING CONTROL SYSTEM

10.1 D-15.1

Supplying. Installation, testing and commissioning of PassiveInfrared (PIR) technology based occupancy sensor having highperformance, non regulating programmable, type, suitable forconnected load upto 10Amp, for mounting height up to 2.8 mtr andfor 5m diameter coverage area along with necessary fixingarrangements i/c programming at site etc. complete as required.

Each 99.00

10.2 D-15.2

Supplying. Installation, testing and commissioning of PassiveInfrared (PIR) technology based occupancy sensor with day lightdimming (light level shall be regulated as per availability of naturalday light in an area along with occupancy detection) having highperformance, regulating programmable, type, suitable for connectedload upto 10Amp, for mounting height up to 2.8 mtr. For 5mdiameter coverage area along with necessary fixing arrangementsi/c programming at site etc. complete as required.

Each 345.00

10.3 D-15.3

Supplying. Installation, testing and commissioning of Microwavetechnology based occupancy sensor having high performance, nonregulating programmable, type, suitable for connected load upto10Amp, for mounting height up to 2.6 mtr. and for 5m X 20mcoverage area along with necessary fixing arrangements i/cprogramming at site etc. complete as required.

Each 127.00

TOTAL AMOUNT SUBHEAD-X

13 SUBHEAD XIII : CCTV SYSTEM

13.1 D-1.19

Supply and drawing co-axial TV cable RG-6 grade, 0.7mm solidcopper conductor PE insulated, shielded with fine tinned copperbraid and protected with PVC sheath in the existing conduit asrequired. RM 1080.00

Page 44: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

Quoted RateAmountS.No. DSR 2013 Description of Items Unit Quantity

13.2 D-1.17.3 Supply and Installation of 3 x 1.5sqmm flexible power cable forcamera with all accessories in existing conduit RM 650.00

TOTAL AMOUNT SUBHEAD XIII

14 SUBHEAD XIV : SAFETY EQUIPMENTS

14.1 D- 2.21

Providing and fixing M.V. danger notice plate of 200mm x 150mm,made of mild steel, at least 2mm thick, and vitreous enameledwhite on both sides, and with inscription in single red colour on frontside as required. Each 10.00

Page 45: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)

EARTH WORK

II. Non Schedule Item1 NSI-1 Diluting and injecting chemical emulsion for pre constructional anti-termite

treatment and creating a continous chemical barrier under all round thecolumn pits, wall trenches, basement excavation, top surface plinth filling,junction of wall and floor, along the external perimeter of the building,expansion joints over the top surface of consolidated earth on whichapron is to be laid, sorrounding of pipes and conduits etc. complete asper specifications.( plinth are of the building at ground floor only shall bemeasured in sqm for payment )

With chloropyriphos emulsifiable concentrates of 20 % with 1 %concentration.complete as per direction of Engineer-in-charge. sqm 12,524.00

Total of Non Schedule Item Earth work (II) :

CONCRETE WORK

II. Non Schedule Item2 NSI-2 Providing and laying light weight foam concrete in sunken portion at all

levels as per direction of Engineer-in-charge Cum 446.00

Total of Non Schedule Item Earth work (II) :

WOOD WORKI. Schedule ItemNON -Scheduled Items

3 NSI-3 Providing and fixing of fully insulated 55 mm thick wooden fire / smokecheck door shutter using 31mm thick FR insulation with internal facia of9mm thick calcium silicate board having density not less then 950Kg/cum on both sides and faced with 4mm thick commercial ply facingincluding 15X55 mm size hardwood beading with fire and smoke seal ofsize 10 X4 mm fitted along vertical and horizontal edges of the shutter.The complete door system should be capable to achieve Two hour firerating in accordance with BS:476 Part 20and IS:3614 part II.Rate toinclude 150x75mm Hardwood door frame duly embedded with PromsealIntumscent Smoke Strip as per manufacturer's specification all complete .The door shutter shall also have a vision panel 6mm thk, 200mm x300mm / 300mm x 300mm fire rated glass ( to be paid saperately),surrounded with fire proof treated teakwood beading, all around completein all respects as per manufactures specifications and direction of theEngineer-In-Charge. Sqm 104.00

Non Schedule Items

Construction Of National Institute Of Technology Meghalaya at SohraBill Of Quantity For Package-I (Academic , Admin, Lecture hall, Library, Work Shop, ESS, & Check Dam)

S.No. DSR 2013 Description of Items QuantityUnit Quoted Rate Amount

CIVIL WORKS

Page 46: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

4 NSI-4 Providing & Fixing following fire rated fittings as per manufacturesspecifications and direction of the Engineer-In-Charge.

A Door Locks Each 30.00 B Glass Wired Vision Panel of size 200mmx300mm Each 30.00 C Door Closer Each 30.00 D SS door Handles 150 mm Each 60.00 E SS tower Bolts 300 mm Each 30.00

Total of NON Schedule Item Wood & PVC Work (II) :

S T E E L WORK

II Non Scheduled Item5 NSI-5 Extra and above for using galvanised structural steel ubes/members in

trusses in place of MS structural steel tubes/members (min thickness ofgalvanised coating will be 15 microns)

kg 1,203,309.00

FLOORING WORK

II Non Scheduled Item

6 NSI-6 Granite stone flooring with 18mm thick stone (sample of granite shall beapproved by Engineer-in-charge) over 20 mm (average) thick base ofcement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with greycement slurry including rubbing and polishing complete with :

Sqm 10,957.00

7 NSI-7 Granite work gang saw cut (polished and machine cut) of thickness18mm for wall lining,skirting and dado (veneer work) in cement mortar1:3 (1 cement : 3 coarse sand) including pointing with white cementmortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigmentto match the marble shade: (To be secured to the backing by means ofcramps, which shall be paid for separately). complete as per direction ofEngineer-in-charge Sqm 8,163.00

8 NSI-8 Providing Flamming on granite stone slabs in floors, landing and treadscomplete including required material for the purpose as per direction ofEngineer-in-charge. Sqm 1,698.00

Page 47: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

9 NSI-9 P&F flexible PVC sheet flooring in 2.0mm thickness in the size of2mx20mtr use area classification 23/34/43. Results from independenttesting demonstrate that product inherently inhibits the growth of microbialstrain MRSA. It shall be homogeneous single layer and monolayer inconstruction, and shall be manufactured by calendering and presssing, toensure a dense & smooth. The flooring shall incorporate a speciallyformulated polyurethene reinforcement, to give life long polish freemaintenance. Homogeneous PVC Vinyl flooring(imported) with totalweight 3250 g/m2 polyurethane reinforced (PUR) ,Abrasion groupP:≤0.15mm,residual identification approx..01 mm,castor wheel testqualified,,dimensional stablity EN-434,static electrical charge <2kv,impact sound reduction approx ,good resistance of scratch,slip,chemical and firedoesn't favour in growth of fungi & bacteria ,BREcertified. class 'A' ( Polyflor Mystique PUR) / Equivalent complete as perdirection of Engineer-in-charge. sqm 489.00

10 NSI-10 Providing of 3 mm average thick layer of cementitious salt smoothningcompound of Ardex CL-11 or equivalent as recommended by the Vinylsheet flooring manufacturer over and including a priming compound ofArdex P-51 or equivalent as recommended by the Vinyl sheet flooringmanufacturera on concrete surface to provide a smooth & homogenoussurface for laying of vinyl sheet flooring complete to the entire satisfactionof Engineer-in-charge.

sqm 6,533.00

11 NSI-11 P&F flexible PVC sheet wall cladding in 1.25 mm thickness in the size of1.83x30mtr with polyurethane surface treatment,with the testing results ofinhibits the growth of MRSA in the walls with the clean room certificatiom.HomogeneousPVC Vinyl wall covering (imported) with total weight 2120g/m2 polyurethene sheild,dimentional stablity ≤0.40%,wetroom testqualified,good resistance to chemical & fire,anti fungi & bacterialgrowth,class A in clean room test and available in various colour shade. (polyflor polyclad PU) / Equivalent

sqm 300.00

12 NSI-12 Providing and Fixing carpet (tip shared loop pattern/pattern cut pile orpattern scrol) make of yarn content avalar/Aqua approved SD nylon withpuralex/continuous filament 6.6 nylon, yarn weight 26 to 36 oz/sq yd, withprimary backing of master line/polypropylene and secondary backing ofwovan polypropulene with post consumer recycled content. 1/8, 1/10 and1/12 guage, 7.3 to 14 stotches/inch, the carpet shall be flame resistant asper DOC FF-I-70 smoke density should be less than 450 (ASM E-662)soil resistant as epr commercial anti soil protection and carpet is CRIgreen label plus certified # GLP7078 the carpet shall be pasted withappropriate adhesive suitable for pasting on existing floor, complete jobas per manufacturer's specifications (Equivalent to AquaHospitality/Equavalent) complete as per direction of Engineer-in-charge.

sqm 5,965.00

Total Non -Scheduled

Page 48: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

ROOFING WORK

NON -Scheduled Items

13 NSI-13 Providing & Fixing of Mineral Fibre Suspended Ceiling System with(Tegular) EDGE TILES WITH 24mm Exposed GRID. The tiles shouldhave Humidity Resistance (RH) of 99%, Minimum NRC 0.5, LightReflectance ≥83%, Thermal Conductivity k = 0.052 - 0.057 w/m K, FirePerformance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of600 x 600 x 16mm with Bio Block coating on the face of the tile, suitablefor Green Building application, with Recycled content of 38 - 41%. The tileshall be laid on with 24 mm wide T - section flanges having rotarystitching on all T sections i.e. the Main Runner, 1200 mm & 600 mmCross Tees with a web height of 38mm and a load carrying capacity of15.34Kgs/M2. The T Sections have a Galvanizing of 90 grams per M2 .The Tile & Grid system used together should carry a 15 yearwarranty.Installation to comprise main runner spaced at 1200mm centressecurely fixed to the structural soffit using suspension system(specifications below) at 1200mm maximum centre. The First/Lastsuspension system at the end of each main runner should not be greaterthan 450mm from the adjacent wall. Flush fitting 1200mm long crosstees to be interlocked between main runners at 600mm centre to form1200 x 600 mm module. Cut cross tees longer than 600mm requireindependent support. 600 x 600mm module to be formed by fitting600mm long flush fitting cross tees centrally between the 1200 mm crosstees.Perimeter trim to be wall angles of size 3000x19x19mm, secured towalls at 450 mm maximum centres complete as per direction of Engineer-in-charge.SUSPENSION SYSTEM accessories will be approved make consistingof M6 Anchor Fasteners or equivalent with Vertical Hangers made ofGalvanised steel of size 26 x 26 x 25 x 1.2mm with a GalvanisedThickness of 80gsm, A pre Straightened Hanger wire of dia – 2.68 mm of1.83 m length., thickness of 80gsm and a tensile strength of 344-413MPa, along with Adjustable hook clips of 0.8mm thick, galvanised springsteel for 2.68 mm with a minimum pull strength of 110 kg. The adjustableclip also consists of a 3.5 mm aquiline wire to be used with the mainrunner. The work including, , cutting / making, opening for services likediffusers, grills, light fittings, fixtures, smoke detectors etc wherever,required.completed as per direction of Engineer-in-charge.

Sqm 20,283.00

Page 49: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

14 NSI-14 Providing & Fixing of in metal ceiling System consisting of 600x600mmclip in tiles of pre coated Aluminium in 0.7 mm thickness with bevel edgein white colour with standard perforation of 1.5mm dia. The back of thetile should have black acoustical fleece. The NRC should be 0.70 andsuitable for Green Building application, with Recycled content of 50%.Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mmcentres securely fixed to the structural soffit by support clamp & approvedhangers. The last hanger at the end of each C channel should not begreater than 600mm from the adjacent wall. Use a C-channel connectorfor splicing two pieces of C-channels. 4000mm Dp-12 Main carriers(spring tee bars) shall be spaced at 1200mm centres in a directionperpendicular to the C-channels and shall be secured at everyintersection with C channel using a dp-12 hanger. Use Dp-12 connectorto splice two pieces of Dp-12 main carriers. Tiles should be clipped inbetween two Dp-12 carriers (spring tee bars) from below. Perimetertrims to be of Armstrong wall angles of white colour secured to walls at450mm maximum centres. Cut tiles to be secured to the wall anglesusing a spring clamp complete as per direction of Engineer-in-charge.

Sqm 2,262.00

15 NSI-15 Providing and fixing wooden false ceiling consisting well seasoned hardwood sections, treated with preservatives, minimum 50x50 mm, atsuitable horizontal/vertical spacing not exceeding 600 mm c/c.applyingfinished with 1 mm thick laminate of same or combination shades ofapproved brand over 12 mm thick BWR grade ply with grooves / patternall complete as per drawings and direction of Engineer-in-charge,including, cutting / making, opening for services like diffusers, grills, lightfittings, fixtures, smoke detectors etc wherever, required.

Sqm 531.00

16 NSI-16 Extra for using 4 mm veneer in place of laminate on wooden false ceilingincluding additional framing as per direction of Engineer-in-charge.

sqm 931.00

17 NSI-17 Supply and fixing of Aluminium Standing Seam 65/400 “SELFSUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mmTHICK AA 3004 ALUMINIUM ALLOY. The general roof-constructionshall comprise from bottom to top:Steel Liner – 32-35/250 Bare Galvalume steel liner sheet, 0.5 mm tct1000 mm total cover width x 32-35mm deep ribs spanning up to 1500mmcentres (multiple spans). Vapour Control Layer – A single layer of double-sided aluminium foil/Polyethylene Film.Insulation - A layer of Rockwool insulation of 100mm thickness minimum48kg/m3 density with thermal conductivity of K=0.04 W/mk at 25 degreeCelsius. Fire classification with test procedures to BS 476: Parts 6 & 7.

Page 50: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

Top layer – Aluminium Standing Seam 65/400 straight profile sheetingmanufactured from aluminium self supported standing seam roof systemmanufactured from aluminium alloy AA 3004 (AlMn1Mg1) as specified inBS EN 1396: 2007 minimum material thickness of 0.9 mm andFluorocarbon PVDF finish on the exposed surface. The system includesall the Accessories, Fasteners and Top-hat.

The profiles sheets to be used must be long length sheets and should notbe with any lapping joints. To achieve long length sheets dedicated rollforming machines to be usedThe roofing system shall be certified with a British Board of AgreementCertificate No 98/3481 plus the Institute of BautechnicZulassungbeschield N R -14.1 .181 The approved roofing system mustalso be certified by the Factory Mutual FM Research Corporation of theUSA and classified as a CLASS 1 Panel Roof. The manufacturer mustproduce all 3 valid certifications.complete as per direction of Engineer-in-charge Sqm 18,964.00

18 NSI-18 Flashings as per the specifications above and 0.9mm thick AluminiumPVDF Finish complete as per direction of Engineer-in-charge.

RM 4,500.00

19 NSI-19 Providing and fixing 15mm thick Mineral Fibre False Ceiling with Tiles ofsize 600 x 600mm in true horizontal level suspended on inter lockingmetal grid of hot dipped galvanied steel sections (galvanized @ 170gsm/sqm) consisting of main "T"runner suitably spaced at joints to getrequired length and of size 24x38mm made from 0.30mm thick(minimum) sheet spaced at 1200mm centre to centre and cross "T" ofsize 24x25mm made of 0.30 mm thick (minimum) sheet to be interlockedat middle of the 1200x600mm panel to form grids of 600x600mm andlaying 15mm thick mineral fibre false ceiling files of approved texture inthe grid including, wherever, required, cutting / making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc.main "T" runners to be suspended from ceiling using GI slotted cleatsfixed to ceiling with 6mm dia and 50mm long dash fasteners,4mm GIadjustable rods with galvanized level clips spaced at 1200m centre tocentre along main T, bottom exposed width of 24mm of all T-sectionsshall be pre-painted with polyester paint, and The mineral fibre ceilingshall either be

precast (moulded) or wetted product and shall have NRC value of0.5(minimum) CAC 35-39, light reflection 84% (minimum), fire ratingclass A as per ASTM E-84, suitable for 95% relatie humidity and alsohaving thermal resistance "(R)" = 0.33sqm deg. C/W,all complete at allheights as per manufacturers specifications, drawings and direction ofEngineer-in-charge complete as per direction of Engineer-in-charge.

Sqm 1,292.00

Total of NON Schedule Item Roofing Work (II) :

Non Scheduled Items

FINISHING WORK

Page 51: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

20 NSI-20 Slate tile work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) ans cement slurry @ 3.3 Kg/Sqm including pointing in white cement complete as per the directions of engineer-in-charge. Sqm 5,085.00

21 NSI-21 Bhuj block tile (stone look) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) ans cement slurry @ 3.3 Kg/Sqm including pointing in white cement complete as per the directions of engineer-in-charge. Sqm 5,085.00

22 NSI-22 Providing & Fixing Chicken Mesh on the junction of R.C.C work & brick work under the plaster by U nail. Complete as per direction of Engineer in charge. Sqm 24,740.00

23 NSI-23 Ceiling :- Providing and fixing of acoustical ceiling with perforated Tile Square edge 8mm for Ceiling of size 595x595/1195x 8mm is to be installed on framework of T-24 GI grid. This system has NRC upto 0.80 with humidity resistance of 99% RH and light reflectance upto 74% with Green Performance certified. Magnesia perforated Tile having 6mm dia perforation with acoustical fleece on back side of Tile and it meets the stringent fire test required having Class A1 rating , with complete framework as per Installation details given as per the directions of engineer-in-charge.Installation Details:- acoustical ceiling with perforated Tile Black Square edge 8mm for Ceiling Tile is to be layed on frame work of T-24 grid pre-coated GI angle size 24x24x0.4 mm thick fixed to the brick wall / partition at the perimeter of ceiling with Nylon Sleeves and drywall screws, Then suspended main GI ‘T’ section (bottom precoated-white) with polyester coating of 25 microns dry film thickness. Main T-section size 24x38x0.3 mm thick and 3600 mm long from soffit in one direction with the help of metal rawl plug, cleat, leveler, perimeter & wall spring clip & G I Rod 4 mm diameter with galvanized spring steel level clip 1200 mm centres from soffit. G I cross T section (bottom precoated-white) size 24x25x0.3 mm and 1200mm & 600mm long is insert fixed into the slots provided as interlock in main ‘T’ at 600 mm centres to form 600x600mm grid size for a tile size of 595x595 mm. All accessories such as framework accessories cleat, suspenders, levelers, clips etc, shall be supplied and installed in accordance with manufacturer recommendation. Complete as per the directions of engineer-in-charge.

Sqm 3,225.00

Page 52: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

24 NSI-24 Wall (Dado Height) :- Providing and fixing acoustical wooden Grooves panel having system NRC upto 0.75 with lineal perforations.The panels shall be fire resistant (FR) grade with melamine laminate panels 2430mm x 128mm x16mm with 2mm slats at 16/32 mm pitch, Toungue and Groove edges for seamless mounting having density of 750 kg/m3 . The back of the panels are perforated with 10mm diameter circular holes with acoustical fleece of 0.2mm for providing Sound absorption via the acoustic impedance method.Panel is fixed by using CC225 GI Frameworkspaced at 600mm centers & steel keel 18mm of aluminum/GI framework spaced at 400mm centers with suitable brackets and the system is backlined with polyster fibre of 25mm with surface density of 1000 gsm and alongwith all accessaries and direction of Engineer in charge.

Sqm 1,559.00

25 NSI-25 Wall (Above Dado Height) :- Providing and Fixing acoustical Panel of size 2400/1200x600x25 mm of 400kg/m3 density with Spline H. Which will comprise to NRC upto 0.9. Earcons Celia Stuff Panel is to be installed on GI SC 48 framework.The system shall meet the fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476 part 6 Fire Propagation index with complete GI frame work as per Installation details givenInstallation:- The acoustical Panel is to be fixed on GI floor and ceiling channel & stud of G I section of prime quality cold rolled steel as per IS 513 hot dipped galvanized 120 gsm as per BS 2989 and zinc coating as per IS 277. The GI SC-48 wall channel and FC-50 floor and ceiling channel are to be fixed with nylon plastic sleeves and wooden screws to from the proper framework . The extra channel must be used at openings and junctions as required.The Polyester Fiber of 50mm with 1000 gsm surface density should be inserted in cavity of the framework for better insulation.The stud will come at every 600 centre to centre & Spline H to be fixed perpendicular to the SC-48 channels with steel screws for fixing Acoustic Panel in plumb, line & level. As per the specification and direction of the Engineer incharge. Sqm 1,650.00

Total Non Scheduled Items

Non Scheduled Items26 NSI-26 Providing & fixing SS wire gauge of average width of aperture 1.4 mm

with wire of dia 0.63 mm for aluminium doors/window fixed with nessecaryscrew / washer complete in all respects as per direction of Engineer-In-Charge. sqm 3,833.00 Total of Non Schedule Item Aluminium work (II) :

Non DSR Item

ALUMINIUM WORK

Road Work

Page 53: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

27 NSI-27 Trimming of side Check Dam by chigeling of stone and filling of pot holsany by CC - 1:2:4 (1 Cement : 2 Course Sand : 4 Grade Stone 20mmSize) to give a smooth surface complete as per direction Engineer incharge. Sqm 700.00 Total

Subhead I - Sanitary Fixtures

28 NSI-28 Providing and fixing C.P. brass twin coat hooks fixed on toilet door withC.P. brass screws complete as per direction of Engineer -in-charge.

Each 230.00

29 NSI-29 Providing and fixing 15 mm dia C.P. Ablution health faucet with 1.0 mlong SS extension pipe with wall hook and operating knob complete in allrespects as per direction of Engineer -in-charge. Each 168.00

30 NSI-30 Providing & fixing solid state, no touch operting, fully hygienic hand drierof approved shade with blower, continuous repeat usage, time delay,summer & winter control, music while drying, volume ON/OFF controlsincluding providing necessary bracket cable from drier to plug, plug topkey and lock etc. complete as per direction of Engineer -in-charge.

Each 66.00

31 NSI-31 Providing & fixing C.P. brass basin Mixer Tap with aerator complete asper direction of Engineer -in-charge. Each 230.00

32 NSI-32 Providing & fixing C.P. brass sink Mixer Tap with aerator complete as perdirection of Engineer -in-charge. Each 160.00

33 NSI-33 Providing & fixing in position of white vitreous china below counter washbasin / circular / oval with C.I. brackets painted white, 32 mm dia C.P.brass waste, 32 mm dia C.P. cast brass bottle trap, including cuttingand making good the walls and floors where required complete as perdirection of Engineer -in-charge. Each 43.00

34 NSI-34 Providing & fixing C.P. brass air purifier container fixed to wooden / PVCcleats with C.P.brass screws complete as per direction of Engineer -in-charge. Each 244.00

35 NSI-35 Providing & fixing in position storage type Hot Water electrical horizontalGyser with M.S. jacket, thermostatically controlled immersion heater,with pilot lamp, 15/20mm dia inlet and 15/20mm dia outlet includingmaking connections complete in all respects as per direction of Engineer -in-charge. (wall mounted with suitable M.S. bolts and nuts)

Capacity 15 litres Nos. 34.00Capacity 25 litres Nos. 50.00NOTE:

PLUMBING WORKS

Page 54: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

Detail of Sanitary fixture are for the information of the Contractor,howevermodel/makes of all sanitary fixtures shall be selected by Architect/Projectmanager and the same shall be binding for execution.

Total Subhead I - Sanitary Fixtures

Subhead II -Internal Drainage (Soil,waste & Fittings )36 NSI-36 Providing and fixing, uPVC pipes 6 Kg/Cm2 (IS: 4985 ) including all

fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointingwith rubber ring/solvent cement joints including required suports,cuttingchase or holes in walls and floors and making good where required (forsoil & waste pipes, ASP pipe) complete as per direction of engineerincharge75 mm OD. Mtrs. 50.00110 mm OD. Mtrs. 2885.00160 mm OD. Mtrs. 50.00200 mm OD Mtrs. 190.00

37 NSI-37 Providing & fixing in position uPVC P"or S" trap of self cleaning design offollowing sizes for the embedded areas. Making proper connection withdrip-seal joints, cutting chase / hole in floors /slabs and bringing the samein proper condition in cement concrete 1:2:4 mix complete as required.including cost of cutting and making good the walls and floors whererequired, complete as per direction of Engineer -in-charge.

110 mm inlet and 110 mm outlet Each 321.00100 mm inlet and 50 mm outlet (Floor Drains only). Each 206.00

38 NSI-38 Providing and fixing pvc pipes conforming to relevent I:S including allfittings, testing, cutting holes or chases and making good where requiredcomplete as per direction of Engineer -in-charge. (For wasteconnections).32mm dia (8 kg/cm2) Mtr. 511.0050mm dia (6 kg/cm2) Mtr. 590.00

39 NSI-39 Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or50 mm size fabricated from 100/150 mm dia upvc pipes andsockets,fixed to p trap with solvent joint and set in cement concrete as perstandard drawing complete as per direction of Engineer -in-charge.

Each 32.00

40 NSI-40 Providing and fixing END CAP or cleanout plug( Ceiling or Floor) withsuitable inset keys for opening, male threaded joint with socket fixed touPVC/SCI pipe complete in all respects as per direction of Engineer -in-charge.110 mm nominal pipe size Each 243.00

Page 55: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

41 NSI-41 Providing and fixing on wall face unplasticised PVC (working pressure for4 Kg/cm2) rain water pipes comforming to IS: 4985 including jointing withseal ring conforming to IS : 5382 leaving 10mm gap for thermalexpansion complete as per direction of Engineer -in-charge.

Mtr. 350.00

Total Subhead II -Internal Drainage (Soil,waste & Fittings )

Subhead III Internal Water supply

42 NSI-40 Providing & fixing butterfly valve tested to a pressure of 15 Kg/Sq.cm.Including rubber gasket, flanges, nuts, bolts, washers & painting completeas per direction of Engineer -in-charge.65 mm dia No. 14.0080 mm dia No. 4.00100 mm dia No. 12.00

43 NSI-43 Providing and fixing in position of approved quality G.M. float valvewith copper ball float and brass rods of required length suitable forpressure of 10 Kg/sqcm of the following sizes, complete as per directionof Engineer -in-charge:50 mm dia No. 20.00

44 NSI-44 Providing and fixing G.I. pipe headers in various length conforming toIS:1239 heavy class including all flanged connections as per drawing /site requirement. Supports from wall, floor and ceiling etc. Includingdead end flanged connection,MEDIUM CLASS, complete as per directionof Engineer -in-charge.65 mm dia RM 177.0080 mm dia RM 153.00100 mm dia RM 99.00

45 NSI-45 Providing and Fixing full way lever operated forged brass ball valve ofbrass body with forged brass hard chromeplated steel ball tasted to apressure not less than 15 kg/sqcm with threaded / flanged joints completewith nuts, bolts, gaskets, washers etc. complete as per direction ofEngineer -in-charge32 mm dia Nos. 54.0040 mm dia Nos. 22.0050 mm dia Nos. 26.00

46 NSI-46 Providing & fixing gun C.I. non-return valve of approved make with unionflange/screwed end,washer,nut & bolts,suitable for pressure not less than15 kg/cm2 & for tempretur upto 85 ' C including nitril rubber insulationcomplete as per direction of Engineer -in-charge.65 mm dia Nos. 1.0080 mm dia Nos. 1.00100 mm dia Nos. 10.00150 mm dia Nos. 1.00

Page 56: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

47 NSI-47 Providing and fixing pressure Reduce valve from 6kg/cm2 to 4kg/cm2 asper IS including nuts and bolts complete in all respects as per direction ofEngineer -in-charge.15 mm dia Nos. 7.0020 mm dia Nos. 2.0025 mm dia Nos. 2.0032 mm dia Nos. 2.0040 mm dia Nos. 2.0050 mm dia Nos. 2.0065 mm dia Nos. 2.00

48 NSI-48 Painting GI. Pipes and fittingswith two or mote coats with syntheticenamel white paint over a ready mixed priming coat, both of approved fornew work.complete as per direction of Engineer -in-charge

RM 100.00

Total Subhead III Internal Water supply

Subhead IV - Miscellaneous Items

49 NSI-49 Providing and fixing M.S. puddle flanges fabricated out of 6 mm thickM.S. plate of size 200 x 200mm plus dia of pipe of 750 mm long pipepieces to R.C.C. water tanks / R.C.C. walls. The entire fitting shall be hotdipped galvanised complete as per direction of Engineer -in-charge.

100mm dia Nos. 62.0080mm dia Nos. 35.0065mm dia Nos. 45.0050mm dia Nos. 68.0025mm dia Nos. 25.00

Total Subhead IV - Miscellaneous Items

Sub Head-A: Piping, Hydrant and Accessories System50 NSI-50 Providing, laying, jointing and testing of following sizes of pipes

conforming to IS-1239 with all accessories like all fittings including tees,elbows, reducers, flanges, rubber gaskets, nuts bolts, washer. Andfixing the pipe on floor / wall /ceiling with suitable size clamps,hangers, structural steel supports as per specification. And G.I. pipesleeve to be provided wherever the pipes are crossing the walls/floorsand sealing the sleeves as per consultants requirements including cuttingholes and chases in brick, R.C.C work and making good the same tooriginal conditions complete in all respects. Pipe shall be MS black as perIS-1239 heavy grade and fitting for 40 mm and below be of forgedscrewed fittings and above BW 'C' class fittings complete as per directionof Engineer -in-charge.

For Fire System - M.S. `C' Heavy class pipe

FIRE FIGHTING WORK

Page 57: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

25 mm dia RM 121.0032 mm dia RM 124.0040 mm dia RM 7.0050 mm dia RM 203.0065 mm dia RM 7.0080 mm dia RM 7.00100 mm dia RM 6.00150 mm dia RM 805.00

51 NSI-51 Providing two coats of synthetic enamel paint of approved shade over acoat of primer. Including painting of legends both direction arrow as perthe approval of the architects / consultants complete as per direction ofEngineer -in-charge.25 mm dia RM 121.0032 mm dia RM 124.0040 mm dia RM 7.0050 mm dia RM 203.0065 mm dia RM 7.0080 mm dia RM 7.00100 mm dia RM 7.00150 mm dia RM 805.00

52 NSI-52 Providing, laying, jointing and testing in trenches the following sizes ofM.S. class `C' (heavy class) pipes conforming to IS:1239 with accessorieslike fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I.nuts, bolts and washers and providing 150mm thick fine sand layer allaround the pipe, including excavation in all kind of soil/ hard rock, refilling,ramming and removing the excavated surplus material and making goodthe same complete as required.and providing anti corrosive treatment(coating and wrapping) with 4 mm thick anti corresive tape as per IS:10221 complete as required as per direction of Engineer -in-charge. (forexternal works)

80 mm dia RM 7.00150 mm dia RM 7.00

53 NSI-53 Providing and fixing Orifice plate made out of 8mm thick stainless platefor pipe to reduce pressure upto 3.5 kg/sqcm complete in all respects asper direction of Engineer -in-charge150 mm dia Nos. 73.00

54 NSI-54 Providing and fixing gun metal ball valve suitable for pressure 15 Kg/Cm2and confirming to IS: 778 of the following size including providingnecessary union / flange complete as per direction of Engineer -in-charge.25 mm dia Nos. 73.00

55 NSI-55 Providing & fixing of butterfly valve suitable for pressure 15 Kg/Sqcm.with flanges, nut bolts & gaskets complete as required as per directionof Engineer -in-charge.150 mm dia Nos. 20.00

Page 58: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

56 NSI-56 Providing & fixing cast iron Slim seal dual type non-return valves (PN1.6)complete with matching flanges, rubber insertion, nuts, bolts and washercomplete as required of following sizes complete as per direction ofEngineer -in-charge.150 mm dia Nos. 20.00

57 NSI-57 Providing & fixing Air Cushion tank (Air - vessel) 250 mm dia x 1.0 Mhigh with dished top made of minimum 6 mm thick M.S Sheet pipe/ platecomplete with 25 mm dia brass . Air Valve (Ball type) 25 mm diastopcock. Nipple tees. Elbows and all accessories as required includingfixing brackets complete as per direction of Engineer -in-charge.

Nos. 10.00

58 NSI-58 Providing & fixing double flanged flexicon rubber expansion joint with unitcontrol of standard length as per maufacturers specs. Tested to apressure of 15Kg/Sqcm including rubber gaskets, flanges, nuts, bolts andwashers complete as per direction of Engineer -in-charge.

150 mm dia Nos. 10.00

59 NSI-59 Supply, Installation, Testing & Commissioning of Single headed,Gunmetal ISI marked oblique pattern hydrant landing valve with 80 mmdia flange inlet and 63 mm dia instantaneous type female out let completewith gunmetal cap and G.I chain twist release type plug and allaccessories as per IS:5290-1983 (Type A) complete as per direction ofEngineer -in-charge Each 73.00

60 NSI-60 Providing & fixing swinging type First Aid hose complete as per directionof Engineer -in-charge. Nos. 73.00

61 NSI-61 Providing & fixing Non per colating flexible hose (RRL type – A) ISImarked (IS:636 Type A) 63 mm dia x 15 m long complete with ISI markedMale and female coupling (IS:903) bound and riveted to hose pipe withcopper rivets and 1.5 Sq.mm.copper wire.brusting pressure not lessthan 22 Kg/Sqcm. (two nos. for each hydrant-valve) complete as perdirection of Engineer -in-charge Each 146.00

62 NSI-62 Providing & Fixing Gun-metal 63 mm dia short size branch pipes with 20mm dia nozzle with 63 mm instantaneous coupling ISI marked (IS:903)complete as per direction of Engineer -in-charge. Each 73.00

63 NSI-63 Providing and fixing standard firemans axe with heavy rubber handlecomplete as per direction of Engineer -in-charge. Nos. 73.00

64 NSI-64 Providing and fixing inlet breeching having C.I. body Two way gun metal63 mm dia instantaneous inlets conforming to IS 903 fitted with non returnvalves, 25 mm dia gun metal drain cock, blank cap, brass chains and150 mm dia flanges with all accessories suitable for local fire tendercomplete as required in Down Comer Riser complete as per direction ofEngineer -in-charge. Nos. 10.00

Page 59: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

65 NSI-65 Providing and fixing 4mm thick glass door of size 2.1m x 0.9m withanodized aluminium frame of size 0.10 x 0.05 M with centre opening forfire hose cabinet. Suitable marked on the outside with the letters "FIREHOSE" including locking arrangement. All aluminium work to be in RedP.O. colour complete as per direction of Engineer -in-charge.

Nos. 73.00

66 NSI-66 Providing and fixing Carbon-di-oxide fire extinguishers consisting ofwelded M.S cylinderical body,squeeze lever discharge valve fitted withinternal dischargetube,30cms long high pressure dischargehose,discharge nozzle, suspension bracket, confirming to IS : 934finished externally withred enamel paint and fixed to wall withbracketswith rawl plug/dash fasteners complete with internal charge complete asper direction of Engineer -in-chargeCapacity 4.5 Kg Nos. 73.00

67 NSI-67 Providing and fixing water Co2(ISI marked) extinguishers including allaccessories as per IS specification. (IS 934) with wall bracket with rawlplug complete as per direction of Engineer -in-charge.9 K.g Each 73.00

Total Fire Fighting

1 SUBHEAD-I : ELECTRICAL PANELSDesign, manufacturing, assembling, wiring, supply, installation, testingand commissioning of the following extensible cubicle type indoormounting, dead FRLSont, fully compartmentalised with hinged lockabledetachable FRLSont & back openable, dust and vermin proof, floormounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 415 volts 3 phase 4 wire 50cycle system, BMS Compiatable and to withstand a symmetrical faultlevel of below mentioned kA at 415 volts. Panels shall be fabricated ineasily transportable sections, length, height, depth etc. to match with sitecondition, complete in all respect as per direction of Engineer -in-charge.

1.1 Academic Block1.1.1 NSI-68 SDB-02/1 (Typical for SDB-02/2, SDB-02/3 and SDB-02/4) Sets 16.00

Incoming1 No. 100 A FP MCCB (35 KA) with E/F module & Core Balancing typeCT (CBCT) complete.Indication/metering1 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps1 set of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar

ELECTRICAL WORK

Page 60: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

1 set of 415V, 150A TPN aluminium busbars insulated with heatshrinkable coloured PVC sleeves. Outgoings4 Nos. 40A/ 63A FP MCB of 10 kA breaking capacity.2 Nos. 32 A DP MCB of 10 kA breaking capacity.

1.1.2 NSI-69 MDB-02 Sets 4.00INCOMER1 No. 400A FP MCCB (35 KA) with E/f module including 1 set of corebalancing CTs complete.1 No. 250A FP ATS (Auto-Transfer Switch)METERING & INDICATION2 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps2 sets of Digital Multifunction meter for Voltage, Current, KW, KWH KVAand Power Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBUS-BAR1 Sets of 400A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. 1 Sets of 500A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. OUTGOINGS1 No. 250A FP MCCB (35 KA) 14 Nos. 63A/ 100A FP MCCB (35 KA)2 No. 32A DP MCB (10 KA)

1.1.3 NSI-70 SDB UPS-02 Sets 4.00Incoming2 Nos. 63A FP MCCB (35 KA)Indication/metering2 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps2 sets of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar2 Sets of 100A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. BUS COUPLER:-1 No. 63A FP MCCB (10KA) with over-rated neutral.1 Set of Breaker ON-OFF-TRIP indication Lamps .Outgoings4 Nos. 40/63A DP MCB (10 KA)6 Nos. 32A DP MCB (10 KA)

1.1.4 NSI-71 SDB HVAC Sets 4.00Incoming1 Nos. 400A FP MCCB (35 KA)Indication/metering1 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps

Page 61: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

1 sets of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 400/5A CTs (400A/500V) ratingBusbar1 Sets of 500A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. Outgoings5 Nos. 125A FP MCCB

1.2 Admin Building1.2.1 NSI-72 MDB-01/1 (Typical for MDB-01/2) Sets 2.00

INCOMER1 No. 250A FP MCCB (35 KA) with E/f module & Core Balancing type CT(CBCT) complete.1 No. 160A FP ATS (Auto-Transfer Switch)METERING & INDICATION2 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps2 sets of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBUS-BAR1 Sets of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves

1 Sets of 300A TPN Aluminium Bus Bar with colour coded PVC Sleeves

OUTGOINGS1 No. 160A FP MCCB (35 KA)6 Nos. 100/63A FP MCCB (35 KA)13 Nos. 40/63A FP MCB (10 KA)1 Nos. 32A DP MCB (10 KA)

1.2.2 NSI-73 SDB UPS-01 Sets 1.00Incoming2 Nos. 100 A FP MCCB (35 KA)Indication/metering2 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps2 sets of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar2 Sets of 150A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. BUS COUPLER:-1 No. 100A FP MCCB (10KA) with over-rated neutral.1 Set of Breaker ON-OFF-TRIP indication Lamps .Outgoings4 Nos. 40/63A DP MCB (10 KA)4 Nos. 32A DP MCB (10 KA)

1.3 Workshop

Page 62: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

1.3.1 NSI-74 MDB-03 Sets 1.00Incoming1 No. 250 A FP MCCB (35 KA) with E/f module including 2 set of corebalancing CTs complete.Indication/metering1 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps1 set of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar1 Sets of 300A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. Outgoings9 No. 100A FP MCCB (35 KA)5 No. 40/63A FP MCB (10KA)

1.4 NSI-75 Lecture Hall1.4.1 MDB-05/1 Typical for MDB-05/2 Sets 2.00

Incoming1 No. 100 A FP MCCB (35 KA) with E/f module including 2 set of corebalancing CTs complete.Indication/metering1 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps1 set of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar1 Sets of 150A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. Outgoings2 No. 40/63A FP MCCB (35 KA)9 No. 40/63A FP MCB (10KA)2 No. 32A FP MCCB (10 KA)

1.5 NSI-76 Library1.5.1 MDB-09 Sets 1.00

Incoming1 No. 250 A FP MCCB (35 KA) with E/f module including 2 set of corebalancing CTs complete.Indication/metering1 Sets of `ON' , `OFF', `Trip' and R,Y,B phase indicating lamps1 set of Digital Multifunction meter for Voltage, Current, KW, KVA andPower Factor with selector switch. Each with 3nos. Of 2A SP MCB &3nos 250/5A CTs (250A/500V) ratingBusbar1 Sets of 300A TPN Aluminium Bus Bar with heat shrinkable colouredPVC sleeves. Outgoings8 No. 63A FP MCCB (35 KA)6 No. 40/63A FP MCB (10 KA)

Page 63: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

1 No. 32A FP MCB (10 KA)

1.6 ISOLATOR BOXDesign, supply, installation, testing & commissioning of following capacityIsolator Box for use on 3 phase 4 wire 415V, 50 Hz., AC supply with1.6mm thick sheet steel enclosure with Jinged & lockable/ padlockeddoor, duly powder coated including with MCCB Isolator complete etc. asrequired.

1.6.1 NSI-77 100A FP MCCB in Sheet Steel Enclosure Nos 2.001.6.2 NSI-78 63A FP MCB in Sheet Steel Enclosure Nos 9.00

TOTAL AMOUNT SUBHEAD-I

2 SUBHEAD-II : LT CABLE & TERMINATION2.1 LT CABLE (Supply)

Supply, Receiving & storing of the following sizes of 1.1 KV grade XLPE insulated Aluminium/ Copper conductor armoured, stranded, Power Cables in the existing Cable Trays / Pipes / laid underground/ surface etc., as required, as per technical specifications / details.

2.1.1 NSI-79 3.5C x 35 sq. mm Al. Ar. cable RM 80.002.1.2 NSI-80 3.5C x 25 sq. mm Al. Ar. cable RM 710.002.1.3 NSI-81 4C x 16 sq. mm Al. Ar. cable RM 630.002.1.4 NSI-82 4C x 10 sq. mm Al. Ar. cable RM 150.002.1.5 NSI-83 4C x 6 sq. mm Al. Ar. cable RM 355.002.1.6 NSI-84 4C x 25 Cu. Un Ar. Cable RM 150.002.1.7 NSI-85 4C x 16 Cu. Un Ar. Cable RM 640.00

2.2 Cable End TerminationSupply and making End termination with brass compression Gland andAl. lugs for the following size of PVC insulated and PVC shielded/ XLPEAluminium /Cu. conductor armoured / unarmoured Power cables / wiresof 1.1 KV grade as required.

2.2.1 NSI-86 4C x 6 sq. mm Al. Ar. cable Nos 24.002.2.2 NSI-87 4C x 25 Cu. Un Ar. Cable Nos 14.002.2.3 NSI-88 4C x 16 Cu. Un Ar. Cable Nos 66.00

TOTAL AMOUNT SUBHEAD-II

3 SUBHEAD-III : CABLE TRAY 3.1 Cable Trays Perforated Type

Supply and fixing of the following sizes of Perforated GI hot dippedgalvanized cable trays (stove enameled) including suspending fromceiling with M.S. angle supports, nut bolts, washers, fasteners etc. asrequired. (Measurement of angle iron and MS rod shall be included incable tray).

3.1.1 NSI-89 300 mm wide, 50 mm high,1.6mm thick RM 65.003.1.2 NSI-90 150 mm wide, 40 mm high,1.6mm thick RM 60.00

3.2 Cable Trays Ladder Type

Page 64: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

Supplying and fixing ladder type prefabricated hot dip galvanised G.I.cable tray complete with bend/tee joints, coupling plate and nuts, bolts,washers etc. with central rungs of size 15mmx30mmx2.0mm thick at250mm c/c.

3.2.1 NSI-91 600 mm ( side runner 20mmx50mmx2.0mm thick ) RM 55.003.2.2 NSI-92 900 mm ( side runner 20mmx50mmx2.0mm thick ) RM 45.00

TOTAL AMOUNT SUBHEAD -III

4 SUBHEAD-IV : DISTRIBUTION BOARD4.1 Supplying and fixing of following rating, 240/415 volts, "c" curve,

Miniature Circuit Breaker suitable for inductive load of following poles inthe existing MCB DB complete with connections, testing andcommsioning as required.

4.1.1 NSI-93 S/F FP MCB (63 AMPS) Nos 65.004.1.2 NSI-94 S/F FP MCB (40 AMPS) Nos 60.00

TOTAL AMOUNT SUBHEAD -IV

6 SUBHEAD-VI : POINT WIRING

6.1 Supplying and laying following pair, 0.6 mm PVC insulated copperconductor, PVC Sheathed armoured telephone cable, as per ITDspeccification S/WS-113C & S/WS-114, in the existing trench/ pipe/surface.

6.1.1 NSI-95 10 pair armoured Telephone wire RM 280.006.1.2 NSI-96 20 pair armoured Telephone wire RM 330.006.1.3 NSI-97 30 pair armoured Telephone wire RM 1800.006.1.4 NSI-98 50 pair armoured Telephone wire RM 120.00

6.2 Supplying, fixing, terminating tel. wire, testing & commissioning offollowing pair,Telephone Tag Block complete in all respect.

6.2.1 NSI-99 10 Pair Nos 7.006.2.2 NSI-100 20 Pair Nos 6.006.2.3 NSI-101 40 Pair Nos 6.006.2.4 NSI-102 50 Pair Nos 4.006.2.6 NSI-103 80 Pair Nos 16.006.2.7 NSI-104 100 Pair Nos 1.006.2.8 NSI-105 150 Pair Nos 4.006.2.9 NSI-106 160 Pair Nos 2.00

6.3 Data & Voice Information Outlets (for Institutional Buildings)6.3.1 NSI-107 Supply & Installation of CAT 5e information outlets complying fully or

exceeding with category 5e connecting hardware specifications for all paircombinations up to 100 MHz. (Yellow in colour For Voice) complete asrequired. Nos 420.00

Page 65: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

6.3.2 NSI-108 Supply & Installation of CAT 6 information outlets complying fully orexceeding with category 6 connecting hardware specifications for all paircombinations up to 250 MHz. Outlets shall use lead frame technology,non PCB pyramid type. (Blue in Colour for Data) complete as required. Nos 540.00

TOTAL AMOUNT SUBHEAD VI

7 SUBHEAD-VII : SUPPLY OF LIGHT FIXTURES7.1 Supplying, storing, and assembling the following fixtures complete with

electronic ballast / Dimmable electronic ballast with performer chock,BEE 4 star or better, fixing arrangement etc. as required.

7.1.1 NSI-109 Ceiling Suspended LED Fixture (4400 Lumens) Cat No: Philips StratusSP790P LED44S-5000 PSE ODSI or equivalent Nos 95.00

7.1.2 NSI-110 Surface Mounted LED Fixture (3000 Lumens) Cat No:Philips SerenoRC869B LED 30S-6500 PSE W30LI20 D8 GR or equivalent Nos 260.00

7.1.3 NSI-111 Surface Mounted LED Fixture (3400 Lumens) Cat No Philips CirrusSurface SM365C LED-34-5000 PSE-OD GR or equivalent Nos 18.00

7.1.4 NSI-112 Recessed Mounted LED Fixture (3300 Lumens) Cat No Philips CirrusRC 365/366B LED 33-5000 PSU OD GR/WH or equivalent Nos 100.00

7.1.5 NSI-113 Wall Mounted 1x36W Florucent Light (Cat No: Wipro WCF 51140 SGWor equivalent Nos 32.00

7.1.6 NSI-114 Surface/wall mounted 1x28W Florucent light. (Cat No. : Philips Aspire T528W or equivalent) Nos 85.00

7.1.7 NSI-115 Surface/wall mounted 1x28W Florucent light. (Cat No. : Philips Vector V2T5 28W or equivalent) Nos 317.00

7.1.8 NSI-116 Surface mounted 2x11W CFL light fitting (Cat No. : Philips FCS 518/211or equivalent) Nos 199.00

7.1.9 NSI-117 Surface mounted 2x18W CFL light fitting (Cat No. : Philips FCS 518/218or equivalent) Nos 1395.00

7.1.10 NSI-118 Surface wall mounted 2x28W Florucent light. (Cat No. : Philips TCS350 2xTL5-28W EBE C5 or equivalent) Nos 2330.00

7.1.11 NSI-119 Surface mounted 1x11 w CFL Mirror light (Cat No. : Wipro WRP 2111or Equivalent) Nos 158.00

7.1.12 NSI-120 Surface mounted 1x11 w Toilet light (Cat No. : Bajaj BJLF3 11W RF orEquivalent) Nos 296.00

7.1.13 NSI-121 Surface mounted 2x36W CFL light fitting (Cat No. : Wipro WVP 44236SWG or equivalent) Nos 95.00

Page 66: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

7.1.14 NSI-122 Recessed mounted 2x36W CFL light fitting (Cat No. : Philips FBS 440 or Equivalent) Nos 578.00

7.1.15 NSI-123 Ceiling Suspended 1x 150W CDM-ET lamp (Philips Cat. No. HPK225 1x CDM-ET 150W PR or equivalent) Nos 100.00

7.1.16 NSI-124 Surface mounted 1x9W bulk head light (Cat No. : Philips FXC 101/109or equivalent) Nos 203.00

7.1.17 NSI-125 1 x 70 W Street light luminiare with pressure die cast aluminium housinghaving POT optics, including providing of 70W SON lamp complete(Philips Cat. No. SGP301 GLA SON 70W(I) or equivalent) Nos 4.00

7.1.19 NSI-126 Self illuminated LED Exit / Fire Exit Signs mounted on ceiling/wall asper site conditions including providing of maintenance free batteries for60 minutes back-up and battery charger. (Cat No. : Bajaj 220208/9 orequivalent) Nos 12.00

7.1.20 NSI-127 Supplying, storing, and assembling of the Ceiling Fan 1200mm (5 StarRating) Nos 1724.00

7.1.21 NSI-128 Supplying, storing, and assembling of the Ceiling Fan 1400mm (ISIMarked) Nos 40.00

7.1.23 NSI-129 Supplying, storing, and assembling of the Exhaust Fan 300mm includingmaking the hole to suit the size of fan, making good the damage,connection, testing, commissioning etc. as required. (ISI Marked)

Nos 80.00

7.1.24 NSI-130 Supplying, storing, and assembling of the Exhaust Fan 450mm includingmaking the hole to suit the size of fan, making good the damage,connection, testing, commissioning etc. as required. (ISI Marked)

Nos 44.00

7.2 Installation, Testing & commissioning of pre-wired fitting as describedabove with fixing arrangement etc. as required.

7.2.1 NSI-131 Installation, Testing & commissioning of recessed type, pre-wired,fluorescent fitting/ compact flourescent fitting of all types, complete withall accessories and tube etc. on False ceiling, including connection with1.5 sq. mm FRLS PVC insulated, copper conductor. single core cableand earthing etc. as required. Each 688.00

TOTAL AMOUNT SUBHEAD-VII

9 SUBHEAD-IX : EARTHING

Page 67: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

9.1 Supplying, Receiving, unloading, storing laying, effecting properconnections, testing and commissioning of following sizes of 1.1 KVXLPE insulated single Copper conductor overall PVC SheathedUnarmoured Cable on existing cable trays/ Pipes trenches etc. includingproviding the MS supports and clamps for fixing to supports in anapproved manner complete as required and as per specifications. ( forearthing of UPS, EPABX, Network rack etc.)

9.1.1 NSI-132 1C x 50 sqmm XLPE Insualted copper conductor Unarmoured cable RM 400.009.1.2 NSI-133 1C x 35 sqmm XLPE Insualted copper conductor Unarmoured cable RM 80.009.1.3 NSI-134 1C x 16 sqmm XLPE Insualted copper conductor Unarmoured cable RM 260.00

9.2 NSI-135 Supply, fabrication, erection, testing & commissioning of 2 nos. 300mmlong, 32mm x 6mm thick Cu. Bus-bar on insulated PVC stud/ support in450mm(L) x 250mm(W) x 200mm(D) size of 16SWG, powder coated MSbox with Hinged & locakable door for dedicated earthing, complete witheffecting proper connection of exisiting STRIP/wires/cables with Cu.thimbles Set 26.00

TOTAL AMOUNT SUBHEAD IX

10 SUBHEAD-X : POWER BACKUP & LIGHTING CONTROL SYSTEM10.1 UNINTERRUPTED POWER SUPPLY (UPS)

10.1.1 NSI-136 Supply, installation, testing and commissioning of 20 KVA UPS along withlead acid batteries, 6 Pulse rectifier + Filter + SNMP & IGBT Inverterbased,complete as required. 20 KVA 3 phase input (415 V + 15% / -25%), three phase output (415 V + 0.05%) with 15 minutes batterybackup of each UPS complete with battery rack and connecting wires.

Sets 9.00

10.1.2 NSI-137 Supply, installation, testing and commissioning of 10 KVA UPS along withlead acid batteries, 6 Pulse rectifier + Filter + SNMP & IGBT Inverterbased,complete as required. 10 KVA 3 phase input (415 V + 15% / -25%), three phase output (415 V + 0.05%) with 15 minutes batterybackup of each UPS complete with battery rack and connecting wires.

Sets 2.00

10.2 INVERTER FOR EMERGENCY LIGHTING10.2.1 NSI-138 Supply, installation, testing and commissioning of 2.5 KVA Inverter along

with lead acid batteries giving a back up along with powder coatedcabinet for housing the inverter and batteries, complete as required andas per specifications, complete with 90 minutes battery backup

Sets 4.00

10.2.2 NSI-139 Supply, installation, testing and commissioning of 1.5 KVA Inverter alongwith lead acid batteries giving a back up along with powder coatedcabinet for housing the inverter and batteries, complete as required andas per specifications, complete with 90 minures battery backup

Sets 3.00

TOTAL AMOUNT SUBHEAD-VII11 SUBHEAD-XI : Fire Alarm

Page 68: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

INTELLIGENT FIRE DETECTION SYSTEM & ALARM SYSTEMSupply, installation, testing and commissioning of following as perspecifications :

11.1 NSI-140 Fire Alarm PanelProviding, installing, connecting, testing and commissioning of microprocessor based Logic driven Network (with Network card as required) onPeer to Peer Analogue Addessable of following no. of Loop (each loopaccessing not less than 125 addressable detectors) Fire Alarm ControlPanel. The Panel shall be able to give pin point location of all Fire/ Faultconditions of addressable units via the address codes for each unit. ThePanel shall also be able to automatically switch off all Control Switcheswhen ever any Alarm is triggered. The Panel shall be coupled to the PASystem and have sealed maintenance free batteries of required capacityof 24 volts capable of running for a minimum of 24 hours with batterycharger, rectifier, Loop cards, Keypad operation, LCD unit to indicate Fire/Fault Signal of individual unit, in built / external printer to log all incomingdata etc. complete in all respects. The Panel shall also have Logichardware and software built into it for initiating specific AHU tripping, timedelay operation of hooter, subsequent operation of speakers. Panel shallhave provide data output on Modbus for Building management System

11.1.1 3 Loop Panel Nos 1.0011.1.2 2 Loop Panel Nos 4.0011.1.3 1 Loop Panel Nos 1.00

11.2 NSI-141 Network repeator PanelProviding, installing, testing and commissioning of Networked RepeaterPanel along with network card as required for Fire Alarm System withpiezo sounder, LCD alpha numeric character display with accept / resetbuttons for alarm address of any sensor / field device. The RepeaterPanel shall only provide field device address with number.

Nos 6.00

11.3 NSI-142 Multisensor DetectorSupplying, Installation, testing and Commissioning of Intelligent andelectronically addressable multi sensor detector with microprocessor inhead and including the base with LED etc as per specification.

Nos 1245.00

11.4 NSI-143 Heat DetectorSupplying, Installation, testing and Commissioning of Intelligent andelectronically addressable high sensitivity four dimensional / laserdetector with microprocessor in head and including the base with LED etcas per specification for server rooms Nos 4.00

11.5 NSI-144 Response IndicatorSupplying, Installation, testing and Commissioning of Response Indicatorwith twin transparent LED that shall glow red in case of fire Nos 445.00

11.6 NSI-145 Fault Isolator Module

Page 69: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

Supplying, Installation, testing and Commissioning of Fault isolatormodule for isolating shorted, dewired and loose circuits between twosuccessive fault with automatic resetting arrangement. Nos 48.00

11.7 NSI-146 Control ModuleSupplying, Installation, testing and Commissioning of Addressable controlmodules for controlling AHU’s, and magnetic fire door holders. Elevatorrecall, fire damper, pressurization fan, speakers, strobes etc.

Nos 8.00

11.8 NSI-147 Monitor ModuleSupplying, Installation, testing and Commissioning of Addressablemonitoring module to connect NO/NC contacts such as pressure switch,flow switches, fire pump contacts (provided by Fire fighting contractor).However testing and commissioning shall be included in the fire detectionand alarm system contractor scope. Nos 48.00

11.9 NSI-148 Manual Call BoxSupplying, Installation, testing and Commissioning of AddressableManual Call Box made of polycarbonate with plastic break glass front.MCB shall be recessed in wall . The MCB shall have "IN CASE OF FIREBREAK GLASS" imprinted on the facia. Nos 48.00

11.10 NSI-149 Hooter with StrobeSupplying, Installation, testing and Commissioning of Piezo electronicHooters/ Sounders of 90 dBA sound level minimum 10 feet away from thedevice with strobe including Control Module complete as required,including ceiling/ wall mounting arrangements . Nos 81.00

11.11 NSI-150 Telephone Talk Back JackSupplying, Installation, testing and Commissioning of Addressable TwoWay communication Fire Fighters telephone Jack Nos 52.00

11.12 NSI-151 Supplying, Installation, testing and Commissioning of of Fire fightersHandset Nos 6.00

11.13 NSI-152 TWO Way Fire Fighters (DVC)Supply, Installation, Testing & commissioning of integrated 8 channelDigital Voice evacuationn & Two Way Communication Fire Fighterexpandable upto 12 channels system capable to supervision of all circuitswith accessories etc. as required for complete system. The equipmentshall be of same make as Panel for Fire Alarm System.

Nos 6.00

11.14 NSI-153 Audio Coupling TransformerSupply, Installation, Testing & commissioning of Audio CouplingTransformer to integrate DVC with analog amplifiers of PA System alongwith all accessories, hardwares as required.. Nos 6.00

11.15 NSI-154 Software System

Page 70: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

Supplying, Installation, testing and Commissioning of Fire Alarm PCStation consisting of Pentium core i3 processor, 21" colour LCD TFTmonitor, 1024 MB RAM, 120 GB Hard Disk, DVD Drive, USB Port,Ethernet port, mouse, Windows XP/7 based Software, Graphic (GUI)software including copy in CD ROM complete as required. PC WorkStation shall include complete Fire Alarm Graphics Software includingfloor plans with location of detectors and other devices. All Floors shall beavailable as drawing files with location of detectors and devices completewith Loop number and other details as available on the Software. TheSoftware shall be customised to the Building and Fire Alarm layout of thebuilding with location of detectors marked on floor drawings complete withdetector address, detector condition etc. The PC and software shall allowfor programming / re programming of detector addresses, addition ordeletion of detectors with address change, condition of detectors, eventlogs for 1000 events complete. The Softwares shall be supllied completewith registered CD unit complete and site training. Set 1.00

11.16 NSI-155 Fire Survival Cable for Signal. Supplying, Installation, testing and Commissioning of 2C x 1.5 sqmm,

Class 2 Annealed Copper conductor Unarmoured Cable, Mica Glass (fireresistant) tape with low smoke zero halogen (LSZH) cross- linkable flameretardant insulation. RM 27160.00

11.17 Network WireSupply, Receiving & storing of the following sizes of 1.1 KV grade XLPE insulated Aluminium/ Copper conductor armoured, stranded, Power Cables in the existing Cable Trays / Pipes / laid underground/ surface etc., as required, as per technical specifications / details.

11.17.1 NSI-156 Supplying of 2C x 2.5 Sq. mm. Cooper Armoured Cable RM 1320.00

TOTAL AMOUNT SUBHEAD XII

12 SUBHEAD-XII : PUBLIC ADDRESS SYSTEM12.1 NSI-157 Supply installation testing and commissioning of flush mount ceiling

speakers Philips cat No.LBD0606 or equivalent (6 Watts Read Power)including linematching transformer ceiling recessed mounting in falseceiling with clamp complete as required. Set 8.00

12.2 NSI-158 Supply installation testing and commissioning of Wall mount coloumn/Box type speaker Philips cat No.LBD 8352 or equivalent (6 Watts ReadPower) including linematching transformer Wall Mounted with clampcomplete as required. Set 1210.00

12.3 NSI-159 Supplying, Installation, testing and Commissioning of 1 x 120W PAAmplifier complete with Rack of suitable size and channel mixer, 5 bandgraffic equalizer complete with internal wiring etc. as required Set 4.00

12.4 NSI-160 Supplying, Installation, testing and Commissioning of 1 x 240W PAAmplifier complete with Rack of suitable size and channel mixer, 5 bandgraffic equalizer complete with internal wiring etc. as required Set 1.00

Page 71: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

12.5 NSI-161 Supplying, Installation, testing and Commissioning of 1 x 480W PAAmplifier complete with Rack of suitable size and channel mixer, 5 bandgraffic equalizer complete with internal wiring etc. as required Set 17.00

12.6 NSI-162 Supply, installation, testing & Commissioning of Gooseneck cardiodmicrophone for zonewise paging, 15keys extendable upto 105 havingEmergency Broadcast, Volume Control, RJ45 connector, with powersupply etc. complete as required. Nos 6.00

12.7 NSI-163 Supplying, installing, testing and commissioning of PA System OperatorConsole complete with 1 no CD Player deck MP3 format, Change overPanel for connection to the Fire Alarm Panel, a Mains Panel, a standbybattery of required capacity and a Monitor Panel all pre wired and rackmounted complete in all respects & as per specifications. PA Systemshall be coupled to the Fire Alarm System.

Nos 6.00

12.8 NSI-164 Supply, installation, testing & Commissioning of Flush Mounted ModularType Volume Controller in MS Box with Plate, Knob, Panel etc. completewith interconnections as required. Nos 360.00

12.9 NSI-165 Supply, installation, testing & Commissioning of 0.75 Sq. mm twin twistedunseathed speaker wire in existing conduit. Nos 28400.00

TOTAL AMOUNT SUBHEAD XII

13 SUBHEAD XIII : CCTV SYSTEM13.1 Supply, installation, testing and commissioning of 25X optical and 10X

digital Pan/Tilt/Zoom cameras including integrated Housing , Connectors,Lens, Camera Mounts, Power Supply with battery backup of 15 minutesand all Ancillary Equipment & all accessories including Remote RecieverUnit and Pan Tilt Unit (including driver cables) as per specifications

13.1.1 NSI-166 With Wall mounted indoor housing Nos 1.0013.1.2 NSI-167 With Wall mounted outdoor housing with sunshield, heater and blower Nos 5.00

13.2 NSI-168 Supply, installation, testing and commissioning of keyboard/Joystick forcontrolling PTZ cameras

Nos 6.00

13.3 NSI-169 Supply, installation, testing and commissioning of 1/3 interline transferCCD minidome Fixed indoor dome type with 2.8~10 mm lens,0.1 lux530TVL, BLC, WDR, D\N camera Mounts, power supply with batterybackup of 15 minutes and all Ancillary Equipment & all accessories asper specifications. Nos 19.00

Page 72: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

13.4 NSI-170 Supply, installation, testing and commissioning of DVR with built inmultiplexer for 9 input real time, live monitoring and playback, 400 fps fullframe recording with 2 video outputs and intelligent power failurerecovery, The DVR should provide with remote monitoring software withHard Disk facility recording(30 Days Backups) as per specifications.

Nos 6.00

13.5 NSI-171 Supplying, Installation, testing and Commissioning of 21” CCTV colourTFT Monitor including all accessories Nos 6.00

TOTAL AMOUNT SUBHEAD XIII

14 SUBHEAD XIV : SAFETY EQUIPMENTS14.1 NSI-172 Supplying and fixing of non-skid rubber mat 12mm thick and 900mm

width as required including cutting to required lengths of approved makewith Test Certificates suitable for 1100 Volt. Mtrs. 300.00

14.2 NSI-173 Supplying and fixing of shock treatment chart written in English and Hindiduly framed in as required. Each 10.00

14.3 NSI-174 Supplying and fixing of first aid box as approved complete with standardkit as prescribed by Indian Red Cross. Each 9.00

14.4 NSI-175 Supply of Hand gloves made out of rubber suitable for 1100 volt gradePairs 10.00

14.5 NSI-176 Supplying and fixing of a set of four nos. of fire bucket painted red andduly filled with sand conforming to IS: 2546-1974 complete with MS standsuitable for supporting four buckets (Pedestal type) Each 10.00

14.6 NSI-177 Supplying and fixing of 4.5 kgs. Capacity carbon dioxide type fireextinguisher of ISI approved make with wall mounting bracket asrequired. Each 10.00

14.7 NSI-178 Supplying and fixing of 4 kgs. Capacity ABC dry powder type fireextinguisher of ISI approved make with wall mounting bracket asrequired. Each 10.00

TOTAL AMOUNT SUBHEAD XIV

15 SUBHEAD XV : DEHUMIDIFICATION

Page 73: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

15.1 Supply, installation, testing & commissioning of desiccant typedehumidifier system complete with Process Blower, Reactivation Blower,Post Cooling Coil, Dehumidifier Section, electrical control panel &necessary insulation, dampers, controls and condensate connection, DXtype outdoor unit which shall be hooked with dehumidifier etc complete inall respects and as per specifications. Zero leak / very low leakage,Aluminium supply air, return air, fresh air & exhaust air dampers. Thedesiccant honeycomb rotor media shall be adsorbent, non toxic, nonflammable, fully water washable, having desiccant with nett organics lessthan 2%. The unit shall be fully welded both internal and external providedwith double skin insulated panels within the industrial quality welded SSframe workNSI-179 Ground & Second Floor, each 2500 CFM ( 12 TR ) No. 8.00

NSI-180 First & Third Floor, each 3000 CFM ( 14 TR ) No. 8.00

15.2 AIR DISTRIBUTION

1 Supply, installation and testing of Factory fabricated GSS ducts as perSMACNA of following thickness including neccesary supports, adjustabledampers, vanes, etc., complete as per specifications.

1.1 NSI-181 26 gauge galvanised sheet steel Sqm. 1660.00

2 NSI-182 Supply, installation, testing and balancing of powder coated ExtrudedAluminium Supply air Grilles with volume control dampers as perspecifications as required.

Sqm. 8.00

3 THERMAL INSULATION1 Supply, installation testing and commissioning of acoustic insulation.

Material shall be open cell nitrile rubber ( with self adhesive ) based- fibreglass free with 140-180 Kg/m3 density and all accessories as perspecification.

1.1 NSI-183 15 mm thick acoustic lining. Sq.m. 100.00

2 Supply, installation and testing of External Thermal insulation on ductscovered with closed cell crosslinked polyethylene foam having density 25-30 with self adhesive as per the approved specifications. The above shallbe inclusive of self adhesive, tapes, UV protective coating over exposedducts as per the specifications as required.

2.1 NSI-184 12 mm thick insulation for supply & return air ducts. Sq.m. 1820.00

TOTAL CARRIED TO SUMMARY

SUBHEAD - I - LIFT

LIFTS WORK

Page 74: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

1 NSI-185 Supply, installation, testing & commissioning of 13 passanger (884 Kg)lifts having contract speed of 1.00 MPS serving different floors in the liftshaft. Flooring of PVC tiles 3 mm thick, automatic electric leveling device,automatic rescue device. Lift will be complete with combined luminoushall button with seven segment digital hall position indicator at all floor,car operating panel with luminous buttons, seven segment digital carposition indicator combined with direction arrows, overload warningindicator, battery operated alarm bell and emergency light, fireman'sswitch at main lobby enclosed complete as per CPWD GeneralSpecification for electrical works and detail specification enclosed asunder:1) DESIGN OF LIFTS - PASSENGER TYPE2) CAPACITY - 13 PASSENGER / 884 KG3) SPEED - 1.00 m/s4) DRIVE - GEARLESS MACHINE A.C. VVVF DRIVE5) MACHINE ROOM LOCATION ON TERRACE6)TRAVEL - 7.20 Mtr. (Approximate)7) FLOORS - 0, 1, 2 Floor8) NO. OF STOPS/OPENINGS - 3 Stops9) REQUIRED WELL SIZE - As per IS specification10) POWER SUPPLY - 415 V - 3 Phase 50 HZ AC11) AUXILIARY - Single Phase 220 V AC12) CAR SIZE - As per IS specification13) PIT DEPTH - 1600 MM14) CAR ENCLOSUREa) CAR CEILING - SS HAIRLINE FINISHb) CAR PANELS - SS HAIRLINE FINISHc) ILLUMINATION - FLUROSCENT LIGHTd) CAR FLOORING - 20 MM RECESS15) NO. OF ENTRANCE - ONE LOCATION FRONT16) CAR ENTRANCE - AUTOMATIC COPD DOORS IN SS HAIRLINEFINISH17) DOOR SAFETY - FULL HEIGHT INFRARED LIGHT CURTAIN18) LANDING ENTRANCE - AUTOMATIC COPD DOORS IN SSHAIRLINE FINISH19) CONTROL - SIMPLEX SELECTIVE COLLECTIVE Set 2.0020) Complete in all resprects as per IS and local statuary authority

2 NSI-186 Supply, installation, testing & commissioning of 13 passanger (884 Kg)lifts having contract speed of 1.00 MPS serving different floors in the liftshaft. Flooring of PVC tiles 3 mm thick, automatic electric leveling device,automatic rescue device. Lift will be complete with combined luminoushall button with seven segment digital hall position indicator at all floor,car operating panel with luminous buttons, seven segment digital carposition indicator combined with direction arrows, overload warningindicator, battery operated alarm bell and emergency light, fireman'sswitch at main lobby enclosed complete as per CPWD GeneralSpecification for electrical works and detail specification enclosed asunder:1) DESIGN OF LIFTS - PASSENGER TYPE2) CAPACITY - 13 PASSENGER / 884 KG

Page 75: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

3) SPEED - 1.00 m/s4) DRIVE - GEARLESS MACHINE A.C. VVVF DRIVE5) MACHINE ROOM LOCATION TERRACE6)TRAVEL - 10.80 Mtr. (Approximate)7) FLOORS - 0, 1, 2, 3 Floor8) NO. OF STOPS/OPENINGS - 4 Stops9) REQUIRED WELL SIZE - As per IS specification10) POWER SUPPLY - 415 V - 3 Phase 50 HZ AC11) AUXILIARY - Single Phase 220 V AC12) CAR SIZE - As per IS specification13) PIT DEPTH - 1600 MM14) CAR ENCLOSUREa) CAR CEILING - SS HAIRLINE FINISHb) CAR PANELS - SS HAIRLINE FINISHc) ILLUMINATION - FLUROSCENT LIGHTd) CAR FLOORING - 20 MM RECESS15) NO. OF ENTRANCE - ONE LOCATION FRONT16) CAR ENTRANCE - AUTOMATIC COPD DOORS IN SS HAIRLINEFINISH17) DOOR SAFETY - FULL HEIGHT INFRARED LIGHT CURTAIN18) LANDING ENTRANCE - AUTOMATIC COPD DOORS IN SSHAIRLINE FINISH19) CONTROL - SIMPLEX SELECTIVE COLLECTIVE Set 8.0020) Complete in all resprects as per IS and local statuary authority

3 NSI-187 Supply, installation, testing & commissioning of 15 passanger( 1020 Kg)lifts having contract speed of 1.00 MPS serving different floors in the liftshaft. Flooring of PVC tiles 3 mm thick, automatic electric leveling device,automatic rescue device. Lift will be complete with combined luminoushall button with seven segment digital hall position indicator at all floor,car operating panel with luminous buttons, seven segment digital carposition indicator combined with direction arrows, overload warningindicator, battery operated alarm bell and emergency light, fireman'sswitch at main lobby enclosed complete as per CPWD GeneralSpecification for electrical works and detail specification enclosed asunder:1) DESIGN OF LIFTS - PASSENGER/HOSPITAL TYPE2) CAPACITY - 15 PASSENGER / 1020 KG3) SPEED - 1.00 m/s4) DRIVE - GEARLESS MACHINE A.C. VVVF DRIVE5) MACHINE ROOM LOCATION TERRACE6)TRAVEL - 10.80 Mtr. (Approximate)7) FLOORS - 0, 1, 2, 3 Floor8) NO. OF STOPS - 4 Stops9) REQUIRED WELL SIZE - As per IS specification10) POWER SUPPLY - 415 V - 3 Phase 50 HZ AC11) AUXILIARY - Single Phase 220 V AC12) CAR SIZE - As per IS specification13) PIT DEPTH - 1600 MM

Page 76: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

14) CAR ENCLOSUREa) CAR CEILING - SS HAIRLINE FINISHb) CAR PANELS - SS HAIRLINE FINISHc) ILLUMINATION - FLUROSCENT LIGHTd) CAR FLOORING - 20 MM RECESS15) NO. OF ENTRANCE - ONE LOCATION FRONT16) CAR ENTRANCE - AUTOMATIC COPD DOORS IN SS HAIRLINEFINISH17) DOOR SAFETY - FULL HEIGHT INFRARED LIGHT CURTAIN18) LANDING ENTRANCE - AUTOMATIC COPD DOORS IN SSHAIRLINE FINISH19) CONTROL - SIMPLEX SELECTIVE COLLECTIVE Set 2.0020) Complete in all resprects as per IS and local statuary authority

4 NSI-188 Supply, installation, testing & commissioning of 10 passanger( 680 Kg)lifts having contract speed of 1.00 MPS serving different floors in the liftshaft.Flooring of PVC tiles 3 mm thick, automatic electric leveling device,automatic rescue device. Lift will be complete with combined luminoushall button with seven segment digital hall position indicator at all floor,car operating panel with luminous buttons, seven segment digital carposition indicator combined with direction arrows, overload warningindicator, battery operated alarm bell and emergency light, fireman'sswitch at main lobby enclosed complete as per CPWD GeneralSpecification for electrical works and detail specification enclosed asunder:1) DESIGN OF LIFTS - PASSENGER TYPE2) CAPACITY - 10 PASSENGER / 680 KG3) SPEED - 1.00 m/s4) DRIVE - GEARLESS MACHINE A.C. VVVF DRIVE5) MACHINE ROOM LOCATION TERRACE6)TRAVEL - 7.20 Mtr. (Approximate)7) FLOORS - 0, 1, 2, Floor8) NO. OF STOPS -3 Stops9) REQUIRED WELL SIZE - As per IS specification10) POWER SUPPLY - 415 V - 3 Phase 50 HZ AC11) AUXILIARY - Single Phase 220 V AC12) CAR SIZE - As per IS specification13) PIT DEPTH - 1600 MM14) CAR ENCLOSUREa) CAR CEILING - SS HAIRLINE FINISHb) CAR PANELS - SS HAIRLINE FINISHc) ILLUMINATION - FLUROSCENT LIGHTd) CAR FLOORING - 20 MM RECESS15) NO. OF ENTRANCE - ONE LOCATION FRONT16) CAR ENTRANCE - AUTOMATIC COPD DOORS IN SS HAIRLINEFINISH17) DOOR SAFETY - FULL HEIGHT INFRARED LIGHT CURTAIN18) LANDING ENTRANCE - AUTOMATIC COPD DOORS IN SSHAIRLINE FINISH19) CONTROL - SIMPLEX SELECTIVE COLLECTIVE Set 4.00

Page 77: BILL OF QUANTITY - · PDF filec fire fighting works 1 piping, hydrant and accessories system ... 11 fire alarm 12 public address system 13 cctv system 14 safety equipments 15 dehumidification

In figure (Rs.) In Words (Rs.)S.No. DSR

2013 Description of Items QuantityUnit Quoted Rate Amount

20) Complete in all resprects as per IS and local statuary authority

TOTAL SUBHEAD - I