2
enable easy adaption to the different electrical requirements. Due to the constant current regulation the output is short- circuit proof, an automatical restart takes place after short- circuit and over temperature. The load limitation takes place automatically. Soft - Start after switching-on, this will protect connected electronic control systems. Primary voltages are optionally two AC voltages: 230 V / one phase or 400 V / two phase. Standart operation mode - charging unit On charging operation with IU - characteristic at first - in case of discharged battery - a constant current (I-characteristic) of 5 - 10 - 15 - 20 - 35 A, according to unit type, flows. Prior to attaining the adjusted final charging voltage the current falls. Simultaneously the voltage rises up to the final charging voltage (U-characteristic) and the current continues falling down until the value, required for trickle charging and for the supply of the connected consumers is attained.the nominal current is never exceeded due to the regulated current limitation. The factory pre-setting of the charging voltage lies below the permissible voltage at begin of gassing. Even in cases of short-circuit like load events (e.g. connecting a starter motor) the unit must not be disconnected, because the nominal current is never exceeded due to the regulated current limitation. ! Leadacid - or Ni/Cd batteries ! IU-W - characteristic according to DIN 41773 ! Charging currents 10A ! Boost chargeShort-circuit proof ! Supply voltage 230V AC oder 400V AC ! Soft-start after switching-on ! Transformer according VDE 0551 Application The battery charging and power supply units of the product line BGL.... are to be applied as IU-W - chargers according to DIN 41773 and as power supply units. On charging operation the units can be used both for lead-acid as well as for Ni/Cd batteries. The basic load of consumers connected in parallel to the battery can be supplied, whereby the remaining current up till the unit´s nominal current serves for charging or trickle charging of the battery. Design The units are delivered as compact modules (degree of protection IP 00) for fixation on a mounting plate. The units are equipped with mains transformer, thyristor control, smoothing device and control circuitry. Further advantages are the desirable mounting position, little need of space and little loss of heat. The potentiometers BATTERYCHARGER BGL eltroma - technik ! Komponenten zum Messen ! Steuern ! Regeln I/U Characteristic 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 13 Time in h 22 23 24 25 26 27 28 29 Current Batt.-V.

Transcript of BGL - Eltromaeltroma.de/katalog/020-Batterieladegeraete/010-en-BGL.pdf · et eltroma - technik gmbh...

Page 1: BGL - Eltromaeltroma.de/katalog/020-Batterieladegeraete/010-en-BGL.pdf · et eltroma - technik gmbh ! Schnackenburgallee 112 ! 22525 Hamburg Tel.: +49 (0) 40 / 5450 71 ! Fax: +49

enable easy adaption to the different electrical requirements.Due to the constant current regulation the output is short-circuit proof, an automatical restart takes place after short-circuit and over temperature. The load limitation takes placeautomatically.

Soft - Start after switching-on, this will protectconnected electronic control systems.

Primary voltages are optionally two AC voltages: 230 V /one phase or 400 V / two phase.

Standart operation mode - charging unit

On charging operation with IU - characteristic at first - incase of discharged battery - a constant current(I-characteristic) of 5 - 10 - 15 - 20 - 35 A, according to unittype, flows.

Prior to attaining the adjusted final charging voltage thecurrent falls. Simultaneously the voltage rises up to the finalcharging voltage (U-characteristic) and the currentcontinues falling down until the value, required for tricklecharging and for the supply of the connected consumers isattained.the nominal current is never exceeded due to theregulated current limitation.

The factory pre-setting of the charging voltage lies belowthe permissible voltage at begin of gassing. Even in casesof short-circuit like load events (e.g. connecting a startermotor) the unit must not be disconnected, because thenominal current is never exceeded due to the regulatedcurrent limitation.

! Leadacid - or Ni/Cd batteries

! IU-W - characteristic according to DIN 41773

! Charging currents 10A

! Boost chargeShort-circuit proof

! Supply voltage 230V AC oder 400V AC

! Soft-start after switching-on

! Transformer according VDE 0551

Application

The battery charging and power supply units of the productline BGL.... are to be applied as IU-W - chargers accordingto DIN 41773 and as power supply units. On chargingoperation the units can be used both for lead-acid as wellas for Ni/Cd batteries. The basic load of consumersconnected in parallel to the battery can be supplied,whereby the remaining current up till the unit´s nominalcurrent serves for charging or trickle charging of thebattery.

Design

The units are delivered as compact modules(degree of protection IP 00) for fixation on amounting plate.The units are equipped with mains transformer,thyristor control, smoothing device and controlcircuitry.

Further advantages are the desirable mounting position, littleneed of space and little loss of heat. The potentiometers

BATTERYCHARGERBGL

eltroma - technik ! Komponenten zum Messen ! Steuern ! Regeln

I/U Characteristic

2468

10121416

0 2 4 6 8 10 12 13Time in h

2223242526272829

Current Batt.-V.

Page 2: BGL - Eltromaeltroma.de/katalog/020-Batterieladegeraete/010-en-BGL.pdf · et eltroma - technik gmbh ! Schnackenburgallee 112 ! 22525 Hamburg Tel.: +49 (0) 40 / 5450 71 ! Fax: +49

et eltroma - technik gmbh ! Schnackenburgallee 112 ! 22525 HamburgTel.: +49 (0) 40 / 5450 71 ! Fax: +49 (0) 40 / 540 4089 ! e-mail: [email protected] ! website: www.eltroma.de

BATTERYCHARGERBGL

DESIGNATION / type BGL 0524 BGL 1024 BGL 1524 BGL 2024 BGL 3524

nominal current5A 10A 15A 20A 35A

leistung trafo 210VA 400VA 500VA 610VA 1200VAweight

4,6kg 5,6KG 7,5KG 13,5KG 21,0KG

supply voltage 230V AC or 400V AC (±20%)mains frequency 50/60 Hzload characteristic IU - characterisitic according to DIN 41773

W - characterisitic on final charging range

output voltage 12V to 33V dc, Soft-start at switching onduty cycle 100% EDefficiency rate ca. 90 %

ripple without battery about +- 2v on ohmic load on 50 % nom. current

overload regulated load limitation, sustained short- circuit proof, selfstarting after short-circuit and overtemperatre

ambient temperature -20°C bis +75°Cstorage temperature -40°C bis +90°Crel. humidity 95%Protection IP 00Maintance: no maintance

Terminal: 1,5 - 4mm2

Terminals boost-charging 0,75 - 2,5mm2

Mounting no specificCE conform

Fuses

Typ F1400/230V F2 F3

BGL 0524 2A / 4A 6A Siehe Text

BGL 1024 4A / 6A 16A Siehe Text

BGL 1524 4A / 6A 20A Siehe Text

BGL 2024 10A / 16A 25A Siehe Text

BGL 3524 16A / 20A 40A Siehe Text

F1 = Characteristic DF3 = as consumer

Typ X B Y H Z (Tiefe)

drilling

BGL 0524 135 90 150 121 120

BGL 1024 144 90 159 121 120

BGL 1524 164 90 179 121 120

BGL 2024 190 122 210 147 150

BGL 3524 270 138 290 165 170

All dimensions in mm