besser block retaining wall

7
BESSER® Brick and Block Product Guide AUSTRALIAN PAVING CENTRE

Transcript of besser block retaining wall

Page 1: besser block retaining wall

BESSER® Brick and BlockProduct Guide

AUSTRALIAN PAVING CENTRE

Page 2: besser block retaining wall

PriceProducts DescriptionSize (mm)l x h x w

Unitweight

(kg)

Render Brick (Solid)

Qty. perpallet

230 x 76 x 110 3.9450

Code

D11.076

Unit perm2

50

29090

90

Modular Brick (Solid) 290 x 90 x 90 4.8340D11.083 33

Quick Brick (Vertically Cored) 230 x 162 x 110 6.2270DV11.162 25

Brick

Full Length Hollow 390 x 190 x 90 11.2158D1001.1 12.5

29090

190

3/4 Length Hollow 290 x 190 x 90 8.2213D1002.1

19090

190

1/2 Length Hollow 190 x 190 x 90 5.4323D1003.1

90 90

190

1/4 Length Hollow 90 x 190 x 90 2.9645D1004.1

39090

90

Full Length 1/2 HeightHollow Universal 390 x 90 x 90 5.0315D1071.1

Full Length SolidUniversal 390 x 190 x 90 14.4110D1031.1 12.5

Full Length 1/2 HeightSolid Universal 390 x 90 x 90 6.4252D1083.1 25

Split Capping Unit 390 x 40 x 90 3.2600D10117.1

Sandhurst Stone 390 x 190 x 90 13.914410.101 12.5

Block

* Some solid units are provided with splitting guides to enable fabrication of fractions on site.

Page 3: besser block retaining wall

PriceProducts DescriptionSize (mm)l x h x w

Unitweight

(kg)

Full Length Hollow

Qty. perpallet

390 x 190 x 140 13.3114

Code

D1501.1

Unit perm2

12.5

290140

190

3/4 Length Hollow 290 x 190 x 140 11.6140D1502.1

190 140

190

1/2 Length Hollow 190 x 190 x 140 7.4200D1503.1

90 140

190

1/4 Length Hollow 90 x 190 x 140 4.1400D1504.1

340140

190

340mm Corner Block 340 x 190 x 140 11.2110D1522.1

Lintel 190 x 190 x 140 6.7257D1515.1

Notched Block 390 x 190 x 140 12.6114D1542.1

390140

90

Full Length 1/2 HeightHollow 390 x 90 x 140 6.1190D1571.1

Split Capping Unit 390 x 40 x 140 4.8270D15117

Block (Continued)

Page 4: besser block retaining wall

PriceProducts DescriptionSize (mm)l x h x w

Unitweight

(kg)

Full Length Hollow

Qty. perpallet

390 x 190 x 190 16.590

Code

D2001.1

Unit perm2

12.5

290190

190

3/4 Length Hollow 290 x 190 x 190 13.1100D2002.1

190 190

190

1/2 Length Hollow 190 x 190 x 190 8.4150D2003.1

Notched Block 390 x 190 x 190 15.690D2042.1

Full Length 1/2 HeightHollow 390 x 90 x 190 7.2150D2071.1

Capping Unit 390 x 40 x 190 6.4270D5031.1

Block (Continued)

Brick and Block Mesh30m Bundles. Available in widths of 50mm, 100mm and 150mm.

Page 5: besser block retaining wall

PriceProducts DescriptionSize (mm)l x h x w

Unitweight

(kg)

Double Wedd H Block

Qty. perpallet

390 x 190 x 190 14.390

Code

D2091.1

Unit perm2

12.5

End Block 390 x 190 x 190 14.190D2092.1

1/2 End Block 190 x 190 x 190 9.1189D2093.1

Double Webb H Block 390 x 190 x 290 19.750D3091.1 12.5

End Block 390 x 190 x 290 20.750D3092.1

1/2 End Block 190 x 190 x 290 11.8130D3093.1

Retaining Wall Systems

Base Block 290 x 140 x 290 25.660D30350

190mm Riser 190 x 190 x 190 14.7120D2033

90mm Riser 190 x 90 x 190 7.2240D1033

40mm Riser 190 x 40 x 190 3.2540D5033

Base Block Series

Page 6: besser block retaining wall

Products PriceDescriptionSize (mm)l x h x w

Unitweight

(kg)

Standard Block

Qty. perpallet

380 x 200 x 190 15.772

Code

F1991.1

Unit perm2

13

Standard Half End Block 190 x 200 x 190 8.0144F1993.1

Left Hand End Corner Block 380 x 200 x 190 14.072F1992.L

Right Hand EndCorner Block 380 x 200 x 190 14.072F1992.R

Form Bridge 190mmF19BRDG

Form Block®

Form Block® GroutingAlways refer to the Adbri Masonry Form Block® brochure when installing Form Block®190mm Series - 1m3 grout fills approx. 116 standard units.

Page 7: besser block retaining wall

Technical Information

StandardsAll Adbri Masonry concrete blockwork is manufactured to AS/NZS4455 - Masonry Units

and Segmental Pavers and tested to AS/NZS4456 - Masonry Units and Segmental Pavers/:

Methods of Test.

Fire ResistanceAS3700 - Masonry Structures sets out the method for determining fire resistance of walls

based on test data. It is recommended that designers calculate or check the structural adequacy,

integrity and insulation for each wall configuration to ensure conformance to the Building

Code of Australia (BCA). Adbri Masonry have an extensive range of bricks and blocks

meeting the requirements of the BCA. Refer to the Adbri Masonry Fire & Sound brochure

for more information.

AcousticsThe statutory requirements for sound attenuation are set out in Section F5 of the BCA.

The new BCA deemed-to-satisfy provisions increase the levels of airborne sound insulation

and apply to wall/floor systems tested in the laboratory. These figures are Rw + Ctr not less

than 50. Adbri Masonry have a number of high performance wall systems which have been

developed to accommodate the new stringent requirements imposed by the BCA, to satisfy

all acoustic needs. Refer to the Adbri Masonry Fire and Sound brochure for more information.

Control JointsControl joints must be incorporated in masonry as necessary to control and limit the

movements referred to in AS3700 clause 2.5.2.2. Control joints should extend the full height

of the wall and be spaced 8m centre for concrete units and at 6m centre for light weight

units where walls are not interrupted by full height doorways or window openings.

General GuidelinesAll concrete blockwork should be laid dry, so covering on site is recommended. Whenever work

is stopped, the tops of walls should be covered to prevent moisture entering the cores of the

blocks and/or cavity. All mortar joints should be allowed to set to “thumb print” hardness

before tooling. Brush away excess mortar with a semi stiff brush at the end of each days work.

CleaningCare should be taken to keep bricks and blocks as clean as possible during laying. There

are various methods of general cleaning from dry brushing, water washing as well as using

chemicals. For a complete listing refer to the CMAA Code MA42. When using a weak acid

mixture it is recommended for cleaning down at no stronger than 1 part acid to 20 parts

water. Walls should be wet thoroughly before application and washed thoroughly with water

after application. High water pressure is not recommended. Note: Always trial solution in

a small area which is not highly visible.

Flinders Park Kadina Hallet Cove 284 Grange Road, Flinders Park, SA 5025 86 Port Road, Kadina, SA 5554 9-11 Commercial Road, Sheidow Park, SA 5158 phone: (08) 8234 7144 I fax: (08) 8234 9644 phone: (08) 8821 2077 | fax: (08) 8821 2977 phone: (08) 8381 9142 I fax: (08) 8381 7666

Lonsdale Streaky Bay Gawler 13 Sherriffs Road, Lonsdale, SA 5160 18 Bay Road, Streaky Bay, SA 5680 Cnr Main North & Tiver Rd, Evanston, SA 5116 phone: (08) 8381 2400 I fax: (08) 8381 2366 phone: (08) 8626 7011 I mob: 0427 263 050 phone: (08) 8522 2522 I fax: (08) 8522 2488 Mount Barker Westbourne Park Gepps Cross 4 Oborn Road, Mount Barker, SA 5251 455 Goodwood Rd, Westbourne Park, SA 5041 700 Main North Road, Gepps Cross, SA 5094 phone: (08) 8391 3467 fax: (08) 8398 2518 phone: (08) 8299 9633 I fax: 08) 8299 9688phone: (08) 8349 5311 I fax: (08) 8349 5833

Mount Gambier Whyalla Holden Hill 6 Graham Road, Mount Gambier West, SA 5291 132 Norrie Ave, Whyalla Norrie, SA 5608 578 North East Road, Holden Hill, SA 5088 phone: (08) 8725 6019 I fax: (08) 8725 3724 phone: (08) 8644 0918 I mob: 0412 810 056 phone: (08) 8369 0200 I fax: (08) 8266 6855