BENEfit ®-System. Handbuch

www.psm.ms – premium implants

Prof. Dr. Benedict WilmesDüsseldorf

Page 2: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher
Page 3: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfi t® Mini Implantat:

Abutments:

Verbindung mit der Apparatur

Schraubendreher:

oder

oder

oder

oder

oder

BENEfit®-System 3

Page 4: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Die BENEfi t®-Abutments

Wilmes B., Drescher D.Benefi t – A mini-implantat system with interchangeale abutments.J Clin Orthod 2008; 42:574-580

Wilmes B., Drescher D., Nienkemper M.Beneplate – A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501

Die BENEplate-Miniplatten

VERÖFFENTLICHUNGEN:

BENEfit®-System4

Page 5: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Der BENEslider

Eine der klassischen Indikationen für eine skelettale Verankerung und insbesondere für Mini-Implantate mit Abutments stellt die Molarendistalisierung/-mesialisierung im Oberkiefer dar. Mittels des so genannten „BENEslider“ können die Molaren körperlich distalisiert werden. Mit Hilfe des Mesialsliders werden Zähne körperlich mesialisiert. So kann in vielen Fällen die Extraktion von bleibenden Zähnen und/oder dentale Implantate vermieden werden.

Zur Verbindung zweier BENEfi t® Mini-Implan tate wird eine BENEplate mit Draht auf die Im plantate geschraubt und die BENEslider Teile (Mobilisator, Federn, BENEtube) auf den Draht aufgesteckt. Die ausführende Kraft wird über eine Feder (240 g oder 500 g) mittels Mobilisator aktiviert.

Anbiegen

intraoral

am Modell

BENEfit®-System 5

Page 6: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

33-54704

10-63025

Kabello-ser Akku Schrauben-dreher

Einfaches und sicheres Implantieren durch den Kieferorthopäden

Manueller PSM Drehansatz

Anästhesie, zwei paramediane Depots

Normales Winkelhandstück (blau) mit DIN Anschluss

Vorbohrung, ca. 3 mm tief (nur bei Erwachsenen erforderlich)

Implantatinsertion

+

Der manuelle Dreh an satz wird einfach auf ein handelsübliches Winkelhandstück (blau 1:1) aufgesetzt, welches damit als Winkel schraubendreher verwendet werden kann.

Manueller Drehansatz für Winkelhand stücke

Manueller Drehansatz mod. nach Pauls, mit ein-stellbarem Drehmoment von 0 – 40 Ncm

BENEfit®-System6 Skelettale Verankerung

Page 7: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

2.3 x 11 mm2,3 x 11 mm

Dimension bei Verwendung von nur einem Mini-Implantat

BENEfit®-System 7Skelettale Verankerung

Page 8: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Mukosa posterior ca. 1 mm

Mukosa anterior ca. 3 mm

Bevorzugtes Insertionsgebiet Mediane Insertion

Abstand der Mini-Implantate: 7 – 14 mm

Paramediane Insertion

2,0 x 7 mm 2,0 x 9 mm

Ludwig B, Glasl T, Bowman J, Wilmes B, Kinzinger G, Lisson G. Anatomical Guidelines for Miniscrew Insertion: Palatal Sites. J Clin Orthod. 2011:45(8):433-441

VERÖFFENTLICHUNGEN:

Dimension bei Verwendung von zwei Mini-Implantaten

BENEfit®-System8 Skelettale Verankerung

Page 9: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

(33-54410)

Abdruckkappe

(33-54425)

Laborimplantat (Analog)

BENEfit®-System 9Herstellung im Labor

Page 10: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Molaren Distalisierung

Molaren Mesialisierung

BENEslider

Mesialslider

Hybrid Hyrax (GNE)

Temporärer Zahnersatz

Pendulum B

T-Bogen

Einordnung retinierter Zähne

Molarenaufrichtung

BENEfit®-System10

Anwendungsbeispiele

Page 11: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

(33-54535) (33-54536)

(33-54409)

BENEplate mit 1,1 mm Draht

(33-54540)

Mobilisator

BENEtube

(33-54524) Jugendliche: 240 gr. NiTi Federn

(33-54525) Erwachsene: 500 gr. NiTi Federn

BENEfit®-System 11BENEslider

Page 12: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEplate mit 1,1 mm Draht aus nichtrostendem Stahl

Wilmes B, Nienkemper M, Ludwig B, Kau CH, Pauls A, Drescher D. Esthetic Class II Treatment with the Beneslider and Aligners.JCO 2012.46:390-8 Wilmes B, Drescher D., Application and effectiveness of the Beneslider. A device to move molars distally. World J Orthod 2010;11:331–340

5,5 Monate später

VERÖFFENTLICHUNGEN

BENEfit®-System12 BENEslider

Page 13: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B, Neuschulz J, Safar M, Braumann B, Drescher D. Protocols for combining the Beneslider with lingual appliances in Class II treatment. J Clin Orthod. 2014;48:744-52

VERÖFFENTLICHUNGEN

BENEfit®-System 13BENEslider

Page 14: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEplate mit 0,8mm Stahldraht (33-54428)

oder TMA-Draht (33-54420)

Wilmes B, Katyal V, Drescher D. Mini-implant-borne Pendulum B appliance for maxillary molar distalisation: designand clinical procedure. Aust Orthod J. 2014;30:230-9

VERÖFFENTLICHUNGEN

BENEfit®-System14 Pendulum B

Page 15: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

4 Monate später

Behandlungsbeginn

BENEplate mit 0,8mm Stahldraht (33-54428)

oder TMA-Draht (33-54420)

> Gesamte Behandlungszeit: 12 Monate- 6 Monate Pendulum- 6 Monate MB

BENEfit®-System 15Pendulum B

Page 16: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit®-System16 Front-Verankerung, T-Bogen

Page 17: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Mesialslider mit schiefer Ebene zur simultanen Molarenintrusion

Wilmes B, Katyal K, Willmann J, Stocker B, Drescher D. Mini-implant-anchored Mesialslider for simultaneous mesialisation and intrusion of upper molars in an anterior open bite case: a three-year follow-up. Aust Orthod J 2015;31:87-97

VERÖFFENTLICHUNGEN

BENEfit®-System 17Mesialslider

Page 18: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEplate für die Mesialisierung

Wilmes B, Nienkemper M., Drescher D. A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher D. Palatally anchored maxillary molar mesialization using the Mesialslider. J Clin Orthod 2013.47:172-79

VERÖFFENTLICHUNGEN

(33-54541)

Mobilisator mit Haken(33-54539)

Mesialtube

NiTi Federn

BENEfit®-System18 Mesialslider

Page 19: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B, Nanda R, Nienkemper M, Ludwig B, Drescher D. Correction of upper-arch asymmetries using the Mesial-Distalslider. J Clin Orthod. 2013 ;47:648-55

VERÖFFENTLICHUNGEN:

BENEfit®-System 19Mesial-Distal-Slider

Page 20: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

33-54450 33-54452

Nienkemper M,·Wilmes B,·Pauls A, Drescher D. Preprosthetic molar uprighting using skeletal anchorage. J Clin Orthod 2013, 47:433-7

VERÖFFENTLICHUNGEN:

BENEfit®-System20 Molarenaufrichtung

Page 21: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

(33-54430)

Standard Abutment

(33-54466)

Peek Abutment

oder

Wilmes B, Nienkemper M, Renger S, Drescher D. Mini-implant-supported temporary pontics. J Clin Orthod. 2014;48:422-9

VERÖFFENTLICHUNGEN:

BENEfit®-System 21Temporärer Zahnersatz

Page 22: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

(33-54466)

BENEfi t Peek Abutment, inkl. 1 Fixationsschraube

BENEfit®-System22 Fallbeispiel

Page 23: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Brückentechnik

BENEfit®-System 23Behandlung großer Lücken

Page 24: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Nienkemper M, Wilmes B, Ludwig B, Lübberink G, Drescher D. Extrusion of impacted teeth using mini-implant-borne mechanics. J Clin Orthod.2012;46: 150-155

VERÖFFENTLICHUNG:

Abutment mit Brackets TMA-Draht 16/22”

BENEfit®-System24 Retinierte Zähne

Page 25: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B, Nienkemper M, Ludwig B, Nanda R, Drescher D. Upper-Molar Intrusion Using Anterior Palatal Anchorageand the Mousetrap Appliance. J Clin Orthod 2013.47:314-20

VERÖFFENTLICHUNG:

TPA

Intrusive force

(95-13012)

Mausefalle

Intrusionskraft

TPA

BENEfit®-System 25Molaren-Intrusion

Page 26: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B., Drescher D., Vertical Periodontal Ligament Distraction – a New Method for Aligning Ankylosed and displaced Canines. J Orofac Orthop. 2009; 70:213-223

VERÖFFENTLICHUNG:

BENEfit®-System26 Parodontale Distraktion ankylosierter Zähne

Page 27: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B, Fields of Application of Mini-Implants. In: Ludwig, Baumgaertel, Bowman: Mini-Implants in orthodontics. Innovative anchorage concepts. London, Berlin etc. Quintessence. 2008: 91- 122Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a new miniimplant and tooth-borne rapid palatal expansion device. World J Orthod. 2010Nienkemper M, Wilmes B, Franchi L, Drescher D. Effectiveness of maxillary protraction using a hybrid hyrax-facemask combination: A controlled clinical study. Angle Orthod. 2014

2x

2x

VERÖFFENTLICHUNG:

(33-54430)

BENEfi t 2.0 Schraube9 mm

2x

(33-54462)

oder

BENEfit®-System 27Hybrid-Hyrax

Page 28: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Craniale Kraftapplikation

Ziel 1: Weniger Kippung der Zähne

Ludwig B, Baumgaertel S, Kinzinger G, Zorkun B, Glasl B, Wilmes B. Application of a new visco-elastic FEM-Model and analysis of miniscrew supported Hybrid-Hyrax treatment. Am J Orthod Dentofacial Orthop 2013

VERÖFFENTLICHUNG:

BENEfit®-System28 Hybrid-Hyrax

Page 29: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Ludwig B, Glasl B, Bowman J, Drescher D, Wilmes B. Miniscrew supported Class III Treatment with the Hybrid RPE Advancer. J Clin Orthod 2010; 44:533-539Nienkemper M, Wilmes B, Pauls A, Drescher D. Maxillary protraction using a hybrid hyrax - face-mask combination. Prog Orthod 2013;14:5

VERÖFFENTLICHUNGEN:

Wilmes B, Kau CH, Ludwig B, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination J Clin Orthod, 45:1-7

Intraorale Alternative

VERÖFFENTLICHUNGEN:

Ziel 2: Vermeidung mesialer Zahnaufwanderungen, die durch die Gesichtsmaske verursacht werden können.

BENEfit®-System 29Hybrid Hyrax

Page 30: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit®-System30 Hybrid-Hyrax

Page 31: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit®-System 31Hybrid-Hyrax / Gesichtsmaske

Page 32: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a new mini-implant and tooth-borne rapid palatal expansion device. World J Orthod. 2010

Weniger Kippung

Keine Molarenaufwanderung

VERÖFFENTLICHUNGEN:

BENEfit®-System32 Hybrid-Hyrax / Gesichtsmaske

Page 33: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Abmessung (d x Länge)

2.0

33-820-04 2,0 x 4 mm33-820-05 2,0 x 5 mm33-820-07 2,0 x 7 mm

TX Bone Schraube 2,0 mm

d

Länge

7 mm

9 mm

11 mm

30 m

m

(33-850-11) (33-850-10)

(33-850-16)

(33-850-50)

(33-850-18)

(33-850-30)

(33-850-41) (33-850-20)(33-850-40)

BENEfit®-System 33MentoPlate

Page 34: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Gesichtsmaske nicht mehr notwendig

Vorteile:– die Mentoplate kann bereits vor Durchbruch der Eckzähne ab einem Alter von 8 Jahren eingesetzt werden– Öffnung der Gaumennaht (RPE Effekt)– Geringes Risiko einer Wurzelverletzung

Wilmes B, Nienkemper M, Ludwig B, Kau CH, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination. J Clin Orthod 2011; 45:1-7

VERÖFFENTLICHUNGEN:

BENEfit®-System34 Hybrid-Hyrax und MentoPlate

Page 35: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

ybridhyraxHybrid-Hyrax

MentoPlate

Wilmes B, Nienkemper M, Ludwig B, Kau CH, Drescher D. Early Class III Treatment with a Hybrid Hyrax-Mentoplate Combination. J Clin Orthod 2011; 45:1-7

VERÖFFENTLICHUNGEN:

BENEfit®-System 35Hybrid-Hyrax und MentoPlate

Page 36: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

5 Monate später

BENEfit®-System36 Hybrid-Hyrax und MentoPlate

Page 37: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit®-System 37Hybrid-Hyrax und MentoPlate

Page 38: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Vorher

Nachher

Wilmes B, Ludwig B, Katyal V, Nienkemper M, Rein A, Drescher D. The Hybrid Hyrax Distalizer, a new all-in-one appliance for rapid palatal expansion, early class III treatment and upper molar distalization. J Orthod. 2014;41:47-53

VERÖFFENTLICHUNGEN:

BENEfit®-System38 Hybrid Hyrax Distalizer

Page 39: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

Benefi t-System„A Breakthrough in Miniscrew Stability“

Robert G. Keim, Editor JCOThe Editor‘s Corner J Clin Orthod 2009.43;485-386

Keim: The Editor‘s CornerA Breakthrough in Miniscrew Stability

As with all other practical innovations in orthodontics, temporary anchorage devices (TADs) have involved a signifi cant learning curve. Although Creekmore and Eklund‘s se-minal paper on skeletal anchorage appeared in JCO more than 25 years ago,1 it remained on the fringes of the profession until around the turn of the century, when the concept took off like a rocket. Since then, paper after paper has illustrated successful treatment of most categories of malocclusion... [more]Access to the Editor‘s Corner ar free. For more free articles click here

August 2009 corner: This month‘s cover features a 30 volume rendering of a CT scan using software from Anatomage, Icc, as described in The Cutting Edge.

www.uniklinik-duesseldorf.de/kieferorthopaedie

-> Weniger Probleme

-> Sichere Mechanik

BENEfit®-System 39

Page 40: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

33-54524 240 g33-54525 500 g

BENEslider NiTi Federn, 2 Stk.

33-54536

BENEtube, lang, 2. Stk.

6,5

mm

33-54535

BENEtube, Standard für Lingualtechnik, 2. Stk.

4,5

mm

33-54535 33-54535

33-54524 33-54524

33-54540 33-54540

33-54409

33-54430

BENEfi t® Abutment Standard

33-54460 1.1 rostfreies Stahl

Abutment Standard mit 1,1 mm Draht (12 cm)

33-54425

BENEfi t® Labor/Manipulierimplantat

33-54450 Abutment mit Bracket33-54452 Abutment mit Bracket

BENEfi t® Abutment mit Brackets

33-54410

BENEfi t® Abdruckkappen

33-54543

Micro Mobilisator für 0,5 – 1,2 mm DrahtDas komplette BENEfi t-Sortiment fi nden Sie

in unserem Produktfl yer BENEfi t KAT-002.

33-54599 BENEslider Komplettset 240 gr. bestehend aus:

33-54409

33-5454033-5452433-54535

BENEplate kurz, mit 1,1 mm Draht, inkl. FixierschraubenMobilisator für 0,5 – 1,2 mm DrahtBENEslider Federn, 240 gr.BENEtube, für die Lingualtechnik

33-54597 wie 33-54599 aber mit 500 gr. Federn

steril

2.3

33-54307 2,3 x 7 mm33-54309 2,3 x 9 mm33-54311 2,3 x 11 mm33-54313 2,3 x 13 mm33-54315 2,3 x 15 mm

BENEfi t® KFO-Schraube 2,3 mm, Material Titan

steril

2.0

33-54207 2,0 x 7 mm33-54209 2,0 x 9 mm33-54211 2,0 x 11 mm33-54213 2,0 x 13 mm33-54215 2,0 x 15 mm

BENEfi t® KFO-Schraube 2,0 mm, Material Titan

BEN

Eslid

er

33-54541

Mobilisator mit Haken

33-54544

BENEtube nach Dr. Banach, mit Draht 1,1 mm, 40 mm, 2. Stk.

33-54540

Mobilisator für 0,5 – 1,2 mm Draht

33-54539

Mesialtube, mit Haken

6,5

mm

33-54463

BENEfi t® Hyrax Abutment

NEW !

33-54445

Abutment mit Öse nach Dr. S. Renger, St. Louis, Frankreich

NEW !

NEW !

73-31960 QBquattro® / BENEfi t® Sterilisierbehälter für Implantate und Instrumente, leer

33-54100 QBquattro® / BENEfi t® Instrumenten Set

NEW !

NEW !

BENEfit®-System Produktübersicht40

Page 41: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

33-54400 rostfreies Stahl

BENEplate, lang, inkl. Fixierschrauben

33-54402 rostfreies Stahl

BENEplate, kurz, inkl. Fixierschrauben

1:1

33-54409 1,1 rostfreies Stahl

BENEplate, kurz, mit 1,1 mm Draht (12 cm), inkl. Fixierschrauben

1:1

33-54408 0,8 rostfreies Stahl

BENEplate, kurz, mit 0,8 mm Stahldraht (12 cm), inkl. Fixierschrauben

1:1

33-54420 0,8 TMA

BENEplate, kurz, mit 0,8 mm TMA-Draht (12 cm), inkl. Fixierschrauben

1:1

1:1

33-54428 0,8 rostfreies Stahl

BENEplate, lang, mit 0,8 mm Draht (12 cm), inkl. Fixierschrauben

1:1

33-54429 1,1 rostfreies Stahl

BENEplate, lang, mit 1,1 mm Draht (12 cm), inkl. Fixierschrauben

1:1

120 mm

1:1

33-54407

BENEplate lang, mit Bracket inkl. Fixierschrauben

1:1

33-54403

Ersatz Fixierschrauben, 2 Stk.

12,5 mm17,5 mm

10-67513 QB DENTAL

Bohrer, 1,4 x 33 mm AT 15 mm, rot für 2,0 mm Schrauben

für 2,0 mm Schrauben

11-18452 QB DENTAL

Bohrer, 1,8 x 33 mm AT 15 mm, grau für 2,3 mm Schrauben

für 2,3 mm Schrauben

33-54704 QBManueller Drehansatz mod. nach Pauls, mit einstellbarem Drehmoment von 0 – 40 Ncm

10-63025 QBManueller Drehansatz für Winkelhand stücke

33-55000

BENEfi t® Starter Instrument Kit Set

73-31990

BENEfi t® Starter Behälter, leer

33-54462

Hyrax Ring, inkl. Fixa-tionsschrauben, 2 Stk.

33-54466

BENEfi t Peek Abutment, inkl. 1 Fixationsschraube

33-54533

FlexiTube, 2 Stk.

NEW !

NEW !

33-18266 QBHandgriff für Instrumente mit Dental-ansatz mit begrenztem Drehmoment (10 Ncm)

NEW !

BENEfit®-System 41Produktübersicht

Page 42: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

95-13001

Modell BENEslider, mesial., distal.

95-13003

Modell Pendulum B

95-13005

Modell Molarenaufrichtung

95-13007

Modell Frontverankerung

95-13009

Modell „Temporäres Implantat“

95-13002

Modell Molarenverankerung

95-13006

Modell Hybridhyrax

95-13008

Modell Zahnretention

95-13011

Gipsmodell mit Laborimplantaten

NEW !NEW !

95-13014

Modell T-Mesial/Distalslider

95-13012

Modell Mausefalle

95-13013

Modell Hybridhyrax Distalizer

95-13015

Modell Hybridhyrax Distalizer 2

V-90-994-02

BENEfi t® Modellkoffer für 18 Modelle, leer

V-90-994-00

BENEfi t® Modellkoffer für 9 Modelle, leer

BENEfit®-System Produktübersicht42

Page 43: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit®-System 43ProduktübersichtNotes

Page 44: BENEfit -System. Handbuch · A miniplate system for improved stability of skeletal anchorage. J Clin Orthod 2009; 43:494-501 Wilmes B, Nienkemper M, Nanda R, Lübberink G, Drescher

BENEfit ®-System. Handbuch

Mehr Informationen unter: www.psm.ms

Hersteller:

psm MEDICAL SOLUTIONS

Moltkestraße 4178532 Tuttlingen

Telefon +49 ( 74 61) 9 66 37-0Fax +49 ( 74 61) 9 66 37-29

E-Mail [email protected] www.psm.ms

Vertrieb in der USA:

psm North America

P.O. Box 14249950 Jefferson Street

Suite 130, Indio, CA 92201

Toll-free: 800-733-1622

E-Mail [email protected] www.psm-na.us

www.psm.ms – premium implants

Verkauf in D, A, CH:

DENTALLINE GmbH & Co. KG

Goethestraße 4775217 Birkenfeld

Telefon +49 7231 97810

E-Mail [email protected] www.dentalline.de

KAT

-012

| 0

9.15

| Re

v. 1

F

RIC

ON

.de