Belco Electric Residential

20

description

Home Inspections

Transcript of Belco Electric Residential

Page 1: Belco Electric Residential
Page 2: Belco Electric Residential

Common Electrical Home Common Electrical Home Inspection ItemsInspection Items

Service WiresService Wires

Grounding SystemGrounding System

PanelPanel

DevicesDevices

Aluminum WiringAluminum Wiring

Outdoor WiringOutdoor Wiring

Page 3: Belco Electric Residential

Service WiresService Wires(Service Entrance Conductors)(Service Entrance Conductors)

Note Existence of WeatherheadNote Existence of Weatherhead Is weatherhead secured to structureIs weatherhead secured to structure Is there an eyebolt presentIs there an eyebolt present

Check Condition of Service CableCheck Condition of Service Cable Deteriorated insulation on conductorsDeteriorated insulation on conductors Deterioration of outer covering of cableDeterioration of outer covering of cable

Page 4: Belco Electric Residential

Deteriorated Insulation

Page 5: Belco Electric Residential

Grounding SystemGrounding System

Grounding Electrode ConductorGrounding Electrode Conductor Connected within 5’ of waterline entranceConnected within 5’ of waterline entrance Must be continuous wireMust be continuous wire Originate from 1Originate from 1stst means of disconnect means of disconnect

Ground RodGround Rod At least 6 ft apart if more than oneAt least 6 ft apart if more than one

Page 6: Belco Electric Residential

Splice in Grounding Electrode Conductor (wire must be one continuous length)

Page 7: Belco Electric Residential

Electrical PanelElectrical Panel

Double TapsDouble Taps

Incorrect Circuit SizingIncorrect Circuit Sizing Exceptions for A/C and motor loadsExceptions for A/C and motor loads

Space availableSpace available

Non Listed BreakersNon Listed Breakers

Beware certain manufacturersBeware certain manufacturers

Page 8: Belco Electric Residential

Not Double Tapped (code compliant)

Double Tapped (code violation)

Page 9: Belco Electric Residential

This breaker is designed for(1) or (2) wires connected at the lug.

Page 10: Belco Electric Residential

Split Buss Panel Label

Page 11: Belco Electric Residential

Standard Panel Label

Page 12: Belco Electric Residential

A/C Name Plate Provides Information on Branch Circuit Requirements

Min. Wire Size

Max. Breaker Size

Min. Breaker Size

Page 13: Belco Electric Residential

Aluminum WiringAluminum Wiring

Concerns of AluminumConcerns of Aluminum

Devices Compatible with AluminumDevices Compatible with Aluminum

AL / CU Wire NutsAL / CU Wire Nuts

Page 14: Belco Electric Residential

Aluminum & Copper Rated Switch

Copper Only Switch

Page 15: Belco Electric Residential

Improper CO/AL Splice Caused Excessive Heat Buildup and Failure of Copper Only Wire Nut

Page 16: Belco Electric Residential

Proper Use of MaterialsProper Use of Materials

Lamp CordLamp Cord

Areas Considered Wet LocationsAreas Considered Wet Locations

Underground WiringUnderground Wiring

Junction BoxesJunction Boxes

Page 17: Belco Electric Residential

LAMP CORD RUN THROUGH WALL (use not permitted)

Page 18: Belco Electric Residential

Not Properly Secured and Supported Wire

Page 19: Belco Electric Residential

Open J-box Behind Stove (box should be secured & covered & all taps made within the box)

Page 20: Belco Electric Residential

Improperly Installed Attic Junction Box (box is not covered and is not secured to joist)