Bef 23901 Chapter 1 Measurement and Errors
description
Transcript of Bef 23901 Chapter 1 Measurement and Errors
![Page 1: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/1.jpg)
CHAPTER 1
MEASUREMENT AND ERRORS
![Page 2: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/2.jpg)
Principles of Measurement
Measurement is the process of comparing an unknown quantity with an accepted standard quantity.
It involves connecting a measuring instrument into the system under consideration and observing the resulting response on the instrument.
The term measurement can also be used to refer to a specific result obtained from the measurement process.
Electrical Measurement (BEF 23903) 2
Measurand (Unknown quantity to be measured)
Process of comparison (measurement)
Standard (known quantity)
Result
(Read out)
![Page 3: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/3.jpg)
Measurand
• The physical quantity or the characteristic condition which is the object of measurement in an instrumentation system.
• Also called i. Measurement variable
ii. Instrumentation variable
iii. Process variable
• The measurand may be:
- Fundamental quantity, e.g. length, mass, and time;
- Derived quantity, e.g. speed, velocity, acceleration.
Electrical Measurement (BEF 23903) 3
![Page 4: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/4.jpg)
Before measurement process we have to ensure:
Methods/procedures of measurement
Characteristics of the parameter
Quality: time and cost, instrument capabilities, knowledge of measurement, acceptable result
What instrument to use
During the measurements we have to ensure:
Quality- best instrument chosen, suitable position when taking the data, etc..
Safety- electric shock, overloaded, instrument limits, read instruction manual
Sampling – observe parameter changing, taking enough sample
After measurement Analyse the data mathematically/statistically Full result must be reported completely and accurately
Electrical Measurement (BEF 23903) 4
![Page 5: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/5.jpg)
What is an instrument?
1. Device that communicates, denotes, detects, indicates, measures, observes, records, or signals a quantity or phenomenon, or controlsor manipulates another device.
2. A tool or device used for a particular purpose; especially : a tool or device designed to do careful and exact work.
Electrical Measurement (BEF 23903) 5
![Page 6: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/6.jpg)
Instrumentation
• The technology of using instruments to measure and control the physical and chemical properties of materials is called instrumentation.
• When the instruments are used for the measurement and control of industrial manufacturing, conversion or treatment process, the term “process instrumentation” is used.
• When the measurement and control instruments are combined so that measurements provide impulse for remote automatic action, the result is called a Control system.
Electrical Measurement (BEF 23903) 6
![Page 7: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/7.jpg)
The basic requirements for getting meaningful result of measurement are:
1. The standard employed for comparison purpose may be accurately defined and should be commonly acceptable.
2. The standard must be of the same character as the measurand and usually but not always, is prescribed and defined by a legal or recognised organisation, e.g. the International Organisation of Standards (ISO).
3. The apparatus used and method adopted for the comparison purposes must be provable.
Electrical Measurement (BEF 23903) 7
![Page 8: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/8.jpg)
Why do we need measurements?
The significance of measurement is discussed below:
1. Measurement plays a very significant role in every branch of scientific research and engineering processes which include the following:
- Control systems;
- Process instrumentation
- Data reduction.
2. The whole area of automation or automatic control is based on measurements. The very concept of control is based on the comparison of the actual condition and the desired performance. The exactness of error depends on the precision and accuracy of measurement made.
Electrical Measurement (BEF 23903) 8
![Page 9: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/9.jpg)
Why do we need measurements?
3. The measurements confirm the validity of a hypothesis and also add to its understanding. This eventually leads to new discoveries that require new and sophisticated measuring techniques.
4. Through measurements a product can be designed or a process be operated with maximum efficiency, minimum cost, and with desired degree of reliability and maintainability.
Electrical Measurement (BEF 23903) 9
![Page 10: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/10.jpg)
SI Systems
S.I Unit
Base units Derived unitsSupplementary
units
Electrical Measurement (BEF 23903) 10
International system of units (S.I) are divided into three classes:
![Page 11: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/11.jpg)
S.I Base Units
Electrical Measurement (BEF 23903) 11
Base Quantity Base Unit
Name Symbol
Length Meter m
Mass Kilogram Kg
Time Second s
Electric Current Ampere A
Thermodynamic Temperature Kelvin K
Amount of substance Mole mol
Luminous Intensity Candela cd
![Page 12: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/12.jpg)
Derived Unit
• Derived Quantities are formed by combining two or more of the fundamental quantities.
Examples:
Area = length x width
Volume = length x width x height
Speed = distance/time
Density = mass/volume
Most of the units in the International System are derived units, that is units defined in terms of base units and supplementary units. Derived units can be divided into two groups - those that have a special name and symbol, and those that do not.
Electrical Measurement (BEF 23903) 12
![Page 13: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/13.jpg)
Electrical Measurement (BEF 23903) 13
Without Names and Symbols
Measure of Derivation
acceleration m/s2
angular acceleration rad/s2
angular velocity rad/s
density kg/m3
electric field strength V/m
magnetic field strength A/m
velocity m/s
![Page 14: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/14.jpg)
Electrical Measurement (BEF 23903) 14
With Names and Symbols
Unit Measure of Symbol Derivation
coulomb electric charge C A·s
farad electric capacitance F A·s/V
henry inductance H V·s/A
hertz frequency Hz cycles/s
joule quantity of energy J N·m
ohm electric resistance Ω V/A
tesla magnetic flux density T Wb/m2
volt voltage V W/A
watt power W J/s
weber magnetic flux Wb V·s
![Page 15: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/15.jpg)
Supplementary Units
Third class of S.I units
Supplementary units may be regarded either as base units or as derived units
Example of S.I derived units formed by using supplementary units
- Angular velocity ( )
- Angular acceleration ( )
Electrical Measurement (BEF 23903) 15
Quantity S.I Units
Name Symbol
Plane angle radian rad
Solid angle steradian sr
2/ srad
srad /
![Page 16: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/16.jpg)
Instrument’s Performance Characteristic
Performance Characteristics - characteristics that show the performance of an instrument.
Allows users to select the most suitable instrument for a specific measuring jobs.
Two basic characteristics :
1. Static
2. Dynamic
Electrical Measurement (BEF 23903) 16
![Page 17: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/17.jpg)
Static Characteristic
I. Accuracy – the degree of exactness (closeness) of measurement
compared to the expected (desired) value.
II. Resolution – the smallest change in a measurement variable to which an
instrument will respond.
III. Precision – a measure of consistency or repeatability of measurement,
i.e successive reading do not differ.
IV. Sensitivity – ratio of change in the output (response) of instrument to a
change of input or measured variable.
V. Error – the deviation of the true value from the desired value
Electrical Measurement (BEF 23903) 17
![Page 18: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/18.jpg)
Errors in Measurement
Various types of errors in measurement:
i. Absolute error
ii. Gross Errors
iii. Systematic Error
iv. Random Error
v. Limiting Error
Static error of a measuring instrument – The numerical difference between the true value of a quantity and its value as obtained by measurement (i.e. repeated measurement of the same quantity gives different indications).
Electrical Measurement (BEF 23903) 18
![Page 19: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/19.jpg)
i) Absolute error
Error - The difference between the expected value of the variable and the measured value of the variable:
e = Yn – Xn
where:
e = absolute error
Yn = expected value
Xn = measured value
Percentage Error:
Electrical Measurement (BEF 23903) 19
100
nYnXnY
% error =
![Page 20: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/20.jpg)
Relative accuracy (A):
% Accuracy:
a = 100% - % error
=
Precision:
Electrical Measurement (BEF 23903) 20
n
nn
Y
XYA
1
n
nn
X
XXP
1
100A
Wherevalue of the nth measurement
average set of measurement
nX
nX
![Page 21: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/21.jpg)
Example 1.1
Given expected voltage value across a resistor is 80V. The measurement is 79V. Calculate,
1. The absolute error
2. The % of error
3. The relative accuracy
4. The % of accuracy
Electrical Measurement (BEF 23903) 21
![Page 22: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/22.jpg)
Solution 1.1
Electrical Measurement (BEF 23903) 22
![Page 23: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/23.jpg)
Example 1.2
From the value in table below, calculate the precision of 6th
measurement?
Electrical Measurement (BEF 23903) 23
No Xn
1 98
2 101
3 102
4 97
5 101
6 100
7 103
8 98
9 106
10 99
![Page 24: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/24.jpg)
Solution 1.2
Electrical Measurement (BEF 23903) 24
![Page 25: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/25.jpg)
ii) Gross Error
Due to human mistakes in reading or in using instruments or error in recording observations.
Example: incorrect reading, incorrect recording, improper use of instruments, etc.
To minimize:
Take at least 3 separate reading.
Take proper care in reading & recording.
Electrical Measurement (BEF 23903) 25
![Page 26: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/26.jpg)
iii) Systematic Error
Due to shortcoming of the instruments or environmental effects or observational errors.
example
defective or worn parts
ageing
parallax error
wrong estimation reading scale
Electrical Measurement (BEF 23903) 26
![Page 27: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/27.jpg)
Types of Systematic Errorsa) Instrumental errors : Due to friction in the bearings of the meter movement, incorrect spring
tension, improper calibration, or faulty instruments. Can be reduced by proper maintenance, use, and handling of instruments.
b) Environmental errors : Due to external condition of the measuring device. Example: effects of change in temperature, humidity, barometric pressure,
electrostatic fields etc. Can be avoided by: air conditioning, hermetically sealing certain
components in the instrument and using magnetic shields.
c) Observational errors : Errors that introduced by the observer. The two most common observational errors are probably the parallax
error introduced in reading a meter scale and the error of estimation when obtaining a reading from a meter scale.
Electrical Measurement (BEF 23903) 27
![Page 28: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/28.jpg)
Example 1.3 (a)
A voltmeter having a sensitivity of 1 k/V is connected across an unknown resistance in series with a milliammeter reading 80 V on 150 V scale. When the milliammeter reads 10 mA, calculate the
i. apparent resistance of the unknown resistance,
ii. actual resistance of the unknown resistance, and
iii. error due to the loading effect of the voltmeter.
Electrical Measurement (BEF 23903) 28
![Page 29: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/29.jpg)
Solution 1.3(a)
Electrical Measurement (BEF 23903) 29
![Page 30: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/30.jpg)
Example 1.3 (b)
Referring to example 1.3 (a), if the milliammeter reads 600 mA and the voltmeter reads 30 V on a 150 V scale, calculate the following:
i. Apparent, resistance of the unknown resistance,
ii. Actual resistance of the unknown resistance,
iii. Error due to loading effect of the voltmeter.
Comment on the loading effect due to the voltmeter for both Examples 1.3 (a) and (b). (Voltmeter sensitivity given 1000 /V.)
Electrical Measurement (BEF 23903) 30
![Page 31: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/31.jpg)
Solution 1.3(b)
Electrical Measurement (BEF 23903) 31
![Page 32: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/32.jpg)
iv) Random Errors
Errors that remain after gross and systematic errors have been substantially reduced.
Are generally the accumulation of a large number of small effects.
May be of real concern only in measurements requiring a high degree of accuracy.
Such errors can only be analyzed statistically.
These errors are due to unknown causes, not determinable in the ordinary process of making measurements.
Electrical Measurement (BEF 23903) 32
![Page 33: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/33.jpg)
iv) Limiting Errors
Most manufacturers of instruments state that an instrument is accurate within a certain percentage of a full-scale reading.
Eg: a voltmeter is accurate within ±2% at full-scale deflection (limiting errors).
However, with reading less than full-scale, the limiting error will increase.
therefore, it is important to obtain measurements as close as possible to full scale
Electrical Measurement (BEF 23903) 33
![Page 34: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/34.jpg)
Example 1.4
A 300-V voltmeter is specified to be accurate within ±2% at full scale. Calculate the limiting error when the instrument is used to measure a 120-V source?
Electrical Measurement (BEF 23903) 34
![Page 35: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/35.jpg)
Solution 1.4
Electrical Measurement (BEF 23903) 35
![Page 36: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/36.jpg)
Example 1.5
A voltmeter reading 70 V on its 100 V range and an ammeter reading 80 mA on its 150 mA range are used to determine the power dissipated in a resistor. Both these instruments are guaranteed to be accurate within ±1.5% at full scale deflection. Determine the limiting error of the power.
Electrical Measurement (BEF 23903) 36
![Page 37: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/37.jpg)
Solution 1.5
Electrical Measurement (BEF 23903) 37
![Page 38: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/38.jpg)
Dynamic Characteristic
Dynamic – measuring a varying process condition.
Instruments rarely respond instantaneously to changes in the measured variables due to such things as mass, thermal capacitance, fluid capacitance or electrical capacitance.
The dynamic characteristics of an instrument are:
I. Speed of response
II. Dynamic errorThe difference between the true and measured value with no static error.
III. Lag – response delay
IV. Fidelity – the degree to which an instrument indicates the changes in the measured variable without dynamic error (faithful reproduction).
Electrical Measurement (BEF 23903) 38
![Page 39: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/39.jpg)
Statistical Analysis of Measurement Data
Important because it allows an analytical determination of the uncertainty of the final result.
A large number of measurements is usually required.
Can be divided into 4:
Electrical Measurement (BEF 23903) 39
Arithmetic mean / Average
Deviation
Average deviation
Standard deviation
i
ii
iii
iv
![Page 40: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/40.jpg)
i) Arithmetic mean/average:
The most probable value of measured variable.
The best approximation when the number of readings the same quantity is very large.
Electrical Measurement (BEF 23903) 40
n
1i
n321 x x x x
n
x
nx i
n = total number of readingxn = nth reading takenxi = set of number
![Page 41: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/41.jpg)
ii) Deviation:
The difference between each piece of data and arithmetic mean
Algebraic sum of deviation,
Electrical Measurement (BEF 23903) 41
xxd nn
1 1d x x
2 2d x x
0 21 ntotal dddd
![Page 42: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/42.jpg)
iii) Average deviation (D):
Indication of the precision of a measuring instrument used in measuremnt
high D low precision
low D high precision
Electrical Measurement (BEF 23903) 42
n
dddD n
21
![Page 43: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/43.jpg)
iv) Standard Deviation
Also known as root mean square deviation.
The most important factor in statistical analysis.
Reduction means improvement in measurement.
Electrical Measurement (BEF 23903) 43
2 2 2 2
1 2 3 ....
1
nd d d d
n
2
1
nd
n
![Page 44: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/44.jpg)
Example 1.4
Electrical Measurement (BEF 23903) 44
For the following data
Compute:
(a) The arithmetic mean.
(b) The deviation of each value.
(c) The algebraic sum of the deviation.
(d) The average deviation.
(e) The standard deviation.
No. 𝑥𝑛
1 49.7
2 50.1
3 50.2
4 49.6
5 49.7
![Page 45: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/45.jpg)
Solution 1.4
Electrical Measurement (BEF 23903) 45
![Page 46: Bef 23901 Chapter 1 Measurement and Errors](https://reader034.fdocuments.in/reader034/viewer/2022042522/55cf912a550346f57b8b4b93/html5/thumbnails/46.jpg)
END
Electrical Measurement (BEF 23903) 46