Beaver Valley Power Station PO. Box 4 FirstEnergy …July 25, 2005 L-05-1 25 U. S. Nuclear...
Transcript of Beaver Valley Power Station PO. Box 4 FirstEnergy …July 25, 2005 L-05-1 25 U. S. Nuclear...
FENOC Beaver Valley Power Station
PO. Box 4FirstEnergy Nuclear Operating Company Shippingport. PA 15077-0004
L William Pearce 724-682-5234Vice President Fax: 724-643-8069
July 25, 2005
L-05-1 25
U. S. Nuclear Regulatory CommissionAttention: Document Control DeskWashington, DC 20555-0001
Subject: Beaver Valley Power Station, Unit No. 2Docket No. 50-412, License No. NPF-73Eleventh Refueling Outage Inservice Inspection Report
This letter forwards the Inservice Inspection (ISI) Ninety-Day report on ASME Class 1and 2 components examined during the Eleventh refueling outage (2R1 1) at BeaverValley Power Station (BVPS) Unit 2. The ASME Boiler and Pressure Vessel Code,Section Xl, Article IWA-6230 requires that an inservice inspection report be submittedto the enforcement and regulatory authority having jurisdiction at the plant site withinninety days after completion of an inservice inspection. The recent inservice inspectionterm at BVPS Unit 2 ended on April 27, 2005.
The Class I and 2 examinations are part of Interval 2, Period 2 of the Unit 2 ISIschedule, and were performed in accordance with Chapter XI, Section IWA-6230 of theASME Boiler and Pressure Vessel Code, 1989 Edition.
There are no new regulatory commitments identified in this document. If you have anyquestions concerning this matter, please contact Mr. Larry R. Freeland, Manager,Regulatory Compliance at 724-682-4284.
Sincerely,
(S. Pearce
Attachment
c: Mr. T. G. Colburn, Project ManagerMr. P. C. Cataldo, Sr. Resident InspectorMr. S. J. Collins, NRC Region I AdministratorMr. J. Payton, Commonwealth of Pennsylvania
i/Th
BEAVER VALLEY POWER STATION UNIT 2Route 168, Shippingport, PA
Outage 11, Year 2005
Inspection Term: 10/11/2003 to 4/27/2005
Issue date: 7- l -05
Owner: FirstEnergy76 South Main St.Akron, OH 44308
NRC Docket Number: 50-412
Reactor Supplier: Westinghouse Electric CorporationCommercialServiceDate: Novemberl17, 1987
Prepared by: / -
Reviewed buclear Programs
Date: 7_ 1_ ____ _
Date: 7-i5-c
Reviewed by:ANII
Date: -/-S- 0 ---
.
Approved by: c2t, P1>~ t. c .Re
Manager, Technical Services EngineeringDate: _7-l__T -
-1-
90-DAY REPORTTABLE OF CONTENTS
Item Page Number
Cover Page
Table of Contents
Form NIS-1
Outage Summary
ASME XI Vessel, Piping and Support Examinations
1. Class 12. Class 2
Pressure Testing
Deficiency Resolution
Steam Generator Tube Examination
NIS-2 Forms
Appendix I - Completed Code Examinations
Appendix II - Repair/Replacement Abstract and NIS-2 Forms
I
2
3 - 4
5
5
5
6
6
6
6
(2 pages total)
(69 pages total)
-2-
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONSAs required by the Provisions of the ASME Code Rules
1. Owner FirstEnergy Nuclear Operating Company, Route i68, Shippingport, PA 15077(Name and Address of Owner)
2. Plant Beaver Valley Power Station, Route 168, Shippingport, PA 15077(Name and Address of Plant)
3. Plant Unit 2 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date i1/17/87 6. National Board Number for Unit N/A11. 17..7.N.A
7. Components Inspected
Manufacturer orComponent or Manufacturer or Installer State or NationalAppurtenance Installer 'Serial No. -Province No. Board No.
Reactor CoolantPiping Southwest Fabricating N/A N/A N/AAuxiliaryPiping Schneider Power N/A N/A N/A
2RCS-REV21 Combustion Engineecring CE-9071 160591 B 21669
2RCS-P21A Westinghouse Electric Corp W-11001-AI(93-A) N/A NIA
2RCS-SG2. A Westinghouse Electric Corp DMGT-1961 485065V W-16598
2RCS-SG21B Westinghouse Electric Corp DMGT-1962 485066V W-16599
2RCS-SG21C -. Westinghouse Electric Corp* DMGT-1963 485067V W-16600
2RHS-E-21A Atlas Industrial Mfg Co. 43483 85068V 2853
Note Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8V in. x 11 in.,(2) information in items I though 6 on this report is included on each sheet, and (3) each sheet is numbered andthe number of sheets is recorded at the top or this form.
Tbis form (E0029) tmy be obtaied from the ASME Order Dept. 22 Law Drive. Box 2300. Iairfiekd NJ 07008-2300
-3-
I ;LIa
FORAM NIS-1 (Back)
8. Examination Dates . 10/11/2003 to 4/27/2005
9. Inspection Period Identification: 12/2912001 to 4/29/2005
10. Inspection Interval Identification: 11/17/1997 to 08/28/2008
11. Applicable Edition of Section XI 1989 Addenda None
12. Date/Revision of Inspection Plan: 1/2-ADM-2039. Revision 2
13. Abstract of Examination and Tests. Include a list of examinations and tests and a statement concerning status of work requiredfor the Inspection Plan. See Appendix I (Code Exams) for examinations performed during 2R11. 2R111 was the third andfinal outage in the 2n Period of the 2'd Ten-Year Interval. All examinations required to meet the ASME XI percentagerequirements for the 2d 40-Nfonth Period have been completted.
14. Abstract of Resultsof Examination and Tests. See text of surnmary report.
15. Abstract of Corrective Measures. No Corrective measures resu1ting from NDE ISI examinations were required in 2R11.
We certify that a) the statements ndade in this report are correct, b) the examinations and tests meet the Inspection Planas required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XL
Certificate of Authorization No. (if applicable) N/A Expiration Date N/ADate 7-1`5 -0 e Signed . FtrstEnergy Nuclear Operating Co. By
(Owner)
CERTIFICATE OF INSERVICE INSPECTION.
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of* Pennsylvania and employed by * * HSB CT . of
Hartford, CT . . have inspected the components described in this Owner's Report during the period10/11/2003 to 4/27/2005 and state that to the best of my knowledge and betef, the
Owner has performed examinations and tests and taken corrective measures described in this Owner's Report in accordancewith the Inspection Plan and as required by the AS ME Code, Section XL
By signing this certificate neither the Inspector nor his employer make any.warranty, expressed or implied, concerningthe examinations, tests, and corrective measures described in this Owner's Report. Furthermore, neither the Inspectornor.his employer shalt be liable in any manner for any personal injury or property damage or a loss ofany kind arisingfrom or connected with ts inspection .
Commissions NB 9428 ANIB, PA 2384Inspect ignature National Board. State, Province and Endorsements
Date * 7-/5- O F
-4-
OUTAGE SUMMARY
During the Eleventh Refueling Outage (2R1 1) at the Beaver Valley Power Station,Unit 2, Inservice Inspection (ISI) examinations were performed on Class 1 and 2. This was thethird outage in the second period of the second ten year interval. Also included in this report andthe counts below are examinations performed prior to 2Rl I during plant operation. Theexaminations were based on ASME Section XI, 1989 Edition.
ASME XI Class 1 and 2 Credited Exams (See Appendix I)
1. Thirty-one (31) Class 1 exams were performed and are divided as follows:
a. Pipe WeldsUltransonic Exam - 1Visual Exams - 2
b. Reactor Vessel Interior SurfacesVisual Exam - 1
c. Steam Generator Inner Radius SectionVisual Exams - 2
d. Reactor Coolant PumpUltasonic Exams (bolting) - 24Visual Exam (flange) - 1
2. Thirty-four (34) Class 2 exams were performed and are divided as follows:
a. Welds (vessels and piping)Ultrasonic Exams - 9Penetrant Exams - 2Visual Exams - 23
Examinations were performed by FirstEnergy Nuclear Operating Company (FENOC) andcontracted NDE Technicians. Appendix I compiles the examinations that have been creditedtoward fulfilling the Ten Year Plan requirements.
-5-
Pressure Testing
The Class 1 piping System Leakage Test was performed prior to plant start-up. All Class 1bolted connections subject to the examination requirements of IWA-5242, "InsulatedComponents" and Code Case N-533-1, "Alternate requirements for VT-2 Visual Examination ofClass 1, 2 and 3 Insulated Pressure Retaining Bolted Connections" were examined during 2R1 1.Also, Class 2 and 3 system functional and system inservice tests were performed on varioussystems to fulfill the current 40-month pressure testing requirement.
Deficiency Resolution
There were no ISI non-destructive examination deficiencies in 2R1 1.
Steam Generator Tube Examination
One hundred percent of the in-service tubes were examined in the three steam generators.Results of the examinations are submitted to regulatory authorities in accordance with TechnicalSpecification requirements.
NIS-2 Forms
Included as Appendix H are the NIS-2 Forms associated with repairs and replacements. CodeCase N-416, Alternative Pressure Test Requirement for Welded Repairs or Installation ofReplacement Items by Welding, Class 1, 2 and 3, was used. The revision of Record at BVPS forCode Case N-416 is currently Revision 2. However, some of the attached NIS-2 Forms had beeninitiated and/or completed prior to implementation of Revision 2. The NIS-2 specifies whenN-416 was implemented and the specific revision used.
-6-
APPENDIX I
COMPLETED CODE EXAMINATIONS
APPENDIX I2R1 1 Completed Code Exams
SUMMARY COMPONENT ID CLASS CATEGORY ITEM NO DESCRIPTION NDEME1142600154630154660192500196500209700246400246500307650314050317450324650325800332250342500373850387200389400389600390200397700397900434700511008573400573700573800573900643350669250681350717050725150737450749000751450771050772400
2RCS-004-F032RCS-044-F072RCS-024-S032RCS*P21A(F)-B0I TO B242RCS*P21 A-LIG2RCS*REV21 -INT2RCS*SG21 C-N-3AIR2RCS*SG21 C-N-3BIR2BDG-68-F-122CHS-434-F022CHS-433-F022CHS-291-F4032CHS-320-F4042CHS-124-F4092CHS-207-F022CHS-056-FI32CHS-356-1 B2CHS-278-F4002CHS-278-F4012CHS-279-F500A2CHS-272-F4002CHS-272-F4012CHS-149-F252QSS-004-15B2RHS*E21A-C-22RHS*E21A-N-32RHS*E21A-N-42RHS*E21A-C-12SIS-305-F-022SIS-167-F-012SIS-392-F112SIS-093-F4012SIS-393-F232SIS-215-F21A2SIS-104-142SIS-377-172SIS-365-22SIS-102-8A
B-JR-AR-AB-G-1B-G-1B-N-1B-DB-DR-AR-AR-AR-AC-F-IR-AC-F-1R-AC-F-1C-F-IC-F-IC-F-IC-F-1C-F-1R-AC-F-IC-AC-BC-BC-AR-AR-AR-AR-AR-AR-AC-F-IR-AR-AC-F-1
B09.011Rl-ISIRI-ISIB06.180B06.190B13.010B03.140B03.140RI-ISIRI-ISIRl-ISIRI-ISIC05.030RI-ISIC05.030RI-ISIC05.021C05.030C05.030C05.021C05.030C05.030RI-ISIC05.011C01.020C02.021C02.021C01.010RI-ISIRl-ISIRI-ISIRl-ISIRI-ISIRI-ISIC05.030RI-ISIRI-ISIC05.021
PIPE WELDSOCKET WELDSOCKET WELDMAIN FLANGE BOLTFLANGE LIGAMENTSVESSEL INTERIORNOZZLE INSIDE RADIUSNOZZLE INSIDE RADIUSSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDBUTT WELDSOCKET WELDSOCKET WELDBUTT WELDSOCKET WELDSOCKET WELDSOCKET WELDBUTT WELDHEAD CIRCUMFERENTIAL WELD # 2NOZZLE-TO-SHELL WELD # 3NOZZLE-TO-SHELL WELD # 4SHELL CIRCUMFERENTIAL WELD # 1SOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDSOCKET WELDBUTT WELD
UT,,VT-2,VT-2,UT, ,VT-1,,VT-3,VT-I,,VT-1,,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,UT,,VT-2,,VT-2,UT,VT-2,VT-2,VT-2,UT,UT,UT ,PT,UT ,PT,UT,,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,VT-2,UT,,
FHOD ISO-NO110230110454110456E-1CE-1CE-IAE-1 BE-1 B110447108301108302108304108304108306108313410-766108396108396108396108396108398108398110298107938E-2PE-2PE-2PE-2P108103108111410-548109932510-258110165110178110274110-0091107138
Page Al-i
al
APPENDIX I2R1 I Completed Code Exams
SUMMARY COMPONENT ID787750 2SIS-375-F402800200 2SVS-1 1 -6AB
CLASS CATEGORY ITEM NO2 R-A RI-ISI2 C-F-2 C05.051
DESCRIPTIONSOCKET WELDBUTT WELD
NDEMETHODVT-2, ,
UT, , .
ISO-NO110798100216
Page AI-2
APPENDIX II
REPAIR / REPLACEMENT ABSTRACTAND
NIS-2 FORMS
FORM NO.14401563161816201663167016791680168416921695169617011702170317041705170617291732173317341755176817831784178617881789179017911792179317941795
17961797179817991800
1804
ASSET NUMBER2RCS-PCV455C2SWS-6922SWS-4812SWS-4832CHS-RV2572SWS-1 2722RCS-RV551 C spare2CCP-52SWS-1502QSS-SOV1 02B2FN C-1082SVS-HCV1042SVS-PCV101A2SVS-PCV101B2SVS-PCV101 C2-SWS-030-143-32CHS-422SWS-1072RHS-RV721A2QSS-PSSP154X2SWS-MOV105A2SWS-MOV105C2CHS-4842SWS-582SVS-812SVS-822CHS-RV382B2MSS-192RSS-E21 A2FWE-992FWE-1012RCS-SG21A2RCS-SG21 B2RCS-SG21 C2SIS-PSSP006A2SIS-PSSP366Y2MSS-PSSPOO62RCS-PSSP035X2FPW-7612SWS-1 2302RCS-RV551A
2SWS-57
NIS-2 ABSTRACTORDER NO.200021177200016534200016001200016048200014878200067892200072791200014967200021737200088962200065869200106067200016894200136936200075699200094959200029304200061984200020473200028819200029381200029404200087074200057451200079051200079052200027180200114344200016207200094915200094914702482970248297024829200028841
200028814200028761200022184200148005200148055200063831200055515
COMMENTSCorrectedRemovedRemovedRemovedRemovedInstalledCorrectedReplacedCorrectedCorrectedCorrectedCorrectedCorrectedCorrectedCorrectedCorrectedCorrectedRemovedRemovedReplacedRemovedRemovedRemovedRemovedRemovedRemovedCorrectedRemovedCorrectedCorrectedCorrectedCorrectedCorrectedCorrectedReplaced
ReplacedReplacedCorrectedCorrectedRemoved
Removed
Page 1 of 1
FORM '/2-ADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1440
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner -
76 South
2. Plant
F.E.N.O.C.(NAME)
Main Street - Akron, OH 44308
Date
Sheet
06/17/2005
I of_ 2(ADDRESS)
Beaver Valley Power Station Unit No. 2(NAME)
Route 168 - Shiopingport, PA 15077(ADDRESS)
3. Work Performed By BV-Maintenance(NAME)
Rt. 168 - ShiPpinaport, PA 15077
Order #200021177Repair/Replacemenl Orgarizaton P.O. No., Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Reactor Coolant (Class 1)
5. (a) Applicable Construction Code Section III 1977 Edition, S79 Addenda, -Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Correoted. ASMERemoved. Code
Name of Name or Manufacturer National Board Other Year or StampedComponent Manufacturer Serial No. No. Identification Btilt Installed (Yes or No)
Power Relief Valve Garret Pneumatic P-122 N/A 2RCS-PCV455C 1983 Corrected Yes
Plug Anderson N96012-76-01 N/A N/A 2004 Installed YesGreenwood Crosby
7. Description of Work Replaced valve plug.
8. Tests Conducted: Hydrostatic* E Pneumatic E: Nominal Operating Pressure El Exempt 3
Other E . Pressure psi Test Temp. ___ OF
'Record test pressure and temperature
LEJU
FORPM Y2-ADNI-080I.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1332, 1043, 800. 553, 361, and 088. Last two digits ofApplicable Manufacturer's Data Reports to be attached
-erial niimhbr of new npluo were not rmcordrd-nnr N-? rpoort was either 48 or 51.- ..- _-__ _-_ -. � --- -_ --- - � - ---- -- .- - - - ..
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signe I 6 r
Expiration Date N/A
S-/I 1-1 - Date June 28 20 05Owner or Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /0 -//- 03 to 5t- A 7-0 J-, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
jA__o-1J Z�_/ Commissions4z or's signature aNational Boafd. State. Promince. arId Endcrsenwots
Date 7__ ____ . 20 0S
Q.C.-392Sheet I of 2
FORM N-2 CERTJCAIE HOLDERS' DATA REPORT FOR IDENTICAL
NUCLEAR PARTS AND APPURTENANCES* .
As required by the Provisions of the ASME Code, Section III, Division 1:- Not to Exceed One Day's Production _
o * r __ __ fl _ _ _ .
1. Manutactured and certifed by Anderson Greenwood Crosby, 43 Kendrick St., Wrentharm, MA 02093-
(Name and Address of N Certificate Holder)FIRST ENERGY CORP.
2. Manufactured for(Name and Address of Purchaser or Owner)
BEAVER VALLEY POWER STATION3. Location of Installation
(Name and Address)
4. Type DS-C-67970-13REV.J ASME SA479 TYPE316 75,000 - 2004
(drawing no.) . (mat'l. spec. no.) (tensile strength) (CRN) (year built)
5. -. ASME Code, Section m, Division 1: 1977 SUMMER 1979 1 _
(edition) (addenda date) (class) (Code Case No.)
6. Fabricated in accordance with Const. Spec. (Div. 2 only) - Revision - Date
(no.)
7. Remarks1. .
8.9.
Nom. thickness (in.) - Mn. design thickness (in.) - Dia. ID (ft & in.) - Length overall (ft & in.)___
When applicable, Certificate Holders' data renorts are attached for each item of this report.I
I
-Part or AppurtenanceSerial Number
NationalBoard No.
in Numerical Order
(13(2,(3)(4)(5)(6)(7)(8)(9)(IC(11(12(13(14(15(16(17
(19,(20'(21;(22'(23)(24)(25)
) N96012-75-0148) N96012-76-0151II
I-
1) )_)_
A))-))
(2(2(2(2(3
(3:(3:(32(3'-(34
(3,(31(35(4((41(4Z(42(44(4!(47
'(41(48(49(50
Part or AppurtenanceSerial Number
L6).7) .L8)9)0)1) 12)3)4)5)
7)3)
7)1)
3)-4)S) -__
NationalBoard No.
in Numerical Order
Ir
i,
IIII.
10.Design pressure - psi. Temp. - 0 F Hydro. test pressure 6125 at temp. 70
(when applicable)
I Supplemenral information in th form of lists. sketches, or drawings may be used provided (1) ats' is 8-M2 X 11 (2) informawon in ice=r 2 and 3 on this Dam Repon
is inrluded on emen shee. (3) each shect is =rmbreiand the Hebcr of shet Es rcorded a the top of this form.
- ltis form (E000403 may be obtained from dhe Order Dept., ASME, 22 Law Drive, Box 2300, Fairfield. NJ 07007.2300
I-.
Q.C.-392Sheet 2 of 2Form N-2 (Back)
Certificate Holder's Serial No. N96012-75-0148 & 76-0151
CERTIFICATE OF DESIGN
Design specifications certified by LIKE EZEKOYE P.E. State PA Reg. no. 18379-E(when applicable)
Design report* certified by W. 0. GREENLAW P.E. State MA Reg. no. 14784(when applicable)
CERTIFICATE OF COMPLMNCE
We certify that the statements made in this report are correct and that this (these) Plugsconforms to the rules of construction of the ASME Code, Section III, Division 1.
NPT Ceriiflcate of Authorization No. N-1877 Expires Sep. 30, 2004Anderson Greenwood Crosby
Date 17 ? Jitl-oct Signed Wrentham, MA by > .c .(NPT Certificate Holder) (Authorized kpresentative)
CERTIFICATE OF INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andthe State or Province of 7 c.. ., and employed by ABS Group Inc.of Houston. Texas have inspected these items described in this Data Report on
I 6-~7-, 20 o and state that to the best of my knowledge and belief, the Certificate Holderhas fabricated these parts or appurtenances in accordance with the ASME Code, Section m, Division 1. Each part listed hasbeen authorized for stamping on the date shown above.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningthe equipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in anymanner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date - 20 LZ_.
SignedK (Authorized Inspector)
Commissions e. c teG(Nat'l. Bd. (inc. endorsements) and sate or prov. and no.)
FORM V.4-ADM-0801.F02 REV 2 RTL #o A4.4 14-A
Form No. 1563
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C. Date 07-05-2005(NAME)
76 South Main Street - Akron, OH 44308 Sheet 1 of 2(ADDRESS)
Beaver Valley Power Station2. Planit Unit No. 2(NAME)
Route 168 - Shippincport, PA 15077(ADDRESS)
3. Work Performed By BVPS - Maintenance(NAME)
Rt. 168 - Shippingport, PA 15077(ADDRESS)
Order #200016534RepairfReplacemrent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, S73 Addenda, - Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xi Code Case(s): N-416-1
6. Identification of Components
Correctedl, ASMERemoved, Code
Namnn of Name of Manufacwurer National Board Other Year or StarriedComrrponent Manuftcturer Serial No. No. Identification Built Inrtawed (Yes pr No)
Ball Valve Anchor Darling EZ776-6-2 N/A 2SWS-692 1996 Removed Yes
Body Flowserve N/A N/A Ht. #514082 2001 Installed No
Ball Flowserve N/A N/A Ht. #V78 2001 Installed No
7. Description of Work Replaced valve body. ball, and fasteners.
8. Tests Conducted: Hydrostatic* a Pneumatic* 0 Nominal Operating Pressure lI Exempt EOther E Pressure psi Test Temp. IF
*Record test pressure and temperature
LAL
FORM '/2-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Previous NIS-2 Data Report No. 934. New bodV. ball andApplicable Manufacturers Data Reports to be attacted
fasteners were removed from spare valve S/N E213T-1-1.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A Expiration Date N/A
Signed e 2 .. O 0$2/J1/OA 5,pa /lr Date JulV 14 , 20 05- (owner or Owners Designee, Title i
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT ofHartford. CT have inspected the components described in this
Owner's Report during the period 1O-// - ° to '-A 72- 5O and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
Inspet SgnatureCommissions K = A1 XI? Tg5
Nabbnal Board. State. Province. and Endorsements
Date 27-04, 20 0 5-
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES'As Required by the Provisions of the ASME Code, Section 1II, Division 1
Pg. lof
Flowserve Corporation
1. Manufactured and certified by 701 First Street, WilliamsDort, PA 17701-iname and address of N Certificate Holder)
2. Manufacturedfor First Energy Corp., P.O. Box 345, Shippingport, PA 15077Iname and address of Purchaser or Ownerl
3. Locationofinstallation Beaver Valley Station, State Rte. $168, Shippingport, PA 15077(name and address)
4. ModeiNo..SeriesNo..orType Ball DrawingW9624706 Rev. - CRN N/A
5. ASME Code. Section Ill. Division 1: 1971 S'73 2 V/A(edition) (addenda dater Iclass) (Code Case no.)
6. Pump or valve Valve Nominal inlet size 1 1/2" Outlet size 1 1/2"End (min.) in.)Piece Ball S13B
7. Material: Body SA479-304 ZKYNX SA479-304 Siz SA479-304 Bolting SA193-B8SA194-8
A (a)Cert.
Holder's
Serial No.
F? I 4r- I -.1
(bl* - Nat'l
Board
No.
N/A _
(ciBody
.Serial
No.
Et. $514082
(d)
End ==Piece Serial
No.
Ht.-gK0676
(e)
Ball X¢XSerialNo.
Et. V78
'Supplemental information in form of lists. sketches. or drawings may be used provided (1) size is bKY x 11. (2i information In items 1 through 4
on this Data Report Is Included on each sheet. 13) each sheet is numbered and the number of sheets Is recorded at the top of this form.
112)86) This form (E00037) may be obtained from the Order Dept. ASME. 22 Law Drive, Box 2300. Fairfield, NJ 07007-2300.
FORM NPV-1 (back)
8. Remarks
5.0. E213T-1
9. Design conditions 275 psi 100 - F or valve pressure class 15(1(pressurel (temperature)
10. Cold working pressure 275 psi at 1 00f
11. Hydrostatic test 425 psi. Disk differential test pressure 303 psi
CERTIFICATION OF DESIGN
Design Specification certified by F.W. Gardner P.E. State PA Reg. no.O3 6 6 1 4-EDesign Report certified by N/A P.E. State Reg. no.
Dei nR p r.crii db / P. E S aeR g o
I
CERTIFICATE OF SHOP COMPUANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code. Section i, Division 1.N Certificate of Authorization No N1712 Expires 4/15/01
Dates 121 3 101 'Iame Flowserve Corporation 'Signed t9 & *'fl1'Y tIN Certificate Holder) l authorized representative)
CERTIFICATE OF SHOP INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andtheState YAXjAeof - rDiny1yvn;i A andemployedbyCoMnerciat Union -TTn. Co.of S_ _ _ _ __n, MA have inspected the pump, or valve, described in this Data Report on
t - e+9.. ), and state that to the best of my knowledge and belief, the Certificate Holder. hasconstructed this pump, or valve, in accordance with the ASME Code, Section 1II, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning thecomponent described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any maeryfany personal injury or property or Ss of kind arising from'or connected with this inspection. -( !Jy
Date A-- ~ ig y s < X /o m si n Pennsv~vania 239225- h 1 ~ihoze onpelorl ( Nat'l. 8d. findl. andorsamentsi state or prov. and no.1
(1) For manually operated valves only.
I'
FORM VIrADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1618
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C. Date 07-08-2005(NAME)
76 South Main Street - Akron. OH 44308 Sheet 1 of. 1(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shinninonort- PA 15077 Order #200016001(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Rt. 168 - Shippingport, PA 15077(ADDRESS)
Repair/Replacement Organization P.O. No., Jobt No.. etc.
Type Code Symbol Stamp N/A
Authorization No. NIA
Expiration Date N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, S72Addenda, - Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components
corrected. ASMERemroved. Code
Nane of Nuam of Manufacturer National Board Otter Year or StampedCornponent M anufacturer Scrial No. No. Identification Built Installed (Yes or No)
Gate Valve Velan 1471 N/A 2SWS-481 1983 Removed Yes
7. Description of Work Removed valve from system and installed nevw section of pipe upstream of
2SWS-486.
8. Tests Conducted: Hydrostatic* Ea Pneumatic* n Nominal Operating Pressure A Exempt EOther El Pressure psi Test Temp. _ _ OF
'Record test pressure and temperature
FORM '/2-ADM-080I.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report No. 1233. New 3": Pipe Ht. #A41651, Flange Ht. #A22/2.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp. N/A
20 05L
Certificate of Authorization No. N/A
SignedDate 6 r
Expiration Date N/A
-lower,, Date -3-Ld 8Owner or Owner's Designee, Title "
CERTIFICATE OF INSERVICE INSPECTION
1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period / - i^ - 03 to 4 -A? 7- 04 and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
A-9 / 241AJ Commissions A:-, AJ,lnspiv Signature National Bdard. State. Province. and Endcrsements
Date , 20 Amf
Date .20 �
FORM W/2-ADM-0801.F02 REV 2 RTL K A4.414-A
Form No. 1620
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C. Date 07/01/2005(NAME)
76 South Main Street - Akron, OH 44308(ADDRESS)
Sheet I of I
2. Plant Beaver Valley Power Station(NAME)
Route 168 - Shinninonort- PA 15077
Unit No. 2
(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Route 168 - Shippincport, PA 15077(ADDRESS)
Order #20001 6048Repair/Replacemnent Organizatort P.O. No., Job No, etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, S72 Addenda. -Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/ReplacementActivity 1989
(c) Applicable Section XI Code Case(s): N-416-1
6. Identification of Components
Corrected, ASMSERenoved, code
Narme of Name of 1anufactuner National Board Other Year or StanpedCoirponent Manufacturer Serial No. No. Identificuen Built Installed (Yes or No)
Gate Valve Walworth D-69757 1948 2SWS-483 1979 Removed Ye
7. Description of Work Removed valve from system and installed new section of pipe upstream of
2SWS-488.
8. Tests Conducted: Hydrostatic* M Pneumatic* M Nominal Operating Pressure ED Exempt [l
Other E Pressure psi Test Temp. OF
'Record lest pressure and lesiperature
_ _ _ _ - IIlu
FORMv Vi-ADM-080l.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report No. 1207. New pipe Ht. #41651, new flange Ht. #3M40774.Applicable Manufacturer's Data Repots to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp NIA
Certificate of A thIiza tNo. N/A
Signed __
Expiration Date
'a 5Date
N/A
July 1 20 05- %- Owne76r Owner's Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period /0 - f/ 0 3 to Y" 7- 0x5, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
lns s SignatureCommissions Na #/, / ° ' gy
Nalons Board. State. Prornice, and Endorsernents
Date 7- -- ., 20 °Or
FORM V2-ADM-080l.F02 REV 2 , RTL N A4.414-A
Form No. 1663
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date 06/15/2005
Sheet I of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippingport, PA 15077 Order #200014878
3. Work Performed
Rt. 1
(ADDRESS) RepairJReptarement Orgariz2fiOn P.O. No.. Jcb No- etc.
By BV-Maintenance Type Code Symbol Stamp N/A(NAME)
68 - Shipcingport. PA 15077 Authorization No. N/A(ADDRESS)
Expiration Date N/A
4. Identification of System Chemical and Volume Control (Class 2)
5. (a) Applicable Construction Code Section III 1971 Edition, W'72 Addenda, 1649 Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Correcied. ASMRemoved. Code
Name of Name of Manufietwer Natial Board Otber Year or StampedComponent Manufacturer Serial No. No. I-.denificasion Built Installed (Yes or No)
Relief Valve Crosby N67968-00- l 1038 2CHS-RV257 i985 Removed Yes
Relief Valve Andeon N67968-01-0004 N/A 2CHS-RV257 2003 Installed YesGreenwood Crosby
7. Description of Work Replaced valve with spare.
8. Tests Conducted: Hydrostatic* R Pneumatic* E] Nominal Operating Pressure A Exempt EOther El Pressure _ _ psi Test Temp. OF
*Record lest pressure and temperature
FORM W/-ADIN-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Replaced valve with spare for testing purposes.Aplicabte Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authori tQ 5 No.
Signe d S
NIA Expiration Date N/A
:swi, ,i 0 ;r Date July 12 1 20 05v- Owner or Owner's Designee. Titte
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in thisOwner's Report during the period ° L// 0 .3 to e 7-0 . and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
In pcor's SignatureCommissions t ./L/ Off r3
Nat&inal Board. State. Provinces and Endorsements
Date ., 20 0 rDae2 .
Q.C.-44C-1Sheet I of 2
FORM NY-1 FOR SAFETY AND SAFETY RELIEF VALVESAs required by the Provisions of the ASME Code Rules
DATA REPORT
1. Manufactured By - - Anderson Greenwood Crosby, 43 Kendrick St., Wrentham. MA 02093Name and Address
Model No. 7R-TDrs TypI Order No. U727430000 Contract Date .37805 National Board No.
2. Manufactured For FIRST ENERGY CORP. Order No. 45101067 CO REV.1Name and Address
3. Owner FIRST ENERGY CORP.Name and Address
4. Location of Plant BEAVER VALLEY
5. Valve Identification BV-2CHS-257 Serial No. N67968-01-0004 Drawing No. DS-C-67968-1 REV. -
Type SAFETY RELIEF Orifice Size 2.030 Pipe Size -Inlet 3 Outlet 4Safety, Safety Relief, Pilot, Power Actuated Inch Inch Inch
6. Set Pressure (PSIG) 70 130Rated Temperature
Stamped Capacity 579 GPM WATER70DEGS @ 10 % Overpressure_- Blowdown (psig) 10% of S.P.
Hydrostatic Test (PSIG) .Inlet 425 Complete Valve 425
7. The material, design, construction and workmanship comply with ASME Code, Section III.
Class 2 Edition 1971 Addenda Date 'WINTER 1972. Case No. 1649
Pressure Containing or Pressure Retaining Components
a. Castings
Body
Bonnet
b.Bar Stock and Forgings
Support Rods
Nozzle
Disc Insert
Spring Washers
Adjusting Bolt
Spindle
Serial No.
Identification
N94701-33-0005
N94704-32-0004
N90158-70-0106
N94702-32-0005
N88697-50-0299
N88697-50-0300
N88698-77-0242
N88700-30-0194
Material Specification .-
: - -Including Type or Grade
ASME SA351 GR.CF8M
ASME SA216 GR.WCB
ASME SA479 TYPE .316
ASME SA479 TYPE 316
ASME A193 GR.B6
ASME SA193 GR.B6
ASME SA193 GR.B6 ,
al / .(
I IN I
Q.C.-44'-1Sheet 2 of 2Form NV-I (Back) Certificate Holder's Serial No. N67968-01-0004
Serial No.Identification
NX3051-0042
Material SpecificationIncluding Type or Grade
ASTM A313 TYPE 316c. Spring
d. Bolting
e. Other Parts such as Pilot Components
Disc Ring N94703-33-0008 ASME SA479 TYPE 316
Bonnet Stud N96125 ASME SA453 GR.660
Bonnet Stud Nut N95997 ASME SA193 GR.B6
We certify that the statements made in this report are correct.Anderson Greenwood Crosby
Date 4id 20 03 Signed Wrenrham. MA By T . C- tbManufacturer
Certificate of Authorization No. N-1878 Expires Sep. 30, 2004Date
f _ _ _ ___ _ ~~~~~~._______.______ I
CERTIFICATE OF SHOP INSPECTlOV
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and theState e fAmi~a of MA and employed by
ABS Group Inc., Houston, Texashave inspected the equipment described in this Data Report. on
/a _- - 2003 and state that to the best of myknowledge and belief, the Manufacturer has constructed this equipment in accordance with the applicableSubsections of ASME Section III.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied,concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from orconnected with this inspection.
Date 20 03,. v
(National Board, State, Province and No.)
/ 1 -
- -
FORM Y2-ADM-0801.F02 REV 2 RTL # A4.414-A
Form No. 1670
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date
Sheet
12/2012004
1 of 2
2. Plant
(ADDRESS)
Beaver Valley Power Station(NAME)
Route 168 - ShiDpincport, PA 15077
Unit No. 2
(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Route 168 - Shiopinaport. PA 15077
Order 9200067892RepairlReplacerment Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda, N/A Code Case
-(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components
Corrected. AkSMERermoved. Code
Name of Name of Manufacturer National Board Other Year or StampedComponent Manufacturer Serial No. No. Identification Built Installed (Yes or No)
Ball Valve Anchor Darling EZ913-1-1 N/A 2SWS-1272 1997 Installed Yes
7. Description of Work 'Added a' new Valve to system.
8. Tests Conducted: . Hydrostatic* E Pneumatic* Ea Nominal Operating Pressure 13 Exempt ElOther El Pressure psi Test Temp. OF
Record test pressure and temperature
.
FORM Yi-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Pipe nipple, 2" NPS, Ht. #9711 H also added to system.Applicaule Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp. N/A
Certificate of Authorization No. N/A
Sinner!d 6 /32 S.1r
Expiration Date
J 1l Date
N/A
Spes July 8 20 05- t * __ > w -r--
- - Owner or Owneras Designee, Title
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT ofHartford, CT have inspected the components described in this
Owner'sReportduringtheperiod /0 -° / ° 03 to O'-,A P- 0r ,andstatethattothe
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
_ RCommissionsInspect gnature National 1oard. State, Province, and Endorsements
Date ., 20 05-_Date .20 0.5
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES'As Required by the Provisions of the ASME Code, Section Ill, Division 1
Pg. of
1. Manufacuredandcertifiedby Anchor/Darling Valve Co., 701 First St., Williamsport, PA 17701Inam and address of N Certificat Holder)
2. Manufacturedfor Duquesne Light-Co., P.O. Box 347, Shippingport, PA 15077-0347(nme and addss of Purchar or Owner)
3. Locaionof installation Beaver Valley Station, State Rt. 168, Shippingport, PA 15077Inamn and address
4. Model No.. Series No., orType Ball Wrewing W9624702 Rev A CRN --
5. ASMS Code. Section 111, Division 1: 197.1 Summer 1973 2 __-editioni (addends del I(desal - (Code Cas, no.)
6. Pump or valve Valve Nominalinletsiz- 2 Outlet size 2"(in.) ' In
7. Material: Body SA479-304 xg&-Ax. SA479-304 Zr SA479-304 Bo0ting SA193-B8-1
End Pi~ece Ball SA194-8* (a)Cart.
Holder'sSerial No.
EZ913-1-1
Ib)Nat'l
BoardNo.
N/A
. I
(ciBody
- Serial
No.-
Heat #513025
Idl (a)
3esmt End Piece D0Nx BallSerial - Serial
No. No.
Heat #V17 Heat #514082
.
* 1 - ; . ;,
. . .
. .
. . .
* Supplsmental information In form of lists. skatches. or drawings may be used provided (11 size Is 8 K x 11 l21 (information in Items 1 through 4on this Data Report Is Included on each sheet. 13) each sheet is numbered and the number of sheets Is recorded at the top of this form.
(12188) This form IE00037) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. SJ 07007.2300.
FORM NPV-1 (back)
8. Remarks 2"-150#-Ball Valve Full Port w/9" Lever
9. Design conditions 275 psi 100 °F or valve pressure class 150fpressureI . tteffpe(Utel
10. Cold working pressure 275 psi at 1000F
11. Hydrostatictest 425 pil. Disk differential test pressure 303 psi
CcE zMFICATION OF DESIGN
Design Speeifiesialon certified by F. W. Gardner P.& Se P e.n. 036614-E
DesignReportcartirtedby- N/A PXr State Reg. no.
I - ICERTIFICATE OF SHOP COMPLIANCE
We certify that the statements made iri this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code. Section Ill. Division 1.N Certificate of Authorization No N1712 Expires 4/15/98
Date2J2519 7 M.me Anchor/Darling Valve Comnanigned(N Cartficate Howderi twind.0 ruorw~ntatiV4l
CERTIFICATE OF SHOP INSPECTION
1. the undersigned, holding a valid commission-issued by the National Board of Boiler and Pressure Vessel Inspectors andtheState xcxxcx=6of Pennsylvania andemployedbyColmiercial Union Ins. Co.of Stn. Mass. have inspected the pump. or valve,. described in this Oata Report on
;l m L5 919 9 2. and se that to the best of my knowledge and belief, the Certificate Holder hasconstructed this pump. or valve, in accordance with the ASME Code. Section Ill, Division 1.
By signing this certificate, neither the inspector not his employer makes any warranty, expressed or implied. concerning thecomponent described in this Oats Report. Furthermore, neither the inspector nor his employer shall be liable in any manner forany personal injury or property damage o"los of any kind arising from or connected with this inspection.
Oats am!L 9 ~ g tCommissions Pennsylvania 2392Ch T vTz IN¢I. 8d. rnmd. .ndorsmoertl ste of Prov. and no.1
81 or m nu U o e at d. 7v s n Y
I
I 1 For manually operated valves only.
FORM 'A-ADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1679
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME):
76 South Main Street - Akron, OH 44308
Date 12/20/2004
Sheet ' 1 of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippincport, PA 15077(ADORESS)
3. Work Performed By Anderson Greenwood Crosby(NAME)
43 Kendrick St.-Wrentham, MA 02093
Order #200072791pRepairlReplacement Orgarizaoion P.O. No.. Job No, etc.
Type Code Symbol Stamp I N/A
Authorization No. - N/A(ADDRESS)
Expiration Date N/A
4. Identification of System Reactor Coolant (Class 1)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda. N/A Code Case
(b) Applicable Edition of Section Xl Ublized for Repair/Replacerment Activity 1989
(c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components
Corrected. 45M61Re~moved COdeNane of Name or Manufacturer National Board Other Year or Stanfvcd
Conronent Manufacturer Serial No. No dentticahtion Built Installed (Yes or No)
Safety Valve. Crosby N56963-00-0011 N/N 2RCS-RV551C 1985 Corrected Yes(Spar-)
Disc Insert Anderson N90349-29-038 N/A Ht U 1810-1-1029 2003 Installed YesGreenwood Crosby
Spindle Assy. Crosby K56381-80-0195 N/A N/A 1988 Installed No
7. Description of Work Replaced spindle assemble and disc insert.
8. Tests Conducted: Hydrostatic* [ Pneumatic* [ Nominal Operating Pressure E Exempt Z
Other Ea Pressure psi Test Temp. OF .
'Record test pressuxe and tetrperature
_ _ _L EJ1
FORN I'/-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Previous NIS-2 Data Report Nos: 1532, 1474. 979. 556. 345.Appticabte Manufacturer's Data Reports to be attached
205. 123 014. and 010. Valve will be Svstpm L[Rakana tested when installed into the qvtem.
Work was performed by Anderson Greenwood Crosby at Wyle Labs under the FENOC QA
Program. Last digit of the serial number of disc insert was not recorded.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorization No.
Signed _ A
N/A Expiration Date N/A
:!&u1;r- e-PWrJ4 lir Date January 18 20 05Owner or Owneres Designee. Title I
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period IL-/ to / -/ f - SJ' ,and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
"O' , - /. L; t , �'/ Commissions Ntoa id. Stat./ P a rSemnNational Board. State. Prorince, and Endorsementslns:;9'gnature
Date /-/ 7- , 20 s-
Q.C.-392Sheet I of 2
FORM N-2 CERTIFICATE HIOLDERS' DATA REPORT FOR IDENTICAL-.NUCLEAR PARTS AND, APPURTENANCES*
As required bv the Provisions of the ASME Code, SectionIll. Division I - Not to Exceed One Day's Production-
1. Manufactured and certified by
2. Manufactured for
Anderson Greenwood Crosby, 43 Kendrick St.. Wrentham, MA 02093* (Name and Address of N Certificate Holder)
FIRST ENERGY CORP.
I3. Location of Installation
(Name and Address of Purchaser or Owner)BEAVER .VALLEY POWER STATION
(Name and Address)4. Type DS-C-56963 REV. D STELLITE NO. 6B ' N/A -- 2003
- (drawing nso.) (mat'l. spec. no.)' (tensile strength) (CRN) (year built)5. ASME Code, Section 111, Division 1: 1971 ' WINTER 1972 1
(edition) (addenda date) (class) (Code Case No.)6. Fabricated in accordance with Const. Spec. (Div. 2 only) ' - Revision - Date --
'*(no.)7. Remarks ' . .
8. Nom. thickness (in.) --_Min. design thickness (in.) '-- DE-:1D (ft & in.) Length overall (ft & in.)9. When applicable. Certificate Holders' data reports are attached for each item of this report.
Part or AppurtenancePart or Appurtenance
Serial Number
'N90349-29-0383(1)(2)(3)(4)(5)(6)(7)(8)(9)
* (10(it(12(13(14(15(16(17(18(19.(20,(21,(22(23:(24:(25
N90349-29-0385-
:
)-!))-)
i)_')
,).
National - Part or AppurtenanceBoard No. ' Serial Number
in Numerical Order._____--__ (26)
_ __ ._ .:_-_ . (27)* . _ _ _ (28)
.(2.-______ _ .. :. (30 '~
- I{. <'(33)*__ _ __ -"(34) s
(35) :_ _ _ _ _ (36)
: (37)(38)
*_ (39)(40)..
* (41)*_ (42)..___ . (43)
_.....___ (44)-
______:___ (45).
A.__ . (447)
_ (48) -.._ (49)
a: (50)
NationalBoard No.
in Numerical Order
)-
--- I I.
.- s..
10. Design pressure -- psi. Temp. - 0 F Hydr`. test pressure 4575 at temp. 70 0 F
(when applicable)Supplemental information in the form of lists. sketches, or drawings may be used provided (1) size is S-?2 x Ill. (2) information in items 2 and 3 on this Data Report
is included on each sheet. (3) each sheet is numbered and die number of shects is recorded ax thecoj o( this form.
This form (E00040) may be obtained from the Order Dept.. ASS E. 22 Law Drive. Box 2300, Fairfield, NJ 07007-2300
- ~ ~ I AE
Q.C.-392Sheet 2 of 2Forn N-2 (Back)
Certificate Holder's Serial No. N90349-29-0383
CERTIFICATE OF DESIGN
Design specifications certified by F. KENNETH DELUSE P.E. State PA Reg. no. 17128-E(when applicable)..,.
Design report* certified by W.D. GREENLAW P.E. State MA Reg. no. 14784(when applicable)
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are'correct and that this (these) Disc Insertsconforms to the rules of construction of the ASME Code, Section lII, Division 1.
NPT Certificate of Authorization No. N-1877 'Expires 'Sep3.io3 2004Anderson Greenwood Crosby.
Date S Signed Wrentha'rfi, MA'- by D. _ 2,t(NPT Certificate HodIer)' (AuthorizedRWepresentative)
CERTIFICATE OFlJNSPECTION
1, the undersigned, holding a valid commission issued by ,the Nationaj.Board of Boiler and Pressure Vessel Inspectors andthe State or Province of Massachusetts and employed by %ABS Group Mc.of Houston. Texas have inspected these items described in this Data Report.on
, 20 _ and state that'to the best of *nyAknowledge and belief, the Certificate Holderhas fabricated these parts or appurtenances in accordance with the ASIAE Code, Section 111, Division 1. Each part listed hasbeen authorized for stamping on the date shown above. i., , I' -.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerningthe equipment described.in this Data Report. Furthermore, neither the Iispector nor his employer shall be liable in anymanner for any personal injury or property damage or losses of any: kind arising from or connected with this inspection.
Date A 0 >;) 3 , 2003
Signed ,,9 , I-(Authorized Inspector .).
Commissions N -/ A '-9 7 2.I.dv.(Nat'l. Bd. (incl. endorsements) and state or prov. and no.)
�.T -
. . . 1�1.'
. .. .1.*. .:i*
1.i
-
FORM V2-ADlM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1680
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date 12/20/2004
Sheet I of 2(ADDRESS)
Beaver Vallev Power Station2. Plant Unit No. 2(NAME)
Route 168 - ShirningportP PA 15077 Order #200014967
3. Work Performed
Rout
(ADDRESS) RepairlReplacement Organization P.O. No.. Job No.. etc.
By BVPS-Maintenance Type Code Symbol Stamp N/A(NAME)
te 168 - Shippingport, PA 15077 Authorization No. N/A(ADDRESS)
Expiration Date N/A
:
4. Identification of System Component Cooling-Primarv (Class 3)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, NIA Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Actvity. 1989
(c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components
Corrected. ASMEResoved, Code
Najse of Name of Mmnufacturmr National Board Other Year or StaipedComponent Manufacturer Serial No. No. Identification Built Installed (Yes or No)
Check Valve Mission B5381 N/A 2CCP-5 1976 Removed Yes
Check Valve Crane Nuclear Dl 172 N/A 2CCP-5 2003 Installed Yes
7. Description of Work Replaced valve with spare.
8. Tests Conducted: Hydrostatic' al Pneumatic* a Nominal Operating Pressure 1 Exempt ElOther E Pressure psi Test Temp. ___ OF
Record test pressure and temperature
-_ _ - - li
FORM /2-ADNI-080L.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Reoort attached.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed Ju 1 2 05-Da
Expiration Date N/A
- 5agE21. /<ar Date July 1 20 05-%. Owner or Owner's Designee, Title
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period / -_ v o< 3a to / 2- 0 51 , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with
this inspection.
-nspy -/ Commissions a, /°" 3nsp, Signature National Board. State. Province, and Endorsements
Date 7 -= - , 20
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section 1II, Division 1
Pg.I of 2
1. Manufactured and certified by CRANE Nuclear. Inc.. 860 Remington Boulevard, Bolingbrook. IL 60440(name acid address of NPT Certificate Holder)
2. Manufactured for First Energy Corporation, PO Box 345 Shippingport. PA 15077(nam 1 and address of purchaser)
3. Location of installation Long Term Storage Facility. Shippingport Hill Road. Shippingport, PA 15077(name and address)
4. Model No.. Series No.. or Type DOO-M1291-00 Drawing CB02778 Rev. C CRN N/A
5. ASME Code. Section 1II, Division 1: 1974 Summer 1974 * 3 N/A(edition) (addenda date) (dais) (Code Case no.;
6. Pump or valve 'Duo-Chek Valve Nominal inlet size 20 Outlet size 20
7. Material:
(a) valve Body SA351 CF3M Bonnet NIA Disk SA351 CF3M Bolting SA479 TP 316A(b) pump Casting Cover Bolting
(a) (b) (c; (d) (e)Cert. Nat'l Body/Casing Bonnet/Cover Disk
Holder's Board Serial Serial SerialSerial No. No. No. No. No.
D1172 N/A D1174 N/A 01176,D1177D1173 N/A 01175 NM - 01178 01179
Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 8 Y, x II. (2) information in items 1 through 4 on
this Data Peport is included on each sheet. (3) each sheet is numbered and the nujmter ofsheets is recorded at the top of this form.
This form (E100037) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007-2300.
- l -iU
FORM NPV-1 (Back) -- Pg. 2 of 2
Certificate Holder's Serial No. D1172 & 01173
8 Design conditions psi(pressure (temperature)
'F or valve pressure class ANSI 150 (1)
9. Cold working pressure 275 psi at 100-F
rIk 1,8t
10. Hydrostatic test 425 psi. Disk differential tePo No. 710t570, Rev. 1
11. Remarks: P4o-4,. ,74 _ _1F Item No. 1 SO No. 20653-01Mark No.: Valve ID: VC1015-C-3
st pressure 305 psi
CERTIFICATION OF DESIGN
Design Specifications certified by Walter Joseph Parker. Jr. P.E. State PA Reg. no. 29003-E
Design Report certified by NIA P.E. State N/A Reg. no. N/A
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code. Section 111. Division 1.
N Certificate of Authorization No. N-2899
Date 01/27/03 Name CRANE Nuclear. Inc.(N Cendcate Hokleri
Expires September 24. 2005
Signed ( z _ ,4 7 autJom A .Kuro sk.v e .
Jerome A. Kurowski. P.E.
CERTIFICATE OF INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and theState or Province of Illinois and employed by HSBCTof Hartford, CT have inspected the pump, or valve, described in this Data Report on 01127103and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordancewith the ASME Code, Section Ill, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning thecomponent described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner forany personal injury or property damage or loss of any kind arising from or connected with this inspection.
Date 01/27/03 Signed , ommissions IL 1903(Nat 1. 8d. (ind. endorsements) and state or prov. and no )
. . _
(1) For manually operated valves only. /
FORM Y/-ADMN-080.F02 REV 2 RTL # A4.4 14-A
Form No. 1684
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl - I
1. Owner F.E.N.O.C. Date 12/20/2004(NAME)
76 South Main Street - Akron. OH 44308 Sheet 1 of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME?
Route 168 - Shinninaoort, PA 15077 Order #200021737(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Route 168 - Shinninaport. PA 15077
Repair/Replacenent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp NIA
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda, 1672 Code Case
(b) ' Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): NIA
6. Identification of Components
Corrected. ASMERemnoved, code
Naoe of Name or Manufacturer Kational Board Other Year StampedCopvosent Manufacturer Serial No. No. Identiiationk - Built Istalltd (Yes or No)
Globe Valve Walworth D-66443 . 1704 2SWS-150 1978 Corrected Yes
Disc Crane Nuclear D0049 N/A Ht. 400248 2001 Installed Yes
7. Description of Work Replaced valve plug and tack welded lock nut to pluq.
8. Tests Conducted: Hydrostatic* a Pneumatic* El Nominal Operating Pressure a Exempt 3
Other a Pressure psi Test Temp. OF
*Record test pressure and (eeyperature
FORM Y/2-ADM-0801.1F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached.Applicable Manutacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A
Signed
Expiration Date N/A
4\_6AZJ41/9- Date January 11 20 05O'mer or Owner's Designee. Title I
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT h inspected the components described in this
Owner's Report during the period 3to / -/ol / and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
_ Ins p Sgnature
Commissions X/ S ,t Y l YA 4 + MAnnational Board, State. Province. and Endorsements
Date 20 _ _ _ _
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section IIINot to Exceed One Day's Production Pg.1 of 2
- - - - - 7--
1.
2.
3.
4.
5.
6.
7.
Manufactured and certified by CRANE Nuclear. Inc., 860 Remington Boulevard. Bolingbrook, IL 60440(name and address 01 NPT Chrdfcato Holder
Manufactured for First Energy Corporation, PO Box 345. Shippingport, PA 15077(name antd address of purchaser)
Location of installation Beaver Valley Power Station, Route 168. PO Box 4. Shippingport, PA 15077( .me and address)
Type C-7875-7, Rev. B SA216 Gr. WCB 70 KSI (Min.) N/A 2001(drawing no.) (marl. spec. no.) (tensile strength) (cRN) (year built)
ASME Code, Section ill, Division 1: 1971 Summer 1972 3 N/A(edition) (addenda date) (dais) { (Code Case no.)
Fabricated in accordance with Const. Spec. (Div. 2 only) N/A Revision N/A Date N/A(no.)
Remarks: PO No. 7053232. 1, Item 1 SO No. 12611-01 3 Disc; PIN 653789, w/Stellite #6 Hardfacing
For a_3_5275WE,_150#._Globe Valve Assembly DrawingsNos._SK-1950-14,_Rev. G No Hydra performed
Material supplier PRL Industries, Inc.. Ht. No. 00248. PRL SIN: Ml 136-
8.
9.
Nom. thickness (in.) 0.875 Min. design thickness (in.) 0.50 Dia. ID (ft. & in.) 3.00W
When applicable. Certificate Holders' Data Reports are attached for each item of this report
Length overall (ft. & in.) 1.56
Part or Appurtenance NationalSerial Number Board No.
In Numerical Order
(1) 00049 NIA(2)(3) /(4) _
( 5 ) _ _ _ _ _ _ _ _ _ _ _ _ _ _
( 6 ) _ _ _ _ _ _ _ _ _ _ _ _ _ _
(7) /(8) /(9) /
(1 0)
(12) 7
(13) _
(14) /(15)(16)(17)(18) /_(19) /
(20)(21)(22)(23) _(24
H A ) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Part or Appurtenance NationalSerial Number Board No.
In Numerical Order
(26) /(27)(2 8 ) _ _ _ _ _ _ _ _ _ _ _ _
(2 9 ) _ _ _ _ _ _ _ _ _ _ _ _
(30)(31)(32) - _ - _-_ _
(33) _ _
(35) -_//(36) /(37)(38)(39)(40)(41)(42)(43) /(44)(45(46) /(47)(48)(49)( ________________________
10. Design pressure ANSI 150 psi. Temp. ANSI 150 'F. Hydra. test pressure *- at temp. 'F.(when applicable)
Supplemental Wormation in the form of fists sketcsei. or drawings may be used provided (I) size is 8 XA x 11. (2) information in itms 2 and 3 on this Data Report is included On eachsheet (3) each sheet is nunbered and the imnber of sheets is recorded at the top of thNs rm.
ThMs form (E000401 may be obtained rnm th1e Order Dept. ASUE. 22 Law Orive. Box 2300. Fairfield. NJ 07007-2300.
FORM N-2 (Back) -- Pg. 2 of 2
Certificate Holders Serial Nos. 00049 through N/A
CERTIFICATION OF DESIGN
Design specifications certified by Alan J. Fiorente P.E. State PA Reg. No. 032366-E(when aplIcabDe3
Design report * certified by N/A P.E. State N/A Reg. No. N/A(when appicabie)
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this (these) Disc - P/N 653789conforms to the rules of construction of the ASME Code, Section 111, Division 1.
NPT Certificate of Authorization No. N-2900 Expires September 24. 2002
Date 02128/01 Name CRANE Nuclear, Inc. Signed L(NPT Cenitdcate Holder) -TAutrod Representative)
Jerome A. Kurowski, P.E.Sr. QualIty Assarance Eigineer
CERTIFICATE OF INSPECTION
1. the undersigned. holding a valid commission issued by the National BSaid of Boiler and Pressure Vessel Inspectors and the State orProvince of Illinois and employed by Factory Mutual Insurance Company
Johnston, RI have inspected these items described in this Data Report on 02128101 , and state that to the,est of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code.Section Ill, Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipmentdescribed in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injuryor property damage or loss of any kind arising from or connected with this inspection.
Date Q. r'-4�wdgul--'A02128101 Signed Commissions Illinois 1077(NatiL d. (wni endorsements) and state or prov. and no)Autltxnred Nuclear inspector)I James Bush
1 ( -; !k.. oX. 038l.F02 REV 2 RTL #A4.414-A
Form No. 1692
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date 06/1512005
Sheet 1 of 1(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shinninonort, PA 15077 Order #200088962(ADDRESS)
3. Work Performed By BV-Maintenance(NAME)
Rt. 168 - Shippingport, PA 15077(ADDRESS)
Repair/Replacernent Organizabion P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Quench Spray (Class 2)
5. (a) Applicable Construction Code Section HIl 1980 Edition, S81 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Correctd. ASMERemmed. - Code
Nameof Name of Mamfaciusr'r National Boad Other Year or StmpedComponert Manuracrurer Serial No. No. Identificarion Buik Inst alled (Yes or No)
Globe Valve Target Rock 2 N/A 2QSS-SOVI02B 1985 Corrected Yes
7. Description of Work Tack welded bonnet to bodi.
8. Tests Conducted: Hydrostatic El Pneumatic* 5 Nominal Operating Pressure 5 Exempt ZOther E] Pressure psi Test Temp. OF
Record lest pressure and eomperature
FORM Y/2-ADNI-080I.F02 REV 2 RTL # A4.41J4-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Reoort No. 793. Tack welded bonnet to bode following disassemblyApprcable ktanufacturees Data Reports to be attached
for a maintenance inspection.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode. Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No. NIA
Signed GAP
Expiration Date N/A
- z1n11r-J4 /,_�7- Date June 16 20 05_. .,, _
1Tiwner or Owner's Designee. Title I
CERTIFICATE OF INSERVICE INSPECTION
i, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /0 °-// -0 ° to G - A 0 - 0-S and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificati neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
In' or's SignatureCommissions G ,/J, God ? r
National Board. Stale. Promnce. and Endorsements
Date 6 -.A 0 _ , 20°04
FORM V2-ADM-0801.F02 REV 2 RTL tt A4.4 14-A
Form No. 1695
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner -
76 South
2. Plant
F.E.N.O.C.(NAME)
Main Street - Akron. OH 44308
Date
Sheet
12/20/2004
1 of 2(ADDRESS)
Beaver Valley Power Station Unit No. 2(NAME)
Route 168 - Shippingport, PA 15077(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Route 168 - Shippingport, PA 15077(ADDRESS)
Order #200065869Repair/Replacement Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Fuel Pool Cooling (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, W72
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): N/A
6. Identification of Components
Addenda, N/A Code Case
Corrected,. ASMERemoived. Code
Name of Name of Manufacturer National Board Other Year or StampedComprorien Manufacturer Senal No. - No. Identification Built Installed (Yes or No)
Check Valve Walworth A1093 1084 2FNC-108 1978 Corrected Yes
7. Description of Work Replaced body/cover studs and nuts. '
8. Tests Conducted: Hydrostatic* E Pneumatic* U Nominal Operating Pressure El Exempt Z
Other E] Pressure psi Test Temp. _ _ OF
'Record test pressure and temperature
- _____wU
FORM Y/i-ADM-0801.F02 REV 2 RTL #A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Replaced 5/8" diameter body/cover: studs- Ht. #J544 andApplicable Manufacturers Data Reports to be attached
nuts- Ht. #STK and 721598 SVE.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed uly 5
Expiration Date N/A
br 6p" /Isr Date Julv 5 20 05%- Owner or Owner's Designee, Title
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT ofHartford. CT have inspected the components described in this
Owner's Report during the period o- /i I - 3 to 0_ & 7- °J , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
49Z..'r-, -.dp Commissions WY"4' I?'X? /d4 I; 'National Board, State, Province. and Endorsements)ppector's Signature
Date 7 - _.- 20 0S
FCR.M `iPV-1 NIAINUFACTURERS' DATA REPORT FOR NUCLEAR PU.MPS OR VALVES'(As Requirtd by the Provisions of the ASME Cade. Section M. Div. 1)
Sn -2 Z n C Z C; t C.-I
M stz:isn, Uniz-- Z CA Ncr-'rJ. cr nt ,I jl:%l cut1vt S 0
onc-Ill!a# Mccol No.. !bl Mjmu.,3c-.:t,!rs' !v Conician
mos No. Serial Revisirmic'n 1c) Drawing (qj Year.,
N O. No. te) C!4%3 8d. No. Built
1024'6103-
.4
Borated water -servicell;rw d"e-ription of Bore" foirwhith equipMent will des;9ned)
'150o AN.S1S. Des'.-;n Conditions PSI IF or Valye Prenurt Class
Yn fTomperaturt)Working Prerssure - F.Cold Ps"t I DV
S. Pressure Retaining plects
Jhrk No. Material Spec. No. Manufacturer SernarksJ. JU
O'Cartinps'B0,V SA-351 CF8 lqalwor:t:�hAl�qycci 3403D
C-O er SA-351-CF8' Walworth/Alovco 7297EA 5-75CSA-3 51' CER W;1 12vc Q
.Z
?keep:
7:
t-0 V;
7TN-si.*� f-.rrft;0 or-crawing- r1py be:Uted p-rovid d fit" 5.1,2'. y I�Jvrr7,xiiin
__ _- _ _ _ _
P%A 4 W.__* -
'CI ~OS~'cAI 'II
S t W - l as I SA-193. Gr.. BS :_3 _& G _-If. j_ ;I_ 3_ _I I
CZ : s-194. G-. 8 . B & G Mfcg. I S6INu:.
'i v.,, -
9. Hr
(d) Ohfer Parts: I
I______ I ______I _______
II I
! _1I I . ..
I . ,
I
. ;
. . .. t .
___________________ ____________________________ I. I.. .. . .
______________________ ________________________________ II __________________________ I _______________________
__________ _______________ .1 ____________ I ___________
*1* I *.. I.. .K..�;..._________________ I _________________________ I ____________________ __________________
Irortatic test 425 -Ps. ., , * -; - .
.' '' ', . t ..
.:'
CEMiFICATE OF COMPLIANCEi- .
We certdy that the sttemuents made in this report are correct and that this pump, or valve, conforms to the rules ofconrtmcton of the"ASME Code for Nuclear Power Plant Components. Section 1ii r.iv. L. Editlon ______
Adderda .ikl . 12 72 Code Case No. 1672 Date j e'.
sj;,4dWalworth Cornpanv/Alovco Plant
Our AS;MECesif iczt otAuthoriratlon No. N-2076 to us# the symbol 2xpires 4-7-81( .N) (NF) 10.)
.1 1.
i
CERTFICATION OF DESIGN.
~~ Walorth Comtnany/A1yco -PlantStjis snafy$le rport 1Ca= I oniyj on oai at'- Not emrd
Ot;n ;~d3C'~r etfe ytI Frank. A. Gooal~anips S~tat *-,Pa. .. RegNo._. 21966-E:.S~rese3iaftilyzii cmr~dflby (1) . o ei~FE State Reg. No. _ _ _ _ _ _ _
V1) Signature not required. List namne only.
CERTFiCATE OF SHOP INSPECTION -....*-;
I. le undersigned, holding a valid commission lszued by the National Board of Soiler and Prissure Vetstel Inspectors
3i<dthe S!azeP vi*rne!f New Jerse ind employed by HSBI&Z Co,cr aror , at . - have inspected the pump, of valve, described ln thits 0ata>Repcrt on
- L° 19 and state that to thol best of my ktnowtedge and belteftthe &Iarufacturtr has con.': ?c i;. p.p or valve, In ac ordance with the ASME Code, Section Ill.
.:. ': /i-n - !-t.2'. n'ither J.e In:pectoe nor his emnployer'makes any warranty, expressed or imiliedd ccnc'ni.',:,.'..- 4' t.:: - -- ' -'cr~bed in :h D Reort. furt arm r ncithci the Inspector nor his employer shall be lIabla Iny
.|W* .. ~ nure or tro;p.-r- dJmaig or a losa oi iny kind ariszng frorn or. conn ccd witlh hi: Insrecdcn,.TS
_ _ _* _i _ . _ _ _ _.- _ C o r n sTial 0.'' "" . -. : IN ~rt Bd.. S L t.. end 'o I -
:
FORM V/i-ADM-0801.F02 REV 2 RTL # A4.414-A
Form No. 1696
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner First Energy(NAMIE)
78 South Main Street. Akron. OH 44308
Date 06-06-05
Sheet 1 of 2(ADDRESS)
2. Plant Beaver Valley Power Station(NAMEE)
Shinoinoport, PA 15077(ADDRESS)
Unit No. 2
ECP 02-0150-03. Order # 200106067Repair/ReplacemneN Organization P.O. No.. Job No. etc.
3. Work Performed By BVPS Maintenance Services(NMAE)
Type Code Symbol Stamp N/A
Shinoincwort, PA 15077(ADDRESS)
4. Identification of System
Authorization No. N/A
Expiration Date N/A
Main Steam (Code Class 2)
5. (a) Applicable Construction Code ASME Section Ill. 1980 Edition. Summer 1981 Addenda,
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s) None
Code Case None
6. Identification of Components
Colrded.'& AWMERemoved. Code
Nameor Name of MNaourcrurer Nai;onal Board Other Year. or stareoComponenf mauracturer Serial No. No. Identification Buib Instatled d
(Ysor
Valve Copes-Vulcan 8320- 2489 2SVS-HCV104 1984 Corrected Yes95453-5-1
Bonnet SPX Valves & 0451- N/A HT # 6928 2004 Installed 2004Controls 97985-*
7. Description of Work Replace Bonnet/Yoke assemblies with replacement Bonnet/Yoke assemblies.
8. Tests Conducted: Hydrostatic* E3 Pneumatic' 5 Nominal Operating Pressure 3 Exempt 5Other E] Pressure _ _ psi Test Temp. Normal Oner. 0F
System Leakage Test in accordance with VT-502.'Record test pressure and temperature
FORM '/z-ADM-0801.F02 REV 2 RTL # A4.414-A
- -LluL
FORM NIS-2 (Back)
9. Remarks Code Data Sheet (N-2) attached. Previous NIS-2 Report Nos.1087.Applicable Manufacturer's Data Reports to be attached
* Serial Number was not recorded.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp Per 1/2 ADM-0801. ASME Xl Repair/Replacement Programm
Certificate of Authorization No. N/A Expiration Date N/A
Signed (, 4L . •r^r A/i.-A. &,y Date 6/'5 2005I Owner or Owner's Vsignee. Title
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by HBS-CT of
/44T-rFo .odI., C.7- have inspected the components described in thisOwneres Report during the period / 0 A( 2 03 to _______ _-_0 _ , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
jo-� J IZZ Z' Commissions ,J! 75'A gr42tnsrtor's Signature National Board. State. Promoce. and Endorsements
Date , 20 05_
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section IIINot to Exceed One Day's Production
Pg. Iof_
1. Manufactured and certified by SPX Valves & Controls 5620 West Road McKean PA 16426(name and addess of NPT Certificate Holder)
2. Manufactured for First Energy Corp., Johnstown, PA 15907(name and address oa purchaser)
3. Location of installation Beaver Valey Nuclear Power Piant Shiopinoort. PA 15077(name and address)
4. Type D-379774 Rev 0 ASMF SA105 e6 600 psi NtA 2004(drawing no.) (mat'l. spec. no.) (tensile strength) (CRN) (year buiW)
5. ASME Code. Section Ul1. Division 1: 1980 Summer 81 2 MA(edition) (addenda date) (class) (Code Case no.)
6. Fabricated In accordance with Consb Spec. (Div. 2 only) NtA Revision NIA Date NIA(no.)
7. Remarks: 8onnet for 10 Class 600 Valhe yer Assembly drawin EF-266209 Rev 8 and F-266210 Rev 10Cust. PO 45125255 SPX Order 97985
Tao 2SVS-PCV1 10B 2SVSPCV10tC 7SVS-HCV104
8: Nom. thickness (in.) NIA Min. design thickness (in.) NIA Dia. ID (ft & In.) Length overall (ft & In.) NIA
S. When applicable. Certificate Holders' Data Reports are attached for each Item of this report:
*1*
AppurtenanceSerial Number
fit 0451.97985.1-4 1040
NationalBoard No.
In Numerical Order
1 NIA
Appurtenance NationalSerial Number Board No.
I. In Numerical Order
(26)(27)~~(28)(29) _ _(30)i11'
'PS(3;(4)(5)
)(6(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)
(I18)('9).(20)(21) .-I
(32) *(33)(34) I __ __ __ __ __ __ __
(35)(36)(37)--(38)(39)(40)(41)(42) _ _ _ _ _ _ _ _ _ _ _ _
(43)(44)(45)(46)(47) . *._._._._.(481(49)(50)
(22)(23)(24)(251(25_,
10. Design Pressure 1115 psi. Temp. 560 f. Hydro. Test Pressure WA;t attemp F
(when applicabWe)* Supplemental hiformation in the form of fists. sketdces. or drawings may be used provided (1) size Is t/2 x 11. (2) information in Items 2 and 3 on thisData Report Is included on eaca sheet. (3) eadc sheet is numbered end the numnber of sheets is recorded at the top of this form.(7198) This form (E00040) may be obtained from the Order Dept_. ASdE. 22 Law Drive. Box 2300. Farfield NJ 07007-2300.
J
FORM N-2 (Back - Pg 2 of)0451497985-
Certificate Holder's 1.4 Serial Nos. through 1-4CERTIFICATION OF DESIGNDesign specifications certified by NA P.E. State Reg. no. _
(when applicable)Design report' certified by NIA P.E. State Reg. no. _
(when applicable)
CERTIFICATE OF COMPLIANCEWe certify that the statements made In this report are correct and that this (these) Bonnetconforms to the rules of construction of the ASME Code, Section IlIl, Divison 1.
NPTCertificate of Authorization No. N-3053 Expires 10/5104Date -/I Name SPX Valves & Controls Signed
(NPT Certificate Holder) (afthrzed rtresenative)
CERTIFICATE OF INSPECTION1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stateor Province of Penna and employed by OneBeacon America InsuranceOf Boston. MA have Inspected these Items described In this Data Report on I-oh-Ar ' and state that tothebest of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASMECode. Section [If, Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning theequipment described In this Data Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for anypersonal Injury or property damage or loss of any kind ariing fr m or connected with this Inspection.
Date /*/2L/V -Sined commissions ['p4 iu 9/. *., I L4 lAthdhoz N dew Lupeaoo PUt 64. d neft-wntz) at4 sUew pmv. ane4 r.
FORM '/2-ADM-080l.F02 REV 2 RTL # A4.414-A
Form No. 1701
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner First Energv(NAME)
78 South Main Street. Akron. OH 44308(ADORESS)
Date 06-06-05
Sheet 1 of 2
Unit No. 2
ECP 02-0150-04. Order# 200016894
2. Plant ' Beaver Valley Power StationINAME)
Shippingport, PA 15077(ADODRESS) Repar/Reptacernent Organization P.O. No, Job No.. etc.
3. Work Performed By BVPS Maintenance Services(NAME)
Type Code Symbol Stamp N/A
ShipDingport, PA 15077(ADDRESS)
4. Identification of System
Authorization No. NIA
Expiration Date N/A
Main Steam (Code Class 2)
5. (a) Applicable Construction Code ASME Section ill, 1980 Edition, Summer 1981 Addenda, Code Case None
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xi Code Case(s) None
6. Identification of Components
Corrected. ASMERemnoved. code
Name of Name of Mansufoaurer Naional Board Otber Year or StampcComponenm Manutacturer Seial No. No. ldrniitcazion Built Installed d
(Yes or_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ N o)
Valve Copes-Vulcan 8320- 2488 2SVS-PCVIOIA 1984 Corrected Yes95453-3-1
Bonnet SPX Valves & 0451- N/A HT # 6928 2004 Installed YesControls 97985-*
7. Description of Work Replace Bonnet/Yoke assemblies with replacement Bonnet/Yoke assemblies.
8. Tests Conducted: Hydrostatic* E] Pneumatic* El Nominal Operating Pressure 3 Exempt ElOther E] Pressure' psi Test Temp. Normal Oper. F
System Leakage Test in accordance with VT-502.*Record test pressure and temperature
FORM W/-ADM.0801.F02 REV 2 RTL # A4.4 14-A
_~L___
FORM NIS-2 (Back)
9. Remarks Code Data Sheet (N-2) attached. Previous NIS-2 Report Nos.1154.* Serial Number was not recorded. Appticatle Manufactures Data Reports to be
attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp Per 1/2 ADM-0801. 'ASME Xl Renair/Replacement Prooram'
Certificate of Authorization No. N/A Expiration Date N/A
Signed G,,O. J Date _ _ _ _ _ 2005Owner or Owner's esignee. Title
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HBS-CT ofAq'-04 dS . 7-. have inspected the components described in this
Owner's Report during the period /a -// - °0 to G7 - - / .- and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code. Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. conceming theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shalt be liable in any manner for any personal injury or property damage or a loss of. any kind arising from or connected with
this inspection.
J 1 Commissions /4 X? ?yltqaeors Sgnature National Board. State. Province, and Endorsements
Date o -z2. /- ,, 20 GoS
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES
As Required by the Provisions of the ASME Code, Section IIINot to Exceed One Day's Production
Pg. IoT__
1. Manufactured and certified by SPX Valves & Controls 5620 West Road McKean PA 16426(name and adiess of NPT Calrticase Holder)
2. Manufactured for First Energy Corp.. Johnstown, PA 15907(name and address of purchaser)
3. Location of Installation Beaver Valley NudearPowerPbant Shipoinport. PA 15077(name and address)
4. Type D-379774 Rev. 0 ASME SA105 eG 600 psi NtA 2004(drawing no.) (mat'l. spec. no.) (tensile strength) (CR11) (year buitt)
5. ASME Code. Section IlIl. Division 1: 1980 Summer 81 2 WA(edition) (addenda date) (class) (Code Case no.)
6. Fabricated In accordance with ConIsL Spec. (Div. 2 only) NtA Revision NWA Date NWA(no.)
7. Remarks: Bonnet for 10 Class 600 ValYe oer Assembly drawina F-266209 Rev 8 andE-266210 Rev. 10Cust PO 45125255 SPXOrder97s985
Taa 2SVS-PCVi0IA 2SVS-PCV101ss 2SVS-PCV101C 2SVS-HCV104
8. Nom. thickness (in.) NJA Min. design thickness (in.) N/A Dia. ID (ft & In.) Length overall (ft & In.) NA
9. When applicable, Certificate Holders Data Reports are attached for each Item of this report:
Appurtenance NationalSerial Number Board No.
In Numerical Order
(1) 0451-97985-1-4 (040 1l N/A
(2)'(3)
(7)
( 81) '_ _ _ _ _ _ __ _ _ _ _ _(10) . -
(12)
(21)
(14)
(17)
(20)__ _ _ _ _ _ _ _ _ _ _
(21) _ _ _ _ _ _ _ _ _ _ _
(22) _ _ _ _ _ _ _ _ _ _ _
(23) _ _ _ _ _ _ _ _ _ _ _ _
(24)(25)_ _ _ _ _ _ _ _ _ _ _ _ _
Appurtenance NationalSerial Number Board No.
In Numerical Order
(26)(27)(281'(29)(30)(31)(32)(33)(34)(35)(36)
(38)(391(40)(41)(42)(43)
(44)(45)(46)(47)(48)(49)(50) _
10. Design Pressure 1115 psL Temp. 560 f. Hydro. Test Pressure N/A attemp F
(when appflcable)Supplemental information hi the form of lists. sketdwes, or drawings may be used provided(1) size Is X11 x I1. (2) information hi Items 2 and 3 on this
Data Report Is included on eadc sheet. (33 eadc sheet Is numbered and the number of theeU I recorded at the top of this form.(719a) hi5s form (E00040) may be obtlained from the Order Dept. ASME. 22 Law Drive, Eox 2300. Fair!ied. NJ 07007-2300.
FORM N-2 (Back - Pg 2 of)0451-97985-
Certificate Holder's 1-4 Serial Nos. through 1 4CERTIFICATION OF DESIGNDesign specifications certified by WA P.E State Reg. no._
(when applicable)Design report certified by N/A P.E. State Reg. no._
(when applicable)
CERTIFICATE OF COMPLIANCEWe certify that the statements made In this report are correct and that this (these) Bonnetconforms to the rules of construction of the ASME Code. Section IIl, Division 1.
NPT Certificate of Authorization No. N-3053 Exptres 10/5/04Date 40=2 D-n / Name SPX Valves & Controls __JSigned I"
(NPT Certificate Holder) (adlhbrized reiresentative)
CERTIFICATE OF INSPECTIONI. the undersigned. holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stateor Province of Penna and employed by OneBeacon Amedca InsuranceOf Boston MA have inspected these Items descnbed In this Data Report on fILL/i( and state that tothebest of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASMECode, Section 111. Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning theequipment described In this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for anypersonal injury or property damage or loss of any kind a' ng f m or connected with this Inspection.
Date ,/2,Vr - Signed 4 C Comnissionsl-.4 fnt . D. IALJ.S vSigned 8N. fd. endoanat band t*(* o PnV. aJd 0s.1
-
FORM %2-ADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1702
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner First Energy(NAME)
78 South Main Street. Akron, OH 44308(ADDRESS)
2. Plant Beaver Valley Power Station -(NAME)
Shippingport, PA 15077(ADDRESS)
3. Work Performed By BVPS Maintenance Services(NAME)
Shinoinpoort. PA 15077(ADDRESS)
Date 06-06-05
Sheet 1 of 2
Unit No. 2
- ECP 02-0150-05. Order # 200136936Repair/Replacerent Orgarization P.O. No.. Job Noa etc.
Type Code Symbol Stamp 1 N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Main Steam (Code Class 2)
5. (a) Applicable Construction Code ASME Section 111, 1980 Edition, Summer 1981 Addenda. _ Code Case None
(b) Applicable Edition of Section Xl Utilized for RepairlReplacement Activity 1989
(c) Applicable Section Xl Code Case(s) None
6. Identification of Components
Corrected. ASMElkctowed code
Name or Name of Namlfacturer Natinal Board Other Year or Sta Mpecomponent N raaurer Serial No. No. Identication Buil Installed N d
(Yes or_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ N o)
Valve Copes-Vulcan 8320- 2491 2SVS-PCV101B 1984 Corrected Yes95453-3-2
Bonnet SPX Valves & 0451- N/A HT # 6928 2004 installed YesControls 97985-*
7. Description of Work Replace Bonnet/Yoke assemblies with replacement Bonnet/Yoke assemblies.
8. Tests Conducted: Hydrostatic* al Pneumatic El Nominal Operating Pressure ED Exempt 0Other E Pressure _ _ psi Test Temp. Normal Oper. *F
System Leakage Test in accordance with VT-502.*Record test pressure and temperature
FORM Ys-ADM-0801.F02 REV 2 RTL # A4.414-A
____ I-I-i
FORM NIS-2 (Back)
9. Remarks Code Data Sheet (N-2) attached. Previous NIS-2 ReDort Nos.1472. Also. replacedApplicable Manufactrer's Data Reports to be attached
Body/bonnet 1-1/2" diameter: Studs-HT # P138. Nuts-J5O5. Added one 1-3/4" diameter Stud-HT #D554 and Nut- HT/ K784. Weld repaired bonnet ID area of damaaed bolt hole. Reolaced Inlet/Outletflange 1-1/4" diameter: Studs-HT # J966. Nuts-HT # FSD.
* Serial Number was not recorded.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp Per 1/2 ADM-0801. 'ASME Xl Repair/Replacement Program"
Certificate of Authorization No. N/A Expiration Date N/A
Signed ALtie. 4w Date 6 h < , 2005 .Owner or Ownrerf' esignee. Tite
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HBS-CT oft >, 0 -. I - LC-7T have inspected the components described in this
Owner's Report during the period /0 -i(--032 to 6 G-2/-0J , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
Ins '5 SgnatureCommissions ,Idy 9'?gddvz- F4 v 5y
National Board. Slate. Province, and Endorserments
Date , 20 -
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section 111Not to Exceed One Day's Production
Pg. I of_
1. Manufactured and certified by SPX Valves & Controls 5620 West Road McKean- PA 16426(name and address of NPTCetificate Holder)
2. Manufactured for First Enertly Corp., Johnstown, PA 15907(name and address of purchaser)
3. Location of Installation Beaver Valley Nuclear Power Pant, Shipinaror1. PA 15077(name and address)
4. Type D-379774 Rev 0 ASMESA105 f6-600 rsi NtA 2004(drawing no.) (matil. spec. no.) (tensile strength) (CRN) (year built)
5. ASMECode. Section lll. Division 1: * 1980 Summer81 2 NtA(edition) (addenda date) (class) (Code Case no.)
6. Fabricated In accordance with Const Spec. (Div. 2 only) NtA Revision NIA Date NIA(no.)
7. Remarks: Bonnet for 0O Ctass 600 Valve rter Assemblv drawing E-266209 Rev 8 and F-266210 Rev. 10Cust. PO 45125255 SPXOrder 97985
Tao 2SVS-PCV10IA 2SVS-PCV1O1B 2SVS PCVIO1C 2SVS-HCV1O4
8:Nom. thickness (in.) NtA Min. design thickness (in.) NA Dia. ID (ft & in.) Length overall (ft & in.) N/A
9. When applicable. Certificate Holders' Data Reports are attached for each Item of this report
Appurtenance NationalSerial Number Board No.
hI Numerical Order
(1) 0451-97985-1-4 (040 1) NtA(2) _ _ _ _ _ _ _ _ _ _ _ _ _ _
(3)(4)(5) _ _ _ _ _ _ _ _ _ _ _ _ _
*(6)_(7)(8) .(9) _ _ _ _ _ _ _ _ _ _ _ _ _
(10)(11)_ _ _ _ _ _ _ _ _ _ _ _ _ _
(12)(13)(14) _ _ _ _ _ _ _ _ _ _ _
(15) _ _ _ _ _ _ _ _ _ _ _ _
(16)(17)(1 8) _ _ _ _ _ _ _ _ _ _ _ _
(1 9) _ _ _ _ _ _ _ _ _ _ _
(20) .(21) _ _ _ _ _ _ _ _ _ _ _ _
(22) _(23)(24)(25) _ _ _ _ _ _ _ _ _ _ _ _ _
Appurtenance NationalSerial Number Board No.
In Numerical Order
(26)(27)~~(28)'(29)(30)(31)(32) _ _ _ _ _ _ _ _ _ _ _
(33).(34)(351(36)
(38)(39)(40)(41)(42)(43)(44)(45)i(46)(47)(48)(49)(50)
10. Design Pressure 1115 psi. Temp. 560 f. Hydro. Test Pressure NWA attemp F
(when applicable)Supplementat iformation i the formof lists. skeiches. ofdrawin~smaybe usedprovided(1 sdzeistitl2 x I1.(2) informationinItems 2and 3on this
Data Report Is included on eaxh shet. 13) each sheet Is numbered and the number of sheets Is recorded at the top of this form.(7198) Tis form (Eo0040) may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fakilieid NJ 07007-2300.
l
FORM N-2 (Back - Pg 2 of )0451-97985-
Certificate Holder's 1-4 Serial Nos. through 1-4CERTIFICATION OF DESIGNDesign specifications certified by N/A P.E State Reg. no.
(when applicable)Design report' certified by NIA P.E. State Reg. no. _
(when applicable)
CERTIFICATE OF COMPLIANCEWe certify that the statements made In this report are correct and that this (these) Bonnetconforms to the rules of construction of the ASME Code. Section Ill. Division 1.
NPT Certificate of Authorization No. N-3053 Expires 1015/04Date = .. - 1.2 L Name SPX Valves & Controls Signed
(NPT Certificate Holder) v (ad~hfirized roresentative)
CERTIFICATE OF INSPECTION1. the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stateor Province of Penna and employed by OneBeacon America InsuranceOf Boston. MA have inspected these Items described In this Data Report on I.WA-/fI .and state that tothebest of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASMECode. Section Ill. Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the inspector nor his employer makes any warranty. expressed or Implied. concerning theequipment described In this Data Report. Furthermore. neither the Inspector nor his employer shall be liable In any manner for anypersonal Injury or property damage or loss of any kind atIng m or connected with this Inspection.
Date 2JLL±Ah .. Sgned 7 C ncmmissions"A Ad iy (/. Afi Ai, vL (hrttt Ndear bup.do4 ltl Ed. wt. B ib) it tate orpth. and no.3
FORM '/-ADM-080 .F02 REV 2 RTL # A4.414-A
Form No. 1703
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner First Eneriv(NAME)
78 South Main Street. Akron, OH 44308(ADDRESS)
Date 06-06-05
Sheet 1 of 2
Unit No. 2
ECP 02-0150-06. Order # 200075699
2. Plant - Beaver Valley Power Station(NAM)
Shippingiport, PA 15077(ADDRESS) Repair/Reptacement Organization P.O. No, Job No.. etc.
3. Work Performed By BVPS Maintenance Services(NAME)
Type Code Symbol Stamp NIA
Shippingport, PA 15077(ADDRESS)
4. Identification of System
Authorization No. N/A
Expiration Date N/A
Main Steam (Code Class 2)
5. (a) Applicable Construction Code ASME Section 1I1, 1980 Edition, Summer 1981 Addenda. Code Case None
(b) Applicable Edition ot Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s) None
6. Identification of Components
Corrected. ARemoved. IL L
Nameat NaM of Mnurtuurcr Natioal Board OtherYr or S.;anpcComponent Manufacturer Serwi No. No. Idntifircaiorl Duilt Ifslted da
Valve Copes-Vulcan 8320- 2490 . 2SVS-PCV10IC 1984 Corrected Yes95453-4-1
Bonnet SPX Valves & 0451- N/A HT # 6928 2004 Installed YesControls 97985-*
7. Description of Work Replace Bonnet/Yoke assemblies with replacement Bonnet/Yoke assemblies.
8. Tests Conducted: Hydrostatic' f Pneumatic' El Nominal Operating Pressure 23 Exempt ElOther 0 Pressure psi Test Temp. Normal Oper. OF
System Leakage Test in accordance with VT-502.*Record test pressure and temperature
FORNIM i-ADM-0801.F02 REV 2 RTL #A4.414-A
LJ&.1
FORM NIS-2 (Back)
9. Remarks Code Data Sheet (N-2) attached. Previous NIS-2 Re ort Nos.1165. Also reolacedApplicable Manufacturer's Data Reports to be atlached
body/bonnet 1-1 /2" diameter Studs. HT # J213 and Nuts, HT # J907.
* Serial Number was not recorded.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp Per 1/2 ADM-0801. "ASME Xl Repair/Reolacement Proqgramm
Certificate of Authorization No. N/A Expiration Date N/A
Signed . Lerr,- Deco. Date / , 2005Owner or ovvoes Designee. Title
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by HBS-CT of
r, 7--. KS O a , C-7 have inspected the components described in thisOwner's Report during the period /0 -(( - 0 ? to 6 -_/_ - 0_r_ ,and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
A_ _ __ -__ 7 Commissions ,t4ff'/- 14 ' A°- ? toInspector's 5Cnature Nationat Board, State. Prognce. and Endorsements
Date 20 ____
FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICALNUCLEAR PARTS AND APPURTENANCES*
As Required by the Provisions of the ASME Code, Section IIINot to Exceed One Day's Production
Pg. 1o0__
1. Manufactured and certified by SPX Valves & Controls 5620 West Road McKean PA 16426(name and address of NPT Certiricate Holder)
2. Manufactured for First Energy Corp., Johnstown, PA 15907(name and address of purchaser)
3. Location of Installation 8eaver Valley Nuclear Power Pant Shippinoport, PA 15077(name and address)
4. Type D-379774 Rev 0 ASME SA10S 86 600 psi NtA 2004(drawing no.) (mat'I. spec. no.) (tensile strength) (CRM (year built)
5. ASME Code. Section 11, Division 1: 1980 Summer 81 2 NIA(edition) (addenda date) (class) (Code Case no.)
6. Fabricated In accordance with Const. Spec. (Div. 2 only) NtA Revision N/A Date NtA(no.)
7. Remarks: _ onnet for 10 Class 600 Valve nerAssembly drawina E-266209 Rev 8 and F-266210 Rev 10CusL PO 45125255 SPX Order 97985
Taa 2SVS-PCVIOIA 2SVS-PCV1018- 2SVS PCV1OIC 2SVS-HCV104
8. Nom. thickness (in.) N/A Min. design thickness (in.) N/A Dia. ID (ft & In.) Length overall (ft & In.) N/A
9. When applicable. Certificate Holders' Data Reports are attached for each Item of this report:
Appurtenance NationalSerial Number Board No.
Ih Numerical Order
(1) 0451-97985-1-4 (040 11 NIA(2)(3)
(4) * _ _ _ _ _ _ _ _ _ _ _ _ _
(14).
(5)(6)
(8)(9)
(1 0) _ _ _ _ _ _ _ _ _ _ _
(12) _ _ _ _ _ _ _ _ _ _
(13)(14)__ _ _ _ _ _ _ _ _ _ _
(15)(16)(17(1 8) _ _ _ _ _ _ _ _ _ _ _ _
(1 9).(20)(21)(22) _ _ _ _ _ _ _ _ _ _ _
(23) _ _ _ _ _ _ _ _ _ _ _
(24) _ _ _ _ _ _ _ _ _ _ _ _
(25)_ _ _ _ _ _ _ _ _ _ _
Appurtenance NationalSerial Number Board No.
In Numerical Order
(26)(27) _ _ _ _ _ _ _
(28)(29)(30)(31)(32)(33)(34) . -(35)(36)(37)(386(39)(40)(41)(42) _ _ _ _ _ _ _ _ _ _ _
(43)(44)(45)(46) _ _ _ _ _ _ _ _ _ _ _ _
(47)(48)(49)(50)
10. Design Pressure 1115 psi. Temp. 560 i. Hfydro. Test Pressure W/A attemp F
(when applicable)* Supplemental Information in the form of lists. sketche, or drawings may be used provided 1) size Is 8112 x 11. (2) information in Items 2 and 3 on thsData Report Is Included on each eheet (3) each sheet I numbered and the number of sheets Is recorded at the lop or this form.(7198s This form (E00040) may be obtained from the Order Dept.. ASdE. 22 Law Drive. Box 2300. Faifiel. tJ 07007-2300.
FORM N-2 (Back- Pg2of)0451-97985-
Certificate Holder's 14 Serial Nos. through 14
CERTIFICATION OF DESIGNDesign specifications certified by NA PrE. State Reg. no._
(when applicable)Design report certified by NWA P.E. State Reg. no._
(when applicable)
CERTIFICATE OF COMPLIANCEWe certify that the statements made In this report are correct and that this (these) Bonne(conforms to the rules of construction of the ASME Code. Section III, Division 1.
NPT Certificate of Authorization No. N-3053 Expires 1015(04Date Name SPX Valves & Controls S ign
(NPT Certificate Holder) (adbibrized rEtresentative)
CERTIFICATE OF INSPECTION1. the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the Stateor Province of Penna and employed by OneBeacon America InsuranceOf Boston, MA have Inspected these Items described In this Data Report on 1p orA-AJ1Y and state that tothebest of my knowledge and belief. the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASMECode, Section Ill, Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning theequipment described in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for anypersonal Injury or property damage or loss of any kind a * Ing f rm or connected with this Inspection.
Date 2L*L.. Signed ed ± Comnussionse-'d ft i'/. A'/L (Aswfted Nudewr D pectM [al ad. ond. emmsernents) and state or pm(. and no.1
FORM Vz-ADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1704
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.$NAMEl
76 South Main Street - Akron, OH 44308
Date 06117/2005
Sheet 1 of 1(ADDRESS)
Beaver Vallev Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippingport, PA 15077(ADDRESS)
3. Work Performed By BV-Maintenance(NAME)
Rt. 168 - Shippincport, PA 15077(ADDRESS)
Order #200094959Repair/Replacement Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. NIA
Expiration Date N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section IlIl 1971 Edition. W'72 Addenda, - Code Case
(b) Applicable Edition of Section Xl Utilized for RepairlReplacement Activity_ 1989
(c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components
Corered. ASMERlrnoed. Code
Name of Name or Nlanufwctrer National Board Oiher Yer or StamnpedComponent Mianufacturer Serial No. No. ldentification Built Irntl11ed (Yes or No)
Pipe Schneider Power N/A N/A 2-SWS-030-143-3 1986 Corrected Yes
7. Description of Work Replaced pipe nipple and flange.
8. Tests Conducted: Hydrostatic* D Pneumatic' E Nominal Operating Pressure Z Exempt [3
Other D3 Pressure psi Test Temp. OF
*Record lest pressure and temperature
_- - I . l ta
FOR.NI `/2-ADNI-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks No Code Data Reports available. Replaced: 6' Sch. 40 Pipe nipple - Ht. #X63924.Applicable Manufacturers Data Reports to be attached
6" Flance - Ht. #S1254- 3/4" diameter studs - Ht. #P127. 3/4" diameter nuts - Ht. #F864.
-
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A
Signed a g e s SC.I' ID S,
Expiration Date
,!IIZr Date
NIA
June 17 20 05E_ Uaner or Owner's Designee. Title '
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB Cr of
Hartford. CT have inspected the components described in this
Owner's Report during the period / ° - //- 0 3 to 6 - A 0 - 6J' . and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
Z3&,� _J )e��/ Commissions /.4 ' 3FMY -I-,-'-I nature National Board. State. Province. and Endorsernents
Date i, o - 220 05S
-
FORM '/2-ADNI-0801.F02 REV 2 RTL # A4.414-A
Form No. 1705
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date
Sheet
06/15/2005
I of 2
2. Plant
(ADDRESS)
Beaver Valley Power Station(NAME)
Route 168 - Shiooinaport, PA 15077
Unit No. 2
Order #200029304(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Rt. 168 - Shioninciort, PA 15077
Repair/Replacem'.ent Organizaton P.O. No.. Job No. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Chemical and Volume Control (Class 2)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda. - Code Case
(b) Applicable Edition of Section Xl Utlized for Repair/Replacement Activity 1989
(c) Applicable Section Xi Code Case(s): None
6. Identification of Components
I
Corrected, ASIMERenrioved. Code
Name of Narme or Manufacturer National Board Other Year or StampedComponent Manufacurer Serial No. No. Identification Built Installed (Yes or No)
Check Valve Kerotest LA2-10 9439 2CHS-42 1976 Corrected Yes
7. Description of Work Seal welded body to c6ver.
8. Tests Conducted: Hydrostatic* Dj Pneumatic* E Nominal Operating Pressure ED ExemptE
Other E Pressure psi Test Temp. OF
*Record test pressure and temperature
-IlL
FORM /2-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Copy of Code Data Report attached.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A
Signed 4 1 L ) - -
Expiration Date
. Date
N/A
July 1 20 05% Owner or Owner's Desgnee. Titte I
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period ( e .- -0 a' to V- -7 _ a *and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
Insp sgnatureCommissions ,/Jaf Adz- g AJrCa A9,s3FY
National Board. State. Province. and Endorserments
Date , 20 05__
Arm 1 1?4q1"'A 6y ike. IPv'1K 1t5yg o 1 ith,:AS7 0 r, )ItIur
3525 Libert' Ne.e
(4w & ADfroab .4 N.A40 10#11)BP. O. Iox 355
2. Is..*..* l btinghouse Electric Corp. *Pittuburh, PA - ,,, . 546-CCF-17825213V. .
tHewe ed ^e.&og
J.' Owe* 2)uaue~znv Libt C2Fpntr _J ml '4. ̂ Be aver Vallo1No. 2
5. Z&vvt,., ;" Check Valve * H LA2-i LA2-8, LA2-10, LAP-6, A2-18, LA2_19,
LA2-21, LA2-23, LA2-25. . .. i
(M.VIf 0eI49joibeft .etwW* lte b"e to "O d eio"*. .
_ v_ .
-servicesradioact.WVo flui t di .Co) a.Y D-9911-(2) Rev.D P ., H. Dratfinsky
Sb. I1)
4 Zeelp Cmr4;1;&S r25 p6 i 2 * at 1rmi= -ti -clew
* rvst"s*eI ITv mww) ..
7. Titv na.iuLmd. dst", Irvsamon. &ad voomesomop campIies with A5WZ Ca. Sectlon 'II. Cim2s1 .
n971 Winter 1972* Ad_, _ e* _D____C__No.
-I. Ie13ttu**-not P*". It . Wampta"swwr .1 1 08
... . . _ __ .S8. f t. * '. *_____"___,_____._._,
!g -- � " -, .2, , Pj;psF-, �4 P / -...,. ji IXl�;" I ,'! -, I -�.,
A _ .
I I t 1. r, - *_, **........ t . 7, _ . .....'..
., '' f,_,' ._~~5 __;.. _ __
40 -
__ - _ _ I F_I_ __ ,_
_ .,-~__ _ V
I.
- - -a - -
__.__ 1W _. _ ._ ..
lb$ 1W,04AX%
bcodyc _ver
~~-??1-._._ __S
. . SAb2i 01
C~P..... - ot
-. - . ...
-. i *1... 1
a . . .- I.
. 1.
*1* . _ *...* .*. .. _ .... ..........._......
I I I ' - III IDto I 21 , ,;1.0 I J Io 1 ,,JItI. I on I"
.%.ilt .I's PAl .. ..- .a :to.'. -*h S, .. I .S. * -'Pe. . ' *I I . *#*"'PI t,1 *10 III g . *to * 1 * J" l. u . a~hloo * t , , na l **1,o * h .. . 1.P. I '.* ,, ., AI- ._ ,,,. ,Ae.O . .-.. p * ,.,I 614o, go %.A0,WS~DJ *AJ oo . oS .es so0-0 *e4 ootmoJ of ". # MtIb Isvro
3 1$ Ti.. eft. ItC , P *. 3o g1ea.rA* 1 the.0Pt Ou Doti., ASA t , INl t. J:' $., Mr. " e, H.' *
MUMN UPwY-1 (s.k)
I 4ortat- $guy ;40 W.o ,.Co er N*m. e
(c) II ... -t _ i-I'Cef Im
+ -_I
_ . I
*I.___I _1 - - ._ -No. - -,*t~ "A-" Pt"
Carpen_ ht t sylœ un -* . , . -? . - _ _
. . . ; *;
_ . -
_ , =
. . ,
- _ _ . - . . _ _ . . _
_ . _ _ _
Z. Ie.W!-at11A;c tet. 5400 pSi
-4..--c- w *W tk a nhlEw|alr^xk qU -7 -V - M- --- .- ___ -
_, _ . w ._ _& V_ _.w
D;aI1a iaI~rrm±*.4 tl fll e Irbrrlt
-S-3 r1,;re" a MrX as - . 1D
v>r;& lip;Ificmi'" ctrti.e bv . KStrts OA23711s np..1 cvfi"w l i..U
LI) sisiatme, a.mt rq*;rJ. Liss *me .
t 1Mrmufne-rur-Imo r_-i- '11 , S
nneth Dlube'A
,I ) Prof1. ESg. S4aste A, s l) ptel AI a jl Reg.X N66 .
SC crlrtt ^thi St%* UA4tcqt) Che is Als Ir uvt hcotrf.
.. ^April 9 _l9 76 Si d KoerOtet -s9. 10/-A3/7 -
CSISMICM41t 01 A1.,10;*MOa NO. , > ......... 8 _#2pitf _- 10Z2gZ7
'4-~iS.- .vCAro1e °
CUMMCAT. tOF qIOP lVN~IECTO 't.
1. d.r .. '.'.'.;o*. b4;.g ** w isgas;ei lowed Iy thf National Kosr.' Iei Klre aod Pte*iwee Vespal In. r.fs
'41114 *th 5#4.tr a Pso...mce *t _!=Z5i L . ua ert*; r.J :; he.ne ec^I(- .t.ror. . .i.t.- v, if oarve F he .qSi o"& IJ.scfIbbe in ihos nat a
-RcO -a ... ,_ -J 41joc shat to* ihe bijl *I M% Ln.1,4eJ1r ij J A11e le, she t 4SAnUIIiutihas trns feuird sIst ,vuwnte in aetewdaqer *hgh the *rTl'ersb4 c iofla 1 AM41 I ,Jr,. .sr flt"
IBy -so ih,&t rhislca rit, %ol 1 ts h Insr-t viri h fif hi% -0-to f^A1.e..l i. % AIIAMI%. * rfrieir 'l 611 ion.lovJ* celft'romA,' Ihe C w, n Jr., Iit'eJ *; i . )seAI mIr et-."i I uvlhi rr. StrIth, her ' ..j.r.. ..e ...to-it hi% rpmn l.arlf .011 h e liable ift ..I
ImAnoto 1. 4jn' rv#i s iA lr . r6$ilrif .MM 4' u1 * I, WA a ^J an5 A , %inJ ISIC I ts-," off .4111C ie %.ih she. tA , V -141%. I
I1... A r:1 9IIiII- ; 7I s*m9..fb
. 4*tg...*g It ... i.Ii- D ;.... ./ //
. Nef O.... SII .... , O. I SO P 0. ,^ P t . ...AOof
I
FORM V/i-ADM-0801.F02 REV 2 RTL im A4.4 14-A
Form No. 1706
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron. OH 44308
Date
Sheet
06/17/2005
-1 of 1(ADDRESS)
Beaver Vallev Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippinpport, PA 15077(ADDRESS)
3. Work Performed By BV-Construction Services(NAME)
Rt. 168 - ShioDinaDort. PA 15077
Order #200061984RepairlReplacerrment Orgarization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, N/A Code Case
(b) Applicable Editon of Section XI Ulized for Repair/Replacement Acivity 1_989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Corrected. ASMERemoved, COde
Name or Name of Manufacturer National Board Other Year or StampedComponent Manufacturer Serial No. No. ldentificarion Built Installed (Yes or No)
Check Valve MissionrrRW Inc B4583 N/A 2SWS-107 1976 Removed Yes
Check Valve Crane Nuclear D0939 N/A 2SWS-107 2002 Installed Yes
7. Description of Work Replaced valve with spare and inlet/outlet flange studs and nuts.
8. Tests Conducted: Hydrostatic* E Pneumatic* E Nominal Operating Pressure E Exempt EOther E Pressure psi Test Temp. OF
'Record lest pressure and lemperature
1L E
FORNI Yi-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Replaced valve with rebuilt spare from 2SWS-57 location. Replaced 1-1/4" inlet/outletApplicable Manufacturers Data Reports to be attacred
flange: studs- Ht. #P408 and nuts- Ht. #A201.---
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A Expiration Date
Signed &wor.. Spc DateOwner or Owner's Designee. Title
N/A
20 05_- f _ -
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period /0 - //- 03 to L(/-. 7- OF, and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
7"ors sSignatureCommissions qua z-r /*f.?Z~'
National Board, State. Province. and Endorsemrents
Date , 20 0 S'-Date . 0 0'S,
FORM Vi-ADM-0801.F02 REV 2 RTL X A4.4 14-A
Form No. 1729
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C. Date 06/15/2005(NAME)
76 South Main Street - Akron, OH 44308(ADDRESS)
Sheet 1 of 2
2. Plant Beaver Valley Power Station(NAME)
Route 168 - Shioninonort, PA 15077
Unit No. 2
(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Rt. 168 - ShippinQport, PA 15077(ADDRESS)
Order #200020473RepairfReplacernent Organization P.O. No.. Job No., etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Residual Heat Removal (Class 2)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda, 1501 & 1649 Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Secion Xl Code Case(s): None
6. Identification of Components
Corrected, ASMERernoved. Code
Narne of Nrne of Manufacturer National Board Other Year or StarnpedCornponcnt Manufacturer Serial No. No. Identification Bult Installed (Yes or No)
Relief Valve Crosby Valve N56904-00-0061 894 2RHS-RV721 A 1981 Removed Yes
Relief Valve Anderson N56904-00-0075 N/A 2RHS-RV721 A 2003 Installed YesGreenwood Crosby
7. Description of Work Replaced valve, and one flange nut.
8. Tests Conducted: Hydrostatic* rl Pneumatic* fl Nominal Operating Pressure Z Exempt ElOther LI Pressure psi Test Temp. PF
'Record lest pressure and termperature
FORM '/--ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Replaced valve for testing purposes. Replaced one 3/4" dia.
Nut: Ht. #M677.Applicable Manufacturers Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp. N/A
Certificate of Authorization No. N/A
Signed 2 0D
Expiration Date N/A
;1 !Sp. 1 l-t Date Sc1 7 , 20 05I- Owner or Owner's Designee. Title /
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period Io -// - 03 to q 7-OS---, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
4ao-al / Commissions I, J. 1'/-'.2? e ?,. ~4ctor's Signature National Board, State. Province, and Endorsements
Date ;72 0C,- 20 0r
Q.C.-44C-1Sheet 1 of 2
FORM NV-1 FOR SAFETY AND SAFETY RELIEF VALVESAs required by the Provisions of the ASME Code Rules
DATA REPORT
1. Manufactured By Anderson Greenwood Crosby, 43 Kendrick St., Wrentham, MA 02093Name and Address
Model No. JB-35-TD-WR Order No. U415250000 Contract Date 4/11/02 National Board No.
2. Manufactured For FIRST ENERGY CORP. Order No._ ___ _Name and Address
3. Owner FIRST ENERGY CORP.Name and Address
4. Location of Plant BEAVER VALLEY POWER STATION
5. Valve Identification SPARE Serial No. N56904-00-0075 Drawing No. DS-C-56904 REV. D
Type SAFETY RELIEF Orifice Size 2.030 Pipe Size - Inlet 3 Outlet 4Safety, Safety Relief, Pilot, Power Actuated Inch Inch Inch
6. Set Pressure (PSIG). 450 400 FRated Temperature
Stamped Capacity 900 GPM WTR @70 DEG.F @ 10 % Overpressure Blowdovm (psig) 10% OF SP
Hydrostatic Test (PSIG) Inlet 725 Complete Valve 425
7. The material, design, construction and workmanship comply with ASME Code, Section HI.
Class 2 Edition 1971 Addenda Date WINTER 1972 Case No. 1501 & 1649
Pressure Containing or Pressure Retaining Components
Serial No. Material Specification
a. Castings . Identification Including Type or Grade
Body N90445-67-0095 ASME SA351 GR.CF8M
Bonnet N90447-59-0079 ASME SA216 GR.WCB
b. Bar Stock and Forgings
-Support Rods _
Nozzle N90149-96-0192 ASME SA479 TYPE 316
Disc Insert N90446-79-0180 ASME SA479 TYPE 316
N88697-47-0285
Spring Washers N88697-48-0290
Adjusting Bolt N88698-73-0236
Spindle - N88700-26-0186'
ASME SA193 GR.B6
ASME SA193 GR.B6 .
ASME SA193 .GR.B6
I IL
Q.C.-44C-1Certificate Holder's Serial No. N56904-00-0075 Sheet 2 of 2Form NY-i (Back)
Serial No.Identification
NX2618-0085
Material SpecificationIncluding Type or Grade
ASTM A276 TYPE 316c. Spring
d. Bolting
e. Other Parts such as Pilot Components_
Bonnet Stud N96125 ASTM A453 GR.660
Bonnet Stud Nut N95997 ASME SA193 GR.S6
Disc Holder N95397-50-0045 ASME SA479 TYPE 316L
We certify that the statements made in this report are correct.Anderson Greenwood Crosby
Date *020 03 Signed Wrentham.NMA By TD,. /77R&rManufacturer
Certificate of Authorization No. N-1878 Expires Sep. 30, 2004Date
. I.CERTIFICATE F UPSHOP INSjPEUT0U
I, the undersigned, holdi ivalid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and theState or Province of - -and employed by
ABS Group Inc., Houston, Texashave inspected the equipment described in this Data Report on
'PR r /- /4 20 d 3 and state that to the best of myknowledge and belief, the Manufacturer has constructed this equipment in accordance with the applicableSubsections of ASME Section III.
By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied,concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from orconnected with this inspection.
Date Xp P lY/ /•< 20o 1., ,, .X, , ,-. -
1/.2 /t , -,JZ Cmmissions(Ins e yfor) I
i$8z ?i75?(Nation'al Board, State, Province and No.Y
FORM Y/2-ADM-0801.F02 REV 2 RTL # A4.414-A
Form No. 1732
* FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner FENOC(NAME)
76 South Main Street - Akron. OH 44308
Date 7/5/05
Sheet 1 of 1
jADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Shippingport. PA 15077(ADDRESS)
3. Work Performed By BVPS - Nuclear Construction(NAME)
Shinpinaport. PA 150077(ADDRESS)
200028819Repair/Replacement Organization P.O. No, Job No., etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A. .. . . ... . . . . . . . . .. . . . __ ..
-- 4-'Ten6fification'ofSysttem -. CohT-inment DePressurization . - -
5. (a) ApplicableConstructonCode Section III 1271Edition, 2 Addenda, NIA Code Case
(h) Applicable Editon of Section Xl Ublized for Repair/Replacement Ac.tivit18E
(i) Applicable Section Xl Code Case(s)
6. Identification of Components
Corrected. ASNERemoved, Code
Name of Name of Manufacturer National Board Other Yerw or StampedComponent Manufacturer Serial No. No. Identification Built Installed (Yes or No)
Snubber Pacific Scientific 18658 N/A 2QSS-PSSP154X _ Replaced No
Snubber Pacific Scientific 6266 NIA 2QSS-PSSP154X _ Replacement No
7. Description of Work Replaced snubber with soare for testing/refurbishment nurmoses.
8. Tests Conducted: Hydrostatic* E Pneumatic' D Nominal Operating Pressure El Exempt a
Other El Pressure psi Test Temp. OF
'Record lest pressure and temtperature
t
FORM /2-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks The snubber was reDlacedwith a used snare. No Code Data Reports are available.Applicable Manufacturer's Data Reports to be attached
Snubber are considered non-NF comronents (non-code).
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp. N/A
Certificate of Authorization No. NIA Expiration
---
Signed _ _ _ _ __ _Owner or Owner's Designee, Tite
Date N/A
Date i-U4 ~
, , . . . . _ ........ .. . . ..
20 o5
CERTIFICATE OF INSERVICE INSPECTION
1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /0 -i'- 3 a to Y -' 7- Of . and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
uors SgnatureCommissions G, ,/, ih'V I L;t' g f
National Board. State. Proince, and Endorsements
Date 7-_ _-_- 20 0 r
FORM i/z-ADM-080I.F02 REV 2 RTL # A4.4 14-A
Form No. 1733
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron. OH 44308
Date 04/29/2005
Sheet 1 of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippincport, PA 15077(ADDRESS)
3. Work Performed By BVPS Construction Services(NAME)
ShipDinaoort, PA 15077
Work Order #200029381Repawr/Replacernent Orgaruzation P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section Ill 1971 Edition, W'72Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Ublized for Repair/Replacement Acivity 1989
(c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components
consected, ASMERernoved, Code
Narne of Naene of Manufacturer National Board Other Year or StampedCo rr onent 1a nufacturer Serial No. No. Identification Built Innulted c (Yes or No)
Valve Walworth D-66536 1794 2SWS-MOV105A 1979 Removed Yes
Valve SPX Valves & 0320-87110-1-3 . N/A 2SWS-MOV1OSA 2003 Installed YesControls
7. Description of Work RePlaced valve with new valve type.
8. Tests Conducted: Hydrostatic* El Pneumatic* E] Nominal Operating Pressure ED Exempt ElOther El Pressure psi Test Temp. °F
'Record test Dressure and termperature
FORNI /2-ADMN-0801.F02 REV 2 RTL ftA4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Replaced valve and section of 16" pipe (P.O. #45126828) Ht #A64217) andApplicable Manufacturer's Data Reports to be attached
added two flanges (P.O. #47055503. Ht. #227C122) and bolts (P.O. #45151610, Ht. #G8327). Previous NIS-2 Data
Report No. 118. The System Leakage Test was performed but not witnessed. The welds were visually inspected
with no evidence of leakage and were then NDE surface examined with no indications present per CR 05-03277.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorztion o. N/A
Sionnri S r,4A 1,
Expiration Date
&- Date
N/A
June 28 20 05Owner or Owner's Designee. lutb
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period a a -/1- 0 3 to 9d-A. 7- O fr, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
x'p~
Commissions - 1 gtnspectorpdnature National Board. State, Province. and Endorsements
Date , 20 -2sZ
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section III, Division 1
Pg. 1 of
1 Manufacturedandcertifiedby SPX Valves & Controls, 5620 West Road, MeKean, PA 164261. Mnufctued nd ertfie by(name and address of N certificate Holder)
2. Manufactured for First Energy Corp., PO Box 3611, Akron. OH(name and address of Purchaserl
3. Locationof Installation First Energy Corp., Shingingport Hill Road, Shinpingport. PA(name and addressl
4. Model No., Series No., or Type Butterfly Drawing f_-376fl 5 Rev. a CRN - N/A
5. ASME Code, Section III, Division l: 1971 thru W72 3 N/Aledition) (addenda datel (dassi Code Case no.)
6. Pump or valve Valve Nominal Inlet size 1fn Outlet size fin
7. Material: SA351 Cover SA479 SA351 SA193(a) valve Body rFRM ACrm e ..31 C Disk r..M Bolting A t(b) pump Casing Cover Bolting
la)Cert.
Holder'sSerial No.
0320-87110-1-3
lb)Nat'l
BoardNo.
N/A
IC)Bodyr-asing
SerialNo.
CN 607931
(d)BonnettCover
SerialNo.
030 3
Ce)Disk
SerialNo.
CN 625a31
* Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size Is 8'/1 x 11, (2) Information in items I through 4 on this Data Reportis included on each sheet, (31 each sheet Is numbered and the number of sheets Is recorded at the top of this form.
(7/981 This form (E00037) may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300, Fairfield. NJ 07007-2300.
L&
FORM NPV-1 (Back - Pg. 2 of J
Certificate Holder's Serial No. n3-20- 8 711 0-1 -3
S. Design conditions 1 50 psi 1 60 IF or valve pressure class N/A(pressurel (temperaflxel
9. Cold working pressure 275 psi at 100'F
10. Hydrostatic test 425 psi. Disk differential test pressure 1 5n psi
11. Remarks: Customer P0 71227B5
CERTIFICATION OF DESIGN
Design Specification certified by Francis Gardner P.E. State PA Reg.no. 36614-EDesign Report certified by N/A P.E. State Reg. no.
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of theASME Code, Section III, Division 1.N Certificate of Authorization No. N-3052 Expires 11/s/n4
Date Io-Z7<%23 Name SPX Valves & Control15 Signed 9 i 1IN Certlficate Hotder) I (A.Mhorired re resentative}
CERTIFICATE OF INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provinceof Penna andemployedby OneBeacan American Insurance Companv
of Boston, M A have inspected the pump, or valve, described in this Data Report on/0 Z2-Z- 3 , and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve,
In accordance with the ASME Code, Section liI, Division 1.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component describedIn this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damageor a loss of any kind arising from or connected with this inspection.
Date '°d2=-2L'r3 &iComm issions_ Priced-Nuclear -nspector)- --(----- en Ints) andostate or-prov;andsnow---- -
ll For manually operated valves only.
FORM Vi-ADM-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1734
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date 04129/2005
Sheet 1 of 2
2. Plant
(ADDRESS)
Beaver Valley Power Station(NA?.E)
Rnotet 168 - Shinninnonrt PA 15077
Unit No. 2
(ADDRESS)
3. Work Performed By BVPS Construction Services(NAME)
Shiopincport, PA 15077(ADDRESS)
Work Order #200029404Repair/Replacernent Organization P.O. No, Job No. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, W7 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 5
(c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components
Corrected. ASMERemoved. Code
Name of Name of Manufacturer National Board Other Year or StampedComponent Manufeaturer Seriat No. No. Identification Bulb Installed (Yes or No)
Valve Walworth D-66538 1796 2SWS-MOVI05C 1979 Removed Yes
Valve SPX Valves & 0320-87110-1-4 N/A 2SWS-MOV105C 2003 Installed YesControls
7. Description of Work Replaced valve with new valve type.
8. Tests Conducted: Hydrostatic* [] Pneumatic* El Nominal Operating Pressure 1 Exempt ElOther M Pressure psi Test Temp. ° OF
*Record test pressure and temperature
FORNM '/-ADM-080I.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Replaced valve and section of 16" pipe (P.O. #45126828) Ht #A64217) andApplicable Manufacturers Data Reports to be attached
added two flanges (P.O. #47055503. Ht. #227C122) and bolts (P.O. #45151610. Ht. #G8327). Previous NIS-2 Data
Report No. 1130. The System Leakage Test was performed but not witnessed. The welds were visually inspected
with now evidence of leakaae and were NDE surface examined with no indications oresent Der CR 05-03277.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No.
SigneeV*UC;)
N/A Expiration Date N/A
-'&AJJ;.r- !rl74f Date June 28I,__. .,>.
20 05Owner or Owner's Designee, Tle I
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period / 0-// - 0 3 to 1- 0 t 2 -CE and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
_ _ __ __ __ __ "7 Commissions A -, a *Inspectors ;ig e National Board. State. Provnce, and Endorsements
Date 7 , 20 ____
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the'ASME Code, Section 11I,.Division 1
Pg. 1 of _
1. Manufacturedandcertifiedby SPX Valves & Controls, 5620 West Road, McKean, PA(name and address of N Cenificate Holder)
2.Manufacturedfor First Energy Corp., PG Box 3611, Akron, OH(name and address of Purchaserd
3. Locationofinstallation First Enerav Corn., thippinoctort Hill Road. Shippingport, PA(name and address)
4. Model No., SeriesNo.,orType R f f I fly Drawing il-37fh Bn3 Rev. 4 CRN N/A
5. ASME Code, Section [it, Division 1: 1971 thru W72 3 N/AIedltion) laddenda date) Icass) IC(ode Case no.)
6. Pump or valve Valve Nominal inlet size 16 Outlet size 16(in.) (in.l
7. Material: SA351 Cover SA479 SA351 SA193(a) valve Body rCFlM ,'net' 21h Disk. - Eom Bolting F8M(b) pump Casing Cover Bolting
(a)Cert.
Holder'sSerial No.
lb)Nat'l
BoardNo.
(1 tt w N / A
- (c)BodytCasing
SerialNo.
CN 607932n..'
(dl le)BonnettCover Disk
Serial SerialNo. No.
0304 - CN 6n7946
. .
Supplemental information in the form of lists, sketches. or drawings may be used provided (11 size is 8t/1 x 11, (21 Informalion In Items 1 through 4 on this Data ReportIs Included on each sheet, (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.
(71981 This form (EO00371 may be obtained from the Order Dept. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 07007.2300.
II I in
FORM NPV-1 (Back - Pg. 2 of )
Certificate Holderes Serial No. 0320-871 10-1-4
8. Design conditions 1 50 psi 1~n 'For valve pressure class(pressure) (tempernture)
9. Cold working pressure 2 7 5 psi at 100*F
N/A (1)
10. Hydrostatic test 422 5 psi. Disk differential test pressure 150 psi
11. Remarks: Customer PO 7122785
CERTIFICATION OF DESIGN
Design Specification certified by Francis Gardner e r P.E. State PA Reg.no. 36614-EDesign Report certified by N/A P.E. State Reg. no.
CERTIFICATE OF COMP LANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of theASME Code, Section 1I1, Division 1.N Certificate of Authorization No. N-3n52 Expires in/5 M/ A
Date /Of-27gName qPY vn1 Vp-m x rrnnrnl Q SignedIN certificate Holder) / iautsorized repreentativel
CERTIFICATE OF INSPECTION
1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provinceof Penna and employed by OneBeacon America Insurance Company
__ of Bos ton. M A have inspected the pump, or valve, described in this Data Report on
/0- - 2-0123 , and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve,in accordance with the ASME Code, Section 1II, Division 1.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component describedin this Data Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damageor a loss of any kind arising from or connected with this inspection.
Mate-° 10 Z2<>03 R4-2(,^co mison-. An_ , _z4 .- Lommlslons ._..Q rized Nudear Inspecorl INat'L Sd. linr. endmeni) and stat. or prov. and no.1
11 For manually operated valves only.
FORM Y/2-ADM-080 .F02 REV 2 RTL # A4.414-A
Form No. 1755
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308- -l-nr c
Date 06-21-2005
Sheet 1 of 2
2. Plant
%-- I.Jf..I
Beaver Valley Power Station(NAME)
Route 168 - Shinninonort- PA 15077
Unit No. 2
Order #200087074- ---- -
3. Work Performed
Ship
(ADDRESS) RepairlReplacement Organizatoen P.O. No.. Job No.. etc.
By BV-Maintenance Type Code Symbol Stamp N/A(NAME)
pincport, PA 15077 --- Authorization No. N/A(ADDRESS).
Expiration Date N/A
4. Identification of System Chemical and Volume Control (Class 2)
5. (a) Applicable Construction Code Section III 1971 Edition, W73 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/ReplacementActivity 1989
(c) Applicable Section Xl Code Case(s): N-416-2
6. Identification of Components
corrected. ASMEltreoved. Code
Name of Narne or Manufacturer National Board Other Year or StampedCononent Manufacturer Serhi No. No. Identirication Built Installed (Yes or No)
Globe Valve Kerotest EO1 1-3 6067 2CHS-484 1975 Removed Yes
Globe Valve Velan 051003-3 N/A 2CHS-484 2005 Installed Yes
7. Description of Work Replaced valve with spare. - -
8. Tests Conducted: Hydrostatic* El Pneumatic* E Nominal Operating Pressure ED Exempt ElOther El Pressure psi Test Temp. OF
'Record test pressure and temperature
FORM 'ArADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks NPV-1 Data Report attached. Previous NIS-2 Report No. 1354. Also removed andApplicable Manufacturer's Data Reports to be attacied
reinstalled pipe support #2CHS-PSR01 1 R as part of 2CHS-484 replacement. New valve was
manufactured to ASME Section III 1980E-W'81A.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A Expiration Date N/A
Signed •c&r )1t ,C2 e Date June28 ,20 05Owneror Owner's Designee. TitleI
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
'and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period /O - a 3 to V-'2 7- 0 °, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
J- Z;"," �- Commissions Zig 2,signature National Board, Stare. Prmnce, and Endorsements
Date 20 0 -'D t 2
DATA PACKAGE NO. 051003
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES *
As Required by the Provisions of the ASME Code, Section III, Division 1
Pg. 1 of 2
1. Manufactured and certified by VELAN INC. 2125 WAjMAVE,MONTREAL.QUEBEC CANADA H4M1T6(name and address of N Certificate Holder)
2. Manufactured for -FIRST ENERGY NUCLEAR PURCHASING SBX-P PO BOX 345 SHIPPINGPORT, PA(name and address of purchaser)
3. Location of installation FIRST ENERGY BEAVER VALLEY POWER ST. ROUTE 168 SHIPPINGPORT,PA(name and address)
4. Model No., Series No., or Type: Globe Drawing P011-382230-NO1 Rev A CRN N/A
5. ASME Code, Section III, Division 1: 1980 WINTER 81 2 N/A(edition) (addenda date) (class) (Code Case no.)
6. Pump or'valve VALVE Nominal inlet size 2 Outlet size 2
Cm.U) (in.)7. Material: Body SA182, F31e Bonnet SA182,F316 Disk UNS99644, Bolting N/A
ALLOY 40 N/A
(a)* Cert.Holder's
Serial.No.
051003-1051003-2051003-3
(b)Nat'lBoardNo.
(c)Body
SerialNo.
. .. .
N/A E/Cs -lDLC
N/A ' EtC: lDBC
N/A' E/C: -lDLC-
. . . .
-
. , .
-
.
.
.
.
.
.
.
.
.
. . .
. .
:
.
. .
.
(d)BonnetSerialNo.
H/C: lDPXH/C: 1DPZE/C: IDPX
-. ,
(e)DiskSerialNo.
E/C: 07JR/C: 07JE/C: 14J
Supplemental information in form of lists, sketches, or drawings maybe used provided (l) size is 8 112 x 1I. (2) information in items I though 4on this Data Report isincludedon ech sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
W :.sm UC G o:r M ( W i; - -. . ,
(12/88) This form (E00037) may be obtained froi the Order Dept., ASRN!E 22 LAW DRIVE, Box 2300, Fairfield, NJ 07007-2300.
JIPAGE 4 OF in f
FORM NPV-I (Back - Pg. 2 of 2 )
Certificate Holder's Serial No. 051003
8. Design conditions 2500 psi 650 *F or valve pressure class 1730 (1)(pressure) (temperature)
9. Cold working pressure 4152 psi.at 100l F -- .
10. Hydrostatic test 6250 psi. Disk differential test pressure 4575 psi
11. Remarks: MATERIALS MEET ASME SECTION II EDITION- 1989 ADDENDA: NONE
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this pump orvalve conforms to the rules for construction of the ASME Code, Section III, Division 1.N Certificate of Authorization No. N-2797-1 Expires APR 20,2007
Date MAR 1 0 Mffi5 Name VELAN INC. Signed(N Cerdficate Holder) (a reprnsetnative)
CERTIFICATE OF INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler. andPressure Vessel Inspectors and the State or Province of QUEBEC and employed byREGIE DU BATIMENT o f QUEBEC have inspected the pump, or valve, described inthis Data Report on d /2.LOa , and state that to the best of my knowledge andbelief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASMECode, Section III, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty,expressed or implied, concerning the component described in this Data Report. Furthermore,neither the inspector nor 1s er shall be liable in any manner for any personal injury orproperty damage or a loss nf Ant kind arising from or connected with this inspection.
J.-P.FACHINETTI -QC 1381%CDatej'2..t- tO 2,,o S signed Commissions QUEBEC -
v- |(Authorized5spector) (Natt. Bd. (incdE9UMuhmDd not"'
(1) For manually operated valves only.
LPZAGE- 5 ,--oi -~ PJ]
FORM '/1 -ADM-080I.F02 REV 2 RTL ftA4.414-A
Form No. 1768
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NA.ME)
76 South Main Street - Akron, OH 44308
Date 12/1812004
Sheet 1 of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No.7 - . . . I
2(NAME)
Route 168 - Shinninnoort. PA 15077(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Route 168 - Shiooinaoort, PA 15077
Order #200057451Repair/Replacernent Organization P.O. No.. Job No.. eta
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date NIA(ADDRESS)
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, N/A Code Case
(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989
(c) Applicable Section XI Code Case(s): N/A
6. Identification of Components
Corrected. ASMIERemoved. Code
Name or NKam of Manufacturer National oard Other Year or StanpedComponent Manufacturer Serial No - No. Identificarion Built Installed (Yes or No)
Check Valve Mission B4582 N/A 2SWS-58 1976 Removed Yes
Check Valve Crane Nuclear D2567 NIA 2SWS-58 2003 Installed XYes
7. Description of Work Renlaced valve with spare.
8. Tests Conducted: Hydrostatic* l Pneumatic ElOther El Pressure
'Record test pessure and lerreerature
Nominal Operating Pressure 3 Exempt Elpsi Test Temp. OF
I ml
*1I
FORM 'A-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Code Data Reoort attached. Previous NIS-2 Data Reoort Nos: 1662. and 1455.Applicable Manufactures Data Reports to be attadced
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A
S igned n e d- 20 05Dat
Expiration Date N/A
1:..6 :la / /437 Date January 11 20 05%- Owner or Owner's Designee. Tile
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period -_________ to /- t - ,and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
In' S Commissions -7-* v r X3 ' -
Nationai Board. State. Prov4nce. and Endorseients
Date /-/o -- . 20 ____
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code, Section 111, Division 1
Pg.1 of 2
1. Manufactured and certified by CRANE Nudear. Inc.. 860 Remington Boulevard. Bolingbrook. IL 60440(name and address of NPT Cenfcate Holder)
2. Manufactured for First Energy Corporation. PO Box 345 Shippingport, PA 15077(name and address dt purdlaser)
3. Location of installation Long Term Storage Facility. Shiopingcort Hill Road. Shiopingport. PA 150s7- (name and address)
4. Model No.. Series No.. or Type 15 SEF-X04 D - Drawing C802839 Rev. *C CRN N/A
5. ASME Code. Section 111. Division 1: 1974 Summer 1974 3(edison) (addenda date) (cassl
N/A -(Code Case no.)
6. Pump or valve Duo-Chek Valve Nominal inlet size 30(I6,}
Outlet size 30(sn.)
7. Material:
(a) valve Body SA216 WCB Bonnet WA(b) pump Casting NIA Cover NIA
(a) (b) (c)Cert.- Nafl Body/Casing
Holders Board SerialSerial No. No. . No.
Disk SA216 WCSBolting N/A
(d)Bonnet/Cover
SerialNo.
Bolting SA479 TP 316A
- - (e)Disk
SerialNo,
02566 N/A D2568 NIA - D2570 8 02571(02567 N/A 02569 N/A- 02572 8 02573
Thi .ar .1007 .a beotie..mteOdrDptAM .2 a e .Bx200 aril.N 70-30
I',
I *II�JI LIILI�UI
.1
I tt1J 1 LltLt\ I NO -I /b4 P. I . I
FORM NPV-1 (Back) -- Pg. 2 of 2
Certificate Holders Serial No. 02566 & 02567
8 Design conditions 200'(pressure
Psi 300 'F or valve pressure dass(temperature)
ANSI 150 (1)
9. Cold working pressure 285 Psi at 100-F
10. Hydrostatic test 450 Psi. Disk differential test pressure 315 Psi
11. Remarks: P0 No. 7123964. Rev. 2. Item No. 1 SO No. 21871-al Valve ID: VCI-015-C-3Hinge/Stoo Pin Retainers, Ht #56457
CERTIFICATION OF DESIGN
Design Specifcatons ceiied-tr -- - Walter Joseph Parker. Jr. P.E. State PA Reg. No: 24003-E
Design Report certified by NMA P.E. State NWA Reg. No. N/A
CERTIFICATE OF COMPUANCE
We certily' that the statements made in this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code. Section IlIl. Division 1.
N Certificate of Authorizafion No.
Date 09/30103 Name
N-2899
CRANE Nudear. Inc.IN Crificsle Holder)
Expires Seplember24.2005
Signed
/ Jeme A A. , P.E.
CERTIFICATE Of INSPECTION
1 the undersigned. holding a valid comnmision issued by the National 8oard of Boiler and Pressure Vessel Inspectors and theState or Province of Illinois and employed by HSBCTof . Ftariffrd, cr lave inspected the pump, or valve. descnbed In this Data Report on 09/30t03and state that to the bett of my knowledge and belieft the Certificate Holder has constructed this pump. Or valve. ,n accodancewith he ASMIE Code. Section 111. D&vision 1;
By signing this cerilcato, nitol the inspector or his employer makes any wananty. expressed or inled, concerring theCarrponent desaibed In this Data Reapt. Furthmore. neither the inspector nor his employer sMall be liable in any manner forany personal Tnjury or property damage or loss of any kind arising frwn or connected with this Inspecton.'
Date o0930/03. Signed Commissions IL 932
VWNZe. HU 'A ht4 cwLdgred,5enmeM mmtt or prcm. A.nd no.
*->} (1) For manually werated valves only.
FORM %/2 -ADM-080 1.F02 REV 2 RTL # A4 .41 4-A
Form No. 1783
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C. Date 06/16/2005(NAME)
76 South Main Street - Akron. OH 44308 Sheet
2. Plant
(ADDRESS)
- Beaver Valley Power Station(NAME)
Route 168 - Shinnincoort, PA 15077
1 of 2
2Unit No.
Order #200079051(ADDRESS)
3. Work Performed By BV-Construction Services(NAME)
Rt. 168 - Shippingport, PA 15077(ADDRESS)
Repair/Replacerfent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Steam Vent (Class 2)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, -Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/ReplacementActivity 1989
(c) Applicable Section Xi Code Case(s)
6. Identification of Components
corrected. ASME.nCoted. Code
Name of Name of Manufacturer National Board Other Year or StanmedCormponent Manufacturer Serial No. No. Idntification Built lostalted (Yes or No)
Check Valve Enertech 11025 N/A 2SVS-8 1 2000 Removed Yes
Check Valve Enertech 11355 N/A 2SVS-81 2005 Installed Yes
7. Description of Work Replaced valve and inlet/outlet flange studs and nuts.
8. Tests Conducted: Hydrostatic* El Pneumatic* E Nominal Operating Pressure 3 Exempt E:Other fl Pressure psi Test Temp. O F
'Record test pressure and tenperature
I m l
FORM Y2-ADM-0801.F02 REV 2 RTL X A4.414-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Previous NIS-2 Data Report Nos: 1341, 784, 572. 364, 223,Ap;plicable Manufacturers Oata Reports to be attached
82. Reolaced inlet/outlet flanae 1" diameter: studs- Ht. #F955. and nuts- Ht.#M795.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed _ __ _ J
Expiration Date N/A
- !5v7/z Date JuIV 6 20 05-11 Co - % r'ner or Owner's Designee. Title * /
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in thisOwner's Report during the period /0 -/ f- °i to 9'-7-7-04C ° andstatethattothe
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
Luf Commissions .2J ',( /+A ---E-Ylnsrxos Signature Natirnal Boird. State. Province, and Endorserments
Date 20-6 I 20 a 4
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code. Section Ill, Division I
Pg. I of 2
1. Manufactured and certified by Enertech. A Div. of Curfiss-Wright Flow Control Corp., 2950 Birch.SL. Brea, CA 92821(name and address of N Certificate Holder)
2. Manufactured for First Energy Corp.; P.O. Box 3611; Akron, OH 44309-3611(name and address of Purchaser)
3. Location of Installation Beaver Valley Power Station; Route 168; Shippingport, PA 15077(name and address)
4. Model No.. Series No., or Type DRV-Z Drawing PD99824 Rev. B C None
5. ASME Code, Section 1ll, Division 1: 1974 S74 2 NoneNozzle Check (edition) (addenda date) (class) (Code Case no.)
6. Pump or valve Valve Nominal Inlet size 6 Outlet size 6tin. SA-564 Type 630 fin.)
7. Material: Body SA-105 Bonnet NIA Disk H1100 Bolting NIA
(a)
. Cert.Holder'sSerial No.
113541135511356
lb)
Nat'l
BoardNo.
NoneNoneNone
{c)BodySerial
No.
KZW-7752.KZW-7751KZW-7750
*Cd)
Bonnet
SerialNo.
NoneNoneNone
; (e)DiskSerial
- No.
KZO-7631KZO-7630KZO-7629
_
*Supplemental Information in form of litsts, sketches. or drawings may be used provided (1) size Is 8X x 11. 121 InformatIon In Items I through 4on this Data Report is Included on each sheet. (3) each sheet Is numbered and the number of sheets Is recorded at the top of this formn.
(1 2188 1 This form IE000371 may be obtained from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007-2300. It!.REPRL;T tS.3
FORM NPV-1 (Back - Pg. 2 of 2 3Ce 11354 t6ru
Certificate Holder's Serial No. 11356 _
8. Design conditions 1100 psi 560 orvalve pressure class 600 (1)(pressurel (temperaturel
9. Cold working pressure 1480 psi at 1000F
10. Hydrostatic test 2225 psi. Disk differential test pressure NIA psi
11. Remarks: Qty. 3, Enertech Project Number 810079
1!i'iii!
I.II
i:Iii
*l*1
I
II
i
CERTIFICATION OF DESIGN
Design Specification certified by Francis W. Gardner P.E. State PADesign Report certified by Ira J, Silverman P.E. State CA
_ Reg. no. 036614-E
- Reg. no. 23241
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code, Section 1I1. Division 1.M Cr.,+Mf.ct of A-thn-i-atl- Mn N-2826 FY>rNT10/11 /05.. an. ",.W0.G v- u"zvssotev^ rev.
Date g S Name EnetkadADiv.o(tissAMrH FowecontroCoip.(N Certificate Holder)
Signedta(authorized representative)
CERTIFICATE OF INSPECTION
I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors andthe State or Province of Califomia and employed by HSB CTof ConneCticut have inspected the pump, or valve, described In this Data Report on* {. 2b t & , and state that to the best of my knowledge and belief, the Certificate Holder has con-
structed this pump, or valve, in accordance with the ASME Code, Section 1II, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the
component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for
any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date Si 2 gned e Commissions _____
(Authorized Inspector (Nat'l. 8d. (incl. endorsements) and state or proy. and no.1
i
: I
AI
tq
il
ti
`7
1.
(1) For manually operated valves only.
III
-iAl
All
FORM V/2-ADM-0801.F02 REV 2 RTL t# A4.4 14-A
Form No. 1784
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYI As Required by the Provisions of the ASME Code Section XI
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date 06/17/2005
Sheet 1 of 2
2. Plant
(ADDRESS)
Beaver Valley Power Station - -(NAME)
Route 168 - Shipinaiport, PA 15077
Unit No. 2
Order #200079052(ADDRESS)
3. Work Performed By BV-Construction Services(NAME)
Rt. 168 - Shippinaport, PA 15077
Repair/Replacement Orgarnzation P.O. No.. Job No, etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4. Identification of System Steam Vent (Class 2)
5. (a) Applicable Construction Code Section III 1974 Edition, W74 . Addenda, N/A Code Case
(b) Applicable Edition of Section XI Utilized for RepairlReplacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Corrected. ASMERefoved. Code
Ne of Nam-e of Manufacturer National Board Other Year or StampedComponent Manufacturer Serial No No. Identifclation Built Installed (Yes or No)
Check Valve Enertech 10331 N/A 2SVS-82 1995 Removed Yes
Check Valve Enertech 11354 N/A 2SVS-82 2005 Installed Yes
7. Description of Work Replaced valie with snare and inlet/outlet flange studs and nuts.
8. Tests Conducted: Hydrostatic* El Pneumatic* a Nominal Operating Pressure N Exempt EOther E Pressure psi Test Temp. °OF
'Record test pressure and temperature
FORM I/z-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1665. 1451.1155. 785. 555. 365. 224. and 83.Applicable Manufacturer's Data Reports to be attached
Reolaced inlet/outlet flanae 1" diameter: studs- Ht. #F955. and nuts- Ht. #M795.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp. N/A
Certificate of Authorizatio N/A
Signed Inot Dat r
Expiration Date N/A
- -J '%_r Date Julv 6 20 05Owner or Owner's Designee. Title
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described In this
Owner's Report during the period / O - t/- 03 to ? 04x 7and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
Commissions ; /14 0 _57YVI s Signature
7- ae0
National Sdard. State, Province. and Endorsements
Date ,. 20 ° S_
FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code. Section iII, Division 1
Pg.l1of 2
1. Manufactured and certified by Enertech. A Div. of Curtiss-Wright Flow Control Corp.. 2950 Birch.SL. Brea, CA 92821(name and address of N Certificate Holder)
2. Manufactured for First Energy Corp.; P.O. Box 3611; Akron, OH 44309-361 1(name and address of Purchaser)
3. Location of Installation Beaver Valley Power Station; Route 168; Shippingport, PA 15077--(name and address)
4. Model No., Series No., or Type DRV-Z Drawing PD99824 Rev. B CRN None
5. ASME Code, Section I11, Division 1: 1974 S74 2 NoneNozzle Check (edition) (addenda date) (class) (Code Case no.1
6. Pump or valve Valve Nominal inlet sizi 6 Outlet size 6-in.) SA-564 Type 630 Un.)
7. Material: Body SA-105 Bonnet NIA Disk H1100 Bolting N/A
(a). Cert.Holder's
Serial No.
113541135511356
lb)
Nat'lBoard
No.
NoneNoneNone
I ..
Ic)BodySerial
- No.
KZW-7752.KZW-7751KZW-7750
Id)
BonnetSerialNo.
NoneNone.None
(elDiskSerialNo.
KZO-7631KZO-7630KZO-7629
I
*Supplemental Information In form of lists. sketches, or drawings may be used provided (1) size is 8. x 11. 21 Information In Items I through 4on this Date Report is Included on each sheet (3) each sheet Is numbered and the number of sheets Is recorded at the top of this forxn.
(12JB81 This form (E000371 may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield, NJ 07007-2300. REM~INTES93
I ml
FORM NPV-1 (Back -. Pg. 2 of 2 111354 th6u
Certificate Holder's Serial No. 11356 _
8. Design conditions 1'100 psi _6F or valve pressure class (1){pressurel Iternperaturel
9. Cold working pressure 1480 psi at 1000F
10. Hydrostatictest 2225 psi. Diskdifferentialtestpressure N!A psi
11. Remarks: Qty. 3, Enertech Project Number 810079
CERTIFICATION OF DESIGN
IDesign Specificaton certified by Francis W. Gardner P.E. State PA Beg. no. 036614-EDesgnSpefcaSoncetifedbyanE Rg.Ao._ 23241___Design Report certified by lrB J. Silverman P.E. State CA Reg. no. 23241
I!
1,
CERTIFICATE OF COMPLIANCE.1
We certify that the statements made In this report are correct and that this pump or valve conforms to the rules for construction
of the ASME Code, Section 1II. Division 1.N Certificate of Authorization No. N-2826 E 10/11/05
| Date '-<; Name Enetedh.ADivofCLtIss-Wtltt nowContrlcorp. Signed(N Certificate Holderi (authorited representativel
Eii
CERTIFICATE OF INSPECTION
; I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and
* the State or Province of California and employed by HSB CTOf Connecticut have Inspected the pump; or valve, described In this Data Report on
. -5 , and state that to the best of my knowledge and belief, the Certificate Holder has con-
structed this pump, or valve, in accordance with the ASME Code, Section 1II, Division 1.
By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or Implied, concerning the
component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for
any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
Date /2 .6°6lgned ± Commissions 6(Authorized Inspectort [Nat'l. Bd. Uind. endorsements) and state or prov. and no.]
(1I For manually operated valves only.
FORM 'A-ADM-0801.F02 REV2 RRTL # A4.414-A
Form No. 1786
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner _
76 South
2. Plant
F.E.N.O.C.(NAME)
Main Street - Akron, OH 44308(ADDRESS)
Beaver Valley Power Station
Date 06/16/2005
Sheet I of 2
Unit No. 2(NAME)
Ronte I6R - Shinninonort PA 15077 Order #200027180
3. Work Performed
Rt. I
(ADDRESS) Repair/Replacerrent Organizabon P.O. No.. Job No.. etc.
By BV-Maintenance Type Code Symbol Stamp N/A(NAME)
68 - Shippingport, PA 15077 Authorization No. N/A(ADDRESS)
Expiration Date N/A
4. Identification of System Chemical and Volume Control (Class 2)
5. (a) Applicable Construction Code Section III 1971 Edition. W72 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Ulized for Repair/ReplacementActivity_ 1989
(c) Applicable Section XI Code Case(s): None
6. Identification of Components
Corrected. ASME-_Rrmoved COde
Name or Nare of Manufacturer National Board Other Year or StampedComponent Manufacturer Serl No. No. Identification Built Installed (Yes or No)
Relief Valve Crosby Valve N56900-00-0034 NB-209 2CHS-RV382B 1976 Corrected Yes
Disc Insert Crosby Valve N90448-79-0318 N/A N/A 1996 Installed Yes
Nozzle Crosby Valve N90137-03-0338 N/A . Ht. #44532 1996 Installed No
7. Description of Work Replaced valve internals.. - -
8. Tests Conducted: Hydrostatic* L1 Pneumatic* LI Nominal Operating Pressure E Exempt ElOther LI Pressure psi Test Temp. °_ F
'Record test pressure and temperature
FORM '/2-ADM-0801.F02 REV 2 RTL iN A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Code Data Report attached. Previous NIS-2 Data Reoort Nos: 1528. 513.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp, N/A
Certificate of Authorization No. N/A
Signed 1(i& &At3
Expiration Date
Spe,, Date
N/A
Julv 8 20 05I Owner or Owners Designee, Title I
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have Inspected the components described in this
Owner's Report during the period /0of// . to 5/^ X 7^ - and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
t p c ' S atris ;'s Signature
Commissions / ~ -Y 6 4Z o & AL l gYNabonal Board. State, Province, and Endorsements
Date 7- F- 2, 20 °-q
RM M_ _--=t.~ ~ ~ ~ ~~~~~~~~~~~~~~~~~' 'C-~]- r.tss r);r~;7FBz7sa~ort2-~~r~E~asmCS
* Px- ' hti,<7rb~sbuzEz.Xdgr'id5.~iw;Si~7,l~~hii.:r>^DErwisy':3i.z IE; \ s+ :
B'-S ZX >7<__~bR~fw~f~t0~Et~tE_>_Pr *r,.xd==3....
, .I g1 'Utufrcturset ad cratad by r.w_ =,7 ' .' , , ., Z>:rn. nd Addrczn of N C:ertfis~te Hold=]. r'
... g ! Ductru crlUQU-JEI~r;E llHT Cl:. 'MIPiNGPORT,-:A-15677 ................................... :[ n . l~t::me and Address of Purcheser or Ow.-nor) ._
' 3. Location of In~tallation, SEAVER VALL PwOWER'STATION~_:m : . - - . ~MIt~me and Addres~sl: *.*)
. 4. S-C-_' S:,5690 i2EV.B: :1t(C-t.3 ., Mm:swiing No.l 1 (Year Built)
-n 5* JbASh1E SAk27jq PT=b 31 (; * 75,000;MfE latef.,al SP=6 r140.) - Tenzle Streng2th)
_6. -- _Nom. Thickness~in.) - Flin. D~esign 1Thickness-_-: S Din. ID ILength Ovenz~l I nch : :- g^:Inch . -- :n _
.. _.Design Pressura(M)II. - --. T~empercture,_
_ yidrostat.lc Tect 1%psig) at -- OF*_,_ ~(When applizablel-
S. Flzbrictead in sscczr.e2nce uwith Const. Spec.(DIv. 2 only) -Revaison__- Date-._
S. ASME Coda. Section l1l, Division 1-. *1971 _ WINT.R 1672 2 - _. =(Edition) :-(Addenda Date) (Class) (tCode Case No.) _
. 10. 5Remarks*_
I: 1. When n:pp; txE1e,- Certificate Itolders' dlata reports are attachedi for eacil item of this report:- .
. Part or Appurtenance Naijonal Part or Appurtenance National } }=at~ |Sril iNumber . .Bourd No. .. S6 ial Numbler . oerd No;' E
N umerical Order. Numerical Order
" | ~~~(2! l -,.
(B | {) - - 6)' - tiN |(S) _TIM _- i
(7)> * - - - (117 )'-!
(g } 9) _ (91 )(I iS ' (0) , M01 g- X
s r_ __ _
* tet E) N'.E.vv¢m
. i I
.. . *. . . .* .: ;
st7k=
. . ..* _
- -'1-. I . *- . .
.CLURFIFICITE OFHOJ' COMMlANCE
he=t~fy !h-At th ac teetsrr , t hlir rit-n a rierairra"o~' ms.n ths _2j) ISC M.,SERT:43tfa !0 he rv!c~ of construction of thea ASME02Code., Sac'djon Ill .. ....
D~te~j~~S~3~ Y22L~lU~f~g~bye
INV Cartificate _fAthorzatonN._N___T
Design specification certified by" H.P.LE9.ARDPS St&.. PA - Reg No.23 J8 .Design Report Certified byPE State - Reg No. -
-
_ _
,Signnaure not required- list name only.
mCERIFICATE OF SHOP INSPECTION .
'1. the undc;si4ned, hakring R valid cornmissicn Isvbed byothe National Board of 8ofer and Pressure VesserPInspectcrz and 1ili Stata or Province of ahna e and ernployed by Pte tuah~n uran1L 2A.oh a haVe inspected theso items'denccibed in tHis Data Raport on..
X~ eI J nnd st2to that to the best of rryknowledgo and belief. the*Ccrttficate holderhas ftabsicatad theso parts cr zppurtenances in accordtrnca with the ASM£ Code, Section Itl. Each par. htst dfhas bee'n authorLzed for stamplng on the date shown above. .-.BY dlnivg'thLs c=rtificate, neither the Inspector nor hWisemployir mAkes any wuarrant, expresced ornlip'uie~d,
3cc=Mnn,4J the compon-nt decribed in thts Dats Report' Furthermore, neither the Inspector nor Nus employer.ein any manner tcr any personal Injury or property dsmage ora loss of any kind arising from or
3connected with this Inspcition. . ,
* _ ,? i 0.5L<p..-- f.!re -xe,.allrsl:<NoU[lr-
v./ Y' ?
t Nat'l. Bd.. Statt, Prov. and No.)
FORM /z-ADM-080 IF02 REV 2 RTL # A4.414-A
Form No. 1788
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NAMIE)
76 South Main Street - Akron, OH 44308
Date 06/17/2005
Sheet 1 of 2(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippingport, PA 15077(ADDRESS)
3. Work Performed By BV-Maintenance(NAMED
Rt. 168 - Shippinaport, PA 15077(ADDRESS)
Order #200146518, 200114344Repawr/Replacement Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp NIA
Authorization No. N/A
Expiration Date N/A
4. Identification of System Main Steam (Class 3)
5. (a) Applicable Construction Code * Section IlI 1971 Edition, S72 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Corrected. ASNERerroved. Code
Name of Name of Manufacturer National Board Other Year of StampedComponent Manufacturer Serial No. No. Identification Built Insltalled (Yes or No)
Check Valve Enertech 10555 N/A 2MSS-19 1997 Removed Yes
Check Valve Enertech 11076 N/A 2MSS-19 2001 Installed Yes
7. Description of Work Replaced valve with spare.
8. Tests Conducted: Hydrostatic* E Pneumatic* El Nominal Operating Pressure 3 Exempt EOther E Pressure psi Test Temp. -- OF
'Record test pressure and terrperature
FORM '/-ADM-0801.F02 REV 2 RTL It A4.4 14-A
FORM NIS-2 (Back)
9. Remarks NPV-1 Data Report attached. Previous NIS-2 Data Report Nos: 1028, 938. 367. 200, andApplicable Manufacturees. Data Reports to be attached
094.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp N/A
Certificate of thor, Po0. N/A
Signed- :s
Expiration Date N/A
)Jar- i4 Js-r Date June 22 20 05- , %.. ChOwe r of Ownees Oesignee, Title A I .
CERTIFICATE OF INSERVICE INSPECTION
1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period i 0 -/1-Ct3 to -- / - 0 A, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificatd neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
czrs sg natureCommissions _ X A/
Nafional Boarr. State, Province. and Endorsernents
Date Gf -e1 Y2- , 20 0-17
FORM NPV-:1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*As Required by the Provisions of the ASME Code. Section III. Division 1
Pg.l of 2
1. Manufactured and certified by Enerted. A Div. of Curtiss-Wright Flow Control Corp.. 2950 BirdfVSt., Brea, CA 92821(name and address of N Certificate holder)
2. Manufactured for First Energy Corp.; P.O. BoX.3611; Akron, OH 44309-3611(nare and address of Purchaser)
3. Location of installation Beaver Valley Power Station; Route 168; Shippingport, PA 15077(name and addressl
4. Model No.. Series No.. or Type DRV-Z Drawing P098401 Rev E CRN NoneDrwn .lv CR
5: ASME Code. Section Ill. Division 1: 1971 S72- 3 Nonetedition) (addenda date) (dassl (Code Case no.1
6. Pump or valve Nozzle Chedc Valve Nominal inlet size 3_ Outlet size 36in.l lIn.l
7. Material: Body SA-105 Bonnet N/A . SA-479 Type 316 Boltin_ NIA____Bonnet____Disk BoltingN A
(alCort.
Holder's
Serial No.
1107511076
I
(b)
Nat'l
BoardNo.
None* None
(ci
Body.- Serial
No.
KEI-001KEI-002
(dl
BonnetSerial
No.
NoneNone
tel
DiskSerial
- No. .
- JKT-023JKT-024
* Supplemental information f form of Gsts; sketches, or.drawings may be used provided (13 size is 8YX x 1. i23 Information in items 1 through 4
on this Data Report is incuded on each sheet. (33 each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/881 This ftorm E000373 may be obtained from the Order Dept.. ASME. 22 Law Drive. Box 2300. Fairfield. NJ 070Oi-2300. KEPRtINT 6i
Ci'
.. i
FORM NPV-1 (Back -Pg. 2 of 2
Certificate Holder's Serial No. 11075 & 11076
8. Design conditions 1100 psi 560 F or valve pressure class 660(pressuel t(temperatuzel
9. Cold working pressure 1440 psi at 100F '.
10. Hydrostatic test 2175 psi. Disk differential test pressure 1600 psi
11. Remarks ()ty. 2, Enertech Job Number 24628V. ,
.
.
.
..
..
. .
CERTIFICATION OF DESIGN
Design Specification certified by Francis W. Gardner P.E. State PA Reg. no. 036614-EDesign Report certified by Ira J. Silverman P.E. State ReCA g . 23241
CERTIFICATE OF COMPLIANCE
We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for constructionof the ASME Code. Section lil, Division 1.N Certificate of Authorization.No N-2826 Ex 10/26/02
Date f9 0/° Name Enertech Signed(N Certificate Holderl (authorized representative)
CERTIFICATE OF INSPECTION
1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors andthe State or Province of Califomnia nd employed by Hartfod Steam Boiler Insp. & Insur. Co.
of Connecticut have inspected the pump. or valve. described in this. Data Report on
. Aj3e I , and state that to the best of my knowledge and belief, the Certificate Holder has con-structed this pump, or valve, in accordance with the ASME Code. Section 1II. Division 1.
By signin'g this certificate, neither the inspector nor his employer makes any warranty, expressed or implied. concerning thecomponent described in this Data Report. Furthermore, neither jhe inspector nor his employer shall be liable in any manner for
any personal injury or propert,' damage or a loss of any kind arising from or connected with this inspection.
Date34 Signed L7ommissions Z[l4'B4lAutdorzed Inspector) [Nal. Od. find. endorsemcntsl and state or ptov. ad no.]
(1I For manually operated valves only' .
FORM d'/-ADM-080L.F02 REV 2 RTL # A4.4 14-A
Form No. 1789
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NAMER
76 South Main Street - Akron. OH 44308(ADDRESS)
Beaver Valley Power Station
Date
Sheet
Unit No.
1 of 1
06/1712005
2. Plant 2(NAME)
Route 168 - ShipDingport, PA 15077(ADDRESS)
3. Work Performed By BV-Construction Services(NAME)
Rt. 168 - Shippingport. PA 15077(ADDRESS)
Order #200016207Repair/Replacement Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp NIA
Authorization No. N/A
Expiration Date N/A
4. Identification of System Recirculation Sprav (Class 2)
5. (a) Applicable Construction Code Seclion III .1971 Edition, S 72 Addenda. -Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
6. Identification of Components
Corrected. ASMERemnosd. Code
Name of Name of Manufacturer Naitonal Board Other Year or StampedComponent Ntanuraturer Seril Noa. No. Identification Buih Insiatltod (Yes or No)
Heat Exchanger Joseph Oat 2189-lA 890 2RSS-E21A 1976 Corrected Yes
7. Description of Work Pluqged and seal welded one tube.
8. Tests Conducted: Hydrostatic* a Pneumatic 5 Nominal Operating Pressure a Exempt 1Other El Pressure OFpsi Test Temp.
'Record test pressure and temperature
I-
FORCE /z-ADNM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 534. and 324. Plug(s): 5/8" diameter. Ht #D89473A.Applicable Manutacturers Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed/n12 i
Expiration Date NIA
i jI7- Date June 17 20 05I Owner or Owner's Designee. Title /
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period z 0 - // 0 °3 to 6 -eL°- Q , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
JA-V" J Commissions Aa'9Vo2 G/'°" Av&eNational Board, State. Province. and EndorsementsIns Signalure
Date -AZ 0 _ , 20 Osl
FORM '/i-ADNI-0801.F02 REV 2 RTL # A4.414-A
Form No. 1790
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C^(NAME)
76 South Main Street - Akron OH 44308
Date 04/27/2005
Sheet 1 of 1(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shipningport, PA 15077(ADDRESS)
Work Performed By BVPS Valve Team(NAME)
ShiDpingport PA 15077(ADDRESS)
3.
Work Order #200094915RepairtReplacement Organization P.O. No, Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Auxilliarv Feedwater (Class 2)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, - Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity...1j.98
(c) Applicable Section XI Code Case(s): !NLA-
6. Identification of Components
Correced. ASMERemoved. Code
Name of Name of Manufaturer National Board Other Year or StlnpedComponent Mamufauacwr SeialNo. No Idmifictraion Bail Installed (Yes or No)
Check Valve Enertech 11019 NIA 2FWE-99 2000 Corrected Yes
7. Description of Work Replaced inlet/outlet flange studs and nuts. -
8. Tests Conducted: Hydrostatic* El Pneumatic* a1 Nominal Operating Pressure E Exempt 1
Other n Pressure psi Test Temp. OF
Record test pressure and temperature
FORI Y/z-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1355. 966. 667. 507. Replaced inlet/outlet flange 7/8'Applicable Manufacturers Data Reports to be attached
diameter: studs- Ht. #P170 and nuts- Ht. #QJR.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp NIA
Certificate of Authorization No. N/A
Signed .- I& u)4.2 2J
Expiration Date N/A
°S11 '.r 4jsfm¢ate June 20 20 05Owner or Owner's Designee. Title
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in thisOwner'sReportduringtheperiod / -/f. ° 3 to b -?- ° - )J . andstatethattothebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwnees Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
xa-1v,-I omisinCommissions _z- I/.Inspec,% Signature National Board. Slate. Prownce. and Endorsements
Date (6 -4o 0 2., 20 A SK
FORM Y/z-ADM-080 .F02 REV 2 RTL # A4.414-A
Form No. 1791
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron. OH 44308
Date 04/27/2005
Sheet I of 1
2. Plant
(ADDRESS)
Beaver Valley Power Station(NAME)
Rntets IRA - Shinninnnort PA 15077
Unit No. 2
(ADDRESS)
3. Work Performed By BVPS Valve Team(NAME)
Shinninanort PA 15077
Work Order #200094914Repair/Replacemeent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date NIA(ADDRESS)
- 4. Identification of System Auxilliary Feedwater (Class 2)
5. (a) Applicable Construction Code Section IIl 1974 Edition, S74 Addenda, -- Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xi Code Case(s): NIA
6. Identification of Components
Correrted. ASMERemoied Code
Name of Name of Mamufactu-r National Board Other Year or SfampedComponent manufactuer scrial No. No. Identification Built Installed (Yes or No)
Check Valve Enertech 11021 N/A 2FWE-101 2000 Corrected Yes
7. Description of Work _Replaced inlet/outlet flance studs and nuts:
8. Tests Conducted: Hydrostatic* E Pneumatic* E Nominal Operating Pressure a Exempt 1Other El Pressure psi Test Temp. . .IF
Record test pressure and terPerature
I ,
FORM1 'Vz-ADNM-0801.F02 REV 2 RTL fI A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1356. 968. 669. 507. 371. and 214. Replaced inlet/Applicable Manufacturer's Data Reports to be attached
ntiflpt flnnri 7/R" diameter: studs- Ht ;P17 and nrtsi- Ht ViO.IR
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode. Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed J 0 20 05 r
Expiration Date N/A
tri , j4l - n 1 LIDate June 20 20 05- O.r or O:.r.et s Designee. Title I
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford, CT have inspected the components described in this
Owner's Report during the period / ° ' to 6O - = 0 Or, and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner s Report in accordance with the requirements of the ASME Code, Section Xi.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
1/, , Commissions :, Am0-4ctor's Signature National Board, State, Province, and Endorsements
Date 6- ,I - ., 20 C1 J
FORM l/-ADM-080 1.F02 REV 2 RTL # A4.4 14-A
Form No. 1792
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner
2. Plant
First Enerav Nuclear'Ooeratina Comoanm(NAME)
76 South Main Street - Akron, OH 44308(ADDRESS)
Beaver Vallev Power Station
; Date
3 Sheet
- Unit No.
1 of I
04122/05
A' 2 am" _ k-L,(NAME)
Route 168. ShiDoinaport, PA 15077 Westinahouse P.O. 7024829. . (ADDRESS)
3. Work Performed By BVPS/Spe((NAME)
Shiopinaoort. PA 15077
II
ReparReplacement Orgarization P.O. No.. Job No.. etc.
,ial Proiects Type Code Symbol Stamp NIA
Authorization No. NIA
Expiration Date NIA(ADDRESS)
4. Identification of System Reactor Coolant (01)
5. (a) Applicable Construction Code Section III 1971 Edition. S72 Addenda, See N-1 Form Code Case
(b) Applicable Edition of Section Xi Utilized for Repair/Replacement Activity 1989 Edition No Addenda)
(c) Applicable Section Xl Code Case(s)
6. tdentification of Components
Coffected. ASMERcwmed. Code
Name of Name of MWnulaZJer . Notional Bad Other Yea or StimComponent Mmnufaoru Sedal No. No. Ideatifcation Built Installed (VY or
_ _ _ _ _ _ _ _No)
Steam Westinghouse DMGT-1961 W-16598 2RCS-SG21A 1977 Corrected YesGenerator
7. Description of Work: Installed 28 Inconel 690 plugs (14 tubes).' Installed stabilizers in 13 tube locations.
Installed new gaskets on Primary manways & secondary side inspection ports.
8. Tests Conducted: Hydrostatic* El Pneumatic* a Nominal Operating Pressure 0I Exempt ElOther El Pressure psi Test Temp. F
Racwod test presstre and lemperabte
FORM /2-ADM-0801.F02 REV 2 RTL # A4.4 14-A-
FORM NIS-2 (Back)
9. Remarks Work Order (Tube Plugging) 200099004-Applicabte Manriaduxers Data Reports to be atdtaed
Machined four secondary side 2.0' inspection ports Dads (Shell side). Work Order 200099006
Replaced Bolt #1 on Inspection Port #2 and Bolt #4 on Inspection Port #3.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp NMA
Certificate of Authorization No. N/A Expiration Date N/A
Signed .LXu -sic 6- JADMoiwn or ownes Des U
Date April 26T 20 05
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by h',r.& c-r of
A gA -rTo d, C 7. have inspected the components descnbed in this
Owners Report during the period /0 -/1 - 63 to Y- > 7 0 , and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in thisOwner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected withthis inspection.
God _ Commissions 1/4 ?AY g4'2 °S pqInsr~sr National Boawd. State. Province, and Endorsements
Date z/- 2.- 7 - 220 0 S
FORM 'A-ADM-080 1.F02 REV 2 RTL # A4.4 14-A
Form-No. 1793
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner
2. Plant
First Enerov Nuclear Operatino Company(NAME)
76 South Main Street -Akron. OH 44308
Date
Sheet
Unit No.
04/22/05
I of 1
A Z 1A....a/ rLe
(ADDRESS)
Beaver Valley Power Station(NAME)
Route 168. Shinpinqport. PA 15077
- A 4 .,.
Westinghouse P.O. 7024829(ADDRESS)
3. Work Performed By BVPS/Spei(NAME)
Shippinaport, PA 15077
I
Repair/Replacement Orgauizabon P.O. No.. Job No.. etc.
:ial Projects Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date NIA(ADDRESS)
4. Identification of System Reactor Coolant (01)
5. (a) Applicable Construction Code Section lit 1971 Edition, S72 Addenda, See N-1 Form Code Case
(d) Applicable Edition ot Section XI Utilized for RepairlReplacement Activity 1989 Edition (No Addenda)
(e) Applicable Section XI Code Case(s)
6. Identification of Components
Correded. ASMRemoved. Code
Name or Name of i.AM5cmraue Natiotial Board Other Year or StampedCompoxnent Mauatucarer siaw NO. NO. Identification Bwit WntAfled (Yes or
Steam Westinghouse DMGT-1962 W-16599 2RCS-SG21B 1977 Corrected YesGenerator
7. Description of Work: Installed 68 Inconel 690 plugs (34 tubes). Installed stabiliizrs in 26 tube locations.
Installed new gaskets on primary manways & secondary side inspection ports.
8. Tests Conducted: Hydrostatic* 0 Pneumatic* D Nominal Operating Pressure E1l Exempt D
Other U! Pressure psi Test Temp. _F
Record lost presue ancd lesperaht
I El
FORM /A-ADM-080 1.F02 REV 2 RTL #A4.414-A
FORM NIS-2 (Back)
9. Remarks Work Order: (Tube Plugging) 200099007AppIicable Malacauvrs Oata Reports to be attadied
Replaced Bolts #2 & #3 on Inspection Port #1 and Bolt #2 on Inspection Port #4.
CERTIFICATE OF COMPUANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A Expiration Date N/A
Signed 4 A " 4( P pwn Date April 26TH , 20 05And w oraOnessg " ro ue,
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by AX C. r of
/ 4 0"% oe L. C 7-, have inspected the components descnbed in this
Owner's Report during the period / 0 // 0.3 to V- . 7 - 0 .S * and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expreased or implied, concerning the
examinations and corrective measures described in this Owner's Report Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
9 _e °- J Commissions 344V1d P3'7Ykrytors soiattn National Board. State. Provine, and Eixorsements
Date ., 20 °rDate .20 o�r
FORM Yz-ADM-080I.F02 REV 2 I RTL # A4.414-A
Form No. 1794
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner First Energy Nuclear Operating Companv Date 04/22105(NAME)
76 South Main Street - Akron, OH 44308(ADDRESS)
- Beaver Valley Power Station(NAME)
Route 168. Shippinqport, PA 15077
Sheet I of 1
2.- Plant -- Unit No. le ;Z ,dllE ,"C
Westinghouse P.O. 7024829(ADDRESS)
3. Work Performed By BVPS/Soel(NAME)
Shioninaport, PA 15077
7cia;f13mroects
Repar/Replacernent Orwanization P.O. No.. Job No.. etC
Type Code Symbol Stamp N/A
Auithnri7ztinn No. N/A
. _._ . . . _, _ _._
(ADDRESS)
Expiration Date N/A
4. Identification of System Reactor Coolant (Q1)
5. (a) Applicable Construction Code Section III 1971 Edition. S72 Addenda, See N-1 Form Code Case
(1) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989 Edition (No Addenda}
(g) Applicable Section XI Code Case(s)
6. Identification of Components
Corrected. ASMER--yedL Code
Nameof Name of Maufacturer National Board Oter Yew or. SampedCoponent Manufaacturer erSal No. No. [demriticadon Buitt . Installed (Yes or
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _N o)
Steam Westinghouse DMGT-1963 W-16600 2RCS-SG21C 1977 Corrected YesGenerator
7. Description of Work: Installed 14 Inconel 690 plugs (7 tubes). Installed stabilizers in 6 tube locations.
Installed new gaskets on orimarv manways & secondary side inspection ports.
8. Tests Conducted: Hydrostatice El Pneumatic* ED Nominal Operating Pressure 02 Exempt n
Other El Pressure psi Test Temp. OF
Record test pressure and temperature
I El
FORNI '-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Work Order (Tube Plugging) 200099010 .Appticabe Mantacdtis Data Reports to be attadid
Replaced stud 2CH15 on hot lea Primary manway & studs 2CCI & 2CC3 on cold lea Primary manway.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp N/A
Certificate of Authorization No. NMA Expiration Date N/A
104 lfl-wv�x slays pit,,,~t'q"-VSigned Date April 26TH 20 05(J Owner or Owners Desoiee. TiM
CERTIFICATE OF INSERVICE INSPECTION
I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by 1CA C 7 of
//9e4 7A °0 o' - C- 7-, have inspected the components described in thisOwner's Report during the period /0 toi 2 to '-/-, 7- , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
_ __ a1 Commissions Z4'' 1 'r• A.-3 YInse-o~ So e National Board. State. Province, ad Endorsements
Date /' AZ2- 20 ° -
FORM '/-ADM-080O.F02 REV 2 RTL # A4.414-A
Form No. 1795
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner FENOC(NAME)
76 South Main Street - Akron, OH 44308
Date - 7/5/05
Sheet 1 of I
2. Plant
(ADDRESS)
Beaver Vallev Power Station(NAME)
ShipDinoport, PA 15077(ADDRESS)
3. Work Performed By BVPS - Nuclear Construction(NAME)
Shirpinawort, PA 150077
Unit No. 2
I 2002R841RepairlReplacement Organization P.O. No.. Job No., eltc
Type Code Symbol Stamp NIA
Authorization No. NIA(ADDRESS)
Expiration Date N/A
-4. Identi-ication o'f System' Safety Iniection
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda. N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activityj1989E
(c) Appricable Section XI Code Case(s)
6. Identification of Components
Corrected. ASNMRemoved. code
Narneof Name of Manufacturer National Board Oter Year or StampedCompone"n Manufacturer Serial No. No. Identification . Built Insualed (Yes or No)
Snubber Pacific Scientific 23481 N/A 2SIS-PSSP006A _ Replaced No
Snubber Pacific Scientific 20930 N/A 2SIS-PSSP006A Replacement No
Snubber Pacific Scientific 24114 NIA 2SIS-PSSP366Y _ Replaced No
Snubber Pacific Scientific 19384 N/A 2SIS-PSSP366Y - Replacement No
7. Description of Work Reolaced snubber with spare for testing/refurbishment purposes.
8. Tests Conducted: Hydrostatic* El Pneumatic al Nominal Operating Pressure El Exempt EOther El Pressure psi Test Temp. ° F
'Record test pressure and temperature
FORM 1/2-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks The snubber was renlacedwith a used spare. No Code Data Reports are available.Applcable Manufacturer's Data Reports to be attached
Snubber are considered non-NF components (non-code).
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode. Section XI.
Type Code Symbol Stamp. NIA
Certificate of Authorization No. N/A Expiration Date N/A
Signed ae20 05Signedx Owner'a Designee. TiDate
CERTIFICATE OF INSERVICE INSPECTION
1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /0 11 '-3 to 9-D1 - and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
Lnsp73gnatureCommissions A, ,/ Ab 3 Y
National Board. State. Province. and Endorsemnents
Date , 20 _ -
FORM '/2-ADM-080.F02 REV 2 RTL # A4.414-A
Form No. 1796
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner FENOC(NAMtE)
76 South Main Street - Akron. OH 44308 -
-Date 7/5105 - - -
'Sheet I I ' of ' ' 1
2. Plant
(ADDRESS)
Beaver Valley Power Station(NAME)
ShinoinaDort. PA 15077
Unit No. 2
200028814(ADDRESS) RepairIReptacement Organization P.O. No.. Job No.. etc.
3. Work Performed By BVPS - Nuclear Construction Type Code Symbol Stamp NIA(NAME)
Shiopingport. PA 150077 Authorization No. N/A(ADDRESS)
Expiration Date N/A
4. Inertlficafion of System Main Steamr
5. (a) Applicable Construction Code Section IlIl 1971Edition, W72 Addenda, N/A Code Case
(d) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989E
(e) Applicable Section Xl Code Case(s)
6. Identification of Components
Correced. ASMERemoved. Code
Naneof Name of Marnuiaturer Nationl Board Otlher Year or 'StampedComponent Manufacturer Serial No. No. Identification Built InstaIted (Yes or No)
Snubber Pacific Scientific 3705 N/A 2MSS-PSSPOO6 Replaced No
Snubber Pacific Scientific 17005 N/A 2MSS-PSSP006 Replacement No
7. Description of Work Replaced snubber with spare for testing/refurbishment purooses.
8. Tests Conducted: Hydrostatic* El Pneumatics E Nominal Operating Pressure El Exempt ElOther El Pressure _ _ psi Test Temp. OF
'Record test pressure and temperature
FORM 'Y-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks The snubber was replacedwith a used spare. No Code Data Reports are available.Applicable Manufacturer's Data Repo"ls to be attached
Snubber are considered non-NF components (non-code).
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp_ NIA
Certificate of Authorization No. N/A Expiration Date N/A_7 . .. J. _. ..*-,** _ _= -
Signed / Date .20 _ __
Owner or Owners Designee n.e Wc)-
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectorsand the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in thisOwner's Report during the period /b -I/ * to 4-- 7- 6X and state that to thebest of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning theexaminations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employershall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
I dor's SgnatureCommissions , A, - 4 A+ : 1 Y/
National Board. State. Province. and Endorsements
Date , 20 ° -Date 20 O
FORM '2-ADM-0801.F02 REV 2 RTL # A4.414-A
Form No. 1797
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section XI
1. Owner FENOC(NAMvtE)
76 South Main Street - Akron. OH 44308
(ADDRESS)
2. Plant Beaver Valley Power-Station'(NAME)
ShipDingport, PA 15077(ADDRESS)
3. Work Performed By BVPS - Nuclear Construction(NAME)
Shippingport. PA 150077(ADDRESS)
Date 7/5/05
Sheet I - of I
Unit No. 2
Repair/Replacemeent Organization P.O. No.. Job No.. eta.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
4. Identification of System Reactor Coolant
5. (a) Applicable Construction Code Section III 1971Edition, 2 Addenda, N/A Code Case
(0 Applicable Edition of Section Xl Utilized for Repair/Replacement Activityj198
(g) Applicable Section Xl Code Case(s)
6. Identification of Components
I
iI.- I
i
IIi
iIi
i
.o.rceed. A.SaERetnovcd Code
Name of Name of Manufacturer Nationul Board Other Year or SianpedComponent Manufacturer Serial No. No. Identification Built Installed (Yes or No)
Snubber Pacific Scientific 17005 N/A 2RCS-PSSP035X _ Replaced No
Snubber Pacific Scientific 3699 - N/A 2RCS-PSSP035X Replacement No
7. Description of Work Replaced snubber with spare for testing/refurbishment purposes.
8. Tests Conducted: Hydrostatic* M Pneumatic* M Nominal Operating Pressure El Exempt MOther E Pressure _ _ psi Test Temp. OF
Record test pressure and temperature
FORM 'Yz-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks The snubber was replacedwith a used spare. No Code Data Reports are available.Applicable Manufacturers Data Reports to be attached
Snubber are considered non-NF comronents (non-code).
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp_ NIA
Certificate of Authorization No. NIA Expiration Date NIA
Signed g a q. g Date _ _ _ _ _ _ 20 OSOwner or Owner's De nee. Title
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in thisOwner's Report during the period / 0 I 0/ to ______________*and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
inspec sgnatureCommissions ..L , I,..' , : A '
National Board. State, Proance. and Endorsements
Date ., 20 D XJDate .20
FORM '/2-ADM-0801.F02 REV 2 RTL # A4.414-A
Form No. 1798
FORM NIS-2 OWNER'S REPORT FOR REPAIRSIREPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron. OH 44308
Date
Sheet
06/15/2005
1 of 1(ADDRESS)
Beaver Vallev Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippingport, PA 15077(ADDRESS)
3. Work Performed By BV-Maintenance(NAME)
Rt. 168- ShiDpinaport. PA 15077
Order #200022184RepairIReplacement Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A(ADDRESS)
4.
5.
Identification of System Fire Protection (Class 2)
(a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, N/A Code Case
(b) * Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section Xl Code Case(s): None
Identification of Components6.
Corrected. ASMERemroved. Code
Nanmeof Nom of Manufacturer Natonal Board Other Year or Szan' edComponent Manufacturr Serial No. No. Identification -- Built Installed (Yes or No)
Check Valve Atwood & 27-13540 N/A 2FPW-761 1980 Corrected . YesMorrill
7. Description of Work Replaced stuffing box hex nuts.
8. Tests Conducted: Hydrostatic* E Pneumatic* El Nominal Operating Pressure El Exempt |
Other E Pressure psi Test Temp. OF
*Record test pressure and temperature
FORMI '/2-ADM-0801.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report No. 1085. Replaced 1/4" diameter nuts: Ht. #R268.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xi.
Type Code Symbol Stamp N/A
Certificate of Authorization No. N/A
Signed - i )Expiration Date
-______ Date
N/A
July 1 I 20 05Owner or Owner's Designee, rtte I
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /O-//-O B to V-0 Z 7.- 0 , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code. Section XA.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
__ _ _ _ __ _ _ _ _Commissions Go a' ' vCtnsp' Signature National Board. State. ProrAnce. and Endorsernents
Date 7- f- 2, 20 ° Jo-
FORM 'A-ADNI-0801.F02 REV 2 RTL # A4.4 14-A
Form No. 1799
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl
1. Owner F.E.N.O.C.(NAME)
76 South Main Street- Akron, OH 44308
Date 0412912005
Sheet 1 of 2
2. Plant
(ADDRESS)
Beaver Valley Power Station(NALME)
Route 168 - Shipopinawort. PA 15077
Unit No. 2
Work Order #200148005(ADORESS)
3. Work Performed By BVPS Construction Services(NAME)
Shinoinnport, PA 15077(ADDRESS)
Repair/Replacernent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date , N/A
4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda, N/A Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989 -
(c) Applicable Section XI Code Case(s): N-416-2
6. Identification of Components
Corrected. ASMERemoved. code
Name of Name of M1anmifacturer Nationaf Board Other Yeat or SaampedComponent Manufaclurer Serial No. No. ldeni fication Built Installed (Yes or No)
Gate Valve Walworh Al 103 N/A 2SWS-I230 1978 Corrected Yes
7. Description of Work Repaired pinhole leak in body of valve next to inlet piping weld.
8. Tests Conducted: Hydrostatic* Pneumatic* E Nominal Operating Pressure Z ExemptE
Other L Pressure psi Test Temp. OF
'Record test pressure and temperature
FORM '/2-ADNI-0301.F02 REV 2 RTL # A4.414-A
FORM NIS-2 (Back)
9. Remarks NPV-1 Data Report attached. Apparent Microbiological influenced corrosion pinhole leakApplicable Manufacturer's Data RepOrts to be attached
next to inlet weld was ground open and weld reDaired. ReDlaced inlet/outlet flange studs (P.O.
47059254. Ht. #K863) and nuts (P.O. 47052718. Ht. #P176) Previous NIS-2 Data Report No.
1444.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section Xl.
Type Code Symbol Stamp NIA
N/A
June 21 220 05
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period / 0 -//- 23 to 6 C,2 V/-OJ , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the
examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
_ _ __ , _ Commissions _______________d __d ___~;%ors signatiure, National Board. State. Province. and Endorsements.
Da te Dt (a , V- , 20 0 S-
FORM Nazi MtANUFACTIURERS'; DATA REPORT. FOR NUCLEAR PUhMPS.OR VALVES7- . .~' (AsRoerWdby dfie Pro-isocisc th~e ASMEd4Sn In. DN:;11.,. B
-: -
1. Manufactured bf;wlo~~c~tviocfpi- liel e-ess 73
'L of :1i ," BiE'd;4 aver,,,, :Poa bv-,on W~~t2 ;' ;^;,_ .
I<ff a n * 4 . ** % Q A Ivl e e a e ' - v - - ; t<ml4 M *.-ins ,-~l I~~cSiX,
orl Ty . C.. ........ i. <- 1%- *:*E**;-Sum -4@19; s -'Ts> se.^..>f . ;l >, L4a~ "rI- -sX>-t*2 >¢ <
\ *(1 *!- ' ,-H.;e ~s,.,.~ _ ., * ' *- - :;'is;'\ 4 4 < - .<. eo . - ^- 9 t-.l : _ .
- .. l -* t ae- -- e -; v -s. - ..............-. -.-9* R ................ ^e -.;.5'0945 ,- 2 ,^- .. 8 -::*-.* :*-::¢;}X -]* .-¢ ;:'.1) ,- .@*sa5
;- --. . .8) - r,:. ., *: ': -;-- '- :;' " ^ *, ,ljo, -; <4 ,@. .; @.............. .i_> ... >.*i a- ....... .Jtit~zte '.s t- . .,;.p w i--;.ri;-.i!S.........-...........*,*
S.
4 . 6 ffi
*o
i4|*@5.oa6D-
:'.asZ.,, ... s
: . x,, .. . x :.
An',,
.<;: .- ;? . .
f es*ay *9
:- .X-,, ,.X.
. :.f
.. An',*; ::4 ' eSt.'
' . .
' ' :.,' S>.
'''; <'a,\ .:
'.W' X.- .
F ' .
'
,ve.W;; S
. .
:s:
. 6.
*7.S.
Da'sgn.Condtions- p .F or Vafi P *sue fags -A
.Cold Worldng Pressurvh 27 5- at I 1Wf *-Preiisure Retaininghoe.:*::.**-........' -. .*--.-*.*.*-. .. :-
MarikNo . .-. Mateiteal pec.No-. .; | : . Manufacturer .... _|-Hae*
(Al Carti gs * * ~ ;. .- ~ ~ *1* *Bodv--. - SA-351 C:F_8 .. ... -,W No -: |aloth-/Aloo-vc |.516D.Bonnet : .SA-3 5 1 CF8 . >alwor-th/A l oc .'33&9D . :%.
D~~~~~I <e!;-C Sl 4h:;., C. lwort /A .oce - . .: . -, .... --....... ..-..E*...
*b .F.or .-- f "' ;. " .', *' ' ......n. " 1 ' : .'; s:
L . _ L * X v-A*.- -7
An*.:
< w :.:
* * *: It'sA
w
* * @ §6* *:
. . * *
.:
{l) For manually operate -srsonly.'
*Supplzmental Shiiti in fOirM Of lilts. skcetches Olt drawings maY be' used provided {1jsize is .1 - x2 X.1 1 ' (21 inforrnation inEtents ~ ~ ~ ~ ~ ~ ~ ~ ~ ~~* 12an or'hi8t at sicue^nec' e.and (3) tach sheet is snurrbered and nismber of shedtS
is recorded at top Of Lhis fonT.
(Irm ~ - This toam (C00037) t' obntd f romth s Otd dfr Oeet., ASM E. 34cS E. 47 St.- Ne York: N.Y. I CO1I2; . .y
--------- - -- L-M-L
-::1ss *! .-
X,..--'W. :W :,
H .<
.-.7-. .
.:: :..
::,
,....:% .
..! ' . . > 7 ,
' ' '..
-"'-;'-N
.N \,.-'
ar 4.Matirnal Spec. No....: Manufic-uier. .1 . ea
.. IA-194. Gr.-8--.-B
-
--.. . *.-. .** . . . .;f. -. .i,... 1
Oihe, 1
S ...
SA'j8~t-:T --?30,;Camo1.-
I ~ . ___ _____ ____
.:..r
� I
. . FICATE OF COMPUANCE ;. :.
Wo rdty that the statements made in this report are correct and that this pump, or vlve, conforms to the rules of,construction of the:ASME Code for Nuclear Power Plant Comoonents. Section III. Div.. l. Edon .1971Addenda Winter 1972 .Code Case No; 1672 ;Otj At -7I. JS5
Signed Walworth Com DanV/Alovco Parnt d A, Manufacurer ' .. Tru 1gMgrr.A.
Our ASME Certificate of Authorization No. 6-2076 Jto use the ' N symbot expkres 4-7-81, ;, , INF) lute
CERmnFICATION OF OESIGN
Desig~infimeaison on rile -a' Waiworth Companv/Alovco Plant .Stress 8nyslsreport( iC-io..y) ant ir it . f :..Nptr reaU iredt : . .
Fark:A.gooalan j.-^, Deisn peatcit onscertlf~ied by 1 ; aucA, ;o alni :.PE S~o Pa :s;R No.; -- 21966 -E ,e .;
Stress analyss'cenifid by (1) Vpt rpioirp-PE SUta' Reg. No.
(1) Signature not required. Ust 'iamne 'onj '
,JM. OF SHOP , .US .ECTIO
; the undersigned. holding a valid commis lan. issuedb' the Nadtonal Board of Boiler and Pressure Vessel Inspectors.and the Stitel6'r Pr'oAlnce 6f ' I3>sg N .wdTp fi V and emoloyed by" .' T45B T COQaf artford Ct. .-h, inspected the' pum'p; or. valve, described in this Data Report on
' ~ :7~ *. ' 19ZL and sate that to the best of ry knovredge ind belief. the Manufacturer has con--Uucted this ump. or valve. in accordanci wth the ASME Code. Sectlon Ill.
By signing this cerificate neither the Inspector nor his employer makes any warranty. expressed or implied. concerningthe equiprient described in this Data Report Furthermore. neither the Inspector nor lis employer shall ba liable in anymanner for any personal uinry or prperty damn¶age or a iot of any lbd arising from or connected with this inspecslon.
Date a. i9,&: ' ' '-/*fi ' " f. -- 'Commissions . - -71
. . Y . . DU-4-1.. I-.
FORM %-ADM-080 .F02 REV 2 RTL # A4.414-A
Form No. 1800
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xi
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron, OH 44308
Date
Sheet
06/18/2005
I of I(ADDRESS)
Beaver Valley Power Station2. Plant Unit No. 2(NAME)
Route 168 - Shippincport, PA 15077(ADDRESS)
3. Work Performed By BV-Maintenance(NAME)
Rt. 168 - Shipninqport, PA 15077
Order #200148055.200063831Repair/Replacemnent Orgonuzabon P.O. No., Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date NIA(ADDRESS)
4. Identification of System Reactor Coolant (Class 1)
5. (a) Applicable Construction Code Section III 1971 Edition, W72 Addenda, NIA Code Case
(b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 1989
(c) Applicable Section XI Code Case(s): None .
6. Identification of Components
Corrected. ASMERemnoved, Code
Name of Name of Manufacturer National Board Other Year or SturpedComponent Manufacturer Serial No. No. Identification Built Installed (Yes or No)
Safety Valve Crosby N56963-01-0010 N/A 2RCS-RV55IA 1980 Removed Yes
Safety Valve Crosby N56963-0009 N/A 2RCS-RV55 I A 1976 Installed Yes0009
7. Description of Work Replaced valve with spare and inlet flange studs and nuts.
8. Tests Conducted: Nydrostatic* El Pneumatic* El Nominal Operating Pressure E Exempt
Other O Pressure psi Test Temp. OF
*Record test pressure and tenperature
* I - l
FORM '/2-ADNI-0801.F02 REV 2 RTL Mf A4.4 14-A
FORM NIS-2 (Back)
9. Remarks New inlet 1-3/8" diameter studs- Ht. #J361, nuts- Ht. #E473. Previous NIS-2 Data ReportApplicable Manufacturers Data Reports to be attached
Nos: 1330, 846, 346. 202, 061. 053, 044. Valve S/N N5693-00-0011 was installed Per Order
#200063831 but leaked-bv durinq startup of the plant and was replaced Per Order #200148055
with S/N 5693-00-0009.
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp,p CN/A
C6rtificate of Authorization No.
Signed@5
N/A Expiration Date N/A
Signed Date June 28 .20 0Date June 28 , 20 O0ix- Owner or Owner's Oesignee. rite
CERTIFICATE OF INSERVICE INSPECTION
I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owner's Report during the period /0 -//-O3 to '/-S 7e - 0 , and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the
examinations and corrective measures described in this Owner's ReporL Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
_4Q����/. Commissions ..-L-Commissions 27 / V,In<-s Signature Natlonal BoaFd, State. Promnce. and Endsrsernents
Date 7 - S-- -20 0 C
FORM 'A-ADM-0801.FO2 REV 2 RTL # A4.1414-A
Form No. 1804
FORM NIS-2 OWNER'S REPORT FOR REPAIRS/REPLACEMENT ACTIVITYAs Required by the Provisions of the ASME Code Section Xl :
1. Owner F.E.N.O.C.(NAME)
76 South Main Street - Akron. OH 44308
Date 07/06/2005
Sheet I of I{ADDRESS)
Beaver Valle_ Power Station*2. Plant Unit No. 2(NAME) I _
Route 168 - Shinninnnort- PA 15077(ADDRESS)
3. Work Performed By BVPS-Maintenance(NAME)
Rt. 168 - Shippinaport, PA 15077(ADDRESS)
Order #200055515Repair/Replacernent Organization P.O. No.. Job No.. etc.
Type Code Symbol Stamp N/A
Authorization No. N/A
Expiration Date N/A
.4. Identification of System Service Water (Class 3)
5. (a) Applicable Construction Code Section III 1974 Edition, S74 Addenda, N/A Code Case
(b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 1989
(c) Applicable Section XI Code Case(s): N/A
6. Identification of Components
Corrected, ASMEPaeoveo4 Code
Name of Name of Manuficturer National Board Other Year or stampedConponent NIanUcturer Serial No. No. Identification Built Insalled (Yes or No)
Check Valve Crane Nuclear D0939 N/A 2SWS-57 2002 Removed Yes
Check Valve MissionfRW B4584 N/A 2SWS-57 1976 Installed YesInc
7. Description of Work Replaced valve with snare.
8. Tests Conducted: Hydrostatic* l Pneumatic* E Nominal Operating Pressure Z Exempt ElOther El Pressure psi Test Temp: . .OF
'Record test pressure and temperature
FORM V/-ADM-0801.F02 REV 2 RTL # A4.4 14-A
FORM NIS-2 (Back)
9. Remarks Previous NIS-2 Data Report Nos: 1682, 1443. Installed spare from 2SWS-106 location.Applicable Manufacturer's Data Reports to be attached
CERTIFICATE OF COMPLIANCE
I certify that the statements made in the report are correct and that this conforms to the requirements of the ASMECode, Section XI.
Type Code Symbol Stamp. N/A
Certificate of Authorization No. N/A
Slgnd nk e d~ _-v-llo
Expiration Date NIA
Dt 6$CjAI /!' Date July 6 I 20 05Owner or Owner's Designee, Titce
CERTIFICATE OF INSERVICE INSPECTION
1, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors
and the State or Province of Pennsylvania _ and employed by HSB CT of
Hartford. CT have inspected the components described in this
Owners Report during the period - /- 0L°3 to 4-1- A7- 0- and state that to the
best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this
Owner's Report in accordance with the requirements of the ASME Code, Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the
examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer
shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
-,I29 -P "cor's Signature
Commissions -r Al g°8 -V ANat'onal Board, State. Province. and Endorseerents
Date 7-6 20., 20 ° J