BRIDGE CONDUIT SYSTEM
S&B DIV
S&B DIV
S&B DIV
PLAN
Notes:
Scale: 1" = 1'-0" unless otherwise shown. BCS-31A
BC
S-31
A
Abutment Pier tMovement
Longitudinal
Type
Detail
/
Typ.
Typ.
‰
„
L 2 x 1• x ‚
2 each side
‚" o x 4" stud
JUNCTION CHAMBER FRAME
„" ty
p.
PL ‚ x 10ƒ
ƒ"
4ƒ
"
12"
4ƒ
"
10"
4…" 4…" ƒ"
•"
ƒ"
8"
L frameC
Typ.
ƒ"
ƒ"
ƒ"
/12 required
‚" o screw,
countersink for
Drill, tap and
Bar … typ.
gasket or equal
elastomeric
One piece „"
L 2 x 1• x ‚
Scale: 3" = 1'-0"
‚" o f.h. bronze
or stainless
steel screw typ.
/
8"
•"
•"
•"
•"
ƒ"
Date Plan No. Sheet No.Designed: ...........
Drawn: ................
Checked: ............2018, Commonwealth of Virginiac
No. Description Date
STRUCTURE AND BRIDGE DIVISION
COMMONWEALTH OF VIRGINIA
DEPARTMENT OF TRANSPORTATION
Revisions
ROUTE
FEDERAL AID
PROJECT ROUTE PROJECT
STATE SHEET
NO.
VA.
STATEROUTE
FEDERAL AID
PROJECT ROUTE PROJECT
STATE SHEET
NO.
VA.
STATE
STRUCTURAL ENGINEER
RICHMOND, VA
VDOT S&B DIVISION
bcs31a.d
gn
.
railing detail sheet (CPSR-series).
05-03-2018
Bars RG0403 and RG0404 are detailed and accounted for on the
o
o
rail post clears the conduit system and the light pole base area.
Location of light pole shall be adjusted such that anchor bolts of
grounding materials that conform to Section 238.
Conduit shall be grounded in conformance with Section 700 with
for installation.
The Contractor shall determine all dimensions and details necessary
10 F temperature drop or rise respectively by t.
The amount of movement shall be increased or decreased for every
and shall be adjusted in accordance with manufacturer's requirements.
expansion and deflection fitting calculated for placement at 60 F
Longitudinal movement is the maximum amount of movement of the
anchor bolt shall be supplied with 3 washers and 3 nuts.
galvanized. 4" at each end of anchor bolt shall be threaded. Each
and washers shall conform to Section 226.02(c) 2. and shall be hot-dip
Anchor bolts shall be high-strength anchor bolts. Anchor bolts, nuts
price bid for railing.
Cost of Bridge Conduit System and anchorages shall be included in
tion, in accordance with ASTM A123.
Junction chamber frame and cover to be galvanized, after fabrica-
observed.
clearances for the installation of deflection fittings shall be
Close adherence to the manufacturer's requirements in regard to
Cut or bend bars to clear junction chamber.
Class __.
All reinforcing bars shall be Corrosion Resistant Reinforcing Steel,
ABUTMENTS
10"10"
/5" o opening
min. min.
PIERS
45o
4†"
CONDUIT LAYOUT
A
B
/
A BTop of slab
steel drain pipe
1" o galvanized
12"
6"
1 2
46
7
8
13
4 3 5 3 9 3 4
12
11
3
(Virginia Alternate Pier)
integral backwall
Face of
10
Not to scale
/
/
/
/
/o
1
5
6
7
8
9
10
11
2
4
3
12 /o
conduit to junction box
Bell fitting or bushing to connect
2" o 45 9•" R nonmetallic elbow
2" o 45 13" R steel elbow
Metallic coupling
Metal expansion fitting
conduit to junction box
locknut and bushing to connect
1" o metal conduit - Furnish
junction chamber
8" x 8" x 1'-4" formed
2" o pipe cap
deflection fitting
Metal expansion and
conduit to metal conduit
Adapter to connect nonmetallic
2" o metal conduit
Nonmetallic coupling
2" o nonmetallic conduit
13
deck slab
Top of
6 - RT0601
to be furnished by others
Base plates and light poles
Face of rail2'-10"
FL0401
Top of sidewalk
SECTION B-B
1'-10"
6" 6"1'-6"
2'-6"
/
C
C
1'-
10"
1'-
10"
10"
6"
6"
2" o conduit/
RT0601
1" o metal conduit/
Face of rail
of light pole
6" min. at bot.
1'-
6"
with FL0402
6 - FL0503 spaced
chamber
L formed junction
anchorage and
L light pole
6 - FL0402
with 6" o hole
in center
/
2ƒ"
projection
4" anchor bolt
to drain
Slope
FL0503
FL0402 and
1'-
9"
min. la
p
FL0404
SECTION A-A
RL04 series shown.
RG0404
RG0403 and
2'-
0"
Face of rail
12"
1•" cl. min.
RL04 series
sidewalk
Top of
RG0403
RG0404
rebars in deck slab not shown for clarity
Reinforcement in sidewalk and transevese
slab bars
Longitudinal
L conduitC
/
1" Projection
steel drain pipe
1" o galvanized
L conduitC
chamber
L formed junctionC
/projects 4" above concrete
1" o metal conduit
8"
7"
5"
Central Office.
is on file in the
standard drawing
sealed and signed
A copy of the original
May 03, 2018
On the date of
Lic. No. 033572
Junyi Meng
Sealed and Signed by:
FL0401 and FL0404
.
1'-
7"
FL0503
Mark Length Location
2"
FL0401
FL0402
REINFORCING STEEL SCHEDULE
No. /
Dimensions in bending diagram are out-to-out of bars.
Light base
Light base
Top of deck slab
FL0503 Light base3ƒ"
4ƒ"
Pin oSize
#4
#4
#5
#4
#6
typ.
4•"
RG0403
RT0601
1'-4‚"
5'-1"
6'-4"
6'-8"
1'-7"
FL0402
4•"
FL0401
2'-
5ƒ
"
2'-1‚"
FL0404
2'-
5ƒ
"
2'-1‚"
2" Light base#4 5'-8"FL0404
Concrete pedestal
3"
#4RG0404 Concrete pedestal.
1'-
11ƒ
"
1'-
2"
PL 1 x _ x _
@ _" o bolt circle
_ - _" anchor bolts
STANDARD BCS-31A: NOTES TO DESIGNER
PART 3
DATE: 03May2018
SHEET 2 of 3
FILE NO. BCS-31A-2
BRIDGE CONDUIT SYSTEM FOR LIGHTING WITH CPSR SERIES RAILING
WITH SIDEWALK
NOTES TO DESIGNER:
Standard is to be used only when lighting is installed as part of project and used with the Railing standard CPSR series with sidewalk and when all railings are attached on the traffic side of the rail posts. Terminal wall for the railing is located on abutment or U-back wing.
Access to junction chamber is from the inside of the railing concrete pedestal face on the traffic side. Light pole anchorage is designed in accordance with AASHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires and Traffic Signals, 4
th Edition (2001),
including Interim Specifications. Design requirements are as follows:
Pole mounting height: 40 feet Pole size: avg. 6” O.D. (8” O.D. on base) Bracket arm: length: 6’-0”; weight of truss: 15 lbs. Size of luminaire: 3.2 sq. ft. Weight of luminaire: 81 lbs. Bolt circle for anchorage (base plate): 11” diameter thru 16” diameter
Light pole anchorage is to be located no closer than 4 feet to abutment (backwall) or parapet joint. Show location of centerline of light pole anchorage(s) on appropriate plan sheet, normally plan of deck slab. The standard provides for adequate pole clearance for placement of the rail on the front or back face of the post. Size of junction chamber: 8” x 8” x 1’-4”. Conduit size: 2” diameter. Show location and size of conduit(s) on transverse section sheet. Show location of junction chambers on appropriate plan sheet, normally plan of deck slab. For larger conduits the bend radius in the conduit (steel elbow and nonmetallic elbow) and the run of the junction chamber need to be changed in the CONDUIT LAYOUT. The minimum run for the junction chamber is 8 x nominal diameter of conduit. For example, the minimum run for a 2” dia. conduit is 1’-4” (8 x 2” = 16” = 1’-4”). If larger conduit is used, JUNCTION CHAMBER FRAME needs to be adjusted, i.e., spacing of screws needs to be adjusted. Also, the size of the concrete blister needs to be adjusted to provide additional space between the junction chamber and the light anchorage.
Longitudinal movement (for filling table):
Coefficient of linear expansion of:
concrete: 0.000006 in./in./F
steel: 0.0000065 in./in./F
STANDARD BCS-31A: NOTES TO DESIGNER
PART 3
DATE: 03May2018
SHEET 3 of 3
FILE NO. BCS-31A-3
BRIDGE CONDUIT SYSTEM FOR LIGHTING WITH CPSR SERIES RAILING
WITH SIDEWALK
NOTES TO DESIGNER (cont’d):
Temperature ranges:
concrete structures: 80F
steel structures: 120F
Example: Steel structure, 250 feet of expansion Longitudinal movement = 250 x 0.0000065 x 120 = 0.195 ft = 2¼ in.
t (movement/10F) = 250 x 0.0000065 x 10 = 0.01625 ft = 3/16 in.
ADD THE FOLLOWING NOTES, DIMENSIONS, DETAILS, ETC. TO STANDARD:
PLAN:
Add number and size of anchor bolts, and diameter of bolt circle. 4 - 1” anchor bolts may be used if design requirements in the previous page are met.
SECTION A-A: Add size of plate.
TABLE: Complete table. Use
1/8” multiples for longitudinal movement. Use
1/16” multiples for t
(movement/10F). REINFORCING STEEL SCHEDULE: Complete the No. (number of bars) column. For RT0601, input the length of bar. FL0401 bar dimensions and length are calculated for a 9” sidewalk depth at face of rail. Revise dimensions and lengths for other sidewalk depths at face of rail. NOTES: Complete first note by adding the Class I, II or III of corrosion resistant reinforcing steel required. For additional information on corrosion resistant reinforcing steel (CRR), see Structure and Bridge Division Memorandum (current IIM-S&B-81).