8/20/2019 Bc Conduit Catalog
2/34002BCCON0213
ISO 9001:2008 American Systems Registrar
Certificate No: 5107
INTERTEK ETL SEMKOConduit Systems: Medium Duty
Sizes: 20/25/32/50 mmTest Report Ref: 1301827-1
S INTERTEK Certification for
Medium, Heavy & Extra Heavy Duty ConduitsCertificate Ref: 1301827
S INTERTEK Certification for Junction Boxes
Certificate Ref: 1313485
INTERTEK ETL SEMKOConduit Systems: Heavy Duty
Sizes: 20/25/32/50 mmTest Report Ref: 1301827-2
INTERTEK ETL SEMKOConduit Systems: Extra Heavy Duty
Sizes: 20/25/32/50 mmTest Report Ref: 1301827-3
S INTERTEK Certification for
Fittings & Accessories for ConduitsCertificate Ref: 1313493
-
8/20/2019 Bc Conduit Catalog
3/34
BC CONDUIT
IEC, BRITISH & EUROPEAN SYSTEM
AMERICAN SYSTEM
-
8/20/2019 Bc Conduit Catalog
4/34
AREA Bahra Cables Company has a total land area of about 300,000sqm at disposal.
The built-up area, including offices and plant, of start up phase is more than 100,000sqm.
GENERALINTRODUCTION
BC Conduit has started production of a variety of high quality unplasticised polyvinyl chloride (UPVC)
compounds in its state-of-the-art factory in Bahra, which has an annual output capacity of over 36,000
tons.
The company sources UPVC feedstock for the new factory from Saudi Basic Industries Corporation
(SABIC) to produce the granule used for jacketing and insulating the cables. SABIC is one of the world’s
largest manufacturers of UPVC and the sole producer in Saudi Arabia.
The factory built with the expertise of Buss Company of Switzerland, is completely integrated and
equipped with the latest technologies in the field.
The ability to manufacture UPVC compounds improves BCC’s control over the material used in its cable
and wire production, reduces product cost and adds higher performance values to its products.
The new factory also eliminates the need for local sourcing of UPVC compounds, ensures superiorquality production of cables and creates more career opportunities in the region at the same time.
1
-
8/20/2019 Bc Conduit Catalog
5/34
BC CONDUITMATERIAL SPECIFICATIONS
MATERIAL INTRODUCTION
Unplasticised Poly(Vinyl Chloride), commonly known as UPVC, was first recognized and characterizedmore 110 years ago, but due to its poor thermal stability making processing difficult, it was potentially
introduced to the market only by 1930.
The problem caused by poor thermal stability were overcome by development of suitable stabilizers
systems and UPVC is now one of the world’s leading synthetic polymer having very diverse applications.
The ability to change its properties, by the addition of plasticisers, from a hard rigid material to one that
is soft and flexible enables a wide variety of processing equipment to be used to produce an almost
limitless range of products to a thick cream.
UPVC is used for the production of extrusions and molding. And it is universally accepted as having themost suitable properties for use within the electrical industry.
BC Conduit StandardsBC Conduit UPVC products are manufactured in accordance with the British Standards, American
Standard, SASO Standard, and UL Standards.
(*BS 6099: Part 1; Conduit for electrical installations. Specification of general requirements, is
superseded, withdrawn and replaced by BS EN 50086-1.
BS EN 50086-1; Conduit for electrical installations. Specification of general requirements superseded
and replaced by BS EN 61386-1).
BS EN 61386 (IEC 61386), Conduit Systems for cable management.
SASO (Saudi Standards, Metrology and Quality Organization) and GSO (Standardization Organization
for GCC). GSO 33; Plastic Conduits and Fittings for elctrical installations.BC Conduit UPVC materials used and tested in accordance with the British Standards (BS 4607: Part 1
and BS 476: Part 7).
IEE Wiring Regulations: Bahra System complies with all the relevant requirement of the latest edition
of the BS 7671 (IEE Wiring Regulations).
Product Certifications and ApprovalsBC Conduit is registered for ISO 9001, certified by American Systems Registrar (ASR).
BC Conduit is certified for European Product Safety for the following products:
• Medium, heavy and extra heavy duty grade type conduits Ref. 1301827• Fittings and accessories for conduits Ref. 1313493
• Junction Boxes Ref. 1313485
BC Conduit satisfies provisions for CE marking, according to Low Voltage Directive 2006/95/EC.
BC Conduit’s conduits & accessories are resistant to external influences according to following IP Codes:
• Extra Heavy duty conduits and accessories IP66
• Heavy and Medium duty conduits and accessories IP55
• Junction Boxes IP50
2
-
8/20/2019 Bc Conduit Catalog
6/34
BC CONDUITMATERIAL SPECIFICATIONS
BC CONDUIT MATERIAL PROPERTIES
Thermal Properties All BC Conduit UPVC products are planned to hold local thermal expansion. Fitting procedures andinstruction required to deal with the different movement at the interface with the building fabric.
Coefficient of linear expansion(Conduits) : 5.5 x 10-5 per C (5mm/3000mm with a temp. rise of 25oC).Coefficient of linear expansion (Trunking) :23 x 10-6 per C (1mm/m for 40oC rise).Operating Temperature : -5oC to 60oC (Minimum and Maximum Temperature)
Vicat Softening Point: 81oCThermal Conductivity : 0.19W/m/k
Chemical PropertiesBC Conduit UPVC(Chemical Resistance) is non corrosive (corrosive free) & not affected by sea water. It
has excellent resistance to mineral acids, alkalines and detergents, good resistant to alcohols , but liableto attack from solvents such as ketones, aromatics and hydrocarbons.* Corrosion only occur, to any extent when ph is less than 3 or greater than 9.
Mechanical PropertiesBC Conduit UPVC products (Impact Resistance under normal climatic conditions, BS EN 50086 or itsreplacement IEC 61386-21 (formerly BS 6099)).
Electrical PropertiesBC Conduit UPVC products are non conductive.Dielectric Strength : 40 kV/mm in DBP Resistivity : 1014 Ωcm 17 kV/mm in Tx oil Resistance to 0.03 ohm rnm²-/m
Workability, Durability & Maintenances All BC Conduit UPVC products are light weight and can be readily cut & drilled with hand tools. Shortcomponent length can be readily included, reducing wastage of material. The covers & accessories aremanufactured under fine tolerances to ensure a tight fit with ease of removal. Also can be cleaned with
wet cloth & household detergents (neutral 5/7 pH value), possible to decorate also with commercialpaint. Resistant to staining. Stop ends are tenable to the carriers. All BC Conduit products can maintainedtheir high performance characteristics and stable.
3
-
8/20/2019 Bc Conduit Catalog
7/34
BC CONDUITTECHNICAL
BC CONDUIT AND FITTINGS
Description:BC Conduit high impact UPVC conduit offers a cost effective solution for both new and renovationscontracts. The conduit available in sizes each with 4 different grades. The wide ranges of our fittings& supplementary products resources that almost any installation can be specified with confidence. Theconduits of BC Conduit easily cut using hacksaw or snips due to its light weight and also bent colddue to its smaller sizes. Thanks to these advantages, installation will be 50% quicker than using steel.Modification and repairs are quicker and simpler to be done.
Features:• Wide ranges of section and sizes.• 4 Grades of round conduit to suit various site situation.• Quicker, simpler and fast installation.
• Very wide ranges of component maximize versatile applications.• Round, oval and corrugated divisions are compatible.
Mechanism:Below is a list of available mechanism by name only:- Heavy Gauge Couplings- Bell Mouth Bushes/Sleeves- Expansion Couplings- Male/Female Bushes- Inspection Couplings- Plugs- Strap Saddles- Reducers
- Quickfit Spacer Saddles- Locknuts- Spacer Bar Saddles- Lockrings- Spring Clip Saddles- Adaptors- Conduit Clips- Bending Springs
- Quickfit Inspection Elbows- Normal Bends- Quickfit Inspection Tees- Compression Glands- Inspection Tees- Inspection Elbows
Boxes and AccessoriesBelow is a list of available boxes & accessories by name only.- Circular Boxes- Tee Boxes- Terminal Boxes
- Intersection Boxes- Through Boxes- Tangent Boxes
- Branch Boxes- Heat Resistant Boxes- Angle Boxes
4
-
8/20/2019 Bc Conduit Catalog
8/34
BC CONDUITTECHNICAL
BOXES AND ACCESSORIES
CONDUIT (ROUND SECTION HEAVY GAUGE HIGH IMPACT)
Accessories
- Extension Rings - BC Conduit Solvent Cement- Steel Insert Clip - BC Conduit Snip Cutter
- Earthing Ring - Nylon Draw Tape
- Brass Earthing Terminals
Conduit Boxes
- Adaptable Boxes - Bahra Earth Electrode Box
- Square Junction Boxes - Bahra Circular Lids and Gaskets
Switches and Socket Boxes
(The wide ranges are available in different depths with assorted of knockouts points). Observe the table
at the conclusion of this technical sector.
For classic conduit installation this provides a high degree of fortification or safety.
Temperature range: -5OC to 60OC (Minimum and Maximum), complies with BS 6099 section 2.2
Heavy Mechanical Stress (Section 2.2) complies with all related requirements of 16th edition of IEE
Wiring Regulation and provides high degree of fortification or safety.
Cable Capabilities of Conduit
The technique which can be used to establish the size of conduit or trunking required to hold cables
of the same size, or different sized. The number of cables arrange in an enclosure of a wiring system
shall be such that no damage is caused to the cables or to the enclosure during their installation. The
process employs a unit system, each cable size being allocated a part. The sum of all parts for the cables
intended to be run in the same enclosure is evaluate against the parts given for the conduit in order to
decide the size of the conduit required to hold those cables.
Note: Standard Length 2.9 meters
Outside W.Thickness Weight Cross Section
θ (mm) (mm) (kg/m) Area(mm²)
20 1.8 0.150 209
25 1.9 0.205 350
32 2.5 0.322 573
38 2.5 0.394 859
50 3.2 0.684 1506
5
-
8/20/2019 Bc Conduit Catalog
9/34
BC CONDUITTECHNICAL
Types of RunIt has been required for conduit to distinguish the run exceed 2.9m (the run not exceeding 2.9 metersin length) and runs of any length put in bend or sets as:
1. Straight Run not exceeding 2.9 meters in length.2. Straight Run exceeding 2.9 meters in length.
(The word “Bend” signifies a British Standard 90o Bend and one double set is equivalent to one bend)
Case 1. Each conduit size is represented by only one part.Case 2. Each conduit size has a inconsistent part which is dependent on the length of run and thenumber of bends or Expansion Couplings. For a certain size of cables the part allocated to case 1 is notthe same as case 2 above.
Variable Factors (Inconsistent Part) Different variable parts affect the effort to arrive at a standardmethod of evaluating the capability of conduit. Some of these are the following:- Tolerance in cables sizes - Reasonable Care (of drawing in)
- Tolerance in conduit - Acceptable use of the space available
15 YEARS GUARANTY
BC Conduit shall guaranty and warranty the supplied UPVC conduits and accessories for a period of 15years for indoor use only, from the date of delivery against the products malfunction due to material,
workmanship and manufacturing defects.
BC Conduit guaranty and warranty shall not apply if the customer uses or installs the products improperly, when such an improper use is judged using the national and /or internationally recognized standardsand codes of the electrical Industry.
The Guaranty shall not extend to items not manufactured by BC Conduit, or to any damages or defectsresulting from the use of products in a manner other than what these intentionally designed for, nor themishandling or misuse during their transport or storage.
Conduits, Grades, Area and WeightsBC conduits are manufactured and tested as per IEC / EN 61386 (previously BS 6099) to withstand a
wide range of impact and compression forces starting with Medium Duty (3321) for flush and serviceapplications, Heavy Duty (4421) for ceiling and wall installations, and Extra Heavy Duty (5521) forinstallation inside bulk concrete in temperature range of -5oC to 60oC.
The following table shows the Nominal Dimensions of each type:
* Extra Heavy Duty also available.
Medium Heavy Medium Heavy Extra Heavy
OutsideDiameter (mm)
Nominal Thickness (mm) Internal Area (mm2)
20 1.6 1.8 222 211 206
25 1.8 1.9 360 353 327
32 2.1 2.5 607 573 552
38 2.2 2.5 887 855 804
50 2.5 3.2 1590 1493 1439
6
-
8/20/2019 Bc Conduit Catalog
10/34
IEC, BRITISH & EUROPEAN SYSTEMTECHNICAL INFORMATION
IEC, BS & EN STANDARDS
-
8/20/2019 Bc Conduit Catalog
11/34
TECHNICAL INFORMATIONIEC, BS & EN STANDARDS
CABLE CAPACITIES OF CONDUITS(Based on Appendix 12 IEE Regulations 17th Edition to the latest edition)
1. For each cable it is intended to use obtain the appropriate cable factor.
2. Add all the cable factors so obtained and compare with the factors for conduit/trunking.
3. The size of trunking/conduit which will satisfactorily accommodate the cables is that size
having a factor equal to or exceeding the sum of the cable factors.
Single core UPVC insulated cables in straight runs of conduit not exceeding 3m in length
Single UPVC insulated cables in straight runs of conduit exceeding 3m in length or in runs of any length
incorporating bends or sets
Type of Conductor
Cable Factor Conduit Factor
Conductor Cross
Sectional Area(mm²) Factor Conduit
Diameter (mm) Factor
Solid
1 22 16 290
1.5 27 20 460
2.5 39 25 800
32 1400
Stranded
1.5 31
2.5 43
4 58
6 88
10 146
Type of Conductor Conductor Cross Sectional
Area (mm²)
Factor
Solidor
Stranded
1 16
1.5 22
2.5 30
4 43
6 58
10 105
4 58
8
-
8/20/2019 Bc Conduit Catalog
12/34
FIXING According to IEE regulations the following table shows the recommended distances between fixings.
Distance between fixings for conduit
TECHNICAL INFORMATIONIEC, BS & EN STANDARDS
ConduitSize in
mm
Maximum distance between fixings in meters
Metal Plastic Pliable
Horizontal Vertical Horizontal Vertical Horizontal Vertical
16 0.75 1 0.75 1 0.3 0.5
20 1.75 2 1.5 1.75 0.4 0.6
25 1.75 2 1.5 1.75 0.4 0.6
32&38 2 2.25 1.75 2 0.6 0.8
Over 40 2.25 2.5 2 2 0.8 1
9
-
8/20/2019 Bc Conduit Catalog
13/34
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
-
8/20/2019 Bc Conduit Catalog
14/34
HEAVY DUTY UPVC CONDUIT *
IEC CODE 4421 1250N
EXTRA HEAVY DUTY UPVC CONDUIT *IEC CODE 5521 4000N
ItemCode
NominalSize
(O.D.)
MinimumInside
Diameter
WallThickness
StandardPacks
BulkPacks
mm mm mm Pcs Mtrs Pcs
BSP 2 20 16.0 1.8 50 145 4550
BSP 3 25 20.7 1.9 40 116 2880
BSP 4 32 26.5 2.5 20 58 1800
BSP 5 38 32.5 2.5 20 58 1300
BSP 6 50 43.0 3.2 10 29 720
ItemCode
NominalSize (O.D.)
MinimumInside
Diameter
StandardPacks
BulkPacks
mm mm Pcs Mtrs Pcs
BEP 2 20 15.2 50 145 4550
BEP 3 25 19.7 40 116 2880
BEP 4 32 26.3 20 58 1800
BEP 5 38 32.0 20 58 1300
BEP 6 50 43.1 10 29 720
Available in 2 colors: Black and White. When ordering use color suffix BK WT
Available in 2 colors: Black and White. When ordering use color suffix BK WT
11
2006/95/ECLow Voltage Directive
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
* Manufactured According to BS 6099, EN 61386 (IEC 61386), Standard length 2.9m. Other lengths available on request
Ref: 1301827
-
8/20/2019 Bc Conduit Catalog
15/34
MEDIUM DUTY UPVC CONDUIT *IEC CODE 3321 750N
LIGHT DUTY UPVC CONDUIT *IEC CODE 2221 320N
ItemCode
NominalSize
(O.D.)
MinimumInside
Diameter
WallThickness
StandardPacks
BulkPacks
mm mm mm Pcs Mtrs Pcs
BMP 2 20 16.5 1.6 50 145 4550
BMP 3 25 20.9 1.8 40 116 2880
BMP 4 32 27.3 2.1 20 58 1800
BMP 5 38 33.1 2.2 20 58 1300
BMP 6 50 44.4 2.5 10 29 720
ItemCode
NominalSize
(O.D.)
MinimumInside
Diameter
WallThickness
StandardPacks
BulkPacks
mm mm mm Pcs Mtrs Pcs
BLP 2 20 17.2 1.2 50 145 4550
BLP 3 25 21.7 1.4 40 116 2880
BLP 4 32 28.5 1.5 20 58 1800
BLP 5 38 34.5 1.5 20 58 1300
BLP 6 50 45.6 1.9 10 29 720
* Manufactured According to BS 6099, EN 61386 (IEC 61386), Standard length 2.9m. Other lengths available on request
Available in 2 colors: Black and White. When ordering use color suffix BK WT
Available in 2 colors: Black and White. When ordering use color suffix BK WT
12
2006/95/ECLow Voltage Directive
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
Ref: 1301827
-
8/20/2019 Bc Conduit Catalog
16/34
STANDARD COUPLING
EXPANSION COUPLING
BENDS-HEAVY GAUGE WITH BELL ENDS
BENDS-HEAVY GAUGE WITH COUPLINGS
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BSC 2 20 100 20,000
BSC 3 25 100 10,000
BSC 4 32 25 5,000
BSC 5 38 25 2,500
BSC 6 50 20 2,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BEC 2 20 50 800
BEC 3 25 25 625
BEC 4 32 20 260
BEC 5 38 10 250
BEC 6 50 10 120
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BLB 2 20 30 3,000
BLB 3 25 15 1,500
BLB 4 32 100 600
BLB 5 38 60 360
BLB 6 50 25 150
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BNB 2 20 30 3,000
BNB 3 25 15 1,500
BNB 4 32 100 600
BNB 5 38 60 360
BNB 6 50 25 150
2006/95/ECLow Voltage Directive
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
Ref: 1313493
13
-
8/20/2019 Bc Conduit Catalog
17/34
ROUND SPRING CLIPS
FEMALE ADAPTORS
MALE ADAPTORS
MALE THREADED BUSH
FEMALE THREADED LOCKRINGS
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BCC 2 20 200 5200
BCC 3 25 100 4000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BFA 2 20 100 20,000
BFA 3 25 100 10,000BFA 4 32 25 5,000
BFA 5 38 25 5,000
BFA 6 50 20 3,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BMA 2 20 100 20,000
BMA 3 25 100 20,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
TBM 2 20 100 20,000
TBM 3 25 100 20,000
TBM 4 32 100 2600
TBM 5 38 50 2000
TBM 6 50 25 1000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
TLF 2 20 100 20,000
TLF 3 25 100 20,000
2006/95/ECLow Voltage Directive
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
Ref: 1313493
14
-
8/20/2019 Bc Conduit Catalog
18/34
INSPECTION ELBOWS
INSPECTION BENDS
INSPECTION TEES
STRAP SADDLES
SADDLE WITH BASE
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BIE 2 20 25 650
BIE 3 25 25 400
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BIB 2 20 25 400
BIB 3 25 20 320
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BIT 2 20 20 520
BIT 3 25 20 320
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BPS 2 20 200 40,000
BPS 3 25 200 40,000
BPS 4 32 100 20,000
BPS 5 38 25 2000
BPS 6 50 25 1300
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BSB 2 20 100 20,000
BSB 3 25 100 20,000
BSB 4 32 100 10,000
BSB 5 38 25 1000
BSB 6 50 25 650
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
15
-
8/20/2019 Bc Conduit Catalog
19/34
-
8/20/2019 Bc Conduit Catalog
20/34
ANGLE – TWO WAY BOX
TEE – THREE WAY BOX
INTERSECTION – FOUR WAY BOX
U – TWO WAY BOX
Y – THREE WAY BOX
H – FOUR WAY BOX
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/4 20 25 2,500
3/BRB/4 25 25 2,500
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/5 20 20 2,000
3/BRB/5 25 20 2,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/6 20 20 2,000
3/BRB/6 25 20 2,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/12 20 25 2,500
3/BRB/12 25 25 2,500
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/13 20 25 2,500
3/BRB/13 25 25 2,500
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/14 20 25 2,500
3/BRB/14 25 25 2,500
2006/95/ECLow Voltage Directive
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
Ref: 1313485
17
-
8/20/2019 Bc Conduit Catalog
21/34
CIRCULAR LIDS
RUBBER GASKET
CIRCULAR JUNCTION BOXES FITTED WITH RUBBER GASKET, LID & SCREWSCircular Junction Boxes Fitted With Rubber Gasket, Lid & Screws - Circular Boxes can be suppliedassembled with rubber gasket, lid & screws. E.g. Item codes for 20mm 2 way through circular junctionbox DJT 2 should be suffixed with/RG as DJT 2/RG
Heavy Gauge springs are suitable for heavy & medium gaugeround conduits while light gauge springs are suitable for lightgauge round conduits
BENDING SPRINGS
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BSL 2 15 200 40,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
BRG 66 100 2600
HeavyGauge
Item Code
ConduitSize (mm)
Light GaugeItem Code
Bulk Packs
BSS H2 20 BSS L2 -
BSS H3 25 BSS L3 -
UPVC CEMENT
Item Code Size (ml) Standard Packs Bulk Packs (Pcs)
BSG 1 118 48 -
BSG 2 237 24 1008
BSG 3 473 12 600
BSG 4 946 6 -
Available in 118ml, 237ml, 473ml and 946ml cans with applicator.Suitable for use with BC UPVC conduit, trunking & fittings.
Available in 2 colors: Black and White. When ordering use color suffix BK WT
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
18
-
8/20/2019 Bc Conduit Catalog
22/34
TERMINAL ONE WAY & BACK OUTLET
THROUGH TWO WAY & BACK OUTLET
ANGLE TWO WAY & BACK OUTLET
TEE THREE WAY & BACK OUTLET
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/7 20 20 3,000
3/BRB/7 25 20 3,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/8 20 20 3,000
3/BRB/8 25 20 3,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/9 20 20 3,000
3/BRB/9 25 20 3,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/10 20 20 3,000
3/BRB/10 25 10 1,500
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
2006/95/ECLow Voltage Directive
Ref: 1313485
19
-
8/20/2019 Bc Conduit Catalog
23/34
INTERSECTION FOUR WAY & BACK OUTLET
U- TWO WAY & BACK OUTLET
Y-THREE WAY & BACK OUTLET
H FOUR WAY & BACK OUTLET
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/11 20 10 1,500
3/BRB/11 25 10 1,500
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/15 20 20 3,000
3/BRB/15 25 20 3,000
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/16 20 20 3,000
3/BRB/16 25 10 1,500
Item Code Size (mm) Standard Packs Bulk Packs (Pcs)
2/BRB/17 20 10 1,500
3/BRB/17 25 10 1,500
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
All above products available in 2 colors: Black and White. When ordering use color suffix BK WT
2006/95/ECLow Voltage Directive
Ref: 1313485
20
-
8/20/2019 Bc Conduit Catalog
24/34
ADAPTABLE BOX
WIRE PULLER
Item Code Size (mm) Standard Packs
BAB 1 100x100x60 150
BAB 2 130x130x74 28
BAB 3 215x215x110 10
Item Code Diameter (mm) Size (meter)
BWP 1 4.5 15
BWP 2 4.5 30
Available in Grey color only
Available in White color only
IEC, BRITISH & EUROPEAN SYSTEMIEC, BS & EN CONDUIT SYSTEM
21
-
8/20/2019 Bc Conduit Catalog
25/34
AMERICAN SYSTEMTECHNICAL INFORMATION
AMERICAN STANDARDS
-
8/20/2019 Bc Conduit Catalog
26/34
TECHNICAL INFORMATION AMERICAN STANDARDS
BC American Standard Conduits:
UPVC Material
Manufacturing Standards
Heavy wall and extra-heavy wall rigid plastic (UPVC) conduit, fittings and accessories designed for
installation underground, in slab, encased or light weight, high-impact strength and low installationcosts. Supplied in standard 10’ lengths, with or without belled ends.
Encased in concrete or direct burial for underground applications, also for exposed or concealed
applications aboveground. Sunlight resistant, rated for use with 90°C conductors, reduced smoke and
HCL emissions, superior weathering characteristics.
Specifications: UL type 40 rated for 90°C cable can be used in above ground or below ground applications
subject to severe physical abuse.
Rigid UPVC Compound which fully meets the material requirements of American specifications for cellas per ASTM D 1784 and ASTM D 4396 as specified in NEMA Standards.
NEMA TC 2 Electrical Plastic Tubing (EPT) and Conduit (EPC-40 and EPC-80)
NEMA TC 6 UPVC Plastic Utilities Duct for underground installation
&
NEMA TC 8 Extra-Strength UPVC Plastic Utilities Duct for underground installation
ASTM F 512 Smooth-wall UPVC Conduit and fittings for underground installation
23
-
8/20/2019 Bc Conduit Catalog
27/34
TECHNICAL INFORMATION AMERICAN STANDARDS
UPVC PROPERTIES
PROPERTY ASTM TEST METHOD UNIT VALUE
General Properties:
Density D-792 g/cm³ 1.44 0.02
Water Absorption D-570/Proc. A % 0.3
Mechanical Properties:
Tensile Strength, Ultimate D-638/Type 1 kg/cm² 421.1
Modulus of Elasticity D-638/Type 1 Mpa 1930
Flexural Strength D-695, D-790/Proc. B Mpa 77
Hardness D-785 Shore D 119
Izod Impact Strength D-256/method A J/M 34.7Thermal Properties:
Heat Deflection Temp. D-648 (1.82 Mpa load) °C/ (°F) > 70(158)
Vicat Softening Temp. D-1525 (rate A) °C/ (°F) > 70(158)
Co-efficient of ThermalExpansion
D-696/3m length mm/m/10°C 1.6
Thermal Conductivity C-177 W/(°Km) 0.14
Flammability Properties:
Flammability D-635 Resistance Self extinguishing
Extent of Burning D-635 mm
-
8/20/2019 Bc Conduit Catalog
28/34
AMERICAN SYSTEMAMERICAN CONDUIT SYSTEM
-
8/20/2019 Bc Conduit Catalog
29/34
AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM
RIGID UPVC CONDUITSNEMA TC 2 “Electrical Polyvinyl Chloride (UPVC) Conduit” Schedule 40
Item CodeTradeSize
(inch)
MetricDesignators
Averageoutside
diameter mm
SCH-40
StandardPacks
BulkPacks(Pcs)
WallThickness(Min.) mm
Nominal Weight
Kg/m
BAC/105 ½ 16 21.34 2.77 0.248 40 3,640
BAC/107 ¾ 21 26.67 2.87 0.329 30 2,160
BAC/110 1 27 33.40 3.38 0.483 20 1,440
BAC/112 1¼ 35 42.16 3.56 0.652 20 900
BAC/115 1½ 41 48.26 3.68 0.779 10 720
BAC/120 2 53 60.32 3.91 1.04 10 450
BAC/130 3 78 88.9 5.49 2.16 - -
BAC/140 4 103 114.3 6.02 3.07 - -
BAC/160 6 155 168.28 7.11 5.41 - -
26
-
8/20/2019 Bc Conduit Catalog
30/34
27
AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM
RIGID UPVC CONDUITSBS 3506-1969 Class-B 6.0 bar
Item CodeTradeSize
(inch)
Mean Outside Diameter
Average Value
Max
Individual Value
Min Max Minmm
Max mm
BIP/130 3 88.7 89.1 3.4 2.9 3.4
BIP/140 4 114.1 114.5 4 3.4 4
BIP/150 5 140.0 140.4 4.4 3.8 4.4
BIP/160 6 168.0 168.5 5.2 4.5 5.2
COUPLING
Item Code Size (inch) Standard Packs Bulk Packs (Pcs)
BSC/105 1/2 100 20,000
BSC/107 3/4 100 10,000
BSC/110 1 50 5,000
BSC/112 11/4 25 2,500
BSC/115 11/2 25 2,500
BSC/120 2 20 2,000
-
8/20/2019 Bc Conduit Catalog
31/34
AMERICAN SYSTEM AMERICAN CONDUIT SYSTEM
90O ELBOW - PLAIN END
90O ELBOW - BELL ONE END
90O ELBOW - BELL TWO ENDS
Schedule 40
Schedule 40
Schedule 40
28
Item Code Size (in) Standard Packs Bulk Packs (Pcs)
BEPC2 1/2 20 2,000
BEPC3 3/4 10 1,000
BEPC4 1 100 600
BEPC5 11/4 50 300
BEPC6 11/2 50 300
BEPC7 2” 25 150
Item Code Size (in) Standard Packs Bulk Packs (Pcs)
BEPC2/1S 1/2 20 2,000
BEPC3/1S 3/4 10 1,000
BEPC4/1S 1 100 600
BEPC5/1S 11/4 50 300
BEPC6/1S 11/2 50 300
BEPC7/1S 2” 25 150
Item Code Size (in) Standard Packs Bulk Packs (Pcs)
BEPC2/2S 1/2 20 2,000
BEPC3/2S 3/4 10 1,000
BEPC4/2S 1 100 600
BEPC5/2S 11/4 50 300
BEPC6/2S 11/2 50 300
BEPC7/2S 2” 25 150
-
8/20/2019 Bc Conduit Catalog
32/34
15 YEAR GUARANTY
BC Conduit shall guaranty and warranty the supplied UPVC conduitsand accessories for a period of 15 years for indoor use only, from thedate of delivery against the products malfunction due to material,
workmanship and manufacturing defects. BC Conduit guaranty and warranty shall not apply if the customeruses or installs the products improperly, when such an improperuse is judged using the national and /or internationally recognizedstandards and codes of the electrical Industry.
The Guaranty shall not extend to items not manufactured by BCConduit, or to any damages or defects resulting from the use ofproducts in a manner other than what these intentionally designedfor, nor the mishandling or misuse during their transport or storage.
5107
29
-
8/20/2019 Bc Conduit Catalog
33/34
AluminumFactory
Pre CastFactory
for Concrete
TrainingInstitute
for Technology
Roundabout
M A K K A H
R O A D
T o M
a k k
a h
To Makkah
T o
J e d d
a h
B a h r a F l y o v e r
PREMCO
N
INDUSTRIAL PARK
K ing A bdul A z iz Medic al Cit y
-
8/20/2019 Bc Conduit Catalog
34/34