BC-2028User Guide
Replication without approval from Our Company is forbidden.
Any operation for all products depends on actual operating status.Due to continuous product updates, we don't promise the actualproduct is the same as one presented in the document, neither bearwe any dispute arising from any inconsistence between actualoperation and those procedures described in the document.
-
7/27/2019 BC-2028 Manual
2/50
Contents
INTRODUCTION...................................................................................II1NECESSARY TO KNOW ..............................................................VII2BASIC CONCEPTS.............................................................................8
2.1.BASIC CONCEPTS...............................................................................8
2.1.1.User Enrollment........................................................................8
2.1.2.User Verification.......................................................................8
2.1.3.Match Threshold Levels............................................................8
2.1.4.User ID Numbers......................................................................92.1.5.Authority (status) Levels...........................................................9
2.1.6.Start-up window......................................................................10
2.2.HOWTOPLACETHEFINGER............................................................10
3ENROLLMENT AND VERIFICATION PROCEDURES.............113.1.ENROLLING USERS..........................................................................12
3.1.1.Fingerprint Enrollment...........................................................13
3.1.2.Password Enrollment..............................................................14
3.1.3.Fingerprint & Password.........................................................153.2.TESTINGAN ENROLLMENT..............................................................18
3.3.ENROLLINGA USERWITHTHE DISPLAY FINGEROPTION ON.........18
3.4.VERIFYING YOURIDENTITY............................................................18
3.4.1.Fingerprint Verification..........................................................18
3.4.2.Password Verification.............................................................19
3.4.3.Password & Fingerprint.........................................................19
3.4.4.EM card enrollment ..............................................................20
3.4.5.EM card & Fingerprint...........................................................203.5.HINTSFORSUCCESSFUL ENROLLMENTS.........................................20
4SYSTEM SETUP................................................................................234.1.SYSTEM SETUP................................................................................24
4.1.1.Date Time................................................................................24
4.1.2.Language.................................................................................24
4.1.3.Format.....................................................................................25
4.1.4.Advanced Options...................................................................25
4.2.COMMUNICATION OPTIONS.............................................................274.3.LOG SETUP......................................................................................28
I
-
7/27/2019 BC-2028 Manual
3/50
User Guide
4.4.LOCKSET........................................................................................29
5SYSTEM INFORMATION...............................................................316TROUBLE SHOOTING....................................................................327USER ACC OPTS GUIDE................................................................33
7.1.PRODUCT FEATURES........................................................................33
7.2.BASIC CONCEPTS.............................................................................33
7.3.ACCESS OPTIONS.............................................................................34
7.3.1.Brief Introduction to Access Options .....................................35
7.3.2.Verification Flow of Access Options ......................................36
7.4.FUNCTION DESCRIPTION.................................................................387.4.1.Definition of Time zone...........................................................38
7.4.2.Definition of Grouping Function.............................................40
7.4.3.User Acc Opts .........................................................................42
7.4.4.Access Comb...........................................................................45
TECHNICALSPECIFICATIONS..................................................................49
IntroductionIn this chapter, details of the common terms and the finger
print press manner are presented.BC-2028 Fingerprint Access Control System
II
-
7/27/2019 BC-2028 Manual
4/50
OK Confirm key: confirm your current present operation;M Enter the management interface in the initial status;C Cancel your present operation
Scrolling up key: Scrolling up the menu Scrolling up key: Scrolling down the menu
Door bell;
Control the power on and off. Or digital 0
Number keys: Input number 0-9
BC-2028 is a simplified-designed terminal unit fingerprintAccess controller, and use easy,. It can be assembled on thesensitive area need authority to access; Be comminuted with thehigh-safe fingerprint identification system and advance AccessControl management creatively, so that come true high-safemanagement of in-out control.
Port description
III
-
7/27/2019 BC-2028 Manual
5/50
User Guide
J9lead foot Color function declaration
RS485- blue RS485communication -
IV
-
7/27/2019 BC-2028 Manual
6/50
RS485+ orange RS485communication +
GND black RS485communication GND
RS232T yellow RS232 TXD(NC)
RS232R purple RS232 RXD(NC)
GND black RS232communication GND
DS-IN brown Door Contact+
OPEN gray Open key+
J10lead foot Color function declarationCOM orange electric relaycommon terminalNC purple electric relayNC
NO blue electric relayNOVG-OUT1 green VG out export D0
VG-OUT2 white VG out export D1
GND black VG communication GND
BELL1 red BELL 1
BELL2 brown BELL 2
ALARM1 yellow Warning 1
ALARM2 gray warning2
V
-
7/27/2019 BC-2028 Manual
7/50
User Guide
VI
-
7/27/2019 BC-2028 Manual
8/50
.Installation drawing
1
Necessary to knowPlease do not place the product in the place with strong light,because the strong light may significantly affect the finger printscanning, and thus cause the print verification fail.
Try to avoid using outdoor, the working temperature range ofthe attendance machine is 0-400C. Usage outdoor of long period, inaddition to the internal heat of the machine, will cause problem tothe operation, including the decrease of the reaction and thepassing rate. If outdoor usage can not be avoided, it is suggested touse sun umbrella and cooling facility.
VII
-
7/27/2019 BC-2028 Manual
9/50
User Guide
2 Basic Concepts2.1. Basic Concepts
This section contains definitions and descriptions ofFingerprint T&A Concepts including: User Enrollment
.User Verification
Match Threshold Levels
User ID Numbers
Authority (Status) Levels
The two most important Fingerprint T&A Functions areuser enrollment and user verification.
2.1.1. User EnrollmentEnrollment is the process of create an ID number and
scanning a users finger to create a template three times. Thistemplate is associated with a user ID number and stored.
During user verification, the stored template is compared tothe current fingerprint scan to confirm the users identity.
Enrollment is performed at designated units. The user can
verify on the time recorder that enroll his fingerprint. Theenrollment process takes approximately 1 second.
Up to 3 fingers can be enrolled for the same ID number, sothe user may have more verifications way.
Ideally, it is better to enroll more than one finger for backup sothat if the user injures the enrolled finger have an alternate fingertemplate is available. While recording the finger type is optional, it isrecommended such as left or right index, so that at verification the
user is prompted as to which finger to use.
2.1.2. User VerificationVerification ways: You can use F/P/C, P, C, F+P, F+CF
Finger, P: Password C: EM card . You can use this waysverification your enrollment message is successful or fail.
2.1.3. Match Threshold Levels
The Mach Threshold is a number that represents thedegree to which verification is examined to ensure that the
8
-
7/27/2019 BC-2028 Manual
10/50
person is the person claimed.The Match Threshold Levels establishes a balance
between False Acceptance Rate (FAR) and False RejectionRate (FRR). FAR measures how often a non-authorized user isfalsely recognized and granted access to the system. FRRmeasures how often an enrolled and authorized user, whoshould be granted access to the system, is denied on the basisthat the system did not recognize him.
You can set match threshold levels on a per-use basis. Forthe fingerprint verification is difficult, you can adopt ID &Fingerprint verification (match one to one).
Raising the threshold increases security, while lowering itincreases throughout. The correct balance is essential.
For users with worn or damaged fingers, match thresholdlevels can (and should) be reduced.
Different sites have different requirements.
Table 11 Suggested Match Threshold Settings
FRR FAR
Match Threshold Settings
1N 11High Low 4 40-50
Middle Middle 3 20-40Low High 1-2 0-20
2.1.4. User ID NumbersBefore beginning fingerprint enrollment, a user is assigned
User ID Number. This ID number is used to call up thefingerprint template each time that verification is requested.
ID numbers are normally called up via the keypad, but theycan be called up through other means such as RF Card.
2.1.5. Authority (status) LevelsFingerprint T&A has four authority or status levels:
Users are people whose identity must be verified,such to gain access to a facility or to have theirattendance recorded.
Enrollers are Users who are authorized to enroll new
9
-
7/27/2019 BC-2028 Manual
11/50
User Guide
users or delete on to the system.
Managers can do other operations, except set
advanced option and enroll managers authority. Supervisors are Users who access to all functionsand change all setup in the system.
Note: Without Manager and Supervisor status in the system, theEnroller will enroll them. And if there isnt a Supervisor in the system, theManager will enroll him.
2.1.6. Start-up windowWhen the machine is connected to the power source and
before the Power on button is pressed, the screen will display aso-called initial interface, as following:
2.2. How to place the finger
The correct way is:
Place a finger flatware on the sensor surface
Place it to the center of the sensor surface
The wrong way is:
10
Welcome 09:08:20
08-04-30 WED
-
7/27/2019 BC-2028 Manual
12/50
Note:Please adopt the correct way to place the finger;Our Company isnot responsible for the malfunctioning results arising from improper pressingmanners. Our company reserve ultimate the interpreting and modifying right
for this.
3 Enrollment and Verification ProceduresThis chapter describes how to enroll and verify users on
the Fingerprint T&A verification system.The following topics are included:
Enrolling User
Testing an Enrollment Enrolling a User with the Display Finger Option On
Verifying Your Identity
Hints for Successful Enrollments
Note: You must have Enroller, Manager, or Supervisorstatus to enroll users. For information on status levels, seeAuthority (Status) Levels on 1.1.5.
11
-
7/27/2019 BC-2028 Manual
13/50
User Guide
3.1. Enrolling UsersIf this is the first enrollment in a new or empty system,
everyone will become an enroller.If there is a manager in the system, you will have Manager
Status to enroll a new user.There are five ways of enrollment, fingerprint enrollment;
password enrollment, fingerprint & password, EM card,fingerprint & EM card. Fingerprint enrollment suited the mostpeople who have better quality fingerprints; Fingerprint &Password, EM card, fingerprint & EM card suite people whohavent the good fingerprint.
To start the enrollment process, identify yourself firstlypress [Menu], enter your ID number or fingerprint, and then verifyyour identity.
Note: If this is the first enrollment in a new or empty system, youwill not be prompted for verification.
The following message appears on the display:
Press Up or Down key, select what you need options:
Select Enrollment, Press OKthe following message display:
12
Menu
Enrollment
Menu
Setup
Menu
System Info
Enrollment
Manager
-
7/27/2019 BC-2028 Manual
14/50
Press Up or Down key select what you need options:
Select user, Press [OK], the following message display:
Press Up or Down key select what you need options:
3.1.1. Fingerprint Enrollment(1) Access the Finger Data to press [OK], the following display:
(2) Press [OK], the following appears:
13
Enrollment
UserEnrollment
Delete
User
Finger Data
User
Password
User
Fp + Pass
User
Card
User
Fp + Card
New Enroll
No-ESC Yes-OK
New Enroll
ID 0000008
-
7/27/2019 BC-2028 Manual
15/50
User Guide
(3) Input the enrolling number (the range is 1 to 9999999),press [OK], the following appears:
(4) If the test is successful three times in a row, the followingappears:
Note: 0000008-0The last number 0 meansthe first fingerprint.
Press [OK], the previous message continues to be displayedwhile the template is created.
If your identity cannot be verified, you are prompted to tryagain. And you must restart the verification procedure (step 3).
3.1.2. Password Enrollment(1) Access the password enrollment, press [OK], the following
appears:
(2) Press [OK], the following appears:
(3) Input the enroll number (the range is 1 to 999999999),press [OK], the following appears:
14
Press Finger #1
0000008-0
Enroll OK
New Enroll
No-ESC Yes-OK
New Enroll
ID 0000002
New Enroll
PWDIn *******
-
7/27/2019 BC-2028 Manual
16/50
Note: The password range is 1 to 7.
(4) Input the password, press [OK], the following appears:
(5) Input the password again, presses [OK], the followingappears:
The previous message continues to be displayed whilethe template is created.
3.1.3. Fingerprint & PasswordAccess the Fp+& Pass, press [OK], the following appears:
(2) Press [OK], the following appears:
(3) Input the id (range is 1 to 9999999), press [OK], thefollowing appears:
(4) If the test is successful three times in a row, thefollowing appears:
15
Note: 0000002-P
The last letter P means password.
New Enroll
Confm *******
0000002-P
Enroll OK
New Enroll
No-ESC Yes-OK
New Enroll
ID 0000003
Press Finger #1
-
7/27/2019 BC-2028 Manual
17/50
User Guide
(5) Input your password, the following appears:
(6) Input the passwords again, press [OK], the followingappears:
The previous message continues to be displayed while the
template is created.
4.1.4 EM card
(1) Access the EM card enrollment, press [OK], the followingappears:
(2) Press [OK], the following appears:
(3) Input the enroll number (the range is 1 to 999999999),press [OK], the following appears:
Note: The password range is 1 to 7.
16
PWDIn *******
New Enroll
Confm *******
0000003-P
Enroll OK
New Enroll
No-ESC Yes-OK
New Enroll
ID 0000002
New Enroll
PWDIn *******
-
7/27/2019 BC-2028 Manual
18/50
(4) Then you can input the card, press [OK], the followingappears:
When you complete it, press [OK]. The previous messagecontinues to be displayed while the template is created.
4.1.4 EM card & Fingerprint(1) Access the EM card & Fingerprint enrollment, press [OK],
the following appears:
(2) Press [OK], the following appears:
(3) Input the enroll number (the range is 1 to 999999999),press [OK], the following appears:
Note: The password range is 1 to 7.(4) When you enroll your finger you can input the EM card,
press [OK], the following appears:
The previous message continues to be displayed while the
template is created.
17
Card Inxxxxxxxxxx
New Enroll
No-ESC Yes-OK
New Enroll
ID 0000002
Card In
xxxxxxxxxx
Press Finger #1
-
7/27/2019 BC-2028 Manual
19/50
User Guide
3.2. Testing an Enrollment
Ask the users to place their finger to perform testverification. If the test was successful, you will adopt Fingerprintenrollment. If the poor quality of fingerprint, you will berecommended to use Fingerprint & Password.
3.3. Enrolling a User with the Display Finger Option OnPress [ESC] to the Display Dinger Option On, the following
appears:
Note: Where system memory permits, it is advisable tohave at least two fingers enrolled for a long-term user.
3.4. Verifying Your IdentityThe workers used Fingerprint T&A to verify their identity.
The system defaults to three ways of verification: Fingerprint
verification, Password verification, ID number & Fingerprint. Thefollowing appears:
3.4.1. Fingerprint VerificationPlace the finger on the sensor surface, the following
appears:
It continues for about 0.5 seconds.
If the test is successful, it will say Thank you, thefollowing appears:
If your identity cannot be verified, you are prompted to try
18
New Enroll
No-ESC Yes-OK
Backup
ID 0000003
Fp Verify
Take off !
ID 0000008
Verify OK !
-
7/27/2019 BC-2028 Manual
20/50
again, the following appears:
It continues for about 0.5 seconds, return to the start-upwindow.
3.4.2. Password VerificationTo start the enrollment process, enter your ID number, the
following appears:
Press [OK], the following appears:
Input correct password, press [OK], the following appears:
If the password cannot be verified, the following appears:
3.4.3. Password & FingerprintTo start the enrollment process, enter your ID number, the
following appears:
19
Fp VerifyAgain Inputf !
ID 3Esc-ESC Pwd-
Pass Verify
PWDIn *******
ID 0000003
Verify OK !
Pass Verify
Again Inputf !
ID 8Esc-ESC Pwd-
-
7/27/2019 BC-2028 Manual
21/50
User Guide
Press your finger,
If your identity is verified, the following appears:
3.4.4. EM card enrollmentTo start the enrollment process, touch your EM card, if your ID is
verified, the following appears:
3.4.5. EM card & FingerprintTo start the enrollment process, touch your EM card or enter your
finger, if your identity is verified, the following appears:
3.5. Hints for Successful Enrollments
The fingerprint is of good quality, the verification speed willfast; otherwise, it will verify slowly or occur to FRR.
20
1:1 Fp Verify
Take off
ID 0000008
Verify OK
ID xxxxxx
Verify Ok
Fp Verify
Take off !
ID xxxxxx
Verify Ok
-
7/27/2019 BC-2028 Manual
22/50
In order to improve the fingerprint verification quality, thefollowing hint appears:
Figure Error: Reference source not found-1Enrolled unsuccessfulor the fingerprint of poor quality:
Dry or dirtyfingerprints
Solve the dry problems that rub thedry finger and palm.
If the fingerprint is dry, you will adoptthe way of wetting up the finger, suchas ah-ah.
Have no enough to
bring pressure
The user should place a finger firmly
and squarely on the sensor surface.
How to select thefinger?
Recommend to left or right index ormiddle finger.
Use fingerprints of good quality,without worn or hurt.
The user usually selects theforefinger, if it was of a poor quality, youwill be recommended to middle finger
or ring finger.If the users finger is less, you will
select the thumb.
How to place thefinger?
Place your finger firmly and touch thesensor surface must be over 2/3.
The fingerprint does not touch uprighton the sensor surface.
Do not touch the finger too fast; Do
not move the finger on the sensorsurface.
The influence of thefingerprints change
For users with worn or damagedfingers, the identification can beinfluenced.
If the finger quality was poor, you willselect password verification.
21
-
7/27/2019 BC-2028 Manual
23/50
User Guide
Others
However, few peoples fingerprintquality is too poor to verify thefingerprint in gear. Please use ID &fingerprint verification, and the MatchThreshold Levels can be reduced oruse password verification.
22
-
7/27/2019 BC-2028 Manual
24/50
4 System Setup
Press MENU key in the initial interface, and the systemmay identify the proper right of the user, and then the screenshall display the following information:
Press Up or Down key, select Setup
Choose the setup, enter the next step, then the followinginformation will be displayed:
In the setup options, there are six choices: system setup,communication setup, log setup, door lock function setup. Nowwe introduce these one by one.
MenuSetup
Menu
Enrollment
Setup
Log Setup
Setup
System
Setup
Communication
Setup
Lock set
23
-
7/27/2019 BC-2028 Manual
25/50
User Guide
4.1. System SetupAccess System , the following appears:
The setup facility covers four areas: Date Time, Language,
and Advanced Options.
4.1.1. Date TimeAccess Date Time, the following appears:
To change the date press Up and Down Key , or input thecorrect date and time valuer, press [OK] to change your selecte,press [ESC] the following appears
4.1.2. Language
Select the wanted language and press OK. The defaultlanguage is simplified Chinese, the screen shall display
System
Time
System
Language ENGLISH
SystemDateFormat Y-M-D
System
SuperSet
2008-04-29
94756 WED
Save?
NO-ESC Yes-OK
24
-
7/27/2019 BC-2028 Manual
26/50
Chinese.
Press the up and down key to choose the language. Theattendance supports three languages: simplified Chinese, traditionalChinese, and English. On the screen, these may be displayed assimplified, traditional, and ENG respectively.
Choose the wanted language, and press OK. Then press ESCto exit the system setup. The system may indicate you to save the
change. You may press OK to confirm and change the systemlanguage setup.
Traditional Chinese Simplified Chinese
4.1.3. FormatPress UP or Down, select Fmt, Press OK, and modify Fmt,
There are four formats Y-M-
DY/M/DY.M.DD.M.YD/M/YD-M-Y M.D.YM/D/YM-D-Y. It will modify date format on original interface
For example: Y/M/D is left figureY-M-D is right figure:
4.1.4. Advanced Options
Access SuperSet Option, press [OK], the followingappears:
System
Language ENGLISH
System
DateFormat Y-M-D
Welcome 173708/04/30 WED
Welcome 173708-02-18 WED
25
-
7/27/2019 BC-2028 Manual
27/50
User Guide
Press UP or Down key select option, all display as follows
Press Up and Down Key to scroll up or down the screen toselect the option.
Default:: restore all setup information to defaultAll Log Delete: delete all logs of flash disk.
System
Default
System
All Log Delete
System
All Datele
System
Cancel Manager
System
1:N Level 3
System
Init 1:1 40
System
VoiceOut No
System
Managers 5
26
-
7/27/2019 BC-2028 Manual
28/50
All Delete: delete all enrolling fingerprints and logs.Cancel Manager: change the managers rights into ordinary
users rights.1:N Levels: For helping in selecting threshold level settings,
see Table 3.1.3.1 to 1Whetherinput the staff ID No.;1:1 Threshold Levels: ID+ Fingerprint identification and
degree of register template matching, Please see Table 3.1.3VoiceOut: Whether use to phonic hint or not.Managers Max managers rights into ordinary users count.
4.2. Communication OptionsEnter the communication menu; the screen shall display
the following information:
CommunicationBaudrate 38400
Communication
Device ID 1
Communication
Parity None
Communication
Port NO 5005
Communication
Password 200409
Communication
Stopbit 1
27
-
7/27/2019 BC-2028 Manual
29/50
User Guide
Device ID: the number of the machine, ranged from 1-255Baud rate: the communication speed of the
communication with the computer. There are three choices:9600, 38400,115200. High speed communication is fast, andthe RS232 communication is recommended. Low speedcommunication is slow, RS485 communication is
recommended.IP address: By default, the IP is 192.168.1.201. You may
change according to practical requirement.Port No: By default is 5005 . Work with IP Address.Subnet mask: By default is 255.255.255.0.Default gateway: By default is 192.168.0.1.Password: the system default communication password is
200409, which may be defined
Warning: RS485 communication in the outdoorenvironment, the lightening protection device is required.
4.3. Log SetupAccess Log Opt, the following message appears:
Log Setup
M-Log Wrn No
Communication
IP Address
Communication
Subnet mask
Communication
Default gateway
28
-
7/27/2019 BC-2028 Manual
30/50
Alarm Attendance Log: when the remainder log capacity
reached set numerical value, it will automatically sound awarning that logs were filled.
Recheck Minute: Set within compass (Unit: minute). Someonesenrollment has enrolled, then, the log twice was not displayed in thesystem.
4.4. Lock SetEnter the Lock Set menu; the screen shall display the
following information:
Log SetupW-Log Wrn 1000
Log Setup
Re-Verify No
Lock Set
Define TZ
Lock Set
User Acc Opts
Lock Set
GRP TZ Define
Lock Set
GroupMatch
29
-
7/27/2019 BC-2028 Manual
31/50
User Guide
Five main functions in Access Options:Time Zone Define: indicate the door unlocked time in
every day of the week
User Access Options is to setup the unlock time andAccess Comb by the user;
GRP TZ Define is GRP TZ, time zone station the group;GroupMatch is to define variant unlock combinations,
every combination consists different groups;Unlock: Fingerprint startups lock time;
In this menu, the user can define the corresponding
functions.For details of the operation, please refer to the
Unlock
OpenTime 5
Lock SetUnlock
Unlock
Time 3
Lock Set
Alrm Release
Lock Set
Warn Time 1
30
http://var/www/apps/conversion/tmp/scratch_6/F4%E9%97%A8%E7%A6%81%E6%93%8D%E4%BD%9C%E6%8C%87%E5%8D%97%E8%8B%B1%E6%96%87.dochttp://var/www/apps/conversion/tmp/scratch_6/F4%E9%97%A8%E7%A6%81%E6%93%8D%E4%BD%9C%E6%8C%87%E5%8D%97%E8%8B%B1%E6%96%87.dochttp://var/www/apps/conversion/tmp/scratch_6/F4%E9%97%A8%E7%A6%81%E6%93%8D%E4%BD%9C%E6%8C%87%E5%8D%97%E8%8B%B1%E6%96%87.dochttp://var/www/apps/conversion/tmp/scratch_6/F4%E9%97%A8%E7%A6%81%E6%93%8D%E4%BD%9C%E6%8C%87%E5%8D%97%E8%8B%B1%E6%96%87.dochttp://var/www/apps/conversion/tmp/scratch_6/F4%E9%97%A8%E7%A6%81%E6%93%8D%E4%BD%9C%E6%8C%87%E5%8D%97%E8%8B%B1%E6%96%87.doc -
7/27/2019 BC-2028 Manual
32/50
5 System Information
Access [Menu] to Sys Info, press [OK], the followingappears:
It is plays user numbers, password numbers, fingerprintnumbers, manager and log numbers in the screen.
System Info
User 3000
173
8046System Info
Manager 5
System Info
Work Log 800000
System Info
Mgr Log 0
System Info
Fingerprint 3000
System Info
Password 3000
31
-
7/27/2019 BC-2028 Manual
33/50
User Guide
6 Trouble shooting
1. CleaningFrom time to time, the optical platen, the keypad anddisplay window require cleaning. Since working environmentsdiffer, it is not possible to define when cleaning should beperformed. Following is guide:
Figure Error: Reference source not found-2 Cleaning Schedule
Item Cleaning Frequency
Keypad anddisplay window
Cleaning when visibly dirty and hardto read. See cleaning the keypad anddisplay below.
Optical platenDo not over clean. The platen is
designed to work under greasy or dirtyconditions.
However, do clean if the platen isobstructed or people are reportingdeteriorating performance. Seecleaning the Optical Platen below.
2. Cleaning the Keypad and DisplayTo clean the keypad and display, use the same cleaningproducts as for the platen, and wipe dry.
3. Cleaning the Optical PlatenClean the optical platen as follows:(1) If dusty or gritty, first blow on the platen to clean off any
loose particles.(2) Spray on a light coating of a window cleaning product or
other similar neutral detergent.Warning: Do not use any other cleaner or the platen may
become damaged.(3) Using a non-abrasive and lintine, pat dry. Be careful not
to scratch the platen. If lint particles adhere to the platensurface, below them off when the platen is dry
32
-
7/27/2019 BC-2028 Manual
34/50
7 User Acc Opts Guide
7.1. Product Features
Arbitrary time zone and grouping access control function
Manageable access control and attendance recordfunctions
Internal integrated single-door controller, easy to install
Compatible with doorbell
Panel equipped with red and green status indication LED,
water resistance keyboard with white LED light Removal alarm function, voice hint when identification
Adopt standard access control bracket installation
Network management software, easy to manage multi-setof equipments
Compatible with BioID T&A Software management system
Wireless Modem (optional)
Proximity ID card reader (optional)
Wiegand 26 standard output (optional), compatible withother door controllers
Adopt High Speed and large capacity algorithm of BioID
7.2. Basic Concepts
Basic concepts in Access Options function:
Access Options: is the settings of registered usersunlocking time zone and unlocking combination.
Define TZ: is the definition of everyday Time Zone thatcan unlock door in one week.
Grouping (GRP): divides registered users into severalgroups, is easy and convenient to manage.
Effective Time Zone: is the definition of Time Zone inwhich user currently passes verification.
Group Time Zone: is used to set group unlocking
33
-
7/27/2019 BC-2028 Manual
35/50
User Guide
time.
User Time Zone: is user to set users unlocking time.
Access Comb (Unlocking combination): definesdifferent unlocking combinations, and eachcombination is composed of different groups.
Lock (Time duration of lock drive): fingerprint scannercontrols the time to open electronic lock.
7.3. Access Options
Press MENU key and enter main menu.Press UP and DOWN keys and select Setup. PressOK to enter Setup menu.
Press UP and DOWN keys and select Lock Set. PressOK to enter setting menu of Access Options function, andscreen information displays as follows:
Lock Set
Define TZ
Lock Set
User Acc Opts
Lock Set
GRP TZ Define
Lock SetAccess Comb
Unlock
OpenTime 5
Lock Set
Unlock
Unlock
Time 3
34
-
7/27/2019 BC-2028 Manual
36/50
Lock Set has 7 main functions:Time Zone is the minimum time definition zone unit in
Access OptionsUser Acc Opts is to process correlative setting according
to users requirement.GRP TZ Define is group Time Zone, and configure group
time zone.Access Combdefines different unlocking combinations, and
each combination is composed of different groups.Unlock fingerprint scanner controls the time to open
electronic lock.
In this menu, user can define and set each function.
7.3.1. Brief Introduction to Access Options
Access Options function setting is the settings of registeredusers unlocking time zone and unlocking combination.
Each users settings are composed of one belonged grouping,use group time zone and user time zone. Grouping is to divide
users into several groups, such as group 1, group2, etc. In grouptime zone, user can select maximum three time zones alreadybeing set. Relationships among these three time zones are OR(i.e. it is only need to satisfy any one of these three time zones). Inuser time zone, user can select maximum three time zones alreadybeing set. Relationships among these three time zones are alsoOR. For details of relationship between use group time zone anduser time zone, please refer to User Access Options .
Simply put, conditions of registered user can unlock doorare:
1: The group that user belongs to should be in unlockingcombination (also this group can be in unlocking combinationwith other groups, but it is required to unlock door together withthem).
2: Current unlocking time should be in any effective time
zone in user time zone.
35
-
7/27/2019 BC-2028 Manual
37/50
User Guide
System defaults that new registered user belongs to group1, default grouping combination is group 1, and default grouptime zone is 1. Under the condition that group 1 and time zone1 are in factory default status, new registered user defaults inunlocking status (if user changes correlative setting of AccessOptions, system will change according to users modification). Ifthe grouping that user belongs to does not include in groupingcombination setting, then user can only record attendance andcannot unlock door.
7.3.2. Verification Flow of Access Options
36
-
7/27/2019 BC-2028 Manual
38/50
37
-
7/27/2019 BC-2028 Manual
39/50
User Guide
7.4. Function Description7.4.1. Definition of Time zone
Time zone is the minimum time zone unit of AccessOptions. Whole system can define maximum 50 time zones. 7time regions (i.e. one week) can be set in each time zone. Eachtime region is effective time zone in 24 hours of a day. Eachuser can set maximum 3 time zones. Relationships amongthese three time zones are OR. It is effective as long as thetime to verify can meet one of these three time zones. Eachtime region format of time zone is HH:MM-HH:MM, i.e. the
format is according to 24-hour mode and accurate to minute.
End-time less than start-time (23:57-23:56) represents all-day forbidden. End-time larger than start-time (00:00- 23:59)represents effective in this region.
Effective time zone for user to unlock: all-day open (00:00-23:59) or end-time larger than start-time in time zone.
Note: System defaults that time zone of serial number 1 is all-dayopen (i.e. new registered user default can unlock door).
1 Enter Define TZ and screen displays as follows:
Press OK to enter setting of time zone 1 and screendisplays as follows:
38
-
7/27/2019 BC-2028 Manual
40/50
Access Options
Definition of time zone 1 above is all-day open, i.e. factorydefault status.
2 For example:Time zone can be redefined, i.e. definition of time zone 1
is:Saturday and Sunday are break, and not allow to enter.Working time of Monday to Friday allow to enter.Working time: 08:30-18:00
Setting is as follows
39
-
7/27/2019 BC-2028 Manual
41/50
User Guide
On analogy of this, multi time zones can be defiedaccording to practical requirements. Whole system can define
maximum 50 time zones.
7.4.2. Definition of Grouping Function
Grouping function can divide users into group, and canalso combine different groups into different unlockingcombinations, which are easy and convenient for groupingmanagement of Access Options. And all that, the grouping
function can combine many unlocking combinations. Systemdefines 5 groups: group 1, group 2, group 3, group 4 and group5. New registered user default belongs to group 1, but the usercan be relocate into other group.
Select serial number of Time Zone already being set ingroup Time Zone .New registered user default uses time zone ofgroup 1. But after user resets the belonged group, the user usesdefault time zone of correlative group. So default time zone of
each group should be defined first.For details of use group timezone, please refer to User Access Options.
40
-
7/27/2019 BC-2028 Manual
42/50
Access Options
Note: time zone of system defaults that group 1 selects serialnumber 1 oftime zone. (i.e. new registered user default can unlock door)
a) Enter GRP 1 TZ Define and screen displays asfollows:
Press OK to enter.
There are 3 time zones in GRP TZ Define. Relationshipsamong these 3 time zones are OR.
Group 1 is effective in time zones of 1, 8 and 40, and canalso select other defined time zones.
b) Enter GRP 2 Dflt TZ and screen displays asfollows:Setting of time zone of group 2:
Press OKto enter.
41
-
7/27/2019 BC-2028 Manual
43/50
-
7/27/2019 BC-2028 Manual
44/50
Access Options
of belonged group (group time zone should be set inadvance).
2 If User Time zone is changed, then use group time zone
automatically change to No.
2. Example of setting:
The following example is to set user 00001 and 00002to group 1 and group 2, respectively.
A. Enter setting interface of serial number 00001, and
screen displays as follows:
Press OK to enter setting menu ofuse group time zone.Press UP and DOWN keys and select Yes. Screendisplays as follows:
User of serial number
43
-
7/27/2019 BC-2028 Manual
45/50
User Guide
00001:Users belonged grouping is 1, it uses time zone of group
1 (serial number of user time zone is serial number of grouptime zone).
User 00001 is effective in time zones of 1, 8 and 48.B. Enter setting interface of serial number 00002, and
screen displays as follows:
Press OK to enter.If serial number of user time zone is 1 or 20, then use
grouptime zone automatically change to No.
User of serial number 00002:Users belonged grouping is 2, it uses user time zone and
does not use group time zone, i.e. it is effective in time zones of1 and 20.
44
-
7/27/2019 BC-2028 Manual
46/50
Access Options
When user wants to use group time zone, then selectYes. In user time zone, serial number of group time zone willbe automatically assigned the value of serial number of grouptime zone. Contrariwise, if user wants to use user time zone,just directly modify the serial number in user time zone and usegrouptime zone will automatically change to No.
7.4.4. Access Comb
Unlocking combination is the direct representation ofcontrolling unlocking. For example, if user wants that all
registered users cannot unlock, then the user can set all 10unlocking combinations to null.
Unlocking combination definition is to define differentunlocking combinations, and each combination is composed ofdifferent groups. Unlocking combination directly uses groupnumber and does not consider user verification sequencebetween each group. For example 123 represents group 1,group 2, group 3 and at least one user in each group
congregates and passes verification together, then door can beunlocked. 4 represents that after individual user in group 4passes verification, then door can be unlocked. System cansimultaneously define maximum 10 unlocking combinations. Itis required that only one of them passes verification.
Note: Unlocking combination of system initial default setting is 1
(i.e. new registered user default can unlock door).
Press MENU and enter main interface.Select Options and press OK to enter setting menu.Select Access Options and press OK to enter menu.Select Unlocking Combination Definition to enter
Unlocking Combination and screen displays as follows:
45
-
7/27/2019 BC-2028 Manual
47/50
User Guide
When do not process setting yet (i.e. factory defaultstatus), system defaults that group 1 is unlocking combination 1and others are null.
If do not want to allow all users to unlock door, then set 10unlocking combination all to null.
If only want to allow some groups to unlock door together,
then set these groups in unlocking combination definition.
1) For example:
46
-
7/27/2019 BC-2028 Manual
48/50
Access Options
From above combination setting, it can be seen that:123 is a combination.4 is a combination.24 is a combination.45 is a combination.15 is a combination.
Combination 1: when personnel of group 1, group 2 andgroup 3 are all on the scene and the time zone is effective in
which at least one user in each group passes verificationtogether, then door can be unlocked.
Combination 2: only one of personnel belonged to group 4is on the scene, then door can be unlocked.
Combination 3: when personnel of group 2 and group 4 areall on the scene and the time zone is effective in which at leastone user in each group passes verification together, then doorcan be unlocked.
Combination 4: when personnel of group 4 and group 5 areall on the scene and the time zone is effective in which at leastone user in each group passes verification together, then doorcan be unlocked.
Combination 5: when personnel of group 1 and group 5 areall on the scene and the time zone is effective in which at leastone user in each group passes verification together, then doorcan be unlocked.
47
-
7/27/2019 BC-2028 Manual
49/50
User Guide
Note: time zones that cannot pass verification User time zone does not select serial number of time zone.
Group time zone does not select serial number of time zone. Time in which user passes verification does not include any time
zone that is set by user.
Time zone is defined as forbidden.
Note: If time zone that user sets is the time zone thatcannot pass verification.
When meet combination 2 above, user who displays prompt ofInvalid Time zone Access cannot unlock door, but can record
attendance. (If there is user in group 4 who can meet unlockingcondition, then combination 2 can unlock door)
When meet combination 1, 3, 4, and 5 above, user who displays
prompt of Invalid Time zone Access cannot unlock door, but canrecord attendance.
2) For example: one bank treasury requires that 3
people are all on the scene to open the door oftreasury. Detailed settings are as follows:
These 3 people belong to group 2, group 4 andgroup 5 respectively, and have the right to unlock doorwithin the same time zone. Select Group 1 andpress OK to enter edit status. Press digit keys toenter 245. Then press ESC to exit and save settinginterface.
Note: When combination 245 is defined, then usercannot define 24, 25, 45 as combination.
48
-
7/27/2019 BC-2028 Manual
50/50
Access Options
Technical specifications
User capacity 3000Transactioncapacity
80000
Verification mode 1N (recommended) or 11
Access ControlFunction
50 Time Zone5 Grouping10 Access Combsupport multi-fingerprint verification access,Fingerprint or password validating mode,
Electro control Relay output 3A/12VDC
Attendance
FunctionOptional Support BioID attendance software
Else inputA group of door-magnetism input, a group ofbutton of open the door input, a group ofdoorbell input
Communications TCP/IPRS485RS232
Wiiegand output Wiegand26 outputOptional
keyboard andDisplay
4 row 122*32 dots display ,4*4 keypad, whitebacklight
Power12V DC, Stay current50 mA, work current400mA
Validating speed =1 s (full of 3000 fingerprint enrolled)
Sensor Uncoated BioID optical sensor
FRR =0.001%
FAR =0.0001%
OperatingTemperature
0C - 45C
Operating Humidity 20%-80%
Lcd languageEnglish Simplified Chinese TraditionalChineseother languages optional
Voice language English, Chinese, any other languages optional
OEM Supply OEM Made
Size 85L*45W*180Hmm