Baumer BQ · Chemicals Refinery Nuclear Aerospace Fertilizer Petrochemicals Pharmaceutical Case &...
Transcript of Baumer BQ · Chemicals Refinery Nuclear Aerospace Fertilizer Petrochemicals Pharmaceutical Case &...
Chemicals
Refinery
Nuclear
Aerospace
Fertilizer
Petrochemicals
Pharmaceutical
Case & measuring system in ss
Dry or liquid filled
Accuracy up to 1.0% F. S.
Standard followed in general EN 837 - 3
Standard Version : 150 mm
Baumer
Page 1 / 2
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
www.baumer.com
Special Features
GOST - R
GOST
Specifications
Application
:
:
:
:
:
:
:
:
Temperature effect :
The variation of indication caused by effects of temperature is to be
calculated by below formula; which is to be added in the specified
accuracy while measurement :- Formula : ± 0.08 x (t2 - t1) % of F. S.
where t1 = reference temperature (+20°C) and t2 = ambient
temperature in °C.
Differential Pressure GaugeBellow type
BQ
Pharmaceutical
Power
Cement
Sugar
Food & beverages
Pulp
Paper & allied process industries
Dimensions - standard version
Accuracy
Ambient temperature
Process temperature
Static pressure
Over pressure limit
±1.6% of F. S. for ranges up to 1 bar ±1.0% of F. S. for ranges 1 bar to 6 bar
- 25°C to + 65°C
Max 100°C2 6 kg/cm up to ranges 0.6 bar
2 25 kg/cm for ranges 1 bar to 2.5 bar2 40 kg/cm for ranges 4 bar to 6 bar
130% of Max. Scale Value
Case & Bezel
Bellow
Process connection
Movement
AISI 304 SS (Bayonet Type)
AISI 316L SS
½” NPT(M) x 2 Nos.
AISI 304 SS
Protection
Dial
Pointer
Window
Gasket & Filling Plug
Blow Off Disc
Scale Amplitude
IP 65
Aluminum,
black graduation on white background
Aluminum, black coloured,
Micrometer Zero Adjustable
Shatterproof / Safety Glass
Neoprene
Neopreneo o 80 to 270 (Depends on Range)
:
:
:
:
:
:
:
:
:
:
:
Accuracy
Ambient Temperature
Process Temperature
Window
Dampening Liquids
Other Features
±1.0 % of F. S.
Maximum 65°C
Maximum 65°C
Plexi Glass
Glycerin 99.7%
Refer Specification of Standard Version
Glycerine filled version (option PY)*
*Suitable for ranges 1 bar to 6 bar
:
:
:
:
:
:
TYPE 1
TYPE 6
Notes : • Drawings are not to scale. • All Dimensions are in mm.
• NS = Nominal Size
2200(With Box)
Weight in gram
221491619615
EA B ØC
150
NS ØD
90
F
6 186
ØG ØH ØI J
168 060
BQ model bottom entry with surface mounting
2000(With Box)
Weight in gram
901491619915
EA B ØC
150
NS ØD
200
F
250 220
G H I J
69 060
ØK
186
ØL
168
2Note : We offer Pressure, Vacuum and Compound ranges in Scales like kPa, MPa, bar, psi, kg/cm & Dual Scale like kPa with psi, kPa with 2bar, bar with psi or scales as per the requirement can be provided on request. Following are the example tables for kg/cm & psi scales
Baumer
Range Table
Code
Nominal Size
Basic Model
Page 2 / 2
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
www.baumer.com
BQ
H
150 mm
Differential Pressure GaugeBellow type
Pressure range (Single Scale)
Note : Other Scale are available on customer request.
Low Pressure
0/4000
0/6000
mmWC
0/1
0/1.6
kg/cm²
Accessories
Manifolds
High Pressure
0/2
0/2.5
kg/cm²
0/4
0/6
kg/cm²
(Refer Individual Datasheet for complete specifications)
Type of Mounting
1
6
Refer range table
Optional Extras
Range
Wall / surface / projection mounting with bottom entry
2" pipe / yoke mounting with bottom entry (mounting bracket will be provided of steel epoxy painted.)
Process Connection
½" NPT (M) x 2 Nos.(Standard) 4NM
Bellow
GU AISI 316L SS (Standard)
Note : Connections like Metric/ PT/ PF/ Flaired/ UNF/ G/ R etc can be provided on request. Consult factory for price & delivery.
AISI 316 SS case & bezel
Dampening liquid glycerin
Dampening liquid silicon oil**
Custom designed dial
Dial tag marking
SS tag plate
Maximum reading pointer with plexi glass
(for dry version)*
PS
PY
QA
RH
SW
SX
SJ
* For ranges 2.5 kg/cm² and above. ** BOD Gasket & Plug Viton. Suitable for ranges 1 bar to 6 bar
# Material test certificates will be provided for wetted parts only with chemical composition testing. For others, please consult factory.
Note : For selection of Diaphragm Seals, refer individual data sheets.
(The capillary length shall be maximum up to 3 meters & range shall be above 1 kg/cm².)
TF
PU
PW
GH
JU
FN
RZ
Conformity as per NACE standard
Calibration certificate traceable to
National / International standards
Five point calibration certificate
Material test certificates#
2” pipe/yoke mounting bracket & ‘U’ clamp (AISI 304 SS)
2” pipe/yoke mounting bracket & ‘U’ clamp (AISI 316 SS)
Toughened glass
2Ordering Example: BQ . X . X . XXX . XX . 0/2 kg/cm . XX
For other optional items, please contact factory for delivery and minimum quantity of order.
Note : Specifications and dimensions given in this product catalogue represents the state of engineering at the time of printing .
Modifications may take place and materials specified may be replaced by others without prior notice.
BQ
X
XXX
0 / 22kg/cm
XX
X
XX
How To Order Example