    Basic Specifcations

    Horizontal Dimensions

    Ratedcapacity

    (kg)

    Ratedspeed

    (m/sec)

    Numberof

    persons

    Codenumber

    Doortype

    Counter-weight

    position

    Car internaldimensions

    (mm)AABB

    Minimum hoistwaydimensions

    (mm)AHBH/car

    Minimum machineroom dimensions

    (mm)AMBM/car

    Entrancewidth(mm)

    JJ

    Vertical Dimensions

    Hoistway Section

    Hoistway Plan

    [Terms o the table] The contents o this table are applied only to standard specifcations without counterweight saety. Please consult our local agents or other specifcations.[Note]*1 Some specifcations require more than 2500mm as a minimum oor height. Please consult our local agents i the oor height is less than entrance height HH + 700mm.

    1.0 601.5 30

    30

    90

    9036120309036120

    1.75

    2500 *1

    P6 6 450 1400850

    14001030P8 8 550

    14001100P9 9 600

    14001250P10 10 700

    14001350P11 11 750

    16001350P13 13 900

    16001500

    P15 15 1000

    P17 17 1150

    P20 20 1350

    18001300

    11002100

    18001500

    20001350

    18001700

    20001550

    Rear

    Rear

    Side

    Rear

    Rear

    Side

    Side

    17501400

    21001200

    17501590

    200032501.0

    1.0

    25002900

    20003350

    20003600

    4400 1360

    4560 1410

    2200

    4630 1410

    1550

    1900

    Ratedspeed

    (m/sec)

    Rated capacity(kg)

    Maximumtravel

    (m)TR

    Maximumnumber of

    stops

    Minimum overhead(mm)

    OH

    Minimumpit depth

    (mm)PD

    Minimummachine room

    clear height(mm)HM

    Minimumfoor to foor

    height(mm)

    2 10 0 13 80 2 50 0 30 00

    1.5

    1.75

    1.0

    1.5

    1.75

    1 75 0 16 60 2 00 0 35 50

    1.0

    1.5800

    1.75

    2 10 0 14 50 2 50 0 30 00

    1.0

    1.5

    1.75

    17501810

    21001600

    CO

    2S

    CO

    Side

    Rear

    Rear

    Rear

    Rear

    Rear

    Rear

    Rear

    Rear

    Side

    Side

    Side

    Side

    Side

    Side

    Side

    Side

    Side

    20003650

    25003100

    200036001.0

    1.5

    1.75

    1.0/1.5/1.75

    1 75 0 19 10 2 00 0 37 00

    2 10 0 17 00 2 50 0 31 00

    2 05 0 19 10 2 10 0 37 00

    24001730900

    900

    1000

    1100

    1000

    1000

    1100

    25003100

    2 05 0 20 60 2 10 0 38 50

    2 40 0 18 80 2 50 0 32 00

    2 25 0 18 60 2 30 0 37 00

    26001680

    18502530

    26003000

    23804230

    2 25 0 21 10 2 30 0 39 00

    1.0

    1.5

    1.75

    2.0

    2.5 2 65 0 18 80 2 90 0 31 00

    2 45 0 19 60 2 50 0 34 502 85 0 17 30 3 10 0 30 00

    2 25 0 23 10 2 30 0 41 00

    2 65 0 20 80 3 00 0 32 00

    2 45 0 21 60 2 50 0 36 50

    2 85 0 19 30 3 20 0 28 00

    2.0

    2.5

    1615

    * Based on, but not ully complying with the Building Standard Law o Japan, 2009.

    Note: Hoistway section or counterweight side drop is slightly dierent rom this fgure.

    Machineroomc

    learheight:HM

    2200

    Overhead:OH

    Entranceheight:HH

    2100(standard)

    Ceilingheight

    2200(standard)

    Travel:TR

    Minimumf

    oortofoorheight

    Pitdepth:PD

    Hoistway width: AH

    Entrance

    width: JJJJ

    Car internalwidth: AA AA

    Carinternal

    depth:BB

    Hoistwaydepth:BH

    Machine room width: AM

    Machineroomdepth:BM

    Control

    Panel

    Power-receiving box

    (by owner)

    Lighting outlet (by owner)

    Power outlet (by owner)

    Accessdoor

    Ventilation

    grill

    Ventilator

    (by owner)

    Width=700

    Height=2000

    Shown for CO doorsCounterweight rear drop

    AH

    JJ

    AA

    Shown for CO doorsCounterweight side drop

    Shown for CO doorsCounterweight rear drop

    Shown for CO doorsCounterweight side drop

    AM

    BM

    Control

    Pa nel

    Power-receiving box

    (by owner)

    Power-receiving box (by owner)

    Lighting outlet (by owner)

    Lighting outlet (by owner)

    Power outlet (by owner)

    Power outlet (by owner)

    Accessdoor

    Shown for 2S doorsCounterweight side drop

    Shown for 2S doorsCounterweight side drop

    Ventilation

    grill

    BM

    Ventilation

    grill

    Ventilator

    (by owner) Ventilator(by owner)

    Width=700

    Height=2000

    BB

    BH

    Machine RoomPlan

    [Terms o the table] The contents o this table are applied to standard specifcations only. Please consult our local agents or other specifcations. Rated capacity is calculated as 65kg per person, as required by the Building Standard Law o Japan, 2009. CO: 2-panel center opening doors, 2S: 2-panel side sliding doors. Minimum hoistway dimensions (AH and BH) shown in the table are ater waterproofng o the pit and do not include plumb tolerance. This table shows the specifcations without the freproo landing door and counterweight saety.

    Applicable Standards

    NEXIEZ complies with Mitsubishi Electric standard*.

    For details o compliance, please consult our local agents.

    TR 80