Ballyteigue Bannow Water Management Unit Action Plan Name0000. Ballyteigue Bannow Water Management...
-
Upload
brianna-tate -
Category
Documents
-
view
214 -
download
1
Transcript of Ballyteigue Bannow Water Management Unit Action Plan Name0000. Ballyteigue Bannow Water Management...
Ballyteigue Bannow Water Management Unit Action Plan
Name0000.Ballyteigue Bannow Water Management Unit
Area 644 km2
River Basin District South Eastern RBD
Main Counties Wexford
Protected Areas
River Barrow and River Nore SAC, Ballyteigue Burrow SAC, Bannow Bay SAC, Tacumshin Lake SAC.Ballyteigue Burrow SPA, Bannow Bay SPA, Tacumshin Lake SPA.2 drinking water abstractions from Owenduff River and stream at Haresmead. Duncannon Bathing water.Bannow Bay and Waterford Harbour Shellfish water.
Sectoral Total Phosphorus Source (This does not imply impact)
01020304050607080
%
Ballyteigue/Bannow Water Management Unit Action Plan
STATUS/IMPACTS
Overall status 36 RWB - 19 Good, 10 Moderate, 7 Poor. No lakes. 1 Coastal Waterbody - Bannow Bay
Status elements
Overall status dictated by Q-score, apart from 2 waterbodies, where Phys Chemical drives good status. Status for 22 WBs was extrapolated. Chemical Status passes in both monitored WBs - Owenduff and Duncormick Rivers.
Possible Impacts - EPA Water Quality 2004
BATTLESTOWN STREAM - SE_13_758, Status 2009 - Good (Based on Q value 4) –
Satisfactory following improvement since last study.
BEGERIN STREAM - (SE_13_215, Status 2009 - Good (Based on Q value 4)) – Satisfactory.
BRIDGETOWN, WEXFORD - (SE_13_692, Status 2009 - Good (Based on Q value 4))
Improvement in lower reaches with both locations satisfactory in 2007.
CLERISTOWN STREAM - (SE_13_145, Status 2009 - Good (Based on Q value 4)) –
Satisfactory with significant improvement since previous study.
COROCK - (SE_13_749, Status 2009 - Moderate (Based on Q value 3-4)) – Satisfactory at all but last location where faunal response indicated enrichment.
DUNCORMICK - (SE_13_745, Status 2009 - Poor (Based on Q value 3) - Satisfactory at all locations except downstream from Taghmon where moderately polluted.
MULMONTRY - (SE_13_394, Status 2009 - Poor (Based on Q value 3)) –Unsatisfactory at all three locations due to pollution. Deterioration at final location. Uppermost location is immediately upstream of the intake point for a public water supply.
OWENDUFF, WEXFORD - (SE_13_754, Status 2009 - Good (Based on Q value 4-5)) -
Satisfactory at both locations representing some improvement.
TINTERN ABBEY STREAM - (SE_13_756, Status 2009 - Poor (Based on Q value 3)) –
Unsatisfactory with a moderate degree of siltation.
PRESSURES/RISKS
Nutrient sources
91% of TP is Diffuse, 74% of which is from Agriculture
Point pressures
17 WWTPs: Adamstown, Ballycullane, Ballyhack, Barntown/Ballyhine, Bridgetown, Carrick-on-Bannow, Clongeen, Duncannon, Fethard-on-Sea, Foulkesmills, Kilmore Quay, Lady's Island, Taghmon, Tomhaggard (St. Annes), Tomhaggard (St. James), Newbaun, Tellarought.
3 WTPs: Aughnagroagh Bridge, Taylorstown, Mayglass.
45 Section 4s: Hotel/Restaurant, Nursing Home, 2 Hotels, Quarry, 2 Building Contractors, 2 Creameries, Supermarket, Photographer, Electrical Contractor, Retail Company, 32 Private Companies.
1 IPPC: Manufacturer.
Wastewater Treatment Plants (WWTP) and Industrial Discharges
15 WWTP's At Risk: Adamstown, Arthurstown, Ballycullane, Bridgetown, Carrick-on-Bannow, Clongeen, Fethard-on-Sea WWTP, Foulkesmills, Taghmon, Duncormick ,Ballyhack, Kilmore Quay, Wellingtonbridge, Duncannon, Tomhaggard (St. Annes) – Refer to Measures table
WWTP – Upgrade proposed Tomhaggard(St. Annes) in WSIP 2007 - 2009
Quarries, Mines & Landfills
There are 9 quarries in this WMU
Agriculture The majority of the area of the WMU is at risk from Agriculture
On-site systems
There are 9984 septic tanks in this WMU, 1984 septic tanks in 5 river water bodies are posing a risk to water quality due to their density, location and unsuitable hydrogeological conditions.
Forestry No waterbodies at risk from forestry
Dangerous substances
No waterbodies at risk from Dangerous Substances.
Morphology 3 Waterbodies at risk due to channelisation -SE_13_2, SE_13_254 and SE_13_245 - Ballyteigue Bannow Drainage Scheme
Abstractions 14 abstractions; 1 waterbody at risk - SE_13_754
Other
River Status
High
Good
Moderate
Poor
Bad
Yet to be determined
Ballyteigue/Bannow Water Management Unit Action Plan
OBJECTIVES
Restore/Protect 2015
26 water bodies
Alternative Objectives
Extended Deadlines – 10 water bodies with 2021 deadlines
New Modifications or Development – none requiring alternative objectives at present.
HMWB/AWB - none
SELECTED ACTION PROGRAMMENB All relevant basic measures, general supplementary measures and SEA mitigation measures apply
Point Sources WWTP - See Point Source Discharge Table to the right.
INDUSTRY - Examine the terms of discharge authorisations to determine whether they require review for the purpose of compliance with water body objectives including protected area objectives and environmental quality standards.
Diffuse Sources Good Agricultural Practice Regulations and Enforcement.
ON-SITE SYSTEMS - The 1984 at risk septic tanks are to be prioritised for inspections. Subsequent upgrade or connection to municipal systems depends on inspection and economics tests.
Other MORPHOLOGY - All 3 waterbodies at risk will require investigation to determine impact of channelisation
ABSTRACTIONS - Protection of drinking water, abstraction control and future licensing.
Measures included in Shellfish Pollution Reduction Programmes under the Shellfish
Directive.
Local Authority Needs Assessment (2007 -2009) identified the following upgrades - Kilmore Quay, Curracloe, Duncormick Sewerage Scheme, Arthurstown Sewerage Scheme and Taghmon WWTP.
FUTURE DEVELOPMENT
Future Pressures and Developments
Throughout the river basin management cycle future pressures and developments will need to be managed to ensure compliance with the objectives of the Water Framework Directive and the Programme of Measures will need to be developed to ensure issues associated with these new pressures are addressed.
Point Source Discharge County Priority Measure (Capital Works)
Taghmon WWTP Wexford 1 Increase capacity of treatment plant.
Taghmon WWTP Wexford 2 Provide tertiary treatment or relocate outfall.
Arthurstown Wexford 1 Increase capacity of treatment plant.Ballyhack Wexford 1 Increase capacity of treatment plant.Duncannon Wexford 1 Increase capacity of treatment plant.Wellington Bridge Wexford 1 Increase capacity of treatment plant.
Point Source Discharge County Priority Measure (Investigation before Capital Works)
Ballycullane Wexford 3Investigate the need for increase in capacity of treatment plant.
Clongeen Wexford 2Investigate the need for increase in capacity of treatment plant.
Duncormick Wexford2
Investigate the need for increase in capacity of treatment plant.
Fetherd-on-Sea WWTP Wexford 3Investigate the need for increase in capacity of treatment plant.
Kilmore Quay Wexford 2Investigate the need for increase in capacity of treatment plant.
Tomhaggard(St. Annes) Wexford 2Investigate the need for increase in capacity of treatment plant.
Point Source Discharge County Priority MeasureArthurstown Wexford 1 Commence implementation of the Pollution
Reduction Programme for Shellfish watersBallyhack Wexford 1 Commence implementation of the Pollution
Reduction Programme for Shellfish watersDuncannon Wexford 1 Commence implementation of the Pollution
Reduction Programme for Shellfish watersWellingtonbridge Wexford 1 Commence implementation of the Pollution
Reduction Programme for Shellfish watersPoint Source Discharge County Priority Measure
Adamstown Wexford 1 Implement an appropriate performance management system
Bridgetown, Wexford Wexford 1 Implement an appropriate performance management system
Carrick-on-Bannow Wexford 1 Implement an appropriate performance management system
Point Source Discharge County Priority MeasureFoulkesmills Wexford 3 Investigation of CSO's
Point Source Discharge County Priority MeasureAdamstown Wexford 3 Ensure capacity of treatment plant is not Carrick-on-Bannow Wexford 3 Ensure capacity of treatment plant is not
River Data Ballyteigue/Bannow Water Management Unit Action Plan
Member State Code
Monito
red Y
(E
xtra
pola
ted N
)
Donor W
ate
rbody
Macro
inverte
bra
tes (Q
)
Fre
shW
ate
r Pearl
Musse
l
Fish
Phyto
benth
os
(Dia
tom
s)
Morp
holo
gy
Specifi
c Polu
tants
Physio
-chem
ical
Eco
logica
l Sta
tus
Chem
ical S
tatu
s
Specia
l Are
a o
f Conse
rvatio
n
Specia
l Pro
tectio
n
Are
a
Nutrie
nt S
ensitiv
e
Wate
rs
Drin
kin
g W
ate
r
Obje
ctive
Date
obje
ctive to
be a
chie
ved
SE_13_118 N SE_12_1305 M GES 2015
SE_13_145 Y G G GES 2009
SE_13_164 N SE_13_166 G GES 2009
SE_13_166 Y G H G GES 2009
SE_13_2 Y G G GES 2009
SE_13_215 Y G G GES 2009
SE_13_242 N SE_13_758 G Y GES 2009
SE_13_243 N SE_13_758 G Y GES 2009
SE_13_245 N SE_13_254 G Y Y GES 2009
SE_13_251 N SE_12_1305 M Y Y GES 2015
SE_13_254 Y G G Y GES 2009
SE_13_259 N SE_12_1305 M Y GES 2015
SE_13_285 N SE_13_166 G GES 2009
SE_13_394 Y P G P Y GES 2021
SE_13_397 Y G H G GES 2009
SE_13_407 N SE_12_2385 G GES 2009
SE_13_410 N SE_13_394 P GES 2021
SE_13_438 N SE_13_145 G GES 2009
SE_13_504 N SE_12_1305 M GES 2021
SE_13_511 N SE_12_1305 M GES 2015
SE_13_516 N SE_12_2385 G GES 2009
SE_13_547 Y M H M GES 2021
SE_13_613 N SE_13_547 M GES 2021
SE_13_646 N SE_13_215 G GES 2009
SE_13_662 N SE_13_756 P GES 2021
SE_13_671 N SE_12_2385 G GES 2009
SE_13_675 N SE_13_756 P GES 2021
SE_13_676 N SE_12_1305 M GES 2015
SE_13_692 Y G G G GES 2009
SE_13_703 N SE_12_1305 M GES 2015
SE_13_745 Y P H M P G GES 2021
SE_13_749 Y M M Y GES 2015
SE_13_754 Y G H H H G G Y GES 2009
SE_13_756 Y P H P GES 2021
SE_13_758 Y G G Y GES 2009
SE_13_762 N SE_13_756 P GES 2021
IE_SE_BallyteigueBannow
Biological Elements Supporting Elements Protected Areas
This table outlines water body information including status and a breakdown of its elements, protected areas, objectives and timescales.