Bailey Total Building Envelope CPD: Rainscreen Cladding

11
Specifying for Performance Importance of Correct Specification of Rainscreen Cladding Systems

description

Bailey CPD on rainscreen cladding looking at best practice in design and specification of the building envelope.

Transcript of Bailey Total Building Envelope CPD: Rainscreen Cladding

Page 1: Bailey Total Building Envelope CPD: Rainscreen Cladding

Specifying for Performance

Importance of Correct Specification of Rainscreen Cladding Systems

Page 2: Bailey Total Building Envelope CPD: Rainscreen Cladding

Our Product Portfolio

• Solar Roofs

• Bolt-on eaves

• Complete fascias, gutter and soffit assemblies

• Extruded feature channels

• External gutters & downpipes

• Rainscreen Cladding

• Coping/Capping

• Louvre's

• Flat Roof Membranes

& Accessories

• Green & brown roofs

• V-Plank Ceilings

Page 3: Bailey Total Building Envelope CPD: Rainscreen Cladding

Our Rainscreen Portfolio

• Platinum – Cassette System

• Prima – Recessed Tray System

• Synergy – Hook On System

• Zenith - ACM Bonded

• Summit - ACM Recessed Fixed

Page 4: Bailey Total Building Envelope CPD: Rainscreen Cladding

• Aluminum:

• Anodisied

• PPC (Chrome Free)

• Standard

• Super durable

• Metals

• Stainless steel

• Zinc

• Core 10

• Other

• Embossing

• Perforated

Finish Options

Page 5: Bailey Total Building Envelope CPD: Rainscreen Cladding

The History of Rainscreens

• Centuries old technology

• First modern rainscreens were timber, 1940’s, Scandinavia

• Alcoa Building, Pittsburgh, USA, 1952

• The term “rainscreen cladding” adopted 1970’

Page 6: Bailey Total Building Envelope CPD: Rainscreen Cladding

How do rainscreens work?

Insert SK01 and refer to accompanying notes

Page 7: Bailey Total Building Envelope CPD: Rainscreen Cladding

Pressure Equalised

Insert SK04And refer to accompanying notes

(Pressure moderated)

Page 8: Bailey Total Building Envelope CPD: Rainscreen Cladding

Pressure Equalised

• Cavities are compartmentalised

• Openings calculated to allow rapid ingress and egress of air

• Water ingress reduced by ‘equalisation’ of internal and external pressures (pressure moderated system)

• Drained above compartment levels

• Suited to tall areas of rainscreen.

• Design intensive

• High pressures generated at corners require that the centres of vertical compartments are reduced

Page 9: Bailey Total Building Envelope CPD: Rainscreen Cladding

Cavity barriers

• Fire and smoke spread in rainscreen cavities is particularly dangerous

• It may travel more rapidly in the cavity than on the outside face of the cladding

• It may remain undetected by building users or Firefighters.

• Cavity barriers will limit the spread of fire and smoke

Page 10: Bailey Total Building Envelope CPD: Rainscreen Cladding

Example – Structural framing systemInsulation within stud zone

*Dew point

VCL + Plasterboard

30mm insulation board

150mm quilt insulation

Cementitious board

Vapour control layers

Page 11: Bailey Total Building Envelope CPD: Rainscreen Cladding

Thank you