B60 PRODUCT GUIDE - The Renewable Energy Hub · 2020. 6. 2. · Voltage Optimisation overview...
Transcript of B60 PRODUCT GUIDE - The Renewable Energy Hub · 2020. 6. 2. · Voltage Optimisation overview...
B60 PRODUCT GUIDE
- B60 Domestic VO Unit (Retrofit)
- B60-PVM Domestic VO Unit (New build and new PV systems)
- ROM RCBOs
- RO2RCBOs
- RO2NE RCBO
- DEHN
WHY DO WE NEED TO OPTIMISE SUPPLIES?
WHAT SAVINGS CAN BE EXPECTED?
DID YOU KNOW?
Voltage Optimisation overview
Voltage Optimisation is a ‘foundation efficiency technology.’ That is to say it compliments or enhances the performance of renewable technologies allowing them to integrate more harmoniously and effectively into your projects.
It needs to be understood that a Voltage Optimiser does not directly make an energy saving – it merely creates a voltage that derives a saving by providing a voltage closer to the designed parameters of your appliances.
The result is an energy saving but it is the appliance that is consuming less power and not some power ‘electrickery’ going on at the optimiser end.
We each have around £10,000 of appliances in our homes. Many of our appliances operational lives could be shortened by as much as 55% as a consequence of over voltage.
The output from Solar Panels goes into the home or back into the grid at approximately 5V higher than the grid supply.
In terms of reduction in demand typically between 6 & 14% of billing.Voltage Optimisation does not itself save kWh. It creates a condition for savings to be achieved.
As an ISO9001 certifed supplier with the strictest quality assurance systems, we make extensive efforts to ensure that all our products meet or exceed the required quality standards.
A continuous development program ensures a high level of innovation in all our products.
In areas where there is a high proliferation of solar – voltages have been recorded in the UK as high as 270V!
The straight forward approach to this is anyone with a voltage that persists at 234V or higher which accounts for about 90% of homes in the UK. An electrician can check this for you or you can buy a simple plug in logger for less than £20.
WHO SHOULD OPTIMISE THEIR SUPPLY VOLTAGES?
- An increase in the power they consume
- Electrical bills and carbon footprint being unnecessarily raised
- The operating life of appliances being reduced dramatically
Because supplied grid voltages are higher than the appliances optimal voltage requirement. This results in:
CPN electrical circuit protection components and products are designed in the UK.
For connected PV systems the B60 if installed with the PV+ unit prevents over-voltage cutout during peak generation periods. By doing this, increases of up-to 25% in generation are achievable over the year.
The benefits of Voltage Optimisation
Reduces household demand by restricting voltage to a
voltage closer to the appliances optimal design parameter
Reduces electricity bills by up to 15%
Reduces carbon footprint
Extends the useful operating life of household appliances
Reduces landfill by preserving appliances
Enhances overall ROI on solar PV Systems and Air Sourced
Heat Pumps
It is non-invasive and requires no behavioural change to
display results
It can be installed in under 1 hour and doesn’t require
switching providers
In most cases it will pay back the end user within 5 years
Increases household safety as prolonged overvoltage can
cause appliances to overheat or even catch fire
Compliments renewable technology in providing on site
governance of supplied household voltages from inverters
back out to household load
Itisdesignedtobeconnectedinserieswiththe
meterforthedwelling,andtheconsumerunit.
protectionbuiltin.
Ratedat14kW,theunitissuitableforthemajorityofdomesticandlightcommercial/retailinstallations.
FEATURES
-ThemostcompactVOunitonthemarket
-5yearwarranty
-Capableofhandling14.5kWcontinuously (mostcompetitorunitsare9kWrated)
-Lowcostwithlowfootprint
-Extremelyefficient
-Reliableandnon-intrusive
-Builtbyelectriciansforelectricians
B60 Domestic Voltage Optimisation Unit
SPECIFICATION
Input (Volts) Nominal input voltage 235 – 253V, 50Hz, Single Phase AC
Output (Volts) Nominal input voltage less 18V
Max Load 14kW
Dimensions 310mm x 235mm x 100mm
Weight Approximately 10.0kgs
Operating Temperature -5°C to +40°C
Terminal Capacity Incoming Live = 35.0mm2 Outgoing Live = 35.0mm2 Incoming Neutral = 35.0mm2 Outgoing Neutral = 35.0mm2
MCB 63 Amp 6kA Type B to BS EN 60898
Enclosure Mild Steel Powder Coated
Ingress Protection IP20
Cable Entry Facility Bottom – 2 x 32mm
5 YEAR warranty
The single phase B60 Voltage Optimisation unit is designed for use in domestic and light commercial / retail applications.
unit, the B60 offers 18 volt subtractive performance.
18V(i.e.:a240Vsupplywouldbereducedto222V).unit.Theunitreducestheincomingsupplyvoltageby
Installed between the electricity meter and main consumer
incomingsupplyinstalledbetweenthemainelectricity
The B60 is a single phase Voltage Optimisation
The B60 has short circuit, overload and thermal
OptimisationunitdesignedtoworkwithPVinstallations.
Theunitreducestheincomingsupplyvoltageby18V(i.e.:a240Vsupplywouldbereducedto222V).Itisdesignedtobeconnectedinserieswiththeincomingsupplyinstalledbetweenthemainelectricitymeterforthedwelling,andtheconsumerunit.
overloadandthermalprotection.
Ratedat14kW,theunitissuitableforthemajorityofdomesticandlightcommercial/retailinstallations.
TheunithasadedicatedPVsupplyRCBOandaMIDmeter.
FEATURES
-TheB60PVMistheonlyunitcurrentlyinproduction thatiscapableofconnectingdirectlytoSolarPVwith abuilt-inFIT/MIDapprovedgenerationmeter
-Allthisreducesinstallationtimesignificantlyand removestheneedforaseparatemeteranda one-wayconsumerunit
-Itcomeswitha5YearWarrantyandwillreduce paybacksonSolarsystemstypicallyby18-24months andprotectsallofyourgadgetsfromtheeffectsof overvoltage
B60-PVM Domestic Voltage Optimisation Unit with PV connections & MID certified feed in tariff meter
SPECIFICATION
Input (Volts) Nominal input voltage 235 – 253V, 50Hz, Single Phase AC
Output (Volts) Nominal input voltage less 18v
Max Load 14kW
Dimensions 364mm x 235mm x 100mm
Weight Approximately 10.0 kgs
Operating Temperature -5°C to +40°C
Terminal Capacity Incoming Live = 35.0mm2 Outgoing Live = 35.0mm2 Incoming Neutral = 35.0mm2 Outgoing Neutral = 35.0mm2
MCB 63 Amp 6kA Type B to BS EN 60898
RCBO 16 Amp Type B to BS EN 61009
Enclosure Mild Steel Powder Coated
Ingress Protection IP20
Cable Entry Facility Bottom – 2 x 32mm, 1 x 20mm Diameter
Meter MID Certified
Optimisation unit is designed to work with PV installations and for use in domestic and light commercial / retail applications.
Installed between the electricity meter and
offers 18 volt subtractive performance.
The single phase B60-PVM Voltage
main consumer unit, the B60-PVM
The B60-PVM is a single phase
The B60-PVM is equipped with short circuit,
FEATURES
-SPMCBSizedRCBO
-6KABreakingCapacity
-Ratings6ampto32amp
-EarthLeakageRating30ma
-B&CCurveAvailable
-ConformstoBSEN1009
Ideal for domestic applications to give you circuit integrity without using an RCD that offers earth fault protection to other circuits.
The unique benefit is that it is MCB sized saving you a great deal of space inside the consumer unit, adapted busbar supplied.
Ideal for OEM applications including Caravan Park Hook Up pedestals that require Live and Neutral disconnection.
The unique benefit is that its MCB sized saving you a great deal of space.
ROM RCBO Residual Current Circuit Breaker with Over Current Protection
B Curve Part No. C Curve Part No.B Curve Description C Curve Description
1Pole6ABCurve30mA6KARCBO 1Pole6ACCurve30mA6KARCBO
1Pole10ABCurve30mA6KARCBO 1Pole10ACCurve30mA6KARCBO
1Pole16ABCurve30mA6KARCBO 1Pole16ACCurve30mA6KARCBO
1Pole20ABCurve30mA6KARCBO 1Pole20ACCurve30mA6KARCBO
1Pole25ABCurve30mA6KARCBO 1Pole25ACCurve30mA6KARCBO
1Pole32ABCurve30mA6KARCBO 1Pole32ACCurve30mA6KARCBO
ROM106B/030 ROM106C/030
ROM110B/030 ROM110C/030
ROM116B/030 ROM116C/030
ROM120B/030 ROM120C/030
ROM125B/030 ROM125C/030
ROM132B/030 ROM132C/030
RO2NE RCBO Residual Current Circuit Breaker with Over Current Protection
Smaller than a
standard RCBO
RO2 RCBO Residual Current Circuit Breaker with Over Current Protection
B Curve Part No. C Curve Part No.B Curve Description C Curve Description
2Pole6ABCurve30mARCBO 2Pole6ACCurve30mARCBO
2Pole10ABCurve30mARCBO 2Pole10ACCurve30mARCBO
2Pole16ABCurve30mARCBO 2Pole16ACCurve30mARCBO
2Pole20ABCurve30mARCBO 2Pole20ACCurve30mARCBO
2Pole25ABCurve30mARCBO 2Pole25ACCurve30mARCBO
2Pole32ABCurve30mARCBO
2Pole40ABCurve30mARCBO
2Pole32ACCurve30mARCBO
2Pole40ACCurve30mARCBO
RO206B/030 RO206C/030
RO210B/030 RO210C/030
RO216B/030 RO216C/030
RO220B/030 RO220C/030
RO225B/030 RO225C/030
RO232B/030
RO240B/030
RO232C/030
RO240C/030
Ideal for OEM applications including Caravan Park Hook Up pedestals that require Live and Neutral disconnection, standard 2 module width.
Part No. Description
2PoleNE6AC1ModuleRCBO
2PoleNE10AC1ModuleRCBO
2PoleNE16AC1ModuleRCBO
2PoleNE25AC1ModuleRCBO
2PoleNE32AC1ModuleRCBO
RO2NE206C/030
RO2NE210C/030
RO2NE216C/030
RO2NE225C/030
RO2NE232C/030
FEATURES
-SPMCBSizedRCBO
-6KABreakingCapacity
-Ratings6ampto32amp
-EarthLeakageRating30ma
-MidTripToggle
-CCurve
-L&NDisconnection
-ConformstoBSEN1009
FEATURES
-2PoleElectromagneticRCBO
-6KABreakingCapacity
-Ratings6ampto40amp
-EarthLeakageRating30ma
-B&CCurveAvailable
-L&NDisconnection
-ConformstoBSEN1009
DEHN 900450 / DEHN 900455
DEHN 900455 SPECIFICATION
SPD according to EN 61643-11 Type 2
Power Supply System Three-phase TT / TN system
Input (Volts) 230 / 400V (50 / 60Hz)
Dimensions 36mm x 85mm x 58mm
Maximum Mains-side Over Current Protection MCB C 63 A
Operating Temperature -40°C to +80°C
Operating State Green / Red
Number of Ports 1
Mounting 35mm DIN rails according to EN 60715
Enclosure Thermoplastic, grey, UL 94 V-0
Ingress Protection IP20
Capacity 2module(s), DIN 43880
Installation Indoors
DEHN 900450 SPECIFICATION
SPD according to EN 61643-11 Type 2
Power Supply System Single-phase TT / TN system
Input (Volts) 230 / 400V (50 / 60Hz)
Dimensions 18mm x 85mm x 58mm
Maximum Mains-side Over Current Protection MCB C 63 A
Operating Temperature -40°C to +80°C
Operating State Green / Red
Number of Ports 1
Mounting 35mm DIN rails according to EN 60715
Enclosure Thermoplastic, grey, UL 94 V-0
Ingress Protection IP20
Capacity 1 module(s), DIN 43880
Installation Indoors
These new type 2 surge devices meet all the requirements of BS7671 amendments in section 534. With a 5kA surge current rating and a lower than 1.5kV voltage protection level they will protect sensitive installed equipment.
These units are DIN mounted, show the status in the indicator window and are slimmer than before.
They are also fully coordinated with the type 1 and type 3 surge devices within the range.
Unit 15, Cridlake, Axminster, Devon EX13 5BT
0845 862 9910 / [email protected]