B2126 Series FG Piping
description
Transcript of B2126 Series FG Piping
![Page 1: B2126 Series FG Piping](https://reader037.fdocuments.in/reader037/viewer/2022102817/563db974550346aa9a9d7964/html5/thumbnails/1.jpg)
competitive materials comparison
featuring
RED THREAD® IIA Fiberglass Primary Pipe andSecondary Containment Pipe
for Underground Fuel Installations
Bulletin No. B2126June 15, 2002
RED THREAD® IIA PIPE
*
![Page 2: B2126 Series FG Piping](https://reader037.fdocuments.in/reader037/viewer/2022102817/563db974550346aa9a9d7964/html5/thumbnails/2.jpg)
11⁄2" Flexible Coaxial Pipe $4,5642" Flexible Coaxial Pipe $6,769
Double-wall Fiberglass Pipe $3,588Single-wall Fiberglass Pipe $1,437
Double-wall Fiberglass Pipe $7,465Single-wall Fiberglass Pipe $3,006
TraditionalFiberglass Pipe
Layout
SeriesFiberglass Pipe
Layout
Series FlexiblePipe Layout
TYPICAL STATION — MATERIALS COST COMPARISON OF ALL SYSTEMS
■ The use of flexible (rubber) entry fittings now makesseries layout piping a practical alternative for fiberglasspiping systems.
■ Single-wall RED THREAD IIA fiberglass piping still pro-vides the lowest material cost for a typical installationusing either the traditional or the series piping layout.
■ Double-wall RED THREAD IIA fiberglass piping is morethan 25 percent less material cost than 11⁄2" flexiblecoaxial piping in a series layout.
■ Single-wall RED THREAD IIA fiberglass pipe (where sin-gle-wall is permitted) and a good leak detector is thelowest priced system available.
T1 T2
Last field joint.
TANK
Dispensers
Tanks
Dispensers
Tanks
Dispensers
Tanks
T1 T2
FIRST DISPENSER SUMP CONNECTIONFOR SERIES FIBERGLASS PIPE
Last field joint.
Step
Step Step
![Page 3: B2126 Series FG Piping](https://reader037.fdocuments.in/reader037/viewer/2022102817/563db974550346aa9a9d7964/html5/thumbnails/3.jpg)
4"
DISPENSER SUMP DETAIL FOR SERIES FIBERGLASS PIPE
INSTALLATION SEQUENCE FOR SERIES FIBERGLASS PIPE
Step 1■ Start installation from tank.
■ Make up tee assemblies, including flex connectors.Fiberglass or steel tees can be used, but fiberglass leavesmore room (see diagram above).
■ Insert primary pipe inside containment. Push pipeinto downstream dispenser sump with sump entry fit-ting disassembled and tee pushed out of the way.
■ Position pipe for bonding last field coupling or fitting,and assemble first sump entry fitting.
■ Bond last field joint and then first tee joint (T1).
■ Insert next length of primary pipe inside secondarypipe; push into next downstream dispenser sump asbefore.
Step 2■ Bond upstream tee joint (T2) then first tee joint in
sump (T3).
Step 3■ Bond tee joint T4, then the 90˚ connection.
ContainmentPipe
Primary Pipe
2 x 1 1⁄2" ThreadedReducer Bushing
Fiberglass Tee
6 3⁄4"
10 1⁄2"
Steel Tee
2" BxM ThreadedAdapter
■ Use a fiberglass tee instead of asteel tee for more room inside thedispenser sump.
T3 T4
FiberglassDispenser Sump
Fiberglass Tee
Flex Connector
Flexible SumpEntry Fitting
2 x 1 1⁄2" ThreadedReducer Bushing
Step
Test/Drain Valve
![Page 4: B2126 Series FG Piping](https://reader037.fdocuments.in/reader037/viewer/2022102817/563db974550346aa9a9d7964/html5/thumbnails/4.jpg)
BENEFITS COMPARISON OF FIBERGLASS vs. FLEXIBLE PRODUCTS
■ Excellent flow characteristics: Smooth I.D.RED THREAD IIA pipe offers less head loss and greaterflow than some flexible products with convoluted I.D.’s.
Fiberglass fittings create minimal reductions in I.D.,unlike some flexible fittings.
■ Excellent flow characteristics: Larger I.D.Two-inch RED THREAD IIA fiberglass pipe has a nominal2.235" I.D., and 3-inch RED THREAD IIA fiberglass pipehas a nominal 3.360" I.D.—much larger than 11⁄2" and 2"flexible systems.
■ 30+ years of reliable service usingfiberglass and a 30-YEAR WARRANTY*Smith Fibercast has proven itself in thepetroleum marketing industry with reliable UL Listed fiberglass piping systems for more than 30 years.
■ RED THREAD IIA fiberglass pipe is not affected by microbial attack
■ Reliability of sloping of product, vent, and vapor pipingRED THREAD IIA fiberglass pipe holds grade and willdrain fluid to the detection point.
RED THREAD IIA fiberglass pipe is used by virtually alloil companies for vapor return lines due to the concernfor trapped fluid in vapor return lines.
■ RED THREAD IIA fiberglass pipe has a large safety factor
RED THREAD IIA fiberglass pipe has a burst pressuregreater than 2,000 psi—more than three times the burstpressure of most flexible hoses.
Flow ■ Known Service Life ■ Pressure Capability:
UL-Listed RED THREAD IIA fiberglass pipefrom Smith Fibercast
offers the extra safety factor in
® Registered Trademark of Varco International, Inc.©Copyright 1998-2002 Varco International, Inc.
PRINTED IN U.S.A., 5M602
2700 West 65th Street • Little Rock, Arkansas 72209-8592Telephone (501) 568-4010 • FAX (501) 568-4465
URL: http://www.smithfibercast.com
It is the policy of Smith Fibercast to improve its products continually. In accordance with that policy, theright is reserved to make changes in specifications, descriptions, and illustrative material contained inthis manual as conditions warrant. The information contained herein is general in nature and is notintended to express any warranty of any type whatsoever nor shall any be implied.
The information contained herein is drawn fromsources deemed to be representative and reliable. It isintended for general information purposes only. Costsof installation under actual conditions may differ.
* Limited warranty. Please review Smith Fibercast’s written warranty for terms and conditions.