B S Mixing at Tevatron

42
B S Mixing at Tevatron Donatella Lucchesi University and INFN of Padova On behalf of the CDF&D0 Collaborations First Workshop on Theory, Phenomenology an Experiments in Heavy flavour physics May 29-31 2006, Capri, Italy

description

B S Mixing at Tevatron. Donatella Lucchesi University and INFN of Padova On behalf of the CDF&D0 Collaborations. First Workshop on Theory, Phenomenology and Experiments in Heavy flavour physics May 29-31 2006, Capri, Italy . x 2 = 1.21 + 0.02 +0.035. -0.014. - PowerPoint PPT Presentation

Transcript of B S Mixing at Tevatron

Page 1: B S  Mixing at Tevatron

BS Mixing at TevatronDonatella Lucchesi

University and INFN of Padova On behalf of the CDF&D0 Collaborations

First Workshop on Theory, Phenomenology andExperiments in Heavy flavour physics

May 29-31 2006, Capri, Italy

Page 2: B S  Mixing at Tevatron

Donatella Lucchesi 2May 31, 2006

Bs Mixing in The Standard Model12 12

* *12 122M M iHM M

, 12 1222Im( ) iH L M, 12 122Re( ) iH LM M M

/ 2

/ 2

m

12

1( )L H

L H

)()(

2)()(

tBtBiM

tBtB

dtdi

In the ratio uncertainties cancels:

2

22

2

2

2

2

td

ts

Bd

Bs

td

ts

BdBd

BsBs

Bd

Bs

d

s

V

Vmm

V

VBfBf

mm

mm

= 1.21+0.02+0.035-0.014

(M. Okamoto, hep-lat/0510113)

Big uncertainties

Page 3: B S  Mixing at Tevatron

Donatella Lucchesi 3May 31, 2006

Measurement Principle in a Perfect World

))cos(1(21)(

0)(

0tmetP q

t

BB qq

)cos( tmNNNNA smixnomix

mixnomix

Bs vs. Bd oscillation

B lifetime

Rather than fit for frequencyperform a ‘Fourier transform’

ms [ps-

1]

A

Page 4: B S  Mixing at Tevatron

Donatella Lucchesi 4May 31, 2006

Road Map to ms Measurement

1. Final state

reconstruction

2. High resolution on proper decay length

T

pL

T

Bct p

ctpm T

xy

3. Tag B flavor at

production time

Opposite Sidefragmentationparticle: , K…

,K

Page 5: B S  Mixing at Tevatron

Donatella Lucchesi 5May 31, 2006

Adding all the realistic effects

Proper time resolution

T

pL

T

Bct p

ctpm

T

xy

Flavor tagging power

Page 6: B S  Mixing at Tevatron

Donatella Lucchesi 6May 31, 2006

Road Map to ms Measurement

1. Final state

reconstruction

2. High resolution on proper decay length

T

pL

T

Bct p

ctpm T

xy

3. Tag B flavor at

production time

Opposite Sidefragmentationparticle: , K…

,K

measure efficiency and dilution D: D2 gives the “effective” number of events

Page 7: B S  Mixing at Tevatron

Donatella Lucchesi 7May 31, 2006

Primary Vertex

Secondary Vertex

d = impact parameter

B

Decay

Le

ngthL

~ 48 mincludes 33 m ofbeam spot

Triggers UsedCDF:Two tracks displaced from PV

D0: Single inclusive muons

o Pt>3,4,5 GeV Dimuons:

o Other muon for flavor tagging

Page 8: B S  Mixing at Tevatron

Donatella Lucchesi 8May 31, 2006

Bs Data sample

BsDs Ds KK Ds K*0K K*0 K Ds 3BsDs3 Ds Ds K*0K

Signal BsDs Ds

Partially reconstructed B mesons

Combinatorial backgroundB0 D-

Page 9: B S  Mixing at Tevatron

Donatella Lucchesi 9May 31, 2006

CDF Hadronic Bs yields summaryDecay channel YieldBsDs Ds 1570±4

3BsDs Ds K*0K 857±32BsDs Ds 3 612±37BsDs3 Ds 493±37BsDs3 Ds K*0K 204±26Total 3736±7

9B+ D0 ~ 26,000 B0 D- ~ 22,000

Page 10: B S  Mixing at Tevatron

Donatella Lucchesi 10May 31, 2006

CDF Semileptonic samples

BsDsX Ds KK Ds K*0K K*0 K Ds 3

Ds~ 53,000

Page 11: B S  Mixing at Tevatron

Donatella Lucchesi 11May 31, 2006

Decay channel:Bs+Ds

-XDs

-- and K+K-

Cuts selected maximizeBSS /

NBs = 26,710 ± 556(stat)

+D- +Ds-

D0 Semileptonic samples

Page 12: B S  Mixing at Tevatron

Donatella Lucchesi 12May 31, 2006

Road Map to ms Measurement

1. Final state

reconstruction

2. High resolution on proper decay length

T

pL

T

Bct p

ctpm T

xy

3. Tag B flavor at

production time

Opposite Sidefragmentationparticle: , K…

,K

Page 13: B S  Mixing at Tevatron

Donatella Lucchesi 13May 31, 2006

Proper decay time reconstruction

Semileptonic decay ct = LxylDMB/Pt

lDK Fully reconstructed events ct = Lxy

BMB/PtB

CDFK=Pt

lD/PtBLxy

B/LxylD

It is needed to: Measure the lifetime to establish the time scale Determine the time resolution

D0K=Pt

lD/PtB

Page 14: B S  Mixing at Tevatron

Donatella Lucchesi 14May 31, 2006

B Lifetime measurement

c(Bs)=1.538±0.040(stat) psCentral value c(Bs)=404-416 mStatistical error ~10 m

Page 15: B S  Mixing at Tevatron

Donatella Lucchesi 15May 31, 2006

Proper time resolution, t Lifetime measurement not very sensitive In the ms fit each event weighted by its resolution Dedicated calibration needed

Prompt Charm + track sample J/+- sample

Page 16: B S  Mixing at Tevatron

Donatella Lucchesi 16May 31, 2006

Proper time resolution, t

Page 17: B S  Mixing at Tevatron

Donatella Lucchesi 17May 31, 2006

Road Map to ms Measurement

1. Final state

reconstruction

2. High resolution on proper decay length

T

pL

T

Bct p

ctpm T

xy

3. Tag B flavor at

production time

Opposite Sidefragmentationparticle: , K…

,K

measure efficiency , dilution D

D2 gives the “effective” number of events

Nright-NwrongNright+NwrongD= = 2right-1

Page 18: B S  Mixing at Tevatron

Donatella Lucchesi 18May 31, 2006

+D- +Ds-

N = 5601 ± 102 (stat) -lepton (electron or muon)

- Secondary Vertex - Event Charge

Tags combined

Opposite Side Taggers Use data to calibrate the taggers and to evaluate D Fit semileptonic and hadronic Bd sample to measure: D, md

D2 =2.480.21(stat.) (syst.)% +0.08-0.06

Page 19: B S  Mixing at Tevatron

Donatella Lucchesi 19May 31, 2006

Same Side Tagger

B0s likely to have K

B0/B± likely to have nearby

Use PID to separate pion from kaonTune Monte Carlo to reproduceB0,B- distributions then apply to Bs

Page 20: B S  Mixing at Tevatron

Donatella Lucchesi 20May 31, 2006

Flavor Taggers performances

Exclusive combination of tags in OST SSTK-OST combination assumes independent tagging information

Page 21: B S  Mixing at Tevatron

Donatella Lucchesi 21May 31, 2006

Amplitude Scan notation A is introduced: ))cos(A1(

21)(

0)(

0tmetP q

t

BB qq

A=1 when ms

measured = mstrue

B0 mixing in hadronic decayIn the figure: Points: A±(A) from Likelihood fit for different m Yellow band: A±1.645(A) Dashed line: 1.645(A) vs. m m excluded at 95% C.L. if A±1.645(A)<1 Measured sensitivity: 1.645(A)=1

Page 22: B S  Mixing at Tevatron

Donatella Lucchesi 22May 31, 2006

D0 Results

“favored value’’ = 19 ps-1 17<ms<21 ps-1 at the 90% C.L.

m19 ps-1 :A/A=2.5 and A-1/A=1.6

Sensitivity = 14.1ps-1

ms>14.8 at the 95% C.L.

Page 23: B S  Mixing at Tevatron

Donatella Lucchesi 23May 31, 2006

Choice of Procedure Before un-blinding: p-value probability that observed effect is due background fluctuation. No search window.

p-value<1%?

make double sided confidence interval from (ln()), measure ms

set 95% C.L. basedon Amplitude Scan

yes noln[(A=1)/ln(A=0)]

Probability of random tag fluctuation estimated on data (randomized tags) and checked with toy Monte Carlo

Page 24: B S  Mixing at Tevatron

Donatella Lucchesi 24May 31, 2006

CDF Amplitude Scans

Sensitivity: 17.3 ps-1

ms> 15.9 ps-1 @ 95% CL Sensitivity: 25 ps-1

ms> 16.7 ps-1 @ 95% CL

Page 25: B S  Mixing at Tevatron

Donatella Lucchesi 25May 31, 2006

CDF Combined Amplitude Scan

Sensitivity betterthan the W.A.20.1 ps-1

Rare case!!

Page 26: B S  Mixing at Tevatron

Donatella Lucchesi 26May 31, 2006

Likelihood Profile & significance

How often random tags produce a likelihood deep this dip?

Probability of fake: p-value=0.5% Measure ms !!!

Page 27: B S  Mixing at Tevatron

Donatella Lucchesi 27May 31, 2006

Measurement of ms

ms =17.33+0.42 ± 0.07 ps-1

-0.21

17.00 < ms <17.91 ps-1 at 90% C.L.16.94 < ms <17.97 ps-1 at 95% C.L.

Page 28: B S  Mixing at Tevatron

Donatella Lucchesi 28May 31, 2006

|Vtd|/|Vts| Determination

Used as inputs: mBs/mBd = 0.9830 PDG 2006 2 = 1.210+0.47 (M. Okamoto, hep-lat/0510113) md = 0.507±0.005 PDG 2006-0.35

|Vtd|/|Vts|=0.208 +0.008 (stat.+syst.)-0.007

|Vtd|/|Vts| = 0.199 +0.026 (stat) +0.018 (syst)-0.025 -0.015

Latest Belle result bs (hep-ex/050679):

Page 29: B S  Mixing at Tevatron

Donatella Lucchesi 29May 31, 2006

Conclusions 1 fb-1 of data used for Bs oscillation study

D0: 2.5 deviation from 0 in the Amplitude Scan at ms=19 ps-1

90% C.L. interval for ms: 17-21 ps-1

o For the summer: • Include DsK*K, DsKsK Ds3 and e+Ds• Include hadronic decays• Include Same Side Tagging

Page 30: B S  Mixing at Tevatron

Donatella Lucchesi 30May 31, 2006

Conclusions cont’d CDF: experimental signature for Bs-Bs oscillations Probability of random fluctuation is 0.5% First direct measurement of:

ms =17.33+0.42 ± 0.07 ps-1

-0.21

|Vtd|/|Vts|=0.208 +0.008 (stat.+syst.)-0.007

o Future:• Include other decays (Partially recon. Ds

*Ds/)• Combine efficiently flavor tags• Improve ct resolution

Page 31: B S  Mixing at Tevatron

Donatella Lucchesi 31May 31, 2006

BACKUP

Page 32: B S  Mixing at Tevatron

Donatella Lucchesi 32May 31, 2006

The Accelerator

Page 33: B S  Mixing at Tevatron

Donatella Lucchesi 33May 31, 2006

Detector for the measurement: CDFTrigger: displaced tracks(SVT)

Tagging Power:TOF & dE/dX (COT)

Proper time Resolution:SVX and L00

Page 34: B S  Mixing at Tevatron

Donatella Lucchesi 34May 31, 2006

Detector for the measurement: D0Fiber and Silicon trackers in 2T Solenoid field

Fine segmentationLiquid Ar Calorimeter& Preshower

Three layerssystem & absorber

Hermetic detector

Page 35: B S  Mixing at Tevatron

Donatella Lucchesi 35May 31, 2006

Tevatron Luminosity

1fb-1

Used in theanalysis

Page 36: B S  Mixing at Tevatron

Donatella Lucchesi 36May 31, 2006

Parametrizing tag decision

Page 37: B S  Mixing at Tevatron

Donatella Lucchesi 37May 31, 2006

Calibrating SSTK

Page 38: B S  Mixing at Tevatron

Donatella Lucchesi 38May 31, 2006

Calibrating SSTK

Tune MC to reproduce B0/± dilution and then measure itfor SSTK

Page 39: B S  Mixing at Tevatron

Donatella Lucchesi 39May 31, 2006

D0 Procedure

Correction factor due to missing neutrino

Several effects taken into account: Resolution scale factor for detector mismodeling Reconstruction efficiency as function of decay length Physical and combinatorial background contributions

Page 40: B S  Mixing at Tevatron

Donatella Lucchesi 40May 31, 2006

Systematic Uncertainties Amplitude Scan

Related to absolute value of A important when setting a limitCancel out in A/AVery small compared to statistical error

Page 41: B S  Mixing at Tevatron

Donatella Lucchesi 41May 31, 2006

Combined Amplitude Scan: an other view

Page 42: B S  Mixing at Tevatron

Donatella Lucchesi 42May 31, 2006

Systematic Uncertainties on ms

Fit Model: negligible

Relevant only lifetime scale