B-K LIGHTINGPRELIMINARY 7-13-16 REFERENCE40429 Brickyard Drive • Madera, CA 93636 • USA NUMBER...
Transcript of B-K LIGHTINGPRELIMINARY 7-13-16 REFERENCE40429 Brickyard Drive • Madera, CA 93636 • USA NUMBER...
PRELIMINARY
7-13-16REFERENCE NUMBER
INS00093840429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900 www.bklighting.com • [email protected] LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
SS™ / SSL™/ VS™/ VSL™Round Back Box Installation Instructions
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
This set of instructions works for:SS - Step Star™ (A or B)SSL - Step Star Louver™
VS - Versa Star™VSL - Versa Star Louver™
SS-A or B
SSL VS VSL
TOOLSNEEDED:
By Others
1/8” Allen Wrench
Phillips Screwdriver
Waterproof Wire Connectors
Junction Box
Universal Ring
TECHNOLOGYwith TECHNOLOGY
• Product must be installed by a qualified person in a mannerconsistent with its intended use and in compliance with theNational Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes.
• Followproductlabelinformationandinstructions.
• QualifiedPersonnelmustperformallservicingor relampingofthis product.
• Beforewiringtopowersupplyandduringservicingorrelamping,turnoffpoweratfuseorcircuitbreakerbeforeservice.
• The use of accessory equipment not recommended by themanufacturerorinstalledcontrarytoinstructionsmaycauseanunsafecondition.Theuseofdamagedcomponentsmaycauseanunsafeconditionandvoidproductwarranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
• Donotblocklightemanatingfromproductinwholeorpart,asthismaycauseanunsafecondition.
• Never operate the fixture with missing or damaged lens. Lensmustbecleanedonregularbasis.
• Entire fixturemaybecomeextremelyhot.Donot touchhotlensorfixturebody.Donottouchthelampatanytime.Useaclean,dry,softclothtohandlethelamp.Oilfromskinmaydamagethelampandcauseittorupture.
• Replace lamp only with correct wattage and type of lampmarkedonfixturelabel.
• All gaskets, o-rings and sealing surfacesmust be kept cleanduringinstallationandservice;failuretodothismaycauseanunsafeconditionandvoidproductwarranty.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS IMPORTANT SAFETY
INSTRUCTIONSLightedlampisHOT!
WARNING-ToreducetheriskofFIREORINJURYTOPERSONS: Turnoff/unplugandallowtocoolbeforereplacinglamp. LampgetsHOTquickly!Contactonlyswitch/plugwhen
turning on. Donottouchhotlens,guard,orenclosure(seediagram/
picture). Keeplampawayfrommaterialsthatmayburn.
Donotouchthelampatanytime.Useasoftcloth.Oilfromskinmaydamagelamp.
Donotoperatetheluminairefittingwithamissingordamagedshield.
SAVE THESE INSTRUCTIONS
·Suitableforwetlocation·Additionallysuitableformountingwithin4ft.oftheground•TypeNon-ICIMPORTANT LISTINGS AND CERTIFICATIONS
Hot SurfaceWarning Low Voltage
Pleaserefertothelowvoltagedesignguideatwww.bklighting.com/lvguidebeforeinstallationforproperwireselection.
Driver
AdjustableBracket
Faceplate
SS
40429 Brickyard Drive • Madera, CA 93636 • USA559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected] LIGHTING
PROJECT:
TYPE:
4. Mount faceplate using two (2) #10-24 screws with 1/8”Allenwrench.Tightentocompressgasket.Donot over tighten.
3. To aim adjustable bracket loosen the two (2)Phillip screws attaching the adjustable brackettothefaceplate.Aimtodesiredposition.Tightentwo (2) Phillip screws to lock in place whendesired angle is set.
Phase 2 - Finish Installation of Fixture with Remote Transformer
1. Remove #10-24 Phillips screws from mountedbackbox.Installuniversalmountingring(suppliedwithfaceplate)using#10-24screwsontobackbox.Alignfaceplatemountingholestofinalmountingposition.
2. Make watertight connections from remotetransformer to fixture leadsusingwaterproofwire connectors (By Others). See wiring diagram.
Phase 1 - Rough InInstallationofBackbox
1. Install Conduit (By Others) to be used withthis product.
2. Installjunctionboxsothatfrontfaceisflushwith finished wall or ceiling.
3. Connect box to conduit and pull wires forconnections(SeeWiringdiagram).
Additional Info
• PleasefollowNationalandLocalelectricalcodesforyourarea.• 4”roundcastboxisprovidedwithFive(5)1/2”threadedhubs
forconduitentry(4onsidesandoneonbackofbox).• Suitableforthroughwire.• Suitableforinstallationintocombustiblematerials.• Ratedfor90°C.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSEREAD, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
SS™ / SSL™/ VS™/ VSL™Round Back Box Installation Instructions
PRELIMINARY
7-13-16REFERENCE NUMBER
INS000938
TECHNOLOGYwith TECHNOLOGY
LINE 12V
Fixture
COM
RemoteTransformer
COM
WIRING DIAGRAM
LED - For use with 12VAC remote transformer or magnetic transformers only. B-K Lighting cannot guarantee performance with third partymanufacturers’ transformers.
40429 Brickyard Drive • Madera, CA 93636 • USA559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected] LIGHTING
PROJECT:
TYPE:
IMPORTANT SAFETY INFORMATION LISTED ON REVERSEREAD, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
SS™ / SSL™/ VS™/ VSL™Round Back Box Installation Instructions
PRELIMINARY
7-13-16REFERENCE NUMBER
INS000938
TECHNOLOGYwith TECHNOLOGY
3. Mount faceplate using two (2) #10-24 screws with 1/8” Allen wrench. Tighten to compressgasket.Donotovertighten.
3. Mount faceplate using two (2) #10-24 screws with 1/8” Allen wrench. Tighten to compressgasket.Donotovertighten.
This product is available with Adjust-e-Lume™ (Patent Pend.) for Dynamic Lumen Output ControlWarning!Thelightoutputofthisproductmaybedynamicallyadjustedasdesiredtoraiseandlowerlightlevels.Pleaseensurethefixtureissettotheappropriatelightleveldesiredduringinstallation.
1. Use 1/8” Allen wrench to loosen #10-24 stainlessfaceplatescrewstoremovefaceplate.
3. Replace faceplate.2. With flat head screw driver rotate dial to desiredlumenoutput.
REPLACING OPTICS
1. Remove faceplate by loosening #10-24screws using 1/8” Allen wrench. Use Phillips screwdrivertoloosenheatsinkfromadjustablebracket.
2. Space three fingers evenly around the opticand gently rock optic to remove. Insert newoptic.
2. Disengage driver assembly by using quickdisconnects.Replacedriverassemblybyusingquickdisconnects,thenplacedriverbackintojunctionbox.
TO CHANGE LUMEN OUTPUT (IF REQUIRED)
REPLACING DRIVER
1. Use 1/8” Allen wrench to loosen #10-24 stainlessfaceplatescrewstoremovefaceplate.