AutoPIPE_v9.5_SS4c-highres

73
© 2011 Bentley Systems, Incorporated Mark Upston Director Structural Solutions & PipeStress AutoPIPE V8i SELECTseries 4 (v9.5)

Transcript of AutoPIPE_v9.5_SS4c-highres

Page 1: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Mark UpstonDirector Structural Solutions & PipeStress

AutoPIPE V8i SELECTseries 4 (v9.5)

Page 2: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

2 | WWW.BENTLEY.COM

Summary… • New AutoPIPE V8i SELECTseries4 (v9.5.0.x)

• Release date, November 2012

Page 3: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

3 | WWW.BENTLEY.COM

Equipment CheckPumps, Turbines,

Compressors

Iso’s Marked-UpStressISO

Drawings/ Reports3D

Model

Third Party Programs

MicroprotolVessel Design

Transient Flow

Analysis

FEAPlantFLOWFluid Flow Analysis

PULSPulsation Analysis

AutoPIPE NozzleNozzle/Vessel Limits

AutoPIPEPipe Stress Analysis

STAADStructural Analysis

AutoPLANT, PlantSpace, SP3D, PDS, PDMS

3D Modeling

NavigatorHot Clash Detection

3D Model

PlantWiseConceptual 3D

Design

PIDFEED

ProjectWiseProject

Management

DigitalPlant – Pipe Stress Analysis WorkFlow PIDFEED

ASME Flange Design

Pipe Support Vendor

Page 4: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

4 | WWW.BENTLEY.COM

AutoPIPE V8i SS4 (v9.5) EnhancementsMore than 70 new features

Page 5: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

5 | WWW.BENTLEY.COM

Piping Codes: FRP piping code ISO 14692

Nuclear JSME 2008

AutoPIPE v9.5 Major HighlightsNew Advanced Buried

Piping Design - Traffic & Seismic loads

Productivity ImprovementsFlange Design

InteroperabilityImproved DGN i-model Export,

PCF/PXF import & Caesar Import

Enhanced Color Graphics Pipe Properties /Segment

Page 6: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Design Codes

Page 7: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

7 | WWW.BENTLEY.COM

Piping Code : New JSME 2008 code• JSME 2008 Design code and JEAC material library• Re-certification of Japan’s nuclear power plants

Page 8: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

8 | WWW.BENTLEY.COM

• Seismic Levels “A” & “As” combined in new “S” level

Significant Changes in the JSME 2008 Edition

All SAM Levels Supported

New Service levels S, B, C, None.

Dynamic Seismic Cases

Page 9: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

9 | WWW.BENTLEY.COM

JSME Reports & Load CombinationsCode Compliance Load CasesAnalysis Summary

Page 10: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

10 | WWW.BENTLEY.COM

• New ISO 14692 FRP Piping Code (2005 Addenda)

Piping Codes : New ISO 14692 FRP Code

New FRP Libraries

Page 11: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

11 | WWW.BENTLEY.COM

FRP Pipe Properties

Poisson Ratio and A3 Factor for Cyclic Service

Long Term Hoop and Axial Allowable Envelope

Stresses

Pipe ID

Page 12: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

12 | WWW.BENTLEY.COM

FRP Bend Component

Biaxial Type and Ratio

Qualified Stress from Manufacturer

Smooth / Miter

Qualified Component

Page 13: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

13 | WWW.BENTLEY.COM

FRP Material Library

• ISO 14692• FIBERBOND• AMERON• FIBERCAST• SARPLAST• CONLEY• WAVISTRONG• HARVEL• REINFORCED PLASTIC

SYSTEMS

Page 14: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

14 | WWW.BENTLEY.COM

• Component Failure Stress Envelopes Supported

Piping Code : ISO 14692

Component Fully Measured

Simplified Rectangular

Plain Pipe Axial & Hoop 1:1 Stress

Ratio’s > 0.1

Axial & Hoop 1:1 Stress

Ratio’s <=0.1

Biaxial ratio R => 1

Bend NA Biaxial ratio R < 1

Biaxial ratio R => 1

Tee NA Biaxial ratio R < 1

Biaxial ratio R => 1

RectangularSimplifiedFully Measured

Code Compliance

Page 15: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Analysis

Page 16: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

16 | WWW.BENTLEY.COM

• Based on exact solution of linear dynamic equations of motion• Improved accuracy as problems due to period elongation or

numerical damping are avoided

Wilson-Ө is the only available method in CAESAR II unconditionally stable for Ө >1.37. However, this does not mean solution is accurate.

New PieceWise Exact Time History Method

Page 17: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

17 | WWW.BENTLEY.COM

New PieceWise Exact Time History Method

Page 18: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

18 | WWW.BENTLEY.COM

New Time History & Response Spectrum Dialogs

Page 19: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

19 | WWW.BENTLEY.COM

Time History Profile o New Option : Imposed

Displacement

Time History Location

XBD7 4

0.000000 .00.020000 2.0.030000 2.0.050000 .20.060000 -.70.061000 .00.120000 .0

New Displacement Time History

Page 20: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

20 | WWW.BENTLEY.COM

Solution for Piping Vibration Type of Vibration AutoPIPE Solution

1. Mechanical

A. Machinery Unbalanced Forces and Moments

B. Structure Borne Vibrations

Harmonic Displacement Analysis

2. Pulsation

Flow induced vibrations due to compressors & pumps

Harmonic Force Analysis

3. Pressure Surge, Hydraulic Hammer

Force Time History

Page 21: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

21 | WWW.BENTLEY.COM

New Improved Dialog for defining Harmonic Load

Page 22: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

22 | WWW.BENTLEY.COM

Visualize Individual Frequency Plots or Harmonic Superposition

Page 23: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

23 | WWW.BENTLEY.COM

Model Transient Vibration Effects by Applying Time History Loads

Page 24: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

24 | WWW.BENTLEY.COM

• Buoyancy will now be applied to segments• NTL import/export• Enabled by default

Limit Buoyancy to Selected Segments

Page 25: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

25 | WWW.BENTLEY.COM

• Soil weight on top of pipe (includingeffect of water table)

• Surface live loads (Highway, Railway,Airport, and user defined)

• Effect of seismic wave propagationalong pipeline (calculated as anequivalent temperature rise)

• Imposed displacement of support dueto building settlement

New Advanced Buried Pipeline Design

Page 26: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

26 | WWW.BENTLEY.COM

NewSoil Stress Categories

• Circumferential wall bending stress (Adams et. Al., ANSI AWWAC150, and ASCE 2001 w/2005 addenda)

• Ring buckling category• Seismic + Thermal category (Seismic includes SAM and wave

propagation effects)• Building settlement category

Soil Analysis Stress Categories

Page 27: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Post Processing

Page 28: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

28 | WWW.BENTLEY.COM

BS7159 User Hoop and Long Allowables

Code ReportCode Combinations

Page 29: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

29 | WWW.BENTLEY.COM

1000 Code and Non-Code Combinations

Code Combinations Non-Code Combinations

Page 30: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

30 | WWW.BENTLEY.COM

Modal Frequency Shown on Plot

Page 31: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

31 | WWW.BENTLEY.COM

Deflected Plot & Results Updated

Scrolling through the Combinations using VCR Buttons updates both

Deflected Plot and Results

Page 32: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Performance

Page 33: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

33 | WWW.BENTLEY.COM

Segment Grid Optimization (up to 50 times)Option Method 9.4.0.19

latest v9.5 build

Ctrl+Enter Check 48* sec 1 secUncheck 48* sec 1 sec

Line Number Drag Check 50* sec 6 secUncheck 50* sec 6 sec

Copy Down Check 51* sec 2 secUncheck 50* sec 1 sec

Model: BLNE2.DAT with 221 segments.

Page 34: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Modeling

Page 35: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

35 | WWW.BENTLEY.COM

Component Placement using Cylindrical Coordinates

• Insert / Modify Run dialog

• Insert / Modify Bend dialog

• Insert / Modify Valve dialog

• Insert / Modify FlexJoint dialog

• Insert / Modify Reducer dialog

• Insert / Modify Tee Point dialog

In AutoPIPE following symbolrepresent the following. Thetar radiusz Elevation

Page 36: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

36 | WWW.BENTLEY.COM

Fluid Density Factor • Fluid density can change by temperature and pressure conditions including phase e.g. Steam• Change Fluid density for Static, and Dynamic load cases.

Page 37: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

37 | WWW.BENTLEY.COM

New Pipe Identifier Tag e.g. 6” Bypass Line

Page 38: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

38 | WWW.BENTLEY.COM

Pressure Temperature Input GridNew Pressure / Temperature Grid menu options :

• Show Pressure Only• Show Temperature Only• Show Pressure and Temperature Only• Show All

Demo

Page 39: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

39 | WWW.BENTLEY.COM

Plot Reference Point Tag

Page 40: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

40 | WWW.BENTLEY.COM

• Go to Point Dialog

• Go to Origin

• Origin Symbol and text

• ViewSettings Show Origin checkbox on the Plot

Where is the Origin? - New “Goto Origin”

Page 41: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

41 | WWW.BENTLEY.COM

Improved Graphical Show Options

• Color Plots of Model Data• Pipe Properties • Toggle Property, Component

and Xtra Data On/OFF while Still Editing the Model

Page 42: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

42 | WWW.BENTLEY.COM

New Color Plot of All Visible SegmentsHint: Continue to model while viewing color plot of segments

Page 43: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

43 | WWW.BENTLEY.COM

New Color Plot of Pipe PropertiesHint: Edit the Model while viewing color plot of segments

Pipe Thickness

New Floating Legend

Page 44: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

44 | WWW.BENTLEY.COM

New Color Plot of Pipe Properties

Insulation Thickness

Page 45: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

45 | WWW.BENTLEY.COM

Isolate and Show Connected Segments

Page 46: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Reports

Page 47: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

47 | WWW.BENTLEY.COM

New Segment data report

Page 48: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

48 | WWW.BENTLEY.COM

New Equipment Summary Report

All the Load Combinations which have the highest FAIL Equipment Ratios are identified

Page 49: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Productivity Enhancements for new Flange Analysis & Design Module

Page 50: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

50 | WWW.BENTLEY.COM

Flange Analysis & Design Module• Flange Checks to ASME VIII Div 1 & 2 : 2010, ASME III

Appendix XI and ASME III NC 3658.1 (b) (ANSI check)• Material to ASME II, B31.1 or B31.3

Page 51: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

51 | WWW.BENTLEY.COM

• Flange Material Library Based on Flange Design Code

Default Flange Library

Page 52: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

52 | WWW.BENTLEY.COM

• Modify Flange from Flange Analysis• Flange Select synchronized with Plot

Flange Synchronization

Page 53: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

53 | WWW.BENTLEY.COM

• Restore Sort Order [More Options]

Flange Sort

Page 54: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

54 | WWW.BENTLEY.COM

• Hide Incomplete Flanges

Color Coded Incomplete Flange Data

Page 55: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

55 | WWW.BENTLEY.COM

ANSI Check - User Defined Pmax Pressure

Page 56: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

56 | WWW.BENTLEY.COM

Analysis Bolt Spacing Correction• Lethal Service

Page 57: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

57 | WWW.BENTLEY.COM

New Batch Processing switches• New Flag /n to perform automated flange analysis

• New Flag /l to Create the model input listing (*.RPT)

e.g. AUTOPIPE.EXE “VERTICAL HEATER SPOOLS.DAT" /s /l /n /b /y

Switches Description/s Perform a static analysis./l Create the model input listing (*.RPT)./n Perform a flange analysis./b Create the batch report file (*.OUT).

Page 58: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Interoperability

Page 59: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

59 | WWW.BENTLEY.COM

AutoPIPE Product – Interoperability Matrix

ProjectWise

STAAD AutoPLANT

PlantSpace

OpenPlant

ADLPipe

WinNOZL

PlantFLOW

PULS

AutoPIPE

Caesar SP3D PDS PDMS CADWorx

SolidWorks

Inventor CATIA ME101

AutoPIPE

Bentley Products

3rd Party Products

CAD Products

59

Page 60: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

60 | WWW.BENTLEY.COM

• Improved Caesar 2011 (v5.3) compatibility

• Importing more PCF Component Data

• Improved Roundtrip with AutoPLANT

Interoperability & Import /Export

AutoPIPE

Page 61: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

61 | WWW.BENTLEY.COM

Hot Clash Detection

Page 62: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

62 | WWW.BENTLEY.COM

Using AutoPIPE & Navigator Hot Clash DetectionAutomatic Conversion from Y-Vertical to CAD Z Vertical axis

AutoPIPE MicroStation

Page 63: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

63 | WWW.BENTLEY.COM

Bentley Navigator or MicroStation

Using AutoPIPE & Navigator Hot Clash DetectionTo Avoid Design Mistakes and Operation Failure

Page 64: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

64 | WWW.BENTLEY.COM

Caesar has no Flange component – AutoPIPE now has smart logic to Convert Caesar RIGID Element to intelligent flanges in AutoPIPE with Flange Spec, Flange Type and Pressure Rating

Valve = RIGID Element

Flange = RIGID Element

Flange = RIGID Element

New Smart Flange Conversion from Caesar

Page 65: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

65 | WWW.BENTLEY.COM

Smart Caesar Flange Import

V9.4 : CII Flange -> Valve

• Flange Size• Flange Type • Flange Rating• Flange Spec

V9.5 : Intelligent Flange Conversion

Page 66: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

AutoPLANT / AutoPIPE Integration

Page 67: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

67 | WWW.BENTLEY.COM

New Intelligent AutoPLANT / AutoPIPEPXF Supports Exchange – v9.4

~ 60 Supports

AutoPLANT

AutoPIPE

~ 60 Supports

Page 68: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

68 | WWW.BENTLEY.COM

New Intelligent AutoPLANT / AutoPIPEFlange Exchange – v9.5

Flange type, Flange length, rating, weight, weld connection, gaskets, bolts

New Flange CAD Length

AutoPLANT

AutoPIPE

Page 69: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

69 | WWW.BENTLEY.COM

PXF / PCF 2-Point Flange Component

Weldneck Flange GraphicAutoPLANT orPCF Formats from SmartPlant, CADWorx, AutoDesk or SolidWorks

AutoPIPE

Actual CAD Flange Length imported

Page 70: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

70 | WWW.BENTLEY.COM

PCF Line Number & Class now Imported

Page 71: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

71 | WWW.BENTLEY.COM

PCF Components now Imported

Flexible Joint

Cross

Page 72: AutoPIPE_v9.5_SS4c-highres

© 20

11 B

entle

y Sys

tems,

Incor

pora

ted

72 | WWW.BENTLEY.COM

Import AutoDesk Plant 3D Models

Page 73: AutoPIPE_v9.5_SS4c-highres

© 2

011

Ben

tley

Sys

tem

s, I

ncor

pora

ted

Thank you