Summary… • New AutoPIPE V8i SELECTseries3 (v9.4.0.x)
• Release date, October 2011
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
3 | WWW.BENTLEY.COM
Equipment CheckPumps, Turbines,
Compressors
Iso’s Marked-UpStressISO
Design Report3D
Model
Third Party Programs
Vessel Design
Transient Flow
Analysis
FEAPlantFLOWFluid Flow Analysis
PULSPulsation Analysis
AutoPIPE NozzleNozzle/Vessel Limits
AutoPIPEPipe Stress Analysis
STAADStructural Analysis
AutoPLANT, PlantSpace, SP3D, PDS, PDMS
3D Modeling
NavigatorHot Clash Detection
3D Model
PlantWiseConceptual 3D
Design
PIDFEED
ProjectWiseProject
Management
DigitalPlant – Pipe Stress Analysis WorkFlow PIDFEED
Flange Check
Pipe Support Vendor
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
4 | WWW.BENTLEY.COM
AutoPIPE V8i SS3 (v9.4) Enhancements
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
5 | WWW.BENTLEY.COM
Piping Codes: 2010B31.1, B31.8, B31.3 & EN13480Russian SNIP 2.05.06-85 Oil & Gas Code
AutoPIPE v9.4 Major HighlightsNew Soil Calculator to
ASCE Rules
New Comprehensive 2010 Flange Design
InteroperabilitySTAAD.Pro & MDB Data, StressISOIntegrated Translators: SmartPlant, PDS, AutoPLANT
New Hot Clash Detection with Major 3D
CAD Systems
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
6 | WWW.BENTLEY.COM
Performance Has Improved!
Large Models Open in less than 2 seconds
Large Models Analyze in less than 20 seconds
Large Models Sorted Stresses in less than 5 seconds
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
7 | WWW.BENTLEY.COM
Some Additional Highlights Intelligent PXF pipe support exchange with AutoPLANT Manage Pipe line class data, Valve and Flange tags, show pipe insulation Improved file open and modeling performance Allow Reference points to be defined for any Rotating Equipment Option in Result menu > "Show Lift-off Supports" Export reference point loads to AutoPIPE Nozzle Add a dialog to map AutoPIPE components fields with pcf attributes Thumbnail previews (Vista & Win7) and File Archive / Restore Customized StressISO Data tables and more plotting options Easy troubleshooting non-linear non-convergence Automatic multiple static analysis sets for all piping codes Import custom load combinations from any AutoPIPE model New distribution loads, Static & Member Seismic factors & Reference Point grids Comprehensive Center of Gravity report and graphic plot PIPELINK: Automatic Vertical Support Connections
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
8 | WWW.BENTLEY.COM
Thumbnail Model Previews
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
9 | WWW.BENTLEY.COM
ZIP Archive & Restore Complete ModelArchive (*.ARC) the DAT file, input, result, report, unit and library files (This is a ZIP file)
Input Result Reports Unit Lib.DAT.CMB.XML.FLT.TTC.TTP.TTI.TPP.GDL.TIH.THL.SPC.FS1.HMF.PWS
.MDB
.RSP
.SAM
.HGR
.STS
.FSP
.TIM
.HRM
.FLX
.EIG
.MOD
.ENV
.OPL
.L*
.LOG
.TSS
.TTO
.TDL
.TSM
.TSM
.RPT
.BAK
.CHK
.OUT
.SUM
.TXT
.UNT .LIB
More than 40 Files
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Design Codes
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
11 | WWW.BENTLEY.COM
• ASME B31.1 2010 (Power piping code), Back B31.3 : 2004 • ASME B31.3 2010 (Process Piping)• ASME B31.8 2010 (Gas Transmission Piping)• EN13480 :2010• ASME NB/NC/ND : 2007 (Nuclear piping code)
Piping Codes
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
12 | WWW.BENTLEY.COM
ASME B31.3 : 2010 Changes
Corroded thickness is used in stress calculations Axial force and torsion are included. Sustained SIF is 0.75*I but >= 1.0
Seismic and Wind SIF’s
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
13 | WWW.BENTLEY.COM
ASME B31.3 : 2010 Appendix P Changes
New Stress Allowables
Range Reduction Factor f <= 1.0
Operating Stress Category
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
14 | WWW.BENTLEY.COM
• B31.3:2008 removed application of circumferential weld ‘W’ factor but some companies requested to use it.
Enable Circum. Weld ‘W’ factor for B31.3-2008 and B31.1-2009 codes
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
15 | WWW.BENTLEY.COM
• Applies to B31.1 and B31.3 only
New Option “Use Nominal for Hoop Stress”
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
16 | WWW.BENTLEY.COM
• Applies to B31.1, B31.3 and EN13480 only.
New Option “Use Min. Sustained Margin”Use Coincident pressure /temperature conditions e.g. High Temp /Low pressure De-Coking Process
Consistent
Minimum
Extra 14,000psiAllowable
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
17 | WWW.BENTLEY.COM
• Russian SNIP 2.05.06-85 Oil & Gas Code• Russian Component And Material Libraries
Russian SNIP Code
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
18 | WWW.BENTLEY.COM
• Automated SNIP Soil Data for Seismic Calculations
Russian SNIP Code
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Analysis
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
20 | WWW.BENTLEY.COM
Troubleshooting Non-Linear Non-Convergence
• Support Location• Load Case• Magnitude of Error
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
21 | WWW.BENTLEY.COM
Thermal Bowing by Segment
Partially Hot Filled Pipe
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
22 | WWW.BENTLEY.COM
Customized Analysis SetsBy Hot Modulus and Pressure Stiffening
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Post Processing
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
24 | WWW.BENTLEY.COM
Show Support LIFT-OFF
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
25 | WWW.BENTLEY.COM
Manufacturer Allowable Factors Pumps (API610), Turbines (NEMA SM23) and Compressors (API 617)
Apply
MFG Multiplier
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
26 | WWW.BENTLEY.COM
Manufacturer Allowable Factors Pumps (API610), Turbines (NEMA SM23) and Compressors (API 617)
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
27 | WWW.BENTLEY.COM
Rotating Equipment (Pump, Turbine, Compressor, User)Any point in the model can now be evaluated for Rotating EquipmentUsing Reference Points. This allows modeling the equipment in the system e.g. pump between suction and discharge linesAdvantage: Pump thermal expansion automatically included
Pump Base
SuctionDischarge
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
28 | WWW.BENTLEY.COM
Rotating Equipment (Pump, Turbine, Compressor, User)Any point in the model can be evaluated for Rotating Equipmentincluding anchors. Simply define a Reference Point
Anchor or Reference Point
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
29 | WWW.BENTLEY.COM
• Import User Combinations from Existing or Template Model
Load Combination Templates
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
30 | WWW.BENTLEY.COM
• Combinations can be defined in other combinations but often are not printed. To reduce the clutter they can be hidden.
Load Combinations – Hide Non-Printed
Only Printed code or non-code combinations are shown
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Modeling
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
32 | WWW.BENTLEY.COM
Automatic Modeling Design Checks
Missing Flanges, Duplicate Xtra Data or Supports, Missing Support when Displacement defined
To Assist New and Experienced Pipe Stress Engineers. AutoPIPE scans & reports modeling mistakes
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
33 | WWW.BENTLEY.COM
Show Center of Gravity
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
34 | WWW.BENTLEY.COM
Show Center of GravityCOG Recalculated ‘On-the-Fly’ for Visible Segments / Beams only
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
35 | WWW.BENTLEY.COM
Center of Gravity Detailed Report
Detailed Center of Gravity report including for Beams and individual components, lining Cladding, contents etc.
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
36 | WWW.BENTLEY.COM
Automatic Flange Insertion
Flanged Valves and Flexible Joints
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
37 | WWW.BENTLEY.COM
Show Thermal Anchor Movements
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
38 | WWW.BENTLEY.COM
Hide Structure with One Click
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
39 | WWW.BENTLEY.COM
Show Pipe Insulation
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
40 | WWW.BENTLEY.COM
Select Connected Segments• Review Connectivity • Isolate & Design on Connected Segments• Generate StressISO for Connected Segments
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
41 | WWW.BENTLEY.COM
Flange Bolt/Nut Weight Factor
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
42 | WWW.BENTLEY.COM
Pipe Insulation Cladding
Insulation
Cladding
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
43 | WWW.BENTLEY.COM
New Ball Valve library
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
44 | WWW.BENTLEY.COM
Pipe Line Class
Pipe Line Class imported from CAD
Pipe Line Class mapped from PCF
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
45 | WWW.BENTLEY.COM
Find Point by Coordinates
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
46 | WWW.BENTLEY.COM
Fatigue Range Reduction Factor by material
Input
Output
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Automatic Soil Calculator
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
48 | WWW.BENTLEY.COM
New Automatic Soil Calculator
Click to use Automatic Soil Calculator
ASCE 2005 / AutoPIPE or User defined Methods
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
49 | WWW.BENTLEY.COM
New Automatic Soil Calculator
• ASCE / AutoPIPE / User Methods• Range Of Soil Conditions (High, Low,
Average)• 5 Standard Soil Types• Horizontal or Vertical Pipes
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
50 | WWW.BENTLEY.COM
Soil Calculator – Soil Analysis Studies
Easy to Evaluate DifferentSoil conditions Using STATIC
Multiple Analysis Sets
Important : Evaluate a Range of SOIL Conditions (Dry to Wet)
And Evaluate DifferentSoil conditions for Dynamic Analysis
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
51 | WWW.BENTLEY.COM
Soil Calculator – Soil Spacing Calculations
Dependent on pipe size and operating temperature and
pressure
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
52 | WWW.BENTLEY.COM
Input Grids : New Reference Point
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
53 | WWW.BENTLEY.COM
Input Grids : Static & Member Earthquake Factors
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
54 | WWW.BENTLEY.COM
Input Grids : New Distributed Load
Distribution loads are calculated for inserted or deleted
intermediate points
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
55 | WWW.BENTLEY.COM
Input Grids : Offshore Hydrodynamic Data
Edit and Make Global Changes to the Subsea Mass, Drag and Lift
Coefficients
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
56 | WWW.BENTLEY.COM
Valve and Flange Tags
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
57 | WWW.BENTLEY.COM
Convert Time History to Response Spectrum
0
2
4
6
8
10
12
14
16
18
0 10 20 30 40 50
Dis
pla
cem
ent,
in
Frequency, Hz
Displacement Response Spectrum
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
New Comprehensive Flange Analysis & Design Module
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
59 | WWW.BENTLEY.COM
Flange Analysis & Design Module• Flange Checks to ASME VIII Div 1 & 2 : 2010, ASME III
Appendix XI and ASME III NC 3658.1 (b) (ANSI check)• Material to ASME II, B31.1 or B31.3
• Fast on-screen maximum ratio results with summary notes
• Define Flange data ONCE and duplicate to other same flange types
• Analyze ALL or 1 Flange in Whole Model
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
60 | WWW.BENTLEY.COM
Flange Analysis & Design Module• Hide Duplicate Flanges at Same point
• 2nd B01 Flange not Shown
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
61 | WWW.BENTLEY.COM
Flange Analysis & Design Module• Filter on Visible Segments
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
62 | WWW.BENTLEY.COM
Flange Module – LOADS
• Filter on a specific Operating Case
• Filter on Maximum Pressure and/or Temperature across all Operating Cases
• Filter on a specific load combination
• Filter on Maximum Loads across all Load Combinations
• Ignore Loads or Consider Loads for Div1 or Div 2
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
63 | WWW.BENTLEY.COM
Flange Module – Comprehensive Reports• Inputs & Design Criteria• Detailed Flange
Calculations• Summary Results at
Operating and Gasket Seating Conditions
• Flange Leakage Criteria
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
64 | WWW.BENTLEY.COM
Flange Module – Comprehensive Material & Dimensional Libraries
• Filter by Section Type• Filter by Material Type• Select by Design Code
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
65 | WWW.BENTLEY.COM
Flange Module – Flange Properties
• Flange Material• Standard Flange
Dimensions – ANSI B16.5 or DIN
• Detailed Sketches• Override Data
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
66 | WWW.BENTLEY.COM
Flange Module – BOLT Properties
• Bolt Material Library• Standard Bolt Sizes &
Dimensions – ANSI B16.5 or DIN
• Override Data
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
67 | WWW.BENTLEY.COM
Flange Module – Gasket Properties
• Gasket Materials Built-In• Standard Gasket Dimensions &
Configurations to ASME VIII• Detailed Sketches• Override Data or let program
automatically calculate suitable Gasket
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
68 | WWW.BENTLEY.COM
Flange Module – PIPE Properties
• Comprehensive Pipe Material Library
• Pipe Allowable Stress included in Longitudinal Hub Allowable stress
• Override Allowables
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
StressISO Improvements
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
70 | WWW.BENTLEY.COM
StressISO – Edit Data Tables
Edit Data Tables before Isometrics are generated
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
71 | WWW.BENTLEY.COM
StressISO – Cut Short & Bend Data
Bend Radius, type and thickness (if different to matching pipe)
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
72 | WWW.BENTLEY.COM
StressISO – Break Points & Positioning
• 50 Break Points• Locate North Arrow and Drawing No.
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
Interoperability
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
74 | WWW.BENTLEY.COM
AutoPIPE Product – Interoperability Matrix
ProjectWise
STAAD AutoPLANT
PlantSpace
OpenPlant
ADLPipe
WinNOZL
PlantFLOW
PULS
AutoPIPE
Caesar SP3D PDS PDMS CADWorx
SolidWorks
Inventor CATIA ME101
AutoPIPE
Bentley Products
3rd Party Products
CAD Products
74
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
75 | WWW.BENTLEY.COM
• Caesar 2011 (v5.3) compatibility
• Importing more & more 3D models from e.g. SolidWorks, Inventor, CATIA etc
Interoperability & Import /Export
AutoPIPE
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
76 | WWW.BENTLEY.COM
STAAD.Pro / AutoPIPE Integration Automatic Vertical Support Connections
Vertical Up Connection Vertical Down Connection
Vertical Only Connections for any type of Selected Support
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
77 | WWW.BENTLEY.COM
Export Reference Point Loads to AutoPIPE NozzleAny AutoPIPE Loads can now be Exported AutoPIPE Nozzzle
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
78 | WWW.BENTLEY.COM
PCF CAD Mapping
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
79 | WWW.BENTLEY.COM
• UCI (Universal component Identifier) tag is managed to track component changes e.g. in SmartPlant 3D
Read/Write PCF Component Identifier
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
New AutoPIPE / Navigator Hot Clash Detection
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
81 | WWW.BENTLEY.COM
Using AutoPIPE & Navigator Hot Clash DetectionTo Avoid Design Mistakes and Operation Failure
AutoPIPE
Bentley Navigator
Soft & Hard Clashes between Vessels, Piping (Insulated or
Non-Insulated), Structure, Electrical, Equipment etc.
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
82 | WWW.BENTLEY.COM
AutoPIPE(JSpace)
I-Model Composer(JSM -> DGN)
Bentley Navigator
(DGN Hot Clash)
Hot Clash Detection Phase 2AutoPIPE writes i-model DGN
Phase 1AutoPIPE writes JSpace model ((Deflected & Undeflected)
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
83 | WWW.BENTLEY.COM
AutoPIPE
Using AutoPIPE & Navigator Hot Clash DetectionTo Avoid Design Mistakes and Operation Failure
Hot Clash Tutorial available with program
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
84 | WWW.BENTLEY.COM
Using AutoPIPE & Navigator Hot Clash DetectionTo Avoid Design Mistakes and Operation Failure
Original Light Blue Centerline
Blue Insulated Pipe
Levels/Layers by Line Number or Segment, Insulated or Non-Insulated Deflected Pipes, Deflected Structure, pipe centerline
Deflected Pipe
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
85 | WWW.BENTLEY.COM
Bentley NavigatorCreate Markups and Save to PDF
Using AutoPIPE & Navigator Hot Clash DetectionTo Avoid Design Mistakes and Operation Failure
© 2
011
Ben
tley
Sys
tem
s, I
ncor
pora
ted
AutoPLANT / AutoPIPE Integration
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
87 | WWW.BENTLEY.COM
New intelligent AutoPLANT / AutoPIPE PXF Supports Exchange
~ 60 Supports
9 Supports
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
88 | WWW.BENTLEY.COM
Pre - AutoPIPE 9.4
AutoPIPE
PXFPXF
AutoPLANT
AutoPLANT
Generic Supports imported backLoss of intelligent class data & types
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
89 | WWW.BENTLEY.COM
AutoPIPE 9.4.0.x
AutoPIPE
PXFPXF
AutoPLANT
AutoPLANT
Intelligent Support class data imported back
© 20
11 B
entle
y Sys
tems,
Incor
pora
ted
90 | WWW.BENTLEY.COM
AutoPIPE 9.4.0 PXF Supports
AutoPIPE
AutoPLANT
Intelligent Support class data imported back to AutoPLANT after roundtrip