SIMATIC Software industrial SIMATIC Maintenance Station 2007
Automation and Drives Drive ES Guided Tour Intern Edition 01/02 Drive ES SIMATIC To start, a couple...
-
Upload
michelle-west -
Category
Documents
-
view
216 -
download
1
Transcript of Automation and Drives Drive ES Guided Tour Intern Edition 01/02 Drive ES SIMATIC To start, a couple...
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
To start, a couple of words as to how Drive ES SIMATIC is integrated into the product environment.
Drive ES Basic
Drive ES PCS7
CFC V 5.1(Prerequisite for Drive ES Graphic)
Drive ESGraphic
Drive ES SIMATIC
Communications Engineering/commissioning
Product position:Drive ES SIMATIC is a function block library which supports you when establishing communications between the CPU and drives. The function blocks run on a SIMATIC-CPU.
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
SIMATIC
S7
Drive ES SIMATIC: The Drive ES SIMATIC blocks are configured on a PC and then downloaded into the CPU.
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
Drive ES SIMATIC:Blocks are provided for communication
functions. These blocks do not have to be developed or programmed - they only have to be parameterized. The following blocks are available:
SIMATIC
S7
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
SIMATIC
S7
Blocks: Cyclic data transferNon-cyclic parameter transferReading-out fault texts from drives (e.g. for OP display)Project examplesGenerator to easily expand the communicationsDownload from the CPU (when replacing drives)Converter from parameter set > DB (when replacing drive units)Converter for projects from older blocks into Drive ES SIMATIC format.Tested blocks are available in five languagesBlocks are multi-instance capableBlocks can also be configured with CFC
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
Using project examples: This is how you can use project examples to quickly establish communications between the CPU and your drives.
1. Own project NEW
2. Project example
SIMATIC
S7
Download into the
CPU
Copy
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATICExpanding project examples: You can simply expand the project example using the data block generator.
1. Own project NEW
SIMATIC
S7Download into CPU
Copy
3. Expand hardware
4. Start DB generator
5. Expand STEP7 program
2. Project example
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
2. Set the PROFIBUS
address at the new drive unit
Replacing drives: Here, you can see how the parameter set of the drive is downloaded from the CPU after a drive has been replaced.
SIEMENS
6SE7016-1EA30
WR 2,2 kW
Ooliver. 467321
SIMOVERT SC
SIMATIC
S7
1. Replace the defective drive unit
F 1
F 3
F 5
F 7
F 9
F 1 1
F 2
F 4
F 6
F 8
F 1 0
F 1 2
F 1 4 F 1 5 F 1 6 F 1 7 F 1 8 F 1 9 F 2 0
K 3 K 4 K 5 K 6 K 7 K 8
K 1 1 K 1 2 K 1 3 K 1 4 K 1 5 K 1 6
K 1 K 2
K 1 0K 9
0
2
5
8
3
6
9
.
1
4
7
+ /-+
-
*
/
A - Z
D E L
IN S
A C E GB D F H
I K M OJ L N P
Q S U WR T V X
Y : = (Z \ , )
T A B
A L T
CT R L
S H IF T
A -Z
K H
F13
PROCES S FIELD BUS
SIEMENS
6SE7016-1EA30
WR 2,2 kW
Ooliver. 467321
SIMOVERT SC
replace device
3. Download parameters after the drive has been replaced, e.g. activated
via OP
STEP7 program – download DBs into the
load memory
4. The download FB transfers all of the
parameters from the download DB(s)
Automation and Drives
Drive ESGuided Tour
Intern Edition 01/02
Drive ES SIMATIC
Replacing drives: Here, you can see how a parameter set in a data block is converted for “download from the CPU“.
Save the STEP7 program with generated DB in the
SIMATIC CPU
After start-up has been completed, upread the parameters from the
drive
F 1
F 3
F 5
F 7
F 9
F 1 1
F 2
F 4
F 6
F 8
F 1 0
F 1 2
F 1 4 F 1 5 F 1 6 F 1 7 F 1 8 F 1 9 F 2 0
K 3 K 4 K 5 K 6 K 7 K 8
K 1 1 K 1 2 K 1 3 K 1 4 K 1 5 K 1 6
K 1 K 2
K 1 0K 9
0
2
5
8
3
6
9
.
1
4
7
+ /-+
-
*
/
A - Z
D E LINS
A C E GB D F H
I K M OJ L N P
Q S U WR T V X
Y : = (Z \ , )
TAB
ALT
CTR L
S H IF T
A -Z
K H
F13
SIMATIC
S7