Automated Precision Weighing - mt.com · Smart Load-Cell Technology The load cell, with Monobloc...
Transcript of Automated Precision Weighing - mt.com · Smart Load-Cell Technology The load cell, with Monobloc...
Smart Load-Cell TechnologyThe load cell, with Monobloc technology, is at the core of the SLF6-Series load cells and guarantees the highest preci-sion and reliability. A robust load cell housing features integrated overload protection and durable mechanical interfaces. This ensures stable weight values for many years of intensive use.
High ResolutionSLF6 load cells have a resolution up to 750`000 points. With this high precision, it is possible to measure even the slightest change in the weight; thus unnecessary waste can be minimized and cost savings realized by optimizing the material quantity.
Connect to PLCAll load cells can easily be connected to popular fieldbus systems. Add-on soft-ware modules facilitate seamless inte-gration into automated environment. This allows machine builders to standardize on SLF6-Series load cells for weighing connected to PLC systems.
SLF6-Series Load CellsAccurate – Reliable – Robust – Versatile
With capacities of 6, 15, 32 and 64 kilograms, it is suitable for a variety of applications and industries. These load cells form a compact solution for integration into machines or instruments, and can support various applications with an industry-leading accuracy.
The SLF6-Series load cells provide benefits such as: • 750`000 points of resolution• Directly connects to control systems• Increases speed of filling processes with up to 92 updates per second• For safe as well as hazardous areas (Category 2 and Category 3)• IP66/IP68 Ingress Protection• Minimizes downtimes by checking the platform periodically with the internal weight
Designed for AutomationHigh Precision Load Cells
Hazardous EnvironmentsWhen working in a hazardous environ-ment, safety is key. The SLF6-Series load cells are approved for the use in hazardous areas for Category 2 and Category 3 for top performance in gas-eous and dusty environments.
Auto
mat
ed P
reci
sion
Wei
ghin
g
2METTLER TOLEDO SLF6-Series Load Cells
Auto
mat
ed P
reci
sion
Wei
ghin
g
Parameter Unit SLF606 SLF615 SLF630 SLF660
Load Cell Dimensions [LxWxH] mm 237 x 180.5 x 87.4
Maximum capacity kg 6 15 32 64
Preload range kg 1.08 2.7 5.4 10.8
Readability g 0.01 0.02 0.05 0.1
Repeatability s (at max. load)* g 0.01 0.02 0.05 0.1
Linearity deviation (at half load)* g 0.04 0.08 0.2 0.4* At room temperature and stable environmental conditions without vibration and draft, with automated weight placement
Degree of protection IP66/68
Material of housing Stainless steel (AISI304), brushed, e-polished
Permissible temperature range -20°C to + 60 °C in operation / -20°C to + 70 °C for storage
Data transmission rate Up to 92 update values per second
Tare & zero setting range Full weighing range
Data interfacesRS232, RS422/RS485 / MT-SICS command set / Fieldbus interfaces available as accessories (Profibus DP, DeviceNet, Ethernet/IP, Profinet IO and CC-Link)
Power supply12-24 volt nominal range (10-29 V DC) (standard & Cat. 3) Via APS768x: 120 / 230 V AC, 160 mA (Cat. 2)
Electrical connection M12 connector,12 pins (standard & Cat. 3), M12 connector, 6 pins (Cat. 2)
Warm up time Typically 30 minutes
Model Specific Data
General Specifications
Hazardous Zone Approval Type Approval
Category 2
ATEXII 2 G Ex ib IIC T4 Gb II 2 D Ex ib IIIC T55°C Db -10°C ≤ Tamb ≤ +40°C
IECExEx ib IIC T4 Gb Ex ib IIIC T55°C Db -10°C ≤ Tamb ≤ +40°C
Category 3
ATEXII 3G Ex nA IIC T6 Gc II 3D Ex tc IIIC T60°C Dc -10°C ≤ Ta ≤ +40°C
IECExEx nA IIC T6 Gc Ex tc IIIC T60°C Dc -10°C ≤ Ta ≤ +40°C
3 METTLER TOLEDO SLF6-Series Load Cells
Drawings
30.4
12.75
29.75
8768
252
35°
222.75
237
202.3
180.5
155.8
34.19
131
95
30.4
12.75
29.75
8768
252
35°
222.75
237
202.3
180.5
155.8
34.19
131
95
30.4
12.75
29.75
8768
252
35°
222.75
237
202.3
180.5
155.8
34.19
131
95
4METTLER TOLEDO SLF6-Series Load Cells
Typical Configurations
Standard
1
2 4
7
6
8
9
5
3
No. Item Item Number(s)
1 SLF6 Series Load Cell (Standard) See order information
2 Connection cable
See accessories3 ConBlock or ConBlock IP66
4 Fieldbus Module
5 Fieldbus connection cable
6 Fieldbus cable to PLC
3rd party product7 PLC
8 PC (for service & configuration purpose)
9 Standard RS232 cable
Available from METTLER TOLEDO
Third party product
5 METTLER TOLEDO SLF6-Series Load Cells
Category 3
Safe AreaHazardous Area
1
24
7
6
8
9
1011 5
3
No. Item Item Number(s)
1 SLF6 Series Load Cell (Cat. 3) See order information
2 Connection cable
See accessories3 ConBlock-X
4 Fieldbus Module
5 Fieldbus connection cable
6 Fieldbus cable to PLC
3rd party product
7 PLC
8 PC (for service & configuration purpose)
9 Standard RS232 cable
10 Safety barrier / isolator
11 Data cable (RS232 or RS422/RS485)
Available from METTLER TOLEDO
Third party product
6METTLER TOLEDO SLF6-Series Load Cells
Category 2
Safe Area
1
24 7
9
10
11
5
12
6
6 8
9
3Hazardous Area
No. Item Description Item number(s)
1SLF6 Series Load Cell (Cat. 2)
Load cell for Cat. 2 See order information
2 Ex-i cableCable M12, 6 Pin - 10/20 m Ex1 cable for Cat. 2
See accessories
3 APS768x Power supply unit for hazardous area
See accessories
4Ex-i cable, 4 pin, 10 m for Cat. 2
Included in the scope of delivery of ACM200
5 ACM200 Interface converter in the safe area
6 Data cable RS232 : fix connected to ACM200, length: 10 m RS422/485: data cable has to be defined by the user
7 Gender Changer M-to-M gender changer 3rd party product
8 RS232 cable M-to-M 11601007
9 Fieldbus module Different versions are available See accessories
10 Fieldbus cable Customer cable
3rd party product11 PLC
12 PC or Laptop For service or configuration purposes
Available from METTLER TOLEDO
Third party product
7 METTLER TOLEDO SLF6-Series Load Cells
Standard &Category 3
Order Number
Designation Description Picture
30244446 Cable M12 12Pin - open leads 10m Cable for safe area
30244447 Cable M12 12Pin - open leads 10m Cable for Hazardous area (Cat. 3)
11152000 ConBlock Connection Module
30092965 ConBlock IP66Connection module with IP66 housing
30374066 ConBlock-XConnection Module for Cat. 3ATEX: II 2G Ex eb IIC T6 Gb II2D Ex tb IIC T 85°C Db
42102809 Profibus Module
Incl. connection cable for configuration
42102859 Profinet Module
42102810 DeviceNet Module
41102860 Ethernet IP Module
30038775 CC-Link Module
11141979 Fieldbus connection cable 1 m D-Sub 9 male – open leads
Accessories
Order Information
Model Version Item Number
SLF606
Standard 30263711Cat. 2 30373339Cat. 3 30364213
SLF615
Standard 30263712Cat. 2 30373367Cat. 3 30364214
SLF630
Standard 30263713Cat. 2 30373368Cat. 3 30364215
SLF660
Standard 30263714Cat. 2 30373369Cat. 3 30364216
Scope of Delivery:
• Load Cell • User Manual• Declaration of Conformity
Mettler-Toledo GmbHIndustrial DivisionCH-8606 Nänikon, SwitzerlandTel. + 41 44 944 22 11
Local contact: www.mt.com/contacts
Subject to technical changes© 01/2017 Mettler-Toledo GmbHMTSI 30321521
www.mt.com/SLF6For more information
Category 2
Order Number
Designation Description Picture
30267190 Cable M12 6 Pin – 10m Ex1 Cable for hazardous area (Cat. 2) for connection between load cell and APS768x30337109 Cable M12 6 Pin – 20m Ex1
20026724 APS768x power supply (120 V AC)Power supply unit in hazardous area
20026728 APS768x power supply (230 V AC)
22026695 AC supply / RS232
ACM200 Interface converter (CL to serial) in safe area
22026696 AC supply / RS422, RS485
22026692 DC supply / RS232
22026693 DC supply / RS422, RS485
22016791Longer Ex-i cable, 4 pin (up to 100 m) for Cat. 2
For connection betwwen APS768x and ACM200
Accessories
Convenient Service Tool Speeds up Commissioning
The APW-Link™ PC based software can be used for simple configuration purposes. The following operations can be performed: • Configuration of weighing parameters• Optimization of filter settings• Calibration & adjustment • Observe weighing data on a graph and export to a spreadsheet for further processing
www.mt.com/apw-link