Auto call setup for xcal series 3.x.xx e mail

6
XCAL series Guide for Auto Call Setting for E-MAIL Test Version 3.X.XX 2008-3-11

Transcript of Auto call setup for xcal series 3.x.xx e mail

Page 1: Auto call setup for xcal series 3.x.xx e mail

XCAL series

Guide for Auto Call

Setting for E-MAIL Test

Version 3.X.XX

2008-3-11

Page 2: Auto call setup for xcal series 3.x.xx e mail

XCAL series AutoCall Setting E-Mail Test

Unit 206, 2/F., No. 8 Science Park West Avenue Page 2 Hong Kong Science Park, Shatin, Couei APAC Ltd New Territories, Hong Kong www.couei.com TEL: +852-2210-7004

1 Start AutoCall Scenario Settings

Figure 1.1: AutoCall Scenario Settings window

Alias List List of created scenarios (Call Scripts)

AutoCall Scenario Scenarios selected among the Alias list to be used during the current auto call automation session.

Left Click

Page 3: Auto call setup for xcal series 3.x.xx e mail

XCAL series AutoCall Setting E-Mail Test

Unit 206, 2/F., No. 8 Science Park West Avenue Page 3 Hong Kong Science Park, Shatin, Couei APAC Ltd New Territories, Hong Kong www.couei.com TEL: +852-2210-7004

2 Make a New E-MAIL Script (Create New Scenario)

Figure 2.1 : AutoCall Setup window for a new call script

(1) Designate E-MAIL Connection Information and Call Timers

Figure 2.2 : Example of designate E-MAIL connection info and call timers

Left click Left click click to select E-mail Script window

12

3

5

4

Page 4: Auto call setup for xcal series 3.x.xx e mail

XCAL series AutoCall Setting E-Mail Test

Unit 206, 2/F., No. 8 Science Park West Avenue Page 4 Hong Kong Science Park, Shatin, Couei APAC Ltd New Territories, Hong Kong www.couei.com TEL: +852-2210-7004

① Left click to select E-MAIL Script window

② Type any call script name

③ Designate E-MAIL connection

- Tick SMTP (Test SMTP or not, send e-mail)

- Server : 220.241.96.242 (SMTP server address or URL)

- User : test1 (The Account on the above E-MAIL server)

- From : [email protected] (Sender’s E-MAIL Account)

- To : [email protected] (Receiver’s E-mail Account)

- Subject: Test ( E-mail subject, limit within 105 characters)

- Content: test (E-mail content ,limit within 253 characters)

- Tick Attach file (E-mail test inc attach file or not)

Select File Size at combo box(4 size attach file can be chosen, the file is generated by

XCAL-W)

- Tick POP3 (Test POP3 or not, receive e-mail)

- Server : 220.241.96.242 (POP3 server address or URL)

- User ID : test2 (The Account on the POP3 server, the receiver’s account)

- Password: emialtest (password)

- Tick Delete mail

Keep the mail on the POP3 server or not, if the server storage space is limited, then select the

option

④ Designate Call Timers in unit of second

- Idle Time : 5 (seconds, Recommended value)

- Setup Time :30 (second, Air-interface setup time)

- T.Setup Time/Total time (seconds, grey , It is ignored)

- Traffic Time : 120 (seconds)

- Call Count : 100

Traffic Time and Call Count can be changed with your test propose.

Please refer to E-MAIL Call Timers Diagram at next page.

⑤ Click OK to save the configuration

3 Call Timer Idle Time

UE recess interval before start next Call

Page 5: Auto call setup for xcal series 3.x.xx e mail

XCAL series AutoCall Setting E-Mail Test

Unit 206, 2/F., No. 8 Science Park West Avenue Page 5 Hong Kong Science Park, Shatin, Couei APAC Ltd New Territories, Hong Kong www.couei.com TEL: +852-2210-7004

Setup Time Timer for establishment of PPP connection (DUN)

T_Setup Time Timer for logging to a target server (FTP, Ping, HTTP and so forth)

If Timer expires without successful access to the target Call, Traffic Setup Fail will be made in call

result.

Total Setup Time Either “Setup time and Traffic Setup Time” or “Total Setup” time can be defined.

Traffic Time Timer for downloading/uploading a file from/to E-MAIL server or opening target HTTP web site. If

Timer expires without completing downloading/uploading a file from/to E-MAIL server or opening

HTTP web site, Time Out will be made in call result.

In case of Ping Call, it is ignored.

Call Count How many times Call test are performed

Total Time [ms] Total time of a call, i.e. the UE will initiate a new call every Total time in ms, whatever call event has

happened within this time interval. This value has to be larger than the sum of Idle Time, Setup Time

and Traffic Time.

4 Schedule a Call Script

Left Click and Drag & Drop

1

2

3

Page 6: Auto call setup for xcal series 3.x.xx e mail

XCAL series AutoCall Setting E-Mail Test

Unit 206, 2/F., No. 8 Science Park West Avenue Page 6 Hong Kong Science Park, Shatin, Couei APAC Ltd New Territories, Hong Kong www.couei.com TEL: +852-2210-7004

Figure 4.1 : How to schedule a Call Script

① Left click and Drag & Drop Alias List item you want to test. ② Tick ‘All Scenarios’ to get a log file with your call test ③ Click ‘OK’ button to start a call test

5 E-MAIL Call Timers Diagram

Figure 5.2 : E-MAIL Call Timers Diagram