Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and...

4
Australian/NZ and International Standards for Electrical Safety in Healthcare Monday 8 October, 1.45 pm Concurrent Session 4 – Safety, P6 & P7, Plaza Level International Standards for Electrical Safety in Healthcare – IEC60364-7-710, AS/NZS 3003 and AS/NZS 4510 Matthias Schwabe, Bender GmbH / WGKT George Kotenko, CAPTECH Visit us at Booth no. 29

Transcript of Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and...

Page 1: Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and International Standards for Electrical Safety in Healthcare, 1.45 pm el e – IEC60364-7-710,

Australian/NZ and International Standards for Electrical Safety in Healthcare

Monday 8 October, 1.45 pm

Concurrent Session 4 – Safety, P6 & P7, Plaza Level

International Standards for Electrical Safety in Healthcare –

IEC60364-7-710, AS/NZS 3003 and AS/NZS 4510

Matthias Schwabe, Bender GmbH / WGKT

George Kotenko, CAPTECH

Visit us atBooth no. 29

Page 2: Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and International Standards for Electrical Safety in Healthcare, 1.45 pm el e – IEC60364-7-710,

LIM2010AU Line Isolation Monitor (LIM) measures the total (prospective) hazard current (THC) in an isolated AC system.

This product is specifically designed to meet the requirements of AS/NZS stan-dards for Australia and New Zealand.

A specific test module LIM2010AU-T is required to meet those standards.

MK2000CBMAU indicates the status of LIM2010AU visually and audibly.

Solutions acc. to AS/NZS 3003 and AS/NZS 4510

G

< U > A L1

SFC

Main distribution board

LIM

L2

SFC

Operating room

L1

L2

COMTRAXX®

LIM2010AU

STW3

EDS151

MK2430

CP9xx

What can you do in addition to both standards?

Page 3: Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and International Standards for Electrical Safety in Healthcare, 1.45 pm el e – IEC60364-7-710,

■■ CP9xx (clear and advanced) information and visualization for technical and medical staff

■■ EDS151 (fault location) identifi-ying faulty medical devices and equipment online in ICU and OT

■■ Connection to industry standard communication networks incl. Ethernet and Modbus

■■ Testing medical electrical equip-ment acc. to IEC 60601-1, 3rd Edition with UNIMET® 810ST

MK2430 remote alarm indicator and test combination provides fault, alarm and operating messages from the monitoring devices acc. to IEC 60364-7-710 with clear and concise information to medical and technical staff.

ISOMETER® isoMED427P Insulation monitoring for medical IT systems; load and temperature monitoring for medical isolating transformers in OT, ICU and other group 2 locations.

Solutions acc. to IEC 60364-7-710

isoMED427P

COMTRAXX® CP9xx series ISOSCAN® EDS151

UNIMET® 810ST

Page 4: Australian/NZ and International Standards for Electrical ...€¦ · Australian/NZ and International Standards for Electrical Safety in Healthcare, 1.45 pm el e – IEC60364-7-710,

Photos: Thinkstock (© monkeybusinessimages) and Bender Archiv. BENDER Group 2211

en /

09.2

018

/ pdf

/ ©

Ben

der G

mbH

& C

o. K

G, G

erm

any

– Su

bjec

t to

chan

ge! T

he s

peci

fied

stan

dard

s ta

ke in

to a

ccou

nt th

e ed

ition

val

id u

ntil

09.2

018

unle

ss o

ther

wis

e in

dica

ted.

Bender GmbH & Co. KGPostfach 1161 • 35301 Grünberg • GermanyLondorfer Straße 65 • 35305 Grünberg • GermanyTel.: +49 6401 807-0 • Fax: +49 6401 807-259E-Mail: [email protected] • www.bender.de

Captech13/40 Edina Road • Ferntree Gully VIC 3156 • AustraliaTel.: +61 3 9758 5866 • Fax: +61 3 9752 2067E-Mail: [email protected] • www.captech.com.au